Electrical Modalities

Post on 07-May-2015

13052 Views

Category:

Health & Medicine

4 Downloads

Preview:

Click to see full reader

Transcript

ELECTRICAL MODALITIES

Summer Kepley, OTS

Definition

Different forms of energy, dependent on the specific modality, which can penetrate through the skin, the muscles or even the neurological system of the human body, in order to provide relief from swelling and/or pain, muscle stimulation or to promote healing of different body structures, caused from an acute or chronic injury or condition, (Larson, 2007).

Different Levels Cellular Level

Modify skin Increase movementFacilitate wound healingModulate acute pain

Tissue Level Increase tissue

extensibility healingReeducate musclesModulate acute painDecrease muscle disuse

atrophy Increase movement

Segmental Level Increase movementDecrease

edema/inflammation

Facilitate fracture healing

Modulate a pain Systemic Level

Modulate chronic pain

General Purpose

Modulate pain (acute and chronic) Increase tissue extensibility healing Modify skin Decrease edema/inflammation Reeducate muscles Increase movement Decrease muscle disuse atrophy Facilitate fracture and wound healing

When are EM’s used?

“…in preparation for or concurrently with purposeful and occupation-based activities or interventions that ultimately enhance engagement in occupation” (McPhee, 2008).

Who can use EM’s?According to the AOTA, only occupational therapists and occupational therapy assistants with the proper training and skills to integrate the chosen modalities skillfully and safely, and be able to implement them correctly within a proposed occupational therapy program.

General Precautions Never place the

electrodes- On each temple On or near the eyes In the mouth On the front of the neck On the groin On numbed areas of the

skin, or decreased sensation On wounds On or near the uterus of a

woman who is or may be pregnant. (Effects are generally unknown, but may induce labor.)

General Contraindications Pacemaker Cardiac conditions Exposed metal

implants Severe obesity Increased sensitivity

to electrical stimulation

Epilepsy

General Evaluation Guidelines

Clean the skin surface of the body area to be treated. Avoid extremely hairy areas of the body, or where there is a wound. Shaving is not recommended: Micro abbreviation

Inspect the electrode cords and electrode pads for wear. If they are not in good condition, they should be replaced. If they are acceptable, then insert the cord pins into each electrode pad. Never re-use an electrode pad.

Peel away the paper backing of the disposable electrode and place it on the body carefully and securely. Loose electrodes can contribute to burning and irritation of the skin. There are 3 basic pad placements:

○ Monopolar- one electrode running from one channel○ Bipolar- two electrodes running from one channel○ Quadripolar- four electrodes running from two channels

Monopolar and Bipolar should be used when treating a relatively small area and Quadripolar for a larger area. - An example of a larger area is the thigh.

TENS Transcutaneous

Electrical Nerve Stimulation

Transcends an electrical current, to provide constant electrical stimulation to the peripheral nerves, in a specified area of the body, to modulate pain.

Purpose

Decrease pain○ Acute

Persists less than 6 months and is associated with tissue damage, irritation, inflammation or a disease.

Prevent the acute pain reaction cycle from occurring. - Example

○ ChronicStop the pain cycle described above, after it has

already started.

TOOLS For Client Use

○ Portable- can clip on belt or put in a pocket, and control pain as needed or recommended.

For Therapist Use Must have at least 2

electrodes to pass current, but usually comes with 4. ○ Electrodes are thin flexible

pads covered with a gelatin-like substance.

○ The electrodes are connected to a lead wire and a relatively flat, electrical impulse-distribution portion.

○ The connector is attached via the lead wire to a stimulator.

Evaluation Guidelines Pulse Frequency

If you increase the pulse frequency, you are increasing the amount of energy being delivered to the body.

Pulse Amplitude The higher the amplitude,

the more energy released to your body.

Pulse width The longer the pulse, the

more total energy each individual pulse generates.

