Top Banner
UC Copper / Fibre summary on USPs Zoran Borcic, Axel Koplev
23

UC Copper / Fibre summary on USPs...MMS Multimedia Solutions | Introduction | MAR 2014 13 UC Copper Range Shielded solutions Focus on Cat. 6A / 7/ 7A Prepare for Cat.8 / 40G Patent

Oct 01, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: UC Copper / Fibre summary on USPs...MMS Multimedia Solutions | Introduction | MAR 2014 13 UC Copper Range Shielded solutions Focus on Cat. 6A / 7/ 7A Prepare for Cat.8 / 40G Patent

UC Copper / Fibresummary on USPs

Zoran Borcic, Axel Koplev

Page 2: UC Copper / Fibre summary on USPs...MMS Multimedia Solutions | Introduction | MAR 2014 13 UC Copper Range Shielded solutions Focus on Cat. 6A / 7/ 7A Prepare for Cat.8 / 40G Patent

12MMS Multimedia Solutions | Introduction | MAR 2014

Draka UC Cable Key Elements

UC Copper Range

Shielded solutions

Focus on Cat. 6A / 7/ 7A

Prepare for Cat.8 /40G

Patent based design

Cat. 6 U/UTP HD

Cat. 6A U/FTP

Box solutions Cat. 6A/7

3P, Delta, GL, DNVapprovals

UCFIBRE

OM3 / OM4 BIMM

Fibre buffer ES9/LS9

Indoor, universal andoutdoor portfolio

Distribution style ,Break-out, Centraltube, Loose tubeCables

UCFUTURE

Compact / loomeddesign

High density

Green and safesolutions

Bend InsensitiveOM3/4

Flextube technology

MPO cables, High fibrecount data centrecable

Industrial platform: Fibre , OF cables, Category and Multimedia copper cables

Cable Materials: PE, PP, PBT, LSOH, Specials (PVC, PUR, Rubber)

Assessment: Fibre characteristics, shielding performance, fire performance - IEC, CPD

Draka UC = Universal Cabling

The brand for Datacom applications

Page 3: UC Copper / Fibre summary on USPs...MMS Multimedia Solutions | Introduction | MAR 2014 13 UC Copper Range Shielded solutions Focus on Cat. 6A / 7/ 7A Prepare for Cat.8 / 40G Patent

13MMS Multimedia Solutions | Introduction | MAR 2014

UC Copper Range

Shielded solutions

Focus on Cat. 6A / 7/ 7A

Prepare for Cat.8 / 40G

Patent based design

Cat. 6 U/UTP HD

Cat. 6A U/FTP

Box solutions Cat. 6A /7

3P, Delta, GL, DNVapprovals

UC Copper Cable Key Elements

UC400 Cat.6 U/UTP HD

4P = 4-pairs

23 = AWG 23 (Ø 0,57 mm)

AS = Special-Foilscreen around

2P(patent) + foilscreen

UC500 = Universal Cable 500 MHz

UC500 AS23Cat.6A4P

Category 6a

Page 4: UC Copper / Fibre summary on USPs...MMS Multimedia Solutions | Introduction | MAR 2014 13 UC Copper Range Shielded solutions Focus on Cat. 6A / 7/ 7A Prepare for Cat.8 / 40G Patent

14MMS Multimedia Solutions | Introduction | MAR 2014

Generic requirements and design elements of UCcopper data cables

Categorie 5e, RAL 7035

UC300 24 Cat.5e U/UTPU/UTP 0.51mm X IEC 61156-5 EN 50288-3-1 100 MHz 300 MHz

UC300 S24 Cat.5e F/UTPF/UTP 0.51mm X IEC 61156-5 EN 50288-2-1 100 MHz 300 MHz

UC300 HS24 Cat.5.e SF/UTPSF/UTP 0.51mm X IEC 61156-5 EN 50288-2-1 100 MHz 300 MHz

Categorie 6, RAL 5012

UC400 Cat.6 U/UTP HDU/UTP 0.54mm X IEC 61156-5 EN 50288-6-1 250 MHz 400 MHz

UC400 S23 Cat.6 U/FTPU/FTP 0.56mm X IEC 61156-5 EN 50288-5-1 250 MHz 400 MHz

UC400 HS23 Cat.6 S/FTPS/FTP 0.56mm X IEC 61156-5 EN 50288-5-1 250 MHz 400 MHz

Categorie 6A, RAL 5024

UC500 23 Cat.6A U/UTPU/UTP 0.60mm X IEC 61156-5 EN 50288-11 500 MHz 500 MHz

UC500 S23 Cat.6A U/FTPU/FTP 0.56mm X IEC 61156-5 EN 50288-10 500 MHz 500 MHz

UC500 AS23 Cat.6A F/FTPF/FTP 0.56mm X IEC 61156-5 EN 50288-10 500 MHz 500 MHz

Categorie 7, RAL 2003

UC900 HS23 Cat.7 S/FTPS/FTP 0.56mm X IEC 61156-5 EN 50288-4-1 600 MHz 900 MHz

UC900 SS23 Cat.7 S/FTPS/FTP 0.56mm X X IEC 61156-5 EN 50288-4-1 600 MHz 900 MHz

Categorie 7A + MULTIMEDIA, RAL 1028

UC1200 HS23 Cat.7A S/FTPS/FTP 0.58mm X IEC 61156-5 EN 50288-9-1 1000 MHz 1200 MHz

