Obtain And Record Single-Shell Tank Temperature Data Type CONTINUOUS Document No. TO-040-650 Rev/Mod H-7 Release Date 01/03/2019 Page 1 of 61 Tank Farm Plant Operating Procedure SURVEILLANCE USQ # TF-19-0013-D, Rev 0 CHANGE HISTORY ( LAST 5 REV-MODS ) Rev-Mod Release Date Justification: Summary of Changes H-7 01/03/2019 WRPS-PER-2018-1604 Removed references to PCSACS. H-6 06/25/2018 Changes identified during Periodic Review Process Update records section to comply with standard. Update all Data Sheets to include print/sign/date per procedure standard. H-5 02/22/2018 Operations request Page 44: Shade out BX-109, Riser 3, Position 5. No longer able to obtain temperature reading. Page 61: Shade out BY-103, Riser 5, Position 8. No longer able to obtain temperature reading. Deleted temperature readings for thermocouple trees that have been removed in AX farm. Added Section 3.2 Equipment Safety and sub steps with white label program statement. H-4 06/05/2017 Operations request Page 38: - SHADE OUT - B-104, Riser 5 and B-107 Riser 3, remaining Selector Switch Positions. Unable to obtain readings. Page 39: - SHADE OUT - B-110, Riser 8 and B-201 Riser 1, remaining Selector Switch Positions. Unable to obtain readings. Page 47: - SHADE OUT - C-105, Riser 1, remaining Selector Switch Positions. Unable to obtain readings. Page 48: - SHADE OUT - C-110, Riser 8 Selector Switch Position 9. Unable to obtain readings. H-3 12/01/2016 Operations request Page 38: SHADE OUT – B-102: Riser 4, Selector Switch Position 7 Page 38: SHADE OUT – B-109: Riser 1, Selector Switch Position 5 Table of Contents Page 1.0 PURPOSE AND SCOPE ................................................................................................................ 4 1.1 Purpose................................................................................................................................ 4 1.2 Scope ................................................................................................................................... 4 2.0 INFORMATION............................................................................................................................. 5 2.1 Terms and Definitions......................................................................................................... 5 2.2 General Information ............................................................................................................ 5 3.0 PRECAUTIONS AND LIMITATIONS......................................................................................... 6 3.1 Personnel Safety.................................................................................................................. 6 3.2 Equipment Safety ................................................................................................................ 6
61
Embed
Tank Farm Plant Operating Procedure SURVEILLANCE USQ # … Library/011819/Operating...Tank Farm Plant Operating Procedure SURVEILLANCE ... Table 2: East Area Manual Tank With No Thermocouple
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
1 of 61
Tank Farm Plant Operating Procedure SURVEILLANCE
USQ # TF-19-0013-D, Rev 0
CHANGE HISTORY ( LAST 5 REV-MODS )
Rev-Mod Release Date Justification: Summary of Changes
H-7 01/03/2019 WRPS-PER-2018-1604 Removed references to PCSACS.
H-6 06/25/2018 Changes identified during
Periodic Review Process
Update records section to comply with standard. Update all Data
Sheets to include print/sign/date per procedure standard.
H-5 02/22/2018 Operations request
Page 44: Shade out BX-109, Riser 3, Position 5. No longer able
to obtain temperature reading.
Page 61: Shade out BY-103, Riser 5, Position 8. No longer able
to obtain temperature reading.
Deleted temperature readings for thermocouple trees that have
been removed in AX farm.
Added Section 3.2 Equipment Safety and sub steps with white
label program statement.
H-4 06/05/2017 Operations request
Page 38: - SHADE OUT - B-104, Riser 5 and B-107 Riser
3, remaining Selector Switch Positions. Unable to obtain
readings.
Page 39: - SHADE OUT - B-110, Riser 8 and B-201 Riser
1, remaining Selector Switch Positions. Unable to obtain
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
29 of 61
Table 8: Selector Switch / Thermocouple Number (Cont.)
