7100, 7101 Electric Strikes Specifications FAIL-SAFE/FAIL-SECURE • Field convertible from one mode to the other. However, AC intermittent solenoid must not be used continuously in either. CASE • Approximately 1" x 3-3/8" x 1-5/8" deep. STRIKE LIP • Basic 7100 strike has lip of proper length for 1-3/4" thick door that closes flush with jamb edge. Where door thickness or jamb shape differs from this standard relationship, lip extension kits are available, specified by last dash number. Not available on 7101. STRIKE OPENING • 5/8" x 1-7/16" x 1/2" deep. Bolt retainer jaw is stainless steel. Strike accepts bolt of any Adams Rite 4500, 4700 (discontinued), or 4900 Deadlatch or cylindrical latches. FACEPLATE • Measures 1-1/4” x 4-7/8”. 7100 has flat faceplate; 7101 is radiused to match nose on inactive leaf in a pair of narrow stile glass doors. Available in a wide range of architectural finishes. VOLTAGE • Available in 12 or 24 volt AC and DC. DC continuous units are silent, AC intermittent units “buzz" on operation. CURRENT DRAW/AMPS VOLTS AC INTERMITTENT DC CONTINUOUS 12 1.42 0.33 24 0.74 0.17 STANDARD PACKAGE • Individually boxed with mounting screws, mounting clips, adhesive shims to accommodate jamb or stile extrusion thickness greater or less than nominal 1/8". OPTIONS • Available with two monitoring signal switches which sense whether latchbolt is in strike and whether strike jaw is blocked. Choice of mounting in AC and DC for intermittent or continuous duty. 7100 Electric Strike (flat faceplate) available with extended strike lip. Specify assembled for either fail-secure (locked when unpowered) or fail- safe (locked when powered) operation, but can be field converted to the other mode. 7100, 7101 ELECTRIC STRIKES ALUMINUM UL BURGLARY LISTED ELECTRIFIED PRODUCT GRADE 1 E09321 7100, 7101 Electric Strikes with 4-7/8" faceplates are designed for Adams Rite deadlatches or cylindrical locksets with 1/2" to 5/8" latchbolt projection. For use in aluminum jambs and stiles. Function Remote electrical control of any door equipped with an Adams Rite 4500, 4700, or 4900 Series (or similar) Deadlatch or cylindrical (key-in-knob/lever) type lockset with 1/2" to 5/8" latchbolt projection. Electrical actuation unlocks strike jaw, releasing latchbolt so door can be opened without operating latch itself. Extremely compact mechanism fits into aluminum jamb (or opposing door) sections as shallow as 1-5/8". Fits existing prep for discontinued Adams Rite 7000, 7500, 7800 Electric Strikes. ELECTRIC STRIKES ES-1 800.872.3267 • Fax 800.232.7329 10027 S. 51st Street, Ste 102 Phoenix, Arizona 85044 www. adamsrite.com ARM-014-9/14
30
Embed
Specifications 7100, 7101 FAIL-SAFE/FAIL-SECURE … · 7100, 7101 Electric Strikes Specifications FAIL-SAFE/FAIL-SECURE • Field convertible from one mode to the other. However,
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
7100, 7101 Electric Strikes
SpecificationsFAIL-SAFE/FAIL-SECURE• Field convertible from one mode to the other.
However, AC intermittent solenoid must not be used continuously in either.
CASE• Approximately 1" x 3-3/8" x 1-5/8" deep.
STRIKE LIP• Basic 7100 strike has lip of proper length for 1-3/4" thick
door that closes flush with jamb edge. Where door thickness or jamb shape differs from this standard relationship, lip extension kits are available, specified by last dash number. Not available on 7101.
STRIKE OPENING• 5/8" x 1-7/16" x 1/2" deep. Bolt retainer jaw is stainless
steel. Strike accepts bolt of any Adams Rite 4500, 4700 (discontinued), or 4900 Deadlatch or cylindrical latches.
FACEPLATE• Measures 1-1/4” x 4-7/8”. 7100 has flat faceplate; 7101
is radiused to match nose on inactive leaf in a pair of narrow stile glass doors. Available in a wide range of architectural finishes.
VOLTAGE• Available in 12 or 24 volt AC and DC. DC continuous units
are silent, AC intermittent units “buzz" on operation.
CURRENT DRAW/AMPSVOLTS AC INTERMITTENT DC CONTINUOUS
12 1.42 0.33
24 0.74 0.17
STANDARD PACKAGE• Individually boxed with mounting screws, mounting clips,
adhesive shims to accommodate jamb or stile extrusion thickness greater or less than nominal 1/8".
OPTIONS• Available with two monitoring signal switches which sense
whether latchbolt is in strike and whether strike jaw is blocked. Choice of mounting in AC and DC for intermittent or continuous duty. 7100 Electric Strike (flat faceplate) available with extended strike lip. Specify assembled for either fail-secure (locked when unpowered) or fail-safe (locked when powered) operation, but can be field converted to the other mode.
7100, 7101 ELECTRIC STRIKES
ALUMINUM UL BURGLARY
LISTED
ELECTRIFIED PRODUCT
GRADE 1 E09321
7100, 7101 Electric Strikes with 4-7/8" faceplates are designed for Adams Rite deadlatches or cylindrical locksets with 1/2" to 5/8" latchbolt projection. For use in aluminum jambs and stiles.
FunctionRemote electrical control of any door equipped with an Adams Rite 4500, 4700, or 4900 Series (or similar) Deadlatch or cylindrical (key-in-knob/lever) type lockset with 1/2" to 5/8" latchbolt projection. Electrical actuation unlocks strike jaw, releasing latchbolt so door can be opened without operating latch itself. Extremely compact mechanism fits into aluminum jamb (or opposing door) sections as shallow as 1-5/8". Fits existing prep for discontinued Adams Rite 7000, 7500, 7800 Electric Strikes.
ELECTRIC STRIKES ES-1
800.872.3267 • Fax 800.232.7329
10027 S. 51st Street, Ste 102 Phoenix, Arizona 85044
www.adamsrite.comARM-014-9/14
VERTICAL OF ELECTRICSTRIKE FACEPLATE DIRECTLY OPPOSITE OF DEADLATCH
RADIUS FACEOF 7101
PRESSEDMETAL NUT
MOUNTINGCLIP PRESSURE
SENSITIVESPACER
TURN STRIKE UPSIDE DOWN
FOR OPPOSITE HAND
JAMB
HORIZONTAL OF ELECTRIC STRIKEAND LATCHBOLT
R
(4 PLACES)
DRILL & CSKFOR 8-32 SCREW(2 PLACES)
JAMBEDGE “A”
1-15/32"37.3mm
1/4"6.4mm
1"25.4mm
1-1/8"28.6mm
1-1/4"31.8mm
1-1/4"31.8mm
3/32"2.4mm
1-5/8"41.3mm
4-1/8"104.8mm
4-7/8"123.8mm
4-7/8"123.8mm
6-1/8"155.8mm
5/32"4mm
3-3/8"85.7mm
3-3/8"85.7mm
3-3/8"85.7mm
21/32"16.7mm
1-7/16"36.5mm
1-1/16"27mm
2-5/8"66.7mm
21/32"16.7mm
CYLINDER OF ADAMS RITE
LATCH
“A”
STANDARD UNIT FITS DIM. “A” UP TO 1-1/16"(SEE HOW TO ORDER)
MOUNTING BRACKETS FURNISHED
7100, 7101 ELECTRIC STRIKES
Dimensions Jamb Preparation
RELATED PRODUCTS When purchasing this product, please consider the following related products, available separately:
SpecificationsFAIL-SAFE/FAIL-SECURE• Field convertible from one mode to the other.
However, AC intermittent solenoid must not be used continuously in either.