UC1200 SS23 Cat.7A S/FTPS/FTP 0.58mm X X IEC 61156-5 EN 50288-9-1 1000 MHz 1200 MHz

UC1500 HS22 Cat.7A S/FTPS/FTP 0.62mm X IEC 61156-5 EN 50288-9-1 1000 MHz 1500 MHz

UC1500 SS22 Cat.7A S/FTPS/FTP 0.64mm X X IEC 61156-5 EN 50288-9-1 1000 MHz 1500 MHz

UC MULTIMEDIA 1500 SS23 6FOILS S/FTPS/FTP 0.58mm X X IEC 61156-5 EN 50288-9-1 1000 MHz 1500 MHz

UC MULTIMEDIA 1500 SS22 6FOILS S/FTPS/FTP 0.64mm X X IEC 61156-5 EN 50288-9-1 1000 MHz 1500 MHz

Draka UC copper data installation cables

IEC 61156cable frequency

bandwith

Flame resistance

Product name Design Conductor IEC

60332-1

IEC

60332-3-24

EN50288System limit

frequnecy

Page 5: UC Copper / Fibre summary on USPs...MMS Multimedia Solutions | Introduction | MAR 2014 13 UC Copper Range Shielded solutions Focus on Cat. 6A / 7/ 7A Prepare for Cat.8 / 40G Patent

15MMS Multimedia Solutions | Introduction | MAR 2014

Space Saving

Compact, hence fit more

in a tray

Standard 90m link length

23 AWG conductor

Passes relevant ISO/IEC

& TIA standards with

good headroom

Ease of Handling

Flexible

Light weight

Reelex Box packaging

Retro-fit advantages

Diameter comparable to Cat5e

In most cases, use same containment as Cat5e

UC400 Cat.6 U/UTP HD

Page 6: UC Copper / Fibre summary on USPs...MMS Multimedia Solutions | Introduction | MAR 2014 13 UC Copper Range Shielded solutions Focus on Cat. 6A / 7/ 7A Prepare for Cat.8 / 40G Patent

16MMS Multimedia Solutions | Introduction | MAR 2014

Please choose the containment type:

Enter Tray W idth 200 mm

Enter Tray depth 30 mm

Please enter the cable diameter 6 mm

Please enter any future spare capacity for future %

(in percentage)

Maximum number of Cables

(based on the information above)

This spreadsheet is for inform ation only. Calculations based on relevant international standards V1.0 N ov'12

Cat6 U/UTP Standard

UC400 Cat.6 U/UTP HD

Page 7: UC Copper / Fibre summary on USPs...MMS Multimedia Solutions | Introduction | MAR 2014 13 UC Copper Range Shielded solutions Focus on Cat. 6A / 7/ 7A Prepare for Cat.8 / 40G Patent

17MMS Multimedia Solutions | Introduction | MAR 2014

Cat6 U/UTP HD

Please choose the containment type:

Enter Tray Width 200 mm

Enter Tray depth 30 mm

Please enter the cable diameter 5.3 mm

Please enter any future spare capacity for future %

(in percentage)

Maximum number of Cables 136(based on the information above)

This spreadsheet is for information only. Calculations based on relevant international standards V1.0 Nov'12

UC400 Cat.6 U/UTP HD

Page 8: UC Copper / Fibre summary on USPs...MMS Multimedia Solutions | Introduction | MAR 2014 13 UC Copper Range Shielded solutions Focus on Cat. 6A / 7/ 7A Prepare for Cat.8 / 40G Patent

18MMS Multimedia Solutions | Introduction | MAR 2014

+22%

UC400 Cat.6 U/UTP HD

Page 9: UC Copper / Fibre summary on USPs...MMS Multimedia Solutions | Introduction | MAR 2014 13 UC Copper Range Shielded solutions Focus on Cat. 6A / 7/ 7A Prepare for Cat.8 / 40G Patent