S-111
Riser 4
Switch Position 1 2 3 4 5 6 7 8 9 10 11 12
Thermocouple # 1 2 3 4 5 6 7 8 9 10 11 13
S-112
Riser 4
Switch Position 1 2 3 4 5 6 7 8 9 10 11 12
Thermocouple # 1 2 3 4 5 6 7 8 9 10 11 13
SX-101
Riser 15
Switch Position 1 2 3 4 5 6
Thermocouple # 1 2 3 4 5 6
SX-102
Riser 16
Switch Position 1 2 4 5 6
Thermocouple # 1 2 4 5 6
SX-103
Riser 2
Switch Position 1 2 3 4 5 6
Thermocouple # 1 2 3 4 5 6
SX-104
Riser 2
Switch Position 1 2 3 4 6
Thermocouple # 1 2 3 4 6
SX-105
Riser 2
Switch Position 2 3 4 6
Thermocouple # 2 3 4 6
SX-106
Riser 16
Switch Position 1 2 3 4
Thermocouple # 1 2 3 4
SX-107
Riser 10
Switch Position 1 2 3 4 8
Thermocouple # 1 2 3 4 8
SX-107
Riser 14
Switch Position 1 2 3
Thermocouple # 1 2 3
SX-108
Riser 10
Switch Position 1 2 3 4
Thermocouple # 1 2 3 4
SX-108
Riser 19
Switch Position 1 2 3 4
Thermocouple # 1 2 3 4
SX-109
Riser 10
Switch Position 1 2 3 4 5 6 8
Thermocouple # 1 2 3 4 5 6 8
SX-109
Riser 19
Switch Position 1 2 3 4 5 6 8
Thermocouple # 1 2 3 4 5 6 8
SX-110
Riser 12
Switch Position 4 8
Thermocouple # 4 8
SX-110
Riser 20
Switch Position 1 2 3 8
Thermocouple # 1 2 3 8
SX-111
Riser 10
Switch Position 1 2 3 4 5 8
Thermocouple # 1 2 3 4 5 8
SX-111
Riser 19
Switch Position 1 2 3 4 8
Thermocouple # 1 2 3 4 8
SX-112
Riser 10
Switch Position 1 2 3 4 8
Thermocouple # 1 2 3 4 8
SX-112
Riser 19
Switch Position 1 2 3 8
Thermocouple # 1 2 3 8
SX-113
Riser 3
Switch Position 1 16
Thermocouple # 1 16
(Table 8 - Continued on Next Page)
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
30 of 61
Table 8: Selector Switch / Thermocouple Number (Cont.)
SX-114
Riser 10
Switch Position 1 2 3 4 5 6 8
Thermocouple # 1 2 3 4 5 6 8
SX-114
Riser 19
Switch Position 1 2 3 4 5 6
Thermocouple # 1 2 3 4 5 6
T-101
Riser 8
Switch Position 1 2 3
Thermocouple # 1 2 3
T-103
Riser 8
Switch Position 5 6 7 8
Thermocouple # 1 2 7 11
T-104
Riser 4
Switch Position 1 3 4 5 6 7 8 9
Thermocouple # 1 3 4 5 6 7 8 11
T-106
Riser 8
Switch Position 2 3 4
Thermocouple # 2 7 11
T-107
Riser 4
Switch Position 1 2 3 4 5 6
Thermocouple # 1 2 3 4 8 11
T-108
Riser 4
Switch Position 7 8 9 10
Thermocouple # 1 2 7 11
T-109
Riser 8
Switch Position 6 7 9
Thermocouple # 1 2 7
T-110
Riser 8
Switch Position 1 2 3 4 5 6 7 8 9
Thermocouple # 1 2 3 4 5 6 7 9 11
T-111
Riser 5
Switch Position 1 2 3 6 7 9
Thermocouple # 1 2 3 6 7 11
T-112
Riser 8
Switch Position 1 2 3 4 5
Thermocouple # 1 2 3 7 11
T-201
Riser 5
Switch Position 1 2 3 4 5 6 7 8 9
Thermocouple # 1 2 3 4 5 6 7 8 11
T-202
Riser 5
Switch Position 10 11 12 13 14 15 16 17
Thermocouple # 1 2 3 4 5 6 9 11
T-203
Riser 8
Switch Position 1 2 3 4 5 6 7 8 9 10
Thermocouple # 1 2 3 4 5 6 7 8 9 11
T-204
Riser 8
Switch Position 11 12 13 14 16 17 18 19 20
Thermocouple # 1 2 3 4 6 7 8 9 11
TX-102
Riser 4
Switch Position 1 2 3 4 5 6
Thermocouple # 1 2 3 4 5 10
TX-103
Riser 4
Switch Position 7 8 9 10 11
Thermocouple # 1 2 3 4 10
TX-104
Riser 4
Switch Position 13 14 15
Thermocouple # 2 3 10
TX-105
Riser 4
Switch Position 1 5
Thermocouple # 1 5
TX-106
Riser 4
Switch Position 1 2 3 4 5 6 7 8 9
Thermocouple # 1 2 3 4 5 6 7 8 11
(Table 8 - Continued on Next Page)
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
31 of 61
Table 8: Selector Switch / Thermocouple Number (Cont.)
