Transcript
1 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007
Core Network Planning WorkshopDX200 Platform
2 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use
Contents
Nokia MSCi, TMSCi, HLRi and SRRi (DX 200 platform)
• HW overview (cabinets, cartridges, functional units, PIU, MB etc)
• Interfaces
• Capacities and roadmap
Nokia MSCi
Nokia Transit MSCi
Nokia Compact MSCi
Nokia HLR
3 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use
Cartridge Construction Products - i-series
DX 200 MSCi
DX 200 Transit MSCi
DX 200 Compact MSCi
DX 200 HLRi
4 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use
Network Structure
NMS
SMSC
NETWORK SUBSYSTEMNETWORK SUBSYSTEM
MSCi
SMSC
VMS
Compact MSCiPBX
VMS
Transit MSCi
HLRi
ININ
BSS BSS
PBXPBX
PSTN/ISDN
PSTN/ISDN
5 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use
Cabinets
Height: 2 m, width: 90 cm, depth: 60 cm, according to ETSI standard
Internal cabling is always the same
Strappings done with pre-wired connectors
All delivered cabinets are pre-wired and equipped with all necessary cartridges and cables
Shorter installation time on site
Considerably fewer parts to be mounted
6 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use
Cabinet Types
MOMC - Main Operation and Maintenance Cabinet for MSCi
VLRC - Visitor Location Register Cabinet for MSCi
ETC - Exchange Terminal Cabinet for MSCi
GSWC - Group Switch Cabinet for MSCi
IWC - InterWorking Cabinet for MSCi
GSC - General Signalling Cabinet for Transit MSCi
MMAC - Compact MSCi Cabinet A
MMBC - Compact MSCi Cabinet B
HLRC - Home Location Register Cabinet
HLGC - Home Location Group Switch Cabinet
7 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use
Cabinet Parts
POWER SUPPLYCONNECTOR GROUP
FILTER
FUSE UNIT(PDFU)
DOOR RIGHT
RAIL FORSHELVES
CARTRIDGESHELF
COVER FOR WHEEL BOXADJUSTABLE FEET WHEEL
HORIZONTALGROUNDINGBAR
DOOR LEFT
CARTRIDGE
SIDE COVERPLATE - SCPOR EMC GASKETFRAME
VERTICALGROUNDING
BAR
COVER FORPOWER SUPPLY
CABLESUPPORT
8 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use
Cartridges
M4 x 10
9 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use
DX 200 MSCi Capacity (M13)
• Extendable from 100,000 subscribers (7 cabinets + 4 cabling cabinets) to 1,000,000 subscribers (15 cabinets + 8 cabling cabinets)
• BHCA capacity from 100.000 to 1,000,000
• 1,500,000 SMS/BH
• 688 PCMs with ECU
• 2048 GSW
• 1,000,000 subscribers• 200,000 Tel. subs• 1,000,000 BHCA• 1,500,000 BHSM• 16,700 Erlangs• 1392 ext. PCMs• 416 C7 links
• 1,000,000 subscribers• 200,000 Tel. subs• 1,000,000 BHCA• 1,500,000 BHSM• 16,700 Erlangs• 1392 ext. PCMs• 416 C7 links
10 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use
DX 200 MSCi
OMU
TGFP
CDSU GSW
BSS
NSS
X.25 or LAN to OMC andSMS
PSTN
VLRUCMCMUCCMU STU CHU
ET
ECET
CLS
PABXECET
ET
VDU andLPT
VDU andLPT
PAUBSUMFSU BDCUM
LANLAN
CASUCCSU
MB
LAN
11 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use
MSCi - Functional unit configurations
maxCCSUCASU 14 (incl. spares)PAUBSU 15 + 1 VLRU pairs 8ET 704ET&ECU 688BDCU 3CHU pairs 3CDSU 42MFSU 5 + 1
