YOU ARE DOWNLOADING DOCUMENT

Please tick the box to continue:

Transcript
Page 1: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

Ind

ex

Arlington

www.aifittings.com Email: [email protected] Tel: (800) 233-4717 Fax: (570) 562-06464

Part No. UPC No. Page Part No. UPC No. Page Part No. UPC No. Page Part No. UPC No. PageDBVME1WGC …08925 ………K-14DBVR131 ………14368 ………J-22DBVR131C………14370 ………K-5DBVR131CGC …08926 ………K-5DBVR131W ……14375 ………K-5 DBVR131WGC …08927 ………K-5 DBVR141 ………14379 ………J-22DBVR141C………14371 ………K-5DBVR141CGC …08992 ………K-5DBVR141W ……14376 ………K-5DBVR141WGC …08993 ………K-5DBVR151 ………14381 ………J-22DBVR151C………14372 ………K-5DBVR151CGC …08994 ………K-5DBVR151W ……14377 ………K-5DBVR151WGC …08995 ………K-5DBVR171 ………14383 ………J-22DBVR171C………14373 ………K-5DBVR171CGC …08928 ………K-5DBVR171W ……14378 ………K-5DBVR171WGC …08929 ………K-5DBVR1C…………14313 ………J-16DBVR1CGC ……08930 ………J-16DBVR1W ………14314 ………J-16DBVR1WGC ……08931 ………J-16DBVR2C…………03964 ………J-17DBVR2CGC ……08996 ………J-17DBVR2W ………03965 ………J-17DBVR2WGC ……08997 ………J-17DBVS1C…………14317 ………K-2DBVS1CGC ……08932 ………K-2DBVS1W ………14318 ………K-2DBVS1WGC ……08933 ………K-2DBVS2C…………03960 ………K-8DBVS2CGC ……08998 ………K-8DBVS2W ………03961 ………K-8DBVS2WGC ……08999 ………K-8DBVW……………77642 ………K-17DHB1BR…………54875 ………K-9DHB1BRC ………54881 ………K-9DHB1BRCGC …08935 ………K-9DHB1BRGC ……08934 ………K-9DHB1C …………54880 ………K-9DHB1CGC ………08936 ………K-9DHB1W …………54882 ………K-9DHB1WGC………12902 ………K-9DLN1 ……………43510…………I-7DLN10……………43511 …………I-7DLN2 ……………43520…………I-7DLN3 ……………43530…………I-7DLN4 ……………43540…………I-7DLN5 ……………43550…………I-7DLN6 ……………43560…………I-7DLN7 ……………43570…………I-7DLN8 ……………43580…………I-7DLN9 ……………43590…………I-7DR1………………01551 ………R-6DR2………………01552 ………R-6DR3………………01553 ………R-6DR4………………01554 ………R-6DSBHM1C ………09643 ………K-12DSBHM1W………09648 ………K-12DSBHS1C ………09652 ………K-11DSBHS1W………09653 ………K-11DSBHR1C ………09656 ………K-10DSBHR1W………09657 ………K-10DSBVM1C ………09642 ………K-12DSBVM1W………09646 ………K-12DSBVR1C ………09654 ………K-10DSBVR1W………09655 ………K-10DSBVS1C ………09650 ………K-11DSBVS1W ………09651 ………K-11DSC1 ……………43600 ………R-11DSC5 ……………43605 ………R-11DSHB1BR ………43613 ………K-13DSHB1BRC ……43612 ………K-13DSHB1C…………43610 ………K-13DSHB1W ………43611 ………K-13DSHS1W ………09653 ………J-19DV1 ………………43607 ………L-6DVB1BR…………43595 ………K-9DVB1BRC ………43608 ………K-9DVB1BRCGC …09001 ………K-9DVB1BRGC ……09002 ………K-9DVB1C …………43609 ………K-9DVB1CGC ………09003 ………K-9DVB1W …………43620 ………K-9DVB1WGC………09004 ………K-9DVFR1BL ………14329 ………P-8DVFR1BLGC……08938 ………P-9DVFR1W ………14330 ………P-9DVFR1WGC ……08939 ………P-9

DVFR2BL ………14335 ………P-9DVFR2BLGC……08940 ………P-9DVFR2W ………14331 ………P-9DVFR2WGC ……08941 ………P-9DVFR3BL ………14341 ………P-9DVFR3BLGC……09005 ………P-9DVFR3W ………14340 ………P-9DVFR3WGC ……09006 ………P-9DVFR4BL ………14343 ………P-9DVFR4BLGC……09007 ………P-9DVFR4W ………14342 ………P-9DVFR4WGC ……09008 ………P-9DVFRC …………14337 ………P-9DVFRBLC ………14336 ………P-9DW50 ……………06880 ………R-5DWB0805 ………06805 ………R-2DWB0812 ………06883 ………R-2DWB0815 ………06815 ………R-2DWB0820 ………06820 ………R-2DWB0830 ………06830 ………R-2DWH0805 ………15022 ………R-2DWH0810 ………15023 ………R-2DWT0805 ………15020 ………R-2DWT0810 ………15021 ………R-2DWY2H0810 ……11312 ………R-2DWY2T0810 ……11306 ………R-2DWY2T0812 ……11314 ………R-2DWYH0805 ……11307 ………R-2DWYH0810 ……11308 ………R-2DWYH0815 ……11309 ………R-2DWYH0820 ……11310 ………R-2DWYH0830 ……11311 ………R-2DWYT0805………11301 ………R-2DWYT0810………11302 ………R-2DWYT0812………11313 ………R-2DWTY0815………11303 ………R-2DWTY0820………11304 ………R-2DWTY0830………11305 ………R-2EE STRAP ………43625 ………C-4EB0708 …………12672 ………M-7EB1111 …………12670 ………M-7EB1212 …………12671 ………M-7EBL1 ……………11400 ………M-7EH200……………58201 ………F-2EH201……………43630 ………F-2EMT100 …………12220…B-1, O-11EMT100C ………12207 ………B-2EMT125 …………12225…B-1, O-11EMT125C ………12209 ………B-2EMT150 …………12230…B-1, O-11EMT150C ………12211 ………B-2EMT200 …………12235…B-1, O-11EMT200C ………12213 ………B-2EMT250 …………12240 …B-1, I-1,……………………………………O-11EMT250C ………12215……B-2, I-2EMT300 …………12245 …B-1, I-1,……………………………………O-11EMT300C ………12217……B-2, I-2EMT350 …………12250 …B-1, I-1,……………………………………O-11EMT350C ………12219……B-2, I-2EMT400 …………12255 …B-1, I-1,……………………………………O-11EMT400C ………12221……B-2, I-2EMT50 …………12200…B-1, O-11EMT50C …………12203 ………B-2EMT75 …………12205…B-1, O-11EMT75C …………12204 ………B-2FF101 ……………43626 ………P-6F101F ……………12520 ………P-8F101H……………43634 ………P-6F102 ……………43640 ………P-6F102D……………43544 ………P-6F102F ……………06900 ………P-8F103 ……………43641 ………P-6F103F ……………06901 ………P-8F104 ……………43642 ………P-6F104F ……………06902 ………P-8F426F ……………06903 ………Q-2F202N……………12522 ………R-3F202S ……………12523 ………R-3FA101 ……………04241 ………P-7FA102 ……………04242 ………P-7FA102D …………04245 ………P-7FA103 ……………04243 ………P-7FA104 ……………04244 ………P-7FAN/FIXTURE BOX RATING…Q-17

FB405 ……………72185 ………Q-9FB4050 …………28101 ………Q-9FB407 ……………72177 ………Q-9FB4070 …………28102 ………Q-9FB412 ……………72189 ………Q-9FB415 ……………72167………Q-12FB4150 …………72182………Q-12FB417S …………72171………Q-10FB417SLP ………72199………Q-10FB423 ……………72190 ………Q-9FB426 ……………72179………Q-12FB442 ……………72194………Q-13FB442F …………76220 ………Q-1FB442FD ………76221 ………Q-1FB443 ……………72197………Q-13FB443F …………76222 ………Q-1FB443FD ………76223 ………Q-1FB444 ……………72187………Q-11FB450 ……………75240………Q-15FB900 ……………75250………Q-15FBR415F ………72204 ………Q-1FBR425F ………72205 ………Q-1FBRS407R………72248 ………Q-8FBRS415 ………72250 ………Q-5FBRS4200R ……75325 ………Q-7FBRS420SC ……75300 ………Q-6FBS1423…………76190 ………Q-2FBS405 …………76185 ………Q-3FBS405T ………40500 ………Q-3FBS407 …………76187 ………Q-3FBS407T ………40700 ………Q-3FBS415 …………75204 ………Q-4FBS415S ………75206 ………Q-4FBS420 …………75200 ………Q-4FBS420S ………75202 ………Q-4FBX900 …………75224………Q-14FD1RP …………75229 ………P-17FD1RPGC ………08946 ………P-17FD2RP …………75301 ………P-17FD2RPGC ………08947 ………P-17FE102C …………01582 ………P-19FE102D …………01586 ………P-19FE102E …………01585 ………P-19FEN102 …………01580 ………P-19FER102 …………01583 ………P-19FER102C ………01854 ………P-19FES102 …………01581 ………P-19FL430 ……………09740 M-2, P-14FL430GC ………08948 M-2, P-14FL430S …………09741 M-2, P-14FLBA101BL ……04346 ………P-3FLBA101BLGC …52276 ………P-3FLBA101BR ……04347 ………P-3FLBA101BRGC…52277 ………P-3FLBA101LA ……04345 ………P-3FLBA101LAGC …52278 ………P-3FLBA101MB ……52259 ………P-4FLBA101MBGC…52268 ………P-4FLBA101SS ……52260 ………P-4FLBA101SSGC…52269 ………P-4FLBA101W………04344 ………P-3FLBA101WGC …52279 ………P-3FLBAF101BL……04342 ………P-3FLBAF101BLGC 52280 ………P-3FLBAF101BR……04343 ………P-3FLBAF101BRGC 52281 ………P-3FLBAF101LA……04341 ………P-3FLBAF101LAGC 52282 ………P-3FLBAF101W ……04340 ………P-3FLBAF101WGC 52283 ………P-3FLBAR101BL……04350 ………P-3FLBAR101BLGC 52284 ………P-3FLBAR101BR …04351 ………P-3FLBAR101BRGC 52285 ………P-3FLBAR101LA……04349 ………P-3FLBAR101LAGC 52286 ………P-3FLBAR101MB …52261 ………P-4FLBAR101MBGC 52270 ………P-4FLBAR101SS …52262 ………P-4FLBAR101SSGC 52271 ………P-4FLBAR101W ……04348 ………P-3FLBAR101WGC 52287 ………P-3FLBC101BL ……04354 ………P-1FLBC101BLGC…52288 ………P-1FLBC101BR ……04355 ………P-1FLBC101BRGC…52289 ………P-1FLBC101LA ……04353 ………P-1FLBC101LAGC…52290 ………P-1FLBC101MB ……52267 ………P-2FLBC101MBGC 52274 ………P-2FLBC101SS ……52266 ………P-2FLBC101SSGC…52275 ………P-2

FLBC101W………04352 ………P-1FLBC101WGC …52291 ………P-1FLBCF101BL……06953 ………P-1FLBCF101BLGC 52292 ………P-1FLBCF101BR …06952 ………P-1FLBCF101BRGC 52293 ………P-1FLBCF101W ……06950 ………P-1FLBCF101WGC 52295 ………P-1FLBCF101LA……06951 ………P-1FLBCF101LAGC 52294 ………P-1FLBR101BL ……04358 ………P-5FLBR101BLGC…52296 ………P-5FLBR101BR ……04359 ………P-5FLBR101BRGC…52297 ………P-5FLBR101LA ……04357 ………P-5FLBR101LAGC…52298 ………P-5FLBR101MB ……52263 ………P-5FLBR101MBGC 52272 ………P-5FLBR101SS ……52264 ………P-5FLBR101SSGC…52273 ………P-5FLBR101W………04356 ………P-5FLBR101WGC …52299 ………P-5FLC430 …………09742 ………M-3FLC430GC………08949 ………M-3FLC430S ………09743 ………M-3FLEX•AC•MC CABLE RANGESE-22FLG3 ……………01590 ………R-2FN101F …………15130 ………P-8FN101FD ………15131 ………P-8FN102F …………15132 ………P-8FN102FD ………15133 ………P-8FN103F …………15134 ………P-8FN103FD ………15135 ………P-8FN104F …………15136 ………P-8FN104FD ………15137 ………P-8FN430F …………15100 ………Q-2FN440F …………15120 ………Q-2FR101F …………12680 ………L-8FR405F …………12681 ………L-8FR420F …………09615 ………L-8FS420SCL ………12526 ………Q-6FS427SCL ………12537 ………Q-6FS50 ……………61050 ………K-17FS75 ……………61075 ………K-17FS8091F…………17304 ………L-7FS8091FGC ……08950 ………L-7FS8141 …………17340 ………L-9FS8141GC………08951 ………L-9FS8151 …………17341 ………L-9FS8151GC………08952 ………L-9FS8161 …………17342 ………L-9FS8161GC………09009 ………L-9FS8171 …………17343 ………L-9FS8171GC………08953 ………L-9FSC3212R ………43633 ………P-16FSC3227R ………12525 ………P-16FSR404BL ………00596 ………P-18FSR404RD………00598 ………P-18FSR404S ………00597 ………P-18FSR404SRD ……00599 ………P-18FSR404SRD ……00600 ………P-18GGB5………………76095 ………G-1GB5P ……………09720 ………G-2GBB5 ……………76096 ………G-1GBB5P …………09721 ………G-2GBB50 …………09725 ………G-1GBB50P …………09726 ………G-2GF100……………76100 ………E-17GF100A …………76101 ………E-18GF125……………76125 ………E-17GF125A …………76251 ………E-18GF150……………76150 ………E-17GF150A …………76151 ………E-18GF200……………76200 ………E-17GF200A …………76201 ………E-18GF38 ……………76380 ………E-17GF38A……………76381 ………E-18GF38AST ………80164 ………E-18GF38ST …………80162 ………E-18GF50 ……………76500 ………E-17GF50A……………76501 ………E-18GF50AST ………80168 ………E-18GF50ST …………80166 ………E-18GF75 ……………76750 ………E-17GF75A……………76751 ………E-18GF75ST …………80170 ………E-18GF850……………85000 ………E-21GF850ST ………84850 ………E-21GF860……………76860…B-7, E-19GF861……………76861…B-7, E-19

