Installation and servicing instructions
M03
633
LF2
-01-
0213
2
MagnaClean® DualXP's in-line design and 360° rotational connectors provide multiple installation options for both vertical and horizontal pipework. This ensures greater flexibility within tight working environments.
Multiple installation options
FOR BEST RESULTS Install and service with MC1+ Protector, the advanced system inhibitor from ADEY, Europe’s largest water treatment manufacturer for central heating systems.
Dual
MagnaClean DualXP delivers exceptional protection against the damaging effects of black iron oxide sludge and non-magnetic debris. The unique design makes it a leader in its class giving professional installers a dedicated filter bridging the gap between ADEY’s extensive domestic filter range, which is installed in more than three million UK homes, and the company’s heavy duty commercial filters.
IMPORTANT Follow the Standard Electrical Best Practice guidelines when installing a MagnaClean filter. A copy of these guidelines can be found at: www.hse.gov.uk/electricity The inlet and outlet on MagnaClean DualXP are reversible and there is no flow restriction. Following installation, don’t forget to complete the warranty card. Alternatively, complete the registration online at adey.com/warranty
MagnaClean DualXP
Maximum working pressure: 6 bar
Maximum working temperature: 95°C
Flow rate: Recommended rate for optimum capture up to 100 litres per minute
Volume: 2.43 litres (when telescopic connectors are retracted)
Exceptional protection for 1½” or 1¼” light commercial heating systems
MagnaClean® DualXP has been developed by the industry leading and multi-award winning company that pioneered magnetic filtration within this sector. ADEY’s filters are already protecting more than three million heating systems in the UK.
MagnaClean DualXP can be installed anywhere on the main circuit. However, to achieve the best level of protection for the boiler, it is recommended to install the filter after the last radiator on the system and before the boiler. It is important to install valves either side of the MagnaClean DualXP. Isolation valves and fittings for copper pipework not included.
Installation
The following instructions are designed to support engineers in the safe and effective installation and servicing of MagnaClean DualXP and should be followed at all times.
Any queries should be directed to your supervisor or ADEY direct on 01242 546717.
MagnaClean DualXP is suitable for both domestic heating systems shown here as well as larger light commercial heating systems.
Open vented system Combi/Sealed system
N.B. We firmly recommend MagnaClean DualXP is installed and serviced by a qualified heating engineer. Knurled nuts should behand-tightened only.
Your system is protected by
Annual service requiredadey.com
Servicing
D
DETAIL DSCALE 1 : 2
Dual
In both diagrams, position A is best practice, while B is suitable.
C
2
A
A
375
PIPE
CUT
LENG
TH
118
FIXE
D PO
RT C
ENTR
ES
SECTION A-ASCALE 1 : 2
1. AFTER CUTTING PIPE AND CUTTING THREAD. FIT BOTTOM ELBOW ASSEMBLY.
2. BOTTOM ELBOW TO BE IN FULLY RETRACTED POSITION, AFTER LOCKING BLACK NUT AGAINST RED BUSH. TURN RED BUSH CLOCKWISE UNTIL COMPLETE ASSEMBLY HAS BECOME RIGID (CONNECTION TO FILTER, CANNOT BE TURNED).
3. FIT TOP ELBOW, DO NOT LOCK - MOVE CONNECTION AND PUSH FILTER ON TO SPIGOTS - DO NOT LOCK FILTER TO CONNECTORS.
4. LOCK CONNECTOR - BLACK NUT AGAINST RED NUT ONLY.
5. LOCK CONNECTORS TO FILTER.
FITTING DUAL XP TO 1-1/2" PIPEWORK
3
Hold
A
A
375
PIPE
CUT
LENG
TH
118
FIXE
D PO
RT C
ENTR
ES
SECTION A-ASCALE 1 : 2
1. AFTER CUTTING PIPE AND CUTTING THREAD. FIT BOTTOM ELBOW ASSEMBLY.
2. BOTTOM ELBOW TO BE IN FULLY RETRACTED POSITION, AFTER LOCKING BLACK NUT AGAINST RED BUSH. TURN RED BUSH CLOCKWISE UNTIL COMPLETE ASSEMBLY HAS BECOME RIGID (CONNECTION TO FILTER, CANNOT BE TURNED).
3. FIT TOP ELBOW, DO NOT LOCK - MOVE CONNECTION AND PUSH FILTER ON TO SPIGOTS - DO NOT LOCK FILTER TO CONNECTORS.
4. LOCK CONNECTOR - BLACK NUT AGAINST RED NUT ONLY.
5. LOCK CONNECTORS TO FILTER.
FITTING DUAL XP TO 1-1/2" PIPEWORK
4 6
Hold
75
D
DETAIL DSCALE 1 : 2
1 2 3 4 5 6 7
D
DETAIL DSCALE 1 : 2
1
1
1
1
1
1
2
2
1
2
3
Open
1
Close
1
2 Open
3Close
Remove sleeve
1
2
3
Clean
Clean
4
Clean
1
2
1
1
400m
m
1
2
1¼“1
375m
m
1½“1
ORRü ü
ü
D
DETAIL DSCALE 1 : 2
D
DETAIL DSCALE 1 : 2
D
DETAIL DSCALE 1 : 2
2
3
Open
Close
û
û25mm
25mm
31¼’’BSPT
2
1¼’’BSPT
25mm
25mm
1½’’BSPT
1½’’BSPT
1
2
2
1
û
ü
A
A
375
PIPE
CUT
LENG
TH
118
FIXE
D PO
RT C
ENTR
ES
SECTION A-ASCALE 1 : 2
1. AFTER CUTTING PIPE AND CUTTING THREAD. FIT BOTTOM ELBOW ASSEMBLY.
2. BOTTOM ELBOW TO BE IN FULLY RETRACTED POSITION, AFTER LOCKING BLACK NUT AGAINST RED BUSH. TURN RED BUSH CLOCKWISE UNTIL COMPLETE ASSEMBLY HAS BECOME RIGID (CONNECTION TO FILTER, CANNOT BE TURNED).
3. FIT TOP ELBOW, DO NOT LOCK - MOVE CONNECTION AND PUSH FILTER ON TO SPIGOTS - DO NOT LOCK FILTER TO CONNECTORS.
4. LOCK CONNECTOR - BLACK NUT AGAINST RED NUT ONLY.
5. LOCK CONNECTORS TO FILTER.
FITTING DUAL XP TO 1-1/2" PIPEWORK