Integrated HVAC Solutions for Light Commercial & Residential Buildings Optimize Comfort & Efficiency Flexible, Modular System Control Communicating Thermostats Remote Access & Adjustment Control Systems
12

tekmar Building Control Systems - Hydronic Heat Pump HVAC Solutions for Light ... ensure the zone is up to temperature at the ... tekmar Building Control Systems ...

Mar 19, 2018

Download

Documents

vuongcong
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: tekmar Building Control Systems - Hydronic Heat Pump HVAC Solutions for Light ... ensure the zone is up to temperature at the ... tekmar Building Control Systems ...

Integrated HVAC Solutions for Light Commercial & Residential Buildings

Optimize Comfort & Effi ciencyFlexible, Modular System Control Communicating ThermostatsRemote Access & Adjustment

••••

Control Systems

Page 2: tekmar Building Control Systems - Hydronic Heat Pump HVAC Solutions for Light ... ensure the zone is up to temperature at the ... tekmar Building Control Systems ...

Network-Wide schedules & scenes can be applied to any tekmarNet® capable device for convenience & energy savings.

One-Touch AdjustmenttekmarNet® User Switches & Thermostats provide simple

adjustment options.

tekmarNet® System Controls provide central intelligence for HVAC systems. The System Control collects

information from every tekmarNet® device, utilizing it to maximize system effi ciency,

increase equipment lifespan & provide the highest level of comfort possible.

tekmarNet® Communication provides an unmatched level of

comfort in every room.

Controls, The to Improve C

© 2009 P 315 - 07/09 2 of 12

Page 3: tekmar Building Control Systems - Hydronic Heat Pump HVAC Solutions for Light ... ensure the zone is up to temperature at the ... tekmar Building Control Systems ...

Web Access Web browser access can be provided remotely or on site with a tekmarNet® Gateway.

Two Stage Cooling, Ventilation & Heating enables a faster response to changing load

requirements. tekmarNet® Cooling Groups provide a Heat/Cool Interlock between thermostats.

HRV/ERV control with a choice

of fan settings

Hydronic Towel Rails & other accessories can be

push button operated or set to follow a schedule.

Outdoor Reset with Indoor Temperature Feedback

reduces water temperatures to ensure condensing boilers operate

at their maximum effi ciency.

rmostats & Accessories Work Together omfort, Convenience, & Fuel Effi ciency

3 of 12 © 2009 P 315 - 07/09

Page 4: tekmar Building Control Systems - Hydronic Heat Pump HVAC Solutions for Light ... ensure the zone is up to temperature at the ... tekmar Building Control Systems ...

ENERGY SAVING FEATURES

Outdoor ResetConserve energy by operating the system at the lowest practical temperature. As the outdoor temperature changes, the control adjusts supply water temperatures to compensate for exterior heat loss.

Warm Weather Shut DownShutting down the building space heating based on the outdoor air temperature provides energy savings as well as a reliable and convenient way to shut off the system.

Zone SynchronizationHeating cycles between zones are coordinated to reduce boiler cycling.

Pump Post PurgePrimary system pumps and in some cases boiler pumps are purged to make use of residual heat from the boiler.

Shared Setback SchedulesSetback times entered in one thermostat or timer can be followed by all connected tekmarNet® devices.

ScenesThe entire building can easily be set to an ‘Away’ status when occupants are away outside of scheduled times.

Automatic Boiler DifferentialEnsure longer running times and reduce boiler short cycling.

COMFORT FEATURES

Optimum Start / StopBy learning the response time of the heating system, tekmarNet® Thermostats ensure the zone is up to temperature at the scheduled time.

Indoor Temperature FeedbackInternal heat gains or losses are combined with outdoor reset calculations to better maintain the desired temperature without fl uctuation.

Domestic Hot Water PriorityEnsure adequate supply of domestic hot water during times of peak demand.

SYSTEM RELIABILITY & PROTECTION

Pump ExercisingDuring long periods without operation, pumps are exercised to reduce the chance of seizing or other failure.

