    SANtricityStorage Manager

    Command Line Interface andScript Commands

    Quick Reference for Version 9.25

    ES1790-0-E1, First Edition

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    2/62

    Proprietary Rights Notice

    This document contains proprietary information of LSI Logic Corporation. The information contained

    herein is not to be used by or disclosed to third parties without the express written permission of an officer of

    LSI Logic. Any products described herein are licensed products of LSI Logic.

    Document Description

    Document ES1790-0-E1, First Edition. July 2006

    This document will remain the official reference source for all revisions and releases of this product until

    rescinded by an update.

    Disclaimer

    It is the policy of LSI Logic Corporation to improve products as new technology, components, software, and

    firmware become available. LSI Logic reserves the right to make changes to any products herein at any time

    without notice. All features, functions, and operations described herein may not be marketed by LSI Logic

    in all parts of the world. In some instances, photographs and figures are of equipment prototypes. Therefore,

    before using this document, consult your LSI Logic representative for information that is applicable andcurrent. LSI LOGIC DOES NOT ASSUME ANY RESPONSIBILITY OR LIABILITY FOR THE USE OF

    ANY PRODUCTS DESCRIBED HEREIN EXCEPT AS EXPRESSLY AGREED TO IN WRITING BY

    LSI LOGIC.

    License Restriction

    The purchase or use of an LSI Logic Corporation product does not convey a license under any patent,

    copyright, trademark, or other intellectual property right of LSI Logic or third parties.

    Copyright Notice

    2006. LSI Logic Corporation. All rights reserved.

    Trademark Acknowledgments

    Engenio, the Engenio design, HotScale, SANtricity, and SANshare are trademarks or registered trademarks

    of LSI Logic Corporation. All other brand and product names may be trademarks of their respective

    companies.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    3/62

    SANtricityStorage Manager CLI Quick Reference for Version 9.25 i

    Contents

    COMMANDLINEINTERFACEANDSCRIPTCOMMANDSQUICKREFERENCE

    About the Command Line Interface............................................................................................ 2

    Command Line Interface Structure........................................................................................ 2

    Usage Notes ........................................................................................................................... 3

    CLI Commands ...................................................................................................................... 3

    CLI Command Formatting........................................................................................................ 12

    Usage Examples................................................................................................................... 13

    About the Script Commands ..................................................................................................... 14

    Script Command Structure................................................................................................... 14Recurring Syntax Elements.................................................................................................. 15

    Script Command Formatting..................................................................................................... 21

    Script Commands ...................................................................................................................... 23

    Commands Listed by Function ................................................................................................. 46

    Controller Commands .......................................................................................................... 46

    Host Topology Commands .................................................................................................. 46

    Module Commands .............................................................................................................. 47

    Physical Disk (Drive) Commands........................................................................................ 47Remote Volume Mirroring Commands ............................................................................... 47

    Session Command................................................................................................................ 48

    Snapshot Commands............................................................................................................ 48

    Storage Array Commands.................................................................................................... 48

    Uncategorized Command..................................................................................................... 49

    Volume Commands.............................................................................................................. 50

    Volume Copy Commands.................................................................................................... 50

    Volume Group Commands .................................................................................................. 51

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    4/62

    ii SANtricityStorage Manager CLI Quick Reference for Version 9.25

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    5/62

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    6/62

    iv SANtricityStorage Manager CLI Quick Reference for Version 9.25

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    7/62

    SANtricityStorage Manager CLI Quick Reference for Version 9.25 v

    Document Conventions

    Definitions of Safety Notices

    DANGER Indicates an imminently hazardous situation that will result in death or

    severe personal injury.

    WARNING Indicates a potentially hazardous situation that could result in death or

    severe personal injury.

    CAUTION Indicates a potentially hazardous situation that could result in moderate or

    minor personal injury.

    Definitions of Informational Notices

    CAUTION Indicates a potentially hazardous situation that could result in data loss (or

    other interruption) or equipment damage.

    IMPORTANT Indicates information or criteria that is necessary to perform a procedure

    correctly.

    NOTE Indicates a clarification of a concept or presents a maintenance tip.

    Typographic Conventions

    Italicindicates the title of documents, variables and placeholders in text, emphasized

    words, and new terms.

    Boldindicates choices in procedures and other emphasized text.

    Monospaceindicates arguments, code examples, command-line text, command options,commands, directories, error messages, file names, folders, on-screen text, and user input.

    Monospace italicindicates command variables in code, parameters, and

    placeholders and variables in code.

    Monospace boldindicates keywords and values.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    8/62

    vi SANtricityStorage Manager CLI Quick Reference for Version 9.25

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    9/62

    SANtricityStorage Manager CLI Quick Reference for Version 9.25 vii

    About This Document

    This document is a quick reference that lists the command line interface commands and

    the script commands for the SANtricity Storage Manager Version 9.25 software. This

    document provides the following information:

    A brief overview of the command line interface and script commands

    The command line interface commands

    The script commands

    The command syntax

    A brief description of the purpose of each script command

    This document assumes that the user has a knowledge of basic storage area network

    (SAN) hardware and installation skills. Read the Storage System Product Release Notes

    for Version 9.25for any updated information regarding hardware, software, or firmwareproducts that might not be described in this document.

    Intended Readers

    This document is intended for system operators, system administrators, and service

    personnel who are responsible for operating, maintaining, troubleshooting, and servicing a

    storage array. Users must be familiar with computer system operation, maintenance, andrepair. In addition, they should understand disk array, Redundant Array of Independent

    Disks (RAID) concepts, network, and Fibre Channel technologies. The reader must have a

    basic knowledge of SAN hardware functionality (controllers, drives, hosts) and SAN

    cabling.

    Related Publications

    SANtricity Storage Manager Command Line Interface and Script Commands

    Programming Guide for Version 9.25

    Storage System Product Release Notes for Version 9.25

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    10/62

    viii SANtricityStorage Manager CLI Quick Reference for Version 9.25

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    11/62

    SANtricityStorage Manager CLI Quick Reference for Version 9.25 1

    Command Line Interface and ScriptCommands Quick Reference

    The command line interface and script commands provide a tool set that enables users to

    configure and maintain a storage array directly from the command line in the operating

    system. This quick reference provides:

    A brief description of the command line interface

    A list of the commands and parameters for the command line interface (CLI)

    An overview of the script commands

    An explanation of the command formatting

    A table that alphabetically lists the script commands and briefly describes the

    purpose of each command

    A functional list of the commands, in which the commands are organized by

    operational utility in the storage array

    This quick reference helps you find the correct syntax and parameters for the commands

    that you are using. It is not intended to be a complete programming guide. This quickreference is for users who have read and understood the information in the SANtricity

    Storage Manager Command Line Interface and Script Commands Programming Guide. If

    you have questions related to the commands or parameters listed in this quick reference,

    refer to the programming guide for additional information.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    12/62

    Command Line Interface and Script Commands Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . .

