California Title 24 2013 Lighting and Lighting Controls Onlyfiles.ctctcdn.com/c817d9ef201/dcfc1276-bb07-44bb... · • Example: When a dining room switched from the kitchen, code
Post on 11-Aug-2020
7 Views
Preview:
Transcript
© 2014 Eaton. All rights reserved.
Date: July 29, 2014
California Title 24 2013 Lighting and Lighting Controls Only Scope: Title 24 2013 – Residential Compliance
2 © 2014 Eaton. All rights reserved.
Outline
• Scope of “Residential Compliance” • Key definitions • When Title 24 compliance is required • Spaces – Structure for code • Solutions for Title 24 2013 compliance
3 © 2014 Eaton. All rights reserved.
Scope of “Residential Compliance”
Title 24 Occupancy Types include R-1, R-2, R-3, and R-4. CEC is clarifying the full scope that touches upon the living spaces, “dwellings”, of these types.
With additional requirements
Single Family Home Multi-Family Home High-Rise Home
Dormitory Senior Living Quarters Hotel / Motel / Guest Rooms
4 © 2014 Eaton. All rights reserved.
Key definitions Certified to Title 20 Appliance Database (T20)
• Repository of products manufactures report meet the requirements of the appliance codes
• For residential, includes self-contained lighting controls and LED luminaires
Occupancy Group • Classification of that defines the compliance types of a
space • Residential Compliance only applies to a portion of
Group R and Group U (Group U, when located on Single Family lot)
Location of circuit • Critical to know how the lighting products are switched • Control switch/circuit in a space will determine the
compliance requirements • Example: When a dining room switched from the
kitchen, code requires the dining room lighting meet the kitchen code requirements.
High Efficacy • Used in Resident Compliance ONLY • Lighting products reported by manufacturers
meeting the code requirements • Requirements and reporting vary by
technology type (i.e.: LED luminaires T20, CFL luminaires using T20 CFL ballasts)
Low Efficacy • Used in Residential Compliance ONLY • Lighting products that are NOT reported by
manufactures meeting high efficacy code requirements
Self-contained Lighting Controls • Control module that requires no additional
component to be fully functional • Must be certified to Title 20 Appliance
Database to be sold in California for California use
5 © 2014 Eaton. All rights reserved.
New Construction
Additions
Alterations
Modification- in-Place
Repair
When Title 24 Code compliance is required
Single Family All Other Residential
LED Module Note
Not discussed
Not discussed
New Construction
Additions
Alterations
Modification- in-Place
Repair
≥10% Luminaires
≥40 Luminaires, 1:1 Replace
Not discussed
6 © 2014 Eaton. All rights reserved.
Spaces – Structure of code Kitchens
Other Rooms Outdoor – Single Family
Bathrooms
Outdoor – Multi-Family / High-Rise
Garages, Laundry Rooms and Utility Rooms
7 © 2014 Eaton. All rights reserved.
Kitchens • Must not exceed 50% power • Products that are not High Efficacy, qualify
90CRI Certified to T20
Controls: • High Efficacy and Low Efficacy MUST be separately circuited • Rooms switched from kitchen are considered part of the kitchen • Controls are NOT required but recommended
Coming Soon
SLD LED EL4 LED ELG4 LED ML56 LED HU10 LED RL56 LED RL4 LED
Non-Incandescent IC/AT Housings
H457 H457R H750 H750R H724G24 H724RGU24 P3
80CRI LED / Non-T20 Ballasts
IC/AT Housings RA56 LED P3LED
806/07 Low Efficacy ML56LED HU20 LED LV/H SCN WN
H7 H7R H36/38 H36R H570 H571R
• ≥50% Power must be high efficacy • CFL luminaires with T20 ballasts, GU-24, T20 LED luminaires • IC/AT recessed housing GU-24 & non-incandescent • Linear Fluorescent with T20 certified ballast
High Efficacy Low Efficacy
Coming Soon
8 © 2014 Eaton. All rights reserved.
Bathrooms • At least 1 luminaire must be high efficacy • CFL luminaires with T20 ballasts, GU-24, T20 LED luminaires • IC/AT recessed housing GU-24 & non-incandescent • Linear Fluorescent with T20 certified ballast
• Separate circuit from High Efficacy • Products that are not High Efficacy, qualify
Controls: • High Efficacy and Low Efficacy MUST be separately circuited • Low Efficacy controlled by T20 Vacancy Sensor
80CRI LED / Non-T20 Ballasts
ONW VNW
90CRI Certified to T20 Coming
Soon
SLD LED EL4 LED ELG4 LED ML56 LED HU10 LED RL56 LED RL4 LED
Non-Incandescent IC/AT Housings
H457 H457R H750 H750R H724G24 H724RGU24 P3
RA56 LED P3LED
806/07 Low Efficacy ML56LED HU20 LED 601 600 WN
IC/AT Housings
H7 H7R H36/38 H36R H570 H571R
High Efficacy Low Efficacy
Coming Soon
9 © 2014 Eaton. All rights reserved.
