YOU ARE DOWNLOADING DOCUMENT

Please tick the box to continue:

Transcript
Page 1: Greengate - Cooper Industries...P2 = Scene 1, Scene 2, Scene 3, Scene 4, Scene 5, All Off (6TSB) P3 V= All On, Scene 1, Scene 2, Scene 3, Scene 4, All Off (6TSB) P4 G= Scene 1, Scene

Project Catalog # Type

Prepared by Notes Date

PS503117EN page 1December 2019

Top Product Features Low-voltage control for ON/OFF and dimming loads Personalize the scene buttons with ON/OFF and dimming needs per output Pre-terminated control cable ready with RJ45 ports eliminate wiring errors

Custom engraving options available - buttons may be replaced in the field (10 character limit)

Interactive Menu• Order Information page 2

• Additional Resources page 3

• Wiring Diagrams page 3

• Product Warranty

Dimensional and Mounting Details Scale or Mounting Height

additionalproduct diagrams

GreengateScene Wallstation

Scene wallstations are pre-engraved low-voltage switches

48” / 1210mm

58” / 1470mm

All On

Scene 1

Scene 2

Scene 3

Scene 4

Pre-engraved buttonssimplify delivery

Color match screwlesswallplates included

RC-6TSB-P4

Programmablebuttons using

Personal Remote

All Off

3.25"[83mm]

1.4"[36mm]

2.8"[72mm]

1.8"[47mm]

4.75"[121mm]

Product Features

Page 2: Greengate - Cooper Industries...P2 = Scene 1, Scene 2, Scene 3, Scene 4, Scene 5, All Off (6TSB) P3 V= All On, Scene 1, Scene 2, Scene 3, Scene 4, All Off (6TSB) P4 G= Scene 1, Scene

Scene Wallstation

PS503117EN page 2December 2019

Order InformationSAMPLE ORDER NUMBER: RC-6TSB-P1-WOne single gang color matching wallplate is included in the package. Standard button engraving shown below. Engraving appears as black text on white, ivory, and gray buttons. Engraving appears as gold text on black buttons. If white engraved text is desired on black buttons use the configurator tool with the FlashPro software.

Catalog Number Number of Buttons Button Engraving Insert Color

Catalog Number Number of Buttons Button Engraving Insert Color

RC-6TSB-P1-W 3=Large Buttons – TLB6= Small Buttons – TSB

P1 = Scene 1, Scene 2, All Off (3TLB) P2 = Scene 1, Scene 2, Scene 3, Scene 4, Scene 5, All Off (6TSB) P3 = All On, Scene 1, Scene 2, Scene 3, Scene 4, All Off (6TSB) P4 = Scene 1, Scene 2, Scene 3, Raise, Lower, All Off (6TSB)

W= WhiteB= BlackV= IvoryG= Gray

NotesFor custom configurations or custom engraving, use the configurator tool within the FlashPro tool.

Additional Information

Catalog Number Description

Catalog Number Description

HHPR-RCLVHH-02

Room Controller Personal RemoteDLVP Personal Remote

Engraving Relay Style Zone / Dimmer 1 Zone / Dimmer 2 Zone / Dimmer 3 Address

All relays ON N/A N/A N/A N/A

Scene 1: All relays ON =50% =50% =50% 12

Scene 2: All relays ON =100% =100% =100% 13

Scene 3: All relays ON =50% =100% =50% 14

Scene 4: All relays ON =30% =0% =25% 15

Scene 5: All relays ON =20% =20% =20% 4

Scene 6: All relays ON =100% =100% =100% DIP #4

All relays OFF N/A N/A N/A N/A

Notes

* Button defaults when shipped.

** Not available in a wallstation configuration

Product SpecificationsMechanicalSize: 4.75” H x 3.25” W (121mm x 83mm)Environment:

• Operating temperature: 32°F to 104°F (0°C to 40°C)• Relative humidity operating: Less than 95%, non-condensing• For indoor use only

Connection Ports: Two RJ45 portsButton Configurations: • Large buttons: 2 or 3 • Small buttons: 2, 4, 5, 6Installation: • Standard decorator opening

ElectricalInput Requirements:

• Class 2, LPSVoltage: 24 VDC supplied from Room Controller

Standards • UL 508 Listed

WarrantyFive year warranty standard

Greengate

Page 3: Greengate - Cooper Industries...P2 = Scene 1, Scene 2, Scene 3, Scene 4, Scene 5, All Off (6TSB) P3 V= All On, Scene 1, Scene 2, Scene 3, Scene 4, All Off (6TSB) P4 G= Scene 1, Scene

Scene Wallstation

PS503117EN page 3December 2019

OverviewThe scene wallstations are pre-engraved low-voltage switches that operate on 24 VDC power supplied by the Room Controller or DLVP power module. Each scene wallstation is designed to fit in a standard decorator opening and has two RJ45 ports for local network connections to eliminate wiring errors.The scene wallstations are pre-terminated control cable ready and work immediately upon power up. Scene wallstations are fully functional out-of-the-box but can be customized to meet needs using a personal remote to adjust and save the scene settings.

