Transcript
Ref. No.: GC/SD/BR-728/12 Revision No.0
PROPOSED BUILDING No. 57 PROJECT IN KFUPM
Kingdom of Saudi Arabia
REPORT
FOR
RE-SCANNING SURVEY OF TREATED CAVITIES UNDER
BUILDING No. 57 (Ref No.: GC/SD/BR-728/12)
PREPARED FOR
ISAM KABBANI & PARTNERS
PREPARED BY
GULF CONSULT SURVEY DIVISION
JUNE 2012
0 Issued for Approval BRR GH SGM 19-06-2012
Rev. No. Description Prepared by Checked by Approved by Issue Date
مكتب الخليج لالستشارات الهندسية GULF CONSULT
Job No. GC/4322JO/11761-A2/11
Ref. No.: GC/SD/BR-728/12 Revision No.0
PROPOSED BUILDING No. 57
Project in KFUPM Report for Re-scanning Survey of Treated
Cavities Under Building No. 57 Kingdom of Saudi Arabia
TABLE OF CONTENTS
Page
TRANSMITTAL LETTER ii
I. INTRODUCTION 1
II. PURPOSE 1
III. METHODOLOGY 2
IV. GPR RE SCANNING PROCEDURE 7
V. STUDY AND CONCLUSION 10
VI. REFERENCES 10
VII. GPR PROFILE IMAGES 11
Page i
علي خضير الحربي/ م :لصاحبه License No. 408 ٤٠٨رخصه رقم
Geotechnical Division: E-Mail: geotech@gulfconsult.com Website: www.gulfconsult.com Head Office: P.O. Box 684-Al Khobar 31952 Tel: +966 3 8944468 / 8955036 / 8949872 Fax: +966 3 8949015 Jubail Support Industry: P.O.Box 10113 – Jubail 31961 Tel: +966 3 3410018 Fax: +966 3 3410017
ستشارات الهندسية إلمكتب الخليج لGULF CONSULT
ISAM KABBANI & PARTNERS FOR CONSTRUCTION & Date: 19th June 2012 MAINTENANCE CO. LTD. Ref. No.: GCL/SD/BR-728/12 P. O. Box 6897, Dammam 31452 Kingdom of Saudi Arabia Tel.: (03) 857 0034 x 3477 & Fax (03) 859 0289 Attention: ENG. MOHAMMED RIYADH Project Manager Subject: REPORT FOR RE-SCANNING SURVEY OF TREATED CAVITIES FOR THE
PROPOSED BUILDING No. 57 PROJECT IN KFUPM, KINGDOM OF SAUDI ARABIA.
Dear Sir:
We are pleased to submit herewith our report on GPR survey of treated cavities for the proposed Building no. 57 project in KFUPM which was re-scanned and executed on 6th of June 2012 in Dhahran, Kingdom of Saudi Arabia.
This report presents the field data survey with the methodology, collection of data, processing and interpretation.
Should there be any questions regarding the contents on this report, please call us at your most convenient time.
Very truly yours, For GULF CONSULT Prepared by: SAID G. MIKHAEL BERN R. RAMOS General Manager Project Manager Survey Division
Page ii
مكتب الخليج لالستشارات الهندسية GULF CONSULT
Job No. GC/5163JO/12600-A1/12
Ref. No.: GC/SD/BR-728/12 Page 1 Revision No.0
I. INTRODUCTION GULF CONSULT was retained by ISAM KABBANI & PARTNERS (IKP) to perform and re-
scan the treated anomalies/weak spots/cavities for the proposed Classroom Building no. 57
project in King Fahd University of Petroleum & Minerals (KFUPM), Kingdom of Saudi Arabia.
It is situated at 6Km North West of City Center of Al-Khobar. Its geographic location is 26° 18'
51.02" North Latitude and 50° 08' 57.51" East Longitude. See Figure 1.
Figure 1: shows the project site.
II. PURPOSE The main objective of the re-scanning survey is to check the subsoil weak spots/fractures/cavities
that were treated to 12 locations of the same depth that were previously been detected and
analyzed. At the end of the survey, GULF CONSULT shall provide IKP the survey report showing
images of these treated cavities in comparison with the previous data submitted.