TX-107
Riser 4
Switch Position 10 11 12
Thermocouple # 1 2 10
TX-108
Riser 4
Switch Position 1 2 3 4 5
Thermocouple # 1 2 3 4 10
TX-109
Riser 8
Switch Position 7 8 9 10 11 12 13 14
Thermocouple # 1 2 3 4 5 6 7 8
TX-111
Riser 8
Switch Position 13 14 15 16 17 18 19 20
Thermocouple # 1 2 3 4 5 6 7 10
TX-112
Riser 8
Switch Position 1 2 3 4 5 6 7 8 9 10 11 12
Thermocouple # 1 2 3 4 5 6 7 8 9 10 11 13
TX-113
Riser 8
Switch Position 1 2 3 4 5 6 7 8 9 10 11 12
Thermocouple # 1 2 3 4 5 6 7 8 9 10 11 13
TX-115
Riser 3
Switch Position 1 2 3 4 5 6 7 8 9 10 11 12
Thermocouple # 1 2 3 4 5 6 7 8 9 10 11 13
TX-118
Riser 1
Switch Position 1 2 3 4 5 6
Thermocouple # 1 2 3 4 5 6
TX-118
Riser 3
Switch Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Thermocouple # 1 2 3 4 5 6 7 8 9 10 11 12 13 14
TY-101
Riser 4
Switch Position 1 2 3 4 5 6 7 8 9 11 12 13 14
Thermocouple # 1 2 3 4 5 6 7 8 9 11 12 13 14
TY-101
Riser 3
Switch Position 1 2 3 4 5 6 7 8
Thermocouple # 1 2 3 4 5 6 7 8
TY-102
Riser 4
Switch Position 3 4
Thermocouple # 7 11
TY-103
Riser 4
Switch Position 2 3 5 6 7 8 9 10 11 12 13 14
Thermocouple # 2 3 5 6 7 8 9 10 11 12 13 14
TY-104
Riser 4
Switch Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Thermocouple # 1 2 3 4 5 6 7 8 9 10 11 12 13 14
TY-105
Riser 3
Switch Position 1 2 3 4 5 6 7
Thermocouple # 1 2 3 4 5 8 11
TY-106
Riser 2
Switch Position 1 2 3 4
Thermocouple # 1 2 7 11
U-101
Riser 2
Switch Position 1 2 3
Thermocouple # 1 2 10
U-102
Riser 1
Switch Position 1 2 3 4 5 6 7 8
Thermocouple # 1 2 3 4 5 6 7 10
U-103
Riser 1
Switch Position 10 11 12 13 14 15 16 17
Thermocouple # 2 3 4 5 6 7 8 10
(Table 8 - Continued on Next Page)
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
32 of 61
Table 8: Selector Switch / Thermocouple Number (Cont.)
