VWR ® FOR SIEVING Test sieve shakers and accessories Ultrasonic sieving systems Sample splitters Test sieves Standards Ultrasonic baths Useful accessories P:1800 008 453 | www.bio-strategy.com E: [email protected]Available from VWR Products are sold exclusively at Bio-Strategy in Australia and New Zealand
29
Embed
VWR FOR SIEVING...VWR FOR SIEVING | WR 11 Test sieves Frame: Stainless steel; woven wire cloth: Stainless steel, ISO 3310, ASTM E11, BS 410, AFNOR Ø (mm) Height (mm) Mesh size (mm)
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
VWR Products are sold exclusively at Bio-Strategy in Australia and New Zealand
A re-certification service is also available, please contact your local VWR sales office.
10 VWR | VWR® FOR SIEVING
Control of measuring instruments and inspection certificates for VWR test sieves
EN ISO 9000 ff. standard requires measuring instruments to be inspected at regular intervals. This also includes test sieves that are used as measuring instruments.
VWR offers you the opportunity to examine test sieves by using a computerised video analysis system at the manufacturers’ works laboratory or on-site. During the inspection, aperture sizes are measured and recorded in warp and weft direction. Statistical analysis is then used to verify the quality of the test sieve.
Following inspection, test sieves receive a seal. For each inspected test sieve, the customer obtains an Inspection Certificate 3.1 according to EN 10204 showing the distribution of aperture widths in graphic (for test sieve cloth only) and tabular form, as quality assurance documentation.
Test sieves are inspected by specially skilled people at the manufacturer’s factory using a calibrated computerised video analysis system. The ‘Materialprüfungsanstalt für das Bauwesen, Institut für Baustoffe, Massivbau und Brandschutz (MPA IBMP TU Braunschweig) Institute’ confirms that the manufacturer’s measuring device corresponds to ISO 3310-1:2000 (5.2, Test Methods Test 3) and ASTM E 11-01 (‘Test methods for checking wire cloth and testing sieves’) to determine whether they conform to specification. The manufacturer’s calibration method guarantees traceability to the national measuring standard.
CERTIFICATES
DIN EN 10 204Certificate of Compliance with the Standard 2.1
Werksbescheinigung 2.1Attestion de conformité à la norme 2.1
TEST SIEVE ANALYSENSIEB TAMIS DE CONTROLEDIN ISO 3310, NF ISO 3310, ISO 565, ASTM E11, BS 410
Aperture width / Nennweite / Ouverture w:
Manufactured in compliance with the quality assurance instructions according to ISO 9001. The test sieve tolerances
coincide with the standard of the test sieve label.
Hergestellt unter Einhaltung der Vorgaben für die Qualitätssicherung nach ISO 9001. Das Analysensieb
entspricht in seinen Toleranzen dem auf dem Typenschild genannten Standard.
Fabriqué en conformité avec les critères de la norme ISO 9001. Le tamis de contrôle répond aux critères de la norme figurant
sur la plaque.
Serial No. Date
Aperture width / Nennweite / Ouverture w:
Maintenance of Test SievesSee ISO 2591-1, DIN 66165, Part 1 and Part 2Test Sieves with apertures of 500 µm and smaller should be cleaned in an ultrasonic bath. After ultrasonic cleaning rinse the test sieve with clear water and blow out the sieve bottom with compressed air. Let the water drip for about 5 minutes and dry the test sieve at 80 - 100 °C max. for about 30 minutes.Remove any remaining particles from the surface of the mesh by tapping the test sieve frame slightly against a rubber or wooden pad. Never remove particles by brushing.
Behandlung von AnalysensiebenSiehe auch DIN 66165, Teil 1 und Teil 2 sowie ISO 2591-1 Analysensiebe mit Maschenweiten von 500 µm und feiner müssen im Ultraschallbad gereinigt werden. Nach dem Ultraschallbad mit klarem Wasser nachspülen und Siebboden mit Druckluft streifen-frei ausblasen, ca. 5 Minuten abtropfen und ca. 30 Minuten bei max. 80 -100 °C trocknen lassen.Noch vorhandene eingeklemmte Grenzkörner durch leichtes Klopfen des Analysensiebrahmens gegen eine Holz- oder Gummiunterlage entfernen. Keine Bürsten oder Pinsel benutzen.