CASE• Approximately 1" x 3-3/8" x 1-5/8" deep.
STRIKE LIP• Basic 7110 strike has lip of proper length for 1-3/4"
thick door that closes flush with jamb edge. Where door thickness or jamb shape differs from this standard relationship, lip extension kits are available, specified by last dash number.
STRIKE OPENING• 5/8" x 1-7/16" x 1/2" deep. Bolt retainer jaw is stainless
steel. Strike accepts bolt of any Adams Rite 4500, 4700 (discontinued), or 4900 Deadlatch or cylindrical latches.
FACEPLATE• 7110 faceplate measures 1-7/16” x 7-15/16”. 7111
faceplate measures 1-7/16” x 10-1/4”. Available in a wide range of architectural finishes.
VOLTAGE• Available in 12 or 24 volt AC and DC. DC continuous units
are silent, AC intermittent units “buzz" on operation.
CURRENT DRAW/AMPSVOLTS AC INTERMITTENT DC CONTINUOUS
12 1.42 0.33
24 0.74 0.17
STANDARD PACKAGE• Individually boxed with mounting screws, mounting
clips, and adhesive shims to accommodate jamb or stile extrusion thickness greater or less than nominal 1/8".
OPTIONS• Available with two monitoring signal switches which sense
whether latchbolt is in strike and whether strike jaw is blocked. Choice of voltage in AC and DC for intermittent or continuous duty. Specify assembled for either fail-secure (locked when unpowered) or fail-safe (locked when powered) operation, but can be field converted to the other mode. Model 7110 and 7111 are identical except for their faceplate length.
7110, 7111 ELECTRIC STRIKES
7110 Electric Strike with 7-15/16" faceplate and 7111 Electric Strike with 10-1/4" faceplate are designed for Adams Rite deadlatches or cylindrical locksets with 1/2" to 5/8" latchbolt projection. For use in hollow metal, wood and aluminum door jambs.
FunctionReplaces earlier 002, 7510, or 7810 electric releases in either metal or wood jambs for remote electrical control of any door equipped with an Adams Rite 4500, 4700, or 4900 Series (or similar) Deadlatch or cylindrical (key-in-knob/lever) type lockset with 1/2" to 5/8" latchbolt projection. Electrical actuation unlocks strike jaw, releasing latchbolt so door can be opened without operating latch itself. Extremely compact mechanism fits into jamb sections as shallow as 1-5/8".
ALUMINUM HOLLOWMETAL
WOOD UL BURGLARY
LISTED
ELECTRIFIED PRODUCT
GRADE 1 E09321
ELECTRIC STRIKES ES-3
800.872.3267 • Fax 800.232.7329
10027 S. 51st Street, Ste 102 Phoenix, Arizona 85044
www.adamsrite.comARM-014-9/14
HORIZONTAL OF ELECTRIC STRIKE
HORIZONTAL OF
CYLINDER (A-R 4500/4900
SERIESDEADLATCH)
VERTICAL OF ELECTRIC STRIKE
FACEPLATE DIRECTLY OPPOSITE OF
DEADLATCH SERIES4500/4900
TURN STRIKE UPSIDE DOWN FOR OPPOSITE HAND
“A”
HORIZONTAL OF ELECTRIC STRIKE
HORIZONTALOF CYLINDER
(A-R 4500/4900 SERIESDEADLATCH)
DRILL & CSKFOR 8-32 SCREW
(2 PLACES)
VERTICAL OF ELECTRIC STRIKE
FACEPLATE DIRECTLY OPPOSITE OF DEADLATCH
R
(4 PLACES)
5/32"4mm
1-7/16"36.5mm
21/32"16.7mm
“A”
1-15/32"37.3mm
1/4"6.4mm
1"25.4mm
1-1/8"28.6mm
1-5/8"41.3mm
1-1/16"27mm 21/32"
16.7mm
1-7/16"36.5mm
3/32"2.4mm
7110:7-15/16"201.6mm
7110:7-15/16"201.6mm
1-7/16"36.5mm
7110:9-3/16"233.4mm
7111:10-1/4"260.4mm
7111:9-29/64"240.2mm
7111:11-1/2"292.1mm
7110:7-7/16"188.9mm
7111:9-29/64"240.1mm
7110:7-15/16"201.6mm
7111:10-1/4"260.4mm
7111:10-1/8"257.2mm
JAMBEDGE “A”
6-7/8"174.6mm
3-3/8"85.7mm
3-3/8"85.7mm 1-3/16"
30.23mm1-3/64"26.6mm
3-3/8"85.7mm
3-3/8"85.7mm
1-41/64"41.7mm
21/32"16.7mm
17/64"6.7mm
23/32"18.3mm
1-7/16"36.5mm
3/32"2.4mm1-5/64"
27.4mm
1-7/16"36.5mm
STANDARD UNIT FITS DIM. “A” UP TO 1-1/16"(SEE HOW TO ORDER)
MOUNTING BRACKETS FURNISHED
7110, 7111 ELECTRIC STRIKES
RELATED PRODUCTS When purchasing this product, please consider the following related products, available separately:
SpecificationsFAIL-SAFE/FAIL-SECURE• Field convertible from one mode to the other.
However, AC intermittent solenoid must not be used continuously in either.
CASE• Approximately 1" x 3-3/8" x 1-5/8" deep.
STRIKE LIP• Basic 7130 strike has lip of proper length for 1-3/4" thick
door that closes flush with jamb edge. Where door thickness or jamb shape differs from this standard relationship, lip extension kits are available, specified by last dash number. Not available for 7131.
STRIKE OPENING• 5/8" x 1-7/16" x 1/2" deep. Bolt retainer jaw is stainless
steel. Strike accepts bolt of any Adams Rite 4500, 4700 (discontinued), or 4900 Deadlatch or cylindrical latches.
FACEPLATE• Measures 1-1/4” x 6-7/8”. 7130 has flat faceplate; 7131
is radiused to match nose on inactive leaf in a pair of narrow stile glass doors. Available in a wide range of architectural finishes.
VOLTAGE• Available in 12 or 24 volt AC and DC. DC continuous units
are silent, AC intermittent units “buzz" on operation.
CURRENT DRAW/AMPSVOLTS AC INTERMITTENT DC CONTINUOUS
12 1.42 0.33
24 0.74 0.17
STANDARD PACKAGE• Individually boxed with mounting screws, mounting clips,
adhesive shims to accommodate jamb or stile extrusion thickness greater or less than nominal 1/8".
OPTIONS• Choice of mounting in AC and DC for intermittent or
continuous duty. 7130 Electric Strike (flat faceplate) available with extended strike lip. Specify assembled for either fail-secure (locked when unpowered) or fail-safe (locked when powered) operation, but can be field converted to the other mode
7130, 7131 ELECTRIC STRIKES
ALUMINUM UL BURGLARY
LISTED
ELECTRIFIED PRODUCT
GRADE 1 E09321
7130, 7131 Electric Strikes with 6-7/8" faceplates are designed for Adams Rite deadlatches or cylindrical locksets with 1/2" to 5/8" latchbolt projection. For use in aluminum jambs and stiles.
FunctionRemote electrical control of any narrow stile or hollow metal door equipped with an Adams Rite Series 4500, 4700, or 4900 Series (or similar) Deadlatch or cylindrical (key-in-knob/lever) type lockset with 1/2" to 5/8" latchbolt projection. Large faceplate is designed to cover strike opening when converting from an MS® pivoted-bolt deadlock to a deadlatch. Electrical actuation unlocks strike jaw, releasing latchbolt so door can be opened without operating latch itself. Extremely compact mechanism fits into aluminum jamb (or opposing door) sections as shallow as 1-5/8". Replaces discontinued Adams Rite 7030, 7530, 7830 Electric Strikes.
