RFP #2017-16-M | 1

METROPOLITAN PIER AND EXPOSITION AUTHORITY

REQUEST FOR PROPOSALS #2017-16-M HVAC REPAIR AND MAINTENANCE SERVICES

ADDENDUM NO. (1)

August 1, 2017 This Addendum No. 1 consists of one (1) page and has the following information to be incorporated into the Request for Proposals. Proposers must acknowledge receipt of this Addendum No. 1 in their RFP submittal in Required Form A, Form of Transmittal Letter. Item #1: Proposers’ questions and/or requests and the MPEA’s responses are provided below.

Proposer Question:

MPEA’s Response:

Can MPEA provide the serial numbers on all the

compressors and dryers listed in Group 3 page 12? Model

numbers are listed but no serial numbers.

See attached revised scope.

Please carefully review the attached revised Scope of Services for each group.

Page 2: ADDENDUM NO. (1) - MPEA€¦ · Ingersoll-Rand LLE5A150 L0058 D 85-A Ingersoll-Rand LLE5A150 L0057 D 85-A Ingersoll-Rand SPA300 85818U 75 877 Elliott CP125M24 J-11027-1 Elliott CP125M24

REVISED - SCOPE OF SERVICES

Group 1: Ammonia Refrigeration

Contractor will perform on an as needed basis, repair, maintenance, upgrades and expansion of the MPEA’s industrial ammonia refrigeration systems. Contractors must demonstrate experience in the area of

ammonia refrigeration system maintenance and repairs as well as provide information on completed

projects.

Services include preventive maintenance and alterations to existing equipment. The Contractor will provide mechanical repair, millwright, alignment, tear down and overhaul of equipment as well as welding, general

electrical and control wiring.

Equipment Description

(3) 2,200 ton (nom.) ABB/Stal ammonia screw compressor trains Compressor Type. S93EB-26

(6) Evaporative Condensers i. BAC Model VC1-1608

All associated vessels, piping, valves, purger

Services Required

Provide preventive maintenance and non-emergency repair services for the above equipment which includes but is not limited to:

Replace compressor seals

Perform shaft alignment

Perform vibration analysis

Megger insulation test on compressor motor

Verify overload trip settings

Repair ammonia leaks

Perform oil analysis

Replace oil cooler thermostatic valve

Non-destructive testing of pipe and vessels

Slide valve repair

Periodic safety valve replacement

Contractor Qualifications and Responsibilities

a) Contractor must be able to provide service on all equipment listed within this Group.

b) Contractor must obtain all required permits.

c) Contractor must be OSHA and EPA refrigerant certified to work on any and all MPEA equipment.

d) Contractor must meet all federal and OSHA guidelines for handling and disposal of refrigerants.

e) Contractor must have a safety program that meets the requirements of both OSHA and EPA

regulations.

f) Contractor must have previous experience repairing and maintaining ammonia systems.

g) Contractor must employ certified welders qualified to work on or around ammonia systems.

h) Contractor must be able to provide knowledgeable and skilled employees available to respond

within 24 hours of contact from an MPEA supervisor.

i) Contractor must be able to make available qualified ammonia service technicians on an around

the clock basis.

Page 3: ADDENDUM NO. (1) - MPEA€¦ · Ingersoll-Rand LLE5A150 L0058 D 85-A Ingersoll-Rand LLE5A150 L0057 D 85-A Ingersoll-Rand SPA300 85818U 75 877 Elliott CP125M24 J-11027-1 Elliott CP125M24

REVISED - SCOPE OF SERVICES

j) Contractor must be able to provide a minimum of two account representatives knowledgeable

of the account, with one available at all times.

k) Contractor must demonstrate technical and procedural knowledge of ammonia systems.

l) Contractor must become familiar with the Process Safety Management (PSM) and Risk

Management (RM) guidelines as provided by the Authority.

m) Contractor must have at least 8 hours PSM Ammonia System training prior to working on all

Authority equipment.

n) Contractor must be able to write pre-startup safety review (PSSR) and management of change

(MOC) as required per the OSHA standard.

o) Contractor must maintain an injury and hazard related illness log related to its employees

working on or in the vicinity of the Authority’s ammonia system.

p) Each technician assigned to the job must be safety trained to meet OSHA, and general industry

standards.

q) Contractor must provide Material Safety Data Sheets (MSDS) for chemicals brought on site.

r) Contractor must provide daily legible service tickets for all work performed

s) Contractor must provide legible written reports for any test, analysis or inspection

t) Contractor must provide a statement outlining what type of training, if any, can be provided to

the owner’s employees either in general or regarding the specific equipment listed.

u) Contractor must complete an orientation prior to all projects. An annual refresher orientation

will be given for the Contractor on a regular basis. The Contractor and the Authority will

maintain a record of this training.

v) Contractor must provide evidence that the Contractor held site safety meetings for field

supervisors, employees and new hires.

w) Contractor must provide a copy of Contractor’s refrigeration license and/or certification.

x) Contractor must provide a copy of the Contractor’s training documentation for each employee

working on the Authority’s premises.

y) Contractor must provide evidence of Contractor’s Safety Program.

Page 4: ADDENDUM NO. (1) - MPEA€¦ · Ingersoll-Rand LLE5A150 L0058 D 85-A Ingersoll-Rand LLE5A150 L0057 D 85-A Ingersoll-Rand SPA300 85818U 75 877 Elliott CP125M24 J-11027-1 Elliott CP125M24

REVISED - SCOPE OF SERVICES

Experience

1. Contractor must provide a clear and concise statement of the Contractor’s area(s) of expertise, and the pertinence of that expertise.