Entretien des tamis de contrôleVoir ISO 2591-1 et DIN 66165, 1ère et 2ème partieLes tamis de contrôle ayant des ouvertures de maille inférieures à 500 µm doivent être nettoyés dans un bain à ultra-sons.Après nettoyage, il faut les rincer à l´eau claire et souffler de l´air comprimé sur toute la surface du tamis. Ensuite, égoutter pendant environ 5 minutes et laissez sécher environ 30 minutes à 80°-100°C. Si des particules sont restées coincées dans les mailles, il est possible de les déloger en frappant doucement le tamis contre un support en bois ou en caoutchouc. Ne jamais utiliser de brosse ou de pinceau dans ce but.
1.
Standard Certificate of Compliance 2.1
The metal cloth for test sieves and the test
sieve itself are manufactured to current
standards. Manufacturing is subject to our
quality assurance system certified
according to EN ISO 9001-2000.
Each VWR test sieve is delivered with a
Certificate of Compliance with Order 2.1
according to EN 10204 as standard.
2. Optional Inspection Certificate or Calibration Certificate 3.1
VWR test sieves can be supplied with an Inspection Certificate or Calibration Certificate
3.1 according to EN 10204 with measuring results of a specific test.
Both methods carry out measurement in warp and weft direction. They differ in the
quantity of the measured aperture widths, resulting in different confidence levels.
During a ‘calibration’ three times as many aperture widths are measured compared to
during a ‘certification’. In general the test sieve is subject to a specific inspection.
Aperture widths are stated for warp and weft direction. The results are recorded for
further control measurements.
11VWR FOR SIEVING | VWR
Test sievesFrame: Stainless steel; woven wire cloth: Stainless steel, ISO 3310, ASTM E11, BS 410, AFNOR
Delivery information: Supplied as standard with a certificate of compliance 2.1 according to DIN EN 10204.
Optional: Inspection certificate of calibration 3.1 according to DIN EN 10204 with measuring results of a specific test.
Sieves and accessories of other dimensions are available on request. Please go to www.vwr.com for a full overview.
All sieves are supplied with serial number and a certificate of compliance with the order 2.1 according to DIN EN 10204. Further certificates and calibration services are available. Contact your local VWR sales office for further details.
12 VWR | VWR FOR SIEVING
Test sieves
Description Ø (mm) Height (mm) Pk Cat. No.AccessoriesSieve cover 76 - 1 510-3662Sieve pan 76 22 1 510-3663Calibration certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 203 mm - - 1 510-1237Inspection certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 203 mm - - 1 510-1240
Description Ø (mm) Height (mm) Pk Cat. No.AccessoriesSealing ring, PVC 100 - 1 510-3666Sieve cover 100 - 1 510-3664Sieve pan 100 30 1 510-3665Calibration certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 203 mm - - 1 510-1237Inspection certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 203 mm - - 1 510-1240
Description Ø (mm) Height (mm) Pk Cat. No.AccessoriesSealing ring, PVC 150 - 1 510-3671Sieve cover 150 - 1 510-3669Sieve pan 150 50 1 510-3670Calibration certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 203 mm - - 1 510-1237Inspection certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 203 mm - - 1 510-1240
Description Ø (mm) Height (mm) Pk Cat. No.AccessoriesIntermediate pan (sieve frame with solid base) 200 32 1 510-3677Intermediate ring (sieve frame without base) 200 32 1 510-3679Sealing ring, PVC 200 - 203 - 1 510-3680Sealing ring, Viton (-15 up to +200 °C) 200 - 203 - 1 510-3681Sieve cover 200 - 1 510-3672Sieve pan 200 32 1 510-3674Calibration certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 203 mm - - 1 510-1237Inspection certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 203 mm - - 1 510-1240
Description Ø (mm) Height (mm) Pk Cat. No.AccessoriesIntermediate pan (sieve frame with solid base) 200 50 1 510-3676Intermediate ring (sieve frame without base) 200 50 1 510-3678Sealing ring, PVC 200 - 203 - 1 510-3680Sealing ring, Viton (-15 up to +200 °C) 200 - 203 - 1 510-3681Sieve cover 200 - 1 510-3672Sieve pan 200 50 1 510-3673Sieve pan with discharge nozzle 200 50 1 510-3675Calibration certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 203 mm - - 1 510-1237Inspection certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 203 mm - - 1 510-1240