THIS SITE
مكتب الخليج لالستشارات الهندسية GULF CONSULT
Job No. GC/5163JO/12600-A1/12
Ref. No.: GC/SD/BR-728/12 Page 2 Revision No.0
III. METHODOLOGY The Scope of Work of this study is to re scan the proposed construction of building no. 57 project
in KFUPM, KSA. The scope of work performed by us consisted of the following:
1. Set the limit of underground cavity detection survey.
2. Perform Line Scan on Points #1, #2, #3, #5, #7, #8, #9, #11 & #12 where small size suspected cavities were found.
3. Perform 3d Scan on Points #4, #6 & #10 where high anomalies were marked on these areas.
4. A maximum depth of 15m along parallel lines at 1m equal interval using 100 MHz & 400 MHz antennas Ground Penetrating Radar (GPR) to determine these anomalies are free from unwanted cavities and voids.
5. Field sketching will be prepared in conjunction with underground detection survey as reference for data acquisition and processing.
6. Upon completion of field works, the survey area shall be reinstated to its pre-survey condition and;
7. Prepare engineering report to include the methodology, collection of data, processing, interpretation, and conclusion.
مكتب الخليج لالستشارات الهندسية GULF CONSULT
Job No. GC/5163JO/12600-A1/12
Ref. No.: GC/SD/BR-728/12 Page Revision No.0 7
IV. GPR RE-SCANNING PROCEDURE GPR re-scanning was carried out in a cross-section direction for the detected low suspected
cavities. Shown in Figure 2 marked the direction for the low spot anomalies treated prior to re-
scanning.
N
W EEN
NW
SESW
S
Figure 2: Re-scanning Direction of Low Treated Anomalies
مكتب الخليج لالستشارات الهندسية GULF CONSULT
Job No. GC/5163JO/12600-A1/12
Ref. No.: GC/SD/BR-728/12 Page Revision No.0 8
Figures 3 & 4 show how the re-scanning direction went through for the marked highly treated
cavities.
N
W EEN
NW
SESW
S
Figure 3: Re-scanning Direction of High Treated Anomalies in X-Direction
مكتب الخليج لالستشارات الهندسية GULF CONSULT
Job No. GC/5163JO/12600-A1/12
Ref. No.: GC/SD/BR-728/12 Page Revision No.0 9
N
W EEN
NW
SESW
S
Figure 4: Re-scanning Direction of High Treated Anomalies in Y-Direction
مكتب الخليج لالستشارات الهندسية GULF CONSULT
Job No. GC/5163JO/12600-A1/12
Ref. No.: GC/SD/BR-728/12 Page Revision No.0 10
V. STUDY AND CONCLUSION
This study was executed on the request of IKP project team to be able to review the present
condition of the subsoil upon completion of the treatment of the weak spots, fractures & cavities.
GULF CONSULT was retained by IKP to re-scan the foundation area with series of parallel lines at
1m interval in one direction which prior to re-scanning, the foundation area was treated and filled
with grout for stability of the subsoil.
As a result, GULF CONSULT executes the non-destructive Ground Penetrating Radar (GPR)
survey to locate those high greater response and larger pattern and shows images of the treated
weak zones.
Figure 20, 21, 22, … up to figure 42 exhibit the “Before and After treatment of the weak zone” on
page 12 to 23.
Obviously, the rough images before the treatment show greater magnitude compare to the present
subsoil condition after the treatment process where the present image is smooth and dimmer than
previous image. Therefore, we conclude that the weak zone has been properly treated accordingly.
VI. REFERENCES
• Standard Guide for Using Surface Ground Penetrating Radar Method for Subsurface Investigation, ASTM D6432-99 (2005)
• Geophysical Survey Systems, Inc., User’s Manual for SIR system – 3000.
• Geotechnical Investigation for the Proposed Academic Building no. 57 in KFUPM, KSA with reference Job no. GC/4844JO/12281/11 dated 06th December 2011.
• GPR Report for the Proposed Extension of Engineering College Building no. 75 in KFUPM, KSA with reference Job no.: GC/5163JO/12600/12 dated 09th April 2012.
• GPR Report for the Proposed Academic Building no. 57 in KFUPM, KSA with reference Job no. GCL/SD/BR-723/12 dated 21st May 2012.