ELECTRIC STRIKES ES-5
800.872.3267 • Fax 800.232.7329
10027 S. 51st Street, Ste 102 Phoenix, Arizona 85044
www.adamsrite.comARM-014-9/14
JAMBEDGE “A”
PRESSEDMETAL NUT
MOUNTINGCLIP
PRESSURESENSITIVE
SPACERJAMB
TURN STRIKE UPSIDE DOWN
FOR OPPOSITE HAND.
RADIUS FACEOF 7131
1-15/32"37.3mm 1/4"
6.4mm
2-9/16"65.1mm
1"25.4mm
1-1/8"28.6mm
3-3/8"85.7mm
1-7/16"36.5mm
6-7/8"174.6mm
8-1/4"209.6mm
HORIZONTAL OF ELECTRIC STRIKE
DRILL & CSKFOR 8-32 SCREW
(2 PLACES)
VERTICAL OF ELECTRIC STRIKE
FACE PLATE DIRECTLY
OPPOSITE OF DEADLATCH
HORIZONTAL OF CYLINDER (A-R 4500/4900
SERIES DEADLATCH)
1-1/4"31.8mm
21/32"16.7mm
R
(4 PLACES)
5/32"4mm
1-5/8"41.3mm
1-1/16"27mm 21/32"
16.7mm
1-1/4"31.8mm
3/32"2.4mm
3-3/8"85.7mm
3-3/8"85.7mm
6-7/8"174.6mm
STANDARD UNIT FITS DIM. “A” UP TO 1-1/16"(SEE HOW TO ORDER)
MOUNTING BRACKETS FURNISHED
7130, 7131 ELECTRIC STRIKES
RELATED PRODUCTS When purchasing this product, please consider the following related products, available separately:
SpecificationsFAIL-SAFE/FAIL-SECURE• Field convertible from one mode to the other.
However, AC intermittent solenoid must not be used continuously in either.
CASE• Approximately 1" x 3-3/8" x 1-5/8" deep.
STRIKE LIP• Basic 7140 strike has lip of proper length for 1-3/4"
thick door that closes flush with jamb edge. Where door thickness or jamb shape differs from this standard relationship, lip extension kits are available, specified by last dash number.
STRIKE OPENING• 5/8" x 1-7/16" x 1/2" deep. Bolt retainer jaw is stainless
steel. Strike accepts bolt of any Adams Rite 4500, 4700 (discontinued), or 4900 Deadlatch or cylindrical latches.
FACEPLATE• Measures 1-1/4 x 4-7/8”. Faceplate is flat, with square
corners. Available in a wide range of architectural finishes.
VOLTAGE• Available in 12 or 24 volt AC and DC. DC continuous units
are silent, AC intermittent units “buzz" on operation.
CURRENT DRAW/AMPSVOLTS AC INTERMITTENT DC CONTINUOUS
12 1.42 0.33
24 0.74 0.17
STANDARD PACKAGE• Individually boxed with mounting screws. Includes
mounting clips and adhesive shims for use where welded tabs are omitted.
OPTIONS• Choice of mounting in AC and DC for intermittent or
continuous duty. 7140 Electric Strike (flat faceplate) available with extended strike lip. Specify assembled for either fail-secure (locked when unpowered) or fail-safe (locked when powered) operation, but can be field converted to the other mode.
7140 ELECTRIC STRIKES
7140 Electric Strikes with 4-7/8" faceplates are designed for Adams Rite deadlatches or cylindrical locksets with 1/2" to 5/8" latchbolt projection. For use in hollow metal or wood doors and jambs.
FunctionRemote electrical control of any door equipped with an Adams Rite 4500, 4700, or 4900 Series (or similar) Deadlatch or cylindrical (key-in-knob/lever) type locksets with 1/2" to 5/8" latchbolt projection. Electrical actuation unlocks strike jaw, releasing latchbolt so door can be opened without operating latch itself. Extremely compact mechanism fits into aluminum jamb sections as shallow as 1-5/8". Fits existing prep for discontinued Adams Rite 7040, 7840N, 7850 Electric Strikes.
HOLLOWMETAL
WOOD UL BURGLARY
LISTED
ELECTRIFIED PRODUCT
GRADE 1 E09321
FITS STANDARDMOUNTING
TAB ANSI PREP
3/32"2.4mm
ELECTRIC STRIKES ES-7
800.872.3267 • Fax 800.232.7329
10027 S. 51st Street, Ste 102 Phoenix, Arizona 85044
www.adamsrite.comARM-014-9/14
7140 ELECTRIC STRIKES
RELATED PRODUCTS When purchasing this product, please consider the following related products, available separately:
SpecificationsFAIL-SAFE/FAIL-SECURE• Field convertible from one mode to the other.
However, AC intermittent solenoid must not be used continuously in either.
CASE• Approximately 1" x 3-3/8" x 1-7/8" deep.
STRIKE LIP• Basic 7160 strike has lip of proper length for 1-3/4"
thick door that closes flush with jamb edge. Where door thickness or jamb shape differs from this standard relationship, lip extension kits are available, specified by last dash number.
STRIKE OPENING• 3/4" x 1-7/16" x 5/8" deep. Bolt retainer jaw is stainless
steel. Strike location must be centered on latchbolt.
FACEPLATE• Measures 1-1/4 x 4-7/8”. Faceplate is flat, with radiused
corners. Available in a wide range of architectural finishes.
VOLTAGE• Available in 12 or 24 volt AC and DC. DC continuous units
are silent, AC intermittent units “buzz" on operation.
CURRENT DRAW/AMPSVOLTS AC INTERMITTENT DC CONTINUOUS
12 1.42 0.33
24 0.74 0.17
STANDARD PACKAGE• Individually boxed with mounting screws, mounting clips,
and adhesive shims to accommodate jamb extrusion thickness greater or less than nominal 1/8".
OPTIONS• Available with two monitoring signal switches which sense
whether latchbolt is in strike and whether strike jaw is blocked. Choice of voltage in AC and DC for intermittent or continuous duty. Specify assembled for either fail-secure (locked when unpowered) or fail-safe (locked when powered) operation, but can be field converted to the other mode.
7160 ELECTRIC STRIKE
7160 Electric Strikes with 4-7/8" faceplates are designed for mortise or cylindrical type locksets with up to 3/4" latchbolt projection without deadbolt. For use in aluminum jambs.
FunctionRemote electrical control of any door equipped with a mortise or cylindrical type lockset with up to 3/4" latchbolt projection without deadbolt. Electrical actuation unlocks strike jaw, releasing latchbolt so door can be opened without operating latch itself. Extremely compact mechanism fits into aluminum jamb (or opposing door) sections as shallow as 1-7/8". Fits existing prep for discontinued Adams Rite 7560, 7860 Electric Strikes.
ALUMINUM UL BURGLARY
LISTED
ELECTRIFIED PRODUCT
GRADE 1 E09321
All 3/4" throw latches require 1/8" minimum door gap. Horizontal center line of strike must match line of mortise latchbolt.
ELECTRIC STRIKES ES-9
800.872.3267 • Fax 800.232.7329
10027 S. 51st Street, Ste 102 Phoenix, Arizona 85044
www.adamsrite.comARM-014-9/14
PRESSEDMETAL NUT
MOUNTINGCLIP
PRESSURESENSITIVE
SPACER
TURN STRIKE UPSIDE DOWN
FOR OPPOSITE HAND.
