BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Project Designer:
Report Prepared by:
Job Number:
Date:
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2019 Building Energy Efficiency Standards.
This program developed by EnergySoft Software – www.energysoft.com.
573 Oak DriveBernard Parker & Assoc.
Sacramento, CA 95000(415) 256-5555
7188 Pleasant WayZNE Example
Los Angeles, CA 90000
1025 5th St.EnergySoft
Martyn Dodd
Novato, CA 94945(415) 897-6400
M52000
11/1/2019
TABLE OF CONTENTS
Project SummaryEnergy Use Summary
Cover PageTable of ContentsForm CF1R-PRF-01-E Certificate of ComplianceForm ECON-2 Energy Upgrade Recommendations
1617
123
15
This
Cer
tific
ate
of C
ompl
ianc
e is
not
regi
ster
ed CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name: ZNE Example Calculation Date/Time: 2019-11-01T12:04:38-07:00 (Page 1 of 12)
Calculation Description: Title 24 Analysis Input File Name: ZNE Sample.ribd19x
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.002Schema Version: rev 20190401
Report Generated: 2019-11-01 12:05:45
GENERAL INFORMATION
01 Project Name ZNE Example
02 Run Title Title 24 Analysis
03 Project Location 7188 Pleasant Way
04 City Los Angeles 05 Standards Version 2019
06 Zip code 90000 07 Software Version EnergyPro 8.0
08 Climate Zone 9 09 Front Orientation (deg/ Cardinal) 90
10 Building Type SingleFamily 11 Number of Dwelling Units 1
12 Project Scope NewConstruction 13 Number of Bedrooms 3
14 New Cond. Floor Area (ft2) 0 15 Number of Stories 2
16 Existing Cond. Floor Area (ft2) n/a 17 Fenestration Average U-factor 0.3
18 Total Cond. Floor Area (ft2) 2000 19 Glazing Percentage (%) 19.50%
20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
This
Cer
tific
ate
of C
ompl
ianc
e is
not
regi
ster
ed CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name: ZNE Example Calculation Date/Time: 2019-11-01T12:04:38-07:00 (Page 2 of 12)
Calculation Description: Title 24 Analysis Input File Name: ZNE Sample.ribd19x
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.002Schema Version: rev 20190401
Report Generated: 2019-11-01 12:05:45
ENERGY DESIGN RATING
Energy Design Ratings Compliance Margins
Efficiency¹ (EDR) Total² (EDR) Efficiency¹ (EDR) Total² (EDR)
Standard Design 51.2 28
Proposed Design 49.6 0 1.6 28
RESULT: 3: COMPLIES
¹ Efficiency measures include improvements like a better building envelope and more efficient equipment² Total EDR includes efficiency, photovoltaics and batteries³ Building complies when all efficiency and total margins are greater than or equal to zero
• Standard Design PV Capacity: 2.69 kW• PV kWh output exceeds proposed electric use by 15% which may violate NEM rules. Contact your utility.• EDR is capped at zero
ENERGY USE SUMMARY
Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement
Space Heating 7.21 7.08 0.13 1.8
Space Cooling 25.02 21.88 3.14 12.5
IAQ Ventilation 2.56 2.56 0 0
Water Heating 12.6 12.45 0.15 1.2
Self Utilization Credit n/a 0 0 n/a
Compliance Energy Total 47.39 43.97 3.42 7.2
REQUIRED PV SYSTEMS
01 02 03 04 05 06 07 08 09 10 11
DC System Size(kWdc) Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)Tilt
InputArray Angle
(deg) Tilt: (x in 12) Inverter Eff.(%)
1.5 NA Standard Fixed (open rack) none true n/a n/a n/a n/a 96
1.5 NA Standard Fixed (open rack) none true n/a n/a n/a n/a 96
This
Cer
tific
ate
of C
ompl
ianc
e is
not