2. Contractor must provide information highlighting the Contractor’s work on engagements similar in size and complexity.

3. Contractor must provide the information listed below for at least two projects for which Contractor

provided industrial ammonia refrigeration repair and maintenance services;

i. the name and location of the project

ii. the size and scale of the project iii. the scope of services provided on the project

4. Contractor must provide a description of experience of all staff expected to participate in the

Services.

5. Contractor must provide names and contact numbers of all sub-contractors that Contractor may employ to meet the requirements of the scope and the contract.

6. Contractor must provide an organizational chart showing the personnel hierarchy which will support the Authority’s account.

Page 5: ADDENDUM NO. (1) - MPEA€¦ · Ingersoll-Rand LLE5A150 L0058 D 85-A Ingersoll-Rand LLE5A150 L0057 D 85-A Ingersoll-Rand SPA300 85818U 75 877 Elliott CP125M24 J-11027-1 Elliott CP125M24

REVISED - SCOPE OF SERVICES

Group 2: Air Handling Units

Contractor will perform on an as needed basis, repair, maintenance, and upgrades of the MPEA’s air

handling units. Contractors must demonstrate experience in the area of air handling unit maintenance and repairs as well as provide information on completed projects.

Services include preventive maintenance and alterations to existing equipment. The Contractor will provide mechanical repair, millwright, alignment, tear down and overhaul of equipment as well as welding, general

electrical and control wiring.

Equipment Description

AIR HANDLING UNITS

Trane model MCCB********

Joy Industries model 48617702HV***

Hartzell model A15EH72****

Pace model PF*******

York model AP********

Peerless model AIRFOIL

Marlo model C2*

All associated coils, ductwork, dampers, piping, valves, and actuators

Services Required

Provide preventive maintenance and non-emergency repair services for the above equipment which

includes but is not limited to repair and/or replacement:

Coil

Condensate pan

Damper s

Fan blade

Bearing Shaft

Ductwork

Vane actuator

Fan housing

Contractor Qualifications and Responsibilities

a) Contractor must be able to provide service on all equipment listed within this category. Sub-

contractors are acceptable if required to meet this term of the agreement.

b) Contractor must obtain all required permits.

c) Contractor must be OSHA certified to work on any and all Authority equipment.

d) Contractor must have a safety program that meets the requirements OSHA regulations.

e) Contractor must be able to provide knowledgeable and skilled employees available to respond

within 24 hours of contact from an MPEA supervisor.

f) Contractor must be able to provide a minimum of two account representatives knowledgeable

of the account, with one available at all times

g) Each technician assigned to the job must be safety trained to meet OSHA, and general industry

standards.

h) Contractor must provide Material Safety Data Sheets (MSDS) for chemicals brought on site.

Page 6: ADDENDUM NO. (1) - MPEA€¦ · Ingersoll-Rand LLE5A150 L0058 D 85-A Ingersoll-Rand LLE5A150 L0057 D 85-A Ingersoll-Rand SPA300 85818U 75 877 Elliott CP125M24 J-11027-1 Elliott CP125M24

REVISED - SCOPE OF SERVICES

i) Contractor must provide daily legible service tickets for all work performed

j) Contractor must provide legible written reports for any test, analysis or inspection

k) Contractor must provide a statement outlining what type of training, if any, can be provided to

the owner’s employees either in general or regarding the specific equipment listed

l) Contractor must provide evidence of Contractor’s Safety Program.

Experience

1. Contractor must provide a clear and concise statement of the Contractor’s area(s) of expertise,

and the pertinence of that expertise.

2. Contractor must provide Information highlighting the Contractor’s work on engagements similar

in size and complexity.

3. Contractor must provide the information listed below for at least two projects for which Contractor

provided air handling unit repair or maintenance services;

i. the name and location of the project ii. the size and scale of the project

iii. the scope of services provided on the project

4. Contractor must provide a description of experience of all staff expected to participate in the

Services.

5. Contractor must provide names and contact numbers of all sub-contractors that Contractor may

employ to meet the terms of this agreement

6. Contractor must provide an organizational chart showing the personnel hierarchy which will

support the Authority’s account.

Page 7: ADDENDUM NO. (1) - MPEA€¦ · Ingersoll-Rand LLE5A150 L0058 D 85-A Ingersoll-Rand LLE5A150 L0057 D 85-A Ingersoll-Rand SPA300 85818U 75 877 Elliott CP125M24 J-11027-1 Elliott CP125M24

REVISED - SCOPE OF SERVICES

Group 3: Air Compressors

Contractor will perform on an as needed basis, repair, maintenance, and upgrades of the MPEA’s

compressed air systems. Contractors must demonstrate experience in maintenance and repairs of compressed air equipment as well as provide information on completed projects.

Services include preventive maintenance and alterations to existing equipment. The Contractor will provide mechanical repair, millwright, alignment, tear down and overhaul of equipment as well as welding, general

electrical and control wiring.