JAMB
20°
1-1/4"31.8mm 3/32"
2.4mm
3-3/8"85.7mm4-1/8"
104.8mm
4-7/8"123.8mm
3-3/8"85.7mm
JAMBEDGE “A”
1/4"6.4mm
1-9/16"39.7mm
1"25.4mm
1-1/8"28.6mm
1-1/2"38.1mm
1-13/16"46mm
1"25.4mm
27/32"21.4mm
HORIZONTAL OF ELECTRIC STRIKE
AND LATCHBOLT(NOT PER STANDARD
ANSI PREP LOCATION)
DRILL & CSKFOR 8-32 FLATHEAD SCREW
(2 PLACES)
VERTICAL OF ELECTRIC STRIKE
FACEPLATE DIRECTLY
OPPOSITE OF DEADLATCH
R
(4 PLACES)
5/32"4mm
3-3/8"85.7mm
6-1/8"155.6mm
4-7/8"123.8mm
1-1/4"31.8mm
27/32"21.4mm
7160 ELECTRIC STRIKE
RELATED PRODUCTS When purchasing this product, please consider the following related products, available separately:
SpecificationsFAIL-SAFE/FAIL-SECURE• Field convertible from one mode to the other.
However, AC intermittent solenoid must not be used continuously in either.
CASE• Approximately 1" x 3-3/8" x 1-7/8" deep.
STRIKE LIP• Basic 7170 strike has lip of proper length for 1-3/4"
thick door that closes flush with jamb edge. Where door thickness or jamb shape differs from this standard relationship, lip extension kits are available, specified by last dash number.
STRIKE OPENING• 5/8" x 1-7/16" x 5/8" deep. Bolt retainer jaw is
stainless steel.
FACEPLATE• Measures 1-1/4 x 4-7/8”. Faceplate is flat, with square
corners. Available in a wide range of architectural finishes.
VOLTAGE• Available in 12 or 24 volt AC and DC. DC continuous units
are silent, AC intermittent units “buzz" on operation
CURRENT DRAW/AMPSVOLTS AC INTERMITTENT DC CONTINUOUS
12 1.42 0.33
24 0.74 0.17
STANDARD PACKAGE• Individually boxed with mounting screws. Includes
mounting clips and adhesive shims for use where welded tabs are omitted.
OPTIONS• Available with two monitoring signal switches which sense
whether latchbolt is in strike and whether strike jaw is blocked. Choice of voltage in AC and DC for intermittent or continuous duty. Specify assembled for either fail-secure (locked when unpowered) or fail-safe (locked when powered) operation, but can be field converted to the other mode.
7170 ELECTRIC STRIKE
7170 Electric Strikes with 4-7/8" faceplates are designed for mortise or cylindrical type locksets with up to 3/4" latchbolt projection without deadbolt. For use in hollow metal or wood door jambs.
FunctionRemote electrical control of any door equipped with a mortise or cylindrical type lockset with up to 3/4" latchbolt projection without deadbolt. Electrical actuation unlocks strike jaw, releasing latchbolt so door can be opened without operating latch itself. Extremely compact mechanism fits into hollow metal jamb sections as shallow as 1-7/8". Fits existing prep for discontinued Adams Rite 7560AN, 7570, 7860AN, 7870 Electric Strikes.
The electric strike must be positioned to accommodate offset mortise latches during installation. Please refer to installation instructions.
HOLLOWMETAL
WOOD UL BURGLARY
LISTED
ELECTRIFIED PRODUCT
GRADE 1 E09321
FITS STANDARDMOUNTING
TAB ANSI PREP
3/32"2.4mm
All 3/4" throw latches require 1/8" minimum door gap. Horizontal center line of strike must match line of mortise latchbolt.
ELECTRIC STRIKES ES-11
800.872.3267 • Fax 800.232.7329
10027 S. 51st Street, Ste 102 Phoenix, Arizona 85044
www.adamsrite.comARM-014-9/14
7170 ELECTRIC STRIKE
RELATED PRODUCTS When purchasing this product, please consider the following related products, available separately:
SpecificationsUL10C, CAN/ULC-S104, FIRE RATED 3 HR.
CASE• Approximately 1" x 3-3/8" x 1-5/8" deep.
STRIKE LIP• Basic 7240 strike has lip of proper length for 1-3/4" thick
door that closes flush with jamb edge.
STRIKE OPENING• 5/8" x 1-7/16" x 9/16" deep. Bolt retainer jaw and
strike lip are stainless steel. Strike accepts bolt from a variety of latchsets.
FACEPLATE• Measures 1-1/4 x 4-7/8”. Faceplate is flat, with
square corners.
VOLTAGE• Available in 12 or 24 volt AC and DC. DC continuous units
are silent, AC intermittent units “buzz" on operation.
CURRENT DRAW/AMPSVOLTS AC INTERMITTENT DC CONTINUOUS
12 1.42 0.33
24 0.74 0.17
STANDARD PACKAGE• Individually boxed with mounting screws. Includes
mounting clips and adhesive shims for use where welded tabs are omitted.
OPTIONS• Available with two monitoring signal switches which sense
whether latchbolt is in strike and whether strike jaw is blocked. Choice of voltage in AC and DC for intermittent or continuous duty. Assembled for fail-secure (locked when unpowered) operation.
7240 FIRE-RATED ELECTRIC STRIKE
7240 Fire-Rated Electric Strikes with 4-7/8" faceplates are designed for cylindrical locksets with up to 5/8" latchbolt projection. For use in hollow metal door jambs.
FunctionRemote electrical control of any door equipped with cylindrical (key-in-knob/lever) type locksets with up to 5/8" latchbolt projection. Electrical actuation unlocks strike jaw, releasing latchbolt so door can be opened without operating latch itself. Extremely compact mechanism fits into jamb sections as shallow as 1-21/32". Fire-rated in fail-secure mode.
HOLLOWMETAL
UL BURGLARY
LISTED
ELECTRIFIED PRODUCT
FIRE RATED HOUR
GRADE 1 E09321
FITS STANDARDMOUNTING
TAB ANSI PREP
3/32"2.4mm
ELECTRIC STRIKES ES-13
800.872.3267 • Fax 800.232.7329
10027 S. 51st Street, Ste 102 Phoenix, Arizona 85044
www.adamsrite.comARM-014-9/14
7240 FIRE-RATED ELECTRIC STRIKE
RELATED PRODUCTS When purchasing this product, please consider the following related products, available separately:
SpecificationsUL10C, CAN/ULC-S104, FIRE RATED 3 HR.
CASE• Approximately 1" x 3-3/8" x 1-7/8" deep.
STRIKE LIP• Basic 7270 strike has lip of proper length for 1-3/4" thick
door that closes flush with jamb edge.
STRIKE OPENING• 3/4" x 1-7/16" x 5/8" deep. Bolt retainer jaw and strike lip
are stainless steel. Strike accepts bolt from a variety of latchsets or mortise panic exit devices when it is centered on strike.
FACEPLATE• Measures 1-1/4” x 4-7/8”. Faceplate is flat, with
square corners.
VOLTAGE• Available in 12 or 24 volt AC and DC. DC continuous units
are silent, AC intermittent units “buzz" on operation.
CURRENT DRAW/AMPSVOLTS AC INTERMITTENT DC CONTINUOUS
12 1.42 0.33
24 0.74 0.17
STANDARD PACKAGE• Individually boxed with mounting screws. Includes
mounting clips and adhesive shims for use where welded tabs are omitted.
OPTIONS• Available with two monitoring signal switches which sense
whether latchbolt is in strike and whether strike jaw is blocked. Choice of voltage in AC and DC for intermittent or continuous duty. Assembled for fail-secure (locked when unpowered) operation.
7270 FIRE-RATED ELECTRIC STRIKES
7270 Fire-Rated Electric Strikes with 4-7/8" faceplates are designed for mortise or cylindrical locksets with up to 3/4" latchbolt projection without a deadbolt. For use in hollow metal door jambs.
FunctionRemote electrical control of any door equipped with a mortise or cylindrical type lockset with up to 3/4" latchbolt projection, without a deadbolt. Electrical actuation unlocks strike jaw, releasing latchbolt so door can be opened without operating latch itself. Extremely compact mechanism fits into jamb sections as shallow as 1-7/8". Fire-rated in fail-secure mode.
