BASE FLOOR PLAN WL - Western Washington University · UPPER FOURTH FLOOR EXTERIOR SPACE ROOF BELOW. 577570B 578B 579 570 574573 571 572 563B 563C 563 564 568 567 562 566 566A565A
Post on 20-Jun-2020
1 Views
Preview:
Transcript
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED UNEXCAVATED
UNEXCAVATED
173A
172176
174
170C
164E
164F
164C 163D
163163B
163C
162B
162162A
182C
181 182182B
182A
197
195193
194
192
191
196
198185
180
160 161
190A
190
190B
186184183
188
188C188B
178
178C 178B171
DN
DN
UP
UP
UP
DN
UP
UP
UPUP
UP
DN
UP
170J 170K170L 170A
170B
170D170
170G 170F 170E170H
165
166 167
165A164
164A
DN
BASE FLOOR PLAN
NTRUENORTHFT
Western Washington University (WWU) makes these documents available on an"as is" basis. All warranties and representations of any kind with regard to saiddocuments are disclaimed, including the implied warranties of merchantability andfitness for a particular use. WWU does not warrant the documents againstdeficiencies of any kind.
0 10 20
Building
Floor #
Last Drawing Revision: 05/05/2020 Last Sync With AIM: 04/12/2019
FLOOR 1 WILSON LIBRARY
1WL
SKYBRIDGE TOHAGGARD HALL
276
275
274
273
272
271
270B 270A
267A
267
265B
265A
270
268
263B
263C
265
261A 261
262
291
283B283A
281B
282
279A
279
281A
280A
281
280
288
288B
283C 290B
290A
290
263
278C
278B
278
UP
DN
UP
DN
UP
UP
DN
UP
DN
UP
DN
283
DNDN
X281
278A
263A
288A
DN UPDN
290C
UP
BASE FLOOR PLAN
NTRUENORTHFT
Western Washington University (WWU) makes these documents available on an"as is" basis. All warranties and representations of any kind with regard to saiddocuments are disclaimed, including the implied warranties of merchantability andfitness for a particular use. WWU does not warrant the documents againstdeficiencies of any kind.
0 10 20
Building
Floor #
Last Drawing Revision: 05/05/2020 Last Sync With AIM: 09/28/2018
FLOOR 2 WILSON LIBRARY
2WL
UPPER HH260
OPEN TO 261 BELOW
UPPER SECOND FLOOR
UPPER 262
377 370B 373 374 375 376
379
378B
370
370A
363B 363C363
364
367B
367366
367A 365A365
362361 361A
390B
390
391
388B
392
389
389A
UP
DN
UP
DN
UPDN
DN
UP
DN
UP
DN
DNUP
X390X370
BASE FLOOR PLAN
NTRUENORTHFT
Western Washington University (WWU) makes these documents available on an"as is" basis. All warranties and representations of any kind with regard to saiddocuments are disclaimed, including the implied warranties of merchantability andfitness for a particular use. WWU does not warrant the documents againstdeficiencies of any kind.
0 10 20
Building
Floor #
Last Drawing Revision: 05/05/2020 Last Sync With AIM: 02/09/2017
FLOOR 3 WILSON LIBRARY
3WL
477 470B
470
463B463C
470A
463 462
464
467
466A 465A
466 465
461
495
484485
479C
479B
479A479
483482482A
481A 481
470C
478B
478
490B
488B
488
490
490A
494493492491
480
DN
UP
UP
UP
DN
UPDN
DN
UP
DN
UP
UP
DN
UP UP
X470 X490
BASE FLOOR PLAN
NTRUENORTHFT
Western Washington University (WWU) makes these documents available on an"as is" basis. All warranties and representations of any kind with regard to saiddocuments are disclaimed, including the implied warranties of merchantability andfitness for a particular use. WWU does not warrant the documents againstdeficiencies of any kind.
0 10 20
Building
Floor #
Last Drawing Revision: 05/05/2020 Last Sync With AIM: 02/09/2017
FLOOR 4 WILSON LIBRARY
4WL
EXTERIOR SPACE UPPER FOURTHFLOOR EXTERIOR SPACE
ROOF BELOW
577 570B
578B
579
570
574 573
571
572
563B563C
563
564
568
567
562
566
566A 565A
565
561
589
590A
590
588B
591
592
UP
DN
X590
X570
UP
DN
DNUP
DN
UP
DN
BASE FLOOR PLAN
NTRUENORTHFT
Western Washington University (WWU) makes these documents available on an"as is" basis. All warranties and representations of any kind with regard to saiddocuments are disclaimed, including the implied warranties of merchantability andfitness for a particular use. WWU does not warrant the documents againstdeficiencies of any kind.
0 10 20
Building
Floor #
Last Drawing Revision: 05/05/2020 Last Sync With AIM: 02/09/2017
FLOOR 5 WILSON LIBRARY
5WL
UPPER 480
UPPER FOURTH FLOOR
ROOF BELOW ROOF BELOW
ROOF BELOW ROOF
ROOF
LADDER (TYP.)
SLOPING CEILING
SLOPING CEILING
SLOPING CEILING
ROOF
677
670B
679
680A
680
676A
671
676
673674
675
672663B
663
662
664
665666
667668669
678D 678C
678A
678B 688B
688A
687
686
DN
X677
X676
DN
DN DN
BASE FLOOR PLAN
NTRUENORTHFT
Western Washington University (WWU) makes these documents available on an"as is" basis. All warranties and representations of any kind with regard to saiddocuments are disclaimed, including the implied warranties of merchantability andfitness for a particular use. WWU does not warrant the documents againstdeficiencies of any kind.
0 10 20
Building
Floor #
Last Drawing Revision: 05/05/2020 Last Sync With AIM: 02/09/2017
FLOOR 6 WILSON LIBRARY
6WL
HATCH FROM663 BELOW
HATCH FROM 670B BELOW
ROOF BELOW
ROOF
ROOF
ROOF
ROOF BELOW ROOF BELOW ROOF BELOWUPPER FOURTH FLOOR
ROOF
LADDER (TYP.)
OPEN CEILING OVER SIXTH FLOOR
SLOPING CEILING SLOPING CEILING
SLOPING CEILING
ROOF BELOW
762763
761
UP
UPPER SIXTH FLOOR
BASE FLOOR PLAN
NTRUENORTHFT
Western Washington University (WWU) makes these documents available on an"as is" basis. All warranties and representations of any kind with regard to saiddocuments are disclaimed, including the implied warranties of merchantability andfitness for a particular use. WWU does not warrant the documents againstdeficiencies of any kind.
0 10 20
Building
Floor #
Last Drawing Revision: 05/05/2020 Last Sync With AIM: 02/09/2017
ATTIC WILSON LIBRARY