regi
ster
ed CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name: ZNE Example Calculation Date/Time: 2019-11-01T12:04:38-07:00 (Page 3 of 12)
Calculation Description: Title 24 Analysis Input File Name: ZNE Sample.ribd19x
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.002Schema Version: rev 20190401
Report Generated: 2019-11-01 12:05:45
2 NA Standard Fixed (open rack) none true n/a n/a n/a n/a 96
ENERGY DESIGN RATING BATTERY INPUTS
01 02 03 04 05 06
Control Capacity (kWh) Efficiency Rate (kW)Rate (kW) Efficiency Rate (kW)Rate (kW)
Basic 10 0.95 n/a 0.95 n/a
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• PV System: 5 kWdc• Battery System: 10 kWh• Insulation below roof deck• Non-standard duct location (any location other than attic)• Central parallel piping• Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additionaldetail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building-level Verifications:• Quality insulation installation (QII)• Building Envelope Air Leakage• IAQ mechanical ventilation• Kitchen range hoodCooling System Verifications:• Minimum Airflow• Fan Efficacy Watts/CFMHeating System Verifications:• -- None --HVAC Distribution System Verifications:• Duct Sealing• Ducts located entirely in conditioned space confirmed by duct leakage testingDomestic Hot Water System Verifications:• -- None --
This
Cer
tific
ate
of C
ompl
ianc
e is
not
regi
ster
ed CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name: ZNE Example Calculation Date/Time: 2019-11-01T12:04:38-07:00 (Page 4 of 12)
Calculation Description: Title 24 Analysis Input File Name: ZNE Sample.ribd19x
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.002Schema Version: rev 20190401
Report Generated: 2019-11-01 12:05:45
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Project Name Conditioned Floor Area (ft2)Number of Dwelling
Units Number of Bedrooms Number of Zones Number of VentilationCooling Systems
Number of WaterHeating Systems
ZNE Example 2000 1 3 2 0 1
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2
1st Floor Zone Conditioned Ground Coupled HP1 1200 8 DHW Sys 1 N/A
2nd Floor Zone Conditioned Ground Coupled HP1 800 8 DHW Sys 1 N/A
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door
Area (ft2) Tilt (deg)
Front Wall 1st Floor Zone R-19 Wall w/1 XPS 270 Right 320 81 90
Left Wall 1st Floor Zone R-19 Wall w/1 XPS 0 Front 240 40 90
Back Wall 1st Floor Zone R-19 Wall w/1 XPS 90 Left 320 88.7 90
Right Wall 1st Floor Zone R-19 Wall w/1 XPS 180 Back 240 32 90
Front Wall 2 2nd Floor Zone R-19 Wall w/1 XPS 270 Right 320 60 90
Left Wall 2 2nd Floor Zone R-19 Wall w/1 XPS 0 Front 240 24 90
BackWall 2nd Floor Zone R-19 Wall w/1 XPS 90 Left 320 70 90
Right Wall 2 2nd Floor Zone R-19 Wall w/1 XPS 180 Back 240 32 90
Wall to Garage 1st FloorZone>>__Garage__ R-13 Wall n/a n/a 100 20 n/a
R-38 Roof 1st Floor Zone R-38+13 HP Attic n/a n/a 500 n/a n/a
R-38 Roof 2 2nd Floor Zone R-38+13 HP Attic n/a n/a 800 n/a n/a
GarageRoof __Garage__ R-30 Roof Attic n/a n/a 340 n/a n/a
This
Cer
tific
ate
of C
ompl
ianc
e is
not
regi
ster
ed CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name: ZNE Example Calculation Date/Time: 2019-11-01T12:04:38-07:00 (Page 5 of 12)
Calculation Description: Title 24 Analysis Input File Name: ZNE Sample.ribd19x
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.002Schema Version: rev 20190401