Arlington_TOC_TOC_AND_INDEX.qxd 1/3/13 8:51 AM Page 4

Page 2: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

Ind

ex

Arlington

5Fax: (570) 562-0646 Tel: (800) 233-4717 Email: [email protected] www.aifittings.com

Part No. UPC No. Page Part No. UPC No. Page Part No. UPC No. Page Part No. UPC No. PageGF862……………76862…B-7, E-19GF863……………80173…B-7, E-19GF864……………80175 ………B-8GFC100 …………76340 ………E-17GFC125 …………76360 ………E-17GFC150 …………76370 ………E-17GFC200 …………76372 ………E-17GFC50 …………76350 ………E-17GFC75 …………76375 ………E-17GFSC38 …………20737 ………E-15GFSC38B ………20739 ………E-15GL100……………77100 ………G-4GL125……………77125 ………G-4GL150……………77150 ………G-4GL200……………77200 ………G-4GL250……………77250 ………G-4GL300……………77300 ………G-4GL350……………77350 ………G-4GL400……………77400 ………G-4GL50 ……………77050 ………G-4GL75 ……………77075 ………G-4GP19B …………77086 ………J-1GP19BGC ………08954 ………J-1GP19BR …………77087 ………J-1GP19BRGC ……08955 ………J-1GP19G …………77088 ………J-1GP19GGC ………08956 ………J-1GP19W …………77089 ………J-1GP19WGC………09010 ………J-1GP26B …………77090 ………J-1GP26BGC ………08957 ………J-1GP26BR …………77092 ………J-1GP26BRGC ……08958 ………J-1GP26G …………77094 ………J-1GP26GGC ………09011 ………J-1GP26W …………77096 ………J-1GP26WGC………09012 ………J-1GP37B …………76153 ………J-4GP37BGC ………08959 ………J-4GP37BR …………76154 ………J-4GP37BRGC ……08960 ………J-4GP37G …………76156 ………J-4GP37GGC ………09013 ………J-4GP37W …………76155 ………J-4GP37WGC………08961 ………J-4GPBK35B ………77040 ………J-3GPBK35BGC……08962 ………J-3GPBK35BR ……77041 ………J-3GPBK35BRGC …08963 ………J-3GPBK38B ………76130 ………J-6GPD19B …………77020 ………J-2GPD19BGC ……09014 ………J-2GPD19BR ………77021 ………J-2GPD19BRGC……08964 ………J-2GPD19G…………77022 ………J-2GPD19GGC ……08965 ………J-2GPD19W ………77023 ………J-2GPD19WGC ……09015 ………J-2GPD9B …………76161 ………J-5GPD9BGC ………08966 ………J-5GPD9BR…………76162 ………J-5GPD9BRGC ……04685 ………J-5GPD9G …………76164 ………J-5GPD9GGC………04686 ………J-5GPD9W …………76163 ………J-5GPD9WGC………08967 ………J-5GPL19B …………77000 ………J-6GPL19BR ………77001 ………J-6GPL19G …………77002 ………J-6GPL19W…………77003 ………J-6GPLN15B ………76205 ………J-7GPLN15GR ……76181 ………J-7GPLN19B ………69108 ………J-7GPLN19BR ……76192 ………J-7GPX18B …………76157 ………J-6GPX18BR ………76158 ………J-6GPX18G…………76160 ………J-6GPX18W…………76159 ………J-6HH STRAP ………82990 ………C-4HL100 ……………50171……B-8, I-6HL125 ……………50173……B-8, I-6HL5000 …………83105……B-8, I-6HL7500 …………83175……B-8, I-6JJC12 ……………13120………R-12KK STRAP ………83770 ………C-4KC4 ………………83665 ………G-7

KC6 ………………83667 ………G-7KD4550 …………83668 ………O-5LL15A ……………80040 ………E-12L15AST …………80044 ………E-4L16 ………………80060 ………E-12L160 ……………02416 ………E-12L160ST …………80065 ………E-4L16ST ……………80064 ………E-4L17 ………………34278 ………E-12L17ST ……………33905 ………E-4L18 ………………34282 ………E-12L18ST ……………33915 ………E-4L19 ………………34287 ………E-12L19ST ……………08650 ………E-4L20 ………………32000 ………B-1L42 ………………34200 ………E-9L420 ……………34021 ………E-9L421 ……………34210 ………E-9L4210 ……………34211 ………E-9L4210A …………42100 ………E-9L421A ……………34212 ………E-9L422 ……………34220 ………E-9L422A ……………34213 ………E-9L423 ……………34230 ………E-9L423A ……………34214 ………E-9L424 ……………34240 ………E-9L424A ……………34215 ………E-9L425 ……………34250 ………E-9L425A ……………34216 ………E-9L426 ……………34260 ………E-9L426A ……………34217 ………E-9L427 ……………34270 ………E-9L427A ……………42700 ………E-9L428 ……………34280 ………E-9L428A ……………42800 ………E-9L429 ……………34290 ………E-9L429A ……………42900 ………E-9L48 ………………34800 ………E-11L49 ………………34900 ………E-11LPCG50 …………80086 ………D-1LPCG503 ………50350 ………D-1LPCG503BL ……50351 ………D-1LPCG503Z………50352 ………D-1LPCG507 ………50354 ………D-1LPCG507BL ……50353 ………D-1LPCG507Z………50356 ………D-1LPCG50BL………06070 ………D-1LPCG50Z ………36110 ………D-1LPCG753 ………50760 ………D-1LPCG753BL ……07450 ………D-1LPCG753Z………36105 ………D-1LPCG754 ………50762 ………D-1LPCG754BL ……07455 ………D-1LPCG754Z………50764 ………D-1LPCG757 ………36100 ………D-1LPCG757BL ……07460 ………D-1LPCG757Z………50766 ………D-1LT10 ……………32102 ………A-2LT100 ……………32100 ………A-7LT100A …………32101 ………A-7LT10A ……………35087 ………A-2LT125 ……………32125 ………A-7LT125A …………32121 ………A-7LT150 ……………32150 ………A-7LT150A …………32151 ………A-7LT200 ……………32200 ………A-7LT200A …………32201 ………A-7LT250 ……………32250 ………A-7LT300 ……………32300 ………A-7LT350 ……………32350 ………A-7LT38 ……………32380 ………A-7LT38A ……………32381 ………A-7LT400 ……………32400 ………A-7LT5 ………………32502 ………A-2LT50 ……………32500 ………A-7LT50A ……………32501 ………A-7LT5A ……………35085 ………A-2LT7 ………………32503 ………A-2LT75 ……………32750 ………A-7LT75A ……………32751 ………A-7LT7A ……………38086 ………A-2LT9010 …………32104 ………A-2LT90100 …………32910 ………A-8LT90100A ………32911 ………A-8LT9010A…………35090 ………A-2LT90125 …………32913 ………A-8LT90125A ………32912 ………A-8LT90150 …………32915 ………A-8LT90150A ………32955 ………A-8LT90200 …………32920 ………A-8

LT90200A ………32921 ………A-8LT90250 …………32925 ………A-8LT90300 …………32930 ………A-8LT90350 …………32935 ………A-8LT9038 …………32938 ………A-8LT9038A…………32931 ………A-8LT90400 …………32940 ………A-8LT905 ……………32504 ………A-2LT9050 …………32950 ………A-8LT9050A…………32951 ………A-8LT905A …………24233 ………A-2LT505A …………24233 ………A-2LT907 ……………32505 ………A-2LT9075 …………32970 ………A-8LT9075A…………32971 ………A-8LT907A …………35089 ………A-2LTSC50 …………35405 ………A-3LTSC75 …………35408 ………A-3LV1 ………………58175 ………O-1LV1LP ……………58177 ………O-2LV2 ………………10952 ………O-1LV2LP ……………23102 ………O-2LV3 ………………09600 ………O-1LV4 ………………09601 ………O-1LVD2 ……………10957 ………P-15LVDR2……………01000 ………P-15LVH1 ……………10979 ………O-4LVH1K……………10984 ………O-4LVMB1 …………14364 ………O-4LVMB2 …………14365 ………O-4LVN1 ……………00261 ………O-3LVN2 ……………00275 ………O-3LVN3 ……………00277 ………O-3LVN4 ……………00278 ………O-3LVS1 ……………00262 ………O-3LVS2 ……………00280 ………O-3LVS3 ……………00282 ………O-3LVS4 ……………00283 ………O-3MMB8………………42330………Q-16MBC25 …………34810………R-12MBC25A…………42321………R-12MBC26 …………42326………R-12MBC27 …………42327………R-12MBC28 …………42328………R-12MCI-A CABLE RANGES ………E-25MK200……………42200 ………F-8MK200ASF………42210 ………F-8MK200PS ………32044 ………F-8MK200WH ………42205 ………F-8MK250A …………32027 ………F-8MK250ASF………42250 ………F-8MK250ASFX ……42255 ………F-8MM10 ……………42278 ………L-10MM18 ……………42280 ………L-10MM23 ……………42282 ………L-10NNM CABLE RANGES …………C-12NM1000 …………54615…………I-9NM1900 …………54514…………I-9NM2000 …………54515…………I-9NM2005 …………54525…………I-9NM2010 …………54516…………I-9NM2015 …………54526…………I-9NM2020 …………54517…………I-9NM2025 …………54518…………I-9NM2030 …………54528…………I-9NM2040 …………54519…………I-9NM2045 …………54544…………I-9NM2050 …………54520…………I-9NM2060 …………54521…………I-9NM2070 …………54522…………I-9NM2080 …………54523…………I-9NM2090 …………54524…………I-9NM2150 …………54547…………I-9NM2520 …………54565 ………R-6NM310 …………54010 ………E-21NM501 …………54501…………I-3NM501EL ………54584…………I-3NM502 …………54502…………I-3NM503 …………54503…………I-3NM504 …………54504…………I-3NM505 …………54505…………I-3NM506 …………54506…………I-3NM74 ……………54510 ………C-7NM75 ……………54513 ………C-7NM840 …………54840 ………C-7NM841 …………54841 ………C-7NM842 …………54842 ………C-7NM843 …………54843 ………C-7

NM844 …………50175 ………C-7NM900 …………54000………R-10NM901 …………54001………R-10NM902 …………54002………R-10NM903 …………54003………R-10NM904 …………54004………R-10NM905 …………54005………R-10NM94 ……………05488 ………C-8NM940 …………72156 ………C-8NM95 ……………10956 ………C-8NM96 ……………72158 ………C-8NMCG100750 …55000 ………D-2NMCG100750BL 06072 ………D-2NMCG100875 …55002 ………D-2NMCG100875BL 06074 ………D-2NMFS50 …………54050 ………K-17NMFS75 …………54075 ………K-17NMLT10 …………54102 ………A-1NMLT100 ………54100 ………A-5NMLT100BL ……06112 ………A-5NMLT125 ………04223 ………A-5NMLT125BL ……06114 ………A-5NMLT150 ………04222 ………A-5NMLT150BL ……06116 ………A-5NMLT200 ………04221 ………A-5NMLT200BL ……06118 ………A-5NMLT38 …………54380 ………A-5NMLT38BL………06120 ………A-5NMLT45100 ……54110 ………A-6NMLT45100BL …06122 ………A-6NMLT45125 ……54125 ………A-6NMLT45125BL …06124 ………A-6NMLT45150 ……54150 ………A-6NMLT45150BL …06128 ………A-6NMLT45200 ……54200 ………A-6NMLT45200BL …54200 ………A-6NMLT4538 ………54538 ………A-6NMLT4538BL……06130 ………A-6NMLT4550 ………54550 ………A-6NMLT4550BL……06132 ………A-6NMLT4575 ………54575 ………A-6NMLT4575BL……06134 ………A-6NMLT5 …………54576 ………A-1NMLT50 …………54500 ………A-5NMLT50BL………06136 ………A-5NMLT5090 ………06240 ………A-4NMLT590 ………03900 ………A-3NMLT590BL ……03900 ………A-3NMLT7 …………54577 ………A-1NMLT75 …………54750 ………A-5NMLT75BL………06138 ………A-5NMLT7590 ………06260 ………A-4NMLT790 ………03902 ………A-3NMLT790BL ……03902 ………A-3NMLT9010 ………54104 ………A-1NMLT90100 ……54901 ………A-6NMLT90100BL …06140 ………A-6NMLT90125 ……54912 ………A-6NMLT90125BL …06142 ………A-6NMLT90150 ……54915 ………A-6NMLT90150BL …06144 ………A-6NMLT90200 ……54920 ………A-6NMLT90200BL …06146 ………A-6NMLT9038 ………54903 ………A-6NMLT9038BL……06148 ………A-6NMLT905 ………54578 ………A-1NMLT9050 ………54905 ………A-6NMLT9050BL……06152 ………A-6NMLT907 ………54579 ………A-1NMLT9075 ………54907 ………A-6NMLT9075BL……06154 ………A-6NMPV100 ………76870 ………D-3NMPV125 ………76871 ………D-3NMSC38…………21005 ………A-5NMSC38BL ……21008 ………A-5NMSC50…………21000 ………A-5NMSC50BL ……21002 ………A-5NMSC75…………21010 ………A-5NMSC75BL ……21011 ………A-5NMSC9038………21003 ………A-5NMSC9038BL …33805 ………A-5NMSC9050………21007 ………A-5NMSC9050BL …33810 ………A-5NMSC9075………21009 ………A-5NMSC9075BL …33815 ………A-5NMUF50…………55040 ………C-5NMUF75…………54367 ………C-5PPVC1020 ………73146 ………F-1PVC1040 ………73147 ………F-1PVC105 …………73105 ………F-1