مكتب الخليج لالستشارات الهندسية GULF CONSULT
Job No. GC/5163JO/12600-A1/12
Ref. No.: GC/SD/BR-728/12 Page Revision No.0 11
PROPOSED BUILDING No. 57 Project in KFUPM
Survey Report for Underground Cavity Investigation By Non-Destructive Method
Kingdom of Saudi Arabia
GPR PROFILE IMAGES
مكتب الخليج لالستشارات الهندسية GULF CONSULT
Job No. GC/5163JO/12600-A1/12
Ref. No.: GC/SD/BR-728/12 Page Revision No.0 12
Figure 19: presents the GPR profile section of Line 1 (Before Cavity Treatment)
Figure 20: presents the GPR profile section of Line 1 (After Treatment)
1
مكتب الخليج لالستشارات الهندسية GULF CONSULT
Job No. GC/5163JO/12600-A1/12
Ref. No.: GC/SD/BR-728/12 Page Revision No.0 13
Figure 21: presents the GPR profile section of Line 2 (Before Cavity Treatment)
Figure 22: presents the GPR profile section of Line 2 (After Treatment)
2
مكتب الخليج لالستشارات الهندسية GULF CONSULT
Job No. GC/5163JO/12600-A1/12
Ref. No.: GC/SD/BR-728/12 Page Revision No.0 14
Figure 23: presents the GPR profile section of Line 3 (Before Cavity Treatment)
Figure 24: presents the GPR profile section of Line 3 (After Treatment)
3
مكتب الخليج لالستشارات الهندسية GULF CONSULT
Job No. GC/5163JO/12600-A1/12
Ref. No.: GC/SD/BR-728/12 Page Revision No.0 15
Figure 25: presents the GPR profile section of Line 4 (Before Cavity Treatment)
Figure 26: presents the GPR profile section of Line 4 (After Treatment)
4
مكتب الخليج لالستشارات الهندسية GULF CONSULT
Job No. GC/5163JO/12600-A1/12
Ref. No.: GC/SD/BR-728/12 Page Revision No.0 16
Figure 27: presents the GPR profile section of Line 5 (Before Cavity Treatment)
Figure 28: presents the GPR profile section of Line 5 (After Treatment)
5
مكتب الخليج لالستشارات الهندسية GULF CONSULT
Job No. GC/5163JO/12600-A1/12
Ref. No.: GC/SD/BR-728/12 Page Revision No.0 17
Figure 29: presents the GPR profile section of Line 6 (Before Cavity Treatment)
Figure 30: presents the GPR profile section of Line 6 (After Treatment)
6
مكتب الخليج لالستشارات الهندسية GULF CONSULT
Job No. GC/5163JO/12600-A1/12
Ref. No.: GC/SD/BR-728/12 Page Revision No.0 18
Figure 31: presents the GPR profile section of Line 7 (Before Cavity Treatment)
Figure 32: presents the GPR profile section of Line 7 (After Treatment)
7
مكتب الخليج لالستشارات الهندسية GULF CONSULT
Job No. GC/5163JO/12600-A1/12
Ref. No.: GC/SD/BR-728/12 Page Revision No.0 19
Figure 33: presents the GPR profile section of Line 8 (Before Cavity Treatment)
Figure 34: presents the GPR profile section of Line 8 (After Treatment)
8
مكتب الخليج لالستشارات الهندسية GULF CONSULT
Job No. GC/5163JO/12600-A1/12
Ref. No.: GC/SD/BR-728/12 Page Revision No.0 20
Figure 35: presents the GPR profile section of Line 9 (Before Cavity Treatment)
Figure 36: presents the GPR profile section of Line 9 (After Treatment)
9
مكتب الخليج لالستشارات الهندسية GULF CONSULT
Job No. GC/5163JO/12600-A1/12
Ref. No.: GC/SD/BR-728/12 Page Revision No.0 21
Figure 37: presents the GPR profile section of Line 10 (Before Cavity Treatment)
Figure 38: presents the GPR profile section of Line 10 (After Treatment)
10
مكتب الخليج لالستشارات الهندسية GULF CONSULT
Job No. GC/5163JO/12600-A1/12
Ref. No.: GC/SD/BR-728/12 Page Revision No.0 22
Figure 39: presents the GPR profile section of Line 11 (Before Cavity Treatment)
Figure 40: presents the GPR profile section of Line 11 (After Treatment)
11
مكتب الخليج لالستشارات الهندسية GULF CONSULT
Job No. GC/5163JO/12600-A1/12
Ref. No.: GC/SD/BR-728/12 Page Revision No.0 23
Figure 41: presents the GPR profile section of Line 12 (Before Cavity Treatment)
Figure 42: presents the GPR profile section of Line 12 (After Treatment)
12
top related