    2 SANtricityStorage Manager CLI Quick Reference for Version 9.25

    About the Command Line Interface

    The command line interface is a software tool that enables storage array installers,

    developers, and engineers to configure and monitor storage arrays. Using the command

    line interface, you can issue commands from an operating system prompt, such as theDOS C:\prompt, a Linux operating system path, or a Solaris operating system path. Eachcommand performs a specific action for managing a storage array or returning information

    about the status of a storage array. You can enter individual commands or you can run

    script files when you need to perform operations more than once (such as installing the

    same configuration on several storage arrays). The command line interface enables you to

    load a script file from a disk and run the script file. The command line interface provides a

    way to run storage management commands on more than one network storage array. You

    can use the command line interface in both installation sites and development

    environments.

    Command Line Interface StructureThe commands you run on the CLI provide access to the script engine, specify the storage

    array to receive the script commands, and set operation environment parameters.

    A CLI command consists of the following elements:

    The term SMcli

    The storage array identifier

    The parameters

    The script commands

    The general form of a CLI command is:

    SMcli storageArrayparametersscript-commands;

    where:

    SMcliinvokes the command line interface

    storageArrayis the name or the IP address of the storage array

    parametersare CLI parameters that define the environment and purpose for the

    command

    script-commandsis one or more script commands or the name of a script filecontaining script commands. (The script commands are the storage array

    configuration commands.)

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    13/62

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . About the Command Line Interface

    SANtricityStorage Manager CLI Quick Reference for Version 9.25 3

    Usage Notes

    If you enter SMcliand a storage array name, but do not specify CLI parameters, scriptcommands, or a script file, the command line interface runs in interactive mode.

    Interactive mode enables you to run individual commands without prefixing the

    commands with SMcli. In interactive mode, you can enter a single command, view theresults, and enter the next command without typing the complete SMclistring.Interactive mode is useful for determining configuration errors and quickly testing

    configuration changes.

    If you enter SMcliwithout any parameters or with an incorrect parameter, the scriptengine returns usage information.

    CLI Commands

    This section lists the CLI commands that you can use to perform the following actions:

    Identify storage arrays

    Specify passwords

    Add storage arrays to configuration files

    Specify communications parameters

    Enter individual script configuration commands

    Specify a file containing script configuration commands

    Table 1 lists the conventions used in the general form of a CLI command.

    Table 1 Command Name Conventions

    Convention Definition

    a | b Alternative (a or b)

    italicized-words Terminals

    [...](square brackets) Zero or one occurrence(Square brackets are also used as a

    delimiter for some command

    parameters.)

    {...}(curly braces) Zero or more occurrences

    (a | b | c) Choose only one of the alternatives

    bold Terminals

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    14/62

    Command Line Interface and Script Commands Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . .

    4 SANtricityStorage Manager CLI Quick Reference for Version 9.25

    The following are general forms of the CLI commands, showing the parameters and

    terminals used in each command. Table 2 on page 5lists definitions for the parameters

    shown in the general form of the CLI commands.

    SMclihost-name-or-IP-address [host-name-or-IP-address]

    [-c command; {command2};][-nstorage-array-name| -wWWN][-ooutputfile][-ppassword][-e][-S][-quick]

    SMclihost-name-or-IP-address [host-name-or-IP-address][-fscriptfile][-nstorage-array-name| -wWWN][-ooutputfile][-ppassword][-e][-S][-quick]

    SMcli(-nstorage-array-name| -wWWN)[-c command; {command2};][-ooutputfile][-ppassword][-e][-S][-quick]

    SMcli(-nstorage-array-name| -wWWN)[-fscriptfile][-ooutputfile][-ppassword][-e][-S][-quick]

    SMcli-aemail:email-address[host-name-or-IP-address1[host-name-or-IP-address2]][-nstorage-array-name| -wWWN| -hhost-name|-r (host_sa| direct_sa)][-Iinformation-to-include][-qfrequency][-S]

    SMcli-xemail:email-address[host-name-or-IP-address1[host-name-or-IP-address2]]

    [-nstorage-array-name| -wWWN| -hhost-name|-r (host_sa| direct_sa)] [-S]

    SMcli(-a| -x) trap:community, host-name-or-IP-address[host-name-or-IP-address1[host-name-or-IP-address2]][-nstorage-array-name| -wWWN| -hhost-name|-r (host_sa| direct_sa)] [-S]

    SMcli-d [-w][-i][-s][-v][-S]

    SMcli-mhost-name-or-IP-address-Femail-address[-gcontactInfoFile][-S]

    SMcli-A[host-name-or-IP-address[host-name-or-IP-address]][-S]

    SMcli-X (-nstorage-array-name| -wWWN| -hhost-name)

    SMcli-?

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    15/62

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . About the Command Line Interface

    SANtricityStorage Manager CLI Quick Reference for Version 9.25 5

    Table 2 Command Line Parameters

    Parameter Definition

    host-name-or-IP-address You can specify either the host name or the Internet Protocol (IP)address (xxx.xxx.xxx.xxx) of an in-band managed storage array or

    an out-of-band managed storage array.

    If you are managing a storage array using a host through

    in-band storage management, you must use the -nor -wparameter if more than one storage array is connected to the

    host.

    If you are managing a storage array using out-of-band storage

    management through the Ethernet connection on each

    controller, you must specify the host-name-or-IP-address of

    the controllers.

    If you have previously configured a storage array in theEnterprise Management Window (EMW), you can specify

    the storage array by its user-supplied name using the -nparameter.

    If you have previously configured a storage array in the

    EMW, you can specify the storage array by its World Wide

    Name using the -wparameter.

    -A Use this parameter to add a storage array to the configuration files.If you do not follow the -Aparameter with ahost-name-or-IP-address, auto-discovery scans the local subnet

    for storage arrays.

    -a Use this parameter to add a Simple Network Management Protocol(SNMP) trap destination or an email address alert destination.

    When adding an SNMP trap destination, the SNMP

    community is automatically defined as the community name

    for the trap and the hostis the IP address or Domain Name

    Server (DNS) host name of the system to which the trap

    should be sent.

    When adding an email address for an alert destination, the

    email-addressis the email address where you want the alert

    message to be sent.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    16/62

    Command Line Interface and Script Commands Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . .

    6 SANtricityStorage Manager CLI Quick Reference for Version 9.25

    -c Use this parameter to indicate that you are entering one or morescript commands to run on the specified storage array. Terminate

    each command by a semicolon (;).

