2094-IN012C-EN-P Kinetix 6200 and Kinetix 6500 Control ...literature.rockwellautomation.com/idc/groups/literature/documents/... · Refer to Additional Resources on page 12 for user
Post on 16-Apr-2018
238 Views
Preview:
Transcript
Installation Instructions
Kinetix 6200 and Kinetix 6500 Control ModulesCatalog Numbers 2094-SE02F-M00-S0, 2094-SE02F-M00-S1, 2094-EN02D-M01-S0, 2094-EN02D-M01-S1
About the Control ModulesEach integrated axis (IAM) power module and axis (AM) power module requires one control module. Each control module provides user I/O, safety, auxiliary feedback, and motor feedback connections. Kinetix 6200 control modules use sercos interface to communicate with the Logix5000 controller and EtherNet/IP to access the safety configuration tool. Kinetix 6500 control modules use EtherNet/IP for programming the Logix5000 controller and safety configuration tool. In addition, the Kinetix 6200 and Kinetix 6500 control modules are available with either safe torque-off or safe speed monitoring functionality.
Refer to Additional Resources on page 12 for user documentation supporting installation and wiring, integration with ControlLogix, CompactLogix, or SoftLogix controller platforms, troubleshooting, and safety functions.
Topic Page
About the Control Modules 1
Catalog Number Explanation 2
Before You Begin 2
Install the Control Modules 4
Connector Data 6
Motor Overload Protection 11
Additional Resources 12
2 Kinetix 6200 and Kinetix 6500 Control Modules
Catalog Number ExplanationThis publication applies to the Kinetix 6200 and Kinetix 6500 control modules.
Kinetix 6200 Sercos Control Modules
Kinetix 6500 EtherNet/IP Control Modules
Before You BeginRemove all packing material, wedges, and braces from within and around the components. After unpacking, check the item nameplate catalog number against the purchase order.
Each 2094-SE02F-M00-S0 and 2094-EN02D-M01-S0 safe torque-off control module ships with one motion-allowed plug for the IOD connector. Install the 44-pin motion-allowed plug on the IOD connector when the safe torque-off functionality is not used and no other I/O connections are required for your application.
This procedure assumes you have prepared your panel, mounted your Bulletin 2094 power rail, and Bulletin 2094 power modules. For installation instructions regarding equipment and accessories not included here, refer to the instructions that came with those products.
Cat. No. Description
2094-SE02F-M00-S1 Kinetix 6200 control module, sercos fiber optic, safe speed monitoring
2094-SE02F-M00-S0 Kinetix 6200 control module, sercos fiber optic, safe torque-off
Cat. No. Description
2094-EN02D-M01-S1 Kinetix 6500 control module, EtherNet/IP, safe speed monitoring
2094-EN02D-M01-S0 Kinetix 6500 control module, EtherNet/IP, safe torque-off
TIP Connector kits for user I/O, safety, and auxiliary feedback (catalog numbers 2090-K6CK-D44M or 2090-K6CK-D44S0) and motor feedback (catalog number 2090-K6CK-D15M), are not provided. Refer to the Kinetix Motion Accessories Technical Data, publication GMC-TD004, for more information.
ATTENTION: Plan the installation of your system so that you can perform all cutting, drilling, tapping, and welding with the system removed from the enclosure. Because the system is of the open type construction, be careful to keep any metal debris from falling into it. Metal debris or other foreign matter can become lodged in the circuitry and result in damage to components.
Rockwell Automation Publication 2094-IN012C-EN-P - August 2013
http://literature.rockwellautomation.com/idc/groups/literature/documents/td/gmc-td004_-en-p.pdf
Kinetix 6200 and Kinetix 6500 Control Modules 3
Module CompatibilityKinetix 6000 IAM/AM modules and Bulletin 2094 power modules with Kinetix 6200 control modules are completely compatible and can be used together on the same Bulletin 2094 power rail.
Drive/Control Module Compatibility
IMPORTANT Kinetix 6200 (sercos) and Kinetix 6500 (EtherNet/IP) control modules are not compatible and cannot be used on the same Bulletin 2094 power rail.
IAM Module/Control Module IAM Power Module
2094-xMxx-SKinetix 6000AM Module
2094-BMxx-M AM Power Modules
Kinetix 6200Control Module
Kinetix 6500Control Module
2094-xCxx-Mxx-SKinetix 6000 (sercos) N/A
Fully compatible Fully compatible Not compatible2094-SE02F-M00-Sx Kinetix 6200 (sercos)
2094-BCxx-Mxx-M2094-EN02D-M01-Sx Kinetix 6500 (EtherNet/IP) Not compatible Not compatible Fully compatible
Rockwell Automation Publication 2094-IN012C-EN-P - August 2013
4 Kinetix 6200 and Kinetix 6500 Control Modules
Install the Control ModulesThe IAM and AM power modules are equipped with two mounting hooks and a threaded hole. The Bulletin 2094 control modules have two mounting studs, guide pins, and a captive screw for mating the control module with a power module.
