Page 1: A novel technique has been proposed for dynamic MRI: Dynamic KWIC Permits image reconstruction at both high spatial and high temporal resolutions Technique.

• A novel technique has been proposed for dynamic MRI: Dynamic KWIC

• Permits image reconstruction at both high spatial and high temporal resolutions

• Technique is based on an angle-interleaved projection reconstruction (PR) data acquisition and temporally selective data filtering

• Effective temporal resolution is equal to a highly undersampled PR technique, but image quality similar to a fully sampled data set

Dynamic KWIC for Simultaneous High Spatial and High Temporal Resolution Imaging

Page 2: A novel technique has been proposed for dynamic MRI: Dynamic KWIC Permits image reconstruction at both high spatial and high temporal resolutions Technique.

Need for High Spatial and Temporal Resolutions

• Rim enhancement

• Spiculated/smooth

• Focal/lobular

10

15

20

25

30

35

40

45

0 1 2 3 4 5 6 7 8 9

Time( min)

Intensity

High spatial resolution

High temporal resolution

Page 3: A novel technique has been proposed for dynamic MRI: Dynamic KWIC Permits image reconstruction at both high spatial and high temporal resolutions Technique.

KWIC Data Acquisition and Reconstruction

kx

ky

A

C

B

AB

A

B

D

C D

C

D

k

* Song, et al. MRM 44:825-832 (2000).

KWIC* = K-space Weighted Image Contrast

Conventional projection reconstruction MRI acquires data that lie along radial lines in k-space (a). The inset figure shows the region surrounding the center of k-space. Within the k-space "pixel" (dashed box), there is a high degree of oversampling. (b) In KWIC, the central region of k-space is occupied only by select views of interest (e.g., a single echo time in radial FSE, or a narrow temporal window in dynamic imaging). The adjacent annular region(s) of k-space is occupied by adjacent echoes or adjacent time frame.

Page 4: A novel technique has been proposed for dynamic MRI: Dynamic KWIC Permits image reconstruction at both high spatial and high temporal resolutions Technique.

Dynamic KWIC Image Acquisition & Reconstruction

512x384, 460µm

Dynamic KWIC

* Song, et al. MRM 52:815-824 (2004).

In conventional DCE-MRI, long scan times are required to achieve high spatial resolution. Top: Four high resolution images, each requiring 2:00 acquisition time. Bottom: Dynamic KWIC images, where each high resolution data set was acquired in 8 underdsampled passes. The effective temporal resolution for each high-resolution image is 15 sec.

Page 5: A novel technique has been proposed for dynamic MRI: Dynamic KWIC Permits image reconstruction at both high spatial and high temporal resolutions Technique.

DCE-MRI with and without KWIC processing

15 sec/image; 512x48; 470µm

15 sec/image; 128x48; 1.9mm

Dynamic KWIC

15 sec/image; 470µm

Low SNR

Low spatial resolution

High SNR and high spatial resolution

Page 6: A novel technique has been proposed for dynamic MRI: Dynamic KWIC Permits image reconstruction at both high spatial and high temporal resolutions Technique.

Parametric Maps

Peak enhancement Time to maximum slope Wash-out rate

QuickTime™ and aTIFF (LZW) decompressor

are needed to see this picture.

QuickTime™ and aTIFF (LZW) decompressor

are needed to see this picture.

Pre-contrast Post-contrast

Page 7: A novel technique has been proposed for dynamic MRI: Dynamic KWIC Permits image reconstruction at both high spatial and high temporal resolutions Technique.

Conclusions

• With angle-interleaved PR acquisition and temporally selective data filtering, both high temporal and high spatial resolutions can be achieved simultaneously.

• The dynamic KWIC technique may be useful in various applications, including dynamic contrast-enhancement studies, hyperpolarized gas imaging, cardiac motion, and kinematic studies involving object motion.

Page 8: A novel technique has been proposed for dynamic MRI: Dynamic KWIC Permits image reconstruction at both high spatial and high temporal resolutions Technique.

Principal Component Analysis of Undersampled Radial Data

QuickTime™ and aTIFF (LZW) decompressor

are needed to see this picture.

QuickTime™ and aTIFF (LZW) decompressor

are needed to see this picture.

PCA

PCA can be used to analyze the dynamic time series of the undersampled radial data series. Components that primarily contribute to image streaking and noise are rejected, while those that contain information of the tumor are maintained.

Undersampled dynamic series

PCA processed series

Low SNRStreaks

Higher SNRReduced streaks

Page 9: A novel technique has been proposed for dynamic MRI: Dynamic KWIC Permits image reconstruction at both high spatial and high temporal resolutions Technique.

Principal Component Analysis of Undersampled Radial Data

QuickTime™ and aTIFF (LZW) decompressor

are needed to see this picture.

QuickTime™ and aTIFF (LZW) decompressor

are needed to see this picture.

QuickTime™ and aTIFF (LZW) decompressor

are needed to see this picture.

QuickTime™ and aTIFF (LZW) decompressor

are needed to see this picture.

QuickTime™ and aTIFF (LZW) decompressor

are needed to see this picture.

Figure 1 Results from PCA processing of undersampled radial data set(a) Full dataset image: 512 points x 384 views (2 min acquisition). (b) Magnified and cropped image of (a).(c) Image from a single pass: 512 points x 48 views (15 sec).(d) PCA processed: 512 points x 48 views (15 sec).(e) Parametric map: RED = Signal wash-out, BLUE = Plateau.

a

b c ed