Top Banner
5/8/12 Transformer Oil Acidity Test Kit - Detailed info for Transformer Oil Acidity Test Kit,PH Test Kit,Transfo… 1/3 in103713286.trustpass.alibaba.com/product/…/Transformer_Oil_Acidity_Test_Kit.html Mr. Mandeep singh Add to my Contacts Home Products TrustPass Profile About Us Contacts home products Power and Distribution Transformer Test Equipments Transformer Oil Acidity Test Kit Transformer Oil Acidity Test Kit Report Suspicious Activity Add to My Favorites Product Details: Place of Origin Karnataka, India Brand Name JASMA Usage Power Phase Three Coil Structure Other Coil Number Other Operation type Motorised Stirrer magnetic Oil stirrer Payment & Shipping Terms: Price: Get Latest Price Minimum Order Quantity: 1 Set/Sets Packaging Details: As per customer requirements Delivery Time: Within 10 days from the time of reciept of Purchase Order Payment Terms: L/C,Demand Draft Supply Ability: 100 Set/Sets per Month Mr. Mandeep singh Offline Add to Inquiry Cart Transformer Oil Acidity Test Kit « Prev Product 1 2 3 4 5 6 7 ... Next Product » Detailed Product Description Oil Acidity Test kit to measure the Acidity of oil used in Transformers. Acidity Test New transformer oils contain practically no acids if properly refined. The acidity test measures the content of acids formed oxidation. The oxidation products polymerize to form sludge which then precipitates out. Acids react with metals on the surfaces inside the tank and form metallic soaps, another form of sludge. Sludging has been found to begin when the acid number reaches or exceeds 0.4, and 0.4 is considered to be the normal service limit. New oil has as acid number of less than 0.05. the acid number (formerly referred to as neutralization number) equals the milligrams of KOH (potassium hydroxide) required to neutralize the acid contained in 1 gram of oil. It is questionable whether an oil that is deteriorated to the point where its acid number exceeds 0.6 can be put back into lasting good condition by a single renovation. It is almost certain that two or more renovations, spaced 6 months to 1 year apart, would be necessary. It is recommended that an upper limit of 0.2 be used to determine when oil should be renovated, as a single renovation would most probably restore such an oil to very good condition. Oil showing an acid number of 0.15 or larger can be expected to show accelerated acid formation. Tests have been conducted which indicate the acidity is proportional to the amount of oxygen absorbed by the oil. It is estimated that 0.0015 m 3 /L (0.2 ft 3 /gal) of oxygen absorbed in oil will cause an acidity of about 0.4 mg of KOH, which is the approximate acidity number at which sludging is assumed to start. MONARCH CONTROLS Add Company to Favorites Product Showcase [10] Products [137] website Development [3] Business Consulting [10] Search Engine Optimization [38] Measuring Instruments [22] Transformers [40] Power and Distribution Transformer Test Equipments [15] Rubber Rollers [9] Company Profile Trade Show Certificates Contact Person Offline View Contact Details Transformer Oil BDV Testing Fully Automatic Oil BDV Tester with... Transformer Oil Acidity Test Kit Insulation Oil tester Dimmer Stat High Voltage Transformer Oil Cell Products search our products Language Option MONARCH CONTROLS [ ] A&V Checked Join Free | My Alibaba 3 rd year Search Product Search Match Supplier
3

Transformer oil Acidity

Aug 07, 2015

Download

Documents

Acidity test kit Information
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Transformer oil Acidity

5/8/12 Transformer Oil Acidity Test Kit - Detailed info for Transformer Oil Acidity Test Kit,PH Test Kit,Transfo…

1/3in103713286.trustpass.alibaba.com/product/…/Transformer_Oil_Acidity_Test_Kit.html

Mr. Mandeep singh

Add to my Contacts

Home

Products

TrustPass Profile

About Us

Contacts

home products Power and Distribution Transformer Test Equipments Transformer Oil Acidity Test Kit

Transformer Oil Acidity Test Kit

Report Suspicious Activity

Add to My Favorites

Product Details:

Place of Origin Karnataka, India

Brand Name JASMA

Usage Power

Phase Three

Coil Structure Other

Coil Number Other

Operation type Motorised

Stirrer magnetic Oil stirrer

Payment & Shipping Terms:

Price: Get Latest Price

Minimum Order Quantity: 1 Set/Sets

Packaging Details: As per customer requirements

Delivery Time: Within 10 days from the time of reciept ofPurchase Order

Payment Terms: L/C,Demand Draft

Supply Ability: 100 Set/Sets per Month

Mr. Mandeep singh

OfflineAdd to Inquiry Cart

Transformer Oil Acidity Test Kit

« Prev Product 1 2 3 4 5 6 7 ... Next Product »

Detailed Product Description

Oil Acidity Test kit to measure the Acidity of oil used in Transformers.