Report Generated: 2019-11-01 12:05:45
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door
Area (ft2) Tilt (deg)
Interior Floor 2nd Floor Zone R-0 Floor No Crawlspace n/a n/a 700 n/a n/a
Floor over Garage 2nd Floor Zone R-19 Floor No Crawlspace n/a n/a 100 n/a n/a
GarageWallFront __Garage__ Garage Ext Wall 270 Right 180 128 90
GarageWallLeft __Garage__ Garage Ext Wall 0 Front 198 0 90
GarageWallRight __Garage__ Garage Ext Wall 180 Back 108 0 90
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise (x in 12) Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic __Garage__ Attic Garage Roof Cons Ventilated 4 0.1 0.85 Yes No
Attic 1st Floor Zone Attic Roof1st FloorZone Ventilated 4 0.1 0.85 Yes No
Attic 2nd Floor Zone Attic Roof2nd FloorZone Ventilated 4 0.1 0.85 Yes No
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width (ft) Height (ft) Mult.Area(ft2)
U-factor U-factorSource SHGC SHGC
SourceExteriorShading
Front Windows Window Front Wall Right 0 1 60 0.3 NFRC 0.23 NFRC Insect Screen(default)
Left Windows Window Left Wall Front 90 1 40 0.3 NFRC 0.23 NFRC Insect Screen(default)
Back Windows Window Back Wall Left 180 1 72 0.3 NFRC 0.23 NFRC Insect Screen(default)
Right Windows Window Right Wall Back 270 1 32 0.3 NFRC 0.23 NFRC Insect Screen(default)
This
Cer
tific
ate
of C
ompl
ianc
e is
not
regi
ster
ed CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name: ZNE Example Calculation Date/Time: 2019-11-01T12:04:38-07:00 (Page 6 of 12)
Calculation Description: Title 24 Analysis Input File Name: ZNE Sample.ribd19x
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.002Schema Version: rev 20190401
Report Generated: 2019-11-01 12:05:45
FENESTRATION / GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width (ft) Height (ft) Mult.Area(ft2)
U-factor U-factorSource SHGC SHGC
SourceExteriorShading
Front Windows2 Window Front Wall 2 Right 0 1 60 0.3 NFRC 0.23 NFRC Insect Screen
(default)
Left Windows 2 Window Left Wall 2 Front 90 1 24 0.3 NFRC 0.23 NFRC Insect Screen(default)
Back Windows2 Window BackWall Left 180 1 70 0.3 NFRC 0.23 NFRC Insect Screen
(default)
Right Windows2 Window Right Wall 2 Back 270 1 32 0.3 NFRC 0.23 NFRC Insect Screen
(default)
OPAQUE DOORS
01 02 03 04
Name Side of Building Area (ft2) U-factor
Entry Door Front Wall 21 0.5
Back Door Back Wall 16.7 0.5
Door Wall to Garage 20 0.5
GarageCarDoorFront GarageWallFront 128 0.7
SLAB FLOORS
01 02 03 04 05 06 07
Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value& Depth Carpeted Fraction Heated
Covered Slab 1st Floor Zone 1200 90 None 80% No
GarageSlab __Garage__ 440 54 None 0% No
This
Cer
tific
ate
of C
ompl
ianc
e is
not
regi
ster
ed CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name: ZNE Example Calculation Date/Time: 2019-11-01T12:04:38-07:00 (Page 7 of 12)
Calculation Description: Title 24 Analysis Input File Name: ZNE Sample.ribd19x
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.002Schema Version: rev 20190401
Report Generated: 2019-11-01 12:05:45
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total CavityR-value
Interior / ExteriorContinuous
R-valueU-factor Assembly Layers
Garage Ext Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C. Noinsulation n/a 0.361
Inside Finish: Gypsum BoardCavity / Frame: no insul. / 2x4Exterior Finish: 3 Coat Stucco
