Energy Auditing Techniques for Small Commercial Facilities 2011 Ryan Stroupe, Pacific Energy Center Jim Kelsey P.E., kW Engineering Sean Harleman, kW Engineering.

Post on 11-Jan-2016

216 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

Transcript

1

Energy Auditing Techniques for Energy Auditing Techniques for Small Commercial FacilitiesSmall Commercial Facilities

20112011

Ryan Stroupe, Pacific Energy CenterJim Kelsey P.E., kW EngineeringSean Harleman, kW EngineeringTodd Bell, Food Service Technology Center

012345678

9/20 9/22 9/24 9/26 9/28 9/30 10/2 10/4

2

Commercial KitchenCommercial KitchenEnergy AuditEnergy Audit

3Energy Auditing Techniques for Small Commercial Facilities

Presentation by:

Todd Bell &Richard Young

4Energy Auditing Techniques for Small Commercial Facilities

5

6

On-line Food Service Toolbox:On-line Food Service Toolbox:

rebate infodesign guides

cost calculatorsseminars

energy tipscontact

information

7Energy Auditing Techniques for Small and Medium Commercial Facilities2009

AgendaAgenda• Introduction

– Learning Objectives– Energy Auditor Role and Activities– Why is Module Topic Important?

• Foundational Concepts

• Energy Efficiency Opportunities

• Reinforcement Activity

• Summary– Resources and References

8Energy Auditing Techniques for Small and Medium Commercial Facilities

Learning ObjectivesLearning Objectives

This food service training section will teach you to:• understand some “basics” about a commercial kitchen• walk into a kitchen and locate potential energy savings• identify efficient food service equipment and rebates

9Energy Auditing Techniques for Small and Medium Commercial Facilities

Energy Auditor Role and ActivitiesEnergy Auditor Role and Activities

The commercial kitchen is an uncomfortable, dangerous and complex environment.

The auditor should be able to:• locate some basic energy savings,•educate the client about future savings,•avoid disrupting the work flow of the kitchen, and•avoid getting hurt!

10Energy Auditing Techniques for Small and Medium Commercial Facilities

Why is Module Topic Important?Why is Module Topic Important?

• Energy Intensive!– about 5 times more watts/sq. ft. than other commercial

• Long Operating hours– 14 to 20 hours a day typical (many are 24 h/day)

• Little or No Planning for Efficiency

• Low Equipment Turnover– appliances are expensive and last 5 to 40 years

• There’s a kitchen in almost every building!

Overview of the Commercial KitchenOverview of the Commercial Kitchen

11Energy Auditing Techniques for Small and Medium Commercial Facilities

Foundational ConceptsFoundational Concepts

An example of the total energy breakdown (BTU) in a full service restaurant.

Where the energy goes:Where the energy goes:

12

Kitchen uses 5 times more energy per square foot than rest of the building!

“Your kitchen is bigger than you realize!”

13Energy Auditing Techniques for Small and Medium Commercial Facilities

Opportunities to Save EnergyOpportunities to Save Energy

• Commercial Kitchen Ventilation– optimization and control

• Cooking Appliances– specifying efficiency

• Water and Water Heating– conservation and efficient operation

14Energy Auditing Techniques for Small and Medium Commercial Facilities

Commercial Kitchen VentilationCommercial Kitchen Ventilation

15Energy Auditing Techniques for Small and Medium Commercial Facilities

Kitchen Ventilation is measured in CFMKitchen Ventilation is measured in CFM

Your hood eats a lot of basketballs!

CFM (cubic feet per minute)CFM (cubic feet per minute)A cubic foot is about the size of a basketball.A cubic foot is about the size of a basketball.

16Energy Auditing Techniques for Small and Medium Commercial Facilities

The GoalThe Goal

Reduce the CFM but still

“capture and contain” the smoke and heat.