Description Ø (mm) Height (mm) Pk Cat. No.AccessoriesIntermediate pan (sieve frame with solid base) 203 32 1 510-3687Intermediate ring (sieve frame without base) 203 32 1 510-3689Sealing ring, PVC 200 - 203 - 1 510-3680Sealing ring, Viton (-15 up to +200 °C) 200 - 203 - 1 510-3681Sieve cover 203 - 1 510-3682Sieve pan 203 32 1 510-3684Calibration certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 203 mm - - 1 510-1237Inspection certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 203 mm - - 1 510-1240
Description Ø (mm) Height (mm) Pk Cat. No.AccessoriesIntermediate pan (sieve frame with solid base) 203 50 1 510-3686Intermediate ring (sieve frame without base) 203 50 1 510-3688Sealing ring, PVC 200 - 203 - 1 510-3680Sealing ring, Viton (-15 up to +200 °C) 200 - 203 - 1 510-3681Sieve cover 203 - 1 510-3682Sieve pan 203 50 1 510-3683Sieve pan with discharge nozzle 203 50 1 510-3685Calibration certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 203 mm - - 1 510-1237Inspection certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 203 mm - - 1 510-1240
Description Ø (mm) Height (mm) Pk Cat. No.AccessoriesIntermediate ring (sieve frame without base) 250 55 1 510-1232Sieve cover 250 - 1 510-1229Sieve pan 250 55 1 510-1230Sieve pan with discharge nozzle 250 50 1 510-1231Calibration certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 315 mm - - 1 510-1238Inspection certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 315 mm - - 1 510-1241
Description Ø (mm) Height (mm) Pk Cat. No.AccessoriesIntermediate ring (sieve frame without base) 300 30 1 510-3695Sealing ring, PVC 300 - 305 - 1 510-3696Sealing ring, Viton (-15 up to +200 °C) 300 - 305 - 1 510-3697Sieve cover 300 - 1 510-3690Calibration certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 315 mm - - 1 510-1238Inspection certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 315 mm - - 1 510-1241
Description Ø (mm) Height (mm) Pk Cat. No.AccessoriesIntermediate pan (sieve frame with solid base) 300 60 1 510-3693Intermediate ring (sieve frame without base) 300 60 1 510-3694Sealing ring, PVC 300 - 305 - 1 510-3696Sealing ring, Viton (-15 up to +200 °C) 300 - 305 - 1 510-3697Sieve cover 300 - 1 510-3690Sieve pan 300 60 1 510-3691Sieve pan with discharge nozzle 300 60 1 510-3692Calibration certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 315 mm - - 1 510-1238Inspection certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 315 mm - - 1 510-1241
Description Ø (mm) Height (mm) Pk Cat. No.AccessoriesIntermediate ring (sieve frame without base) 305 60 1 510-3701Sieve cover 305 - 1 510-3698Sieve pan 305 60 1 510-3699Sieve pan with discharge nozzle 305 60 1 510-3700Calibration certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 315 mm - - 1 510-1238Inspection certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 315 mm - - 1 510-1241
Description Ø (mm) Height (mm) Pk Cat. No.AccessoriesIntermediate ring (sieve frame without base) 315 75 1 510-1236Sieve cover 315 - 1 510-1233Sieve pan 315 75 1 510-1234Sieve pan with discharge nozzle 315 75 1 510-1235Calibration certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 315 mm - - 1 510-1238Inspection certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 315 mm - - 1 510-1241
Description Ø (mm) Height (mm) Pk Cat. No.AccessoriesIntermediate ring (sieve frame without base) 350 60 1 510-3705Sealing ring, PVC 350 - 1 510-3706Sealing ring, Viton (-15 up to +200 °C) 350 - 1 510-3707Sieve cover 350 - 1 510-3702Sieve pan 350 60 1 510-3703Sieve pan with discharge nozzle 350 60 1 510-3704Calibration certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 400 mm - - 1 510-1239Inspection certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 400 mm - - 1 510-1242
Description Ø (mm) Height (mm) Pk Cat. No.AccessoriesIntermediate pan (sieve frame with solid base) 400 60 1 510-3711Intermediate ring (sieve frame without base) 400 60 1 510-3712Sealing ring, PVC 400 - 1 510-3713Sealing ring, Viton (-15 up to +200 °C) 400 - 1 510-3714Sieve cover 400 - 1 510-3708Sieve pan 400 65 1 510-3709Sieve pan with discharge nozzle 400 65 1 510-3710Calibration certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 400 mm - - 1 510-1239Inspection certificate 3.1 according to EN 10204 (together with initial order of sieve). Up to 400 mm - - 1 510-1242
Delivery information: Supplied as standard with a certificate of compliance 2.1 according to DIN EN 10204.
