YOU ARE DOWNLOADING DOCUMENT

Please tick the box to continue:

Transcript
Page 1: SOCOMEC METER SELECTION CHART

IPD INDUSTRIAL PRODUCTS Phone: 1300 556 601 Fax: 1300 550 187 www.ipdgroup.com.au

SOCOMEC METER SELECTION CHART

*Modbus communication *Memory fitted as standard *Ethernet communication *Modbus communication *2 analogue output *Ethernet communications (0-20mA, 4-20mA or 0-10VDC) *2 analogue output *Temperature input (0-20mA, 4-20mA or 0-10VDC) *Memory (loadcurve) *Temperature input *Pulse output *Pulse output

Refer to IPD for a selection of accessories(CT’s, CT terminal blocks and add-on modules)

Current Transformers (CT)

Refer to IPD for a selection of accessories(CT’s, CT terminal blocks and add-on modules)

CT shorting linksFuse holders and links

RS485Modbus

RTU

RS485Modbus

RTU

RS485Modbus

RTU

RS485Modbus

RTU

RS485Modbus

RTU

RS485Modbus

RTU

RS485Modbus

RTU

RS485Modbus

RTU

RS485Modbus

RTU

RS485Modbus

RTU

RS485Modbus

RTU

COUNTIS Range - kWh meters

COUNTIS Range - kWh meters DIRIS / MULTIS Range - Multi-function meters

RS485Modbus

RTU

Three-Phase Three-Phase Three-Phase Three-Phase Three-Phase Three-Phase Three-Phase Three-Phase CT Connect CT Connect CT Connect CT Connect CT Connect CT Connect CT Connect CT Connect E40 E43 L40 A10 A17 A20 A40 A60 P/N: 48503008 P/N: 48503017 P/N: 192J9110 P/N: 48250011 P/N: 48250103 P/N: 48250200 P/N: 48250201 P/N: 48250207

LCD Display • • LED Display • • • • • Single Phase • • • • • • Three Phase • • • • • • • • Active energy kWh • • • • • • • • Reactive energy kvarh • • • • • • • • Partial active energy kWh • • Energy pulse output • • • • • (module required) • (module required) • (module required) RS485 Modbus RTU • • • • • (module required) • (module required) • (module required) Alarm outputs • • • (module required) • (module required) • (module required) Accuracy Class Class 1 Class 1 Class 1 Class 0.5S Class 1 Class 0.5S Class 0.5S Class 0.5S Current transformer connect CT …/5 A CT …/5 A CT …/1A or …/5A CT …/5 A CT …/1A or …/5A CT …/5 A CT …/1A or …/5A CT …/1A or …/5A DIN rail mount (Number of modules) 4 4 4 Panel mount (size) • (96 x 96) • (72 x 72) • (96 x 96) • (96 x 96) • (96 x 96) Total harmonic distortion • • • • • Loadcurve Memory • • (module required) • Self power supplied from measurement • • Plug-in modules

Single-Phase Single-Phase Single-Phase Single-Phase Three-Phase Three-Phase Three-Phase Three-Phase 3 x Single-Phase Direct Connect Direct Connect Direct Connect Direct Connect Direct Connect Direct Connect Direct Connect Direct Connect or 1 x Three-Phase up to 32A up to 32A up to 63A up to 80A up to 63A up to 63A up to 100A up to 100A Direct Connect up to 100A E00 E03 E10 E13 E20 E23 E30 E33 E63 P/N: 48503019 P/N: 48503029 P/N: 48503000 P/N: 48503031 P/N: 48503003 P/N: 48503035 P/N: 48503005 P/N: 48503012 P/N: 48503016

LCD Display • • • • • • • • • Single Phase • • • • • • • Three Phase • • • • • Active energy kWh • • • • • • • • • Reactive energy kvarh • • (via RS485) • (via RS485) Partial active energy kWh • • • • • • Energy pulse output • • • • RS485 Modbus RTU • • • • • Accuracy Class Class 1 Class 1 Class 1 Class 1 Class 1 Class 1 Class 1 Class 1 Class 1 Direct Connect (Amps) 32A 32A 63A 80A 63A 63A 100A 100A 100A DIN rail mount (Number of modules) 1 1 3 3 4 4 7 7 7 Loadcurve Memory • • Self power supplied from measurement • • • • • • • • •

72 x 72mm

*Digital output (pulse output or alarm) *Modbus communication

A2.indd 1 30/10/2014 15:39:10