InstallationLow-voltage devices are connected using pre-terminated control cables (ordered separately).

Sample Wallstations

RC-3TLB-P1-*Preset Wallstation

Scene 1

Scene 2

All Off

RC-6TSB-P2-*Preset Wallstation

Scene 5

Scene 3

Scene 4

Scene 2

Scene 1

All Off

RC-6TSB-P3-*Preset Wallstation

RC-6TSB-P4-*Preset Wallstation

Scene 4

Scene 2

Scene 3

Scene 1

All On

All Off

Lower

Scene 3

Raise

Scene 2

Scene 1

All Off

Wiring DiagramsRoom Controller Personal Remote DLVP Personal Remote

Zone Raise/

Lower

SETSaves current light levels to selected

Scene

Programmable Scene Buttons

Dimmer 1, 2, 3 Raise/Lower

Relay 1, 2, 3 ON/OFF

Scenes 1-6 Preset� S1 = Button Address 12� S2 = Button Address 13� S3 = Button Address 14� S4 = Button Address 15� S5 = Button Address 4� S6 = Auto On Scene (DIP #4 UP)

SETSaves Current light levels and relay

states to selected Scene

AUXOpen/Close Solatube/Shade Output

Room ControllerPersonal Remote

HHPR-RC

Zone Control

R1 R2 R3

SET AUXOpen/CloseShade or Solatube

S1 S2 S3

S4 S5 S6

To save scene pressSET and select Scene

Greengate

Page 4: Greengate - Cooper Industries...P2 = Scene 1, Scene 2, Scene 3, Scene 4, Scene 5, All Off (6TSB) P3 V= All On, Scene 1, Scene 2, Scene 3, Scene 4, All Off (6TSB) P4 G= Scene 1, Scene

Scene Wallstation

PS503117EN page 4December 2019

Cooper Lighting Solutions1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800www.cooperlighting.com

© 2020 Cooper Lighting Solutions All Rights Reserved.

Specifications and dimensions subject to change without notice.

Control Systems• Greengate

Sample Room Controller System Topology

Dual TechnologyWall/CornerOccupancy/Vacancy Sensor

20A Receptacle Control

RC-6TSB-TS7-*Teacher Station

Row 3

Lower

Raise

All Off

Row 1

Row 2

RC-2TLB-EC1-*

Entry

All Off

Adjustable daylight sensor dome

Daylight sensor

Ceiling

OCC-RJ45

Wal

l

Egress OutputOCC-RJ45

Up to 6 Lighting Zones(3 Relays and 3 Dimmers)

(or additional lighting zone)

(BMS integration)

Room Controller

Output for Egress LightingControl, BMS output orReceptable Control

BMS OutputOCC-RJ45

DS-FMOIR

RC3DE

OAWC-DT-120W

SPRC-R-20-120 Entry Station

Sample DLVP System Topology

Model: OCC-RJ45

Occupancy Sensor Coupler

Brown

Black

Red

Blue

All Off

Entry Lighting

General

Whiteboard

Quiet Time

Lower

Raise

A/V Mode

STA

TU

S

TE

ST

RE

SE

T

DEMAND+ -

CLOCK+ -

1

DEMANDRESPONSE

2 2

WALLSENSORS

SWITCHPACK

14 5 6

1 2

LOW VOLTAGE OUTPUTS

LOW HIGH TR

IM

3

RECBMS/OUT

ALERT+ -

Occ

/ Va

c

1

Part

ial O

nPa

rtia

l Off

Zo

ne

/ Are

a

2 3 4 5

10%

1

20%30%40%

2 3 4 5-

--

-

++

+

LL053001EN

V Y Y AO N N Z

+

Low-Voltage Light Fixtures

Low-Voltage Lighting Cables

Receptacle Rated Switchpack

Pre-terminatedControl Cables

Daylight Sensor

Entry Wallstation

TeacherWallstation

Occupancy CouplerDual Technology

CeilingOccupancy Sensor

Power Module

Greengate


Related Documents