Equipment Description

Air Compressors

Equipment Brand Model Number Serial Number

Atlas Copco GA200W AIF106077

Atlas Copco GA200W AIF106022

Atlas Copco GA200W AIF106078

Atlas Copco GA75 Plus API601363

Atlas Copco GA200W AIF 021 851

Atlas Copco GA200W AIF 021 263

Atlas Copco GA200W AIF 018 875

Atlas Copco GA75 HOL020939

Atlas Copco GA315 AIF064751

Quincy 5120-120 408149

Quincy 5120-120 399830

Quincy 5120-105 6147179

Quincy 5120-105 6147175

Quincy 5120 A 104 6172956

Quincy 5120 A 103 6067306

Ingersoll-Rand LLE5A150 L0059 D 85-A

Ingersoll-Rand LLE5A150 L0060 D 85-A

Ingersoll-Rand LLE5A150 L0058 D 85-A

Ingersoll-Rand LLE5A150 L0057 D 85-A

Ingersoll-Rand SPA300 85818U 75 877

Elliott CP125M24 J-11027-1

Elliott CP125M24 J-11027-2

Sullair E-8 series 201012090069

Air Dryers and Dryer Control Panels

Pneumatech AD-100 9507-T121067-ST

Air Tak BPD-5000 00-05-010

Air Tak EHD-3800 06-03-042

Ingersoll-Rand D110IM 15DME122230

Ingersoll-Rand F401W 364233

Page 8: ADDENDUM NO. (1) - MPEA€¦ · Ingersoll-Rand LLE5A150 L0058 D 85-A Ingersoll-Rand LLE5A150 L0057 D 85-A Ingersoll-Rand SPA300 85818U 75 877 Elliott CP125M24 J-11027-1 Elliott CP125M24

REVISED - SCOPE OF SERVICES

Services Required

Provide preventive maintenance and non-emergency repair services for the above equipment

which includes but is not limited to: Operating inspection

Replace seals.

Megger insulation test on compressor motor.

Perform oil analysis.

Contractor Qualifications and Responsibilities

a) Contractor must be able to provide service on all equipment listed within this category. Sub-

contractors are acceptable if required to meet this term of the agreement.

b) Contractor must obtain all required permits.

c) Contractor must be OSHA certified to work on any and all Authority equipment.

d) Contractor must have a safety program that meets the requirements of OSHA regulations.

e) Contractor must be able to provide knowledgeable and skilled employees available to respond

within 24 hours of contact from an MPEA supervisor.

f) Contractor must be able to provide a minimum of two account representatives knowledgeable

of the account, with one available at all times

g) Each technician assigned to the job must be safety trained to meet OSHA, and general industry

standards.

h) Contractor must provide Material Safety Data Sheets (MSDS) for chemicals brought on site.

i) Contractor must provide daily legible service tickets for all work performed

j) Contractor must provide legible written reports for any test, analysis or inspection

k) Contractor must provide a statement outlining what type of training, if any, can be provided to

the owner’s employees either in general or regarding the specific equipment listed

l) Contractor must provide evidence of Contractor’s Safety Program.

Page 9: ADDENDUM NO. (1) - MPEA€¦ · Ingersoll-Rand LLE5A150 L0058 D 85-A Ingersoll-Rand LLE5A150 L0057 D 85-A Ingersoll-Rand SPA300 85818U 75 877 Elliott CP125M24 J-11027-1 Elliott CP125M24

REVISED - SCOPE OF SERVICES

Experience

1. Contractor must provide a clear and concise statement of the Contractor’s area(s) of expertise, and the pertinence of that expertise.

2. Contractor must provide Information highlighting the Contractor’s work on engagements similar

in size and complexity.

3. Contractor must provide the information listed below for at least two projects for which Contractor

provided air compressor repair or maintenance services;

i. the name and location of the project

ii. the size and scale of the project

iii. the scope of services provided on the project

4. Contractor must provide a description of experience of all staff expected to participate in the Services.

5. Contractor must provide names and contact numbers of all sub-contractors that Contractor may employ to meet the terms of this agreement

6. Contractor must provide an organizational chart showing the personnel hierarchy which will

support the Authority’s account.

Page 10: ADDENDUM NO. (1) - MPEA€¦ · Ingersoll-Rand LLE5A150 L0058 D 85-A Ingersoll-Rand LLE5A150 L0057 D 85-A Ingersoll-Rand SPA300 85818U 75 877 Elliott CP125M24 J-11027-1 Elliott CP125M24

REVISED - SCOPE OF SERVICES

Group 4: Carrier Chillers

Contractor will perform on an as needed basis, repair, maintenance, and upgrades of the MPEA’s Carrier

chiller systems. Contractors must demonstrate experience in maintenance and repairs of Carrier Chillers as well as provide information on completed projects.

Services include preventive maintenance and alterations to existing equipment. The Contractor will provide mechanical repair, millwright, alignment, tear down and overhaul of equipment as well as welding, general

electrical and control wiring.

Equipment Description

(3) Carrier

Compressor Type 19FA553B5002424LEB (2) Carrier

Compressor Type 17DA72-128-1

All associated vessels, piping, valves, pump out unit and refrigeration monitoring system

Services Required

Provide preventive maintenance and non-emergency repair services for the above equipment which includes but is not limited to:

Repair refrigerant leaks

Check compressor bearings measurement and tolerance.

Inspect compressor shafts.

Inspect compressor and seals

Inspect compressor limit switches

Perform shaft alignment.

Perform vibration analysis

Megger insulation test on compressor motor

Check amperage imbalance

Verify overload trip settings

Complete leak check

Inspect starter panel for pitting

Torque all compressor electrical connections

Perform oil and refrigerant analysis

Inspect oil heater and pump

Contractor Qualifications and Responsibilities

a) Contractor must provide a copy of Contractor’s refrigeration license and/or certification.

b) Contractor must be able to provide service on all equipment listed within this category. Sub-

contractors are acceptable if required to meet this term of the agreement.

c) Contractor must obtain all required permits.

d) Contractor must be OSHA and EPA refrigerant certified to work on any and all Authority

equipment.

e) Contractor must meet all federal and OSHA guidelines for handling and disposal of refrigerants.