“Low Fire” Setting○ Endogenous opiates and

endorphins are released and reduce the sensation of pain.

“High Frequency” Setting

○ Gate control theory The electrical current

goes through the peripheral nerves to close the gate in the dorsal horn, and blocks the perception of pain at the level of the spinal cord.

Evaluation Guidelines (cont.)

1. Turn each Intensity Control clockwise and SLOWLY increase the intensity level desired. Wait for tingling sensation

2. When you are finished using the unit, turn down each Intensity Control until an audible click is heard and the pointer is on the word "OFF".

3. Remove the electrode pads from the body.

Precautions Allergic reactions Decreased sensation of

the skin Open wounds Pain is the body’s way of

telling an individual to react to a harmful stimuli or occurrence. Therefore, if the individual is no longer perceiving pain, they may become careless with an injured area and further damage it.

Nerve impingement

Contraindications Epilepsy

Cardiac pacemaker or other metal implants

Extreme obesity

MENS Microcurrent

Electrical Nerve Stimulation

MENS was designed to mimic the electrical, weak currents produced by tissue healing.

Uses micro-amperage current

These devices deliver a level of stimulation below the threshold of peripheral nerve excitation.

General Purpose

Aids in the healing process while relieving pain. Whereas TENS is generally used for

pain relief, MENS works more on a cellular level and aids in the healing process while relieving pain.

TOOLS Portable version Similar to TENS Generally only

has 2 electrodesWave forms- lower

than TENSPulse frequency-

lower than TENSAmplitude- lower

then TENS

Evaluation Guidelines

Either short pulse durations or a constant current is used.

The Amplitude is much lower than the TENS unit, and is set by the therapist.

Guidelines follow the same as the TENS, but is safer then the TENS unit, due to weaker currents passed.

Indications Symptomatic relief and

management of chronic pain

Adjunctive treatment for post-surgical and post-traumatic acute pain

Very low pain tolerance Scarring of the skin Decreased ROM due to

scarring of the skin, or scar tissue close to the skin’s surface

Wound

Precautions Allergic reactions

Pain relief causing exacerbation of the injured site. N. impingement

Contraindications Epilepsy

Cardiac pacemaker or other metal implants

Extreme obesity

IFC Interferential Current

Therapy Crossing two slightly

different medium frequency alternating currents within the tissue, a third frequency current of greater intensity is created in the deeper tissue

4 electrodes total

Allows for centralized concentration of current

Maximized by

electrode placement so that intensity is perceived in area of pain

“Carryover Effect”

Purpose Pain Increase blood

circulation Interferential

current uses very high pulse rate, usually 4001 - 4150 pulses per second.

○ Provides more analgesic, or nerve blocking effect.

TOOLS Because of such frequency, these devices will require a lot of

power, and thus, batteries will not last long. AC Adapters are usually provided with device.

Applies two medium-frequency currents simultaneously

Interference creates a “beat” mode

Sweep frequency

Reduce accomodation

The system can arrange electrodes in either the same plane (for areas such as the back), or in different planes (in areas such as the shoulder).

Evaluation Guidelines Electrode placement

should be in an "X" pattern

Steps to follow: 1. Increase current until

the patient feels a definite prickling, and leave for one minute for it to decrease

2. Increase current again until the patient reports a slight muscular contraction, then decrease until contraction stops

Duration of Treatment

10-15 minutes

treatment at a normal intensity should not be given to one area for longer than 20 min.

if more than one area is to be treated, total time should not exceed 30 min.

Precautions

Allergic reactions Decreased sensation of the skin Open wounds Pain relief causing exacerbation of the

injured site.

Contraindications

Epilepsy Cardiac pacemaker or other metal

implants Extreme obesity

NMES Neuromuscular

Electrical Stimulation A non-invasive

means of muscle rehab after injury, surgery or with disease, that applies customized, low level electrical stimulus to cause a muscle to contract.