R-19 Wall w/1 XPS Exterior Walls Wood Framed Wall 2x6 @ 16 in. O. C. R 18 n/a 0.051
Inside Finish: Gypsum BoardCavity / Frame: R-19 in 5-1/2 in. (R-18) /
2x6Sheathing / Insulation: R5 Sheathing
Exterior Finish: 3 Coat Stucco
R-13 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C. R-13 n/a 0.092Inside Finish: Gypsum BoardCavity / Frame: R-13 / 2x4
Other Side Finish: Gypsum Board
Attic Garage Roof Cons Attic Roofs Wood FramedCeiling 2x4 @ 24 in. O. C. No
insulation n/a 0.644
Cavity / Frame: no insul. / 2x4Roof Deck: Wood
Siding/sheathing/deckingRoofing: Light Roof (Asphalt Shingle)
Attic Roof1st Floor Zone Attic Roofs Wood FramedCeiling 2x4 @ 24 in. O. C. R-13 n/a 0.078
Around Roof Joists: R-0.0 insul.Cavity / Frame: R-13.0 / 2x4
Roof Deck: WoodSiding/sheathing/decking
Roofing: Light Roof (Asphalt Shingle)
Attic Roof2nd FloorZone Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in. O. C. R-13 n/a 0.078
Around Roof Joists: R-0.0 insul.Cavity / Frame: R-13.0 / 2x4
Roof Deck: WoodSiding/sheathing/decking
Roofing: Light Roof (Asphalt Shingle)
R-30 Roof Attic Ceilings (belowattic)
Wood FramedCeiling 2x4 @ 24 in. O. C. R-30 n/a 0.032
Inside Finish: Gypsum BoardCavity / Frame: R-9.1 / 2x4
Over Ceiling Joists: R-20.9 insul.
This
Cer
tific
ate
of C
ompl
ianc
e is
not
regi
ster
ed CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name: ZNE Example Calculation Date/Time: 2019-11-01T12:04:38-07:00 (Page 8 of 12)
Calculation Description: Title 24 Analysis Input File Name: ZNE Sample.ribd19x
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.002Schema Version: rev 20190401
Report Generated: 2019-11-01 12:05:45
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
Construction Name Surface Type Construction Type Framing Total CavityR-value
Interior / ExteriorContinuous
R-valueU-factor Assembly Layers
R-38+13 HP Attic Ceilings (belowattic)
Wood FramedCeiling 2x4 @ 24 in. O. C. R-38 n/a 0.025
Inside Finish: Gypsum BoardCavity / Frame: R-9.1 / 2x4
Over Ceiling Joists: R-28.9 insul.
R-0 Floor No Crawlspace Interior Floors Wood Framed Floor 2x12 @ 16 in. O. C. Noinsulation n/a 0.196
Floor Surface: CarpetedFloor Deck: Wood
Siding/sheathing/deckingCavity / Frame: no insul. / 2x12
Ceiling Below Finish: Gypsum Board
R-19 Floor NoCrawlspace Interior Floors Wood Framed Floor 2x10 @ 16 in. O. C. R-19 n/a 0.045
Floor Surface: CarpetedFloor Deck: Wood
Siding/sheathing/deckingCavity / Frame: R-19 / 2x10
Ceiling Below Finish: Gypsum Board
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Required 533.3
WATER HEATING SYSTEMS
01 02 03 04 05 06 07 08
Name System Type Distribution Type Water Heater Number ofHeaters
SolarFraction (%) Compact Distribution HERS Verification
DHW Sys 1 Domestic Hot Water(DHW) Parallel Piping DHW Heater 1 1 0 None n/a
This
Cer
tific
ate
of C
ompl
ianc
e is
not
regi
ster
ed CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name: ZNE Example Calculation Date/Time: 2019-11-01T12:04:38-07:00 (Page 9 of 12)
Calculation Description: Title 24 Analysis Input File Name: ZNE Sample.ribd19x
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.002Schema Version: rev 20190401
Report Generated: 2019-11-01 12:05:45
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
NameHeatingElement
TypeTank Type #
Units
TankVol.(gal)
EnergyFactor orEfficiency
Input Ratingor Pilot
TankInsulation
R-value(Int/Ext)
Standby Lossor Recovery
Eff.