U-105
Riser 1
Switch Position 1 2 3 4 5 6 7 8 9
Thermocouple # 1 2 3 4 5 6 7 8 10
U-106
Riser 1
Switch Position 10 11 12 13 14 15
Thermocouple # 1 2 3 4 5 10
U-107
Riser 1
Switch Position 4 5 6 7 8 9 10 11
Thermocouple # 1 2 3 4 5 6 7 10
U-108
Riser 1
Switch Position 1 2 3 4 5 6 7 8 9
Thermocouple # 1 2 3 4 5 6 7 8 10
U-109
Riser 1
Switch Position 10 11 12 13 14 15 16 17 18
Thermocouple # 1 2 3 4 5 6 7 8 10
U-110
Riser 1
Switch Position 12 13 14 15 16
Thermocouple # 1 2 3 4 10
U-111
Riser 5
Switch Position 1 2 3 4 5 6 7
Thermocouple # 1 2 3 4 5 6 10
U-112
Riser 5
Switch Position 9 10
Thermocouple # 2 10
U-201
Riser 4
Switch Position 1 2 3
Thermocouple # 1 2 8
U-202
Riser 4
Switch Position 4 5 6
Thermocouple # 1 2 8
U-203
Riser 4
Switch Position 7 8 9
Thermocouple # 1 2 8
U-204
Riser 4
Switch Position 10 11 12
Thermocouple # 1 2 8
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
33 of 61
Data Sheet 1: 241-A Farm Quarterly Manual Temperatures
Sheet ___ of ___
Tank Instrument
Type
OSD
Limit F
Selector Switch Position
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
*102
Riser 7 J 280
*103
Riser 15 J 280
*106
Riser 14 J 280
Comments:
Data Collection Instruments
Instrument Model #: Signature Print Name
(First and Last) Date
Instrument ID #:
Operator:
Calibration Due Date: Shift Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule.
- Temperature Limits are established per OSD-T-151-00013.
- Shaded areas indicate that no data entry is required. * - Readings obtained in 271-A Control Room.
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
34 of 61
Data Sheet 2: Tank 241- A-104 and 241-A-105 Quarterly Sludge Temperatures
Sheet ___ of ___
Tank Instrument
Type
OSD
Limit F
104
Riser 17 K 280
105
Riser 9 E 280
105
Riser 15 E 280
105
Riser 16 E 280
105
Riser 17 E 280
105
Riser 19 E 280
105
Riser 22 E 280
Comments:
Data Collection Instruments
Instrument Model #:
Signature Print Name
(First and Last) Date
Instrument ID #: Operator:
Calibration Due Date:
Shift Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule. - Temperature Limits are established per OSD-T-151-00013.
- Shaded areas indicate that no data entry is required.
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
35 of 61
Data Sheet 3: 241-A/AX Quarterly Temperatures
Sheet ___ of ___
A/AX Farm Quarterly Temperatures
Date Completed:
241-A-105 Lateral Temperatures on Selector Switch A105-WST-SS-101 (Box TB-A)
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
36 of 61
Data Sheet 4: 241-B Farm Quarterly Manual Temperatures
Sheet ___ of ___
Tank Instrument
Type
OSD
Limit F
Selector Switch Position
1 2 3 4 5 6 7 8 9 10 11 12
101
Riser 9 J 280
102
Riser 4 J 280
104
Riser 5 J 280
105
Riser 15 J 280
106
Riser 4 J 280
107
Riser 3 J 280
108
Riser 5 J 280
109
Riser 1 J 280
Comments:
Data Collection Instruments
Instrument Model #:
Signature Print Name
(First and Last) Date
Instrument ID #:
Operator:
Calibration Due Date:
Shift Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule.
- Temperature Limits are established per OSD-T-151-00013.
- Shaded areas indicate that no data entry is required. - For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken.
(Data Sheet 4 - Continued on Next Page)
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
37 of 61
Data Sheet 4: 241-B Farm Quarterly Manual Temperatures (Cont.)
Sheet ___ of ___
Tank Instrument
Type
OSD
Limit F
Selector Switch Position
1 2 3 4 5 6 7 8 9 10 11 12
110
Riser 8 J 280
111
Riser 8 J 280
112
Riser 1 J 280
201
Riser 1 J 280
202
Riser 1 J 280
203
Riser 1 J 280
204
Riser 1 J 280
Comments:
Data Collection Instruments
Instrument Model #:
Signature Print Name
(First and Last) Date
Instrument ID #: Operator:
Calibration Due Date:
Shift Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule.
- Temperature Limits are established per OSD-T-151-00013.
- Shaded areas indicate that no data entry is required. - For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken.
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
38 of 61
Data Sheet 5: 241 A Farm Quarterly TMACS Temperatures
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule.
- Temperature Limits are established per OSD-T-151-00013. - Shaded areas indicate that no data entry is required.