Optional: Inspection certificate of calibration 3.1 according to DIN EN 10204 with measuring results of a specific test.
Sieves and accessories of other dimensions are available on request. Please go to www.vwr.com for a full overview.
All sieves are supplied with serial number and a certificate of compliance with the order 2.1 according to DIN EN 10204. Further certificates and calibration services are available. Contact your local VWR sales office for further details.
Model Star BeaterMax. sample volume (ml) 2×50Vibrational frequency (Hz) 3 - 30Speed display LEDGrinding time setting (min) 5 s to 60 minPower consumption (W) 200 VAW×D×H (mm) 365×405×225Weight (kg) 42
Mixer mill, Star BeaterA ball mill for disintregration of small sample volumes that can also be used to shake/mix microtubes and microplates. Wide range of applications in different scientific fields from geology to biotechnology.
• Easy to use - simple knob and keypad to control frequency and timer• Easy to maintain - brushless DC motor• Large range of grinding jars and tube holders to suit the sample
Description Pk Cat. No.AccessoriesTube holder, PTFE for reaction vials, 12×0,2 ml tubes on each arm 1 412-0181Tube holder, PTFE for reaction vials, 12×2 ml tubes on each arm 2 412-0182Tube holder, PTFE for reaction vials, 6×2 ml tubes on each arm 2 412-0183Tube holder, PTFE for reaction vials, 6×2 ml tubes (screw cap) on each arm 2 412-0184Holder, PTFE, for up to 3 microplates or 1 deep well plates on each arm 2 412-0185Rack, PTFE, for 24x 1,5/2,0 ml tubes (with or without screw cap) 2 412-0199Dummy plate, PTFE, for replacing one microtitre plate in the rack 2 412-0200Rack , PTFE, 50 ml with 5 places for conical tubes 2 412-0212Set of spanners 1 SET 412-0180Holder for 15 ml falcon tubes 2 412-0263Holder for up to 3 microplates or 1 deep well plates on each arm 2 412-0272
33VWR FOR SIEVING | VWR
Capacity (ml) W×D×H (mm) Colour Pk Cat. No.Standard7 46×46×8 Blue 500 611-91687 46×46×8 Black 500 611-91757 46×46×8 White 500 611-0093100 85×85×24 Blue 500 611-9169100 85×85×24 Black 500 611-9176100 85×85×24 White 500 611-0094250 140×140×22 Blue 500 611-9170250 140×140×22 Black 500 611-9177250 140×140×22 White 500 611-0095Anti-static7 46×46×8 Blue 500 611-31137 46×46×8 Black 500 611-91817 46×46×8 White 500 611-9178100 85×85×24 Blue 500 611-3114100 85×85×24 Black 500 611-9182100 85×85×24 White 500 611-9179250 140×140×22 Blue 500 611-3115250 140×140×22 Black 500 611-9183250 140×140×22 White 500 611-9180
Disposable weighing boatsPS, square
These flexible weighing boats, with smooth surfaces, enable accurate pour-out with minimal sample loss. They are biologically inert and resistant to dilute and weak acids, aqueous solutions, alcohols and bleaches. Ideal for use with microwaves, balances or moisture analysers.