Arlington_TOC_TOC_AND_INDEX.qxd 1/3/13 8:51 AM Page 5

Page 3: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

Ind

ex

& S

tan

da

rds

Arlington

www.aifittings.com Email: [email protected] Tel: (800) 233-4717 Fax: (570) 562-06466

PRODUCT UL STANDARD UL FILE UL CONTROL CSA FILE FED SPEC NEMAGROUP NUMBER NUMBER NUMBER NUMBER NUMBER STANDARD

Liquid-Tight UL 514B E60812 351F LR49636 A-A-50552 FB-1FittingsEMT Fittings UL 514B E20643 365D LR49636 A-A-50553 FB-1

Non-Metallic UL 514B E28474 388D LR49636 A-A-50552 FB-1Cable ConnectorsFlexible Cord UL 514B E105706 1B64 LR49636 A-A-50552 FB-1ConnectorsArmored UL 514B E18304 372D LR49636 A-A-50552 FB-1Cable ConnectorsService Entrance UL 514B E66990 282F LR49636 A-A-50563 FB-1Cable FittingsGrounding and UL 467 E75814 910F LR49636 A-A-50552 FB-1Bonding EquipmentConduit Bodies UL 514A E28474 5B36 LR49636 A-A-50563 FB-1

UL 514BConduit UL 514B E60812 351F LR49636 A-A-50553 FB-1Fittings-RigidMC Cable UL 514B E123751 388E LR49636 A-A-50552 FB-1ConnectorsGrounding Lugs UL 514B E86540 910F LR49636 A-A-50552 FB-1

Flush Device UL 514A E48106 910F LR49636 A-A-50563 FB-1Box Covers

Non-Metallic UL 514C E170558 6D39 LR49636 A-A-50563 FB-1Outlet Boxes

STANDARDS

PVC106 …………12512 ………F-1PVC129 …………73129 ………F-1PVC660 …………73660 ………F-2PVC662 …………73662 ………F-2PVC85……………00085 ………F-4RRGD100 …………51933 …I-1, O-11RGD100C ………51939…………I-2RGD125 …………51934 …I-1, O-11RGD125C ………51940…………I-2RGD150 …………51935 …I-1, O-11RGD150C ………51941…………I-2RGD200 …………51936 …I-1, O-11RGD200C ………51942…………I-2RGD50 …………51930 …I-1, O-11RGD50C…………51937…………I-2RGD75 …………51932 …I-1, O-11RGD75C…………51938…………I-2RTS12……………10490 ………R-1RTS1221 ………10491 ………R-1RTS4 ……………10492 ………R-1RTS402 …………00916 ………R-1RTS421 …………10493 ………R-1RTSB1209 ………00912 ………R-1RTSB405 ………00910 ………R-1RTSB409 ………00911 ………R-1RTSE1209 ………00912 ………R-1RTSE405 ………00914 ………R-1RTSE409 ………00915 ………R-1RW1 ……………95100…………I-8RW10 ……………95101…………I-8RW11 ……………95110 …………I-8RW12 ……………95120…………I-8RW13 ……………95130…………I-8RW14 ……………95140…………I-8RW15 ……………95150…………I-8RW16 ……………95160…………I-8RW17 ……………95170…………I-8RW18 ……………95180…………I-8RW19 ……………95190…………I-8RW2 ……………95200…………I-8RW20 ……………95201…………I-8RW21 ……………95210…………I-8RW22 ……………95220…………I-8RW23 ……………95230…………I-8RW24 ……………95240…………I-8RW25 ……………95250…………I-8RW26 ……………95260…………I-8RW27 ……………95270…………I-8RW28 ……………95280…………I-8

RW29 ……………95290…………I-8RW3 ……………95300…………I-8RW30 ……………95301…………I-8RW31 ……………95310…………I-8RW32 ……………95320…………I-8RW33 ……………95330…………I-8RW34 ……………95340…………I-8RW35 ……………95350…………I-8RW36 ……………95360…………I-8RW37 ……………95370…………I-8RW38 ……………95380…………I-8RW39 ……………95390…………I-8RW4 ……………95400…………I-8RW40 ……………95401…………I-8RW41 ……………95410…………I-8RW42 ……………95420…………I-8RW43 ……………95430…………I-8RW44 ……………95440…………I-8RW45 ……………95450…………I-8RW5 ……………95500…………I-8RW6 ……………95600…………I-8RW7 ……………95700…………I-8RW8 ……………95800…………I-8RW9 ……………95900…………I-8SSB1 ………………18001 …C-9, R-9SB10 ……………18010 …C-9, R-9SB13 ……………40115 C-9, O-12,……………………………………R-9

SB130……………40130 C-9, O-12,……………………………………R-9

SB3 ………………18050 …C-9, R-9SB30 ……………18053 …C-9, R-9SBS………………18055………R-12SC100……………06300 ………R-2SC5 ………………18058 ………M-4SG38 ……………18065 ………E-13SG380……………18060 ………E-13SG380A …………80140 ………E-13SG380AST………80148 ………E-13SG3838 …………17383 ………E-12SG3838A ………36205 ………E-12SG3838AST ……36210 ………E-12SG3838ST ………80152 ………E-12SG38A …………80138 ………E-13SG38AST ………80144 ………E-13SG40 ……………01740 ………E-13SG50 ……………07500 ………E-13SG50A …………37501 ………E-13SG50AST ………17501 ………E-13

SG50ST …………80150 ………E-13SG75 ……………18075 ………E-13SG75A …………17751 ………E-13SG75AST ………17755 ………E-13SG75ST …………18080 ………E-13SL100 ……………13100…………I-7SL125 ……………13125…………I-7SL150 ……………13150…………I-7SL200 ……………13200…………I-7SL250 ……………13250…………I-7SL300 ……………13300…………I-7SL350 ……………13350…………I-7SL400 ……………13400…………I-7SL50 ……………13500…………I-7SL500 ……………13501…………I-7SL600 ……………13600…………I-7SL75 ……………13750…………I-7SMC4 ……………42305 ………E-5SMC4F …………42315 ………E-5SMC8 ……………42307 ………E-5SP100……………17100………R-12SP360……………17360 ………F-4SP362……………17361 ………F-4SP363……………17362 ………F-4SP364……………17363 ………F-4SP365……………17364 ………F-4TT205 ……………38060 ………C-1T23A ……………38065 ………C-1T23C ……………38061 ………C-1T23E ……………38062 ………C-1T23F ……………38066 ………C-1T23H ……………38063 ………C-1T23T ……………38067 ………C-1T23W ……………38068 ………C-1TL20 ……………38084 ………O-9TL20P ……………38087 ………O-9TL25 ……………38085 ………O-9TL25P ……………38088 ………O-9TL50 ……………38086 ………O-9TL50P ……………38089 ………O-9TVB613 …………09630 ………N-4TVB613BL ………09634 ………N-4TVB613BLGC …08969 ………O-7TVB613C ………09631 …N-2, N-3,………………………N-4, P-10, P-12TVB613GC………08968 ………O-7TVB712 …………09712…N-3, P-12TVB712BK ………12781…N-5, P-13TVB712BKGC …12782…N-5, P-13

TVB713 …………09713…N-3, P-12TVB810 …………24184 ………N-6TVB810GC………24185 ………N-6TVBR505K………09682…N-1, P-11TVBR505KGC …08973…N-1, P-11TVBRA1K ………24180…N-5, P-13TVBRA1KGC……24182…N-5, P-13TVBRA2K ………24181…N-5, P-13TVBRA2KGC……24183…N-5, P-13TVBRA3K ………24195…N-5, P-13TVBRA3KGC……24196…N-5, P-13TVBS505 ………37955…N-2, P-10TVBS507 ………37956…N-2, P-10TVBS613 ………09633…N-2, P-10TVBS613BL ……09660…N-2, P-10TVBU505 ………09680…N-1, P-11TVBU505BL ……09681…N-1, P-11TVBU505BLGC…08975…N-1, P-11TVBU505GC ……08974…N-1, P-11TVBU507 ………09661…N-1, P-11TVBU507BL ……09662…N-1, P-11TVBU507BLGC…08977…N-1, P-11TVBU507GC ……08976…N-1, P-11UUF50 ……………36500 ………C-5UF75 ……………51302 ………C-5WWB112 …………52952 ………O-2WB200 …………52953 ………O-2WB500 …………52950 ………O-2WB875 …………52950 ………O-2WC1001 …………53101 ………C-5WTC100 …………58732………C-12WTC125 …………58733………C-12WTC150 …………58734………C-12WTC200 …………58735………C-12WTC210 …………58736………C-12WH1 ……………58100…………I-6WH10 ……………58101…………I-6WH11 ……………58103…………I-6WH12 ……………58105…………I-6WH2 ……………58200…………I-6WH3 ……………58300…………I-6WH4 ……………58400…………I-6WH5 ……………58500…………I-6WH6 ……………58600…………I-6WH7 ……………58700…………I-6WH8 ……………58800…………I-6WH9 ……………58900…………I-6

Part No. UPC No. Page Part No. UPC No. Page Part No. UPC No. Page Part No. UPC No. Page

Arlington_TOC_TOC_AND_INDEX.qxd 1/3/13 8:51 AM Page 6

Page 4: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

Sp

ecifica

tion

s & P

ate

nts

Arlington

7Fax: (570) 562-0646 Tel: (800) 233-4717 Email: [email protected] www.aifittings.com

D663,2748,212,144D659,6448,158,8828,148,6358,148,6348,124,8918,124,8738,091,7218,087,6318,076,5788,076,5758,076,5738,067,7038,063,3028,044,3007,954,5387,942,6797,897,8707,882,8867,854,6277,847,190D627,317D627,3057,834,2677,820,9117,816,604D620,786D620,3467,759,5767,735,7947,591,6567,586,039

7,582,8277,563,9797,537,4677,531,7457,528,3227,525,0437,518,0617,495,1847,488,8917,485,8067,485,8057,476,8077,470,8597,462,7757,446,2667,442,0797,435,9007,429,0257,407,1387,402,7487,390,9807,388,1627,381,0887,374,2127,355,1187,350,6597,347,4017,329,1447,319,1927,312,3957,307,2147,307,2137,607,212

7,304,2517,304,2407,304,2367,604,2357,294,7817,262,3707,259,3377,259,3287,238,8947,234,6707,227,0857,226,3097,216,8387,214,8757,176,3777,166,8017,161,0957,154,0547,151,2197,135,6407,117,5917,115,8207,109,4197,098,3997,087,8377,080,8597,077,280D524,6357,075,0047,064,2717,060,9007,060,898D522,347

7,045,7137,038,1317,036,9607,025,3117,021,5917,009,1107,005,5786,978,9736,967,2846,965,0786,957,9686,956,1716,956,1706,951,9836,935,8906,932,3906,924,4316,921,8616,915,9926,863,2516,857,6066,849,8036,806,4266,794,5736,780,1006,780,0296,779,7646,777,6156,774,3046,770,8116,768,0716,767,0326,752,362

6,742,7486,740,8136,734,3566,709,2806,682,3556,677,5236,670,5536,655,6446,646,2016,642,4516,632,9986,629,6766,624,3556,616,1946,607,0866,604,4006,600,1176,596,9396,585,2216,581,8846,538,2016,521,8316,517,0326,513,7666,511,0286,509,5246,460,8136,452,8136,452,0986,422,7816,386,4896,382,5716,380,489

6,378,8136,369,3226,355,8876,355,8846,355,8836,355,8826,352,4396,346,6746,335,4886,313,4066,310,2906,307,1546,281,4346,268,5636,263,619D443,4996,239,3686,222,1286,213,3166,204,4476,194,6616,194,657D438,1756,191,3626,180,8796,180,8786,177,6336,173,9356,152,4136,143,9826,133,5296,114,6316,114,630

6,112,9276,102,4426,100,4706,093,890D427,8896,080,9336,051,7866,044,8686,043,4326,028,2686,005,1905,988,5705,959,2465,939,6805,939,6715,916,094D407,9635,823,4825,804,7645,775,7395,773,7605,765,7865,736,6745,693,9105,628,0875,596,1775,543,5825,539,1525,442,1415,410,104

Arlington’s metallic SNAP-TITE® & SNAP2IT® products have been tested and listed by ULin accordance with UL’s ground fault requirements.