Garages, Laundry, Utility Rooms • ALL luminaires must be High Efficacy • CFL luminaires with T20 ballasts, GU-24, T20 LED luminaires • IC/AT recessed housing GU-24 & non-incandescent • Linear Fluorescent with T20 certified ballast
• Not allowed
Controls: • T20 Vacancy Sensor
ONW VAC
90CRI Certified to T20 Coming
Soon
SLD LED EL4 LED ELG4 LED ML56 LED HU10 LED RL56 LED RL4 LED
Non-Incandescent IC/AT Housings
H457 H457R H750 H750R H724G24 H724RGU24 P3
RA56 LED
H995
High Efficacy Low Efficacy
10 © 2014 Eaton. All rights reserved.
Other Rooms (Not previously covered)
• Can be ALL High Efficacy and controls not required • CFL luminaires with T20 ballasts, GU-24, T20 LED luminaires • IC/AT recessed housing GU-24 and non-incandescent • Linear Fluorescent with T20 certified ballast
• If Low Efficacy, must be controlled • Products that are not High Efficacy, qualify
Controls: • Low Efficacy MUST be separately circuited • Low Efficacy MUST be controls by a vacancy sensor OR dimmer ONW VNW CLS
80CRI LED / Non-T20 Ballasts
IC/AT Housings
806/07 Low Efficacy ML56LED HU20 LED H2522/23 SCN 240
WN H2524
H7 H7R H36/38 H36R H570 H571R
90CRI Certified to T20 Coming
Soon
Non-Incandescent IC/AT Housings
H457 H457R H750 H750R H724G24 H724RGU24 P3
RA56 LED P3LED
SLD LED EL4 LED ELG4 LED ML56 LED HU10 LED RL56 LED RL4 LED
High Efficacy Low Efficacy
Coming Soon
11 © 2014 Eaton. All rights reserved.
Single Family Outdoor (Attached to any building)
High Efficacy • Can be ALL High Efficacy and controls not required • CFL luminaires with T20 ballasts, GU-24, T20 LED
luminaires, High Pressure Sodium, Pulse Start Metal Halide <150W, T20 Pulse Start Metal Halide ≥ 150W
• IC/AT recessed housing GU-24 and non-incandescent • Linear Fluorescent with T20 certified ballast
Low Efficacy • If not High Efficacy, must be controlled
Certified to T20 / Non-Incandescent IC/AT
LED, INC, CFL, and HID
Controls: • Low Efficacy manual ON/OFF does not override ON automatic actions • When Low Efficacy, T20 Motion Sensor AND T20 Photocontrol, T20 Astronomical Time Clock, or EMS
FE VT GP FSL MS MST XTOR
714 903 303
HID / CFL
W PFL23 MD FFL23
SLD LED ML56 LED RL56 LED H457 H457R H750 H750R
12 © 2014 Eaton. All rights reserved.
Low-Rise Multi-Family Outdoor (Can comply with non-residential compliance instead)
• Can be ALL High Efficacy and controls not required • CFL luminaires with T20 ballasts, GU-24, T20 LED
luminaires, High Pressure Sodium, Pulse Start Metal Halide <150W, T20 Pulse Start Metal Halide ≥ 150W
• IC/AT recessed construction when used: GU-24 and non-incandescent
• Linear Fluorescent with T20 certified ballast
• If not High Efficacy, must be controlled
Certified to T20 / Non-Incandescent IC/AT
LED, INC, CFL, and HID
Controls: • Low Efficacy manual ON/OFF does not override ON automatic actions • When Low Efficacy, T20 Motion Sensor AND T20 Photocontrol, T20 Astronomical Time Clock, or EMS
FE VT GP FSL MS MST XTOR
714 903 303
HID / CFL
W PFL23 MD FFL23
High Efficacy Low Efficacy
SLD LED ML56 LED RL56 LED H457 H457R H750 H750R
13 © 2014 Eaton. All rights reserved.
High-Rise Family Outdoor (Attached to the building)
High Efficacy Low Efficacy
Controls: • High-Rise, considered residential when switched from inside dwelling • Low Efficacy manual ON/OFF does not override ON automatic actions • When Low Efficacy, T20 Motion Sensor AND T20 Photocontrol, T20 Astronomical Time Clock, or EMS
Certified to T20 / Non-Incandescent IC/AT
LED, INC, CFL, and HID
FE VT GP FSL MS MST XTOR
714 903 303
HID / CFL
W PFL23 MD FFL23
• Can be ALL High Efficacy and controls not required • CFL luminaires with T20 ballasts, GU-24, T20 LED
luminaires, High Pressure Sodium, Pulse Start Metal Halide <150W, T20 Pulse Start Metal Halide ≥ 150W
• IC/AT recessed housing GU-24 and non-incandescent • Linear Fluorescent with T20 certified ballast
• If not High Efficacy, must be controlled
SLD LED ML56 LED RL56 LED H457 H457R H750 H750R
14 © 2014 Eaton. All rights reserved.
References • California Title 20 Appliance Database search tool
(http://www.appliances.energy.ca.gov/Default.aspx)
• California Title 24 2013 Building Energy Efficiency Standards main website (http://www.energy.ca.gov/title24/2013standards/)
• California Title 24 2013 Residential Compliance Manual website (http://www.energy.ca.gov/title24/2013standards/residential_manual.html)
• California Title 24 2013 Residential Compliance Manual Residential Lighting document (http://www.energy.ca.gov/2013publications/CEC-400-2013-001/chapters/06_Residential_Lighting.pdf)
15 © 2014 Eaton. All rights reserved.
top related