The BenefitsThe Benefits• reduced fan energy consumption

• reduced fan kW (lower demand)

• reduced heating and AC energy consumption

– potential gas and electric impact

17Energy Auditing Techniques for Small and Medium Commercial Facilities

Three Starting StrategiesThree Starting Strategies• Rebalance ventilation systems

• requires a professional service• one example resulted in 46% savings or $1,000/year

• Set make-up air duct stat to 55°F• located inside the make-up air duct near the blower.• one large hotel saved $15,000/year!• see the energy tip sheet at:

www.fishnick.com/saveenergy/energytips/tipsheets/natural_gas.pdf

• Turn off hoods when cooking appliances are off.

18Energy Auditing Techniques for Small and Medium Commercial Facilities

Example: Properly Set Duct StatExample: Properly Set Duct Stat

19Energy Auditing Techniques for Small and Medium Commercial Facilities

Resource: On-line Design GuidesResource: On-line Design Guides

20Energy Auditing Techniques for Small and Medium Commercial Facilities

Two NuggetsTwo NuggetsHow to keep the smoke How to keep the smoke and heat in the hood.and heat in the hood.

Optimize the Kitchen Exhaust HoodOptimize the Kitchen Exhaust Hood

21Energy Auditing Techniques for Small and Medium Commercial Facilities

Push Appliances BackPush Appliances Back

22Energy Auditing Techniques for Small and Medium Commercial Facilities

Add Side PanelsAdd Side Panels

23Energy Auditing Techniques for Small and Medium Commercial Facilities

Side Panels in PracticeSide Panels in Practice

24Energy Auditing Techniques for Small and Medium Commercial Facilities

Verifying Capture and ContainmentVerifying Capture and Containment

• Operate all the appliances• Use smoke to visualize spillage• Test front and sides

Once exhaust is optimized, then…

25Energy Auditing Techniques for Small and Medium Commercial Facilities

Consider variable speed drives for Consider variable speed drives for kitchen exhaust and makeup air.kitchen exhaust and makeup air.

26Energy Auditing Techniques for Small and Medium Commercial Facilities

Problem: The kitchen exhaust hood Problem: The kitchen exhaust hood operates at 100%.operates at 100%.

All day long. (And sometimes all night as well.)

Whether you are cooking or not!

27Energy Auditing Techniques for Small and Medium Commercial Facilities

Variable Speed Exhaust Fan Control Variable Speed Exhaust Fan Control “Demand Ventilation”“Demand Ventilation”

optical Sensor

Keypad

temperature Sensor

Rebate!

28Energy Auditing Techniques for Small and Medium Commercial Facilities

Demand Ventilation Savings:Demand Ventilation Savings:

Exhaust and Makeup-Air Fan Energy

Makeup-Air Heating and Cooling

Bonus: Quiet Kitchen!

29Energy Auditing Techniques for Small and Medium Commercial Facilities

Learn how this system works:Learn how this system works:www.melinkcorp.com/intellihood_animation.htmwww.melinkcorp.com/intellihood_animation.htm

30Energy Auditing Techniques for Small and Medium Commercial Facilities

Exhaust and Makeup Air Fan Power

0

2

4

6

8

10

12

14

16

0 2 4 6 8 10 12 14 16 18 20 22Time

Po

wer

(kW

)Design Exhaust Ventilation Rate (cfm) 22,500

Average Fan Power Reduction (kW) 8.70

Yearly Fan Energy Cost Savings ($) 9,910

Yearly Heating and Cooling Energy Cost Savings ($) 9,460

Total Yearly Operating Cost Savings ($) 19,370

DVC System Installed Cost ($) 15,000

Pay Back Period (yrs) 0.8

Calculated using $0.13/kWh, $0.80/therm, operating 365 days per year.