Equal Run-Time RotationIncrease the system’s service life by ensuring the boilers receive an equal amount of use.

Remote AccessInstallations with a tekmarNet® Gateway provide secure access via the internet. Homeowners can remotely adjust temperatures, and installers can remotely monitor system operation and receive status alerts via email.

The tekmarNet® Building Control line is based upon modular components that combine to create a single, integrated

HVAC system. With capacity for up to 96 zones on several water temperatures and the ability to intelligently stage

and rotate multiple boilers, tekmarNet® Building Control Systems can match nearly any application.

A Modular Approach to Integrated Building HVAC Control

© 2009 P 315 - 07/09 4 of 12

Page 5: tekmar Building Control Systems - Hydronic Heat Pump HVAC Solutions for Light ... ensure the zone is up to temperature at the ... tekmar Building Control Systems ...

Up to 2 Modulating or On/Off Boilers(4 Mod or 9 On/Off using tekmar Stager)Up to 4 Water TemperaturesUp to 96 Zones with Pumps or ValvesDHW & Setpoint PriorityRemote Monitoring & Adjustment

••••

Mix Temperature 2 Tile Floors

Mix Temperature 1 Carpeted Floors

Mix Temperature 3 Hardwood Floors

Boiler Temperature Towel Rail with

Thermostatic Valve

Setpoint Demand Hot Tub

DHW Demand Domestic Hot Water

Complete System Control

5 of 12 © 2009 P 315 - 07/09

Page 6: tekmar Building Control Systems - Hydronic Heat Pump HVAC Solutions for Light ... ensure the zone is up to temperature at the ... tekmar Building Control Systems ...

tekmarNet®4 System Control

Zone and Power Managers are pre-installed in an ‘L’ Enclosure. Select a Zone or Power Manager based on the type of Zoning required.

Four Zone Pumps­336

Six Zone ValvesTwo Water Temperatures

­­

337

Power Supply without Zones­345 Power Supply without ZonesFor Systems with Remote Zoning

­­

346 Six Zone Valves­335

tN4 Zone & Power Managers

One On-Off or Modulating Boiler*DHW Generation with PrioritySetpoint Load Input

­­­

420

Select an Outdoor Reset Module to match boiler, mixing, DHW & setpoint requirements.

One On-Off BoilerOne Mixing Temperature(Floating / Variable Speed)

­­

421

Two Water TemperaturesOne On-Off or Modulating Boiler*DHW Generation with PrioritySetpoint Load Input

­­­­

422

Four Water TemperaturesTwo On-Off or Modulating Boilers*DHW Generation with PrioritySetpoint Load Input

­­­­

423

tN4 Outdoor Reset Modules

Zone or Power

Manager

Outdoor Reset

Module

L Enclosure

Thermally protected built-in transformersBuilt-in fuse protectionModular design for a wide range of applications

•••

Large Enclosure with Ample Room for Wiring

In most tekmarNet®4 (tN4) systems, mechanical room control is provided through a Zone Manager/Outdoor Reset Module combination. Add tekmarNet® Thermostats for a completely integrated control system.

*‘tekmar Stager’ feature provides for integration of a tekmar Boiler Control in systems with more than two boilers.

L Enclosure Included

Installs in L Enclosure

© 2009 P 315 - 07/09 6 of 12

Page 7: tekmar Building Control Systems - Hydronic Heat Pump HVAC Solutions for Light ... ensure the zone is up to temperature at the ... tekmar Building Control Systems ...