The brain tells muscles to contract by sending electrical signals or impulses to them. NMES can act like the

brain by sending similar electrical signals through the skin to the muscles telling them to contract.

The client must have an intact or partially intact peripheral nerve.

Indications CVA, TIA, TBI Muscular Disorders� Neurological �

degenerative diseases/syndromes

Contractures Decreased ROM Edema Decreased blood

flow

“ Functional electrical stimulation (FES) is a type of NMES that is used to enhance the ability to walk in patients with spinal cord injuries or stroke. FES attempts to replace stimuli from destroyed nerve pathways with computer-controlled sequential electrical stimulation of muscles, (NMES PDF, 2006).”

TOOLS A stimulator

transcends an electrical signal that flows through leads to electrodes placed on motor points over a targeted muscle or muscle group.

This causes an electrical reaction in the specified motor nerves and results in muscle contraction.

Stimulus parameters �include: Pulse rate/frequency-

Tension of mm. Pulse amplitude- The

amplitude is increased until strong maximal contraction is obtained, upon tolerance of the client. 

Pulse waveform: Symmetrical- allows both

electrodes to be active, and results in a hard and fast contraction of the muscle or muscle group

Asymmetrical- allows the selective recruitment of smaller muscle fibers

Evaluation Guidelines Electrodes are attached

over a muscle that needs help to contract.

Bipolar placement tends to be used most often in NMES, because for a given intensity of stimulation, more current reaches the muscle to be stimulated.

For optimal bipolar positioning, the clinician should place the muscle at resting length or in a slightly lengthened range, avoiding any close-packed positions of the limb or joint.

A rest cycle that is 5 to 6 times as long as the hold cycle allows the muscle adequate time to recover between contractions and produces same amount tension on each subsequent contraction.

Treatment should be provided daily, or at least every other day, for approximately 15 minutes, total time.

Precautions Muscle fatigue Peripheral n. pathology Patient tolerance Patients with severe

dementia, inability to follow directions and verbalization

Allergic reactions Decreased skin sensation Open wounds The patient must have a

non-neurological reason for disuse atrophy

Contraindications Cardiac pacemakers,

metal implants Pregnancy Neuromuscular or

neurological disorders in which fatigue has a negative impact on the disorder

Severe Obesity Active bleeding

Russian Electrical Stimulation

Similar concept as the NMES, but with medium frequency waveforms.

Russian Stimulation is a specific type of electrical muscle stimulation utilizing a higher carrier frequency of 2500 Hz.

The system is designed to stimulate motor nerves, resulting in muscle contraction.

Originally used for strength training, but currently being used for muscle strengthening, and reduction in muscle spasms and reducing edema.

Indications Scoliosis CVA, TIA TBI Muscular Disorders Neurological

degenerative diseases/syndromes (Ex. Parkinson’s Disease- to increase muscle strength to help reduce fatigue and atrophy).

Edema Decreased blood flow

TOOLS

(May look just like an NMES or other MES systems, and can also be an option on a general MES system)

Similarly, the makeup is the same as the described NMES, but the grading options are much higher.

Evaluation Guidelines

The "10/50/10" Treatment Regimen

“Russian electrical stimulation is applied for a 10-second "on" period followed by a 50-second "off" period, with a recommended treatment time of 10 minutes per stimulation session. The objective is to increase a muscle's ability to generate force”, (Russian, 2009)

Precautions Muscle fatigue Patient tolerance The nerve supply to

the muscle must be intact

Contraindications Cardiac pacemakers Previous casting or splinting of

the limb Contracture from a burn Hip replacement surgery Patients with severe dementia,

inability to follow directions and verbalization

DO NOT use on smaller muscles or muscle groups, such as: Muscles of the throat and face Mm. of the hands and feet

Neuromuscular or neurological disorders in which fatigue has a negative impact on the disorder

Iontophoresis A non-invasive, pain free

method of delivering medication into the body using a low electrical current

Iontophoresis is able to �transcend drug ions through the skin and underlying tissue through a low-level electrical current, (Empi, 2010).