Mark Hopkins HotelMark Hopkins HotelAvg. without

DVC = 14.0 kW

Avg. with DVC = 5.3 kW

31Energy Auditing Techniques for Small and Medium Commercial Facilities

SupermarketSupermarket

Design Exhaust Ventilation Rate (cfm) 23,800

Average Fan Power Reduction (kW) 6.16

Yearly Fan Energy Cost Savings ($) 3,770

Yearly Heating and Cooling Energy Cost Savings ($) 4,990

Total Yearly Operating Cost Savings ($) 9,310

DVC System Installed Cost ($) 18,000

Pay Back Period (yrs) 1.9

Calculated using $0.12/kWh, $1.00/therm, operating 360 days per year.

Exhaust and Makeup AIr Fans

0

2

4

6

8

10

12

14

16

0 2 4 6 8 10 12 14 16 18 20 22

Time

Po

wer

(kW

)

Avg. without DVC = 8.5 kW

Avg. with DVC = 2.3 kW

32Energy Auditing Techniques for Small and Medium Commercial Facilities32

Exhaust and Makeup Air Fan Power

0

2

4

6

8

10

12

14

16

0 2 4 6 8 10 12 14 16 18 20 22Time

Po

wer

(kW

)

U.C. Berkeley U.C. Berkeley Clark Kerr CampusClark Kerr Campus

Design Exhaust Ventilation Rate (cfm) 12,200

Average Fan Power Reduction (kW) 6.98

Yearly Fan Energy Cost Savings ($) 4,100

Yearly Heating and Cooling Energy Cost Savings ($) 2,350

Total Yearly Operating Cost Savings ($) 6,450

DVC System Installed Cost ($) 16,000

Pay Back Period (yrs) 2.5Calculated using $0.115/kWh, $1.00/therm, operating 300 days per year.

Avg. without DVC = 12.7 kW

Avg. with DVC = 5.8 kW

33Energy Auditing Techniques for Small and Medium Commercial Facilities33

Design Exhaust Ventilation Rate (cfm) 6,000

Average Fan Power Reduction (kW) 2.40

Yearly Fan Energy Cost Savings ($) 2,040

Yearly Heating and Cooling Energy Cost Savings ($) 339

Total Yearly Operating Cost Savings ($) 2,380

DVC System Installed Cost ($) 6,000

Pay Back Period (yrs) 2.5

Calculated using $0.13/kWh, operating 365 days per year.

Casual DiningCasual DiningAvg. without

DVC = 14.0 kW

Avg. with DVC = 14.0 kW0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

0 2 4 6 8 10 12 14 16 18 20 22

kW

0

20

40

60

80

100

VS

D (

%)

EF #2 Left EF #1 Right EF-2 VSD EF-1 VSD

5 kWh/ Day

7 kWh/ Day

2.2 kW

62%

34Energy Auditing Techniques for Small and Medium Commercial Facilities

The Outdoor Air-Load CalculatorThe Outdoor Air-Load CalculatorOnline tool for estimating CKV $$Online tool for estimating CKV $$

Inputs• location• operating hours• fan types• static pressureOutputs• heating and cooling BTU• fan energy

352009Energy Auditing Techniques for Small and Medium Commercial Facilities35

36Energy Auditing Techniques for Small and Medium Commercial Facilities

Exhaust Hood LightsExhaust Hood Lights

In this exhaust hood are eleven, 75 watt incandescent light bulbs. Replacing them with 20 watt CFL’s can reduce their energy usage by $500 annually.

16 hrs/day @ $0.15/kWh

37Energy Auditing Techniques for Small and Medium Commercial Facilities

Kitchen: Food PrepKitchen: Food Prep

38Energy Auditing Techniques for Small and Medium Commercial Facilities

Realities of the KitchenRealities of the Kitchen

• Cooking appliances are guzzlers!• Usually not viable to replace working appliance

– hassle, long payback

• But, surveys often preface remodeling!– take advantage of good opportunities

• Appliance failure = panic = poor purchasing – get the right info to the right people early

• Purchasing decisions have long lasting impact!

Bonus: Efficiency = Improved Performance!