Expand the number of mixed temperatures in a tekmarNet®

system by connecting Mixing Expansion Modules to a Universal Reset Module 422 or 423.

tN4 Mixing Expansion ModulesVariable Speed or Floating ActionPowered System Pump OutputConnect to Zone or Power ManagerInstalls in L Enclosure

­­­­

440

441 Actuating Motor and Mix Module in OneFits tekmar 3 way & 4 way Brass ValvesAdaptor kit available to fi t Danfoss and Esbe 3MG, 4MG, G1 & G4 series valves

­­­

Variable Speed, 24 V (ac) Floating Action, Analog 0-10 V or 2-10 V (dc), or Analog 0-20 or 4-20 mA mixing options

­444

tN4 Wiring CenterstN4 Wiring Centers simplify wiring between tN4 Thermostats and zones. They can be installed at remote manifolds or in the mechanical room.

Up to Six Zone ValvesSynchronized End Switch

­­

315 Up to Four Zone PumpsSynchronized End Switch

­­

316

Zone Expansion Modules provide additional zoning when connected to a Zone or Power Manager.

Six Zone ValvesBuilt-in Transformer & FuseZone Group Pump

­­­

325

Three Zone PumpsZone Group Pump

­­

326

tN4 Zone Expansion Modules

tN4 Thermostats

Two Stage Heat, One Stage Cool & FanRemote SensingProgrammable Schedule

­

­­

545

546 Two Stage Heat, Two Stage Cool & Two FanHRV / ERV Ventilation ControlRemote SensingProgrammable Schedule

­­­­

544 One Stage Heat, One Stage Cool & FanRemote SensingProgrammable Schedule

­

­­

543 Two Stage HeatRemote SensingProgrammable Schedule

­­­

542 One Stage HeatRemote SensingProgrammable Schedule

­­­

537 One Stage Heat­

541 One Stage HeatRemote Sensing

­­

540 One Stage Heat, One Stage Cool & Fan

­

538 One Stage HeatFloor Sensing

­­

Two way communication with the System Control allows tN4 Thermostats to provide increased energy savings, a reduction in boiler cycling and steadier air temperatures. All tN4 Thermostats can follow setback schedules and respond to scenes.

440 444 441

Installs in L Enclosure

7 of 12 © 2009 P 315 - 07/09

Page 8: tekmar Building Control Systems - Hydronic Heat Pump HVAC Solutions for Light ... ensure the zone is up to temperature at the ... tekmar Building Control Systems ...

tN4 TimerTwo or Four Events5-1-1, 5-2, 7 Day or 24 hr Schedule

­­

033 With up to four unique setback schedules for use by tekmarNet® Controls & Thermostats, the Timer 033 makes saving energy easy.

tN4 User SwitchesA single push of a button on a tekmarNet® User Switch can change the heating & cooling settings for the entire tekmarNet® system. Other uses include remote system access through a telephone switch, and setpoint device operation.

Pre-ProgrammedOccupied/Unoccupied/Away

­­

479

Fully ProgrammableThree Inputs for External Scene Activation

­­

480

Fully ProgrammableThree OutputsActivation of Scenes, Setpoints and EMS/BAS System

­­­

481

tN4 Setpoint ControlsThe tN4 Setpoint Controls allow you to easily integrate setpoint loads into a tN4 system. Modes of operation for DHW, Hot Tub, Pool and Floor Heating make setup easy. Prioritize, schedule or enable each setpoint load using tekmarNet®.

One Stage HeatSingle Relay

­­

161

One Stage Heat or CoolProgrammable ScheduleAuxiliary Relay

­­­

162

With a tN4 Gateway, HVAC system data is displayed on web pages that can be viewed on-site, or remotely via the internet.

View & change current scene statusView trending dataAdjust set temperaturesEnable or turn off setpoint devicesSend event notification emails

•••••

tN4 Gateway

483 USB Connection to Mac OSX Web ServerTwo Wire, 18 AWG Connection to each tN4 BusNo monthly service fees

­

­

­

Refer to the charts on page 10 and 11 for a feature comparison.

© 2009 P 315 - 07/09 8 of 12

Page 9: tekmar Building Control Systems - Hydronic Heat Pump HVAC Solutions for Light ... ensure the zone is up to temperature at the ... tekmar Building Control Systems ...

tekmar’s two wire products make it easy to retrofi t with tekmarNet®. Two wire devices are identifi ed as tekmarNet®2 (tN2).