12 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use
MSCi Cabinet Layout (max. configuration)- Row 1
SDSTU
SDSTU
STU1
PDFU PDFU
BSU0
BSU1
CLBU
CLBU
xSU1
xSU0
MFSU2
BDCU1
xSU2
BSU2
BSU3
VLRU0-1
VLRU1-0
VLRU0-0
STU0
VLRU1-1
SDCHU
SDCHU
CHU0-1
PDFU PDFU
BSU4
BSU5
xSU4
xSU3
MFSU3
BDCU2
xSU5
BSU6
BSU7
VLRU2-1
VLRU3-0
VLRU2-0
CHU0-0
VLRU3-1
SDCHU
SDCHU
CHU1-1
PDFU PDFU
BSU8
BSU9
CLBU
CLBU
xSU8
xSU7
MFSU4
GSU6
xSU9
BSU10
BSU11
VLRU4-1
VLRU5-0
VLRU4-0
CHU1-0
VLRU5-1
SDCHU
SDCHU
CHU2-1
PDFU PDFU
BSU12
BSU13
xSU12
xSU11
MFSU5
GSU10
xSU13
BSU14
BSU15
VLRU6-1
VLRU7-0
VLRU6-0
CHU2-0
VLRU7-1
0
1
2
3
4
5
6
7
8
9
10
CLBU
CLBU
CLBU
CLBU
OMU0
OMU1
PDFU PDFU
CCMU1
M0
M1
CCMU0 C
LSU
CM0
SDOMU
CM1
SDOMU
CMU0
CMU1
MFSU1
BDCU0
MFSU0
MOMC VLRC VLRC VLRC VLRC
NOTE: xSU = CCSU/CASU/PAU as needed
13 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use
MSCi Cabinet Layout (max. configuration) - Row 2
PDFU PDFU
GSW0-0
GSW0-1
GSW0-2
GSW0-3
PDFU PDFU
GSW1-0
GSW1-1
GSW1-2
GSW1-3
0
1
2
3
4
5
6
7
8
9
10
PDFU PDFU
ECET
ECET ECET
ECET ECETEC
EC EC
CLBU
0
1
2
3
4
5
6
7
8
9
10
PDFU PDFU
CLBU
0
1
2
3
4
5
6
7
8
9
10CDSU
PDFU PDFU
CDSUCDSU
CLBU
CDSU CDSUCDSU
CDSU CDSUCDSU
CDSU CDSUCDSU
CDSUCDSU ECET
ECET ECET
ECET ECETEC
EC EC
0
1
2
3
4
5
6
7
8
9
10
GSWC GSWC ETC IWC ETC
14 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use
MSCi Cabinet Layout (max. configuration) - Row 3
CDSU
PDFU PDFU
CDSUCDSU
CLBU
CDSU CDSUCDSU
CDSU CDSUCDSU
CDSU CDSUCDSU
CDSUCDSU
0
1
2
3
4
5
6
7
8
9
10CDSU
PDFU PDFU
CDSUCDSU
CLBU
CDSU CDSUCDSU
CDSU CDSUCDSU
CDSU CDSUCDSU
CDSUCDSU
0
1
2
3
4
5
6
7
8
9
10
0
1
2
3
4
5
6
7
8
9
10
PDFU PDFU
CLBU
ECET
ECET ECET
ECET ECETEC
EC EC
PDFU PDFU
CLBU
ECET
ECET ECET
ECET ECETEC
EC EC
PDFU PDFU
CLBU
ECET
ECET ECET
ECET ECETEC
EC EC
ETCETC IWC ETC IWC ETC
15 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use
DX 200 Transit MSCi (M13) Capacity
• 1.400.000 BHCA• 20.000 Erlangs • 1024 C7 links• 1648 ext. PCMs• 784 PCMs with ECU
• 1.400.000 BHCA• 20.000 Erlangs • 1024 C7 links• 1648 ext. PCMs• 784 PCMs with ECU
• Extendable from 600,000 BHCA to 1,400,000 BHCA
• 2048 GSW
16 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use
DX 200 Transit MSCi
OMU
TGFP
GSW
MSC
NSS
X.25 or LAN to OMC andSMS
PSTN
CMCMUCCMU STU CHU
ET
ECET
CLS
PABXECET
ET
VDU andLPT
VDU andLPT
CASUMFSU BDCU
MB
M
LAN
PAUCCSU
LAN
17 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use
Transit MSCi - Functional unit configurations
maxCCSUCASU 33 (incl. spares)PAUET 864ET&ECU 784BDCU 5CHU pairs 3MFSU 4 + 1
18 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use
Transit MSCi Cabinet Layout (max. configuration)row 1
NOTE: xSU = CCSU/CASU/PAU as needed
OMU0
OMU1
PDFU PDFU
CCMU1
M0
M1
CCMU0 C
LSU
CM0
SDOMU
CM1
SDOMU
CMU0
CMU1
MFSU1
BDCU0
MFSU0
0
1
2
3
4
5
6
7
8
9
10
SDSTU
SDSTU
STU1
PDFU PDFU
CLBU
CLBU
xSU7
xSU6
MFSU2
BDCU1
xSU8
STU0
xSU0
xSU1
xSU2
xSU4
xSU3
xSU5
SDCHU
SDCHU
CHU0-1
PDFU PDFU
CLBU
CLBUxSU16
xSU15
MFSU3
BDCU2
xSU17
CHU0-0
xSU13
xSU12