1st Hr. Ratingor Flow Rate
NEEA Heat PumpBrand or Model /
Other
Tank Location orAmbient Condition
DHW Heater 1 Heat PumpBoiler n/a 1 50 NEEA Rated n/a n/a 82 80\ AOSmith\AOSmith
HP1050 Garage
WATER HEATING - HERS VERIFICATION
01 02 03 04
Name Pipe Insulation Parallel Piping Compact Distribution
DHW Sys 1 - 1/1 Not Required Not Required Not Required
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07
Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Required ThermostatType
Ground Coupled HP1 Heat pump heatingcooling Heat Pump System 1 Heat Pump System 1 HVAC Fan 1 Air Distribution System 1 Setback
HVAC - HEAT PUMPS
01 02 03 04 05 06 07 08 09 10 11
Name System Type Number of UnitsHeating Cooling Zonally
ControlledCompressor
Type HERS VerificationHSPF/COP Cap 47 Cap 17 SEER EER
Heat Pump System 1 Ground sourceheat pump 1 4.8 47500 40000 14 16 Not Zonal Single
SpeedHeat Pump System
1-hers-htpump
This
Cer
tific
ate
of C
ompl
ianc
e is
not
regi
ster
ed CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name: ZNE Example Calculation Date/Time: 2019-11-01T12:04:38-07:00 (Page 10 of 12)
Calculation Description: Title 24 Analysis Input File Name: ZNE Sample.ribd19x
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.002Schema Version: rev 20190401
Report Generated: 2019-11-01 12:05:45
HVAC HEAT PUMPS - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Verified Airflow Airflow Target Verified EER Verified SEER Verified RefrigerantCharge Verified HSPF Verified Heating
Cap 47Verified Heating
Cap 17
Heat Pump System1-hers-htpump Required 350 Not Required Not Required No No No No
HVAC - DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
Duct Ins.R-value Duct Location Surface Area
Name Type Design Type Suppy Return Supply Return Supply Return BypassDuct Duct Leakage HERS Verification
Air DistributionSystem 1
Conditionedspace-entirely Non-Verified R-8 R-8 Conditioned
ZoneConditioned
Zone 0 0No
BypassDuct
Sealed andTested
Air Distribution System1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Duct LeakageVerification
Duct leakage target(%)
Verified DuctLocation
Verified DuctDesign Buried Ducts Deeply Buried
DuctsLow-leakage Air
Handler
Low Leakage DuctsEntirely in
Conditioned Space
Air DistributionSystem 1-hers-dist Yes 5 Required Not Required Not Required Credit not taken Required No
HVAC - FAN SYSTEMS
01 02 03 04
Name Type Fan Power (Watts/CFM) Name
HVAC Fan 1 Single speed PSC furnace fan 0.45 HVAC Fan 1-hers-fan
This
Cer
tific
ate
of C
ompl
ianc
e is
not
regi
ster
ed CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name: ZNE Example Calculation Date/Time: 2019-11-01T12:04:38-07:00 (Page 11 of 12)
Calculation Description: Title 24 Analysis Input File Name: ZNE Sample.ribd19x
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.002Schema Version: rev 20190401
Report Generated: 2019-11-01 12:05:45
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Power(Watts/CFM)
HVAC Fan 1-hers-fan Required 0.45
IAQ (INDOOR AIR QUALITY) FANS
01 02 03 04 05 06
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%) HERS Verification
SFam IAQVentRpt 88 0.25 Default 0 Yes
This
Cer
tific
ate
of C
ompl
ianc
e is
not
regi
ster
ed CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
Project Name: ZNE Example Calculation Date/Time: 2019-11-01T12:04:38-07:00 (Page 12 of 12)
Calculation Description: Title 24 Analysis Input File Name: ZNE Sample.ribd19x
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.002Schema Version: rev 20190401
Report Generated: 2019-11-01 12:05:45
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.Documentation Author Name: Documentation Author Signature:
Company: Signature Date:
Address: CEA/ HERS Certification Identification (If applicable):
City/State/Zip: Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENTI certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.2. I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.Responsible Designer Name: Responsible Designer Signature:
Company: Date Signed:
Address: License:
City/State/Zip: Phone:
Martyn Dodd
EnergySoft
1025 5th St.
