Cisco MDS 9000 and EMC XtremIO Flash Arrays
Mark Allen September 2015
Building Best-of-Breed Storage Solutions
2 © 2015 Cisco and/or its affiliates. All rights reserved.
Evolution: A process of continuous change from a lower, simpler, or worse to a higher, more complex, or better state*
• * Merriam-Webster definition
3 © 2015 Cisco and/or its affiliates. All rights reserved.
Spinning disk has been the standard for Data Center storage for decades
• Performance and speed have increased while cost has decreased
The introduction of Flash storage is revolutionizing Data Center storage • Dramatic increases in performance over spinning disk • Reduced cost of ownership makes flash a more competitive storage choice • Increased functionality to meet Enterprise needs
Evolution of Storage
4 © 2015 Cisco and/or its affiliates. All rights reserved.
Why Flash Storage?
• Application Responsiveness
• Increased Virtualization
• Reducing Performance Gap
• Flash Storage increases performance for random and sequential data access
• Data Deduplication uses storage more efficiently
• Flash Storage provides consistent performance as well as benefits in power and space
5 © 2015 Cisco and/or its affiliates. All rights reserved.
• Scale Out Architectures • High Availability and Reliability • Multi-tenancy support • Simplicity of Management
Cisco Storage Networking and EMC XtremIO Flash Arrays Synergy of Solutions
6 © 2015 Cisco and/or its affiliates. All rights reserved.
5-120TB Based on 10 & 20 TB X-Bricks
150K MIXED IOPS 250K READ IOPS <1MS LATENCY
900K MIXED IOPS 1.5M READ IOPS <1MS LATENCY
• Designed for Scalable growth for new or existing deployments
• Linear performance growth
• Consistent latency
XtremIO Scale Out Architecture
7 © 2015 Cisco and/or its affiliates. All rights reserved.
Non-oversubscribed Line Rate 16 Gbps Ports
MDS 9148S
MDS 9396S
MDS 9706 MDS 9710
12 - 48
48 - 384 • Scalable Solutions for different sized deployments
• Line rate performance with no over-subscription
• Consistent, Predictable performance
Cisco MDS Scale Out Architecture
8 © 2015 Cisco and/or its affiliates. All rights reserved.
Crossbar Switch with Central Arbitration
Ingress
Egress
Crossbar
Control and Scheduling
Cisco MDS Architecture
• Crossbar establishes a temporary connection between input and output port for duration of the frame exchange
• Frames are not transmitted unless there is an available path
• Scheduler uses arbiter grants to provide traffic fairness and QoS
• Virtual Output Queues used to eliminate HOL blocking
9 © 2015 Cisco and/or its affiliates. All rights reserved.
Fabric
Crossbar Switch Fabric
Fabric
Crossbar Switch Fabric
Fabric
Crossbar Switch Fabric
• Frames always follow same logic – ingress to egress (consistent switching latency)
• Newer generation line cards use fewer components compared to first generation line cards, however, the frame forwarding logic is the same
Sup Central Arbiter
Egress Access Control and QoS Forwarding and Load balancing
Inter VSAN Routing
Sup Central Arbiter
Cisco MDS Frame Flow
MAC Port Type / Modes: • F_Port • Loop port (FL_Port) • ISL (E_Port) • EISL (TE_Port) • SPAN Port (SD_Port)
PHY / MAC Forwarding
Queuing
PHY Optical to Electrical interface: • SFP+ (2/4/8/10/16 Gbps)
Error Checking Timestamp
VSAN Header
Linecard
Access Control Forwarding and Load balancing
Inter VSAN Routing Interface Statistics
Buffering and Virtual Output Queues QoS
Arbitration Requests
Redundant Arbiters
Transmit, loopback or Expire frame Remove VSAN header (end device) or prepend
EISL header (EISL to Cisco switch) Redundant crossbar fabrics
10 © 2015 Cisco and/or its affiliates. All rights reserved.