    You cannot place more than one -cparameter on the samecommand line. You can include more than one script command

    after the -cparameter.

    -d Use this parameter to display the contents of the scriptconfiguration file. The format of the file contents is:

    storage-Array-name host-name1 host-name-2

    -e Use this parameter to run the commands without performing asyntax check first.

    -F(uppercase) Use this parameter to specify the email address from which allalerts will be sent.

    -f Use this parameter to specify a file name containing scriptcommands that you want to run on the specified storage array.

    (This parameter is similar to the -cparameter in that both areintended for running script commands. The -cparameter runsindividual script commands. The -fparameter runs a file of scriptcommands.)

    By default, any errors encountered when running the script

    commands in a file are ignored, and the file continues to run. Tooverride this behavior, use the set sessionerrorAction=stopcommand in the script file.

    -g Use this parameter to specify an ASCII file containing emailsender contact information that will be included in all email alert

    notifications. The CLI assumes the ASCII file is text only, without

    delimiters or any expected format. Do not use this parameter if a

    userdata.txtfile exists.

    -h Use this parameter to specify the host name that is running theSNMP agent to which the storage array is connected. Use this

    parameter with the -aand -xparameters.

    Parameter Definition

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    17/62

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . About the Command Line Interface

    SANtricityStorage Manager CLI Quick Reference for Version 9.25 7

    -I Use this parameter to specify the type of information to beincluded in the email alert notifications. Valid information

    arguments are:

    eventOnly

    profile

    supportBundle

    -i Use this parameter to display the IP address of the known storagearrays. Use this parameter with the -dparameter. The format ofthe file contents is:

    storage-Array-name IP-address-1 IP-address-2

    -m Use this parameter to specify the host name or IP address of the

    email server from which email alert notifications will be sent.

    -n Use this parameter to specify the name of the storage array onwhich you want to run the script commands. This name is optional

    when you use a host-name-or-IP-address; however, if you are

    using the in-band method for managing the storage array, you must

    use the -nparameter if more than one storage array is connected tothe host at the specified address.

    The storage array name is required when the

    host-name-or-IP-addressis not used; however, the name of the

    storage array configured for use in the Enterprise Management

    Window (EMW) (that is, listed in the configuration file) must notbe a duplicate name of any other configured storage array.

    -o Use this parameter with the -cor -fparameter to specify a filename for all output text that is a result of running the script

    commands. If you do not specify an output file, the output text

    goes to stdout. All output from commands that are not script

    commands is sent to stdout, regardless of whether this parameter is

    set.

    -p Use this parameter to specify the password for the storage array onwhich you want to run commands. A password is not necessary

    under the following conditions:

    1. A password has not been set on the storage array.

    2. The password is specified in a script file you are running.

    3. You specify the password using the -cparameter and theset session password=passwordcommand.

    Parameter Definition

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    18/62

    Command Line Interface and Script Commands Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . .

    8 SANtricityStorage Manager CLI Quick Reference for Version 9.25

    -q Use this parameter to specify how frequently you want to includeadditional profile or support bundle information in the email alert

    notifications. An email alert notification containing at least thebasic event information is always generated for every critical

    event. If you set the -Iparameter to eventOnly, the only validargument for -qis everyEvent. If you set the -Iparameter toeitherprofileor supportBundle, this information is

    included with the emails with the frequency specified by the -qparameter.

    Valid frequency arguments are:

    everyEvent Information is returned with every email

    alert notification

    2 Information is returned no more than once every twohours

    4 Information is returned no more than once every four

    hours

    8 Information is returned no more than once every eight

    hours

    12 Information is returned no more than once every 12

    hours

    24 Information is returned no more than once every 24

    hours

    -quick Use this parameter to reduce the amount of time that is required to

    run a single-line operation. (An example of a single-line operationis the recreate snapshot volumecommand. Thisparameter reduces time by not running background processes for

    the duration of the command.

    Do not use this parameter for operations involving more than one

    single-line operation. Extensive use of this command can overrun

    the controller with more commands than the controller can

    process, which causes operational failure. Also, status and

    configuration updates normally collected from background

    processes will not be available to the CLI. This parameter causes

    operations that depend on background information to fail.

    -r Use this parameter with the -aor -xparameter to specify thename of an organizer node. The name of an organizer node can be

    either direct_sa(out-of-band storage array organizer node) or

    host_sa(in-band storage arrays organizer node [host-agent]). The

    -rparameter enables you to set or change the alert notificationsfor all storage arrays under each organizer node.

    Parameter Definition

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    19/62

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . About the Command Line Interface

    SANtricityStorage Manager CLI Quick Reference for Version 9.25 9

    -S(uppercase) Use this parameter to suppress informational messages describingcommand progress that appear when running script commands.

    (Suppressing informational messages is also called silent mode.)This parameter suppresses the following messages:

    Performance syntax check

    Syntax check complete

    Executing script

    Script execution complete

    SMcli completed successfully

    -s(lowercase) Use this parameter with the -dparameter to display the alertsettings in the configuration file.

    -v Use this parameter with the -dparameter to display the current

    global status of the known devices in a configuration file.

    -w Use this parameter to specify the WWN of the storage array. Thisparameter is an alternate to the -nparameter. Use the -wparameter with the -dparameter to display the WWNs of theknown storage arrays. The format of the file content is:

    storage-array-name world-wide-name

    IP-address-1 IP-address-2

    -X(uppercase) Use this parameter to delete a storage array from a configuration.

    -x( lowercase) Use this parameter to remove an SNMP trap destination or anemail address alert destination. The communityis the SNMP

    community name for the trap, and the hostis the IP address or

    DNS host name of the system to which you want the trap sent.

    -? Use this parameter to display usage information about the CLIcommands.

    Parameter Definition

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    20/62

    Command Line Interface and Script Commands Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . .

    10 SANtricityStorage Manager CLI Quick Reference for Version 9.25

    Exit Status

    After you run a CLI command, status is displayed that indicates the success of the

    operation that is defined by the command. The statuses are shown in Table 3 .

    Table 3 Exit Status

    Status

    ValueMeaning

    0 The command terminated without an error.

    1 The command terminated with an error. Information about the

    error is also displayed.

    2 The script file does not exist.

    3 An error occurred while opening an output file.

    4 A storage array is not at the specified address

    5 Addresses specify different storage arrays.

    6 A storage array name does not exist for the host agent connected.

    7 The storage array name was not at the specified address.

    8 The storage array name was not in the configuration file.

    10 A management class does not exists for the storage array.

    11 A storage array was not found in the configuration file.

    12 An internal error occurred.

    13 Invalid script syntax was found.

    14 The RAID controller module was unable to communicate with the

    storage array.

