Project Catalog # Type
Prepared by Notes Date
PS503117EN page 1December 2019
Top Product Features Low-voltage control for ON/OFF and dimming loads Personalize the scene buttons with ON/OFF and dimming needs per output Pre-terminated control cable ready with RJ45 ports eliminate wiring errors
Custom engraving options available - buttons may be replaced in the field (10 character limit)
Interactive Menu• Order Information page 2
• Additional Resources page 3
• Wiring Diagrams page 3
• Product Warranty
Dimensional and Mounting Details Scale or Mounting Height
additionalproduct diagrams
GreengateScene Wallstation
Scene wallstations are pre-engraved low-voltage switches
48” / 1210mm
58” / 1470mm
All On
Scene 1
Scene 2
Scene 3
Scene 4
Pre-engraved buttonssimplify delivery
Color match screwlesswallplates included
RC-6TSB-P4
Programmablebuttons using
Personal Remote
All Off
3.25"[83mm]
1.4"[36mm]
2.8"[72mm]
1.8"[47mm]
4.75"[121mm]
Product Features
Scene Wallstation
PS503117EN page 2December 2019
Order InformationSAMPLE ORDER NUMBER: RC-6TSB-P1-WOne single gang color matching wallplate is included in the package. Standard button engraving shown below. Engraving appears as black text on white, ivory, and gray buttons. Engraving appears as gold text on black buttons. If white engraved text is desired on black buttons use the configurator tool with the FlashPro software.
Catalog Number Number of Buttons Button Engraving Insert Color
Catalog Number Number of Buttons Button Engraving Insert Color
RC-6TSB-P1-W 3=Large Buttons – TLB6= Small Buttons – TSB
P1 = Scene 1, Scene 2, All Off (3TLB) P2 = Scene 1, Scene 2, Scene 3, Scene 4, Scene 5, All Off (6TSB) P3 = All On, Scene 1, Scene 2, Scene 3, Scene 4, All Off (6TSB) P4 = Scene 1, Scene 2, Scene 3, Raise, Lower, All Off (6TSB)
W= WhiteB= BlackV= IvoryG= Gray
NotesFor custom configurations or custom engraving, use the configurator tool within the FlashPro tool.
Additional Information
Catalog Number Description
Catalog Number Description
HHPR-RCLVHH-02
Room Controller Personal RemoteDLVP Personal Remote
Engraving Relay Style Zone / Dimmer 1 Zone / Dimmer 2 Zone / Dimmer 3 Address
All relays ON N/A N/A N/A N/A
Scene 1: All relays ON =50% =50% =50% 12
Scene 2: All relays ON =100% =100% =100% 13
Scene 3: All relays ON =50% =100% =50% 14
Scene 4: All relays ON =30% =0% =25% 15
Scene 5: All relays ON =20% =20% =20% 4
Scene 6: All relays ON =100% =100% =100% DIP #4
All relays OFF N/A N/A N/A N/A
Notes
* Button defaults when shipped.
** Not available in a wallstation configuration
Product SpecificationsMechanicalSize: 4.75” H x 3.25” W (121mm x 83mm)Environment:
• Operating temperature: 32°F to 104°F (0°C to 40°C)• Relative humidity operating: Less than 95%, non-condensing• For indoor use only
Connection Ports: Two RJ45 portsButton Configurations: • Large buttons: 2 or 3 • Small buttons: 2, 4, 5, 6Installation: • Standard decorator opening
ElectricalInput Requirements:
• Class 2, LPSVoltage: 24 VDC supplied from Room Controller
Standards • UL 508 Listed
WarrantyFive year warranty standard
Greengate
Scene Wallstation
PS503117EN page 3December 2019
OverviewThe scene wallstations are pre-engraved low-voltage switches that operate on 24 VDC power supplied by the Room Controller or DLVP power module. Each scene wallstation is designed to fit in a standard decorator opening and has two RJ45 ports for local network connections to eliminate wiring errors.The scene wallstations are pre-terminated control cable ready and work immediately upon power up. Scene wallstations are fully functional out-of-the-box but can be customized to meet needs using a personal remote to adjust and save the scene settings.
