Spectral Imaging X-ray Microanalysis System NORAN System 7 Spectral Analysis Point & Shoot Spectral Imaging COMPASS: Component Analysis of Spectral Images Part of Thermo Fisher Scientific microanalysis
8

Spectral Imaging X-ray Microanalysis System.pdfSpectral Imaging X-ray Microanalysis System NORAN System 7 Spectral Analysis Point & Shoot Spectral Imaging COMPASS: Component Analysis

Apr 24, 2018

Download

Documents

phungliem
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Spectral Imaging X-ray Microanalysis System.pdfSpectral Imaging X-ray Microanalysis System NORAN System 7 Spectral Analysis Point & Shoot Spectral Imaging COMPASS: Component Analysis

Spectral Imaging X-ray Microanalysis System

NORAN System 7

Spectral Analysis

Point & Shoot

Spectral Imaging

COMPASS: Component Analysis of Spectral Images

Part of Thermo Fisher Scientific

m i c r o a n a l y s i s

Page 2: Spectral Imaging X-ray Microanalysis System.pdfSpectral Imaging X-ray Microanalysis System NORAN System 7 Spectral Analysis Point & Shoot Spectral Imaging COMPASS: Component Analysis

• Automatic Peak Identification Using rule-based identification and peakshape deconvolution, elemental peaks are automatically identified quickly andaccurately.

• Confirm Elements PresentSpectraCheck both visually and statisticallyconfirms the presence of an element usingspectrum simulation and comparison routines to provide both an overlappedspectrum, and a chi-squared value indicating goodness of fit.

• Accurate Peak Intensities Elemental peak references provide a complete set of spectral peak shapes collected with a typical EDS system. Theintensities from these shapes are auto-matically corrected to match the detectoron your microscope, eliminating the needto periodically calibrate the system withstandards.

• Precise Matrix Correction Since 1983 Thermo Scientific X-ray analyzers have been using the PROZAPhi-Rho-Z matrix correction algorithm asimplemented by Bastin et al. This modelof Phi-Rho-Z has been shown to havesuperior performance to all other methodsof matrix correction.

NO

RAN

System 7

X-ray Microanalysis

High Throughput, Impeccable Accuracy and No CompromisesThe Thermo Scientific NORAN System 7 EDS system provides the ultimatein microanalysis capabilities for the modern electron microscopy lab: X-raydetectors with the highest sensitivity, pulse processors and digital imagingwith the highest throughput and the most sophisticated software suiteavailable. Combined together, NORAN System 7 produces accurate resultsand answers in seconds making your lab a better place to work.

Digital Pulse Processing: Compress Your Data Acquisition Time

UltraDry X-ray Detector

NORAN System 7Analyzer

Application Software

The NORAN System 7 redefines X-ray pulseprocessing. Capable of processing morethan 1,000,000 counts per second, the

NORAN System 7 more than doubles previously available count rates. Whether you use Si(Li) or SDD

detectors, NORAN System 7 speeds the pathto answers by reducing the amount of timenecessary to collect data. In addition, processing algorithms and electronics pioneered by Thermo Scientific in 1992 andcontinually developed since then to producespectrum with no peak shift or peak broad-ening, from minimum to maximum count rates.

Page 3: Spectral Imaging X-ray Microanalysis System.pdfSpectral Imaging X-ray Microanalysis System NORAN System 7 Spectral Analysis Point & Shoot Spectral Imaging COMPASS: Component Analysis

Point & ShootPoint & Shoot mode integrates electronimaging and X-ray analysis. A single mouseclick provides both elemental identificationand quantitative analysis of the selectedareas of interest of the sample.

Areas on the sample are defined usingpoints, rectangles, circles, polygon or with amagic wand tool. The magic wand tool allowsyou to easily and instantly outline complexareas without having to manually draw aborder. The selection, based on gray levels,is made automatically with just one click.The selected areas may be analyzed instantlyor multiple areas may be selected for automated analysis. Point & Shoot performsprocessing according to your settings. WithPoint & Shoot everything you need is in oneplace. From qualitative to quantitativeanalysis with full standards, Point & Shootis the easiest place to get the spectralresults you need.