Follow these steps to mount Bulletin 2094 control modules to IAM (inverter) power module or AM power modules. In this procedure an IAM power module is shown.
1. Remove all input power from the IAM power module.
Verify that the Power-applied indicator is off. When the indicator is on, voltage is present on the IAM and AM power module signal connectors.
2. Position the control module in front of the power module.
IMPORTANT For convenience and ease of use, mount the IAM and AM power modules on the power rail before mounting the control modules.
When the IAM power modules are placed on a flat surface, with the power-rail connectors facing down, the mounting screw that extends from the front of the drive and fastens to the power rail, pushes back and interferes with the control module installation.
Refer to the Kinetix 6200 and Kinetix 6500 IAM and AM Power Modules Installation Instructions, publication 2094-IN011, for more information.
ATTENTION: To avoid damage to equipment, do not mount your Bulletin 2094 control module to the power module when the Power-applied indicator is on. Remove all input power from the IAM power module before mounting the control module.
IAM or AM Power Module(IAM power module is shown)Captive
Screw
Bulletin 2094 Control Module(Kinetix 6200 control
module is shown)
Threaded Holein Tongue
Mounting Hooks
Mounting Studs(other mounting stud is hidden from view)
Guide Pins
Signal Connectors
Power-applied Indicator
Rockwell Automation Publication 2094-IN012C-EN-P - August 2013
http://literature.rockwellautomation.com/idc/groups/literature/documents/in/2094-in011_-en-p.pdf
Kinetix 6200 and Kinetix 6500 Control Modules 5
3. Align the control module mounting studs so they engage with the power module hooks.
4. Pivot the control module toward the power module to engage the signal connectors and guide pins.
5. Tighten the captive screw.
6. Repeat step 2 through step 5 to mount a control module onto each power module installed on your Bulletin 2094 power rail.
Mounting Hook(right side)
IAM or AM Power Module(IAM power module is shown)
Mounting Stud(right side)
Left-side mounting stud and hook are hidden from view.
Bulletin 2094 Control Module(Kinetix 6200 control
module is shown)
IAM or AM Power Module(IAM power module is shown)
Mounting Stud andHook Engaged(right side)
Guide PinsStraddling Tongue
Guide Pin Alignment onEither Side of Tongue
Left-side mounting stud and hook are hidden from view.
Bulletin 2094 Control Module(Kinetix 6200 control
module is shown)
Captive Screw(apply 1.1 Nm (10 lbin) torque) IAM or AM Power Module
(IAM power module is shown)
Bulletin 2094 Control Module(Kinetix 6200 control
module is shown)
Rockwell Automation Publication 2094-IN012C-EN-P - August 2013
6 Kinetix 6200 and Kinetix 6500 Control Modules
Connector DataUse these illustrations to identify the control module connectors and indicators.