* Upper switch position for Thermocouples 17 and 18.
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
39 of 61
Data Sheet 6: 241-AX Farm Quarterly TMACS Temperatures
Sheet ___ of ___
Tank Instrument
Type
OSD
Limit F
Selector Switch Position
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
(1) 101
Riser 9B J 280
(2) 103
Riser 9B J 280
Comments:
Data Collection Instruments
Instrument Model #:
Signature Print Name
(First and Last) Date
Instrument ID #:
Operator:
Calibration Due Date: Shift Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule. - Temperature Limits are established per OSD-T-151-00013.
- Shaded areas indicate that no data entry is required.
- For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken. (1) Field Reading obtained on Terminal Box TMACS-TBX-802.
(2) Field reading obtained on Selector Switch AX103-WST-SS-103.
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
40 of 61
Data Sheet 7: 241-B Farm Quarterly TMACS Temperatures
Sheet ___ of ___
Tank Instrument
Type
OSD
Limit F
Selector Switch Position
1 2 3 4 5 6 7 8 9 10 11 12
103
Riser 4 J 280
Comments:
Data Collection Instruments
Instrument Model #: Signature Print Name
(First and Last) Date
Instrument ID #: Operator:
Calibration Due Date: Shift Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule. - Temperature Limits are established per OSD-T-151-00013.
- Shaded areas indicate that no data entry is required. - For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken.
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
41 of 61
Data Sheet 8: 241-BX Farm Quarterly Manual Temperatures
Sheet ___ of ___
Tank Instrument
Type
OSD
Limit F
Selector Switch Position
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
101
Riser 2 J 280
102
Riser 8 J 280
103
Riser 1 J 280
105
Riser 7 J 280
106
Riser 1 K 280
106
Riser 7 J 280
107
Riser 4 J 280
108
Riser 5 J 280
Comments:
Data Collection Instruments
Instrument Model #:
Signature Print Name
(First and Last) Date
Instrument ID #:
Operator:
Calibration Due Date:
Shift Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule.
- Temperature Limits are established per OSD-T-151-00013. - Shaded areas indicate that no data entry is required.
- For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken.
(Data Sheet 8 - Continued on Next Page)
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
42 of 61
Data Sheet 8: 241-BX Farm Quarterly Manual Temperatures (Cont.)
Sheet ___ of ___
Tank Instrument
Type
OSD
Limit F
Selector Switch Position
1 2 3 4 5 6 7 8 9 10 11 12 13
109
Riser 3 J 280
109
Riser 5 J 280
110
Riser 1 J 280
111
Riser 1 J 280
112
Riser 1 J 280
Comments:
Data Collection Instruments
Instrument Model #:
Signature Print Name
(First and Last) Date
Instrument ID #:
Operator:
Calibration Due Date:
Shift Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule.
- Temperature Limits are established per OSD-T-151-00013.
- Shaded areas indicate that no data entry is required.
- For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken.
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
43 of 61
Data Sheet 9: 241-BY Farm Quarterly Manual Temperatures
Sheet ___ of ___
Tank Instrument
Type
OSD
Limit F
Selector Switch Position
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
101
Riser 1 J 280
103
Riser 1 J 280
104
Riser 1 J 280
104
Riser 10B K 280
* 105
Riser 1 J 280
105
Riser 10C J 280
106
Riser 1 J 280
107
Riser 1 J 280
Comments:
Data Collection Instruments
Instrument Model #:
Signature Print Name
(First and Last) Date
Instrument ID #:
Operator:
Calibration Due
Date:
Shift Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule.
- Temperature Limits are established per OSD-T-151-00013.
- Shaded areas indicate that no data entry is required. - For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken.
* Selector Switch 7 starts with Thermocouple 1 on Riser 1 as found in the TMACS database.
(Data Sheet 9 - Continued on Next Page)
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
44 of 61
Data Sheet 9: 241-BY Farm Quarterly Manual Temperatures (Cont.)