• Shallow form with wide, flat bottom avoids tipping• Rounded corners simplify transfer• Temperature resistant up to +70 °C
34 VWR | VWR FOR SIEVING
Useful accessories
Description W×D×H (mm) Colour Pk Cat. No.FSC® Certified 35×35×15 White 500 611-3258FSC® Certified 35×35×15 Brown 500 611-3256FSC® Certified 45×45×15 White 500 611-3259FSC® Certified 45×45×15 Brown 500 611-3257FSC® Certified 92×92×25 White 250 611-3625FSC® Certified 92×92×25 Brown 250 611-3624
Weighing boats, paperVWR® paper weighing boats are a first in eco friendly laboratory consumables.
• Control contents like a polystyrene weighing boat making them easier to handle than standard, flat weighing paper
• Made of greaseproof paper that meets FDA 21 CFR 176.170, components of paper in contact with aqueous and fatty foods, with 2I CFR 176.180 and contact with dry foods
• Compatible with heat applications up to a maximum of 210 ºC
They are both Eco-In and Eco-Out.Eco-In because they are FSC® Certified. The papers used to manufacture our boats are made from responsibly forested wood products.Eco-Out because they are naturally biodegradable in the standard municipal waste stream.
Description Capacity (ml) I-Ø×H (mm) Pk Cat. No.Disposable smooth-walled aluminium weighing dishes Smooth-sided, flat bottom, multipurpose ‘utility’ dish. 30 57×16 100 611-3658Smooth-sided, flat bottom, multipurpose ‘utility’ dish. 80 70×16 100 611-1380Smooth-sided, flat bottom, multipurpose ‘utility’ dish. 140 103×19 100 611-3659Disposable aluminum weighing/drying pansWeighing pan, ideal for general purpose weighing and dispensing. Compatible with both open and enclosed balances with a small weighing area (70 - 95 mm).
40 70×6,3 50 611-1354
Weighing/drying pan, ideal for general purpose weighing, dispensing, storage and drying. Compatible with Mettler, Sartorius, AND, Denver Instruments.
60 102×7,9 50 611-1353
Flat-top balance pan. Compatible with Ohaus balances and moisture analysers or any flat top balance. 50 127×54,8 100 611-1350Disposable aluminium drying pans for solids/liquidsDrying pan for solids (compatible with Cenco moisture analyser). 30 110×9,5 25 611-1351Drying pan for liquids (compatible with Cenco moisture analyser). 50 110×7,9 25 611-1352
Disposable weighing and drying dishes or pans
611-1354, 611-1350 & 611-1353 611-1351 & 611-1352
611-1380, 611-3658 & 611-3659
Dishes and pans, made of aluminium.
• Compatible with most balances and dryers • Oil-free • Slightly tapered for easy stacking
Sturdy, disposable dishes and pans. Ideal for general purpose weighing, dispensing, storage and drying applications.
Sampling spoonsPS, white. These disposable spoons are produced in a cleanroom environment and gamma radiation sterilised. They are ideal for the sampling of powder, granules and pastes.
• Available in two different sizes: 2,5 ml (similar to a teaspoon) and 10 ml (similar to a tablespoon)
• Production, assembling and packaging according to cleanroom Class 7 (10 000)
• According to EU food and FDA guidelines• Individually packed, gamma radiation sterilised
Capacity (ml) Length (mm) Colour Pk Cat. No.50 160 White 100 231-0490150 216 White 100 231-0491
Sampling scoopsPS, white. These sterile scoops are ideal for the sampling of powder, granules and pastes.
• Production, assembling and packaging according to cleanroom Class 7 (10 000)
• According to EU food and FDA guidelines• Individually packed, gamma radiation sterilised
Thanks to the special handle construction, and the slightly angled edge, the scoop stands horizontally and can be laid down without the material trickling out.
Spatulas, disposablePP. Multipurpose, robust, inexpensive tools for collecting, transferring and processing samples of chemical and biological materials.
• Resistant to dilute acids and alkalis • Reduce cross-contamination • Autoclavable• Compliant with FDA standards for applications involving contact with food
The innovative shape of these spatulas allows them to be used as a spatula, spoon, scoop, scraper, mixing rod or for wiping. Ideal for recovering samples that have been frozen in liquid nitrogen. The macro type disposable spatulas are 50% larger than standard disposable spatulas. The long shaft makes it easier to transfer material from larger containers.
