Srikanth Kandula, Sudipta Sengupta, Albert Greenberg, Parveen Patel, Ronnie Chaiken

Microsoft ResearchIMC November, 2009

Abhishek Rayraya@cs.ucr.edu

THE NATURE OF DATACENTER: MEASUREMENTS & ANALYSIS

OutlineIntroductionData & MethodologyApplicationTraffic CharacteristicsTomographyConclusion

IntroductionAnalysis and mining of data sets

Processing around some petabytes of data

This paper has tried to describe characteristics of traffic Detailed view of traffic Congestion conditions and patterns

ContributionMeasurement Instrumentation

Measures traffic at data centers rather than switches

Traffic characteristics Flow, congestion and rate of change of traffic mix.

Tomography Inference Accuracy Performs

Clusters =1500 servers Rack = 20

2 months

Data & MethodologyISPs

SNMP CountersSampled FlowDeep packet Inspection

Data CenterMeasurements at Server

Servers, Storage and networkLinkage of network traffic with application level

logs

Socket level events at each serversETW – Event Tracing for Windows

One per application read or write

Aggregates over several packets

http://msdn.microsoft.com/en-us/magazine/cc163437.aspx#S1

ETW – Event tracing for Windows

Application WorkloadSQL Programming language like Scope3 phases of different types

Extract PartitionAggregateCombine

Short interactive programs to long running programs

Traffic Characteristics

Patterns

Work-Seeks-BW and Scatter-Gather patterns in datacenter traffic

exchanged b/w server pairs

Work-seeks-bandwidthWithin same serversWithin servers in same rackWithin servers in same VLAN

Scatter-gather-patternsData is divided into small parts and each

servers works on particular partAggregated

How much traffic is exchanged between server pairs?

Server pair with same rack are more likely to exchange more bytes

Probability of exchanging no traffic 89% - servers within same rack99.5% - servers in different rack

How many other servers does a server correspond with?

Sever either talks to all other servers with the same rack

Servers doesn’t talk to servers outside the rack or talks 1-10% outside servers.

Congestion within the Datacenter

N/W at as high an utilization as possible without adversely affecting throughput

Low network utilization indicateApplication by nature demands more of

other resources such as CPU and disk than the network

Applications can be re-written to make better use of available network bandwidth

Where and when the congestion happens in data center

Congestion Rate 86% - 10 seconds 15% - 100 seconds

Short congestion periods are highly correlated across many tens of links and are due to brief spurts of high demand from the application

Long lasting congestion periods tend to be more localized to a small set of links

Length of Congestion Events

Compares the rates of flows that overlap high utilization periods with

the rates of all flows

Impact of high utilization

Read failure - Job is killedCongestion

To attribute network traffic to the applications that generate it, they merge the network event logs with logs at the application-level that describe which job and phase were active at that time

Reduce phase - Data in each partition that is present at multiple servers in the cluster has to be pulled to the server that handles the reduce for the partitione.g. count the number of records that begin with ‘A’

Extract phase – Extracting the dataLargest amount of data

Evaluation phase – Problem

Conclusion – High utilization epochs are caused by application demand and have a moderate negative impact to job performance

Flow Characteristics

Traffic mix changes frequently

How traffic changes over time within the data center

Change in traffic10th and 90th percentiles are 37% and 149% the median change in traffic is roughly 82%

even when the total traffic in the matrix remains the same, the server pairs that are involved in these traffic exchanges change appreciably

Short bursts cause spikes at the shorter time-scale (in dashed line) that smooth out at the longer time scale (in solid line) whereas gradual changes appear conversely, smoothed out at shorter time-scales yet pronounced on the longer time-scale

Variability - key aspect for data center

Inter-arrival times in the entire cluster, at Top-of-Rack switches

and at servers

Inter-arrivals at both servers and top-of-rack switches have spaced apart by roughly 15ms

This is likely due to the stop-and-go behavior of the application that rate-limits the creation of new flows

Median arrival rate of all flows in the cluster is 105 flows per second or 100 flows in every millisecond

TomographyN/W tomography methods to infer traffic matricesIf the methods used in ISP n/w is applicable to

datacenters, it would help to unravel the nature of traffic

Why?Data flow volume is quadratic n(n - 1) – no. of links

measurements are fewer Assumptions - Gravity model - Amount of traffic a

node (origin) would send to another node (destination) is proportional to the traffic volume received by the destination

Scalability

Methodology

Computes ground truth TM and measure how well the TM estimated by tomography from these link counts approximates the true TM

Tomogravity and Spare Maximization

Tomogravity - Communication likely to be B/W nodes with same job rather than all nodes, whereas gravity model, not being aware of these job-clusters, introduces traffic across clusters, resulting in many non-zero TM entries

Spare maximization – Error rate starts from several hundreds

Comparison the TMs by various tomography methods with the

ground truth

Ground TMs are sparser than tomogravity estimated TMs, and denser than sparsity maximized estimated TMs

ConclusionCapture both

Macroscopic patterns – which servers talk to which others, when and for what reasons

Microscopic characteristics – flow durations, inter-arrival times

Tighter coupling between network, computing, and storage in datacenter applications

Congestion and negative application impact do occur, demanding improvement - better understanding of traffic and mechanisms that steer demand

My TakeMore data should be examined over a period

of 1 year instead of 2 monthsI would certainly like to see some mining of

data and application running at datacenters of companies like Google, Yahoo etc

Related WorkT. Benson, A. Anand, A. Akella, andM.

Zhang: Understanding Datacenter Traffic Characteristics, In SIGCOMMWREN workshop, 2009.

A. Greenberg, N. Jain, S. Kandula, C. Kim, P. Lahiri, D. Maltz, P. Patel, and S. Sengupta:

VL2: A Scalable and Flexible Data Center Network, In ACM SIGCOMM, 2009.