Top Banner
V I S I O N C A R E 1 out of 5 CHILDREN HAS A VISION ISSUE 1 An easy-to-use portable vision screener that is revolutionizing early detection of vision disorders in children. Welch Allyn Spot™ Vision Screener
4

Spot™ Vision Screener - Welch Allyn · ©2018 WELCH ALLYN, INC. ALL RIGHTS RESERVED. DOC. NO: SM4119-EU-R2 MC15451 2018-10 The Spot Vision Screener is intended to produce optical

Jul 13, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Spot™ Vision Screener - Welch Allyn · ©2018 WELCH ALLYN, INC. ALL RIGHTS RESERVED. DOC. NO: SM4119-EU-R2 MC15451 2018-10 The Spot Vision Screener is intended to produce optical

VISION CARE

1 out of 5CHILDREN HAS A VISION ISSUE1

An easy-to-use portable vision screener that is revolutionizing early detection of vision disorders in children.

Welch AllynSpot™ Vision Screener

Page 2: Spot™ Vision Screener - Welch Allyn · ©2018 WELCH ALLYN, INC. ALL RIGHTS RESERVED. DOC. NO: SM4119-EU-R2 MC15451 2018-10 The Spot Vision Screener is intended to produce optical

17% of children in

Europeare visually impaired1

2 to 5%of children

are a� ected byamblyopia7

95%of children with

amblyopiacan be curedwhen treated

before the ageof 4 years8

RECOVERYof children with

amblyopia isvirtually

impossibleafter the age of

8 years8

FUTURETODAY

“Automated vision screeners have better testability in children than traditional vision charts and allow screening of children that cannot be screened with visual acuity testing.”Ahmed M. Kassem, MD “Automated Vision Screening”, Advances in Ophthalmology and Optometry Journal 3 (2018) 87-100

97%Success Rate

Clinically Proven to Be More E� cientEvidence shows that using the Spot Vision Screener can help to dramatically reduce the time required to test vision over traditional screening tools.2

Help Prevent Amblyopia:

Clinically Proven to Have High AccuracyA clinical study has shown Spot Vision Screener to have 92.6% sensitivity and 90.6% specifi city.3

Nearly 80% of preschool age* childrennever get an eye examination5

Clinically Proven to Have High Success RateSpot Vision Screener has been shown to have a high success rate, capturing readings 97% of the time.4

92.6% 90.6%

Percentage of patients correctly identifi ed as

having a vision condition.

Percentage of patients correctly identifi ed as not having a vision condition.

6 months - 3 years(pre-verbal)Ideal stage to detect amblyopic precursors

4 - 8 years(assess school readiness) Final opportunity to detectand correct amblyopic conditions through refractive measurements

9 - 15 years(adolescence) Changes in vision are common as the body grows; 1 in 46 children at this age have a vision issue

*Preschool age varies in age from country to country.

Sensitivity Spec

ifici

ty

Spot Vision Screener technology is changing the way routine vision screening is done.

Page 3: Spot™ Vision Screener - Welch Allyn · ©2018 WELCH ALLYN, INC. ALL RIGHTS RESERVED. DOC. NO: SM4119-EU-R2 MC15451 2018-10 The Spot Vision Screener is intended to produce optical

Just a few seconds can help positively impact a child’s future

Spot Vision Screener

• Easy to use, easy to implement with minimal user training required

• Doesn’t require eye dilation

• Screens both eyes at once from a nonthreatening 1-meter distance

• Durable touchscreen display

• Uses lights and sounds to help engage children

• Provides thorough, objective and easy-to-understand results

• WiFi® connectivity and USB port to print and import/export data or settings

• Fully portable device, handheld and battery-operated

• Powered by rechargeable battery or direct power cord

SCREEN YOURPATIENT

REFER TO ANEYE SPECIALIST,

IF NEEDED

GET ACUSTOMIZED

REPORT

Objective and Consistent Care

• Detect pre-amblyopic and amblyopic risk factors much easier and earlier compared to traditional screening tests

• Pass/Refer results are immediately available

Superior User and Patient Experience

• Touchscreen display makes it easy to screen and read results

• Requires minimal sta� training and minimal cooperation from the patient

Coordination of Care

• Import/export patient data into records

• One-page vision screening summary reports help educate parents and inform follow-up decisions

1. 2. 3.

REPORT

Here’s what Spot Vision Screener can detect:

MyopiaNear-sightedness

HyperopiaFar-sightedness

AnisometropiaUnequal refractive power

AstigmatismBlurred vision, eye structure problem

StrabismusEye misalignment

AnisocoriaUnequal pupil size

Myopia

HyperopiaHyperopia

power structure problem

tropiatropiatropiatropiaStrab

ismus

Anisocoria

AnisocoriaUnequal pupil size

coria

OSOD

77 6.0mm mm

6.0mm

0°0°

0°0°

Complete Eye Exam RecommendedMyopia (OD/OS)

Retry PrintSummaryEditMono

02/02/2017 2:11 PM

- CYL

R

+2.00 -1.00 @86°

-2.50S E

A x i sD S D C

+2.25 -0.75 @43°

-2.25S E

A x i sD S D C

Home

Experience the Di� erence

Page 4: Spot™ Vision Screener - Welch Allyn · ©2018 WELCH ALLYN, INC. ALL RIGHTS RESERVED. DOC. NO: SM4119-EU-R2 MC15451 2018-10 The Spot Vision Screener is intended to produce optical