3VWR FOR SIEVING | VWR
Test sieve shakers, EML 200 seriesVWR by Haver & Boecker
The EML 200 series offers different types of units. All models are suitable for 50 to 203 mm Ø sieves, a maximum sample/batch load of 3 kg, have a cast aluminium housing and improved clamping system.
• Digital timer: 0 to 99 minutes or constant operation• All shakers have a cover with inspection glass
which allows samples to be viewed during sieving
EML 200 Pure units which are ideal for standard analysis:Feature two given regulated amplitudes to select from: Fine or coarseOperation in set intervals of 10 secondsClassic ‘eco’ clamping system
EML 200 Premium units are suitable for users requiring precise and reproducable sieve analyses:Extra quiet electromagnetic driveFreely selectable amplitudes up to 3 mmExtra large, easy to use display and simple logical operationDuring sieving the remaining sieving time is shown on the displayUp to 49 different sieving programs can be stored in the memoryOption of Classic or HAVER TwinNut® quick release clamping system
EML 200 Premium Remote models also offer wet sieving, features as Premium units.Integrated full cone nozzleSeparate controller which can be wall mounted
Ordering information: Acceptance test certificate 3.1 according to DIN EN 10204 and IQ/OQ documentation for are available as optional accessories for all models, for details please contact your local VWR sales office.
Description Application Pk Cat. No.EML200 Pure modelsEML 200 Pure with Classic ‘eco’ clamping system, EU-plug Dry sieving 1 VWRI550106EUEML200 Premium modelsEML 200 Premium with Classic clamping system, EU-plug Dry sieving 1 VWRI550109EUEML 200 Premium with HAVER TwinNut® quick clamping system, EU-plug Dry sieving 1 VWRI550108EUEML 200 Premium Remote modelsEML 200 Premium Remote with Classic clamping system, EU-plug Wet/dry sieving 1 VWRI550112EUEML 200 Premium Remote with HAVER TwinNut® quick clamping system, EU-plug Wet/dry sieving 1 VWRI550111EU
Description Application Pk Cat. No.AccessoriesKnurled nut for Classic ‘eco’ clamping system EML Pure 1 HAVE560275Guide rod for Classic ‘eco’ clamping system EML Pure 1 HAVE560276Full cone nozzle EML Premium Remote 1 HAVE560278Cover with inspection glass EML Premium and EML Pure 1 HAVE560283over with full cone nozzle and inspection glass EML Premium Remote (for wet sieving) 1 HAVE560285
4 VWR | VWR FOR SIEVING
Test sieve shakers and accessories
Test sieve shakers, EML digital plus VWR by Haver & Boecker
These electromagnetically-driven test sieve shakers are designed for sieve analysis with optimum three-dimensional sieving action. The self-re-adjusting amplitude, which uses permanent acceleration measurement of the whole sieve tower, balances the oscillation of the shaker and its stand. This guarantees that amplitude stays the same, irrespective of the feed quantity and the installation position.
• Memory for 10 test sieve parameter sets• Timer function: 0 - 99 minutes or continuous operation• Intermittent or continuous shaking operation• Digital display of all functions• 3000 impulses per minute (50 Hertz)• Sound emission: ≤70 dB(A) for EML 315 digital plus, EML 450 digital
plus: 73 dB(A)• Maximum loading: 21 kg for EML 315 (6 kg sieved material), 42 kg
for EML 450 (15 kg sieved material)
EML 315 and 450 models are for dry and wet sieving and have a separate control device.
EML 315 digital plus N
EML 450 digital plus NEML 450 digital plus T
Optional HAVER ‘TwinNut’ the quick-release clamping system:
’TwinNut’ clamps for easy fixing and removal of the cover are an alternative to the standard ‘Classic’ knurled nuts. The guide rods of the ‘Classic’ system can also be used for the HAVER ‘TwinNut’ system.
Ordering information: Sieves and collecting pan must be ordered separately. IQ-OQ documentation on request.
Delivery information: Included as standard with each shaker: Models with either ‘Classic’ clamping system or ‘TwinNut’ system are supplied with two guide rods (660 mm for EML 200 and EML 315; 850 or 1000 mm for EML 450) and two knurled nuts with handlebars, cover with inspection glass and water spray diffuser for wet sieving models.