19MMS Multimedia Solutions | Introduction | MAR 2014

UC Cat.6A Cable Design Types

Description OD

UC500 23 AWG U/UTPUnshielded Twisted Pair

500mtReel

8.9mm

UC500 S23 AWG U/FTPUnscreened/ Foil Twisted Pair

305mt Box500mtReel

6.9mm

UC500 AS23 AWG F/FTPFoil shielded/ Foil Twisted Pair,drain wire

500mtReel

7.1mm

23 AWG S/FTPScreened (copper braid,tinned) / Foil Shielded TwistedPair

500mtReel

7.3 mm

Page 10: UC Copper / Fibre summary on USPs...MMS Multimedia Solutions | Introduction | MAR 2014 13 UC Copper Range Shielded solutions Focus on Cat. 6A / 7/ 7A Prepare for Cat.8 / 40G Patent

20MMS Multimedia Solutions | Introduction | MAR 2014

Cat.6A (10G) Unshielded vs. Shielded

Positive:

No ANEXT issues, nomeasurement if couplingattenuation > 55dB

No EMC Issues

Smaller OD cables than theUTP offering

Can mix and match cablingtypes

Can use non-shieldedcontainment.

Around 20% cheaper

Negatives:

Needs correct earthing

Positive:

Industry Standard

Negatives:

EMC Issues

Larger Cables to combat EMCIssues

Larger Containment

ANEXT Issues (Alien)measurement required

Cannot mix and match cabletypes

Have to use shieldedcontainment

Much higher price approx.20%

V

Page 11: UC Copper / Fibre summary on USPs...MMS Multimedia Solutions | Introduction | MAR 2014 13 UC Copper Range Shielded solutions Focus on Cat. 6A / 7/ 7A Prepare for Cat.8 / 40G Patent

21MMS Multimedia Solutions | Introduction | MAR 2014

Cat.6A U/UTP

Please choose the containment type:

Enter Basket Width 200 mm

Enter Basket Depth 30 mm

Enter Distance between Supports mm

Please enter the cable diameter 8.9 mm

Please enter any future spare capacity for future %

(in percentage)

Maximum number of Cables 48(based on the information above)

This spreadsheet is for information only. Calculations based on relevant international standards V1.0 Nov'12

Page 12: UC Copper / Fibre summary on USPs...MMS Multimedia Solutions | Introduction | MAR 2014 13 UC Copper Range Shielded solutions Focus on Cat. 6A / 7/ 7A Prepare for Cat.8 / 40G Patent

22MMS Multimedia Solutions | Introduction | MAR 2014

Please choose the containment type:

Enter Basket Width 200 mm

Enter Basket Depth 30 mm

Enter Distance between Supports mm

Please enter the cable diameter 6.9 mm

Please enter any future spare capacity for future %

(in percentage)

Maximum number of Cables 80(based on the information above)

This spreadsheet is for information only. Calculations based on relevant international standards V1.0 Nov'12

Cat.6A U/FTP

Page 13: UC Copper / Fibre summary on USPs...MMS Multimedia Solutions | Introduction | MAR 2014 13 UC Copper Range Shielded solutions Focus on Cat. 6A / 7/ 7A Prepare for Cat.8 / 40G Patent

23MMS Multimedia Solutions | Introduction | MAR 2014

Please choose the containment type:

Enter Basket Width 200 mm

Enter Basket Depth 30 mm

Enter Distance between Supports mm

Please enter the cable diameter 7.1 mm

Please enter any future spare capacity for future %

(in percentage)

Maximum number of Cables 76(based on the information above)

This spreadsheet is for information only. Calculations based on relevant international standards V1.0 Nov'12

Cat.6A F/FTP

Page 14: UC Copper / Fibre summary on USPs...MMS Multimedia Solutions | Introduction | MAR 2014 13 UC Copper Range Shielded solutions Focus on Cat. 6A / 7/ 7A Prepare for Cat.8 / 40G Patent

24MMS Multimedia Solutions | Introduction | MAR 2014

Please choose the containment type:

Enter Basket Width 200 mm

Enter Basket Depth 30 mm

Enter Distance between Supports mm

Please enter the cable diameter 7.3 mm

Please enter any future spare capacity for future %

(in percentage)

Maximum number of Cables 72(based on the information above)

This spreadsheet is for information only. Calculations based on relevant international standards V1.0 Nov'12

Cat.6A S/FTP

Page 15: UC Copper / Fibre summary on USPs...MMS Multimedia Solutions | Introduction | MAR 2014 13 UC Copper Range Shielded solutions Focus on Cat. 6A / 7/ 7A Prepare for Cat.8 / 40G Patent

25MMS Multimedia Solutions | Introduction | MAR 2014

UC Cat.6A Cable Quantities

+40%%+37%%

+33%%

Page 16: UC Copper / Fibre summary on USPs...MMS Multimedia Solutions | Introduction | MAR 2014 13 UC Copper Range Shielded solutions Focus on Cat. 6A / 7/ 7A Prepare for Cat.8 / 40G Patent