FITS STANDARDMOUNTING
TAB ANSI PREP
3/32"2.4mm
All 3/4" throw latches require 1/8" minimum door gap. Horizontal center line of strike must match line of mortise latchbolt.
HOLLOWMETAL
UL BURGLARY
LISTED
ELECTRIFIED PRODUCT
FIRE RATED HOUR
GRADE 1 E09321
ELECTRIC STRIKES ES-15
800.872.3267 • Fax 800.232.7329
10027 S. 51st Street, Ste 102 Phoenix, Arizona 85044
www.adamsrite.comARM-014-9/14
7270 FIRE-RATED ELECTRIC STRIKES
RELATED PRODUCTS When purchasing this product, please consider the following related products, available separately:
SpecificationsFAIL-SAFE/FAIL-SECURE• Field selectable at time of installation.
CASE• Approximately 1" x 3-3/8" x 1-1/16" deep.
STRIKE LIP• Basic 7400 electric strike has lip of proper length for 1-3/4"
thick door that closes flush with jamb edge. Where door thickness or jamb shape differs from this configuration, lip extension kits are available. Not available on 7401.
STRIKE OPENING• 5/8" adjustable x 1-7/16" x 1/2" deep. Bolt retainer jaw is
stainless steel. Strike accepts bolt of Adams Rite 4500, 4700 (discontinued), or 4900 Deadlatch or cylindrical latches.
FACEPLATE• Measures 1-1/4” x 4-7/8”. 7400 has flat faceplate; 7401
is radiused to match nose on inactive leaf in a pair of aluminum stile glass doors. Available in a wide range of architectural finishes.
VOLTAGE• Field selectable to match power source of 12, 16, or 24
VAC/VDC.
CURRENT DRAW/AMPSVOLTS AC INTERMITTENT DC CONTINUOUS
12 0.163 0.440
16 0.228 0.458*
24 0.084 0.230
*Requires 16 DC adapter (P/N VA 7400-16VDC)
STANDARD PACKAGE• Individually boxed with mounting screws, mounting tabs,
adhesive shims to accommodate jamb or stile extrusion thickness greater or less than nominal 1/8", an adjustable jaw shim pack and two plug-in voltage adapters for 12/16/24 VAC and 12/24 VDC.
OPTIONS• Monitoring – Two internally mounted switches (Form “C") to
indicate when the latchbolt is engaged in the strike jaws and a locked/unlocked solenoid status.
• Lip Extension Kits – For various dimensions of door centerline to jamb edge.
• Modular Packaging – Consult factory or sales representative for details.
• 16 VDC Adapter – VA7400-16VDC required when using 16 VDC power.
ULTRALINE 7400, 7401 ELECTRIC STRIKES
7400, 7401 Electric Strikes with 4-7/8" faceplates are designed for Adams Rite deadlatches or cylindrical locksets with 1/2" to 5/8" latchbolt projection. For use in aluminum jambs and stiles. Opens electrically under 35 lbs. of preload.
FunctionRemote electrical control of any door equipped with an Adams Rite 4500, 4700, or 4900 Series (or similar) Deadlatch or cylindrical (key-in-knob/lever) type lockset with 1/2" to 5/8" latchbolt projection. Electrical actuation unlocks strike jaw, releasing latchbolt so door can be opened without operating latch itself. Extremely compact mechanism fits into aluminum jamb (or opposing door) sections as shallow as 1-1/16". Direct upgrade for Adams Rite 7100 Electric Strikes.
This non-handed strike features an ultra-compact design and an adjustable stainless steel split-jaw with 1500 lbs. of holding force in fail-secure mode. The strike releases electrically with up to 35 lbs. of door “preload" (pressure exerted on doors by air conditioning systems, warping or misaligned hardware which can disable common electric strikes). Single solenoid operates on 12, 16, or 24 volt AC/DC power. Strikes are equipped with a quick connect plug-in type connector.
ALUMINUM UL BURGLARY
LISTED
ELECTRIFIED PRODUCT
GRADE 1 E09321
Using jaw inserts of various sizes, the Ultraline 7400 Series electric strikes are adjustable to compensate for door and frame related preload and security problems.
ELECTRIC STRIKES ES-17
800.872.3267 • Fax 800.232.7329
10027 S. 51st Street, Ste 102 Phoenix, Arizona 85044
www.adamsrite.comARM-014-9/14
ULTRALINE 7400, 7401 ELECTRIC STRIKES
RELATED PRODUCTS When purchasing this product, please consider the following related products, available separately:
4500 and 4900 Series Deadlatches. Note that 4700 Deadlatch is discontinued and replaced by 4900 Deadlatch.
Dimensions
RADIUS FACE OF 7401
JAMB
TURN STRIKE UPSIDE DOWN
FOR OPPOSITE HAND
PRESSURESENSITIVE
SPACER
MOUNTINGTAB
PRESSEDMETAL NUT(2 REQD.)
JAMB
12-24 COMBINATIONSCREW (2 REQD.)
8-32 X 3/8 FLAT HEAD SCREW(2 REQD.)
1-1/4"31.8mm
3/32"2.4mm
1-1/16"27mm
1-11/16"42.9mm
1-21/32"42.1mm
4-1/8"104.8mm
3-3/8"85.7mm 3-3/8"
85.7mm4-7/8"123.8mm
“A”
1-13/32"35.7mm
1-1/4"31.8mm
STANDARD UNIT FITS DIM. “A” UP TO 1-1/16"
MOUNTING BRACKETS FURNISHED
“A”
DRILL & CSKFOR 8-32 SCREWS
(2 PLACES)
VERTICAL OF ELECTRICSTRIKE FACEPLATE
DIRECTLY OPPOSITE OF DEADLATCH
R
(4 PLACES)
5/32"4mm
3-3/8"85.7mm
6-1/8"155.6mm
4-7/8"123.8mm
1-7/16"36.5mm
21/32"16.7mm
CYLINDER OF ADAMS
RITE LATCH
HORIZONTAL OF ELECTRICSTRIKE AND LATCHBOLT
Jamb Preparation
Installation
HOW TO ORDER 7400, 7401 ELECTRIC STRIKE Specify quantity and the following information. Order related products separately.
PRODUCT NO. FACEPLATE SHAPE FEATURES FINISH
740 0 M 6280 Flat - None STANDARD FINISHES 629 Bright Stainless
1 Radius M Monitored 313 Dark Bronze Anodized 630 Satin Stainless
A Modular Pack - Body Kit* 335 Black Anodized RITECOAT FINISH (7401 ONLY)
605 Bright Brass 119 To match 335 Black Anodized
606 Satin Brass 121 To match 313 Dark Bronze Anodized
612 Satin Bronze 130 To match 628 Clear Anodized
628 Clear Anodized
Fail-secure can be field converted to fail-safe or vice-versa
*Modular Packing Program - match body kit with faceplate kit to complete. Use 7400A for standard jambs and 7401A for radius stile mounting. No finish designation required.
ES-18 ELECTRIC STRIKES
All measurements are approximate and are provided for informational purposes only. Refer to the product Installation Instructions.
SpecificationsFAIL-SAFE/FAIL-SECURE• Field selectable at time of installation.
CASE• Approximately 1" x 3-3/8" x 1-1/16" deep.
STRIKE LIP• Basic 7400 electric strike has lip of proper length for
1-3/4" thick door that closes flush with jamb edge. Where door thickness or jamb shape differs from this standard relationship, lip extension kits are available.
STRIKE OPENING• 5/8" adjustable x 1-7/16" x 1/2" deep. Bolt retainer jaw is
stainless steel. Strike accepts bolt of Adams Rite 4500, 4700 (discontinued), or 4900 Series Deadlatch or cylindrical latches.