Page 11: ADDENDUM NO. (1) - MPEA€¦ · Ingersoll-Rand LLE5A150 L0058 D 85-A Ingersoll-Rand LLE5A150 L0057 D 85-A Ingersoll-Rand SPA300 85818U 75 877 Elliott CP125M24 J-11027-1 Elliott CP125M24

REVISED - SCOPE OF SERVICES

f) Contractor must have a safety program that meets the requirements of both OSHA and EPA

regulations.

g) Contractor must have previous experience repairing and maintaining Carrier Chillers.

h) Contractor must be able to provide knowledgeable and skilled employees available to respond

within 24 hours of contact from an MPEA supervisor.

i) Contractor must be able to provide a minimum of two account representatives knowledgeable

of the account, with one available at all times

j) Each technician assigned to the job must be safety trained to meet OSHA, and general industry

standards.

k) Contractor must provide Material Safety Data Sheets (MSDS) for chemicals brought on site.

l) Contractor must provide daily legible service tickets for all work performed

m) Contractor must provide legible written reports for any test, analysis or inspection

n) Contractor must provide a statement outlining what type of training, if any, can be provided to

the owner’s employees either in general or regarding the specific equipment listed

o) Contractor must provide evidence of Contractor’s Safety Program.

Experience

1. Contractor must provide a clear and concise statement of the Contractor’s area(s) of expertise, and the pertinence of that expertise.

2. Contractor must provide Information highlighting the Contractor’s work on engagements similar

in size and complexity.

3. Contractor must provide the information listed below for at least two projects for which Contractor

provided repair or maintenance services of Carrier Chillers;

i. the name and location of the project

ii. the size and scale of the project iii. the scope of services provided on the project

4. Contractor must provide a description of experience of all staff expected to participate in the Services.

5. Contractor must provide names and contact numbers of all sub-contractors that Contractor may employ to meet the terms of this agreement

6. Contractor must provide an organizational chart showing the personnel hierarchy which will

support the Authority’s account.

Page 12: ADDENDUM NO. (1) - MPEA€¦ · Ingersoll-Rand LLE5A150 L0058 D 85-A Ingersoll-Rand LLE5A150 L0057 D 85-A Ingersoll-Rand SPA300 85818U 75 877 Elliott CP125M24 J-11027-1 Elliott CP125M24

REVISED - SCOPE OF SERVICES

Group 5: Trane Chillers

Contractor will perform on an as needed basis, repair, maintenance, and upgrades of the MPEA’s Trane

chiller systems. Contractors must demonstrate experience in maintenance and repairs of Trane Chillers as well as provide information on completed projects.

Services include preventive maintenance and alterations to existing equipment. The Contractor will provide mechanical repair, millwright, alignment, tear down and overhaul of equipment as well as welding, general

electrical and control wiring.

Equipment Description

(8) Trane Centrifugal chillers Compressor Type. CVHF1470

All associated vessels, piping, valves, pump out units and refrigeration monitoring system

Services Required

Provide preventive maintenance and non-emergency repair services for the above equipment which includes but is not limited to:

Operation inspection

Eddy Current testing

Perform vibration analysis.

Megger insulation test on compressor motor.

Verify overload trip settings.

Repair refrigerant leaks.

Perform oil analysis.

Contractor Qualifications and Responsibilities

a) Contractor must be able to provide service on all equipment listed within this category. Sub-

contractors are acceptable if required to meet this term of the agreement.

b) Contractor must provide a copy of Contractor’s refrigeration license and/or certification.

c) Contractor must obtain all required permits.

d) Contractor must be OSHA and EPA refrigerant certified to work on any and all Authority

equipment.

e) Contractor must meet all federal and OSHA guidelines for handling and disposal of refrigerants.

f) Contractor must have a safety program that meets the requirements of both OSHA and EPA

regulations.

g) Contractor must provide evidence of Contractor’s Safety Program.

h) Contractor must have previous experience repairing and maintaining Trane Chillers.

i) Contractor must be able to provide knowledgeable and skilled employees available to respond

within 24 hours of contact from an MPEA supervisor.

j) Contractor must be able to provide a minimum of two account representatives knowledgeable

of the account, with one available at all times

k) Each technician assigned to the job must be safety trained to meet OSHA, and general industry

standards.

l) Contractor must provide Material Safety Data Sheets (MSDS) for chemicals brought on site.

m) Contractor must provide daily legible service tickets for all work performed

Page 13: ADDENDUM NO. (1) - MPEA€¦ · Ingersoll-Rand LLE5A150 L0058 D 85-A Ingersoll-Rand LLE5A150 L0057 D 85-A Ingersoll-Rand SPA300 85818U 75 877 Elliott CP125M24 J-11027-1 Elliott CP125M24

REVISED - SCOPE OF SERVICES

n) Contractor must provide legible written reports for any test, analysis or inspection

o) Contractor must provide a statement outlining what type of training, if any, can be provided to

the owner’s employees either in general or regarding the specific equipment listed

Experience

1. Contractor must provide a clear and concise statement of the Contractor’s area(s) of expertise,

and the pertinence of that expertise.