Kinetix 6200 Control Module Features and Indicators (sercos)
24
6
5
3
2
1
12
14
13
15
10
7 8 9
11
Control Module (2094-SE02F-M00-Sx) Top View
Control Module (2094-SE02F-M00-Sx) Front View
Control Module (2094-SE02F-M00-Sx) Bottom View
Item Description
1 Guide pins (2x)
2 Captive screw
3 Sercos communication rate and optical power switches
4 Sercos Transmit (Tx) connector
5 Sercos Receive (Rx) connector
Item Description
6 Four-character status display
7 PORT 1 status Indicator
8 Drive status indicator
9 Comm status indicator
10 DC bus status indicator
11 Safety lock status indicator(only 2094-SE02F-M00-S1 modules)
12 I/O, safety, and aux feedback (IOD) connector
13 Power module mounting screw access hole
14 Motor feedback (MF) connector
Item Description
15 Ethernet (PORT1) connector
Rockwell Automation Publication 2094-IN012C-EN-P - August 2013
Kinetix 6200 and Kinetix 6500 Control Modules 7
Kinetix 6500 Control Module Connectors and Indicators (Ethernet)
Kinetix 6200 and Kinetix 6500 Control Module Connectors
Designator Description Connector
IOD User I/O (drive), safety, and auxiliary feedback 44-pin high-density D-shell
MF Motor feedback 15-pin high-density D-shell
Tx and Rx Sercos connections for controller programming (only Kinetix 6200 modules) Sercos fiber-optic (2x)
PORT1 Ethernet connection for safety configurationRJ45
PORT2 Ethernet connection for controller programming (only Kinetix 6500 modules)
2
3
2
7
4 5 6
1
10
12
11
13
9
8
14
Control Module (2094-EN02D-M01-Sx) Top View
Control Module (2094-EN02D-M01-Sx) Front View
Control Module (2094-EN02D-M01-Sx) Bottom View
Item Description
1 Guide pins (2x)
2 Captive screw
Item Description
3 Four-character status display
4 PORT 1 status indicator
5 PORT 2 status indicator
6 Module status indicator
7 Network status indicator
8 DC bus status indicator
9 Safety lock status indicator(only 2094-EN02D-M01-S1 modules)
10 I/O, safety, and aux feedback (IOD) connector
11 Power module mounting screw access hole
12 Motor feedback (MF) connector
Item Description
13 Ethernet (PORT1) connector
14 Ethernet (PORT2) connector
Rockwell Automation Publication 2094-IN012C-EN-P - August 2013
8 Kinetix 6200 and Kinetix 6500 Control Modules
IOD Connector PinoutsThis is the IOD connector pinout for safe speed monitoring (-S1) control modules.
Catalog Numbers 2094-SE02F-M00-S1 and 2094-EN02D-M01-S1
Refer to the Kinetix 6200 and Kinetix 6500 Safe Speed Monitoring Safety Reference Manual, publication 2094-RM001, for signal descriptions and more information on safe-speed monitoring safety functions.
ATTENTION: To avoid damage to the sercos Rx and Tx connectors, use only finger-tight torque when attaching the fiber-optic cables to the Kinetix 6200 control modules. Do not use a wrench or any other mechanical assistance.
For more information, refer to Fiber-optic Cable Installation and Handling Instructions, publication 2090-IN010.
IOD (1) Pin
(1) Designators in parenthesis refer to the Guardmaster MSR57P safety relay and PowerFlex 750-Series safety option terminals.
Signal IOD Pin Signal IOD (1)
Pin SignalIOD (1)
Pin Signal
0 12
23 (S52) SLS_IN_CH0
33 (X32) LM_IN_CH0
1 AUX_SIN+AUX_A+ 13 34 (X42) LM_IN_CH1
2 AUX_SIN-AUX_A- 14 24VPWR (2)
(2) Signals 24VPWR and 24VCOM (IOD-14 and IOD-15) apply to only the 2094-SE02F-M00-S0 or 1094-EN02D-M01-S0 (safe torque-off) control modules.
24 (S62) SLS_IN_CH1 35 (51) DC_OUT_CH0
3 AUX_COS+AUX_B+ 15 24VCOM (2) 25 RESET_REF 36 (52) DC_OUT_CH1
4 AUX_COS-AUX_B- 16 26 (S34) RESET_IN 37 (S72) ESM_IN_CH0
5 AUX_DATA+AUX_I+ 17 (A1) SPWR 27 (S11) TEST_OUT_0 38 (S82) ESM_IN_CH1
6 AUX_DATA-AUX_I- 18 (A2) SCOM 28 (S21) TEST_OUT_1 39 24VPWR (3)
(3) Signals 24VPWR and 24VCOM (IOD-39 and IOD-40) are a 24V DC source you can use to operate the digital inputs (50 mA maximum per input).
7 AUX_CLK+ 19 (S12) SS_IN_CH0 29 (68) SLS_OUT_CH0 40 24VCOM (3)
8 AUX_CLK- 20 (S22) SS_IN_CH1 30 (78) SLS_OUT_CH1 41 INPUT1
9 EPWR_5V 21 (34) SS_OUT_CH0 31 (S32) DM_IN_CH0 42 INPUT2
10 ECOM22 (44) SS_OUT_CH1 32 (S42) DM_IN_CH1
43 INPUT3
11 EPWR_9V 44 INPUT4
Rockwell Automation Publication 2094-IN012C-EN-P - August 2013
http://literature.rockwellautomation.com/idc/groups/literature/documents/in/2090-in010_-en-p.pdfhttp://literature.rockwellautomation.com/idc/groups/literature/documents/rm/2094-rm001_-en-p.pdf
Kinetix 6200 and Kinetix 6500 Control Modules 9
This is the IOD connector pinout for the safe torque off (-S0) control modules.