Acidity Test

New transformer oils contain practically no acids if properly refined. The acidity test measures the content of acids

formed oxidation. The oxidation products polymerize to form sludge which then precipitates out. Acids react with metals

on the surfaces inside the tank and form metallic soaps, another form of sludge. Sludging has been found to begin when

the acid number reaches or exceeds 0.4, and 0.4 is considered to be the normal service limit. New oil has as acid

number of less than 0.05. the acid number (formerly referred to as neutralization number) equals the milligrams of KOH

(potassium hydroxide) required to neutralize the acid contained in 1 gram of oil. It is questionable whether an oil that is

deteriorated to the point where its acid number exceeds 0.6 can be put back into lasting good condition by a single

renovation. It is almost certain that two or more renovations, spaced 6 months to 1 year apart, would be necessary. It is

recommended that an upper limit of 0.2 be used to determine when oil should be renovated, as a single renovation would

most probably restore such an oil to very good condition. Oil showing an acid number of 0.15 or larger can be expected

to show accelerated acid formation. Tests have been conducted which indicate the acidity is proportional to the amount

of oxygen absorbed by the oil. It is estimated that 0.0015 m3/L (0.2 ft3/gal) of oxygen absorbed in oil will cause an

acidity of about 0.4 mg of KOH, which is the approximate acidity number at which sludging is assumed to start.

MONARCH CONTROLS

Add Company to Favorites

Product Showcase [10]

Products [137]

website Development [3]

Business Consulting [10]

Search Engine Optimization [38]

Measuring Instruments [22]

Transformers [40]

Power and Distribution TransformerTest Equipments [15]

Rubber Rollers [9]

Company Profile

Trade Show

Certificates

Contact Person

Offline

View Contact Details

TransformerOil BDV Testing

Fully AutomaticOil BDV Tester

with...

TransformerOil Acidity Test

Kit

Insulation Oiltester

Dimmer Stat High VoltageTransformer

Oil CellProducts

search our products

Language Option

MONARCH CONTROLS

[ ]

A&V Checked

Join Free | My Alibaba

3rdyear

Search Product Search Match Supplier

Page 2: Transformer oil Acidity

5/8/12 Transformer Oil Acidity Test Kit - Detailed info for Transformer Oil Acidity Test Kit,PH Test Kit,Transfo…

2/3in103713286.trustpass.alibaba.com/product/…/Transformer_Oil_Acidity_Test_Kit.html

Transformer Oil Acidity Test Kit

Email to this supplier

« Prev Product 1 2 3 4 5 6 7 ... Next Product »

Transformer OilAcidity Test Kit

3 phase transformertesting

150KV, 500mA, HighVoltage Tester

0-60 KV Oil Test KitManual Operation

Ratio test oftransformer

Other Products from this Supplier

From: Enter email or Member ID.

To: Mr. Mandeep singh

Message:

Send

Enter your inquiry

details such as:

Self introduction

Required

specifications

Inquire about

price/MOQ

View sample

Page 3: Transformer oil Acidity

5/8/12 Transformer Oil Acidity Test Kit - Detailed info for Transformer Oil Acidity Test Kit,PH Test Kit,Transfo…

3/3in103713286.trustpass.alibaba.com/product/…/Transformer_Oil_Acidity_Test_Kit.html

Email this page Bookmark this page Print this page

Company Information - Site Map - Partnerships

Buy - Sell - My Alibaba - Community - Trade Shows - Safety & Security - Help - Contact Us

Browse by:Manufacturers - Wholesalers - China Gold Suppliers - All Products - Countries - Importers - Buying Leads - China - India - UK - Australia

Alibaba Group: Alibaba.com: Alibaba China - Alibaba International - AliExpress | Taobao Marketplace | Taobao Mall | eTao | Juhuasuan | Alibaba Cloud Computing |

China Yahoo! | Alipay

Product Listing Policy - Intellectual Property Policy and Infringement Claims - Privacy Policy - Terms of Use

Copyright Notice © 1999-2012 Alibaba.com Hong Kong Limited and licensors. All rights reserved.

Transformer oiltesting equipment

Transformer for OilTest Kit

Capacitor Bank CT PT Bank 30KV epoxy mouldedtransformer for BDV

Test Kit

0-100KV Transformerfor Oil Test Kit

0-100 KV Oil Test KitMotorised with stirrer

Transformer TestInstruments

AC/DC High VoltageTesting Transformer

600 Amps, oil cooled,Motorized

Autotransformer

Want to get more exact suppliers with detailed quotations? Post an RFQ now>>

Not sure about product quality? Find reliable inspectors to help ensure product quality!

Related Searches: ph test kit , acidity test kit , portable oil acidity test kit