General Purpose Provides option for

patients reluctant or unable to receive injections

Decreases risk or infection

Medication is delivered directly to treatment site

Decreases tissue damage Delivers medication much

quicker, and effects can be felt within minutes, (Empi, 2010).

Can be, and is often used in conjunction with other modalities.

Often used before therapy to reduce inflammation and pain.

TOOLS The majority of units

consist of a compact phoresor that operates with a 9-volt battery and two wire leads, each connected to an electrode. One electrode is the drug-

delivery electrode, the other is used as a dispersive electrode charged opposite to the first one.

When the electrodes contain solutions of ions, negatively charged anions are repelled from the cathode into the body

Evaluation Guidelines The inflammation must be

near the body surface (Ex. a superficial muscle or tendon rather than a deep muscle tendon bursa).

The medication must carry a charge to work with the iontophoresis.

Transient erythmia often occurs, but is normal and the patient should be informed prior to treatment.

Be sure to start with a mild sensation, so that the client feels only a tingling sensation and is not uncomfortable.

Place the negative end of the electric charge on a part of the client’s body, away from the intended area.

Apply the medication on the client’s affected area.

Put another pad on it for the positive electrical charge.

Turn on the electrical source and the charges of the medicine and electricity will push the medicine into the intended area.

Precautions Burning of the skin! Electrical discharges

(sparks) may occur Do not use in the

presence of flammable anesthetics

Do not apply over an area where the hair has been shaved in the past 24 hours.

Known skin allergies

Contraindications

Allergic reaction to medication Higher fat content Cardiac pacemakers Known sensitivity to ionic solutions Damaged skin, wounds or recent scar

tissue

American Occupational Therapy Association. (2004). Roles and responsibilities of the occupational therapist and occupational therapy assistant during the delivery of occupational therapy services. American Journal of Occupational Therapy, 58, 663-667. Bracciano, A.G. (2008). Physical agent modalities: Theory and application for the occupational therapist (2nd ed.). Thorofare, NJ: Slack. eMedicine, Clinical Knowledge Base. (2007). Transcutaneous electrical nerve stimulation. Retrieved January 16, 2010 from http://www.emedicine.com/pmr/topic206.htm#section~introduction Empi: Health care professionals. (2009). DJO, Inc. Retrieved January 15, 2010 from http://www.empi.com/healthcare_professionals/detail.aspx?id=106 Iontophoresis drug delivery electrode insert. (2009). Pain Management. Life Tech, Inc. Retrieved January 17, 2010 from http://www.life-tech.com/pm/meditrodeindications.shtml Larson, J. (2007). Electrical stimulation therapy. Wild Irish Medical Education, Inc. Retrieved January, 15 2010 from http://www.nursingceu.com/courses/211/index_nceu.html McPhee, S.D. (2008). “Physical Agent Modalities: A Position Paper”. American Journal of Occupational Therapy, The. FindArticles.com. Retrieved January 12, 2010 from http://findarticles.com/p/articles/mi_hb5914/is_n32312314/ Modalities. (2009). Occupational Therapy: University Hospitals. Retrieved January 13, 2010 from http://www.uhhospitals.org/tabid/3728/Default.aspx “Neuromuscular electrical stimulation. Fallon Community Health Plan. (2006). Retrieved January 15, 2010 from http://www.fchp.org/NR/rdonlyres/50B823A6-3A65-44C3-A7AE-6C31A7B11A3E/0/NeuromuscularStimulation.pdf Pendleton, H.M. & Krohn, W.S. (2006). Pedretti’s occupational therapy: Practice skills for physical dysfunction (6th ed.). St. Louis, MI: Mosby, Inc. Russian electrical stimulation. (2009). Equinew, LLC. Retrieved January 18, 2010 from http://www.equinew.com/russian.htm 

top related