2094-SE02F-M00-S0 and 2094-EN02D-M01-S0 Control Modules
Refer to the Kinetix 6200 and Kinetix 6500 Safe Torque-off Safety Reference Manual, publication 2094-RM002, for signal descriptions and more information on safe torque-off safety functions.
IOD Connector Pin Orientation
IOD Pin Signal
IOD Pin Signal
IOD Pin Signal
IOD Pin Signal
0 12
23 SS_IN_CH2
33
1 AUX_SIN+AUX_A+ 13 34
2 AUX_SIN-AUX_A- 14 24VPWR 24 SS_IN_CH3 35
3 AUX_COS+AUX_B+ 15 24VCOM 25 RESET_REF 36
4 AUX_COS-AUX_B- 16 26 RESET_IN 37
5 AUX_DATA+AUX_I+ 17 SPWR 27 TEST_OUT_0 38
6 AUX_DATA-AUX_I- 18 SCOM 28 TEST_OUT_1 39 24VPWR (1)
(1) Signals 24VPWR and 24VCOM (IOD-39 and IOD-40) are a 24V DC source you can use to operate the digital inputs (50 mA maximum per input).
7 AUX_CLK+ 19 SS_IN_CH0 29 40 24VCOM (1)
8 AUX_CLK- 20 SS_IN_CH1 30 41 INPUT1
9 EPWR_5V 21 SS_OUT_CH0 31 42 INPUT2
10 ECOM22 SS_OUT_CH1 32
43 INPUT3
11 EPWR_9V 44 INPUT4
44-pin Control ModuleI/O, Safety, and Auxiliary
Feedback (IOD) Connector
Pin 30
Pin 44
Pin 1
Pin 15
Pin 16
Pin 31
Rockwell Automation Publication 2094-IN012C-EN-P - August 2013
http://literature.rockwellautomation.com/idc/groups/literature/documents/rm/2094-rm002_-en-p.pdf
10 Kinetix 6200 and Kinetix 6500 Control Modules
Feedback Connector Pinouts
MF Connector Pin Orientation
MF Pin Description Signal
1 Sine differential input +A differential input +MTR_SIN+MTR_A+
2 Sine differential input -A differential input -MTR_SIN-MTR_A-
3 Cosine differential input +B differential input +MTR_COS+MTR_B+
4 Cosine differential input -B differential input -MTR_COS-MTR_B-
5 Data differential input/output +Index differential input +MTR_DATA+MTR_I+
6 Encoder common MTR_ECOM
7 Encoder 9V power output MTR_EPWR9V
8 Hall commutation S3 input MTR_S3
9 Clock output + MTR_CLK+
10 Data differential input/output -Index differential input -MTR_DATA-MTR_I-
11 Motor thermostat (normally closed) (1)
(1) Not applicable unless motor has integrated thermal protection.
MTR_TS+
12 Hall commutation S1 input MTR_S1
13 Hall commutation S2 input MTR_S2
14 Encoder 5V power output MTR_EPWR5V
15 Clock output - MTR_CLK-
IMPORTANT Drive-to-motor power cables must not exceed 90 m (295.5 ft). Additional limitations apply. Refer to the Kinetix 6200 and Kinetix 6500 Modular Servo Drive User Manual, publication 2094-UM002, for more information.
Pin 11Pin 6
Pin 15
Pin 1
Pin 10Pin 5 15-pin Control Module
Motor Feedback (MF) Connector
Rockwell Automation Publication 2094-IN012C-EN-P - August 2013
http://literature.rockwellautomation.com/idc/groups/literature/documents/um/2094-um002_-en-p.pdf
Kinetix 6200 and Kinetix 6500 Control Modules 11
Motor Overload Protection
This servo drive uses solid-state motor overload protection that operates in accordance with UL 508C. Motor overload protection is provided by algorithms (thermal memory) that predict actual motor temperature based on operating conditions as long as control power is continuously applied. However, when control power is removed, thermal memory is not retained.
In addition to thermal memory protection, this drive provides an input for an external temperature sensor/thermistor device, embedded in the motor, to support the UL requirement for motor overload protection.
Some motors supported by this drive do not contain temperature sensors/thermistors; therefore, motor overload protection against excessive consecutive motor overloads with power cycling is not supported.
This servo drive meets the following UL 508C requirements for solid-state overload protection.
Refer to your servo drive user manual for the interconnect diagram that illustrates the wiring between your motor and drive.
Motor Overload Protection Trip Point Value
Ultimately 100% overload
Within 8 minutes 200% overload
Within 20 seconds 600% overload
ATTENTION: To avoid damage to your motor due to overheating caused by excessive, successive motor overload trips, follow the wiring diagram provided in the user manual for your motor and drive combination.