Application Type Pk Cat. No.EML 315 digital plus with ‘Classic’ clamping system, for sieves up to 315 mm ØDry sieving EML 315 digital plus T, EU-plug 1 VWRI550061EUWet sieving EML 315 digital plus N, EU-plug 1 VWRI550063EUEML 315 digital plus with ‘TwinNut’ quick-release clamping system, for sieves up to 315 mm ØDry sieving EML 315 digital plus T with ‘TwinNut’ quick-release clamping system, EU-plug 1 VWRI550084EUWet sieving EML 315 digital plus N with ‘TwinNut’ quick-release clamping system, EU-plug 1 VWRI550085EUEML 450 digital plus with ‘Classic’ clamping system, for sieves up to 450 mm ØDry sieving EML 450 digital plus T, EU-plug 1 VWRI550064EUWet sieving EML 450 digital plus N, EU-plug 1 VWRI550065EU
5VWR FOR SIEVING | VWR
Description For Pk Cat. No.AccessoriesGuide rod, length 850 mm (one only) EML 450 digital plus/UWL 400 1 510-0976Knurled nut with two handlebars (one only) EML 450 digital plus/UWL 400 1 510-0977Cover with inspection glass (test sieve diameter 300/305/315/350/400 and 450 mm) EML 450 digital plus 1 510-0992Cover with wide spreading spray diffuser (for wet sieving test sieve diameter 300/305/350/400 and 450 mm) EML 450 digital plus 1 510-0993Additional weight for extra stability for test sieve diameter 200 - 450 mm (27 kg) EML 450 digital plus 1 510-0994Reduction piece, polyamide, to receive a sieve pan with diameter 400 mm under larger sieves EML 450 digital plus 1 510-0996Cover with inspection glass (test sieve diameter only for >300 mm) EML 315 digital plus 1 510-0998Cover with wide spreading spray diffuser (for wet sieving test sieve diameter only for >300 mm) EML 315 digital plus 1 510-0999Cover with wide spreading spray diffuser (for wet sieving test sieve diameter only for >300 mm) EML 315 digital plus 1 510-1001Cover with wide spreading spray diffuser (for wet sieving test sieve diameter only for >300 mm) EML 315 digital plus 1 510-1002Cover with inspection glass (test sieve diameter only for >300 mm) EML 315 digital plus 1 510-1003Cover with inspection glass (test sieve diameter only for >300 mm) EML 315 digital plus 1 510-1004Reduction piece, polyamide, to receive a sieve pan with discharge nozzle, diameter 200 mm EML 315 digital plus 1 510-1252Sound absorbing cupboard EML 315 digital plus 1 510-1311Sound absorbing cupboard EML 450 digital plus/UWL 400 1 510-1312Inspection glass without centre hole (to be mounted on the cover) EML 450 digital plus/UWL 400 1 510-1010Guide rod, length 1000 mm (one only) EML 450 digital plus/UWL 400 1 510-1016Reduction piece for cover, for sieve Ø 76 mm EML 200 1 510-1017Reduction piece for cover, for sieve Ø 100 mm EML 200 1 510-1009Reduction piece for cover, for sieve Ø 150 mm EML 200 1 510-1013Reduction piece for cover, for sieve pan with discharge nozzle <400 mm EML 450 1 510-0997Inspection glass with central hole EML 200/EML 315 1 510-1018Inspection glass with central hole EML 450/UWL 400 1 510-1014
Description For Pk Cat. No.
IQ/OQ documentationEML 200 digital plus, EML 315 digital plus and EML 450 digital plus sieve shakers
1 510-1246
IQ-OQ documentation for VWR-HAVER sieve shakersVWR by Haver & Boecker
IQ/OQ documentation to assist with GLP compliance.