Getting to the answer quickly and accurately is critical in today’smicroscopy laboratory. Often you must answer the question of “What is the composition at one or more areas of the sample?”

Multiple spectral processing and analysis steps are performed automaticallyas part of the acquisition

Your Results

Point & Shoot image overlaid with a user-drawn polygon shape and an automatic magic wand shape

Comparison report of spectra collected from differentshapes on a single Point & Shoot image

Page 4: Spectral Imaging X-ray Microanalysis System.pdfSpectral Imaging X-ray Microanalysis System NORAN System 7 Spectral Analysis Point & Shoot Spectral Imaging COMPASS: Component Analysis

NO

RAN

System 7

X-ray Microanalysis

Spectral Imaging provides for the display ofany number of element maps, both duringand after the acquisition. It includes a richset of data extraction and analysis functionsfor interpreting the data.

Many methods exist to select spectrafor analysis from a Spectral Imaging dataset –in fact the only limit is your imagination.Because every spectrum from the dataset is fully deadtime corrected during the acquisition, each spectrum can be used forstandardless or full standards quantitativeanalysis. A single button selection changesthe display from a summed spectrum to amaximal spectrum.

Spectral Imaging Data Extraction Tools: • Rectangle• Magic Wand, a unique tool that allows

the selection of areas by gray levels• Circle• Polygon, for freehand drawn areas• Linescans, with variable number of points

and width

Spectral Imaging X-ray MicroanalysisSpectral Imaging has revolutionized x-ray mapping. With a spectrumacquired at every point it is the centerpiece for all imaging, X-ray mapping,Linescan and advanced automated analysis. With one click, the NORANSystem 7 collects data that can be analyzed repeatedly without the needfor re-acquiring or changing acquisition parameters. Once the data is collected, you may choose to analyze it locally at the microscope or takethe data offline to a different computer for report preparation.

Network-Ready Data AnalysisFrom its inception, the NORAN System 7 was designed for theeasy transfer of information over a data network. This allowsthe microscopist to analyze data away from the lab.

Projects are stored as folders in Windows® Explorer®,which groups the analyses of samples or sample sets for easyretrieval. NORAN System 7 software can be installed on multiplecomputers using the site license included with every system.Projects can then be conveniently accessed and analyzed fromyour office or any other compatible computer within the facility.Data can also be situated on a Windows Server System™

allowing for backup and support by your local IT group.

The spectral imaging data cube contains an electron image and a spectrum at every point.

Page 5: Spectral Imaging X-ray Microanalysis System.pdfSpectral Imaging X-ray Microanalysis System NORAN System 7 Spectral Analysis Point & Shoot Spectral Imaging COMPASS: Component Analysis

Difficult to interpret sample compositions can nowbe identified effortlessly with the Noran System 7exclusive automatic quantitative mapping. Goingfar beyond simple X-ray maps, Noran System 7sets a new standard in sample analysis. With justone click difficult-to-interpret X-ray maps are transformed into clear elemental maps withoutpeak overlaps or background effects. This fullquantitative analysis is done effortlessly, yet usesthe power of least squares fitting to provide results you will have confidence in every time.

The example shown here displays gross countand weight % maps. When basic X-ray mapping isused, the gross count maps all appear the samedue to peak overlaps between Si, Ta and W. It isonly with the application of full quantitative analysisthat the spatial separation becomes evident. Hadonly basic X-ray mapping been used, an accurateinterpretation of the composition could not bedetermined.