26MMS Multimedia Solutions | Introduction | MAR 2014

UC500 S23 Cat6A U/FTP in Reelex

Highest robustness

ensured by Draka patented foildesign

Full Cat.6A performance

meets IEEE 802.3requirements for 10Gbase-Twith huge headroom

Improved handling

easy handling

Reelex boxes

Slimline Design (ø: 6.9mm)

Page 17: UC Copper / Fibre summary on USPs...MMS Multimedia Solutions | Introduction | MAR 2014 13 UC Copper Range Shielded solutions Focus on Cat. 6A / 7/ 7A Prepare for Cat.8 / 40G Patent

27MMS Multimedia Solutions | Introduction | MAR 2014

UC500 S23 Cat6A U/FTP on 500m Reels

reduce installation time

Cost of frame is approx. $5000.00

A cables, thanks to ourability to deliver them in Reelex boxes

Page 18: UC Copper / Fibre summary on USPs...MMS Multimedia Solutions | Introduction | MAR 2014 13 UC Copper Range Shielded solutions Focus on Cat. 6A / 7/ 7A Prepare for Cat.8 / 40G Patent

28MMS Multimedia Solutions | Introduction | MAR 2014

UCFUTURE Compact Cat.6A U/FTP

Design based on existing work area cable standards

Ideal for zone cabling in Data centres

Full 10GBase-T performance over a link distance of 60m

26 AWG conductor

Higher packing density

Improved air ventilation

Overall diameter smaller than CAT6 U/UTP

Page 19: UC Copper / Fibre summary on USPs...MMS Multimedia Solutions | Introduction | MAR 2014 13 UC Copper Range Shielded solutions Focus on Cat. 6A / 7/ 7A Prepare for Cat.8 / 40G Patent

29MMS Multimedia Solutions | Introduction | MAR 2014

Cat.6A & Cat.6 F/UTP versus U/FTPthe right ChoiceWith patented double S-foil design

Cat.6A F/UTP Cat.6A U/FTP

Cable diameter 7.2mm 6.9mm

Cable weight 55 kg 48.4kg

PS-Next -- ++RL - +Alien Next + +Mech. Performance Reelex -- +++Price + ++

UC500 S23 Cat.6A U/FTP the right choice

Page 20: UC Copper / Fibre summary on USPs...MMS Multimedia Solutions | Introduction | MAR 2014 13 UC Copper Range Shielded solutions Focus on Cat. 6A / 7/ 7A Prepare for Cat.8 / 40G Patent

30MMS Multimedia Solutions | Introduction | MAR 2014

F/UTP Design U/FTP Design

F/UTP Xtalk inherently has problems from one batch to the next; foilplacement and Spline extrusion are 2 areas of continued inconsistency.

Cat.6A Cable NEXT

UC500 S23 Cat.6A U/FTP the right choice

Page 21: UC Copper / Fibre summary on USPs...MMS Multimedia Solutions | Introduction | MAR 2014 13 UC Copper Range Shielded solutions Focus on Cat. 6A / 7/ 7A Prepare for Cat.8 / 40G Patent

31MMS Multimedia Solutions | Introduction | MAR 2014

F/UTP U/FTP

Much more margin with U/FTP

Cat.6A Cable ELFEXT

UC500 S23 Cat.6A U/FTP the right choice

Page 22: UC Copper / Fibre summary on USPs...MMS Multimedia Solutions | Introduction | MAR 2014 13 UC Copper Range Shielded solutions Focus on Cat. 6A / 7/ 7A Prepare for Cat.8 / 40G Patent

32MMS Multimedia Solutions | Introduction | MAR 2014

Cat.6A Robustness / Easy to install

U/FTP:

No Spline : improved flexibility

Sole design to resist to Reelex process

Sole design available in Reelex box

F/UTP:

Spline, difficult to control and make flexible

Single foil, similar problem both cause changes toReturn Loss and Xtalk:

double the problems; double the likelihood of lowmargin failure.

UC500 S23 Cat.6A U/FTP the right choice

Page 23: UC Copper / Fibre summary on USPs...MMS Multimedia Solutions | Introduction | MAR 2014 13 UC Copper Range Shielded solutions Focus on Cat. 6A / 7/ 7A Prepare for Cat.8 / 40G Patent

33MMS Multimedia Solutions | Introduction | MAR 2014

Greater transmission range for 10GBase-T: guaranteed 105mpermanent link PL2, up to 120m Channel

Designoptions UC LR22 S/FTP 10GUC LR22 F/FTP 10GUC LR22 U/FTP 10G

Product launchQ4