FACEPLATE• 7410 faceplate measures 1-7/16” x 7-15/16”. 7411
faceplate measures 10-1/4”. Available in a wide range of architectural finishes.
VOLTAGE• Field selectable to match power source of 12, 16, or
24 VAC/VDC.
CURRENT DRAW/AMPSVOLTS AC INTERMITTENT DC CONTINUOUS
12 0.163 0.440
16 0.228 0.458*
24 0.084 0.230
*Requires 16 DC adapter (P/N VA 7400-16VDC)
STANDARD PACKAGE• Individually boxed with mounting screws, mounting tabs,
adhesive shims to accommodate jamb or stile extrusion thickness greater or less than nominal 1/8", and adjustable jaw shim pack and two plug-in voltage adapters for 12/16/24 VAC and 12/24 VDC.
OPTIONS• Monitoring – Two internally mounted switches (Form “C") to
indicate when the latchbolt is engaged in the strike jaws and a locked/unlocked solenoid status.
• Lip Extension Kits – For various dimensions of door centerline to jamb edge.
• Modular Packaging – Consult factory or sales representative for details.
• 16 VDC Adapter – VA7400-16VDC required when using 16 VDC power.
ULTRALINE 7410, 7411 ELECTRIC STRIKES
7410 Electric Strike with 7-15/16" faceplate and 7411 Electric Strike with 10-1/4" faceplate are designed for Adams Rite deadlatches or cylindrical locksets with 1/2" to 5/8" latchbolt projection. For use in hollow metal, wood and aluminum door jambs. Opens electrically under 35 lbs. of preload.
FunctionReplaces earlier 7510, 7810 electric strikes in either metal or wood jambs for remote electrical control of any door equipped with an Adams Rite 4500, 4700, or 4900 Series (or similar) Deadlatch or cylindrical (key-in-knob/lever) type lockset with 1/2" to 5/8" latchbolt projection. Electrical actuation unlocks strike jaw, releasing latchbolt so door can be opened without operating latch itself. Extremely compact mechanism fits into jamb sections as shallow as 1-1/16". Direct upgrade for Adams Rite 7110 Electric Strikes.
This non-handed strike features an ultra-compact design and an adjustable stainless steel split-jaw with over 1500 lbs. of holding force in fail-secure mode. The strike releases electrically with up to 35 lbs. of door “preload" (pressure exerted on doors by air conditioning systems, warping or misaligned hardware which can disable common electric strikes). Single solenoid operates on 12, 16, or 24 volt AC/DC power. Strikes are equipped with a quick connect plug-in type connector.
ALUMINUM HOLLOWMETAL
WOOD UL BURGLARY
LISTED
ELECTRIFIED PRODUCT
GRADE 1 E09321
Using jaw inserts of various sizes, the Ultraline 7400 Series electric strikes are adjustable to compensate for door and frame related preload and security problems.
ELECTRIC STRIKES ES-19
800.872.3267 • Fax 800.232.7329
10027 S. 51st Street, Ste 102 Phoenix, Arizona 85044
www.adamsrite.comARM-014-9/14
JAMB
“A”
VERTICAL OF ELECTRIC STRIKE SAME AS VERTICAL
OF LATCH MOUNTING SCREWS
HORIZONTAL OF STRIKE
SAME AS HORIZONTAL OF LATCH BOLT
“A”
JAMB
12-24 COMBINATIONSCREW (2 REQD.)
STANDARD UNIT FITS DIM. “A” UP TO 1-1/16"ORDER LIP EXTENSION KITS REQUIRED
1-13/32"35.7mm
1-1/16"27mm21/32"
16.7mm
1-25/32"45.2mm
3/32"2.4mm
1-7/16"36.5mm
3-3/8"85.7mm
3-3/8"85.7mm
1-7/16"36.5mm
1-7/16"36.5mm
3/32"2.4mm
1-3/8"34.9mm
21/32"16.7mm
3-3/8"85.7mm
7410:7-7/16"188.9mm
7410:7-15/16"201.6mm
7411:9-29/64"240.1mm
7411:10-1/4"260.4mm
TURN STRIKE UPSIDE DOWN
FOR OPPOSITE HAND
7410:7-7/16"188.9mm
7410:7-15/16"201.6mm
7411:9-29/64"240.1mm
7411:10-1/4"260.4mm
R
(4 PLACES)
5/32"4mm
ULTRALINE 7410, 7411 ELECTRIC STRIKES
RELATED PRODUCTS When purchasing this product, please consider the following related products, available separately:
SpecificationsFAIL-SAFE/FAIL-SECURE• Field selectable at time of installation.
CASE• Approximately 1" x 3-3/8" x 1-1/16" deep.
STRIKE LIP• Basic 7400 electric strike has lip of proper length for 1-3/4"
thick door that closes flush with jamb edge. Where door thickness or jamb shape differs from this standard relationship, lip extension kits are available. Not available on 7431.
STRIKE OPENING• 5/8" adjustable x 1-7/16" x 1/2" deep. Bolt retainer jaw is
stainless steel. Strike accepts bolt of Adams Rite 4500, 4700 (discontinued), or 4900 Series Deadlatch or cylindrical latches.
FACEPLATE• Measures 1-1/4” x 6-7/8”. 7430 has flat faceplate; 7431
is radiused to match nose on inactive leaf in a pair of aluminum stile glass doors. Available in a wide range of architectural finishes.
VOLTAGE• Field selectable to match power source of 12, 16, or 24
VAC/VDC.
CURRENT DRAW/AMPSVOLTS AC INTERMITTENT DC CONTINUOUS
12 0.163 0.440
16 0.228 0.458*
24 0.084 0.230
*Requires 16 DC adapter (P/N VA 7400-16VDC)
STANDARD PACKAGE• Individually boxed with mounting screws, mounting tabs,
adhesive shims to accommodate jamb or stile extrusion thickness greater or less than nominal 1/8", an adjustable jaw shim pack and two plug-in voltage adapters for 12/16/24 VAC and 12/24 VDC.
OPTIONS• Monitoring – Two internally mounted switches (Form “C") to
indicate when the latchbolt is engaged in the strike jaws and a locked/unlocked solenoid status.
• Lip Extension Kits – For various dimensions of door centerline to jamb edge.
• Modular Packaging – Consult factory or sales representative for details.
• 16 VDC Adapter – VA7400-16VDC required when using 16 VDC power.
ULTRALINE 7430, 7431 ELECTRIC STRIKES
7430, 7431 Electric Strikes with 6-7/8" faceplates are designed for Adams Rite deadlatches or cylindrical locksets with 1/2" to 5/8" latchbolt projection. For use in aluminum jambs and stiles. Opens electrically under 35lbs. of preload.
FunctionRemote electrical control of any narrow stile or hollow metal door equipped with an Adams Rite 4500, 4700, or 4900 Series (or similar) Deadlatch or cylindrical (key-in-knob/lever) type lockset with 1/2" to 5/8" latchbolt projection. Large faceplate is designed to cover strike opening when converting from an MS® pivoted-bolt deadlock to a deadlatch. Electrical actuation unlocks strike jaw, releasing latchbolt so door can be opened without operating latch itself. Extremely compact mechanism fits into jamb sections as shallow as 1-1/16". Direct upgrade for Adams Rite 7130 Electric Strikes.
This non-handed strike features an ultra-compact design and an adjustable stainless steel split-jaw with over 1500 lbs. of holding force in fail-secure mode. The strike releases electrically with up to 35 lbs. of door “preload" (pressure exerted on doors by air conditioning systems, warping or misaligned hardware which can disable common electric strikes). Single solenoid operates on 12, 16, or 24 volt AC/DC power. Strikes are equipped with a quick connect plug-in type connector.