N.E.C. 2011. 250.97. Bonding for Over 250 Volts. For circuits of over 250 volts to ground,the electrical continuity of metal raceways and cables with metal sheaths that contain anyconductor other than service conductors shall be ensured by one or more of the methodsspecified for services in 250.92(B), except for (B)(1).

Exception: Where oversized, concentric, or eccentric knockouts are not encountered, orwhere a box or enclosure with concentric or eccentric knockouts is listed to provide apermanent, reliable bond, the following methods shall be permitted:

(1) Threadless couplings and connectors for cables with metal sheaths

(2) Two locknuts, on rigid metal conduit or intermediate metal conduit, one inside and one outside of boxes and cabinets

(3) Fittings with shoulders that seat firmly against the box or cabinet, such as electricalmetallic tubing connectors, flexible metal conduit connectors, and cable connectors, withone locknut on the inside of boxes and cabinets

(4) Listed fittings

SNAP-TITE®&SNAP2IT®Products Note

PATENT NUMBERS Arlington products are covered by one or more of the following U.S. and foreignpatents. Additional patents pending.

Arlington_TOC_TOC_AND_INDEX.qxd 1/3/13 8:51 AM Page 7

Page 5: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

Liq

uid

Tig

ht

Arlington

www.aifittings.com Email: [email protected] Tel: (800) 233-4717 Fax: (570) 562-0646A-1

BA

C

SNAP2IT®

Non-MetallicConnectorsFor use with non-metallic liquid-tight conduit, type B only.Push on installation. Producedfrom UV rated plastic for longoutdoor life.

90° SNAP2IT®

Non-MetallicConnectorsFor use with non-metallic liquid-tight conduit, type B only.Push on installation. Producedfrom UV rated plastic for long outdoor life.

R

R

E60812 LR49636

C

A

B

E60812 LR49636

PUSHES ONTO

CONDUIT...NO TOOLS! To install, simply PUSH ON to conduit. That’s it!

• Competitively priced• Fast and easy installation• Provides a super-secure, liquid-tight seal• Removable and reusable!

Fast and easy installation (see above)

R

R

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

NMLT5 54576 1/2 1/2 25 100 2.376 .619 1.420NMLT7 54577 3/4 3/4 10 50 2.425 .670 1.664NMLT10 54102 1 1 5 25 2.530 .708 1.856

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

NMLT905 54578 1/2 1/2 10 50 2.331 .605 3.389NMLT907 54579 3/4 3/4 10 50 2.682 .670 3.645NMLT9010 54104 1 1 5 25 2.874 .708 4.107

Installation Instructions

Scan For Video

Section_A_Liquid Tight 11/5/12 12:37 PM Page 1

Page 6: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

Liq

uid

Tig

ht

Arlington

A-2Fax: (570) 562-0646 Tel: (800) 233-4717 Email: [email protected] www.aifittings.com

Fast and easy installation (see page A-1)

A

With Insulated Throat

Fast and easy installation (see page A-1)

SNAP2IT®

Zinc ConnectorsFor use with metallic and non-metallic liquid-tightconduit, type B. Push oninstallation.

E60812 LR49636

C

AB

90° SNAP2IT®

Zinc ConnectorsFor use with metallic and non-metallic liquid-tightconduit, type B. Push oninstallation.

E60812 LR49636

B

C

With Insulated Throat

E60812 LR49636

E60812 LR49636

LT5

LT905

LT905A

LT5A

R

R

R

R

R

R

R

R

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

LT5 32502 1/2 1/2 25 100 2.376 .619 1.420LT7 32503 3/4 3/4 10 50 2.425 .670 1.664LT10 32102 1 1 5 25 2.495 .708 1.890

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

LT5A 35085 1/2 1/2 25 100 2.376 .619 1.420LT7A 35086 3/4 3/4 10 50 2.425 .670 1.664LT10A 35087 1 1 5 25 2.495 .708 1.890

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

LT905 32504 1/2 1/2 10 50 2.331 .605 3.389LT907 32505 3/4 3/4 10 50 2.682 .670 3.645LT9010 32104 1 1 5 25 2.874 .708 4.107

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

LT905A 24233 1/2 1/2 10 50 2.331 .605 3.389LT907A 35089 3/4 3/4 10 50 2.682 .670 3.645LT9010A 35090 1 1 5 25 2.874 .708 4.107

Scan For Video

Scan For Video

Section_A_Liquid Tight 11/5/12 12:37 PM Page 2

Page 7: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

Liq

uid

Tig

ht

Arlington

www.aifittings.com Email: [email protected] Tel: (800) 233-4717 Fax: (570) 562-0646A-3

One-PieceScrew-In LiquidTight ConnectorsFor use with metallic andnon-metallic liquid-tightconduit, type B only.

E60812 LR49636B

A• Costs 20% less than multi-piece fittings• Fast and easy screw-on installation• One-piece, low profile construction• Built-in gasket maintains liquid-tight seal• No tools required

TM

Add suffix “BL” to Catalog # when ordering in black, for example NMLT590BL. Factory order only. Minimum quantities required.

SNAP2IT®

Zero to 90™

Non-MetallicConnectorsFor use with non-metallic liquid-tight conduit, type B only. Push on installation. Produced from UV rated plasticfor long outdoor life. E60812 LR49636

B

A C

D

PUSHES ONTO

CONDUIT...NO TOOLS!

Adjusts for ALL ANGLES...from 0° to 90°!To adjust the anglesimply loosen thecenter nut, twist to thecorrect angle, andretighten.

R

R

R

R

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

DIMD

NMLT590 03900 1/2 1/2 10 50 3.165 2.435 3.594 2.007NMLT790 03902 3/4 3/4 10 50 3.875 2.900 4.200 2.623

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

LTSC50 35405 1/2 1/2 25 100 .525 1.535LTSC75 35408 3/4 3/4 25 100 .525 1.535

Section_A_Liquid Tight 11/5/12 12:37 PM Page 3

Page 8: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

Liq

uid

Tig

ht

Arlington

A-4Fax: (570) 562-0646 Tel: (800) 233-4717 Email: [email protected] www.aifittings.com

Zero to 90™

ConnectorsFor use with non-metallic liquid-tight conduit, type B only.Produced from UV ratedplastic for long outdoor life.

E60812 LR49636

D

C

A

B

COSTS THE SAME

AS OUR “REGULAR”

90° FITTING!

Installation InstructionsArlington’s no-spin ferrule allows the Zero to 90 connector to be secured to the conduit whilefully assembled. To install, simply loosen the tightening nut and screw onto conduit. A positiveliquid-tight seal is formed by the pressure sensitive internal gland as the nut is tightened. Thesealing ring assures a liquid-tight seal between the fitting and box.

Ferrule

Center Nutloosen to adjust angleSealing Ring forms liquid-tightseal between fitting and box

Locknut

InternalGland

TighteningNut

TM

Adjusts for ALL ANGLES...from 0° to 90°! To adjust the angle simply loosen the center nut, twist to the correct angle, and retighten.

R

R

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

DIMD

NMLT5090 06240 1/2 1/2 10 50 2.765 1.945 2.324 2.387NMLT7590 06260 3/4 3/4 10 50 3.540 2.590 3.250 2.820

Section_A_Liquid Tight 11/5/12 12:38 PM Page 4

Page 9: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

Liq

uid

Tig

ht

Arlington

www.aifittings.com Email: [email protected] Tel: (800) 233-4717 Fax: (570) 562-0646A-5

Straight Non-MetallicConnectorsFor use with non-metallic liquid-tight conduit, type B only.Produced from UV rated plasticfor long outdoor life.

Add suffix “BL” to Catalog # when ordering in black, for exampleNMLT50BL.

C

B

Screw-On 90° Non-MetallicConnectors For use with non-metallic liquid-tight conduit, type B only.Produced from UV rated plasticfor long outdoor life.

Add suffix “BL” to Catalog # when ordering in black, for example NMSC9050BL.

Add suffix “BL” to Catalog # when ordering in black, for example NMSC50BL.

A

C

BA

BA

Screw-On StraightNon-MetallicConnectorsFor use with non-metallic liquid-tight conduit, type B only.Produced from UV rated plasticfor long outdoor life.

E60812 LR49636

E60812 LR49636

E60812 LR49636

C

Conduit threads onto ferrule and up inside the outer body. The inside taper squeezes down on theoutside of conduit for a superior liquid-tight seal. The cut portion of the conduit does not show, giving amore attractive finished appearance. Also for use with flexible non-metallic tubing. These connectorsscrew on easily by hand and are removable with pliers.

Conduit threads onto ferrule and up inside the outer body. The inside taper squeezes down on the outside of conduitfor a superior liquid-tight seal. The cut portion of theconduit does not show, giving a more attractive finishedappearance. Also for use with flexible non-metallic tubing.These connectors screw on easily by hand and areremovable with pliers.

Note: Screw connector onto the conduit until it stops. If the fitting isnot in alignment with the knockout,you may unscrew the fitting up to one full turn for adjustment.

Installation InstructionsArlington’s reusable Liquid-Tight Fittings may be secured to conduit while fullyassembled because of our no-spin ferrule. Simply loosen nut, and screw ontoconduit. A positive liquid-tight seal is provided by our pressure sensitive internalgland when the nut is tightened. A liquid-tight seal is also assured between thefitting and box by a sealing ring.

R

R

R

R

R

R

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

NMSC38 21005 3/8 1/2 25 100 1.350 .535 1.241NMSC50 21000 1/2 1/2 25 100 1.440 .535 1.234NMSC75 21010 3/4 3/4 25 100 1.515 .535 1.520

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

NMSC9038 21003 3/8 1/2 25 100 2.100 .535 2.442NMSC9050 21007 1/2 1/2 25 100 2.100 .535 2.504NMSC9075 21009 3/4 3/4 25 100 2.455 .535 2.831

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

NMLT38 54380 3/8 1/2 25 100 1.425 .535 1.421NMLT50 54500 1/2 1/2 25 100 1.425 .535 1.421NMLT75 54750 3/4 3/4 10 50 1.475 .550 1.583NMLT100 54100 1 1 5 25 1.950 .670 1.925NMLT125 04223 1-1/4 1-1/4 5 25 2.217 .645 2.418NMLT150 04222 1-1/2 1-1/2 2 10 2.155 .660 2.700NMLT200 04221 2 2 2 10 2.400 .670 3.360

Section_A_Liquid Tight 11/5/12 12:38 PM Page 5

Page 10: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

Liq

uid

Tig

ht

Arlington

A-6Fax: (570) 562-0646 Tel: (800) 233-4717 Email: [email protected] www.aifittings.com

45° Non-MetallicConnectorsFor use with non-metallic liquid-tight conduit, type B only.45° connector provides asmooth, gradual radius bend.Wiring is easily pulled orpushed through fitting and thereare no sharp edges to stripwire. Produced from UV ratedplastic for long outdoor life.

Add suffix “BL” to Catalog # when ordering in black, for example NMLT4550BL.A

C

BE60812 LR49636

90° Non-MetallicConnectorsFor use with non-metallic liquid-tight conduit, type B only.90° connector provides asmooth, gradual radius bend.Wiring is easily pulled orpushed through fitting and thereare no sharp edges to stripwire. Produced from UV ratedplastic for long outdoor life.

Add suffix “BL” to Catalog # when ordering in black, for example NMLT9050BL.

C

AB

E60812 LR49636

R

R

R

R

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

NMLT4538 54538 3/8 1/2 10 50 1.550 .562 1.862NMLT4550 54550 1/2 1/2 10 50 1.596 .562 1.975NMLT4575 54575 3/4 3/4 10 50 1.820 .545 2.237NMLT45100 54110 1 1 5 25 2.200 .630 2.990NMLT45125 54125 1-1/4 1-1/4 5 25 2.710 .645 3.420NMLT45150 54150 1-1/2 1-1/2 2 10 2.960 .660 3.675NMLT45200 54200 2 2 2 10 3.500 .670 4.060

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

NMLT9038 54903 3/8 1/2 10 50 2.325 .562 2.440NMLT9050 54905 1/2 1/2 10 50 2.325 .562 2.440NMLT9075 54907 3/4 3/4 10 50 2.550 .545 2.840NMLT90100 54901 1 1 5 25 3.150 .630 3.922NMLT90125 54912 1-1/4 1-1/4 5 25 4.440 .645 4.650NMLT90150 54915 1-1/2 1-1/2 2 10 4.510 .660 4.810NMLT90200 54920 2 2 2 10 5.062 .670 5.320

Section_A_Liquid Tight 11/5/12 12:38 PM Page 6

Page 11: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

Liq

uid

Tig

ht

Arlington

www.aifittings.com Email: [email protected] Tel: (800) 233-4717 Fax: (570) 562-0646A-7

Straight Zinc Die-CastConnectorsFor use with metallic and non-metallic liquid-tight conduit, type B only.