FC, FCoE Modules
Cisco MDS 9700 - Designed for Scale 1
2
3
4
5
6
Host Ports
Number of Fabric Cards FC Bandwidth per Slot FCoE Bandwidth per Slot
1 256 Gbps 220 Gbps
2 512 Gbps 440 Gbps
3 768 Gbps 660 Gbps
4 1024 Gbps 880 Gbps
5 1280 Gbps 1100 Gbps
6 1536 Gbps 1320 Gbps
11 © 2015 Cisco and/or its affiliates. All rights reserved.
• Disk Array Enclosure (DAE): • 13 or 25 eMLC SSDs • Two redundant power supply units (PSUs) • Two redundant SAS interconnect modules
• One Battery Backup Unit
• Two 1U Storage Controllers: • Two redundant Power Supply Units
(PSUs) • Two 8Gb/s Fibre Channel (FC) ports • Two 10GbE iSCSI ports • Two 40Gb/s InfiniBand ports
EMC XtremIO X-Brick High Availability
Disk Array Enclosure (DAE)
Storage Controller
Storage Controller
Battery Backup Unit
12 © 2015 Cisco and/or its affiliates. All rights reserved.
• Grid Redundant Power Supplies • Two (MDS 9148S, MDS 9396S) • Four (MDS 9706) • Eight (MDS 9710)
• Redundant Fan Modules • Two (MDS 9148S, MDS 9396S) • Three multi-fan (MDS 9706, MDS 9710)
• Redundant Supervisors (MDS 9706, MDS 9710)
Cisco MDS High Availability MDS 9148S
MDS 9396S
MDS 9706
MDS 9710
13 © 2015 Cisco and/or its affiliates. All rights reserved.
High Availability extended beyond the physical switch
• MDS Port Channels reduce failure domains by allowing ISLs to be spread over:
• Different Line Cards • Different ASICs • Different Port-groups
• Scalable - Up to 16 ISL per Port Channel, up to 16 Port Channels between switches
• Flexible – add ports and/or Port Channels as needed
MDS PortChannels
Cisco MDS 9000 Port Channels – Fabric High Availability
14 © 2015 Cisco and/or its affiliates. All rights reserved.
• Low data protection capacity overhead of 8%
• Automatic rebuild in case of drive failure
• Incoming Data Protection Robustness
• Administrative ease through fail-in-place support
EMC XtremIO Data Protection (XDP)
Capacity Utilization
Superior Protection
High Performance
15 © 2015 Cisco and/or its affiliates. All rights reserved.
Cisco MDS 9000 Fabric Protection CRC Detection and 16 Gbps FC Forward Error Correction (FEC)
Ingress CRC
checking
Internal CRC
checking
Forward Error
Correction
Drop frame
Drop frame
• Faulty equipment, loose SFPs, dirty or damaged cables, can result in packets getting corrupted
• CRC Checking drops corrupted frames from end devices or internally corrupted frames
• FEC corrects frames corrupted in-flight to preserve frames
16 © 2015 Cisco and/or its affiliates. All rights reserved.
Snapshots can be used to allow simultaneous Development and Operations (DevOps)
• Leverages content-aware capabilities of the system (Inline Data Reduction)
• Unique metadata tree structure directs I/O to the right timestamp of the data
• Metadata shared between all snapshot blocks that have not been changed from the snapshot's original ancestor
EMC XtremIO Multi-tenancy
17 © 2015 Cisco and/or its affiliates. All rights reserved.
Option to use QoS within SAN for multi-tenancy • User defined QoS values • Allows different application to have different priority
(ie Development/Test vs. Production)
Cisco MDS QoS - Multi-tenancy within the SAN
B A
C C C C B A C C C C C A C B
ARB
Input port
Output Port
Output Port
Output Port
DWRR Weight Priority Absolute
Queue 2 60 Queue 3 10 Queue 4 30
Application “A”
Application “B”
Application “C”
DWRR Weight Priority Absolute
Queue 2 70 Queue 3 20 Queue 4 10
DWRR Weight Priority Absolute
Queue 2 55 Queue 3 30 Queue 4 15
18 © 2015 Cisco and/or its affiliates. All rights reserved.