Sheet ___ of ___
Tank Instrument
Type
OSD
Limit F
Selector Switch Position
1 2 3 4 5 6 7 8 9 10 11 12 13 14
108
Riser 8 J 280
110
Riser 1 E 280
110
Riser 10A K 280
111
Riser 14 K 280
112
Riser 2 K 280
Comments:
Data Collection Instruments
Instrument Model #:
Signature Print Name
(First and Last) Date
Instrument ID #:
Operator:
Calibration Due Date:
Shift Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule.
- Temperature Limits are established per OSD-T-151-00013. - Shaded areas indicate that no data entry is required.
- For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken.
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
45 of 61
Data Sheet 10: 241-C Farm Quarterly Manual Temperatures
Sheet ___ of ___
Tank Instrument
Type
OSD
Limit F
Selector Switch Position
1 2 3 4 5 6 7 8 9 10 11
105
Riser 1 E 280
106
Riser 8 E 280
107
Riser 5 E 280
108
Riser 1 K 280
Comments:
Data Collection Instruments
Instrument Model #:
Signature Print Name
(First and Last) Date
Instrument ID #:
Operator:
Calibration Due Date:
Shift Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule.
- Temperature Limits are established per OSD-T-151-00013.
- Shaded areas indicate that no data entry is required. - For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken.
(Data Sheet 10 - Continued on Next Page)
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
46 of 61
Data Sheet 10: 241-C Farm Quarterly Manual Temperatures (Cont.)
Sheet ___ of ___
Tank Instrument
Type
OSD
Limit F
Selector Switch Position
1 2 3 4 5 6 7 8 9 10 11 12 13 14
108
Riser 5 J 280
109
Riser 8 J 280
110
Riser 8 J 280
111
Riser 5 J 280
112
Riser 1 J 280
112
Riser 8 K 280
Comments:
Data Collection Instruments
Instrument Model #: Signature Print Name
(First and Last) Date
Instrument ID #: Operator:
Calibration Due Date: Shift Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule.
- Temperature Limits are established per OSD-T-151-00013.
- Shaded areas indicate that no data entry is required. - For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken.
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
47 of 61
Data Sheet 11: 241-S Farm Quarterly TMACS Temperatures
Sheet ___ of ___
Tank Instrumen
t Type
OSD
Limit F
Selector Switch Position
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 * 12
101
Riser 14 J 280
103
Riser 4 J 280
104
Riser 4 J 280
105
Riser 4 J 280
106
Riser 2 J 280
107
Riser 4 J 280
Comments:
M&TE
Instrument Model #:
Signature Print Name
(First and Last) Date
Instrument ID #:
Operator:
Calibration Due Date:
Shift Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule. - Temperature Limits are established per OSD-T-151-00013.
-Shaded areas indicate that no data entry is required.
-For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken. * This Selector Switch 12 reading is from the upper Selector Switch for S-105.
(Data Sheet 11 - Continued on Next Page)
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
48 of 61
Data Sheet 11: 241-S Farm Quarterly TMACS Temperatures (Cont.)
Sheet ___ of ___
Tank Instrument
Type
OSD
Limit F
Selector Switch Position
1 2 3 4 5 6 7 8 9 10 11 12
108
Riser 4 J 280
109
Riser 4 J 280
110
Riser 4 J 280
111
Riser 4 J 280
112
Riser 4 J 280
Comments:
M&TE
Instrument Model #:
Signature Print Name
(First and Last) Date
Instrument ID #:
Operator:
Calibration Due Date:
Shift Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule.
- Temperature Limits are established per OSD-T-151-00013. -Shaded areas indicate that no data entry is required.
-For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken.
* This Selector Switch 12 reading is from the upper Selector Switch for S-105.
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
49 of 61
Data Sheet 12: 241-SX Farm Quarterly TMACS Temperatures
Sheet ___ of ___
Tank Tree Instrument
Type
OSD
Limit F
Selector Switch Position
1 2 3 4 5 6 7 8
101
Riser 15 N/A J 280
102
Riser 16 N/A J 280
103
Riser 2 N/A J 205
104
Riser 2 N/A J 280
105
Riser 2 N/A J 280
106
Riser 16 N/A K 280
107
Riser 10 2 J 280
107
Riser 14 8 J 280
Comments:
M&TE
Instrument Model #: Signature Print Name
(First and Last) Date
Instrument ID #: Operator:
Calibration Due Date: Shift Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule.