With tN2 Thermostats, you can use existing 2 conductor, 18 AWG wire to replace old thermostats with models that offer the energy savings, comfort and convenience your customers want. Power and communication for these thermostats is provided by a tN2 Zone Manager, Zone Expansion Module or Wiring Center.

tN2 Thermostats

527 One Stage Heat­

530 One Stage Heat, One Stage Cool & Fan

­

528 One Stage HeatFloor Sensing

­­

Simple digital interfaceDual temperature displayShared setback SchedulesNon-polarity sensitive wiring

tN2 Zone Managers provide power and communication for an Outdoor Reset Module, Zone or Mixing Expansion Module as well as connected tN2 Thermostats and Zone Pumps or Valves. They are pre-installed in an ‘L’ Enclosure.

tN2 Zone Managers

Four Zone Valves OR PumpsPowered Zone Group PumpCool & Fan Relay Terminals

­­­

334

Zone Expansion Modules provide additional zoning when connected to a Zone or Power Manager.

Four Zone Valves OR PumpsPowered Zone Group PumpCool & Fan Relay Terminals

­­­

324

tN2 Zone Expansion Modules

tN2 Wiring CentersWiring Centers simplify wiring between tN2 Thermostats and zones. They can be installed at remote manifolds or in the mechanical room.

Up to Four Zone ValvesIsolated End Switch

­­

313 Up to Four Zone PumpsIsolated End Switch

­­

314

Installs in L Enclosure

9 of 12 © 2009 P 315 - 07/09

Page 10: tekmar Building Control Systems - Hydronic Heat Pump HVAC Solutions for Light ... ensure the zone is up to temperature at the ... tekmar Building Control Systems ...

© 2009 P 315 - 07/09 10 of 16

Outdoor Reset Modules Mixing Expansion ModulesFunctions 420 421 422 423 440 441 444Number of Boilers 1 1 1 2Modulating Boiler • • •On-Off Boiler • • • •Number of Water Temperatures 1 1 1 + 1* 4* 1 1 1Boiler OperationBoiler Outdoor Reset • • •Boiler Load Reset • • •Boiler Auto Differential • • • •External Multiple Boiler Control • • •DHW OperationDHW Priority • • •DHW through Pump • • •DHW through Valve • •Setpoint OperationSetpoint Priority • • •Mixing OperationMixing Outdoor Reset • • • • • •Variable Speed Output • • • •Floating Action Output • • • • •Analog 0-20 mA or 4-20 mA •Analog 0-10 V (dc) or 2-10 V (dc) •Boiler Return Protection • • • • • •System Maximum Supply • • • • • •General OperationIndoor Temperature Feedback • • • •Warm Weather Shut Down • • • •Exercising • • • • • • •Access Levels • • • •Auto Test • • • •Maxheat • • • • • • •Flushing • • • • • •

* Each mixing water temperature requires a Mixing Expansion Module 440, 441 or 444

Zone & Power Managers Zone Expansion Wiring CentersFunctions 334 335 336 337 345 346 324 325 326 313 314 315 316Power for Reset Module • • • • • •tekmarNet® Type tN2 tN4 tN4 tN4 tN4 tN4 tN2 tN4 tN4 tN2 tN2 tN4 tN4Number of Zones 4 6 4 3 + 3 1 3 4 6 3 4 4 6 4Water Temperatures 1 1 1 2 1 1 1 1 1 1 1Zone Valves •

OR•• • •

OR•• • •

Zone Pumps • • • • • •Zone Group Pump 1 1 1 2 1 1 1Zone Group Pump Delay • • • • •On-Board Transformer 40 VA 40 VA 40 VA 40 VA 40 VA 56 VAOn-Board Fuse • • • • • • •Cooling Connection • •

Control Feature Comparison

Functions 161 162Operation Heat Heat or CoolRecirculation Pump Relay •Programmable Schedule •Priority Setting • •

Setpoint Feature Comparison

© 2009 P 315 - 07/09 10 of 12

Page 11: tekmar Building Control Systems - Hydronic Heat Pump HVAC Solutions for Light ... ensure the zone is up to temperature at the ... tekmar Building Control Systems ...