    15 A duplicate argument was entered.

    16 An execution error occurred.

    17 A host was not at the specified address.

    18 The WWID was not in the configuration file.19 The WWID was not at the address.

    20 An unknown IP address was specified.

    21 The event monitor configuration file was corrupted.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    21/62

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . About the Command Line Interface

    SANtricityStorage Manager CLI Quick Reference for Version 9.25 11

    22 The storage array was unable to communicate with the event

    monitor.

    23 The RAID controller module was unable to write alert settings.

    24 The wrong organizer node was specified.

    25 The command was not available.

    26 The device was not in the configuration file.

    27 An error occurred while updating the configuration file.

    28 An unknown host error occurred.

    29 The sender contact information file was not found.

    30 The sender contact information file could not be read.

    31 The userdata.txt file exists.

    32 An invalid -Ivalue in the email alert notification was specified.

    33 An invalid -fvalue in the email alert notification was specified.

    Status

    ValueMeaning

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    22/62

    Command Line Interface and Script Commands Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . .

    12 SANtricityStorage Manager CLI Quick Reference for Version 9.25

    CLI Command Formatting

    Double quotation marks ( ) used as part of a name or label require special consideration

    when you run the CLI and script commands on a Microsoft Windows operating system.

    The following bullet items explain how to use double quotation marks in names whilerunning CLI and script commands on a Windows operating system.

    When double quotation marks ( ) are part of a name or argument, you must insert a

    backslash (\) before each double quotation mark character. For example:

    -c set storageArray userLabel=\Engineering\;

    where Engineering is the storage array name. A second example is:

    -n \My\_Array

    where My_Array is the name of the storage array.

    You cannot use double quotation marks ( ) as part of a character string (also calledstring literal) within a script command. For example, you cannot enter the following

    string to set the storage array name to Finance Array:

    -c set storageArray userLabel=\\Finance\Array\;

    In the UNIX and Solaris operating systems, the delimiters around names or labels are

    single quotation marks ( ). The UNIX versions of the previous examples are:

    -c set storageArray userLabel=Engineering;

    -n My_Array

    In a Windows operating system, if you do not use double quotation marks ( ) around aname, you must insert a caret (^) before each special script character. Special characters

    are ^, |, .

    Insert a caret before each special script character when used with the -n, -o, -f,and -pparameters. For example, to specify storage array CLI>CLIENT, enter thefollowing string:

    -n CLI^>CLIENT

    Insert one caret (^) before each special script character when used within a script

    command string literal. For example, to change the name of a storage array to

    FINANCE_|_PAYROLL, enter the following string:

    -c set storageArray userLabel=\FINANCE_^|_PAYROLL\;

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    23/62

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CLI Command Formatting

    SANtricityStorage Manager CLI Quick Reference for Version 9.25 13

    Usage Examples

    The following examples show how to enter CLI commands on a command line. The

    examples show the syntax, form, and, in some examples, script commands. Examples are

    shown for both Windows and UNIX systems. Note that the usage for the -cparametervaries depending on your operating system. On Windows operating systems, enclose the

    script command following the -cparameter in double quotation marks ( ). On UNIXoperating systems, enclose the script command following the -cparameter in singlequotation marks ( ).

    This example shows how to delete an existing volume and create a new volume on a

    storage array. The existing volume name is Stocks_

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    24/62

    Command Line Interface and Script Commands Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . .

    14 SANtricityStorage Manager CLI Quick Reference for Version 9.25

    About the Script Commands

    You can use the script commands to configure and manage a storage array. The script

    commands are distinct from the CLI commands; however, you enter the script commands

    using the command line interface. You can enter individual script commands, or you canrun a file of script commands. When you enter an individual script command, you include

    it as part of a CLI command. When you run a file of script commands, you include the file

    name as part of a CLI command. The script commands are processed by a script engine

    that performs the following functions:

    Verifies command syntax

    Interprets the commands

    Converts the commands to the appropriate protocol-compliant commands

    Passes the commands to the storage array

    At the storage array, the script commands are run by the storage array controllers.

    Script Command Structure

    All script commands have the following structure:

    commandoperand-data{statement-data}

    where:

    commandidentifies the action to be performed

    operand-datarepresents the objects associated with a storage array that you want toconfigure or manage

    statement-dataprovides the information needed to perform the command

    The syntax for operand-datais:

    (object-type| allobject-types| [qualifier] (object-type[identifier] {object-type identifier]} | object-types[identifier-list]))

    You can identify an object in four ways:

    Object type Use an object type when the command is not referencing a specific

    object

    allparameter All objects of the specified type in the storage array (for example,

    allVolumes)

    Square brackets ([ ]) Use square brackets to identify a specific object on which to

    perform the command (for example, volume[engineering])

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    25/62

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .About the Script Commands

    SANtricityStorage Manager CLI Quick Reference for Version 9.25 15

    List of identifiers A subset of objects in square brackets (for example,

    volumes[sales engineering marketing])

    A qualifier is necessary if you want to include additional information to describe the

    objects. Table 4lists the object type and identifiers associated with the object types.

    Table 4 Object Types and Identifiers

    Statement data is in the form of attribute=value(raidLevel=5), an attribute name

    (batteryInstallDate), or an operation name(redundancyCheck).

    Recurring Syntax Elements

    Recurring syntax elements are a general category of variables and parameters you can use

    in one or more script commands. Table 5 on page 16lists the recurring syntax and thevalues that you can use with the syntax. The conventions listed in Table 1 on page 3define

    the meaning of the syntax values.

    Object Type Identifier

    controller a or b

    drive Tray ID and slot ID

    drivechannel Drive channel identifier

    host User label

    hostchannel Host channel identifierhostgroup User label

    hostport User label

    remote mirror Primary volume user label

    snapshot Volume user label

    storagearray Not applicable

    tray Tray ID

    volume Volume user label or volume World Wide Name (WWN) (set

    command only)

    volumecopy Target volume and, optionally, the source volume user labels

    volumegroup Volume group number

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    26/62

    Command Line Interface and Script Commands Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . .

    16 SANtricityStorage Manager CLI Quick Reference for Version 9.25

    Table 5 Recurring Syntax Elements

    Recurring Syntax Syntax Value

    raid-level (0 | 1 | 3 | 5)

    repository-raid-level (1 | 3 | 5)

    capacity-spec integer-literal [KB | MB | GB | TB | Bytes]

    segment-size-spec integer-literal

    boolean (TRUE | FALSE)

    user-label string-literal

    user-label-list user-label {user-label}

    create-raid-vol-attr-value-list create-raid-volume-attribute-value-pair

    {create-raid-volume-attribute-value-pair}

    create-raid-volume-attribute-value-pair capacity=capacity-spec|

    owner=(a | b) |

    readAheadMultiplier=integer-literal|

    segmentSize=integer-literal

    trayId (099)

    slot-id (132)

    port-id (0127)

    drive-spec trayID, slotIDdrive-spec-list drive-spec{drive-spec}

    tray-id-list trayID{trayID}

    hex-literal 0xhexadecimal-literal

    volume-group-number integer-literal

    filename string-literal

    error-action (stop | continue)

    drive-channel-identifier (1 | 2 | 3 | 4)

    drive-channel-identifier-list drive-channel-identifier{drive-channel-identifier}

    host-channel-identifier

    (all command modules except E6000)

    (a1 | a2 | b1 | b2)

    host-channel-identifier

    (E6000 command module only)

    (a1 | a2 | a3 | a4)

    (b1 | b2 | b3 | b4)

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    27/62

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .About the Script Commands

    SANtricityStorage Manager CLI Quick Reference for Version 9.25 17

    drive-type (fibre | SATA | PATA)

    feature-identifier (storagePartition2 | storagePartition4 |

    storagePartition8 | storagePartition16 |

    storagePartition64 | storagePartitionMax |

    snapshot | remoteMirror | volumeCopy)

    repository-spec instance-based-repository-spec |

    count-based-repository-spec

    instance-based-repository-spec repositoryRAIDLevel=repository-raid-level

    repositoryDrives=(drive-spec-list)

    [trayLossProtect=boolean1]

    repositoryVolumeGroup=volume-group-number

    [freeCapacityArea=integer-literal2]

    Specify repositoryRAIDLevelwith

    repositoryDrives. Do not specify RAID level or

    drives with volume group. Do not set

    trayLossProtectwhen specifying a volume group.

    count-based-repository-spec repositoryRAIDLevel=repository-raid-level

    repositoryDriveCount=integer-literal

    [driveType= drive-type3]

    [trayLossProtect=boolean4]

    WWN string-literal

    nvsram-offset hex-literal

    host-type string-literal | integer literal

    nvsram-byte-setting nvsram-value->0xhexadecimal | integer-literal

    nvsram-bit-setting nvsram-mask, nvsram-value->0xhexadecimal,

    0xhexadecimal | integer-literal

    ip-address (0255).(0255).(0255).(0255)

    autoconfigure-vols-attr-value-list autoconfigure-vols-attr-value-pair

    {autoconfigure-vols-attr-value-pair}

    Recurring Syntax Syntax Value

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    28/62

    Command Line Interface and Script Commands Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . .

    18 SANtricityStorage Manager CLI Quick Reference for Version 9.25

    1For tray loss protection to work, each physical disk in a volume group must be on a separatemodule. If you set trayLossProtect=TRUEand have selected more than one physical disk

    from any one module, the storage arrayreturns an error. If you settrayLossProtect=FALSE, the storage arrayperforms operations, but the volume group youcreate might not have tray loss protection.

    2To determine if a free capacity area exists, issue the show volumeGroupcommand.

    3The default physical disk (drive type) is fibre (Fibre Channel).

    4If you set trayLossProtect=TRUE, the storage arrayreturns an error if the controllerfirmware cannot find drives that will enable the new volume group to have tray loss protection. Ifyou set trayLossProtect=FALSE, the storage arrayperforms the operation even if it meansthat the volume group might not have tray loss protection.

    5The driveTypeparameter is not required if only one type of physical disk is in the storage

    array. If you use the driveTypeparameter, you must also use the hotSpareCountandvolumeGroupWidthparameters. If you do not use the driveTypeparameter, theconfiguration defaults to Fibre Channel physical disks.

    6volumesPerGroupCountis the number of equal capacity volumes per volume group.

    autoconfigure-vols-attr-value-pair driveType=drive-type5|

    raidLevel=raid-level|

    volumeGroupWidth=integer-literal|volumeGroupCount=integer-literal|

    volumesPerGroupCount=integer-literal6|

    hotSpareCount=integer-literal|

    segmentSize=segment-size-spec|

    readAheadMultiplier=integer-literal

    create-volume-copy-attr-value-list create-volume-copy-attr-value-pair

    {create-volume-copy-attr-value-pair}

    create-volume-copy-attr-value-pair copyPriority=(highest | high | medium | low |

    lowest)|

    targetReadOnlyEnabled=boolean

    recover-raid-volume-attr-value-list recover-raid-volume-attr-value-pair

    {recover-raid-volume-attr-value-pair}

    recover-raid-volume-attr-value-pair owner=(a | b)|

    readAheadMultiplier=integer-literal

    cache-flush-modifier-setting immediate, 0, .25, .5, .75, 1, 1.5, 2, 5, 10, 20, 60,

    120, 300, 1200, 3600, infinite

    Recurring Syntax Syntax Value

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    29/62

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .About the Script Commands

    SANtricityStorage Manager CLI Quick Reference for Version 9.25 19

    Usage Notes

    The following list provides guidelines for writing script commands on the command line:

    You must end all commands with a semicolon (;).

    You can enter more than one command on a line, but you must separate each

    command with a semicolon (;).

    You must separate each base command and its associated primary and secondary

    parameters with a space.

    The script engine is not case sensitive. You can enter commands using uppercase,

    lowercase, or mixed-case letters.

    Add comments to your scripts to make it easier for you and future users to

    understand the purpose of the script commands. For information on how to add

    comments, see Adding Comments to a Script File on page 20.

    NOTE: While the CLI and script commands are not case sensitive, user labels (such

    as for volume, hosts, or host ports) are case sensitive. If you try to map to an

    object identified by a user label, you must enter the user label exactly as it is

    defined, or the CLI and script commands will fail.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    30/62

    Command Line Interface and Script Commands Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . .

    20 SANtricityStorage Manager CLI Quick Reference for Version 9.25

    Adding Comments to a Script File

    You can add comments to a script file in three ways.

    The script engine interprets as a comment any text typed after two forward slashes (/

    /) until an end-of-line character is reached. If the script engine does not find an

    end-of-line character in the script after processing a comment, an error message is

    displayed, and the script operation is terminated. This error commonly occurs when

    a comment is placed at the end of a script and you have forgotten to press the Enter

    key.

    // Deletes the existing configuration.set storageArray resetConfiguration=true;

    The script engine interprets any text typed between/ *and * /as a comment. If the

    script engine does not find both a beginning and ending comment notation, an error

    message is displayed, and the script operation is terminated.