Rockwell Automation Publication 2094-IN012C-EN-P - August 2013
Additional ResourcesThese documents contain additional information concerning related products from Rockwell Automation.
You can view or download publications at http://literature.rockwellautomation.com. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative.
Resource Description
Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drive User Manual, publication 2094-UM002
Provides information on installing, configuring, startup, troubleshooting, and applications for your Kinetix 6200 and Kinetix 6500 servo drive systems.
Kinetix 6000M Integrated Drive-Motor System User Manual, publication 2094-UM003
Provides information on installing, configuring, startup, troubleshooting, and applications for your Kinetix 6000M integrated drive-motor (IDM) system.
Kinetix 6000 Power Rail Installation Instructions, publication 2094-IN003
Provides information on the installation of your Bulletin 2094 Power Rail.
Fiber-optic Cable Installation and Handling Instructions, publication 2090-IN010
Provides information on proper handling, installing, testing, and troubleshooting fiber-optic cables.
System Design for Control of Electrical Noise Reference Manual, publication GMC-RM001 Provides information, examples, and techniques designed to
minimize system failures caused by electrical noise.EMC Noise Management DVD, publication GMC-SP001
Kinetix 6200 and Kinetix 6500 Safe Speed Monitoring Safety Reference Manual, publication 2094-RM001 Provides information on wiring, configuring, and
troubleshooting the safety functions of your Kinetix 6200 and Kinetix 6500 drives.Kinetix 6200 and Kinetix 6500 Safe Torque-off Safety Reference
Manual, publication 2094-RM002
Kinetix Motion Control Selection Guide, publication GMC-SG001 Specifications, motor/servo-drive system combinations, and accessories for Kinetix motion control products.
Kinetix Servo Drives Specifications, publication GMC-TD003Provides product specifications for Kinetix Integrated Motion over EtherNet/IP, Integrated Motion over sercos interface, EtherNet/IP networking, and component servo drive families.
Rockwell Automation Product Certification, website http://rockwellautomation.com/products/certification
For declarations of conformity (DoC) currently available from Rockwell Automation.
Rockwell Automation Industrial Automation Glossary, publication AG-7.1 A glossary of industrial automation terms and abbreviations.
Publication 2094-IN012C-EN-P - August 2013 PN-215234Supersedes Publication 2094-IN012B-EN-P - October 2009 Copyright 2013 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
Allen-Bradley, CompactLogix, ControlLogix, Guardmaster, Kinetix, Logix5000, PowerFlex, Rockwell Software, Rockwell Automation, and SoftLogix are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Rockwell Otomasyon Ticaret A.., Kar Plaza Merkezi E Blok Kat:6 34752 erenky, stanbul, Tel: +90 (216) 5698400
http://literature.rockwellautomation.com/idc/groups/literature/documents/um/2094-um002_-en-p.pdfhttp://literature.rockwellautomation.com/idc/groups/literature/documents/in/2094-in003_-en-p.pdfhttp://literature.rockwellautomation.com/idc/groups/literature/documents/in/2090-in010_-en-p.pdfhttp://literature.rockwellautomation.com/idc/groups/literature/documents/rm/gmc-rm001_-en-p.pdfhttp://literature.rockwellautomation.com/idc/groups/literature/documents/rm/2094-rm001_-en-p.pdfhttp://literature.rockwellautomation.com/idc/groups/literature/documents/rm/2094-rm002_-en-p.pdfhttp://literature.rockwellautomation.com/idc/groups/literature/documents/sg/gmc-sg001_-en-p.pdfhttp://rockwellautomation.com/products/certificationhttp://literature.rockwellautomation.comhttp://literature.rockwellautomation.com/idc/groups/literature/documents/um/2094-um003_-en-p.pdfhttp://literature.rockwellautomation.com/idc/groups/literature/documents/qr/ag-qr071_-en-p.pdfhttp://literature.rockwellautomation.com/idc/groups/literature/documents/td/gmc-td003_-en-p.pdf
Front CoverAbout the Control ModulesCatalog Number ExplanationBefore You BeginModule Compatibility
Install the Control ModulesConnector DataIOD Connector PinoutsFeedback Connector Pinouts
Motor Overload ProtectionAdditional ResourcesBack Cover
Introduction_Category Types
This tab summarizes Rockwell Automation Global Sales and Marketing preferred printing standards. It also provides guidance on whether a publication should be released as JIT (print on demand) or if it requires an RFQ for offset printing.Find your publication type in the first section below. Use the assigned Printing Category information to determine the standard print specifications for that document type. The Printing Categories are defined below the Publication Type section. Note there may be slightly different print specifications for the categories, depending on the region (EMEA or Americas).For more information on Global Sales and Marketing Printing Standards, see publication RA-CO004 in DocMan.