11 of 16 © 2009 P 315 - 07/09

Thermostat Feature ComparisonFunctions 527 528 530 537 538 540 541 542 543 544 545 5464 Wire / tekmarNet®4 • • • • • • • • •2 Wire / tekmarNet®2 • • •Heat Stages 1 1 1 1 1 1 1 1 2 1 2 2Cool Stages 1 1 1 1 2Fan Stages 1 1 1 1 2Stand Alone Operation • • • • • • • • •Auxiliary Sensor Inputs 1 1 1 2 2 2 2 3Aux Outdoor Sensor • • • • • • • •Aux Floor Sensor • • • • • • • •Aux Remote Room Sensor • • • • • •Aux Remote Display Sensor • • • • • •Aux Coil Sensor • •Aux Duct Sensor • •HeatingFloor Warming • • • • • • • •Zone Synchronization • • • • • • • • • • • •Zone Post Purge • • • • • • • • • • • •Auto Heating Cycle • • • • • • • • • • • •Adjustable Heat Cycle Length • • • • • •Adjustable Heat Terminal • • • • • •Radiant Base Load • •Warm Weather Shut Down • • • • •Cooling & VentilationAuto Heat-Cool Switchover • • • • •Cool Group Master • • • •Cool Group Member • • • • • • • • •Cool Min On and Off Times • • • • •Auto/Adjustable Cooling Cycle • • • • •Cooling Interlock • • • • •Ventilation Fan / ERV/ HRV • • • • •Fan Coil Min/Max • •Filter • • •Heat/Cool Priority • • •Cold Weather Shut Down • • •SetbackOptimum Start • • • • • • • • • • • •Schedule Master • • • • •Schedule Member • • • • • • • • • • • •Scenes • • • • • • • • • • • •Away Override Time • • • • •Adjustable Away Temperature • • • • • • • • • •Temporary Hold • • • • • •Daylight Savings Time • •Separate Heat & Cool Schedules • •MiscellaneousMonitor Outdoor Hi’s & Lo’s • • • • •Monitor Room Hi’s & Lo’s • • •Monitor Room Hot & Cold Alarms • • •Monitor Relay On Times • • •Test Menu • • •Exercise • • • • • • • • • • • •Copy Settings Feature • • • • • •

11 of 12 © 2009 P 315 - 07/09

Page 12: tekmar Building Control Systems - Hydronic Heat Pump HVAC Solutions for Light ... ensure the zone is up to temperature at the ... tekmar Building Control Systems ...

tekmar Control Systems Ltd., Canadatekmar Control Systems, Inc., U.S.A.Head Office: 5100 Silver Star RoadVernon, B.C. Canada V1B 3K4(250) 545-7749 Fax. (250) 545-0650Web Site: www.tekmarcontrols.com

Product design, software and literature are Copyright © 2009 by:tekmar Control Systems Ltd. and tekmar Control Systems, Inc. 12 of 12 All specifications are subject to change without notice.

Printed in Canada. P 315 - 07/09.

Additional applications can be downloaded from the Literature section of the tekmar website.

AdditionalZones

AdditionalZones

AdditionalZones

441

AdditionalZones

Two Modulating or On/Off Boilers for Space Heating & DHW. Three Mixed Temperatures plus One Boiler Temperature. Pump & Valve Zones.

Single On/Off Boiler for Space Heating & DHW. Up to Ninety-Six Zones.

Single On/Off Boiler for Space Heating, DHW & Setpoint. Two Mixed Water Temperatures. Pump & Valve Zones.

420 336336

422 336

335440162

423 336 441 335

336 444 325440