Novato, CA 94945
KKJII
(415) 897-6400
11/1/2019
Rob Parker
Bernard Parker & Assoc.
573 Oak Drive
Sacramento, CA 95000 (415) 256-5555
Energy Upgrade Recommendations ECON-2 Project Name Documentation Author Project Address Author Address
Recommended Improvements Description
Annual Savings
Est. Cost to Install
Savings
Site TDV
Annual Results Energy Cost
Electricity (kWh)
Fossil Fuel (therms)
End Use Existing Improved Savings Existing Improved Savings Existing Improved Savings
Space Heating
Space Cooling
Fans
Pumps
Domestic Hot Water
Indoor Lighting
Outdoor Lighting
Plug Loads
Appliances/Ancillary
TOTAL
CO2 (metric tons/year) Existing Improved Savings Climate Zone:
Electricity Electric Rate:
Fossil Fuel Gas Rate:
TOTAL Floor Area:
Type:
Average Demand (kW)
TDV Energy (kBtu/ft2-yr)
The estimated operating costs shown in this report are dependent upon many factors. The construction and conservation features of the project clearly are important. Equally important is the thermostat setting. How the thermostat is used, appliance use, and occupant interaction all influence the annual operating cost. The estimates provided in this report are based on typical conditions; your actual usage will vary.
7188 Pleasant WayLos Angeles, CA 90000
ZNE Example
$14
$0
$51$23
$72
$59$121
($720)
$247$243
$110
ID: M52000 Page 15 of 17EnergyPro 8.0.1.1 by EnergySoft User Number: 0000
1025 5th St.Novato, CA 94945
EnergySoft
0
0
00
0
00
0
00
0
114
0
420192
588
487993
-7,895
2,0261,994
-1,080
0.07
0.070.00
6.23
Electric Alameda HGas PG&E P
9
2,000Single Family
-5.98
Photovoltaic+Battery
Project Summary
Date of Audit: House Type:
Conditioned Floor Area: Foundation Type:
Number of Stories: Climate Zone:
Number of Bedrooms: Weather Data:
WHERE THE ENERGY IS USED
This pie chart estimates the energy cost for the
various types of end uses in the home. Data has
been calculated using software that uses typical
profiles of usage to estimate end use cost. Your
costs may vary from these numbers depending
upon how the home is operated.
This all electric home was evaluated with QII and a significant solar system and battery included as well as mostfeatures needed to comply with the 2019 Title 24 code requirements.
1
2,000
3
9
Single Family
Slab-on-Grade
CZ09_wy3.bin
Los Angeles, CA 90000
7188 Pleasant Way
EnergyPro 8.0 by EnergySoft Page 16 of 17User Number: 0000 ID: M52000
Energy Use Summary
ELECTRICITY
End Use kWh/yr
Space Heating
Space Cooling
Fans
Pumps
Domestic Hot Water
Indoor Lighting
Outdoor Lighting
Plug Loads
Appliances/Ancillary
Renewables
TOTAL
FOSSIL FUEL
End Use Therms/yr
Space Heating
Domestic Hot Water
Appliances
Ancillary
TOTAL
The tables and graphs below summarize the major energy uses in the home for both electricity and fossil fuels. Ancillary
uses include swimming pools and spas.
Los Angeles, CA 90000
7188 Pleasant Way
114
588
420
192
0
993
487
2,026
1,994
-1,080
0
0
0
0
-7,895
0
EnergyPro 8.0 by EnergySoft Page 17 of 17User Number: 0000 ID: M52000