Publication Type and Print Category
Publication TypeOff Set Print Category Spec. (See table below)JIT Spec. (See table below)DescriptionOrder Min **Order Max **Life Cycle Usage / Release Option
ADNA - PuttmanNAAdvertisement Reprint ColourNANAPresale / Internal
APA3D2Application Solution or Customer Success Story5100Presale / External
ARNANAArticle/Editorial/BylineNANAPresale / Internal
(press releases should not be checked into DocMan or printed)
ATB3, B4D5Application techniques5100Presale / External
BRA2 Primary, A1NABrochures5100Presale / External
CAC2 Primary, C1NACatalogue150Presale / External
CGNANACatalogue Guide150Presale / External
CLNANACollection550Presale / External
COA5, A6, A9D5Company Confidential InformationNANANA / Confidential
CPE-onlyE-only, D5Competitive Information550NA / Confidential
DCE-onlyE-onlyDiscount SchedulesNANAPresale / Internal
DIA1, A3NADirect Mail5100Presale / Internal
DMNANAProduct Demo550Presale / Internal
DSB3D5Dimensions Sheet15Post / External
DUB3D5Document Update15Post / External
GRB2D6Getting Results15Post / External
INB3 Primary, B2D5, D6Installation instructions15Post / External
LMNANALaunch Materials550Presale / Internal
PCB3D5Packaging Contents
PLE-only primary, B3E-onlyPrice List550Presale / Internal
PMB2D6Programming Manual15Post / External
PPA3D1Profile (Single Product or Service). NOTE: Application Solutions are to be assigned the AP pub type.5100Presale / External
QRB2 primary, B3, B5D5, D6Quick Reference15Post / External
QSB2 primary, B3, B5D5, D6Quick Start15Post / External
RMB2D5, D6Reference Manual15Post / External
RNB3D5Release Notes15Post / External
SGB1 Primary, B4D5, D6Selection Guide Colour550Presale / External
SGB2D5, D6Selection Guide B/W550Presale / External
SPA1, A2, A3, A4NASales Promotion NOTE: Service profiles are to be assigned the PP pub type.5100Presale / Internal
SRB2, B3D5, D6Specification Rating Sheet5100Presale / External
TDB2 Primary B3, B4, B5D5, D6Technical Data550Presale / External
TGB2, B3D6Troubleshooting Guide15Post / External
UMB2 Primary, B4D6User Manual B/W15Post / External
WDB3D5Wiring Diagrams / Dwgs15Post / Internal
WPB3 Primary, B5D5White Paper550Presale / External
** Minimum order quantities on all JIT items are based on the publication length. **
Publication lengthMinimum Order Quantity
77 or more pages1 (no shrink wrap required)
33 to 76 pages25
3 to 32 pages50
1 or 2 pages100
Pre-sale / MarketingAll paper in this category is White Brightness, 90% or better. Opacity 90% or better
CategoryColor OptionsAP, EMEA Paper RequirementsCanada, LA, US Paper Requirements
A14 color170 gsm 2pp100# gloss cover, 100# gloss text
A24 color170 gsm , folded, 4pp100# gloss cover, 80# gloss text
A34 colorCover 170 gsm with Body 120 gsm, > 4pp80# gloss cover, 80# gloss text
A42 color170gsm Silk 120gsm Silk80# gloss cover, 80# gloss text
A52 color170gsm Silk 120gsm Silk80# gloss cover, 80# matt sheet text
A61 color170gsm Silk 120gsm Silk80# gloss cover, 80# matt sheet text
A74 color cover2 color textSelection GuideCategory being deleted10 Point Cover C2S50# matte sheet text
A84 color coverCategory being deleted50# matte sheet text, self cover
2 color text
Selection Guide
A92 color100gsm bond50# matte sheet text, self cover
Selection Guide
Gray shading indicates Obsolete Print Catagories
Post Sale / Technical Communication
CategoryColor OptionsAP, EMEA Paper RequirementsCanada, LA, US Paper Requirements
B14 color cover270gsm Gloss 100gsm bond10 Point Cover C2S
2 color text50# matte sheet text
B21 color160gsm Colortech & 100gsm Bond90# Cover50# matte sheet text
B31 color100gsm bond50# matte sheet text, self cover
B42 color160gsm Colortech & 100gsm Bond90# Cover50# matte sheet text
B52 color100gsm bond50# matte sheet text, self cover
Catalogs
CategoryColor OptionsAP, EMEA Paper RequirementsCanada, LA, US Paper Requirements