    /* Deletes the existing configuration */set storageArray resetConfiguration=true;

    Use the showstatement to embed comments in a script file that you want to displaywhile the script file is running. Enclose the text you want to display by using double

    quotation marks ( ).

    show Deletes the existing configuration;set storageArray resetConfiguration=true;

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    31/62

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Script Command Formatting

    SANtricityStorage Manager CLI Quick Reference for Version 9.25 21

    Script Command Formatting

    This section describes the general rules for formatting a script command and how the

    command syntax is presented in the following command descriptions. Syntax unique to a

    specific command is explained in the Notes section at the end of each commanddescription.

    The script commands are not case sensitive. You can type the commands in

    lowercase, uppercase, or mixed-case letters. (In the following command

    descriptions, mixed-case letters are used as an aid to reading the command names

    and understanding the purpose of the command.)

    You must enter spaces in the commands as they are shown in the command

    descriptions.

    Square brackets are used in two ways:

    As part of the command syntax

    To indicate the parameters are optional

    The description of each parameter tells you if you need to enclose a parameter value

    in square brackets.

    Parentheses shown in the command syntax enclose specific choices for a parameter;

    that is, if you want to use the parameter, you must enter one of the values enclosed in

    parentheses. Generally, you do not include parentheses in a command; however, in

    some instances, when you enter lists, you must enclose the list in parentheses. Such a

    list might be a list of tray ID values and slot ID values. The description of each

    parameter tells you if you need to enclose a parameter value in parentheses.

    Vertical bars in a command indicate or and separate the valid entries for the

    parameter. For example, the syntax for the raidLevelparameter in the commanddescription appears as:

    raidLevel=(0 | 1 | 3 | 5)

    To use the raidLevelparameter to set a RAID level of 5, enter:

    raidLevel=5

    When you specify physical disk locations using tray ID and slot ID values, separate

    the ID values by a comma. If you are entering more than one set of ID values,

    separate each set of values by a space. Enclose the set of values in parentheses. For

    example:

    (1,1 1,2 1,3 1,4 2,1 2,2 2,3 2,4)

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    32/62

    Command Line Interface and Script Commands Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . .

    22 SANtricityStorage Manager CLI Quick Reference for Version 9.25

    Italic terms in the command indicate a value or information that you need to provide.

    For example, when you encounter the italicized term:

    numberOfDrives

    replace the italicized term with a value for the number of physical disks you want toinclude with the command.

    You can use any combination of alphanumeric characters, hyphens (-), and

    underscores (_) for the names of the following components:

    Storage arrays

    Host groups

    Hosts

    Volume groups

    Volumes

    Host ports

    Names can have a maximum of 30 characters. If the label contains more than one

    word, underscores, or hyphens, enclose the name in double quotation marks. In some

    usages, you must also surround the name with square brackets. The description of

    each parameter indicates whether you need to enclose a parameter in double

    quotation marks or square brackets. The character string cannot contain a new line.

    You must use unique names; if you do not use unique names, the controller firmware

    returns an error.

    On Windows operating systems, the name must be enclosed between two

    backslashes (\) in addition to other delimiters. For example, the following name isused in a command running under a Windows operating system:

    [\Engineering\]

    For a UNIX system, and when used in a script file, the name appears as:

    [Engineering]

    When you enter a World Wide Name (WWN) of a host port, some usage requires

    you to surround the WWN with double quotation marks. In other uses, you must

    surround the WWN with angle brackets (< >). The description of the WWN

    parameter indicates whether you need to enclose the WWN in double quotation

    marks or angle brackets.

    Script commands must end with a semicolon (;). You can enter more than one script

    command on the command line each time you enter a CLI command.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    33/62

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Script Commands

    SANtricityStorage Manager CLI Quick Reference for Version 9.25 23

    Script Commands

    Table 6 Script Commands

    activate

    activate storageArray feature=remoteMirrorrepositoryRAIDLevel=(1 | 3 | 5)repositoryDrives=(trayID1,slotID1 ... trayIDn,slotIDn)[trayLossProtect=(TRUE | FALSE)]

    This command creates the mirror repository volume and activates the Remote

    Volume Mirror feature. This command enables users to define which physical

    disks will be used for the repository volume.

    activate storageArray feature=remoteMirrorrepositoryVolumeGroup=volumeGroupNumber

    [freeCapacityArea=freeCapacityIndexNumbertrayLossProtect=(TRUE | FALSE)]

    This command creates the mirror repository volume and activates the Remote

    Volume Mirroring feature. This command enables users to define the volume

    group in which the repository volume will be located.

    activate storageArray feature=remoteMirrorrepositoryRAIDLevel=(1 | 3 | 5)repositoryDriveCount=numberOfDrives[driveType=(fibre | SATA | PATA)trayLossProtect=(TRUE | FALSE)]

    This command creates the mirror repository volume and activates the RemoteVolume Mirroring feature. This command enables users to define the number

    of physical disks to be used for the repository volume.

    activate storageArray firmware

    This command activates firmware previously downloaded to the pending

    configuration area on the controllers in the storage array.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    34/62

    Command Line Interface and Script Commands Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . .

    24 SANtricityStorage Manager CLI Quick Reference for Version 9.25

    autoConfigure

    autoConfigure storageArray [driveType=(fibre | SATA | PATA)raidLevel=(0 | 1 | 3 | 5) volumeGroupWidth=numberOfDrives

    volumeGroupCount=numberOfVolumeGroups

    volumesPerGroupCount=numberOfVolumesPerGrouphotSpareCount=numberOfHotsparessegmentSize=segmentSizeValuereadAheadMultiplier=multiplierValue]

    This command automatically configures a storage array. Before entering the

    this command, enter the show storageArray autoConfigurationcommand to return a list of valid physical disk types, RAID levels, volume

    information, and hot spare information. If you want to modify the

    configuration, you can change the parameters to meet your configuration

    requirements. You can change a single parameter or all parameters. After you

    enter the autoConfigure storageArraycommand, the controllers setup the storage array by using either the default parameters or those you

    selected.

    autoConfigure storageArray hotSpares

    This command automatically defines and configures the hot spares in a storage

    array. You can run this command at any time. This command provides the best

    hot spare coverage for a storage array.

    check

    check remoteMirror localVolume [volumeName] optimalStatustimeout=timeoutValue

    This command returns the status of a Remote Volume Mirror. Use thiscommand to determine when Remote Volume Mirror status becomes Optimal.

    check volume [volumeName] parity [parityErrorFile=filename][mediaErrorFile=filename] [priority=(highest | high | medium |low | lowest)] [startingLBA=LBAvalue] [endingLBA=LBAvalue][verbose=(TRUE|FALSE)]

    This command checks a volume for parity and media errors and writes the

    results of the check to a file.

    clear

    clear allDriveChannels stats

    This command resets the statistics for all physical disk channels.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    35/62

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Script Commands

    SANtricityStorage Manager CLI Quick Reference for Version 9.25 25

    clear storageArray configuration

    This command clears the entire configuration from the controllers in a storage

    array. Information defining all volume groups, volumes, and hot spares is

    deleted. Use this command when you need to create a new configuration on a

    storage array that already has a configuration defined.