ALUMINUM HOLLOWMETAL
UL BURGLARY
LISTED
ELECTRIFIED PRODUCT
GRADE 1 E09321
Using jaw inserts of various sizes, the Ultraline 7400 Series electric strikes are adjustable to compensate for door and frame related preload and security problems.
ELECTRIC STRIKES ES-21
800.872.3267 • Fax 800.232.7329
10027 S. 51st Street, Ste 102 Phoenix, Arizona 85044
www.adamsrite.comARM-014-9/14
RADIUS FACE OF 7431
JAMB
PRESSURESENSITIVE
SPACER
MOUNTINGCLIP
PRESSEDMETAL NUT(2 REQD.)
JAMB
SEE DETAIL A
12-24 COMBINATIONSCREW (2 REQD.)
8-32 X 3/8FLAT HEAD
SCREW(2 REQD.)
“A”DRILL & CSK
FOR 8-32 FLAT HEAD SCREWS
(2 PLACES)
VERTICAL OF ELECTRIC STRIKE
FACEPLATE DIRECTLYOPPOSITE OF
DEADLATCH
HORIZONTAL OF ELECTRIC STRIKE
HORIZONTAL OF CYLINDER
(A-R 4500)SERIES DEADLATCH
1-13/32"35.7mm
1-1/16"27mm21/32"
16.7mm
1-11/16"42.9mm
3-3/8"85.7mm
3-3/8"85.7mm
3-3/8"85.7mm 8-1/8"
206.4mm
6-7/8"174.6mm
1-1/4"31.8mm
1-7/16"36.5mm
21/32"16.7mm
6-1/8"155.6mm
6-7/8"174.6mm
1-1/4"31.8mm
STANDARD UNIT FITS DIM. “A” 1-1/16"MOUNTING BACKSETS FURNISHED
“A”
3/32"2.4mm
TURN STRIKE UPSIDE DOWN
FOR OPPOSITE HAND
R
(4 PLACES)
5/32"4mm
ULTRALINE 7430, 7431 ELECTRIC STRIKES
RELATED PRODUCTS When purchasing this product, please consider the following related products, available separately:
SpecificationsFAIL-SAFE/FAIL-SECURE• Field selectable at time of installation.
CASE• Approximately 1" x 3-3/8" x 1-1/16" deep.
STRIKE LIP• Basic 7400 electric strike has lip of proper length for
1-3/4" thick door that closes flush with jamb edge. Where door thickness or jamb shape differs from this standard relationship, lip extension kits are available.
STRIKE OPENING• 5/8" adjustable x 1-7/16" x 1/2" deep. Bolt retainer jaw
is stainless steel. Strike accepts bolt of Adams Rite 4500, 4700 (discontinued), or 4900 Series Deadlatch or cylindrical latches.
FACEPLATE• Measures 1-1/4” x 4-7/8”. Faceplate is flat, with square
corners. Available in a wide range of architectural finishes.
VOLTAGE• Field selectable to match power source of 12, 16, or 24
VAC/VDC.
CURRENT DRAW/AMPSVOLTS AC INTERMITTENT DC CONTINUOUS
12 0.163 0.440
16 0.228 0.458*
24 0.084 0.230
*Requires 16 DC adapter (P/N VA 7400-16VDC)
STANDARD PACKAGE• Individually boxed with mounting screws, mounting tabs,
adhesive shims to accommodate jamb or stile extrusion thickness greater or less than nominal 1/8", and adjustable jaw shim pack and two plug-in voltage adapters for 12/16/24 VAC and 12/24 VDC.
OPTIONS• Monitoring – Two internally mounted switches (Form “C") to
indicate when the latchbolt is engaged in the strike jaws and a locked/unlocked solenoid status.
• Lip Extension Kits – For various dimensions of door centerline to jamb edge.
• Modular Packaging – Consult factory or sales representative for details.
• Wood Door Cover – WDC7400 for use when mounting the 7400 Series Electric Strike on the inactive leaf of a pair of door. The cover simplifies the mortise prep.
• 16 VDC Adapter – VA7400-16VDC required when using 16 VDC power.
ULTRALINE 7440 ELECTRIC STRIKES
FunctionRemote electrical control of any door equipped with an Adams Rite 4500, 4700, or 4900 Series (or similar) Deadlatch or cylindrical (key-in-knob/lever) type lockset with 1/2" to 5/8" latchbolt projection. Electrical actuation unlocks strike jaw, releasing latchbolt so door can be opened without operating latch itself. Extremely compact mechanism fits into jamb sections as shallow as 1-1/16". Direct upgrade for Adams Rite 7140 Electric Strikes.
This non-handed strike features an ultra-compact design and an adjustable stainless steel split-jaw with over 1500 lbs. of holding force in fail-secure mode. The strike releases electrically with up to 35 lbs. of door “preload" (pressure exerted on doors by air conditioning systems, warping or misaligned hardware which can disable common electric strikes). Single solenoid operates on 12, 16, or 24 volt AC/DC power. Strikes are equipped with a quick connect plug-in type connector.
WOOD HOLLOWMETAL
UL BURGLARY
LISTED
ELECTRIFIED PRODUCT
GRADE 1 E09321
7440 Electric Strikes with 4-7/8" faceplate are designed for Adams Rite deadlatches or cylindrical locksets with 1/2" to 5/8" latchbolt projection. For use in hollow metal or wood door jambs and steel or wood doors. Opens electrically under 35lbs. of preload.
Using jaw inserts of various sizes, the Ultraline 7400 Series electric strikes are adjustable to compensate for door and frame related preload and security problems.
ELECTRIC STRIKES ES-23
800.872.3267 • Fax 800.232.7329
10027 S. 51st Street, Ste 102 Phoenix, Arizona 85044
www.adamsrite.comARM-014-9/14
ULTRALINE 7440 ELECTRIC STRIKES
Dimensions
MOUNTING BRACKETWELDED TO JAMB
12-24 COMBINATIONSCREW (2 REQD.)
VERTICAL OF ELECTRIC
STRIKE FACEPLACEDIRECTLY OPPOSITE
OF DEADLATCH
HORIZONTAL OF CYLINDER
(A-R 4500 & 4700SERIES DEADLATCHES)
HORIZONTAL OF ELECTRIC STRIKE
PRESSURE SENSITIVE
SPACER
12-24(2 PLACES)
“A”
1-1/16"27mm
1-11/16"42.9mm
21/32"16.7mm
1-13/32"35.7mm
1-1/4"31.8mm
3/32"2.4mm
4-1/8"104.8mm
3-3/8"85.7mm 4-7/8"
123.8mm
JAMB
STANDARD UNIT FITS DIM. “A” UP TO 1-1/16"MOUNTING BRACKETS FURNISHED
“A”
3-3/8"85.7mm
JAMB
TURN STRIKE UPSIDE DOWN
FOR OPPOSITE HAND
MOUNTING BRACKET(MOUNTING CLIP)
WELDED TO JAMB OR PROVIDED
3-3/8"85.7mm
1-7/16"36.5mm
4-1/8"104.8mm
4-7/8"123.8mm
3-5/8"92.1mm
21/32"16.7mm
1-1/4"31.8mm
Jamb Preparation
Installation
HOW TO ORDER 7440 ELECTRIC STRIKE Specify quantity and the following information. Order related products separately.
PRODUCT NO. FEATURES FINISH
7440 M 628- None STANDARD FINISHES
M Monitored 313 Dark Bronze Anodized 612 Satin Bronze
335 Black Anodized 628 Clear Anodized
605 Bright Brass 629 Bright Stainless
606 Satin Brass 630 Satin Stainless
Fail-secure can be field converted to fail-safe or vice-versa.