Welch Allyn EMEAI Customer CareIDA Business Park - JohnstownNavan, County Meath, Ireland(p) +353 46 906 7700 [email protected]

EMEAI.WELCHALLYN.COM

©2018 WELCH ALLYN, INC. ALL RIGHTS RESERVED. DOC. NO: SM4119-EU-R2 MC15451 2018-10

The Spot Vision Screener is intended to produce optical images that can help identify refractive errors and ocular misalignments by detecting special light refl exes from each eye during screening. The Spot Vision Screener evaluates these light refl exes from the retina to estimate refractive error. It also estimates pupil size, pupil distance and eye gaze deviation. It is intended for use on subjects six months of age through adults. Medical device (93/42/EEC): Class I(m). Manufacturer: Welch Allyn, Inc., 4341 State Street Road, Skaneateles Falls, NY 13153 USA. EC Rep.: Welch Allyn Limited, Navan Business Park, Dublin Road, Navan, County Meath, Republic of Ireland. This medical device is a regulated health product which, pursuant to such regulation bears a CE mark. Welch Allyn recommends that you carefully read the detailed instructions for safe and proper use included in the documents accompanying the medical device. The personnel of healthcare establishments are responsible for the proper use and maintenance of these medical devices. Welch Allyn reserves the right to make changes without notice in design, specifi cations and models. The only warranty Welch Allyn makes is the express written warranty extended on the sale of its products.

Sources:1. The Social And Economic Impact of Poor Vision Paper. Vision Impact Institute. 20102. Palmetto Elementary Case Study. Welch Allyn. 2012-20173. Evaluation of the Spot Vision Screener in young children in Costa Rica. J AAPOS. 2015 Oct;19(5):441-4. doi: 10.1016/j.jaapos.2015.08.0024. Accuracy of the Spot and Plusoptix photoscreeners for detection of astigmatism; 2015, Mabel Crescioni, JD, DrPH, Joseph M. Miller, MD, MPH, and Erin M. Harvey, PhD5. Castanes MS. Major review: The underutilization of vision screening (for amblyopia, optical anomalies and strabismus) among preschool age children. Binocul Vis Strabismus Q 2000; 18: 217–332.6. Zabba, Joel N. “Children’s Vision Care in The 21st Century & Its Impact on Education, Literacy, Social Issues & the Workplace: A Call to Action.” Journal of Behavioral Optometry (2011)7. Schmucker, Christine. E� ectiveness of screening preschool children for amblyopia: a systematic review, July, 20098. AsnaV (Association nationale pour l’amélioration de la Vue) (2013) Soigner l’amblyopie (perte de vision d’un œil) L’importance d’un dépistage et d’une prise en charge précoce (Treat amblyopia—loss of vision of one eye—The importance of

screening and early management) [Press release]. 15 May.

VISION SCREENER

S

VISION CARE

PediaVision is a registered trademark of PediaVision Holdings, LLC. The Spot logo and information in this report are the trademarks and property of PediaVision Holdings, LLC. Copyright ©2012 by PediaVision Holdings, LLC. All rights reserved.

Vision screening does not replace a complete eye examination by an ophthalmologist or optometrist.

P O T E N T I A L C O N D I T I O NVision screeni e.

myopia

hyeropia

astigmatism anis

ocor

ia

anis

omet

ropi

a

gaze

as

ymm

etry

OUT OF RANGE OUT OF RANGE

B O T H E Y E S

Complete Eye ExamRecommended

V i s i o n S c r e e n i n g S u m m a r y

gaze dev.

SUBJECT ID 31076-11234

SCREENING 02/02/2017 2:11 pm

FIRST NAME Daniel

LAST NAME Smith

GENDER M AGE 11Y

LEVY123456789_20170202_174320_OutOfRange_0_100000.pdf PRINTED ON 02-02-2017 4:50 PM

SpotTM Vision ScreenerWWW.WELCHALLYN.COM

•Myopia (OD/OS) [Nearsighted]

OSOD

77 6.0mm mm

6.0mm

0°0°

0°0°

- CYL

R L

+2.00 -1.00 @86°

-2.50S E

A x i sD S D C

+2.25 -0.75 @43°

-2.25S E

A x i sD S D C

Welch Allyn is a registered trademark of Welch Allyn, Inc. Information in this report is property of Welch Allyn. Copyright © 2014 by Welch Allyn. All rights reserved.

EMR

For more information on how to improve patient outcomes and help save vision in children and adults contact your local Welch Allyn representative. Learn more at emeai.welchallyn.com Spot Vision

Screener Microsite

VS100-2 Spot Vision Screener, EU power supply and cord, wrist strap VS100-4 Spot Vision Screener, UK power supply and cord, wrist strap VS100S-2 Spot Vision Screener, EU power supply and cord, wrist strap and carry caseVS100S-4 Spot Vision Screener, UK power supply and cord, wrist strap and carry case

ACCESSORIES10644 Spot Vision Screener Carry Case

Ordering Information:

Easy export of data for improved documentation and patient care

Customized patient reportUSB port

WiFi

OR

Printed label report Results can be sent directly to EMR