- Temperature Limits are established per OSD-T-151-00013.
- Shaded areas indicate that no data entry is required. - For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken.
(Data Sheet 12 - Continued on Next Page)
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
50 of 61
Data Sheet 12: 241-SX Farm Quarterly TMACS Temperatures (Cont.)
Sheet ___ of ___
Tank Tree Instrument
Type
OSD
Limit F
Selector Switch Position
1 2 3 4 5 6 7 8
108
Riser 10 2 J 280
108
Riser 19 8 J 280
109
Riser 10 2 J 280
109
Riser 19 8 J 280
110
Riser 12 2 J 280
110
Riser 20 8 J 280
111
Riser 10 2 J 280
111
Riser 19 8 J 280
Comments:
M&TE
Instrument Model #:
Signature Print Name
(First and Last) Date
Instrument ID #:
Operator:
Calibration Due Date:
Shift Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule.
- Temperature Limits are established per OSD-T-151-00013.
- Shaded areas indicate that no data entry is required. - For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken.
(Data Sheet 12 - Continued on Next Page)
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
51 of 61
Data Sheet 12: 241-SX Farm Quarterly TMACS Temperatures (Cont.)
Sheet ___ of ___
Tank Tree Instrument
Type
OSD
Limit F
Selector Switch Position
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
112
Riser 10 2 J 280
112
Riser 19 8 J 280
113
Riser 3 N/A J 280
114
Riser 10 2 J 280
114
Riser 19 8 J 280
Comments:
M&TE
Instrument Model #:
Signature Print Name
(First and Last) Date
Instrument ID #:
Operator:
Calibration Due
Date:
Shift
Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule.
- Temperature Limits are established per OSD-T-151-00013.
- Shaded areas indicate that no data entry is required. - For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken.
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
52 of 61
Data Sheet 13: 241-T Farm Quarterly TMACS Temperatures
Sheet ___ of ___
Tank Instrument
Type
OSD
Limit F
Selector Switch Position
1 2 3 4 5 6 7 8 9 10 11
101
Riser 8 J 280
103
Riser 8 J 280
104
Riser 4 J 280
106
Riser 8 J 280
107
Riser 4 J 280
108
Riser 4 J 280
109
Riser 8 J 280
Comments:
M&TE
Instrument Model #:
Signature Print Name
(First and Last) Date
Instrument ID #:
Operator:
Calibration Due Date:
Shift Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule.
- Temperature Limits are established per OSD-T-151-00013.
- Shaded areas indicate that no data entry is required. - For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken.
(Data Sheet 13 - Continued on Next Page)
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
53 of 61
Data Sheet 13: 241-T Farm Quarterly TMACS Temperatures (Cont.)
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule.
- Temperature Limits are established per OSD-T-151-00013. - Shaded areas indicate that no data entry is required.
- For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken.
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
54 of 61
Data Sheet 14: 241-TX Farm Quarterly TMACS Temperatures
Sheet ___ of ___
Tank Instrument
Type
OSD
Limit F
Selector Switch Position
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
102
Riser 4 J 280
103
Riser 4 J 280
104
Riser 4 J 280
105
Riser 4 J 280
106
Riser 4 J 280
107
Riser 4 J 280
108
Riser 4 J 280
Comments:
M&TE
Instrument Model #:
Signature Print Name
(First and Last) Date
Instrument ID #: Operator:
Calibration Due
Date:
Shift
Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule. - Temperature Limits are established per OSD-T-151-00013.
- Shaded areas indicate that no data entry is required. - For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken.
- Instrument Tech needed to obtain Temperature readings for TX-109.
(Data Sheet 14 - Continued on Next Page)
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
55 of 61
Data Sheet 14: 241-TX Farm Quarterly TMACS Temperatures (Cont.)
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule. - Temperature Limits are established per OSD-T-151-00013.
- Shaded areas indicate that no data entry is required.
- For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken.