xSU14
xSU10
xSU9
xSU11
SDCHU
SDCHU
CHU1-1
PDFU PDFU
CLBU
CLBU
xSU25
xSU24
MFSU4
BDCU3
xSU26
CHU1-0
xSU22
xSU21
xSU23
xSU21
xSU18
xSU20
SDCHU
SDCHU
CHU2-1
PDFU PDFU
CLBU
CLBUBDCU
4
CHU2-0
xSU31
xSU30
xSU32
xSU28
xSU27
xSU29
MOMC GSC GSC GSC GSC
19 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use
Transit MSCi Cabinet Layout (max. configuration)row 2
PDFU PDFU
GSW
GSW
GSW
GSW
PDFU PDFU
GSW
GSW
GSW
GSW
0
1
2
3
4
5
6
7
8
9
10
0
1
2
3
4
5
6
7
8
9
10
0
1
2
3
4
5
6
7
8
9
10
0
1
2
3
4
5
6
7
8
9
10
PDFU PDFU
CLBU
ECET
ECET ECET
ECET ECETEC
EC EC
PDFU PDFU
CLBU
ECET
ECET ECET
ECETECETEC
EC EC
GSWC GSWC ETC ETC
20 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use
Transit MSCi Cabinet Layout (max. configuration)row 3
ETCETCETC
0
1
2
3
4
5
6
7
8
9
10
0
1
2
3
4
5
6
7
8
9
10
PDFU PDFU
CLBU
ECET
ECET ECET
ECET ECETEC
EC EC
PDFU PDFU
CLBU
ECET
ECET ECET
ECET ECETEC
EC EC
0
1
2
3
4
5
6
7
8
9
10
PDFU PDFU
CLBU
ECET
ECET ECET
ECET ECETEC
EC EC
0
1
2
3
4
5
6
7
8
9
10
PDFU PDFU
CLBU
ECET
ECET ECET
ECET ECETEC
EC EC
ETC
21 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use
DX 200 HLRi (M13)
AUC EIR
3,750,000 subscribers 1,250,000 Telemetric Subs1,250,000 Telemetric Subs3,750,000 subscribers 1,250,000 Telemetric Subs1,250,000 Telemetric Subs
• AuC capacity: 7.500.000 subscribers
• EIR capacity: – 10 million entries on black list– 4 million entries on grey list (1...1,000 IMEIs/entry)– 200,000 entries on white list (1...1,000,000 IMEIs/entry)
• 512 C7 links
• 512 GSW
22 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use
DX 200 HLRi
OMU
GSW
X.25 or LAN to OMC andSMS
MSC
STU
ET
CLS
HLRET
VDU andLPT
VDU andLPT
CMMCCSU BDCU
ACU DBDUHLRUEMU
EIRU
MB
LAN
23 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use
HLRi - Functional unit configurations
max
CCSU 32 + 1EIRU 7ACU pairs 5ET 96BDCU 2HLRU pairs 10
24 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use
HLRi (3,750,000 subs) Cabinet Layout
0
1
2
3
4
5
6
7
8
9
10
PDFU PDFUCLBU
ET EIRU
0CCSU4
CCSU6
CCSU7
CCSU8
CCSU5
CLBU
PDFU PDFU
CLBU
ET EIRU
2EIRU1
CCSU10
CCSU11
CCSU12
CCSU9
CLBU
DBDU0-0
SDDBDU
DBDU0-1
ACU0-0
SDACU
ACU0-1
PDFU PDFU
BDCU0
BDCU1
CLSU
SDOMU
SDOMU
GSW1-0
GSW1-1
GSW0-0
GSW0-1
CMM0
CMM1
OMU0
OMU1
CCSU1
CCSU2
CCSU3
CCSU0
SDSTU
STU1
STU0
SDSTU
SDEMU
EMU1
EMU0
SDEMU
SDHLRU
HLRU0-1
HLRU0-0
SDHLRU
SDHLRU
HLRU1-1
HLRU1-0
SDHLRU
PDFU PDFU
CLBU
ET EIRU
3CCSU13
CCSU15
CCSU16
CCSU17
CCSU14
CLBU
ACU1-0
SDACU
ACU1-1
SDHLRU
HLRU2-1
HLRU2-0
SDHLRU
SDHLRU
HLRU3-1
HLRU3-0
SDHLRU
PDFU PDFU
CLBU
ET EIRU
4CCSU18
CCSU20
CCSU21
CCSU22
CCSU19
CLBU
ACU2-0
SDACU
ACU2-1
SDHLRU
HLRU4-1
HLRU4-0
SDHLRU
SDHLRU
HLRU5-1
HLRU5-0
SDHLRU
PDFU PDFU
CLBU
ET EIRU
5CCSU23
CCSU25
CCSU25
CCSU27
CCSU24
CLBU
ACU3-0
SDACU
ACU3-1
SDHLRU
HLRU6-1
HLRU6-0
SDHLRU
SDHLRU
HLRU7-1
HLRU7-0
SDHLRU
PDFU PDFU
CLBU
ET EIRU
6CCSU28
CCSU30
CCSU31
CCSU32
CCSU29
CLBU
ACU4-0
SDACU
ACU4-1
SDHLRU
HLRU8-1
HLRU8-0
SDHLRU
SDHLRU
HLRU9-1
HLRU9-0
SDHLRU
HLRC HLRC HLRC HLRCHLRCHLRCHLGC
41 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007
top related