LT50

LT250With Insulated Throat

C

B

A

C

B

A

LT50A

E60812 LR49636

E60812 LR49636

R

R

R

R

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

LT38 32380 3/8 1/2 25 100 1.440 .510 1.260LT50 32500 1/2 1/2 25 100 1.440 .520 1.385LT75 32750 3/4 3/4 10 50 1.562 .500 1.720LT100 32100 1 1 5 25 1.825 .593 1.900LT125 32125 1-1/4 1-1/4 5 25 2.068 .625 2.176LT150 32150 1-1/2 1-1/2 2 10 2.008 .625 2.507LT200 32200 2 2 2 10 2.103 .593 3.178LT250* 32250 2-1/2 2-1/2 1 1 3.269 .980 4.218LT300* 32300 3 3 1 1 4.060 1.070 4.919LT350* 32350 3-1/2 3-1/2 1 1 4.115 1.065 5.520LT400* 32400 4 4 1 1 4.323 1.139 5.948

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

LT38A 32381 3/8 1/2 25 100 1.533 .493 1.260LT50A 32501 1/2 1/2 25 100 1.593 .613 1.385LT75A 32751 3/4 3/4 10 50 1.656 .593 1.720LT100A 32101 1 1 5 25 1.935 .686 1.900LT125A 32121 1-1/4 1-1/4 5 25 2.168 .639 2.176LT150A 32151 1-1/2 1-1/2 2 10 2.101 .680 2.507LT200A 32201 2 2 2 10 2.196 .686 3.178LT250 32250 2-1/2 2-1/2 1 1 3.269 .980 4.218LT300 32300 3 3 1 1 4.060 1.070 4.919LT350 32350 3-1/2 3-1/2 1 1 4.115 1.065 5.520LT400 32400 4 4 1 1 4.323 1.139 5.948

*Provided with insulated throat.

Section_A_Liquid Tight 11/5/12 12:38 PM Page 7

Page 12: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

Liq

uid

Tig

ht

Arlington

A-8Fax: (570) 562-0646 Tel: (800) 233-4717 Email: [email protected] www.aifittings.com

B

C

90° Zinc Die-CastConnectorsFor use with metallic and non-metallic liquid-tight conduit, type B only.

*Provided with insulated throat.

LT9050

LT90150

A

LT9050A

LT90150A

C

BA

With Insulated Throat

E60812 LR49636

E60812 LR49636

R

R

R

R

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

LT9038 32938 3/8 1/2 10 50 2.062 .520 2.340LT9050 32950 1/2 1/2 10 50 2.128 .525 2.312LT9075 32970 3/4 3/4 10 50 2.515 .510 2.664LT90100 32910 1 1 5 25 2.758 .675 3.640LT90125 32913 1-1/4 1-1/4 2 10 3.362 .700 3.912LT90150 32915 1-1/2 1-1/2 2 10 3.500 .604 4.368LT90200 32920 2 2 2 10 4.106 .680 4.865LT90250* 32925 2-1/2 2-1/2 1 1 5.500 .870 6.225LT90300* 32930 3 3 1 1 6.000 .950 6.720LT90350* 32935 3-1/2 3-1/2 1 1 6.625 .950 7.450LT90400* 32940 4 4 1 1 7.000 .950 8.000

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

LT9038A 32931 3/8 1/2 10 50 2.137 .520 2.340LT9050A 32951 1/2 1/2 10 50 2.203 .525 2.312LT9075A 32971 3/4 3/4 10 50 2.590 .510 2.664LT90100A 32911 1 1 5 25 2.906 .675 3.640LT90125A 32912 1-1/4 1-1/4 2 10 3.473 .700 3.912LT90150A 32955 1-1/2 1-1/2 2 10 3.575 .604 4.368LT90200A 32921 2 2 2 10 4.206 .680 4.865LT90250 32925 2-1/2 2-1/2 1 1 5.000 .945 6.225LT90300 32930 3 3 1 1 6.000 1.025 6.720LT90350 32935 3-1/2 3-1/2 1 1 6.625 1.025 7.450LT90400 32940 4 4 1 1 7.000 1.025 8.000

Section_A_Liquid Tight 11/5/12 12:38 PM Page 8

Page 13: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

EM

T

Arlington

www.aifittings.com Email: [email protected] Tel: (800) 233-4717 Fax: (570) 562-0646B-1

Insulating BushingsPress fit. Holds firmly in placewhile pulling cables.

Refer to page I-1 for Rigid Insulating Bushings size 1/2" through 4".*Can also be used for rigid, IMC, and PVC rigid conduit.

Arlington’s EMT Insulating Bushings protect cables from abrasion by EMT. Examples:Power, Cable TV, computer datalines, telephone/modem, audio/video cables, alarmsystems, security systems. EMT is often used to protect cables where damage couldoccur in a house or building.

E105706 LR49636

Meets 2011 NEC coderequirements for 300-15(c)protection. Listed for use inenvironmental air handlingspaces per 2011 NEC coderequirements 300-22(c).

B

Example: Telephone cableprotected byEMT insulatingbushing.

EMT 2-PieceConnectorZinc die-cast.

A

B

E20643 LR49636

R

R

Place board over EMTbushing and tap onto Rigid or EMT with hammer.

Non-metallic sheathed cable

Arlington's EMT insulating bushing

Non-structural ceiling

Surface mountedpanel or box

EMT

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

UNITPKG

STDPKG

DIMA

DIMB

EMT50 12200 1/2 100 100 .531 .840EMT75 12205 3/4 100 100 .531 1.056EMT100 12220 1 100 100 .625 1.280EMT125 12225 1-1/4 100 100 .625 1.660EMT150 12230 1-1/2 100 100 .625 1.915EMT200 12235 2 50 50 .625 2.377EMT250* 12240 2-1/2 25 25 1.225 3.062EMT300* 12245 3 25 25 1.225 3.690EMT350* 12250 3-1/2 25 25 1.231 4.187EMT400* 12255 4 25 25 1.233 4.815

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

L20 32000 1/2 1/2 50 250 .770 1.107

A

Section_B_EMT 11/13/12 11:35 AM Page 1

Page 14: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

EM

T

Arlington

B-2Fax: (570) 562-0646 Tel: (800) 233-4717 Email: [email protected] www.aifittings.com

Conduit CapsConduit cap and insulatingbushing.

Refer to page I-1 for Rigid Insulating Bushings size 1/2"through 4".*Can also be used for rigid, IMC, and PVC rigid conduit.

A

B

EMT50C

EMT75C

Use this capped version to seal off conduit during concrete pours. Then removecap/seal with razor knife or use screwdriver to punch hole in cap. (EMT300C)

String canbe used to aidremoval.

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

UNITPKG

STDPKG

DIMA

DIMB

EMT50C 12203 1/2 100 100 .531 .840EMT75C 12204 3/4 100 100 .531 1.056EMT100C 12207 1 100 100 .625 1.280EMT125C 12209 1-1/4 100 100 .625 1.660EMT150C 12211 1-1/2 100 100 .625 1.915EMT200C 12213 2 50 50 .625 2.377EMT250C* 12215 2-1/2 25 25 1.225 3.062EMT300C* 12217 3 25 25 1.225 3.690EMT350C* 12219 3-1/2 25 25 1.231 4.187EMT400C* 12221 4 25 25 1.233 4.815

Zinc CombinationCouplings EMT to RigidEMT compression to screw-inrigid metal conduit. Zinc die-cast.

B

A C

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

2400 06920 1/2” 50 50 1.000 1.267 .9462410 06921 3/4” 50 50 1.000 1.412 1.2002411 06922 3/4” 50 50 1.210 1.475 1.200

2400

Use with any listed fitting.

Section_B_EMT 11/13/12 11:35 AM Page 2

Page 15: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

EM

T

Arlington

www.aifittings.com Email: [email protected] Tel: (800) 233-4717 Fax: (570) 562-0646B-3

Add suffix “RH” for Robertson Head Screws.*Concrete tight when taped.†Listed for use with steel and aluminum EMT, IMC, and rigid conduit.

EMT Set-ScrewConnectorsConcrete tight. Zinc die-cast.

∆Add suffix “RH” for Robertson Head Screws.*Concrete tight when taped. †Listed for use with steel and aluminum EMT, IMC, and rigid conduit.

800

803

AB

C

E20643 LR49636

EMT Set-Screw Connectors withInsulated ThroatConcrete tight. Zinc die-cast.

800A

803A

E20643 LR49636

AB

C

R

R

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TradeSize

KOSize

UNITPKG

STDPKG

DIMA

DIMB

DIMC

800∆ 00800 1/2 1/2 50 500 1.143 .375 1.076801∆ 00801 3/4 3/4 25 250 1.390 .350 1.300802∆ 00802 1 1 20 200 1.550 .460 1.550803 00803 1-1/4 1-1/4 10 60 1.930 .636 1.935804* 00804 1-1/2 1-1/2 10 60 2.200 .707 2.175805* 00805 2 2 5 30 2.535 .750 2.650806*† 00806 2-1/2 2-1/2 12 12 2.930 .830 3.300807*† 00807 3 3 12 12 3.330 .930 3.9108075*† 08075 3-1/2 3-1/2 6 6 3.500 1.000 4.465808*† 00808 4 4 6 6 3.665 1.000 4.984

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TradeSize

KOSize

UNITPKG

STDPKG

DIMA

DIMB

DIMC

800A 80010 1/2 1/2 50 500 1.240 .470 1.076801A 80110 3/4 3/4 25 250 1.483 .449 1.300802A 80210 1 1 20 200 1.643 .550 1.550803A 80310 1-1/4 1-1/4 10 60 2.023 .729 1.935804A* 80410 1-1/2 1-1/2 10 60 2.293 .800 2.195805A* 80510 2 2 5 30 2.630 .840 2.650806A*† 80610 2-1/2 2-1/2 12 12 3.030 .920 3.280807A*† 80710 3 3 12 12 3.468 1.030 3.9108075A*† 80711 3-1/2 3-1/2 6 6 3.600 1.088 4.465808A*† 80810 4 4 6 6 3.758 1.100 4.984

Section_B_EMT 11/13/12 11:35 AM Page 3

Page 16: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

EM

T

Arlington

B-4Fax: (570) 562-0646 Tel: (800) 233-4717 Email: [email protected] www.aifittings.com

EMT Set-ScrewCouplingsConcrete tight. Zinc die-cast.

*Add suffix “RH” for Robertson Head Screws.†Listed for use with steel and aluminum EMT, IMC, and rigid conduit.

810

816

A

B

E20643 LR49636

EMT CompressionCouplingsUL listed concrete tight. CSAlisted concrete tight/rain tight. Zinc die-cast.

830

836B

AE20643 LR49636

R

R

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TradeSize

UNITPKG

STDPKG

DIMA

DIMB

810* 00810 1/2 50 500 .950 1.560811* 00811 3/4 25 250 1.145 1.869812* 00812 1 15 150 1.435 2.000813 00813 1-1/4 20 120 1.828 2.500814 00814 1-1/2 10 60 2.075 2.890815 00815 2 5 30 2.535 2.567816† 00816 2-1/2 12 12 3.280 4.000817† 00817 3 12 12 3.910 4.5008175† 08175 3-1/2 6 6 4.460 4.814818† 00818 4 6 6 4.984 5.269

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TradeSize

UNITPKG

STDPKG

DIMA

DIMB

830 00830 1/2 50 500 1.550 1.080831 00831 3/4 25 250 1.615 1.313832 00832 1 15 150 1.692 1.616833 00833 1-1/4 10 100 2.160 2.080834 00834 1-1/2 10 60 2.290 2.380835 00835 2 10 60 2.600 2.910836 00836 2-1/2 12 12 3.070 3.470837 00837 3 12 12 3.300 4.133838 00838 3-1/2 6 6 3.330 4.775839 00839 4 6 6 3.445 5.300

Section_B_EMT 11/13/12 11:35 AM Page 4

Page 17: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

EM

T

Arlington

www.aifittings.com Email: [email protected] Tel: (800) 233-4717 Fax: (570) 562-0646B-5

EMT CompressionConnectorsUL listed concrete tight. CSAlisted concrete tight/rain tight. Zinc die-cast.

*Listed for use with steel and aluminum EMT, IMC, and rigid conduit.

820

826

B

EMT CompressionConnectors withInsulated ThroatUL listed concrete tight. CSAlisted concrete tight/rain tight. Zinc die-cast.

*Listed for use with steel and aluminum EMT, IMC, and rigid conduit.

820A

826A

C

B

A

E20643 LR49636

E20643 LR49636

C

A

R

R

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TradeSize

KOSize

UNITPKG

STDPKG

DIMA

DIMB

DIMC

820 00820 1/2 1/2 50 500 1.235 .349 1.080821 00821 3/4 3/4 25 250 1.350 .453 1.313822 00822 1 1 15 60 1.525 .538 1.616823 00823 1-1/4 1-1/4 5 25 1.878 .600 2.080824 00824 1-1/2 1-1/2 10 100 2.020 .607 2.380825 00825 2 2 10 60 1.995 .645 2.910826* 00826 2-1/2 2-1/2 12 12 2.775 .860 3.470827* 00827 3 3 12 12 2.847 .998 4.133828* 00828 3-1/2 3-1/2 6 6 2.800 .998 4.775829* 00829 4 4 6 6 3.000 1.007 5.300

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TradeSize

KOSize

UNITPKG

STDPKG

DIMA

DIMB

DIMC

820A 82010 1/2 1/2 50 500 1.346 .442 1.080821A 82110 3/4 3/4 25 250 1.443 .546 1.313822A 82210 1 1 15 60 1.620 .631 1.616823A 82310 1-1/4 1-1/4 5 25 1.971 .693 2.080824A 82410 1-1/2 1-1/2 10 100 2.120 .700 2.380825A 82510 2 2 10 60 2.088 .738 2.910826A* 82610 2-1/2 2-1/2 12 12 2.870 .953 3.470827A* 82710 3 3 12 12 2.940 1.091 4.133828A* 82810 3-1/2 3-1/2 6 6 2.900 1.091 4.775829A* 82910 4 4 6 6 3.150 1.100 5.300

Section_B_EMT 11/13/12 11:35 AM Page 5

Page 18: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

EM

T

Arlington

B-6Fax: (570) 562-0646 Tel: (800) 233-4717 Email: [email protected] www.aifittings.com

CombinationCouplingsEMT to Flex. Zinc die-cast.