2. Contractor must provide Information highlighting the Contractor’s work on engagements similar in size and complexity.

3. Contractor must provide the information listed below for at least two projects for which Contractor provided repair or maintenance services of Trane Chillers;

i. the name and location of the project ii. the size and scale of the project

iii. the scope of services provided on the project

4. Contractor must provide a description of experience of all staff expected to participate in the

Services.

5. Contractor must provide names and contact numbers of all sub-contractors that Contractor may

employ to meet the terms of this agreement

6. Contractor must provide an organizational chart showing the personnel hierarchy which will support the Authority’s account.

Page 14: ADDENDUM NO. (1) - MPEA€¦ · Ingersoll-Rand LLE5A150 L0058 D 85-A Ingersoll-Rand LLE5A150 L0057 D 85-A Ingersoll-Rand SPA300 85818U 75 877 Elliott CP125M24 J-11027-1 Elliott CP125M24

REVISED - SCOPE OF SERVICES

Group 6: Evapco Cooling Towers

Contractor will perform on an as needed basis, repair, maintenance and upgrades of the MPEA’s Evapco

cooling towers systems. Contractors must demonstrate experience in maintenance and repairs of Evapco cooling towers as well as provide information on completed projects.

Services include preventive maintenance and alterations to existing equipment. The Contractor will provide mechanical repair, millwright, alignment, tear down and overhaul of equipment as well as welding, general

electrical and control wiring.

Equipment Description

12 Evapco Cooling towers, model AT228-0424 All associated piping and valves

Services Required

Provide preventive maintenance and non-emergency repair services for the above equipment

which includes but is not limited to: Fan blade replacement

Bearing and shaft repair

Sump sealing

Nozzle replacement.

Motor replacement

Spring replacement

Contractor Qualifications and Responsibilities

a) Contractor must be able to provide service on all equipment listed within this category. Sub-

contractors are acceptable if required to meet this term of the agreement.

b) Contractor must obtain all required permits.

c) Contractor must be OSHA certified to work on any and all Authority equipment.

d) Contractor must have a safety program that meets the requirements of OSHA regulations.

e) Contractor must have previous experience repairing and maintaining Evapco cooling towers.

f) Contractor must be able to provide knowledgeable and skilled employees available to respond

within 24 hours of contact from an MPEA supervisor.

g) Contractor must be able to provide a minimum of two account representatives knowledgeable

of the account, with one available at all times

h) Each technician assigned to the job must be safety trained to meet OSHA, and general industry

standards.

i) Contractor must provide Material Safety Data Sheets (MSDS) for chemicals brought on site.

j) Contractor must provide daily legible service tickets for all work performed

k) Contractor must provide legible written reports for any test, analysis or inspection

l) Contractor must provide a statement outlining what type of training, if any, can be provided to

the owner’s employees either in general or regarding the specific equipment listed

m) Contractor must provide evidence of Contractor’s Safety Program.

Page 15: ADDENDUM NO. (1) - MPEA€¦ · Ingersoll-Rand LLE5A150 L0058 D 85-A Ingersoll-Rand LLE5A150 L0057 D 85-A Ingersoll-Rand SPA300 85818U 75 877 Elliott CP125M24 J-11027-1 Elliott CP125M24

REVISED - SCOPE OF SERVICES

Experience

1. Contractor must provide a clear and concise statement of the Contractor’s area(s) of expertise, and the pertinence of that expertise.

2. Contractor must provide information highlighting the Contractor’s work on engagements similar in size and complexity.

3. Contractor must provide the information listed below for at least two projects for which

Contractor provided Evapco cooling tower repair and/or maintenance services;

i. the name and location of the project

ii. the size and scale of the project iii. the scope of services provided on the project

4. Contractor must provide a description of experience of all staff expected to participate in the

Services.

5. Contractor must provide names and contact numbers of all sub-contractors that Contractor may employ to meet the terms of this agreement

6. Contractor must provide an organizational chart showing the personnel hierarchy which will support the Authority’s account.

Page 16: ADDENDUM NO. (1) - MPEA€¦ · Ingersoll-Rand LLE5A150 L0058 D 85-A Ingersoll-Rand LLE5A150 L0057 D 85-A Ingersoll-Rand SPA300 85818U 75 877 Elliott CP125M24 J-11027-1 Elliott CP125M24

REVISED - SCOPE OF SERVICES

Group 7: Indeck Water Tube Boilers

Contractor will perform on an as needed basis, repair, maintenance, and upgrades to MPEA’s Indeck water

tube boiler systems. Contractor must demonstrate experience in the area of repair and maintenance of Indeck water tube boilers as well as provide information on completed projects. Services include the preventive maintenance of, and alterations to existing equipment. The Contractor will

provide mechanical repair, refractory repair, millwright, tear down and overhaul of equipment as well as

welding, general electrical and control wiring.

Equipment Description

(2) Indeck Boiler model D4-80R

(1) Indeck

Boiler model HOR-80

(1) Industrial Steam

Deaerator model 90SF5-CS(M)

Services Required

Provide preventive maintenance and non-emergency repair services for the above equipment

which includes but is not limited to:

burner tune-up

operating inspection

tube repair

refractory inspection and repair

safety valve inspection and repair

Contractor Qualifications and Responsibilities

a) Contractor must be able to provide service on all equipment listed within this category. Sub-

contractors are acceptable if required to meet this term of the agreement.

b) Contractor must obtain all required permits.

c) Contractor must be OSHA certified to work on any and all Authority equipment.

d) Contractor must have a safety program that meets the requirements of OSHA regulations.

e) Contractor must employ certified welders qualified to work on pressure vessels.

f) Contractor must be able to provide knowledgeable and skilled employees available to respond

within 24 hours of contact from an MPEA supervisor.

g) Contractor must be able to provide a minimum of two account representatives knowledgeable

of the account, with one available at all times.

h) Each technician assigned to the job must be safety trained to meet OSHA, and general industry

standards.

i) Contractor must provide Material Safety Data Sheets (MSDS) for chemicals brought on site.

j) Contractor must provide daily legible service tickets for all work performed.

k) Contractor must provide legible written reports for any test, analysis or inspection.

l) Contractor must provide a statement outlining what type of training, if any, can be provided to

the owner’s employees either in general or regarding the specific equipment listed.