C14 color cover270gsm Gloss 90gsm silk10 Point Cover C2S
4 color text45# Coated Sheet
C24 color cover270gsm Gloss 80gsm silk10 Point Cover C2S
2 color text32#-33# Coated Sheet
JIT / PODAll paper in this category is White Brightness, 82% or better. Opacity 88% or better
CategoryColor OptionsAP, EMEA Paper RequirementsCanada, LA, US Paper Requirements
D14 color170gsm white silk80# gloss cover, coated 2 sides
D24 color120gsm white silk80# gloss text, coated 2 sides, self cover
D34 colorCover 170gsm with Body 120gsm80# gloss cover, 80# gloss text coated 2 sides
D41 color160gsm tab90# index
D51 color80gsm bond20# bond, self cover
D61 colorCover 160gsm tab with Body 80gsm bond90# index, 20# bond
D72 color160gsm tab90# index
D82 color80gsm bond20# bond, self cover
D92 colorCover 160gsm tab with Body 80gsm bond90# index, 20# bond
D10Combination: 4 color cover, with 2 color bodyCover 160gsm with Body 80gsm90# index, 20# bond
Gray shading indicates Obsolete Print Catagories
Just In Time (JIT) or Off Set (OS)?
Use these guidelines to determine if your publication should be JIT (just in time/print on demand) or if it would be more economical to print OS (offset/on a press). OS print jobs require an RFQ (Request For Quote) in US. If your job fits into the Either category, an RFQ is recommended, but not required. In the US, RA Strategic Sourcing will discourage or reject RFQs for jobs that fall within the JIT category. Guidelines differ for black & white and color printing, so be sure to check the correct tables.
Black & White Printing
Color Printing
Color Printing
Print Spec Sheet
JIT Printing SpecificationsRA-QR005J-EN-P - 6/14/2013
Printing SpecificationYOUR DATA HEREInstructionsNO
(required) Publication Number:2094-IN012C-EN-PSample: 2030-SP001B-EN-P11 x 17LOOSE -Loose LeafYESPre-sale / MarketingTOP
Use Legacy Number:NOYES or NO8.5 x 11PERFECT - Perfect BoundA1LEFT
Legacy Number if applicable:Sample Legacy Number: 0160-5.338.375 x 10.875SADDLE - Saddle StitchA2RIGHTCORNER
Publication Title:Kinetix 6200 and Kinetix 6500 Control Module Installation InstructionsSample: ElectroGuard Selling Brief80 character limit - must match DocMan Title8.25 x 11 (RA product profile std)PLASTCOIL - Plastic Coil (Coil Bound)A4BOTTOMSIDE
Used in Manufacturing:YESYES or NO - If Yes, must have Part No. listed below8.25 x 10.875STAPLED1 -1 positionA3
Part Number:PN-215234If SAP Part Number, be sure to enter PN- before the number7.385 x 9 (RSI Std)STAPLED1B - bottom 1 positionA5
(required) CategoryD5Select Print Category A,B,C or D from category list, on "Introduction_Category Types" tab6 x 4STAPLED2 - 2 positionsA6
Paper Stock Color:White is assumed. For color options contact your vendor5.5 x 8.5 (half-size)THERMAL - Thermal bound (Tape bound)A7
Ink Color:One color assumes BLACK / 4 color assume CMYK / Indicate PMS number here4.75 x 7.75THERMALO - Thermal Bound (Tape bound - offline)A8
Page Count:12Total page count including cover. Enter PAGE count, not SHEET count4.75 x 7 (slightly smaller half-size)A9
(required) Finished Trim Size Width:5.5 x 8.5 (half-size)This is sheet size, before folding4.25" x 5.50"Post Sale / Technical Communication
Fold:Half or V or Single FoldReview key below. Leave blank if folded for saddle stitching4 x 6B1
Finished Fold Size:2.75x8.5This is size after folding is completed3 x 5B2
Binding/Stitching:SADDLE - Saddle StitchReview key below9 x 12 (Folder)B3None
Stitching Location:SIDEBlank, Corner or SideA4 (8 x 11 ) (210 x 297 mm)B4Half or V or Single Fold
Drill Hole (Yes/No):NOAll drilled publications use the 5-hole standard, 5/16 inch-size hole and a minimum of inch from the inner page border.A5 (5.83 x 8.26) (148 x 210 mm)B5C or Tri-Fold
Number of Tabs Needed:5 tab in stock at RR Donnelley36 x 24 PosterCatalogsDbleParll