*CSA only. A

BE60812 LR49636

CombinationCouplingsEMT set-screw to Flex. Zincdie-cast.

8610

8610-86308600

8600

A

B

E60812 LR49636

B

R

R

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

EMTSize

FlexSize

UNITPKG

STDPKG

DIMA

DIMB

CABLERANGE

860* 00860 1/2 3/8 50 500 1.300 1.156 .530 - .620861 00861 1/2 1/2 25 250 1.645 1.363 .850 - .910862 00862 3/4 3/4 25 100 1.975 1.553 1.100 - 1.100

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

EMTSize

FlexSize

UNITPKG

STDPKG

DIMA

DIMB

CABLERANGE

8600* 08600 1/2 3/8 50 500 1.162 1.090 .530 - .6208610 08610 1/2 1/2 50 500 1.736 1.170 .850 - .9108620 08620 3/4 3/4 25 100 1.934 1.360 1.100 - 1.1008630 08630 1 1 10 40 2.290 1.625 1.255 - 1.375

*CSA only.A

B

EMT Rain TightCompressionCouplingsUL listed rain tight and concretetight. Steel. Blue compressionnuts help identify theseproducts as raintight.

A

E200730

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TradeSize

UNITPKG

STDPKG

DIMA

DIMB

830RT 82030 1/2 50 50 1.890 1.125831RT 82031 3/4 50 50 2.052 1.375832RT 82032 1 25 25 2.219 1.688833RT 82033 1-1/4 10 10 2.558 2.063834RT 82034 1-1/2 10 10 2.587 2.250835RT 82035 2 10 10 2.746 2.750836RT 83035 2-1/2 12 12 4.207 3.625837RT 83006 3 12 12 4.500 4.250838RT 83007 3-1/2 6 6 5.025 4.688839RT 83008 4 6 6 5.460 5.188

Section_B_EMT 11/13/12 11:35 AM Page 6

Page 19: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

EM

T

Arlington

www.aifittings.com Email: [email protected] Tel: (800) 233-4717 Fax: (570) 562-0646B-7

EMT Rain TightCompressionConnectors UL listed rain tight andconcrete tight. Steel. Bluecompression nuts help identifythese products as raintight.

C

BA

EMT Rain TightCompressionConnectors withInsulated ThroatUL listed rain tight andconcrete tight. Steel. Bluecompression nuts help identifythese products as raintight.

E200730

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TradeSize

KOSize

UNITPKG

STDPKG

DIMA

DIMB

DIMC

820RT 82020 1/2 1/2 50 50 1.608 .437 1.125821RT 82021 3/4 3/4 50 50 1.657 .437 1.375822RT 82022 1 1 25 25 1.823 .500 1.688823RT 82023 1-1/4 1-1/4 10 10 2.103 .625 2.063824RT 82024 1-1/2 1-1/2 10 10 2.191 .625 2.250825RT 82025 2 2 10 10 2.298 .688 2.750826RT 83005 2-1/2 2-1/2 12 12 3.548 .750 3.625827RT 83006 3 3 12 12 3.628 .875 4.250828RT 83007 3-1/2 3-1/2 6 6 3.834 .937 4.688829RT 83008 4 4 6 6 4.135 .937 5.188

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TradeSize

KOSize

UNITPKG

STDPKG

DIMA

DIMB

DIMC

820ART 82045 1/2 1/2 50 50 1.670 .500 1.125821ART 82046 3/4 3/4 50 50 1.719 .500 1.375822ART 82047 1 1 25 25 1.885 .563 1.688823ART 82048 1-1/4 1-1/4 10 10 2.166 .688 2.063824ART 82049 1-1/2 1-1/2 10 10 2.253 .688 2.250825ART 82050 2 2 10 10 2.360 .750 2.750826ART 83000 2-1/2 2-1/2 12 12 3.610 .813 3.625827ART 83001 3 3 12 12 3.690 .938 4.250828ART 83002 3-1/2 3-1/2 6 6 3.896 1.000 4.688829ART 83003 4 4 6 6 4.197 1.000 5.188

CombinationCouplingsEMT compression to screw-inflexible metal conduit. Zincdie-cast.

B

A

CD

E60812 LR49636

R

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

EMTSize

FlexSize

UNITPKG

STDPKG

DIMA

DIMB

DIMC

DIMD

GF860 76860 1/2 3/8 25 100 1.504 .445 .725 1.060GF861 76861 1/2 1/2 25 250 1.345 .715 .725 1.060GF862 76862 3/4 3/4 25 250 1.745 .946 .950 1.305GF863 80173 1 1 25 100 1.895 1.125 1.170 1.625GF864 80175 1-1/4 1-1/4 10 40 2.500 1.420 1.340 2.100

C

BA

E200730

Section_B_EMT 11/13/12 11:36 AM Page 7

Page 20: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

EM

T

Arlington

B-8Fax: (570) 562-0646 Tel: (800) 233-4717 Email: [email protected] www.aifittings.com

CombinationThreaded Rigidand Set-Screw EMT90° pulling elbows with coverand gasket. Zinc die-cast.

See hub illustration below.

See hub illustration below.

Arlington’s combination hubs arethreaded for rigid and include set-screws for EMT. The set-screwsmay be used for rigid, but are notnecessary. They are listed raintight with rigid and concrete tightwhen taped for EMT. Theseproducts can also be used forEMT to rigid.

Hub IllustrationFor Combination Threaded and Set-Screw Pull Elbows

CombinationThreaded Rigidand Set-ScrewEMT To Box90° pulling elbows with coverand gasket. Zinc die-cast.

A

B

B

A

E20643 LR49636

E20643 LR49636

R

R

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TradeSize

UNITPKG

STDPKG

DIMA

DIMB

HL5000 83105 1/2 10 100 2.150 2.150HL7500 83175 3/4 5 50 2.300 2.300HL100 50171 1 5 25 3.040 3.040HL125 50173 1-1/4 2 10 3.900 3.900

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TradeSize

UNITPKG

STDPKG

DIMA

DIMB

9100 91005 1/2 5 50 2.030 1.9459110 91100 3/4 5 50 2.260 2.1409120 50165 1 5 25 2.610 2.6109130 50167 1-1/4 2 10 3.037 3.037

Section_B_EMT 11/13/12 11:36 AM Page 8

Page 21: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

EM

T

Arlington

www.aifittings.com Email: [email protected] Tel: (800) 233-4717 Fax: (570) 562-0646B-9

Heavy-Duty1-Hole EMT StrapsPlated steel, Click-on.

E186443 LR104691

A

B

D

C

HOLESIZE

2-Hole EMT StrapsPlated steel, Click-on.

A

B

D

C

HOLE SIZE

R

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

EMTSize

UNITPKG

STDPKG

DIMA

DIMB

DIMC

DIMD

370 00370 1/2 100 1000 1.700 .700 .562 .250371 00371 3/4 100 1000 1.935 .975 .625 .250372 00372 1 50 500 2.210 2.210 .750 .312373 00373 1-1/4 25 250 2.800 2.800 .875 .375374 00374 1-1/2 25 100 3.140 3.140 1.000 .375375 00375 2 25 100 3.890 3.890 1.125 .437346 00346 2-1/2 25 25 4.927 4.927 1.250 .562347 00347 3 25 25 5.560 5.560 1.250 .562348 00348 3-1/2 10 10 6.337 6.337 1.250 .562349 00349 4 10 10 6.811 6.811 1.250 .562

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

EMTSize

UNITPKG

STDPKG

DIMA

DIMB

DIMC

DIMD

360 00360 1/2 100 1000 2.200 .790 .562 .187361 00361 3/4 50 500 2.700 .980 .625 .187362 00362 1 50 250 2.975 1.185 .688 .187363 00363 1-1/4 50 250 3.650 1.535 .750 .253364 00364 1-1/2 25 250 4.250 1.670 .875 .253365 00365 2 25 250 4.775 2.300 1.000 .375356 00356 2-1/2 25 100 5.850 2.855 1.000 .375357 00357 3 25 25 6.460 3.425 1.000 .375358 00358 3-1/2 10 10 7.300 3.925 1.000 .375359 00359 4 10 10 7.895 4.390 1.000 .375

Section_B_EMT 11/13/12 11:36 AM Page 9

Page 22: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

NM

Ca

ble

Arlington

www.aifittings.com Email: [email protected] Tel: (800) 233-4717 Fax: (570) 562-0646C-1

CABLEWAY™ CableRunway SupportSystemCable support system for eitherpower or low voltage cable. For new construction or retrofit. Non-metallic.

Features and Benefits• Secure, UL Listed as a cable support system

• For power or low voltage cable• Support brackets attach directly to framing members, without structural damage

• Time saving system – no holes to drill through joists

• Brackets hold cables in place – open the bracket for easier cable insertion

• Slide-on trough protects and covers cable

• Install additional trough sections as needed and join them together with couplings

• Push-on end caps complete the job

T23C

T23F

T23W

T205

T23C

T23E

T23H

T205

B

C

A

B

C

D

D D

A

B

C

A

D

B

C

A

Rated for a maximum load of 6 lbs/linear foot of runway.

E161207 LR49636

R

R

T23A

T23T

T23H

T23E

B

C A

T23T

T23F

T23A

T23WAB

C

D

A

B

D

C B

DA

C

NM Cable w/ CopperConductors

Fill Units PerCable

(or) Total Cables ofOne Size

14/2 1 ea. 4014/3 1.25 ea. 3214/4 1.5 ea. 2612/2 1.5 ea. 2612/3 1.75 ea. 2212/4 2 ea. 2010/2 2 ea. 2010/3 2.25 ea. 178/2 2.25 ea. 178/3 2.50 ea. 166/2 2.75 ea. 146/3 3 ea. 13

Wire Fill Chart | Maximum Fill: 40 Units

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

DESCRIPTIONSTDPKG

DIMA

DIMB

DIMC

DIMD

T205 38060 Wire Tray-5 ft. Lengths 10 4.150 2.000 3.380 60.000T23A 38065 Angle 10 4.160 2.000 3.380 9.280T23C 38061 Coupling 10 4.630 2.380 3.570 2.000T23E 38062 End Cap 10 4.570 2.190 3.570 .760T23F 38066 Flat Surface Bracket 25 5.750 2.850 3.600 2.190T23H 38063 Support Bracket 25 5.500 3.880 3.620 1.500T23T 38067 Tee 10 4.160 2.000 3.380 9.280T23W 38068 Wall Mount Bracket 10 2.410 5.240 5.970 5.240

(19)14/2 @1 = 19 Units(8)12/2 @1.5 = 12 Units(4)10/3 @2.25 = 9 Units

total = 40 Units

Example:

Scan For Video

Section_C_NM Cable 11/13/12 12:07 PM Page 1

Page 23: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

NM

Ca

ble

Arlington

C-2Fax: (570) 562-0646 Tel: (800) 233-4717 Email: [email protected] www.aifittings.com

Refer to pages C-13 and C-14 for complete cable ranges.SNAP-TITE® products have been tested and listed by UL in accordance with UL’sground fault requirements. For additional information see page 6.

SNAP-TITE®

ConnectorsWith spring steel clip. For NM •SE • MCI • MCIA • Flex • ACcable. For steel and aluminum jacketed cables. Zinc die-cast.

NM CableConnectorFor NM cable. Zinc die-cast.

Refer to pages C-13 and C-14 for complete cable ranges.SNAP-TITE® products have been tested and listed by UL in accordance with UL’sground fault requirements. For additional information see page 6.For connectors that cost less and install faster see page C-8.

E28474 LR49636

Refer to pages C-13 and C-14 for complete cable ranges.For connectors that cost less and install faster see page C-8.

840ST 8400ST

840ST

8400ST

SNAP-TITE®

ConnectorWith spring steel clip. For NMcable. Zinc die-cast.

A

C

B

A

B

C

A

B

C

E28474 LR49636

R

R

R

R

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

CABLERANGE

840ST 8 0070 3/8 1/2 100 1000 .485 .879 .858 .225 - .6128400ST 80074 3/8 1/2 100 1000 .485 .879 .858 .225 - .612

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

CABLERANGE

841 00841 3/8 1/2 100 1000 .422 .825 1.105 .225 - .612

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

CABLERANGE

841ST 80068 3/8 1/2 100 1000 .510 .912 .920 .225 - .612

E28474 LR49636

R

R

Section_C_NM Cable 11/13/12 12:07 PM Page 2

Page 24: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

NM

Ca

ble

Arlington

www.aifittings.com Email: [email protected] Tel: (800) 233-4717 Fax: (570) 562-0646C-3

SNAP-TITE®

ConnectorWith spring steel clip.For NM • SE cable. Zinc die-cast. SNAP-TITE® products have been tested and listed by UL in accordance with UL’s

ground fault requirements. For additional informationsee page 6.