    Caution:

    Potential storage array configuration damage As soon as you run this

    command, the existing storage array configuration is deleted.

    clear storageArray eventLog

    This command clears the storage array event log by deleting the data in the

    Event Log buffer.

    Caution:

    Potential storage array configuration damage As soon as you run thiscommand, the existing Event Log in the storage array is deleted.

    clear storageArray firmwarePendingArea

    This command deletes from the pending area buffer a firmware image or

    nonvolatile static random access memory (NVSRAM) values you have

    previously downloaded.

    Caution:

    Potential storage array configuration damage As soon as you run this

    command, the contents of the existing pending area in the storage array are

    deleted.

    clear (allVolumes | volume [volumeName] |volumes [volumeName1 ... volumeNamen]) reservations

    This command clears persistent volume reservations.

    clear (allVolumes | volume [volumeName] |volumes [volumeName1 ... volumeNamen]) unreadableSectors

    This command clears unreadable sector information from one or more

    volumes.

    create

    create host userLabel=hostName[hostGroup=(hostGroupName|defaultGroup)]

    This command creates a new host object. If you do not specify a host group in

    which to create the new host, it is created in the default group.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    36/62

    Command Line Interface and Script Commands Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . .

    26 SANtricityStorage Manager CLI Quick Reference for Version 9.25

    create hostGroup userLabel=hostGroupName

    This command creates a new host group.

    create hostPort identifier=wwnuserLabel=portLabel

    host=hostName[hostType=(hostTypeIndexLabel| hostTypeIndexNumber)]

    This command creates a new host port object.

    create volume driveCount=numberOfDrivesraidLevel=(0 | 1 | 3 | 5)userLabel=volumeName[driveType=(fibre | SATA | PATA)capacity=volumeCapacityowner=(a | b)readAheadMultiplier=multiplierValue

    segmentSize=segmentSizeValueusageHint=(fileSystem | dataBase | multiMedia)trayLossProtect=(TRUE | FALSE)]

    This command creates a volume group across the storage array physical disks

    and a new volume in the volume group. The storage array controllers choose

    the physical disks to be included in the volume.

    Important:

    If you have physical disks with different capacities, you cannot automatically

    create volumes by specifying the driveCountparameter. If you want tocreate volumes with disks of different capacities, use the following createvolume drivescommand.

    create volume volumeGroup=volumeGroupNumberuserLabel=volumeName[freeCapacityArea=freeCapacityIndexNumbercapacity=volumeCapacityowner=(a | b)readAheadMultiplier=multiplierValuesegmentSize=segmentSizeValueusageHint=(fileSystem | dataBase | multiMedia)]

    This command creates a volume in the free space of a volume group.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    37/62

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Script Commands

    SANtricityStorage Manager CLI Quick Reference for Version 9.25 27

    create volume drives=(trayID1,slotID1...trayIDn,slotIDn)raidLevel=(0 | 1 | 3 | 5)userLabel=volumeName[capacity=volumeCapacity

    owner=(a | b)readAheadMultiplier=multiplierValuesegmentSize=segmentSizeValueusageHint=(fileSystem | dataBase | multiMedia)trayLossProtect=(TRUE | FALSE)]

    This command creates a new volume group and volume and enables you to

    specify the physical disks for the volume.

    Important:

    You cannot use mixed physical disk types in the same volume group and

    volume. This command fails if you specify different types of physical disks for

    the RAID volume.

    create remoteMirror primary=primaryVolumeNamesecondary=secondaryVolumeName(remotestorageArrayName=storageArrayName|remoteStorageArrayWwn=wwn) [remotePassword=passwordsyncPriority=(highest | high | medium | low | lowest)

    writeOrder=(preserved | notPreserved)writeMode=(synchronous | asynchronous)]

    This command creates both the primary and secondary volumes for a Remote

    Volume Mirror. This command also sets the write mode (synchronous or

    asynchronous) and synchronization priority.

    create snapshotVolume baseVolume=baseVolumeName[repositoryRAIDLevel=(1 | 3 | 5)repositoryDrives=(trayID1,slotID1 ... trayIDn,slotIDn)userLabel=snapshotVolumeName

    warningThresholdPercent=percentValuerepositoryPercentOfBase=percentValuerepositoryUserLabel=repositoryNamerepositoryFullPolicy=(failBaseWrites | failSnapShot)trayLossProtect=(TRUE | FALSE)]

    This command creates a snapshot volume. This command enables users to

    define which physical disks will be used for the snapshot repository volume.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    38/62

    Command Line Interface and Script Commands Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . .

    28 SANtricityStorage Manager CLI Quick Reference for Version 9.25

    create snapshotVolume baseVolume=baseVolumeName[repositoryVolumeGroup=volumeGroupNumberfreeCapacityArea=freeCapacityIndexNumber][userLabel=snapshotVolumeName

    warningThresholdPercent=percentValuerepositoryPercentOfBase=percentValuerepositoryUserLabel=repositoryNamerepositoryFullPolicy=(failBaseWrites | failSnapShot)trayLossProtect=(TRUE | FALSE)]

    This command creates a snapshot volume. This command enables users to

    define the volume group in which the snapshot repository volume will be

    located.

    create snapshotVolume baseVolume=baseVolumeName[repositoryRAIDLevel=(1 | 3 | 5)repositoryDriveCount=numberOfDrivesdriveType=(fibre | SATA | PATA) userLabel=snapshotVolumeName

    warningThresholdPercent=percentValuerepositoryPercentOfBase=percentValuerepositoryUserLabel=repositoryNamerepositoryFullPolicy=(failBaseWrites | failSnapShot)trayLossProtect=(TRUE | FALSE)]

    This command creates a snapshot volume. This command enables users to

    define the number of physical disks for the snapshot volume. The controller

    firmware chooses which physical disks to use for the snapshot volume.

    create volumeCopy source=sourceNametarget=targetName

    [copyPriority=(highest | high | medium | low | lowest)targetReadOnlyEnabled=(TRUE | FALSE)]

    This command creates a volume copy and starts the volume copy operation.