Only the NORAN System 7 produces full quantitative analysisfrom every point in your sample

With the application of full quantitative analysis thespatial separation becomes evident

Without full quantitative analysis, the gross countmaps all appear the same due to peak overlap issues

Gross Count Maps

Weight % Maps

Automatic Quantitative Mapping – Confidence in Your Results

Page 6: Spectral Imaging X-ray Microanalysis System.pdfSpectral Imaging X-ray Microanalysis System NORAN System 7 Spectral Analysis Point & Shoot Spectral Imaging COMPASS: Component Analysis

NO

RAN

System 7

X-ray Microanalysis

COMPASS Multivariate Statistical Analysis Software

1-Click Reporting in all Modes

Just One Click to:• Print report• Open in Microsoft® Office Word• Open in Microsoft Office PowerPoint®

Traditional X-ray microanalysis systemsallow each microscopist to choose the elements for analysis. This can lead to different results form the same sample,depending on who performed the analysis.Have you ever wondered how you could getall of the people in the lab to perform thesame analysis and obtain the consistentresults? COMPASS software is the answer.This additional software tool for use withNORAN System 7 uses powerful multivariatestatistical algorithms as created by PaulKotula et al. and licensed from Sandia

National Labs. COMPASS allows, with asingle click of a button, the automatic andcomplete analysis of a Spectral Imagingdataset.

The results from COMPASS consist of aset of spectrum and component imagesshowing the spatial distribution of the component within the sample. COMPASS isthe ideal tool for anyone wishing to auto-matically analyze spectral images or X-raymaps. Since COMPASS algorithms arelargely free of user input, everyone gets thesame answer, the CORRECT answer.

Page 7: Spectral Imaging X-ray Microanalysis System.pdfSpectral Imaging X-ray Microanalysis System NORAN System 7 Spectral Analysis Point & Shoot Spectral Imaging COMPASS: Component Analysis

Xphase Compositional Distribution Mapping Software

Dual Detector OperationThe NORAN System 7 allows up to two detectors to be attached to a single analyzersystem. Data can be collected in any acquisition mode selecting a single detector orby selecting both detectors. Dual detector operation gives you more than 2,000,000counts per second processing capability. Configurations may include deployment oftwo Si(Li) detectors, two SDD units, or one Si(Li) and one SDD combination.

While analysis using COMPASS is the ultimate in automatic, hands-free SpectralImaging analysis, our Xphase softwaregives you the option to take full control ofthe results.

Xphase software uses any set ofimages of the sample – whether they areraw maps, quantitative maps or COMPASSdistribution images – and calculates whichareas of the sample have nearly the samecomposition. It then creates a binary imagefor the each area. Spectra representingeach of the resultant phases is extractedfrom the Spectral Imaging data cube byusing the binary images as a mask. Theresult is that with little effort you determinewhich areas of the sample have the samecomposition, and then generate images andspectra representing those areas.

• Pulse Processor Rate – Dynamicallyadjusts the analyzer to the conditions of the microscope. Simply adjust themicroscope for the optimum image andNORAN System 7 adjusts accordingly.

• Peak Suppression – The Zero Peak is auseful diagnostic tool. When it is notneeded, NORAN System 7 removes itfrom view so you can concentrate on theelemental data.

• High keV Cutoff – NORAN System 7only acquires the data that is necessaryeconomizing on storage space and processing speed.

• Acquisition Time – Acquisition timesbased on statistics, rather than fixedtime, ensure that the data collected issignificant.

• Brightness/Contrast – There is no needto fine tune the image brightness andcontrast – NORAN System 7 does it for you.

• Drift Compensation Time – Optimizesthe time between compensation cyclesimproving data throughput.

In traditional X-ray microanalysis systems, managing the optimal acquisition condition is atrial-and-error process. The NORAN System 7 monitors the acquisition and fine tunes the system during operation to ensure that the best data is collected every time an acquisition isstarted. Guesswork and rework are eliminated.

Automatic Acquisition Management

A concise report shows where a phase or compound is located and the associated spectra

Page 8: Spectral Imaging X-ray Microanalysis System.pdfSpectral Imaging X-ray Microanalysis System NORAN System 7 Spectral Analysis Point & Shoot Spectral Imaging COMPASS: Component Analysis

BR51427_E 12/07M

Thermo Electron Scientific Instruments LLC, Madison, WI USA is ISO Certified.