E28474 LR49636

Refer to pages C-13 and C-14 for complete cable ranges.*Listed for MCI only. UL# E123751.†For connectors that cost less and install faster see page C-8.

8400

Cable ConnectorsFor NM • SE • MCI • MCIA •AC cable. For steel andaluminum jacketed cables.Zinc die-cast.

840

8400

8401

E28474 LR49636

840

84028401

A

C

B

A

C

B

CombinationCouplingEMT to NM. Zinc die-cast.

E60812 LR49636

A

B

R

R

R

R

R

R

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

CABLERANGE

840* 00840 3/8 1/2 100 1000 .422 .825 1.105 .225 - .6128400* 08400 3/8 1/2 100 1000 .422 .825 1.105 .225 - .6128401* 08401 3/8 1/2 100 1000 .422 .825 1.105 .225 - .612 8402 08402 3/4 3/4 50 500 .533 1.093 1.395 .375 - .780

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

CABLERANGE

842ST 8 0084 3/4 3/4 50 500 .510 1.070 1.200 .300 - .780

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

UNITPKG

STDPKG

DIMA

DIMB

CABLERANGE

8600 08600 1/2 50 500 1.162 1.090 .250 - .612

Section_C_NM Cable 11/13/12 12:07 PM Page 3

Page 25: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

NM

Ca

ble

Arlington

C-4Fax: (570) 562-0646 Tel: (800) 233-4717 Email: [email protected] www.aifittings.com

Cable ConnectorsFor NM • SE cable. Zinc die-cast.

Cable ConnectorsFor NM • SEU cable. Zinc die-cast.

*UL# E66990 - Service entrance ONLY.

E28474 LR49636

E28474 LR49636

A

C

B

A

C

B

R

R

R

R

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

MAXOPENING

842 00842 3/4 3/4 50 500 .481 1.000 1.375 .730843 00843 1 1 25 250 .780 1.284 1.670 .850844 00844 1-1/4 1-1/4 10 100 .710 1.312 2.030 .900848* 00848 1-1/2 1-1/2 10 50 .817 1.453 2.300 .960849* 00849 2 2 10 50 .823 1.590 2.900 .960

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

MAXOPENING

842 00842 3/4 3/4 50 500 .481 1.000 1.375 .730843S 84310 1 1 25 250 .780 1.284 1.670 .970844S 84410 1-1/4 1-1/4 10 100 .710 1.312 2.030 1.160848S 84810 1-1/2 1-1/2 10 50 .817 1.453 2.300 1.420849S 84910 2 2 10 50 .823 1.590 2.900 1.750

E28474

NM CableConnectorsPlated steel.

*UL only.Refer to pages C-12 and C-13 for complete cable ranges.

A B

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

UNITPKG

STDPKG

DIMA

DIMB

MAXOPENING

BT50* 24050 14/2 - 8-3 100 1000 1.500 .720 .250 - .600BT75* 24075 8/2 - 6/2 50 500 1.764 .811 .124 - .934BT125 24125 2/0 - 3/0 25 250 2.245 .842 .275 - .900BT150 24150 4/0 20 200 2.705 .835 .275 - .900

Section_C_NM Cable 11/13/12 12:07 PM Page 4

Page 26: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

NM

Ca

ble

Arlington

www.aifittings.com Email: [email protected] Tel: (800) 233-4717 Fax: (570) 562-0646C-5

Gland-Type ServiceEntrance CableConnectorsTwin screw type. Zinc die-cast.

E66990 LR49636

AB

C

D

Low profile design to fit the new smaller UF cables as well as standard sizes.

UF ConnectorsCompression type for underground feeder cable.Zinc die-cast.

E28474 LR49636

A

B

C

OPENING

ZINCLOCKNUT

POLYETHYLENESEALING RING

ZINCBODY

NYLONGRIPPER

SANTOPRENE®

GROMMET

ZINCNUT

Non-Metallic UF ConnectorsCompression type for underground feeder cable.

Low profile design to fit the new smaller UF cables as well as standard sizes.

E28474 LR49636

C

B

A

ZINCLOCKNUT

POLYETHYLENESEALING RING

NYLONBODY

NYLONGRIPPER

SANTOPRENE®

GROMMET

NYLONNUT

R

R

R

R

R

R

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

DIMD

CABLERANGE

WC1001 53101 1 1 1 50 1.400 .615 1.500 2.230 .630 x 1.000

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

CABLERANGE

UF50 36500 1/2 1/2 25 100 1.792 .630 1.042 14/2 - 12/2UF75 51302 3/4 3/4 10 50 1.792 .630 1.042 14/3 - 10/2

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

CABLERANGE

NMUF50 55040 1/2 1/2 25 100 1.792 .630 1.042 14/2 - 12/2NMUF75 54367 3/4 3/4 10 50 1.792 .630 1.042 14/3 - 10/2

Section_C_NM Cable 11/13/12 12:07 PM Page 5

Page 27: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

NM

Ca

ble

Arlington

C-6Fax: (570) 562-0646 Tel: (800) 233-4717 Email: [email protected] www.aifittings.com

D HOLE SIZE

1-Hole AluminumStrapsFor service entrance cable.Aluminum.

A

B

C

1-Hole Steel StrapsFor service entrance cable.Plated steel.

A

B

D HOLE SIZE

C

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

WIRESIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

DIMD

3232 32320 3 # 8 to 3 #4 100 1000 2.078 .775 .600 .2653282 03282 3 #1/0 to 3 #2/0 100 1000 2.488 .940 .720 .2653284 32840 3 #3/0 to 3 #4/0 100 1000 2.710 1.218 1.00 .325

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

WIRESIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

DIMD

301 00301 8/3 - 3/3 100 1000 1.637 .442 .565 .265303 00303 2/3 100 1000 1.830 .530 .575 .265313S 00133 1, 1/0 or 2/0 100 1000 2.472 .770 1.000 .325314S 00014 3/0, 4/0 100 1000 2.790 .920 1.000 .330

2-Hole Cable StrapsFor SEU cable. Plated steel.

AB

C

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

WIRESIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

C STRAP 37500 8/3-3/3 50 200 2.410 .750 .470E STRAP 43625 2/3 50 200 1.080 .750 .575H STRAP 82990 1/0-2/0 50 200 3.183 .755 .750K STRAP 83770 3/0, 4/0 50 200 3.500 .755 .890

Section_C_NM Cable 11/13/12 12:07 PM Page 6

Page 28: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

NM

Ca

ble

Arlington

www.aifittings.com Email: [email protected] Tel: (800) 233-4717 Fax: (570) 562-0646C-7

Non-Metallic Push-In ConnectorsFor NM and flexible cord.

Refer to pages C-13 and C-14 for complete cableranges.

NM841

E28474 LR49636

NM840

1. Disconnect electrical power.Push the connector into knockout.

2. Install required cables or cords.3. Place wedge in connectorslot and lock tight with a pairof pliers. Tightened wedgeprovides strong, positive grip.

AB

C

1

3

2

Non-Metallic Cable ConnectorsFor non-metallic sheathedcable. One piece construction.Listed for 1 or 2 cables. Holdscables securely and handles awide range of cable sizes.

E28474 LR49636 B

A

C

Refer to pages C-12 and C-13 for complete cable ranges.

R

R

R

R

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

NM840 54840 3/8 1/2 100 1000 1.031 .375 .965NM841 54841 1/2 1/2 50 500 1.340 .475 1.125NM842 54842 3/4 3/4 25 250 1.510 .475 1.200NM843 54843 1 1 25 250 1.637 .475 1.500NM844 50175 1-1/4 1-1/4 10 100 2.085 .475 2.012

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

NM74 54510 3/8 1/2 100 1000 1.289 1.029 .875NM75 54513 3/4 3/4 25 250 1.289 1.271 1.117

Installation Instructions

Section_C_NM Cable 11/13/12 12:07 PM Page 7

Page 29: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

NM

Ca

ble

Arlington

C-8Fax: (570) 562-0646 Tel: (800) 233-4717 Email: [email protected] www.aifittings.com

Refer to pages C-13 and C-14 for complete cable ranges.

Black Button™Non-Metallic Push-In ConnectorsFor NM cable.

E28474 LR49636

The Black Button is not only the lowest cost NM connectoron the market, but offers thefastest method of installingsingle or multiple cables.

For multiple cable installations:• Two cables may be insertedtogether or individually.• A second cable may beadded without removing thefirst.

Plus, the NM94 meets UL andCSA requirements for single ormultiple cables.

1. Disconnect electrical power. Insert connector into knockout.

2. Push non-metallic sheathedcable into the connector todesired length.

RemovalIf necessary, the NM94 seriesmay be removed with ascrewdriver. 1. Slip screwdriver under NM connector and twist.

2. NM94 pops out of the knockout.

Reduce your Labor Costs!

• Listed for both 1 or 2 cables.• Installs easily... snaps into KO using light finger pressure.• Cables insert without a struggle for a smooth installation.• Holds wires securely - meets and exceeds UL pullout tests.• Simple to remove with a twist of a screwdriver.• Arlington’s Black Button™ is the lowest cost NM cable connector available today.

A

BC

1 2

1 2

NM94

NM95

NM96

R

R

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

KOSIZE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

NM94 05488 3/8 1/2 250 1000 1.010 .450 .096NM940 72156 3/8 1/2 100 1000 1.010 .450 .096NM95 10956 3/4 3/4 50 500 1.293 .597 .096NM96 72158 1 1 25 250 1.648 .683 .156

Installation Instructions

Section_C_NM Cable 11/13/12 12:07 PM Page 8

Page 30: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

NM

Ca

ble

Arlington

www.aifittings.com Email: [email protected] Tel: (800) 233-4717 Fax: (570) 562-0646C-9

E161207 LR49636

Non-MetallicBushings for MetalStuds

These bushings fit existing irregular shaped holes in metal studs, alleviating the needto punch holes in metal studs, weakening the structural member. Use these bushingsto comply with paragraph 300-4(b)(1) of the 2011 NEC code which states that: “In bothexposed and concealed locations where nonmetallic-sheathed cables pass througheither factory or field punched, cut, or drilled slots or holes in metal members, thecable shall be protected by bushings or grommets covering all metal edges andsecurely fastened in the opening prior to installation of the cable.”

Common hole configurations in metal studs.

CODE VIOLATION

SHARP EDGENM CABLE

To install these bushings in an irregular shapedhole, pass one end of the joined connectorthrough the hole in the stud. Snap the bushingand the washer ends together. There’s no needto separate the two halves.If a punched hole is required, the SB13 can beinstalled in a standard 1" trade size, roundpunched hole (1-3/8" diameter). Snap thebushing end into the hole.

1 2

3

A

B

C

WASHER BUSHING

FITS A

STANDARD 1

"

KNOCKOUT

D

Note: See page R-10 for larger sizes.

Non-MetallicBushings for Metal Studs

E161207 LR49636

A

C

B

R

R

R

R

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

STDPKG

DIMA

DIMB

DIMC

SB1 18001 1/2 1000 .940 .470 .700SB10 18010 1/2 100 .940 .470 .700SB3 18050 1 1000 1.750 .400 1.150SB30 18053 1 100 1.750 .400 1.150

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

UNITPKG

STDPKG

DIMA

DIMB

DIMC

SB13 40115 500 5.670 2.500 .505 1.300SB130 40130 100 5.670 2.500 .505 1.300

Installation Instructions

Section_C_NM Cable 11/13/12 12:08 PM Page 9

Page 31: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

NM

Ca

ble

Arlington

C-10Fax: (570) 562-0646 Tel: (800) 233-4717 Email: [email protected] www.aifittings.com

CS6 Cable Standoff

E161207 LR49636

E161207 LR49636

Note: For position only. For support clips for AC/MC cable seeNM310 on page E-22.

Metal Stud Wood Stud

Alternate fasteningoption: Use staple

Simply position the CS6 in the desiredlocation and insert a sheet metal screwinto a steel or wood stud or use a nailin a wood stud. Cable or cables canthen be placed between serrated forks.Install mating washer over serratedforks to secure cable/cables.

CS7 Holds...• Up to five runs of 12/2 non-metallic sheathed cable.• Up to eight runs of Cat 5 cable.• Up to four runs of Cat 6 cable.• Up to five runs of coaxial cable.

CS4 Holds...• One 14/3 to one 10/3• Three 14/2 W/G to three 10/3

Cable StandoffsPositions non-metallicsheathed cable, phone/datacable, and coaxial cable. Installs with a screw or nail.Nail included with CS4. *UL and CSA only

Note: For position only.

A

B

C

A

B

C

A

B

C

Holds...Six 14/2 NM cables orFive 12/2 NM cables orFour 10/2 NM cables orOne 14/2 to 10/2 MC/ACcable

CS7

CS4

CS4

CS7

Features and Benefits• Positions cables at a safe distance from nailing surface

• CS4 provides a neat, organized cable installation and prevents tangles

• CS7 positions cable 2" from a furring strip or 2x4 stud• CS7 features positive lock to keep cables in place• Positions both flat and round NM cables• Complies with 2011 NEC Article 300-4d

R

R

R

R

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

STDPKG

DIMA

DIMB

DIMC

CS6 71006 500 1.750 2.000 .563CS60 71060 100 1.750 2.000 .563

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

STDPKG

DIMA

DIMB

DIMC

CS4 50174 100 4.100 .750 1.200CS7* 71007 100 3.490 .880 .740

Installation Instructions

Section_C_NM Cable 11/13/12 12:08 PM Page 10

Page 32: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

NM

Ca

ble

Arlington

www.aifittings.com Email: [email protected] Tel: (800) 233-4717 Fax: (570) 562-0646C-11

CS2 & CS20SCCable SupportsSupports up to four 14/2 - 10/2flat (any combination) and two14/3 - 10/3 (any combination)NM cables.