39

Resources: how and where to find Resources: how and where to find efficient appliancesefficient appliances

Energy Auditing Techniques for Small and Medium Commercial Facilities

40

Refrigeration FryersHot Holding Cabinets

Steamers

www.energystar.gov/cfswww.energystar.gov/cfs

ENERGY STAR Categories

Ice MachinesDish MachinesGriddles Convection Ovens

41Energy Auditing Techniques for Small and Medium Commercial Facilities

42

California’s Food Service Appliance California’s Food Service Appliance Rebates are a Great Resource!Rebates are a Great Resource!

Energy Auditing Techniques for Small and Medium Commercial Facilities

43

All of the rebated appliances are All of the rebated appliances are energy efficient!energy efficient!

Here’s how to get all the Here’s how to get all the information you need:information you need:

Energy Auditing Techniques for Small and Medium Commercial Facilities

44Energy Auditing Techniques for Small and Medium Commercial Facilities

45Energy Auditing Techniques for Small and Medium Commercial Facilities

46

Complete List of Qualified Products

Updated Regularly

Rebate Amount & Energy Efficiency

Goes beyond ENERGY STAR Energy Auditing Techniques for Small and Medium Commercial Facilities

47

Application Forms Online

Energy Auditing Techniques for Small and Medium Commercial Facilities

48

The rebate list is your The rebate list is your

shopping list.shopping list.

Energy Auditing Techniques for Small and Medium Commercial Facilities

49Energy Auditing Techniques for Small and Medium Commercial Facilities

Example: Two appliances that are Example: Two appliances that are candidates for early change out.candidates for early change out.

50Energy Auditing Techniques for Small and Medium Commercial Facilities

Insulated Insulated Energy StarEnergy StarHot Food Holding CabinetsHot Food Holding Cabinets

Rebate!

51

Tools to determine your energy savings:Tools to determine your energy savings:

52Energy Auditing Techniques for Small and Medium Commercial Facilities

Sample Sample ResultsResults

53Energy Auditing Techniques for Small and Medium Commercial Facilities

Life-Cycle Costs* Life-Cycle Costs* Hot Food Holding CabinetsHot Food Holding Cabinets

*Based on 10¢/kWh, a 5-year life expectancy and a 3.1% discount rate

$2,200$2,200!!

54Energy Auditing Techniques for Small and Medium Commercial Facilities

Un-insulated holding cabinet also adds Un-insulated holding cabinet also adds extra heat load to the room…extra heat load to the room…

…equal to about 10 peopleNo Insulation

55Energy Auditing Techniques for Small and Medium Commercial Facilities

Energy Star Steamer Energy Star Steamer Saves Big on Water and EnergySaves Big on Water and Energy

Rebate!

562009Energy Auditing Techniques for Small and Medium Commercial Facilities56

Boiler Based Steamer (Not ENERGY STAR)

Average Water Usage = 40 gph

57Energy Auditing Techniques for Small and Medium Commercial Facilities

To identify a boiler-based steamerTo identify a boiler-based steamer

Look for:

• dedicated / hard-wired water inlet

• drain pipe to a floor drain– condensate water running down the drain

• sealed / pressurized boiler– “boilerless” has an “atmospheric” steam generator

58Energy Auditing Techniques for Small and Medium Commercial Facilities 58

5- Year Life-Cycle Costs 5- Year Life-Cycle Costs Three-pan Steamer ExampleThree-pan Steamer Example

$11,50$11,500!0!

$65$6500

59Energy Auditing Techniques for Small and Medium Commercial Facilities

Kitchen Sanitation: Hot Water UseKitchen Sanitation: Hot Water Use

602009Energy Auditing Techniques for Small and Medium Commercial Facilities60

61Energy Auditing Techniques for Small and Medium Commercial Facilities

Water Costs Water Costs + Sewer Costs + Sewer Costs + Water Heating+ Water Heating = = LOT$ of Your MoneyLOT$ of Your Money!!!!

Water Costs Water Costs + Sewer Costs + Sewer Costs + Water Heating+ Water Heating = = LOT$ of Your MoneyLOT$ of Your Money!!!!