Page 17: ADDENDUM NO. (1) - MPEA€¦ · Ingersoll-Rand LLE5A150 L0058 D 85-A Ingersoll-Rand LLE5A150 L0057 D 85-A Ingersoll-Rand SPA300 85818U 75 877 Elliott CP125M24 J-11027-1 Elliott CP125M24

REVISED - SCOPE OF SERVICES

m) Contractor must provide evidence of Contractor’s Safety program.

Experience

1. Contractor must provide a clear and concise statement of the Contractor’s area(s) of expertise,

and the pertinence of that expertise.

2. Contractor must provide information highlighting the Contractor’s work on engagements similar in size and complexity.

3. Contractor must provide the information listed below for at least two projects for which Contractor provided Indeck water tube boiler repair or maintenance services;

i. the name and location of the project ii. the size and scale of the project

iii. the scope of services provided on the project

4. Contractor must provide a description of experience of all staff expected to participate in the

Services.

5. Contractor must provide names and contact numbers of all sub-contractors that Contractor may

employ to meet the terms of this agreement

6. Contractor must provide an organizational chart showing the personnel hierarchy which will support the Authority’s account.

Page 18: ADDENDUM NO. (1) - MPEA€¦ · Ingersoll-Rand LLE5A150 L0058 D 85-A Ingersoll-Rand LLE5A150 L0057 D 85-A Ingersoll-Rand SPA300 85818U 75 877 Elliott CP125M24 J-11027-1 Elliott CP125M24

REVISED - SCOPE OF SERVICES

Group 8: Cleaver Brooks Fire Tube Boilers

Contractor will perform on an as needed basis, repair, maintenance, and upgrades to MPEA’s Cleaver Brooks

fire tube boiler system. Contractor must demonstrate experience in the area of repair and maintenance of Cleaver Brooks fire tube boilers as well as provide information on completed projects. Services include the preventive maintenance of, and alterations to existing equipment. The Contractor will

provide mechanical repair, refractory repair, millwright, tear down and overhaul of equipment as well as

welding, general electrical and control wiring.

Equipment Description

(3) Cleaver Brooks boilers Boiler model CBL-700-1200-250

(1) Cleaver Brooks deaerator dearator model SMP200-100693K

(1) Cleaver Brooks surge tank

Surge tank model SRG88093F

Services Required

Provide preventive maintenance and non-emergency repair services for the above equipment

which includes but is not limited to: burner tune-up

operating inspection

tube repair

tube replacement

safety valve inspection and repair

Contractor Qualifications and Responsibilities

a) Contractor must be able to provide service on all equipment listed within this category. Sub-

contractors are acceptable if required to meet this term of the agreement.

b) Contractor must obtain all required permits.

c) Contractor must be OSHA certified to work on any and all Authority equipment.

d) Contractor must have a safety program that meets the requirements of OSHA regulations.

e) Contractor must employ certified welders qualified to work on pressure vessels.

f) Contractor must be able to provide knowledgeable and skilled employees available to respond

within 24 hours of contact from an MPEA supervisor.

g) Contractor must be able to provide a minimum of two account representatives knowledgeable

of the account, with one available at all times

h) Each technician assigned to the job must be safety trained to meet OSHA, and general industry

standards.

i) Contractor must provide Material Safety Data Sheets (MSDS) for chemicals brought on site.

j) Contractor must provide daily legible service tickets for all work performed

k) Contractor must provide legible written reports for any test, analysis or inspection

l) Contractor must provide a statement outlining what type of training, if any, can be provided to

the owner’s employees either in general or regarding the specific equipment listed

Page 19: ADDENDUM NO. (1) - MPEA€¦ · Ingersoll-Rand LLE5A150 L0058 D 85-A Ingersoll-Rand LLE5A150 L0057 D 85-A Ingersoll-Rand SPA300 85818U 75 877 Elliott CP125M24 J-11027-1 Elliott CP125M24

REVISED - SCOPE OF SERVICES

m) Contractor must provide evidence of Contractor’s Safety Program.

Experience

1. Contractor must provide a clear and concise statement of the Contractor’s area(s) of expertise,

and the pertinence of that expertise.

2. Contractor must provide information highlighting the Contractor’s work on engagements similar in size and complexity.

3. Contractor must provide the information listed below for at least two projects for which Contractor provided Cleaver Brooks fire tube boiler repair or maintenance services;

i. the name and location of the project ii. the size and scale of the project

iii. the scope of services provided on the project

4. Contractor must provide a description of experience of all staff expected to participate in the

Services.

5. Contractor must provide names and contact numbers of all sub-contractors that Contractor may

employ to meet the terms of this agreement

6. Contractor must provide an organizational chart showing the personnel hierarchy which will support the Authority’s account.

