ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 · The default IP address of the ETERNUS Manager GUI • Initial Setup ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2
Post on 28-Jul-2018
253 Views
Preview:
Transcript
ETERNUSDX80 S2, DX90 S2,DX410 S2 and DX440 S2
Initial Setup
Copyright Fujitsu Technology Solutions, Release August 2011Initial Setup ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 0
Connect FST to DX80 S2 / DX90 S2 Connect FST to DX400 S2 Initial Configuration of the FST Initial Configuration Web GUI Initial Wizard System Setup Initial Manual Setup
Initial Setup ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 Copyright Fujitsu Technology Solutions, Release August 2011
Content
1
Connect FST to DX80 S2 / DX90 S2DX80 S2 and DX90 S2 systems have one MNT LAN port per
CM The MNT port is shared for both the Field Engineer and customer
administration tasks Connect the LAN cable of the Field Service Terminal (FST) to the port
labeled "MNT" at the Controller Module• The "Master LED" of the respective CM lights in green
Copyright Fujitsu Technology Solutions, Release August 2011Initial Setup ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2
MNT PortMaster LED
2
Connect FST to DX400 S2DX400 S2 systems support a specific FST LAN port per CM Connect the LAN cable of the Field Service Terminal (FST) to the port
labeled "FST" at the Controller Module• The "Master LED" of the respective CM lights in green
Separate LAN port labeled "MNT" at each CM can be connected to the customer LAN Both ports can be used for Field Engineer as well as for customer
administration tasks
Copyright Fujitsu Technology Solutions, Release August 2011Initial Setup ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2
FST PortMaster LED MNT Port
3
Initial Configuration of the FSTConnect the FST to the Master CM of the ETERNUS DX S2
system
The default IP address of the ETERNUS Manager GUI• http://192.168.1.1/
Copyright Fujitsu Technology Solutions, Release August 2011Initial Setup ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2
Web browser Internet Explorer 7.0/8.0 or laterMozilla Firefox 3.6.x or later
LAN cable Straight cable or cross-linked cable (direct connection)
IP Address/Subnet maskETERNUS DX S2 Entry: MNT
ETERNUS DX S2 Midrange: FST
Factory default IP Address: 192.168.1.1Factory Subnet mask: 255.255.255.0
IP address of the FST Select it within the same subnet of IP Address that is used for the ETERNUS LAN Port (For example 192.168.1.20)
Caution Do not use a proxy server or cache (Temporary Internet Files)JavaScript and Style Sheet must be enabled for the browser
4
Initial Configuration Web GUI (1)To start the installation procedure, logon to the ETERNUS
DX S2 Web GUI using the standard User Account User name: root Password: root
Copyright Fujitsu Technology Solutions, Release August 2011Initial Setup ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 5
Initial Configuration Web GUI (2)The opening screen giving a quick overview about the system
directly appears after log-in to the ETERNUS DX S2 Web GUI
Copyright Fujitsu Technology Solutions, Release August 2011Initial Setup ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2
Status overviewof the system
Global overview aboutconfigured disk capacity
Global Systeminformation
6
Indicator Colour DescriptionGreen Each component is in normal status
Orange Component is under maintenance (self test)
YellowPreventive maintenance is required for some components.Pinned data is detected.
RedThis status sign is displayed under the following conditions Component failure is detected Loop Down is detected
Red
This status sign is displayed under the following conditions Abnormal status is detected at power on Abnormal status is detected at power off, the system has not
started up normally Error during restoration of the operating environment at power-
on The system is abnormal
Initial Configuration Web GUI (3)General status information of the ETERNUS DX S2 system
Copyright Fujitsu Technology Solutions, Release August 2011Initial Setup ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 7
Initial Configuration Web GUI (4)Status information of each ETERNUS DX S2 component
Copyright Fujitsu Technology Solutions, Release August 2011Initial Setup ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2
Indicator Colour Description
Green Each component is in normal status
Blue A component is installed but unused
Orange Component is under maintenance (self test)
Yellow Preventive maintenance is required
Red Component failure is detected
8
Initial Wizard System Setup (1)The first Initial Setup Wizard Setup the Storage System Name, Set Date & Time, Change Root
password Feature registration
• Thin Provisioning, Advanced Copy and SED Authentication key Set Network Environment and log out to activate the settings
Copyright Fujitsu Technology Solutions, Release August 2011Initial Setup ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 9
Initial Wizard System Setup (2)The second Initial Setup Wizard session can be started after
the first setup is done and it supports the setup of the notification network components SNMP
• Agent Basics, Manager, Agent User, Agent Community, Agent Trap Notification
• e-Mail and syslog
Copyright Fujitsu Technology Solutions, Release August 2011Initial Setup ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 10
Initial Manual Setup - Date and Time "System" "System Settings" Time, Date and time zone Daylight Saving Time NTP server
Copyright Fujitsu Technology Solutions, Release August 2011Initial Setup ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 11
Initial Manual Setup - Machine NameOptional settings to define system information A self-explanatory name for the ETERNUS DX system A description of the location of the ETERNUS DX installation Contact information of the administrator
Copyright Fujitsu Technology Solutions, Release August 2011Initial Setup ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 12
Initial Manual Setup - Password It is always recommended to change the default passwords
(after customer's approval) It is recommended to setup an additional user account with
appropriate permissions to administrate other user accounts• The user account "f.ce" has per default only the permission to change its own
password• Helps in situations with forgotten passwords
Copyright Fujitsu Technology Solutions, Release August 2011Initial Setup ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 13
Initial Manual Setup - Network Environment IP Address of the Master CM In the event of an Ethernet link error of the Master CM MNT port, the IP
address is taken over automatically by the Slave CM MNT port In a DX400 S2 system it is also possible to setup the network
environment for the FST port
Copyright Fujitsu Technology Solutions, Release August 2011Initial Setup ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2
Allowed IP List• Default Gateway must be set• Defines all servers that are allowed to access the LAN port of the
ETERNUS DX S2 system• Either Host IP Address and Netmask• Or Network Segment Address and Netmask
14
Initial Manual Setup - Firewall SettingThis window allows or denies different TCP/IP management
services that can be used via the LAN ports "MNT is available in DX S2 systems "FST" is available in DX400 S2 systems only "RMT" is used at Fujitsu site only
Copyright Fujitsu Technology Solutions, Release August 2011Initial Setup ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 15
Initial Manual Setup - E-Mail NotificationSetup E-Mail Notification window can be used to define Email notification services Email server settings Email retries
Copyright Fujitsu Technology Solutions, Release August 2011Initial Setup ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 16
Initial Manual Setup - Syslog SettingThis window can be used to define up to two syslog servers Any Unix or Linux server with a running "syslog" daemon in which the
remote collection service is enabled Also any other error collection program that supports the standard syslog
protocol can be used• For example Microsoft Operations Manager (MOM)
Copyright Fujitsu Technology Solutions, Release August 2011Initial Setup ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 17
Initial Manual Setup - SNMP EnvironmentSetup SNMP Interface SNMP is disabled by default SNMP must be enabled for the other SNMP settings to appear in bold
under the "Action" column
Copyright Fujitsu Technology Solutions, Release August 2011Initial Setup ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 18
top related