62Energy Auditing Techniques for Small and Medium Commercial Facilities

Spray Valve CalculatorSpray Valve CalculatorOnline tool for estimating water $$Online tool for estimating water $$

632009Energy Auditing Techniques for Small and Medium Commercial Facilities63

Play with the water calculator.Play with the water calculator.

What will you find?What will you find?

It’s expensive to waste water!It’s expensive to waste water!(especially hot water)(especially hot water)

64

65

66Energy Auditing Techniques for Small and Medium Commercial Facilities

A Bad SprayerA Bad Sprayer

67

Replace Hand Sink AeratorsReplace Hand Sink Aerators

68Energy Auditing Techniques for Small and Medium Commercial Facilities

Fix all leaks!Fix all leaks!

Even a small drip adds up:

• 50,000 gallons/yr

• $350 for water

• $700 for water heating

69Energy Auditing Techniques for Small and Medium Commercial Facilities

4 Hot Water Heater “Must-Do’s”4 Hot Water Heater “Must-Do’s”

activate

allocateinsulate

regulate

70

Insulate the water lines.Insulate the water lines.Saves about $4 to $5/year/foot*Saves about $4 to $5/year/foot*

*based on horizontal 1.5 inch pipe, 70° F ambient, indoor installation, 80% efficiency

Energy Auditing Techniques for Small and Medium Commercial Facilities

71Energy Auditing Techniques for Small and Medium Commercial Facilities

Regulate the tank temperature Regulate the tank temperature by properly setting the thermostat.by properly setting the thermostat.Example savings: $600 a yearExample savings: $600 a year

72

Allocate the recirc pump operation: Allocate the recirc pump operation: use a timer to turn it off at night.use a timer to turn it off at night.Example savings: $300 a year*Example savings: $300 a year*

*includes $100 in electric pump energy savings

Energy Auditing Techniques for Small and Medium Commercial Facilities

73

Activate the automatic flue-damper Activate the automatic flue-damper control: turn it on!control: turn it on!Example savings: $300 a yearExample savings: $300 a year

Energy Auditing Techniques for Small and Medium Commercial Facilities

742009Energy Auditing Techniques for Small and Medium Commercial Facilities74

75Energy Auditing Techniques for Small and Medium Commercial Facilities

76Energy Auditing Techniques for Small and Medium Commercial Facilities

Resource: On-line Design GuidesResource: On-line Design Guides

77Energy Auditing Techniques for Small and Medium Commercial Facilities

Final Action: Final Action: Re-commission all the Energy Management Systems

78Energy Auditing Techniques for Small and Medium Commercial Facilities

Reinforcement ActivityReinforcement ActivityThe client is going to expand their kitchen and they want to purchase a convection oven, two gas fryers, and a griddle.

1. How do you guide them to efficient equipment?

2. How much money can they get in rebates?

79Energy Auditing Techniques for Small and Medium Commercial Facilities

Reinforcement ActivityReinforcement ActivityThe client is going to expand their kitchen and they want to purchase a convection oven, two gas fryers, and a griddle.

1.How do you guide them to efficient equipment?http://www.fishnick.com/saveenergy/rebates/

2. How much money can they get in rebates?

$500 + $500 + $500 + $125 = $1,625

80Energy Auditing Techniques for Small and Medium Commercial Facilities

Key Points to RememberKey Points to Remember

• Commercial Kitchen Ventilation– optimization and control– demand ventilation (rebates!)

• Cooking Appliances– specifying efficiency– Energy Star and CA Rebates!

• Water and Water Heating– pre-rinse valves, aerators and leaks– hot water heater commissioning

81Energy Auditing Techniques for Small and Medium Commercial Facilities

References and ResourcesReferences and Resources

• www.pge.com/fstc• www.fishnick.com• www.energystar.gov/cfs• www.conserve.restaurant.org

– National Restaurant Association Conserve Program

82Energy Auditing Techniques for Small and Medium Commercial Facilities