Page 20: ADDENDUM NO. (1) - MPEA€¦ · Ingersoll-Rand LLE5A150 L0058 D 85-A Ingersoll-Rand LLE5A150 L0057 D 85-A Ingersoll-Rand SPA300 85818U 75 877 Elliott CP125M24 J-11027-1 Elliott CP125M24

REVISED - SCOPE OF SERVICES

Group 9: Flow and Energy Meters

Contractor will perform on an as needed basis, repair, maintenance, and upgrades to MPEA’s Flow and

Energy meters. Contractor must demonstrate experience in the area of repair and maintenance of flow and energy meters as well as provide information on completed projects.

Services include the preventive maintenance of, repair, and alterations to existing equipment. The Contractor will provide mechanical repair, set up, calibration and testing of equipment.

Equipment Description

Meters

Siemens model 1010********

Yokogawa model YF*****

Yokogawa model DY*****

Flexim model Fluxus F-704

Onicon model F-3100

Services Required

Provide preventive maintenance and non-emergency repair services for the above equipment which

includes but is not limited to: Annual calibration

And repair and/or replacement of:

Transducers

RTDs

Flow sensors

Control boards

Complete units Contractor Qualifications and Responsibilities

a) Contractor must be able to provide service on all equipment listed within this category. Sub-

contractors are acceptable if required to meet this term of the agreement.

b) Contractor must obtain all required permits.

c) Contractor must be OSHA certified to work on any and all Authority equipment.

d) Contractor must have a safety program that meets the requirements of OSHA regulations.

e) Contractor must be able to provide knowledgeable and skilled employees available to respond

within 24 hours of contact from an MPEA supervisor.

f) Contractor must be able to provide a minimum of two account representatives knowledgeable

of the account, with one available at all times

g) Each technician assigned to the job must be safety trained to meet OSHA, and general industry

standards.

h) Contractor must provide Material Safety Data Sheets (MSDS) for chemicals brought on site.

i) Contractor must provide daily legible service tickets for all work performed

j) Contractor must provide legible written reports for any test, analysis or inspection

Page 21: ADDENDUM NO. (1) - MPEA€¦ · Ingersoll-Rand LLE5A150 L0058 D 85-A Ingersoll-Rand LLE5A150 L0057 D 85-A Ingersoll-Rand SPA300 85818U 75 877 Elliott CP125M24 J-11027-1 Elliott CP125M24

REVISED - SCOPE OF SERVICES

k) Contractor must provide a statement outlining what type of training, if any, can be provided to

the owner’s employees either in general or regarding the specific equipment listed

l) Contractor must provide evidence of Contractor’s Safety Program.

Experience

1. Contractor must provide a clear and concise statement of the Contractor’s area(s) of expertise,

and the pertinence of that expertise.

2. Contractor must provide information highlighting the Contractor’s work on engagements similar

in size and complexity.

3. Contractor must provide the information listed below for at least two projects for which

Contractor provided flow and energy meter repair or maintenance services;

i. the name and location of the project ii. the size and scale of the project

iii. the scope of services provided on the project

4. Contractor must provide a description of experience of all staff expected to participate in the

Services.

5. Contractor must provide names and contact numbers of all sub-contractors that Contractor may

employ to meet the terms of this agreement

6. Contractor must provide an organizational chart showing the personnel hierarchy which will

support the Authority’s account.

Page 22: ADDENDUM NO. (1) - MPEA€¦ · Ingersoll-Rand LLE5A150 L0058 D 85-A Ingersoll-Rand LLE5A150 L0057 D 85-A Ingersoll-Rand SPA300 85818U 75 877 Elliott CP125M24 J-11027-1 Elliott CP125M24

REVISED - SCOPE OF SERVICES

Group 10: Insulation Repair and Replacement

Contractor will perform on an as needed basis, repair, maintenance, and upgrades of mechanical insulation

on equipment, vessels, ductwork and piping at MPEA facilities. Contractor must demonstrate experience in the area of repair, replacement, and maintenance of mechanical insulation as well as provide information

on completed projects. Services include the preventive maintenance, repair, replacement and alterations to existing equipment.

Services Required

The Contractor will repair and replace all types of mechanical insulation on boilers, chillers, vessels, pumps, heat exchangers, piping and related equipment.

Contractor Qualifications and Responsibilities

a) Contractor must be OSHA certified to work on any and all Authority equipment.

b) Contractor must have a safety program that meets the requirements of OSHA regulations.

c) Contractor must provide evidence of Contractor’s Safety Program.

d) Contractor must be able to provide knowledgeable and skilled employees available to respond

within 24 hours of contact from an MPEA supervisor.

e) Each technician assigned to the job must be safety trained to meet OSHA, and general industry

standards.

f) Contractor must provide Material Safety Data Sheets (MSDS) for chemicals brought on site.

g) Contractor must provide daily legible service tickets for all work performed

h) Contractor must provide legible written reports for any test, analysis or inspection

i) Contractor must provide a statement outlining what type of training, if any, can be provided to

the owner’s employees either in general or regarding the specific equipment listed

Experience

1. Contractor must provide a clear and concise statement of the Contractor’s area(s) of expertise, and the pertinence of that expertise.

2. Contractor must provide information highlighting the Contractor’s work on engagements similar in size and complexity.

3. Contractor must provide the information listed below for at least two projects for which

Contractor provided insulation repair and replacement services:

i. the name and location of the project

ii. the size and scale of the project iii. the scope of services provided on the project

4. Contractor must provide a description of experience of all staff expected to participate in the

Services.