©2007 Thermo Fisher Scientific Inc. All rights reserved.DigitalMicrograph is a trademark of Gatan, Inc.Microsoft, PowerPoint, Windows and Explorer are registered trademarks of Microsoft Corp. WindowsServer System is a trademark of Microsoft Corp. Allother trademarks are the property of Thermo FisherScientific Inc. and its subsidiaries.

Specifications, terms and pricing are subject to change.Not all products are available in all countries. Pleaseconsult your local sales representative for details.

In addition to these offices, ThermoFisher Scientific maintains a network of representative organizationsthroughout the world.

Africa+43 1 333 5034 127 • [email protected]

Australia+61 2 8844 9500 • [email protected]

Austria+43 1 333 50340 • [email protected]

Belgium+32 2 482 30 30 • [email protected]

Canada+1 800 530 8447 • [email protected]

China+86 10 5850 3588 • [email protected]

Denmark+45 70 23 62 60 • [email protected]

Europe-Other+43 1 333 5034 127 • [email protected]

France+33 1 60 92 48 00 • [email protected]

Germany+49 6103 408 1014 • [email protected]

India+91 22 6742 9434 • [email protected]

Italy+39 02 950 591 • [email protected]

Japan+81 45 453 9100 • [email protected]

Latin America+1 608 276 5659 • [email protected]

Middle East+43 1 333 5034 127 • [email protected]

Netherlands+31 76 587 98 88 • [email protected]

South Africa+27 11 570 1840 • [email protected]

Spain+34 914 845 965 • [email protected]

Sweden / Norway / Finland+46 8 556 468 00 • [email protected]

Switzerland+41 61 48784 00 • [email protected]

UK+44 1442 233555 • [email protected]

USA+1 800 532 4752 • [email protected]

www.thermo.com

COMPASSAutomatically analyze Spectral Imagingdatasets resulting in component images andspectra. The fastest method for all users toobtain the correct result from the analysis.

XphaseProvides full control of the process fordetermining compounds and phases withina sample. Allows the usage of X-ray maps,quantitative maps, COMPASS and electronimages to determine areas that define areasof similar composition.

Column CommunicationCommunicates with the electron microscopevia serial or Ethernet connections to auto-matically retrieve the magnification, kV andworking distance each time data is acquiredfrom the sample.

AutomationSample analysis at multiple areas usingstage automation. Up to 6 axes can be automated. Each mode of NORAN System 7uses the same automation interface makingrepetitive analyses direct and simple.

MatchUniquely identifies a spectrum by comparingits shape to that of other spectra in a database. Match is provided with an alloydatabase of more than 300 compounds. Add your own additional Match standardsusing measured spectra or numeric quantitative values.

Direct-To-PhaseCombines the functions of COMPASS,Xphase and Match to automatically analyzeSpectral Imaging data sets during the acquisition. In one step the entire acquisitionand analysis is completed providing compound/phase images and spectra. When the final result is achieved, no furtherprocessing is needed. Simply click thereport button.

Drift CompensationAutomatically compensate for image orstage drift. Allows for extended acquisitionson all SEMs or STEMs.

Feature SizingParticle/inclusion analysis and chemicalidentification determines the morphologyand composition of identifiable features in a sample. Combined with the Automationtool, the Feature Sizing tool can be used to perform unattended particle/inclusionanalysis.

PortalIntegration with third party applicationssuch as Gatan DigitalMicrograph™, Probe For Windows or FEI EMISPEC ESV.

NORAN System 7 Options

NORAN System 7 provides the ultimate in power, flexibility and ease –even when analyzing complex samples. Included with the powerful digitalpulse processing and digital imaging hardware is a suite of software unparalleled in the industry. Revolutionary software tools enable users toeliminate tedious manual data extraction steps and multiple softwarelicenses allow users to access and analyze data from computers outside thelab. With state-of-the-art algorithms for spectral and spectral image analysisyou can quickly generate the information you need and have confidence inyour results. The following options can further enhance the productivity ofyour NORAN System 7 EDS system.