Number of Pages per Pad:Average sheets of paper. 25, 50 75,100 Max24 x 36 PosterC1Sample
Glue Location on Pad:Glue location on pads18 x 24 PosterC2Short (must specify dimensions between folds in Comments)
(required) Business Group:Marketing CommercialAs entered in DocManJIT/PODZ or Accordian Fold
(required) Cost Center:19134 - IAIf your Business Unit is Marketing Commercial, add the appropriate division name after 19134 using the chart on the right. All other Business Units: Enter only the number as in DocMan, no description. Example - 1902119134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C19134 - Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134 - Safety 19134 - Industr 19134 - Softwar19134 - Mkt Dig 19134 - US MarkeD1Microfold or French Fold - designate no. of folds in Comments - intended for single sheet only to be put in box for manufacturing
Comments:Fold to 2.75x8.5 with PN-215234 on the back cover facing up. Eonly for global distribution. POD/JIT for manufacturing.D2Double Gate
FoldsHalf, V, Single C or Tri
Dble Parll
Z or Accordian Microfold or French
Double Gate
Short FoldSaddle-Stitch Items All page quantities must be divisible by 4.Note: Stitching is implied for Saddle-Stitch -no need to specify in Stitching Location.80 pgs max. on 20# (text and cover)76 pgs max. on 20# (text) and 24# (cover)72 pgs max. on 24# (text and cover)
Perfect Bound Items940 pgs max. w/cover (90# index unless indicated otherwise)70 pgs. min. for spine without words200 pgs min. for spine with words
Plastcoil Bound Items530 pgs max. of 20# (if adding cover deduct equivalent number of pages to equal cover thickness) (90# index unless indicated otherwise)
Tape Bound Items250 pgs max. on 20# no cover240 pgs max. w/cover (90# index unless indicated otherwise)D3
D4
D5
D6
D7
D8
D9
MBD000B0209.bin
MBD000B020B.bin
MBD000B020C.bin
MBD000B020A.bin
MBD000B0205.bin
MBD000B0207.bin
MBD000B0208.bin
MBD000B0206.bin
MBD000B0203.bin
MBD000B0204.bin
/ColorImageDict > /JPEG2000ColorACSImageDict > /JPEG2000ColorImageDict > /AntiAliasGrayImages false /CropGrayImages true /GrayImageMinResolution 300 /GrayImageMinResolutionPolicy /OK /DownsampleGrayImages true /GrayImageDownsampleType /Average /GrayImageResolution 300 /GrayImageDepth 8 /GrayImageMinDownsampleDepth 2 /GrayImageDownsampleThreshold 2.00000 /EncodeGrayImages true /GrayImageFilter /FlateEncode /AutoFilterGrayImages false /GrayImageAutoFilterStrategy /JPEG /GrayACSImageDict > /GrayImageDict > /JPEG2000GrayACSImageDict > /JPEG2000GrayImageDict > /AntiAliasMonoImages false /CropMonoImages true /MonoImageMinResolution 1200 /MonoImageMinResolutionPolicy /OK /DownsampleMonoImages true /MonoImageDownsampleType /Average /MonoImageResolution 1200 /MonoImageDepth -1 /MonoImageDownsampleThreshold 1.50000 /EncodeMonoImages true /MonoImageFilter /CCITTFaxEncode /MonoImageDict > /AllowPSXObjects false /CheckCompliance [ /None ] /PDFX1aCheck false /PDFX3Check false /PDFXCompliantPDFOnly false /PDFXNoTrimBoxError true /PDFXTrimBoxToMediaBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXSetBleedBoxToMediaBox true /PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXOutputIntentProfile (None) /PDFXOutputConditionIdentifier () /PDFXOutputCondition () /PDFXRegistryName () /PDFXTrapped /False
/CreateJDFFile false /Description > /Namespace [ (Adobe) (Common) (1.0) ] /OtherNamespaces [ > /FormElements false /GenerateStructure true /IncludeBookmarks false /IncludeHyperlinks false /IncludeInteractive false /IncludeLayers false /IncludeProfiles true /MultimediaHandling /UseObjectSettings /Namespace [ (Adobe) (CreativeSuite) (2.0) ] /PDFXOutputIntentProfileSelector /NA /PreserveEditing true /UntaggedCMYKHandling /LeaveUntagged /UntaggedRGBHandling /LeaveUntagged /UseDocumentBleed false >> ]>> setdistillerparams> setpagedevice
top related