Application Type Pk Cat. No.EML 450 digital plus with ‘TwinNut’ quick-release clamping system, for sieves up to 450 mm ØDry sieving EML 450 digital plus T with ‘TwinNut’ quick-release clamping system, EU-plug 1 VWRI550087EUWet sieving EML 450 digital plus N with ‘TwinNut’ quick-release clamping system, EU-plug 1 VWRI550088EU
7VWR FOR SIEVING | VWR
Sieve shakers, heavy duty, UWLHaver & Boecker
For test sieves up to 400 mm diameter or square sieves up to 500×500 mm
The UWL 400 is an efficient test sieve shaker and achieves optimum results for large feed quantities. It creates a three-dimensional sieving action and is especially designed for coarse grained products. The UWL 400 T is suitable for dry sieving; the UWL 400 N is suitable for wet sieving, and the UWL 400 H is suitable for square test sieves with beechwood frames.
• Separate control device, wall fixing possible• Rotation speed: 1500 min-1
• Timer function: 0 - 599 minutes• Max. loading: 50 kg (20 kg sieving material)• Sound emission: 70 dB(A)
Delivery information: Included as standard with each shaker: Models with either ‘Classic’ clamping system or HAVER ‘TwinNut’ system are supplied with 2×620 mm guide rods and two knurled nuts with handlebars, cover with inspection glass, water spray diffuser for wet sieving on model UWL 400 N and special appliance for beechwood frames on UWL 400 H model.
Application Type Pk Cat. No.UWL heavy duty sieve shakersDry sieving UWL 400 T, EU-plug 1 HAVE550404EUDry sieving with square sieves UWL 400 H, EU-plug 1 HAVE550473EUWet sieving UWL 400 N, EU-plug 1 HAVE550480EUUWL heavy duty sieve shakers with HAVER ‘TwinNut’ quick-release clamping systemDry sieving UWL 400 T with HAVER ‘TwinNut’ quick-release clamping system, EU-plug 1 HAVE550080EUWet sieving UWL 400 N with HAVER ‘TwinNut’ quick-release clamping system, EU-plug 1 HAVE550081EU
For dividing sieved material into representative test sieve samples.
Type RT 6,3 and 12,5
Consists of 1 lacquered sheet steel rack, 300×250×270 mm, 1 stainless steel divider and 3 receivers which are tin sheet (1,75 litres) or laminated plastic (2 litres).
Type RT 25; 37,5; 50 and 75
Consists of 1 rack 620×260×420 mm, 1 divider and 3 receivers with grab handles (8 litres), all of galvanised steel.
Description Type Pk Cat. No.Type RT 6,3 and 12,512 partitions of 6,3 mm, 1,75 l tin sheet receivers RT 6,3 1 510-049212 divisions of 6,3 mm, 2 l laminated plastic receivers RT 6,3 1 510-049418 partitions of 12,5 mm, 1,75 l tin sheet receivers RT 12,5 1 510-049118 partitions of 12,5 mm, 2 l laminated plastic receivers
RT 12,5 1 510-0493
Description Type Pk Cat. No.Type RT 25, 37,5, 50 and 7516 partitions of 25 mm RT 25 1 510-049012 partitions of 37,5 mm RT 37,5 1 510-04898 partitions of 50 mm RT 50 1 510-04886 partitions of 75 mm RT 75 1 510-0487
Description For Pk Cat. No.AccessoriesDivider, stainless steel, 12 divisions, 6,3 mm Sample splitter RT 6,3 1 510-0944Divider, stainless steel, 18 divisions, 12,5 mm Sample splitter RT 12,5 1 510-0499Divider, galvanised sheet steel, 16 divisions, 25 mm Sample splitter RT 25 1 510-0497Divider, galvanised sheet steel, 12 divisions, 37,5 mm Sample splitter RT 37,5 1 510-0943Divider, galvanised sheet steel, 8 divisions, 50 mm Sample splitter RT 50 1 510-0496Divider, galvanised sheet steel, 6 divisions, 75 mm Sample splitter RT 75 1 510-0942Rack, lacquered sheet steel, 300×250×270 mm Sample splitters RT 6,3 and RT 12,5 1 510-0498Rack, galvanised sheet steel, 620×260×420 mm Sample splitters RT 25, RT 37,5, RT 50 and RT 75 1 510-0495Receiver, tin sheet, 1,75 litres Sample splitters RT 6,3 and RT 12,5 1 510-1261Receiver with grab handles, galvanised sheet steel, 8 l Sample splitters RT 25, RT 37,5, RT 50 and RT 75 1 510-1263