E161207 LR49636

CS2, CS20

NAIL

#8 self-tapping sheet metal screwCS20SC

To install the CS2:Position the CS2 in the desired location ona wood stud and drive in nail. Insert cableor cables.

To install the CS20SC:Position the CS20SC in the desired locationon a wood or metal stud and tighten self-tapping screw. Insert cable or cables.

CS2 on Wood Stud

C

B

A

CS20SC on Metal Stud

R

R

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

UNITPKG

STDPKG

DIMA

DIMB

DIMC

CS2 71002 500 500 2.650 2.530 .500CS20 71020 100 100 2.650 2.530 .500CS20SC 71025 100 100 2.704 2.563 .500CS20BAG 71022 25 100 2.650 2.530 .500

Installation Instructions

The Spacer™Cable SpacerNon-metallic cable spacerthat holds power or lowvoltage cables secure andcentered on a 2x4.

CS14

New! CATALOGNUMBER

UPC/DCI/NAEDMFG #018997 DESCRIPTION

UNITPKG

STDPKG

DIMA

DIMB

DIMC

CS14 33827 Nail on Cable Spacer 25 250 .633 3.296 1.920CS140 33829 Nail on Cable Spacer 500 500 .633 3.296 1.920CS140SC 01574 Screw on Cable Spacer 500 500 .633 3.296 1.920CS14SC 01573 Screw on Cable Spacer 25 250 .633 3.296 1.920

Section_C_NM Cable 11/13/12 12:08 PM Page 11

Page 33: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

New!

NM

Ca

ble

Arlington

C-12Fax: (570) 562-0646 Tel: (800) 233-4717 Email: [email protected] www.aifittings.com

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997 DESCRIPTION

UNITPKG

STDPKG

DIMA

DIMB

DIMC

WTC100 587321” Includes three letter-coded lands

50 50 1.583 1.450 1.610

WTC125 58733 1-1/4” Includes twoletter-coded glands 50 50 1.995 1.858 2.084

WTC150 58734 1-1/2” Includes twoletter-coded glands 10 10 2.025 2.100 2.400

WTC200 587352” Includes two

letter-coded glands10 10 2.150 2.560 2.917

WTC210 58736 2” Includes twoletter-coded glands 10 10 2.150 2.560 2.917

Gland-Type Service Entrance Cable ConnectorsZinc die-cast.

WTC100

WTC210 Features and Benefits• Each connector provides two to three glands that are listed to handle particular cable sizes.• Quick, easy installation of gland into connector• Saves time and money • Reduces inventory

Glands are Labeled A, B, or C, indicating what cable range they are good for.

CATALOGNUMBER

GlandsGrommetOpening MIN ID

GrommetOpening MAX ID

InsulatedConductor Size AWG

UninsulatedConductorSize AWG

WTC100

A .408 .655 #8 #8

B .445 .720 #6 #6

C .490 .795 #4 #4

WTC125A .600 .970 #2 #2

B .660 1.130 #1 #1

WTC150A .710 1.110 1/0 - 19 1/0

B .780 1.230 2/0 - 19 2/0

WTC200A .710 1.110 1/0 - 19 1/0

B .780 1.230 2/0 - 19 2/0

WTC210

A .830 1.400 3/0 - 19 3/0

B .906 1.435 4/0 - 19 4/0

C 1.110 1.580 4/0 - 19 4/0

Section_C_NM Cable 11/13/12 12:08 PM Page 12

Page 34: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

NM

Ca

ble

Arlington

www.aifittings.com Email: [email protected] Tel: (800) 233-4717 Fax: (570) 562-0646C-13

FITTINGS CABLE RANGE TYPE

BT50 1-14/2 to 1-8/3 NM2-12/3 NM4-14/2 NM

841, 841ST 1-14/2 & 1-14/3 1-14/2 to 10/2 NM1-14/2 & 1-12/3 1-14/3 to 10/3 NM1-12/2 & 1-14/3 2-14/2 to 10/2 NM1-12/2 & 1-12/3 1-14/2 & 1-12/2 NM2-14/2 & 1-14/3 1-14/2 & 1-10/2 NM2-14/2 & 1-12/3 1-12/2 & 1-10/2 NM

3-14/2 NM

NM74 1-14/2 to 1-10/2 2-14/2 to 2-10/2 NM1-14/3 to 1-10/3 2-14/3 NM

NM94 1-14/2 to 1-10/2 2-14/2 to 2-10/2 1-14/2 and 1-12/2 NM1-14/3 to 1-10/3 2-14/3 to 2-12/3 1-14/2 and 1-10/2 NM

1-12/2 and 1-10/2 NM1-14/3 and 1-12/3 NM

NM840 1-14/2 to 1-10/2 NM

NM841 1-14/2 to 6/2 2-14/2 to 10/2 NM1-14/3 to 10/3 2-14/2 & 1-14/3 NM1-14/2 & 1-12/2 2-14/2 & 1-12/3 NM1-14/2 & 1-10/2 2-14/2 & 1-12/2 NM1-12/2 & 1-10/2 2-14/2 & 1-10/2 NM1-14/2 & 1-14/3 2-14/3 NM1-14/2 & 1-12/3 3-14/2 NM1-12/2 & 1-14/3 1-14/2 & 2-12/2 NM1-12/2 & 1-12/3 1-14/2 & 2-10/2 NM1-8/2 & 1-14/2 1-6/2 NM1-8/2 & 1-12/2 NM

840, 840ST 1-14/2 to 10/2 NM8400, 8400ST 1-14/3 to 10/3 NM8401 2-14/2 to 10/2 NM

1-14/2 & 1-12/2 NM1-14/2 & 1-10/2 NM1-12/2 & 1-10/2 NM

BT75 1-8/2 to 1-6/2 NM842, 842ST 2-14/3 to 2-10/3 NMNM842* 1-8/3 to 1-6/3 NM

1-14/3 & 1-12/3 NM*Also listed for the combinations of NM842 on next page. 1-14/3 & 1-10/3 NM

1-12/3 & 1-10/3 NM1-8/2 to 1-4/2 SE

Continued next page

1/2" KO

3/4" KO

Section_C_NM Cable 11/13/12 12:08 PM Page 13

Page 35: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

NM

Ca

ble

Arlington

C-14Fax: (570) 562-0646 Tel: (800) 233-4717 Email: [email protected] www.aifittings.com

FITTINGS CABLE RANGE TYPE

8402 2-10/2 1-8/2 to 1-6/2 NM3-14/2 to 3-10/2 2-14/3 to 2-10/3 NM

1-8/3 to 1-6/3 NM1-14/3 & 1-12/3 NM1-14/3 & 1-10/3 NM1-12/3 & 1-10/3 NM1-8/2 to 1-4/2 SE

1-.530 to .570 x .840 to .930 1-.640 SE1-.375 to .685 2-.448 Flex Cord

1-.550 & 1-.375 Flex Cord

NM75 1-6/2 1-8/2 1-10/2 2-14/2 2-10/2 NM1-6/3 1-8/3 1-10/3 2-12/2 2-10/3 NM

NM95 1-14/2 to 1-6/2 2-14/2 to 2-10/2 1-14/2 and 1-12/2 NM1-14/3 to 1-6/3 2-14/3 to 2-10/3 1-14/2 and 1-10/2 NM

1-12/2 and 1-10/2 NM1-14/3 and 1-12/3 NM

NM842 3 to 4 14/2 to 10/2 plus any combination thereof. 2-10/2 & 1-14/3 to 2-10/2 & 1-12/3NM2-14/3 & 1-14/2 to 2-14/3 & 1-10/2 1-14/2 & 1-12/2 & 1-14/3 NM3-14/3 to 3-12/3 1-14/2 & 1-10/2 & 1-14/3 NM2-14/3 & 1-12/3 1-14/2 & 1-12/2 & 1-12/3 NM2-12/3 & 1-14/3 to 2-12/3 & 1-10/2 1-14/2 & 1-10/2 & 1-12/3 NM2-14/2 & 1-14/3 to 2-14/2 & 1-10/3 1-12/3 & 1-14/2 NM2-12/2 & 1-14/3 to 2-12/2 & 1-10/3 1-12/3 & 1-8/2 NM

843, 843S 2-10/3 to 2-8/3 1-6/2 to 1-4/2 1-10/3 & 1-8/2 NM, SE1-6/2 & 1-8/2 1-8/3 to 1-4/3 1-10/3 & 1-8/2 NM, SE2-6/2 to 1-8/3 2-10/3 to 2-8/2 2-8/2 NM, SE2-8/3 & 1-6/2 1-8/3 to 1-6/3 1-4/3 NM, SE3-8/2 to 3-6/2 1-12/3 & 1-8/2 1-12/3 & 1-10/3 NM, SE

NM843 2-10/3 and 2-8/2 1-8/3 to 1-4/3 3 to 6 14/3 NM1-8/3 and 2-6/2 NM2-8/3 and 1-6/2 NM

Any combination of above with minimum Outer Diameter of .580 and a maximum Outer Diameter of .960.

NM96 1-4/3 to 8/3 1-6/2 to 4/2 NM

NM844 1-4/3 to 1-6/3 NM2-6/3 to 2-10/3 NM4-10/2 NM10-12/2 NM9-14/2 Flex Cord1-.750 Flex Cord1-.580 x .950

1" KO

1-1/4" KO

Section_C_NM Cable 11/13/12 12:08 PM Page 14

Page 36: Arlington - MayerElectric.com€¦ · Arlington  Email: sales@aifittings.com Tel: (800) 233-4717 Fax: (570) 562-0646

Co

rd G

rip

s

Arlington

www.aifittings.com Email: [email protected] Tel: (800) 233-4717 Fax: (570) 562-0646D-1

AB

C

Low-ProfileStrain ReliefCord ConnectorsZinc die-cast. Liquid-tight • Oil-tight.Furnished with sealing ring and locknut.

Low-ProfileStrain ReliefCord ConnectorsNon-metallic. Liquid-tight • Oil-tight.Furnished withsealing ring and locknut.

Arlington’s Low Profile Cord Connector has a unique grommet with gripping fingers. These connectors have the largest cord range in theindustry, so there are fewer items to stock. A liquid-tight seal and superior pullout resistance is accomplished by just tightening the nut. A sealingring is furnished to assure a liquid-tight seal when installing in non-threaded openings.

A

C

E105706 LR49636

ZINCLOCKNUT

POLyETHyLENESEALING RING

ZINCBODy

NyLONGRIPPER

SANTOPRENE®

GROMMET

ZINCNUT

ZINCLOCKNUT

POLyETHyLENESEALING RING

NyLONBODy

NyLONGRIPPER

SANTOPRENE®

GROMMET

NyLONNUT

B

R

R

WHITE SEALINGRING MATCHES

PRODUCT

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

CORDRANGE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

LPCG503Z* 50352 1/2 .100-.300 25 100 1.792 .630 1.042LPCG50Z* 36110 1/2 .200-.472 25 100 1.792 .630 1.042LPCG507Z 50356 1/2 .385-.750 25 100 2.178 .517 1.305LPCG753Z* 36105 3/4 .100-.300 10 50 1.963 .570 1.042LPCG754Z 50764 3/4 .240-.472 10 50 1.963 .570 1.305LPCG757Z 50766 3/4 .385-750 10 50 2.250 .600 1.305

* UL not applicable for under .240 wire diameter -- wire strength will not meet UL’s 35lb pullout test requirement for the fitting.

CATALOGNUMBER

UPC/DCI/NAEDMFG #018997

TRADESIZE

CORDRANGE

UNITPKG

STDPKG

DIMA

DIMB

DIMC

LPCG503* 50350 1/2 .100-.300 25 100 1.792 .630 1.042LPCG50W 32875 1/2 .200-.472 25 100 1.792 .630 1.042LPCG50* 80086 1/2 .200-.472 25 100 1.792 .630 1.042LPCG507 50354 1/2 .385-.750 25 100 2.178 .517 1.305LPCG753* 50760 3/4 .100-.300 10 50 1.963 .570 1.042LPCG754 50762 3/4 .240-.472 10 50 1.963 .570 1.305LPCG757 36100 3/4 .385-.750 10 50 2.250 .600 1.30550LPCGBAG▲ 55080 1/2 .100-.472 - 500 1.792 .630 1.04275LPCGBAG▲ 55082 3/4 .100-.472 - 100 1.963 .570 1.305

E105706 LR49636

R

R

* UL not applicable for under .240 wire diameter -- wire strength will not meet UL’s 35lb test requirement for the fitting.

▲Includes UF grommet 14/2 to 12/2. Bags not available in black.When ordering in black, add suffix “BL” to catalog number.When ordering in white, add suffix “W” to catalog number.

Section_D_Cord Grips 11/5/12 1:51 PM Page 1


Related Documents