Virtualization for SANs • SAN islands virtualized onto common physical SAN • Ports allocated within a physical fabric to create
virtual fabrics • Fabric disruption is limited to VSAN
VSANs provide • Dynamic provisioning and resizing • Improved port utilization • Non-disruptive reassignment • Shared ISL bandwidth
Cisco MDS VSANs for Virtualization
19 © 2015 Cisco and/or its affiliates. All rights reserved.
VSAN 30 VSAN 31
VSAN 20 VSAN 21
VSAN 10 VSAN 11
Using VSANs to Provide Multi-tenancy
Application “A”
Application “B”
Application “C”
20 © 2015 Cisco and/or its affiliates. All rights reserved.
XtremIO Provisioning removes steps from the typical process
• Minimum planning No RAID configuration Minimal sizing effort for cloning/snapshots
• No tiering Single tier, all-flash array
• No performance tuning Independent of I/O access pattern, cache hit rates, tiering decisions, etc.
EMC XtremIO Ease of Management
Step 1: Create
Volumes
Step 2: Map
Volumes
Step 3: Create Initator Groups
21 © 2015 Cisco and/or its affiliates. All rights reserved.
Create fewer zones at an application level or physical/cluster level
Cisco MDS 9000 Ease of Management - Smart Zoning
Smart Zoning: • Simplicity of multi-member zones • Internal efficiency of one-to-one
12 x I 2 x T
I
I
I I
I
I
I
I
I
T
T
I I
I Multi-member zones: • What you want • What you get
22 © 2015 Cisco and/or its affiliates. All rights reserved.
Smart Zoning: Configuration Example Smart Zoning: Requires only 1 zone with 12 hosts and 2 X-Brick pwwns. Zoneset name Smart-VDI vsan 200
zone name x-brick1 vsan 200 pwwn 15:10:10:10:10:10:10:01 initiator pwwn 15:10:10:10:10:10:10:02 initiator pwwn 15:10:10:10:10:10:10:03 initiator pwwn 15:10:10:10:10:10:10:04 initiator . . pwwn 15:10:10:10:10:10:10:12 initiator pwwn 25:20:20:20:20:20:20:01 target pwwn 25:20:20:20:20:20:20:02 target
Adding another VDI cluster would require adding the new X-Brick ports and new hosts to the existing zone or adding the 2 new X-Brick pwwns to the first zone and creating one additional zone with all 4 X-Brick ports together with the new hosts..
Traditional Zoning: (Requires 24 two-member zones) Zoneset name VDI vsan 100
zone name host1-x-brick1a vsan 100 pwwn 10:10:10:10:10:10:10:01 pwwn 20:20:20:20:20:20:20:01
zone name host1-x-brick1b vsan 100 pwwn 10:10:10:10:10:10:10:01 pwwn 20:20:20:20:20:20:20:02
zone name host2-x-brick1a vsan 100 pwwn 10:10:10:10:10:10:10:02 pwwn 20:20:20:20:20:20:20:01
zone name host2-x-brick1b vsan 100 pwwn 10:10:10:10:10:10:10:02 pwwn 20:20:20:20:20:20:20:02
. . zone name host12-x-brick1a vsan 100
pwwn 10:10:10:10:10:10:10:12 pwwn 20:20:20:20:20:20:20:01
zone name host12-x-brick1b vsan 100 pwwn 10:10:10:10:10:10:10:12 pwwn 20:20:20:20:20:20:20:02
Adding another VDI cluster would require an additional 72 zones to be configured per fabric.
23 © 2015 Cisco and/or its affiliates. All rights reserved.
EMC XtremIO Flash Arrays and Cisco MDS Switches and Directors • Industry leading technologies and features
• Combined provides a greater solution (1 + 1 = 3)
• Fully Qualified by both EMC and Cisco
Summary