InstallationLow-voltage devices are connected using pre-terminated control cables (ordered separately).
Sample Wallstations
RC-3TLB-P1-*Preset Wallstation
Scene 1
Scene 2
All Off
RC-6TSB-P2-*Preset Wallstation
Scene 5
Scene 3
Scene 4
Scene 2
Scene 1
All Off
RC-6TSB-P3-*Preset Wallstation
RC-6TSB-P4-*Preset Wallstation
Scene 4
Scene 2
Scene 3
Scene 1
All On
All Off
Lower
Scene 3
Raise
Scene 2
Scene 1
All Off
Wiring DiagramsRoom Controller Personal Remote DLVP Personal Remote
Zone Raise/
Lower
SETSaves current light levels to selected
Scene
Programmable Scene Buttons
Dimmer 1, 2, 3 Raise/Lower
Relay 1, 2, 3 ON/OFF
Scenes 1-6 Preset� S1 = Button Address 12� S2 = Button Address 13� S3 = Button Address 14� S4 = Button Address 15� S5 = Button Address 4� S6 = Auto On Scene (DIP #4 UP)
SETSaves Current light levels and relay
states to selected Scene
AUXOpen/Close Solatube/Shade Output
Room ControllerPersonal Remote
HHPR-RC
Zone Control
R1 R2 R3
SET AUXOpen/CloseShade or Solatube
S1 S2 S3
S4 S5 S6
To save scene pressSET and select Scene
Greengate
Scene Wallstation
PS503117EN page 4December 2019
Cooper Lighting Solutions1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800www.cooperlighting.com
© 2020 Cooper Lighting Solutions All Rights Reserved.
Specifications and dimensions subject to change without notice.
Control Systems• Greengate
Sample Room Controller System Topology
Dual TechnologyWall/CornerOccupancy/Vacancy Sensor
20A Receptacle Control
RC-6TSB-TS7-*Teacher Station
Row 3
Lower
Raise
All Off
Row 1
Row 2
RC-2TLB-EC1-*
Entry
All Off
Adjustable daylight sensor dome
Daylight sensor
Ceiling
OCC-RJ45
Wal
l
Egress OutputOCC-RJ45
Up to 6 Lighting Zones(3 Relays and 3 Dimmers)
(or additional lighting zone)
(BMS integration)
Room Controller
�
Output for Egress LightingControl, BMS output orReceptable Control
BMS OutputOCC-RJ45
DS-FMOIR
RC3DE
OAWC-DT-120W
SPRC-R-20-120 Entry Station
Sample DLVP System Topology
Model: OCC-RJ45
Occupancy Sensor Coupler
Brown
Black
Red
Blue
All Off
Entry Lighting
General
Whiteboard
Quiet Time
Lower
Raise
A/V Mode
STA
TU
S
TE
ST
RE
SE
T
DEMAND+ -
CLOCK+ -
1
DEMANDRESPONSE
2 2
WALLSENSORS
SWITCHPACK
14 5 6
1 2
LOW VOLTAGE OUTPUTS
LOW HIGH TR
IM
3
RECBMS/OUT
ALERT+ -
Occ
/ Va
c
1
Part
ial O
nPa
rtia
l Off
Zo
ne
/ Are
a
2 3 4 5
10%
1
20%30%40%
2 3 4 5-
--
-
++
+
LL053001EN
V Y Y AO N N Z
+
Low-Voltage Light Fixtures
Low-Voltage Lighting Cables
Receptacle Rated Switchpack
Pre-terminatedControl Cables
Daylight Sensor
Entry Wallstation
TeacherWallstation
Occupancy CouplerDual Technology
CeilingOccupancy Sensor
Power Module
Greengate