RELATED PRODUCTS When purchasing this product, please consider the following related products, available separately:
Options Power Deadlatches
Lip extensions. WDC7400-Wood Door Cover. ELX-ElectroLynx™ Adapter. VA7400-16VDC Adapter.
• 16 VDC Adapter – VA7400-16VDC required when using 16 VDC power.
ULTRALINE 74R1 ELECTRIC STRIKE
FunctionA semi-mortised strike for rim exit devices having 3/4" Pullman type bolts without auxiliary bolts. Provides electrical remote control, allowing door to open without actuation of the exit device.
This non-handed strike features an ultra-compact design and a stainless steel split-jaw with over 1500 lbs. of holding force in fail-secure mode. The strike releases electrically with up to 35 lbs. of door “preload" (pressure exerted on doors by air conditioning systems, warping or misaligned hardware which can disable common electric strikes). Single solenoid operates on 12, 16, or 24 volt AC/DC power. Strikes are equipped with a quick connect plug-in type connector.
74R1 Electric Strike is designed for rim exit devices with 3/4" Pullman type latchbolt. For use in hollow metal, wood and aluminum door jambs. Opens electrically under 35lbs. of preload.
ALUMINUM HOLLOWMETAL
WOOD UL BURGLARY
LISTED
ELECTRIFIED PRODUCT
GRADE 1 E09321
ELECTRIC STRIKES ES-25
800.872.3267 • Fax 800.232.7329
10027 S. 51st Street, Ste 102 Phoenix, Arizona 85044
• 16 VDC Adapter – VA7400-16VDC required when using 16 VDC power.
ULTRALINE 74R2 ELECTRIC STRIKE
74R2 Electric Strike is designed for narrow stile rim exit devices with 1/2" Pullman type latchbolt. For use in aluminum door jambs. Opens electrically under 35lbs. of preload.
FunctionA semi-mortised strike for rim exit devices having 1/2" Pullman type bolts. Provides electrical remote control, allowing door to open without actuation of the exit device.
This non-handed strike features an ultra-compact design and a stainless steel split-jaw with over 1500 lbs. of holding force in fail-secure mode. The strike releases electrically with up to 35 lbs. of door “preload" (pressure exerted on doors by air conditioning systems, warping or misaligned hardware which can disable common electric strikes). Single solenoid operates on 12, 16, or 24 volt AC/DC power. Strikes are equipped with a quick connect plug-in type connector.
ALUMINUM UL BURGLARY
LISTED
ELECTRIFIED PRODUCT
GRADE 1 E09321
ELECTRIC STRIKES ES-27
800.872.3267 • Fax 800.232.7329
10027 S. 51st Street, Ste 102 Phoenix, Arizona 85044
Lip Extension Kits for 7100 Series Electric Strikes Lip extensions are for center hung doors, thick doors, or other conditions that vary from the “standard” 1-3/4" thick door that closes flush (or near flush) with the jamb face. Specified with electric strike by the last dash number which varies the door centerline to jamb edge dimension in 1/8” increments. For existing 7100 Series Electric Strikes, a thin metal membrane in the standard lip can be drilled or punched out and the lip extension can be added in the field. The dash number for lip extension is the same as door centerline to jamb edge dash number on complete strike.
7100 LIP EXTENSIONLIP EXTENSION PART NUMBER APPLICABLE ELECTRIC STRIKES
91-0171-01 through -13 7100, 7110, 7111, 7130, 7140
91-0172-01 through -13 7160, 7170
91-0173-01 through -13 7108, 7128
7100 LIP EXTENSION DIMENSIONS
DASH PART NUMBER
DIMENSION ‘A’ – DOOR CENTERLINE
TO JAMB EDGE
DASH PART NUMBER
DIMENSION ‘A’ – DOOR CENTERLINE
TO JAMB EDGE
-00 1-1/16” -07 2-1/4”
-01 1-1/2” -08 2-3/8”
-02 1-5/8” -09 2-1/2”
-03 1-3/4” -10 2-5/8”
-04 1-7/8” -11 2-3/4”
-05 2” -12 2-7/8”
-06 2-1/8” -13 3”
1-1/16" or less does not require a lip extension.
Lip extensions for fire-rated 7200 Series Electric Strikes must be factory installed.
Lip Extension Kits for Ultraline 7400 Series Electric Strikes Lip extensions are for center hung doors, thick doors, or other conditions that vary from the “standard” 1-3/4" thick door that closes flush (or near flush) with the jamb face. Lip extension kits are available in 1/8" increments.
7400 LIP EXTENSION
PART NUMBER DIMENSION ‘A’ – DOOR CENTERLINE TO JAMB EDGE
LEK7400-50 1-3/8"
LEK7400-01 1-1/2"
LEK7400-02 1-1/16"
LEK7400-03 1-3/4"
LEK7400-04 1-7/8"
LEK7400-05 2"
LEK7400-06 2-1/8"
LEK7400-07 2-1/4"
LEK7400-08 2-3/8"
LEK7400-09 2-1/2"
LEK7400-10 2-5/8"
LEK7400-11 2-3/4"
LEK7400-12 2-7/8"
LEK7400-13 3"
1-1/16" or less does not require a lip extension.
OPTIONS & ACCESSORIES FOR ELECTRIC STRIKES
LIP EXTENSION
EXTENSION
WDC7400*
7400 ASSEMBLY
JAMB
“A”
WDC7400
*THE SPACER IS DESIGNED TO
SIMPLIFY MORTISING ON WOOD DOOR APPLICATIONS
800.872.3267 • Fax 800.232.7329
10027 S. 51st Street, Ste 102 Phoenix, Arizona 85044
www.adamsrite.comARM-014-9/14
ELECTRIC STRIKES ES-29
Power 4603 RECTIFIER Converts low voltage AC current to DC of same voltage. Installs in low voltage line between transformer and strike. Full wave bridge type. Rated 2 amps (200 PIV).
29-0218 PIEZO HORN Provides for audible indication of when a DC strike is energized. Operates with 12 VDC, 16 VDC, or 24 VDC strikes.
TRANSFORMERS
4605Converts 120 VAC to 12/24 VAC. Rated 40 Volt-amp output assures plenty of power for strike release.
4606Converts 120 VAC current to 24 VAC. Plugs into standard wall outlet.
PS-1 POWER SUPPLYProvides filtered and regulated voltage output to power electric strikes, magnetic locks, or other access control devices. Output is selectable in the field for 12 or 24 VDC. Charging circuit is built-in for battery backup power with 12 or 24 VDC operation. LED on circuit board indicates power input.
WDC7400 Wood Door ApplicationFor use with Ultraline 7400 Electric Strikes only, this cover plate is designed to simplify mortising of wood door pairs.
Monitor SwitchesIf a visual or other signal is required to tell an operator what the electric strike is doing, a “monitoring” strike to switch that signal on and off is required.
This feature utilizes two sensor switches: one is activated by the latchbolt’s penetration of the strike and the other by the mechanism that blocks the strike’s release.
These switches can also be used to interconnect two strikes in “mantrap” or interlock situations, such as elevator doors. In these cases, power to the solenoid of each strike is controlled by the switch(es) of the other so one will not unlock unless the other is locked. Each switch has both normally open and normally closed leads to they can be wired to either make or break a circuit.
OPTIONS & ACCESSORIES FOR ELECTRIC STRIKES
4605 4606
115 VAC LINE
BLACK BLACKWHITE
LIGHT
COIL
NOCNOC
NCNC
WIRE LEADACTUATING
SWITCHWIRE LEAD
LIGHT
RED
STRIKE JAW LOCKED
BOLT SENSOR(DEPRESSED)
#4605 TRANSFORMER(40 VA OR EQUIVALENT 125 VA MINIMUM)#4603 RECTIFIER(REQUIRED FOR AC RECTIFIED SILENT OPERATION ONLY)