5. Contractor must provide names and contact numbers of all sub-contractors that Contractor may employ to meet the terms of this agreement

6. Contractor must provide an organizational chart showing the personnel hierarchy which will support the Authority’s account.

Page 23: ADDENDUM NO. (1) - MPEA€¦ · Ingersoll-Rand LLE5A150 L0058 D 85-A Ingersoll-Rand LLE5A150 L0057 D 85-A Ingersoll-Rand SPA300 85818U 75 877 Elliott CP125M24 J-11027-1 Elliott CP125M24

REVISED - SCOPE OF SERVICES

Group 11: Pumps

Contractor will perform on an as needed basis, repair, maintenance, and upgrades to MPEA’s pumping

systems. Contractor must demonstrate experience in the area of repair and maintenance of various pumps as well as provide information on completed projects. Services include the preventive maintenance of, and alterations to existing equipment. The Contractor will

provide mechanical repair, refractory repair, millwright, tear down and overhaul of equipment as well as

welding, general electrical and control wiring.

Equipment Description

Pumps

(5) Armstrong model 12X12X17 43TCZ (8) Armstrong model 10X10X13 4300T

(12) Armstrong model 8X8X15 4300TC (2) Armstrong model 3X3X8 4380

(3) Grundfos model CR45-4-1 KGAE-KUBE (3) Grundfos model CR45-1K-G-A-E-KUBE

(1) Grundfos model C40000063P19944

(2) Bell and Gossett model 1510 5E 10.625 (2) Bell and Gossett model 1511 6G 11.25BF

(2) Bell and Gossett model 6G11.250SBF (2) Bell and Gossett model 6BC8.375BF

(2) Bell and Gossett model 5E10.6.25BF

(2) Bell and Gossett model 40-5 1BB116 (1) Bell and Gossett model 80BF9

(1) Bell and Gossett model Domestic A71 (1) Bell and Gossett model VSCS 12-1/4 BF RHR

(4) Taco model TA1548B3Y1C2LO (3) Worthington model 16FRB-224

(3) Worthington model 8 FRBH183

(3) Worthington model 18FRBH 274 (6) Worthington model 12FR 192

(8) Aurora model 411BF (2) Aurora model 411SCBF

(3) Aurora model H05 135 BF

(1) Aurora model 5-481-11C (2) Flow serve model 2X 1 .125

(1) Ebara model EVMU188-8 (2) Ebara model EVMUG455-0

(4) Ingersoll-Dresser model 2.5 X 1.5X6 (3) Peerless model 10A16B

(1) Peerless model 6A16

(3) Peerless model 12A16 (3) Peerless model 8A13B

(3) Peerless model 10A14B (2) Nash model H5

Page 24: ADDENDUM NO. (1) - MPEA€¦ · Ingersoll-Rand LLE5A150 L0058 D 85-A Ingersoll-Rand LLE5A150 L0057 D 85-A Ingersoll-Rand SPA300 85818U 75 877 Elliott CP125M24 J-11027-1 Elliott CP125M24

REVISED - SCOPE OF SERVICES

Services Required

Provide preventive maintenance and non-emergency repair services for the above equipment which

includes but is not limited to: Operating inspection

Bearing replacement

Seal repair

Seal replacement

Shaft resurfacing

Dynamic balancing

Contractor Qualifications and Responsibilities

a) Contractor must be able to provide service on all equipment listed within this category. Sub-

contractors are acceptable if required to meet this term of the agreement.

b) Contractor must obtain all required permits.

c) Contractor must be OSHA certified to work on any and all Authority equipment.

d) Contractor must have a safety program that meets the requirements of OSHA regulations.

e) Contractor must provide evidence of Contractor’s Safety Program.

f) Contractor must be able to provide knowledgeable and skilled employees available to respond

within 24 hours of contact from an MPEA supervisor.

g) Contractor must be able to provide a minimum of two account representatives knowledgeable

of the account, with one available at all times

h) Each technician assigned to the job must be safety trained to meet OSHA, and general industry

standards.

i) Contractor must provide Material Safety Data Sheets (MSDS) for chemicals brought on site.

j) Contractor must provide daily legible service tickets for all work performed

k) Contractor must provide legible written reports for any test, analysis or inspection

l) Contractor must provide a statement outlining what type of training, if any, can be provided to

the owner’s employees either in general or regarding the specific equipment listed

m) Contractor must be available throughout the term to perform services for the Authority

whenever and/or if the Authority issues the Contractor one or more purchase orders.

Page 25: ADDENDUM NO. (1) - MPEA€¦ · Ingersoll-Rand LLE5A150 L0058 D 85-A Ingersoll-Rand LLE5A150 L0057 D 85-A Ingersoll-Rand SPA300 85818U 75 877 Elliott CP125M24 J-11027-1 Elliott CP125M24

REVISED - SCOPE OF SERVICES

Experience

1. Contractor must provide a clear and concise statement of the Contractor’s area(s) of expertise,

and the pertinence of that expertise.

7. Contractor must provide Information highlighting the Contractor’s work on engagements similar

in size and complexity.

2. Contractor must provide the information listed below for at least two projects for which

Contractor provided pump repair or maintenance services;

i. the name and location of the project ii. the size and scale of the project

iii. the scope of services provided on the project 3. Contractor must provide a description of experience of all staff expected to participate in the

Services.

4. Contractor must provide names and contact numbers of all sub-contractors that Contractor may

employ to meet the terms of this agreement

5. Contractor must provide an organizational chart showing the personnel hierarchy which will support the Authority’s account.


Related Documents