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
56 of 61
Data Sheet 15: 241-TY Farm Quarterly TMACS Temperatures
Sheet ___ of ___
Tank Instrument
Type
OSD
Limit F
Selector Switch Position
1 2 3 4 5 6 7 8 9 10 11 12 13 14
101
Riser 4 J 280
102
Riser 4 J 280
103
Riser 4 J 280
104
Riser 4 J 280
105
Riser 3 J 280
106
Riser 2 J 280
Comments:
M&TE
Instrument Model #: Signature Print Name
(First and Last) Date
Instrument ID #: Operator:
Calibration Due Date: Shift Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule. - Temperature Limits are established per OSD-T-151-00013.
- Shaded areas indicate that no data entry is required.
- For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken.
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
57 of 61
Data Sheet 16: 241-U Farm Quarterly TMACS Temperatures
Sheet ___ of ___
Tank Instrument
Type
OSD
Limit F
Selector Switch Position
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
101
Riser 2 J 280
102
Riser 1 J 280
103
Riser 1 J 280
105
Riser 1 J 280
106
Riser 1 J 280
107
Riser 1 J 280
108
Riser 1 J 280
109
Riser 1 J 280
Comments:
M&TE
Instrument Model #: Signature Print Name
(First and Last) Date
Instrument ID #: Operator:
Calibration Due Date: Shift Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule.
- Temperature Limits are established per OSD-T-151-00013. - Shaded areas indicate that no data entry is required.
- For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken.
(Data Sheet 16 - Continued on Next Page)
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
58 of 61
Data Sheet 16: 241-U Farm Quarterly TMACS Temperatures (Cont.)
Sheet ___ of ___
Tank Instrument
Type
OSD
Limit F
Selector Switch Position
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
110
Riser 1 J 280
111
Riser 5 J 280
112
Riser 5 J 280
201
Riser 4 J 280
202
Riser J 280
203
Riser 4 J 280
204
Riser 4 J 280
Comments:
M&TE
Instrument Model #: Signature Print Name
(First and Last) Date
Instrument ID #: Operator:
Calibration Due Date: Shift
Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule.
- Temperature Limits are established per OSD-T-151-00013.
- Shaded areas indicate that no data entry is required. - For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken.
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
59 of 61
Data Sheet 17: 241-BY Farm Quarterly RTD Temperatures
Sheet ___ of ___
Tank Instrument
Type
OSD
Limit F
1 2 3 4 5 6 7 8
103
Riser 5 RTD 280
107
Riser 5 RTD 280
108
Riser 3 RTD 280
Comments:
Data Collection Instruments
Instrument Model #:
Signature Print Name
(First and Last) Date
Instrument ID #:
Operator:
Calibration Due Date:
Shift Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule.
- Temperature Limits are established per OSD-T-151-00013. - Shaded areas indicate that no data entry is required.
- For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken.
- Readings taken by Instrument Techs.
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
60 of 61
Data Sheet 18: 241-T Farm Quarterly RTD Temperatures
Sheet ___ of ___
Tank Instrument
Type
OSD
Limit F
1 2 3 4 5 6 7 8
107
Riser 5 RTD 280
Comments:
M&TE
Instrument Model #: Signature Print Name
(First and Last) Date
Instrument ID #: Operator:
Calibration Due Date: Shift Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule.
- Temperature Limits are established per OSD-T-151-00013.
- Shaded areas indicate that no data entry is required. - For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken.
- Readings taken by Instrument Techs.
Obtain And Record Single-Shell Tank Temperature Data
Type
CONTINUOUS Document No.
TO-040-650 Rev/Mod
H-7 Release Date
01/03/2019 Page
61 of 61
Data Sheet 19: 241-TY Farm Quarterly RTD Temperatures
Sheet ___ of ___
Tank Instrument
Type
OSD
Limit F
1 2 3 4 5 6 7 8
101
Riser 3 RTD 280
103
Riser 7 RTD 280
104
Riser 3 RTD 280
Comments:
M&TE
Instrument Model #: Signature Print Name
(First and Last) Date
Instrument ID #: Operator:
Calibration Due Date: Shift Manager:
Note - Waste solution temperature surveillance is required per WAC 173-303-320 and SST Dangerous Waste Inspection Schedule.
- Temperature Limits are established per OSD-T-151-00013.
- Shaded areas indicate that no data entry is required. - For Tank Temperatures that report to TMACS field readings are not required unless the Tank Temperature fails to report, then a field reading must be taken.