    Important:

    You can have a maximum of eight volume copies in progress at one time. If

    you try to create more than eight volume copies at one time, the controllers

    return a status of Pending until one of the volume copies that is in process

    finishes and returns a status of complete.

    deactivate

    deactivate storageArray feature=remoteMirror

    This command deactivates the Remote Volume Mirroring feature and

    disassembles the mirror repository volume. The host port dedicated to the

    Remote Volume Mirror is made available for host I/O activity.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    39/62

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Script Commands

    SANtricityStorage Manager CLI Quick Reference for Version 9.25 29

    delete

    delete host [hostName]

    This command deletes a host.

    delete hostGroup [hostGroupName]

    This command deletes a host group.

    delete hostPort [hostPortName]

    This command deletes a host port.

    delete (allVolumes | volume [volumeName] |volumes [volumeName1 ... volumeNamen])

    This command deletes one or more standard volumes or snapshots and

    snapshot repository volumes.

    Caution:

    Potential storage array configuration damage All data in the volume is

    lost as soon as you run this command.

    delete volumeGroup [volumeGroupNumber]

    This command deletes an entire volume group and its associated volumes.

    Caution:

    Potential storage array configuration damage All data in the volume

    group is lost as soon as you run this command.

    diagnose

    diagnose controller [(a | b)]loopbackDriveChannel=(allchannels | (1 | 2 | 3 | 4))testID=(1 | 2 | 3 | discreteLines) [patternFile=filename]

    This command runs diagnostic tests on the controller. The diagnostic tests

    consist of loop-back tests in which data is written to physical disks and read

    from the physical disks.

    diagnose remoteMirror (primary [primaryVolumeName] |primaries [primaryVolumeName1 ... primaryVolumeNamen])testID=connectivity

    This command tests the connection between the specified primary volumes and

    mirror volumes on a storage array with the Remote Volume Mirroring feature

    installed.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    40/62

    Command Line Interface and Script Commands Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . .

    30 SANtricityStorage Manager CLI Quick Reference for Version 9.25

    disable

    disable storageArray feature=(storagePartition2 |storagePartition4 | storagePartition8 | storagePartition16 |

    storagePartition64 | storagePartitionMax | snapshot |remoteMirror | volumeCopy)

    This command disables a storage array feature. Issue the showstorageArraycommand to display a list of the feature identifiers for allenabled features in the storage array.

    download

    download drive [trayID,slotID] firmware file=filename

    This command downloads a firmware image to a physical disk.

    download (allTrays | tray [trayID]) firmware file=filename

    This command downloads module firmware.

    download storageArray driveFirmware file=filename[file=filename2...file=filenameN]

    This command downloads firmware images to all physical disks in the storage

    array.

    download storageArray firmware [, NVSRAM ] file=filename[, NVSRAM-filename] [downgrade=(TRUE | FALSE)][activateNow=(TRUE | FALSE)]

    This command downloads firmware and, optionally, NVSRAM values for the

    storage array controller. If you want to download only NVSRAM values, usethe downLoad storageArray NVSRAMcommand.

    download storageArray NVSRAM file=filename

    This command downloads NVSRAM values for the storage array controller.

    enable

    enable controller [(a | b)] dataTransfer

    This command revives a controller that has become quiesced while running

    diagnostics.

    enable storageArray feature file=filename

    This command enables a feature using a feature key file.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    41/62

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Script Commands

    SANtricityStorage Manager CLI Quick Reference for Version 9.25 31

    recopy

    recopy volumeCopy target [targetName] [source [sourceName]][copyPriority=(highest | high | medium | low | lowest)

    targetReadOnlyEnabled=(TRUE | FALSE)]This command reinitiates a volume copy operation using an existing volume

    copy pair.

    recover

    recover volume (drive=(trayID,slotID) |drives=(trayID1,slotID1 ... trayIDn,slotIDn) |volumeGroup=volumeGroupNumberuserLabel=volumeNamecapacity=volumeCapacityoffset=offsetValueraidLevel=(0 | 1 | 3 | 5) segmentSize=segmentSizeValue[owner=(a | b) readAheadMultiplier=multiplierValue]

    This command creates a RAID volume with the given properties withoutinitializing any of the user data areas on the disks. Parameter values are derived

    from the Recovery Profile data file for the storage array.

    recreate

    recreate storageArray mirrorRepositoryrepositoryRAIDLevel=(1 | 3 | 5)repositoryDrives=(trayID1,slotID1... trayIDn,slotIDn)[trayLossProtect=(TRUE | FALSE)]

    This command creates a new Remote Volume Mirror repository volume using

    the parameters defined for a previous Remote Volume Mirror repository

    volume. The underlying requirement is that you have previously created a

    Remote Volume Mirror repository volume. This command enables users to

    define which physical disks will be used for the Remote Volume Mirror

    repository volume.

    recreate storageArray mirrorRepositoryrepositoryVolumeGroup=volumeGroupNumber[freeCapacityArea=freeCapacityIndexNumber]

    This command creates a new Remote Volume Mirror repository volume using

    the parameters defined for a previous Remote Volume Mirror repository

    volume. The underlying requirement is that you have previously created a

    Remote Volume Mirror repository volume. This command enables users todefine the volume group in which the Remote Volume Mirror repository

    volume will be located.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    42/62

    Command Line Interface and Script Commands Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . .

    32 SANtricityStorage Manager CLI Quick Reference for Version 9.25

    recreate storageArray mirrorRepositoryrepositoryRAIDLevel=(1 | 3 | 5)repositoryDriveCount= numberOfDrives[driveType=(fibre | SATA | PATA) trayLossProtect=(TRUE | FALSE)]

    This command creates a new Remote Volume Mirror repository volume using

    the parameters defined for a previous Remote Volume Mirror repository

    volume. The underlying requirement is that you have previously created a

    Remote Volume Mirror repository volume. This command enables users to

    define the number of physical disks to be used for the Remote Volume Mirror

    repository volume.

    recreate snapshot (volume [volumeName] |volumes [volumeName1 ... volumeNamen])[userLabel=snapshotVolumeName

    warningThresholdPercent=percentValuerepositoryFullPolicy=(failBaseWrites | failSnapShot)]

    This command starts a fresh copy-on-write operation using an existing

    snapshot volume.

    remove

    remove remoteMirror (localVolume [volumeName] |localVolumes [volumeName1 ... volumeNamen])

    This command removes the mirror relationship between the primary volume

    and secondary volume.

    remove volumeCopy target [targetName] [source [sourceName]]

    This command removes a volume copy pair.

    remove (allVolumes | volume [volumeName] |volumes [volumeName1 ... volumeNamen] | accessVolume) lunMapping(host=hostName| hostGroup=(hostGroupName| defaultGroup))

    This command removes the logical unit number mapping.

    repair

    repair volume [volumeName] parity parityErrorFile=filename[verbose=(TRUE | FALSE)]

    This command repairs the parity errors on a volume.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    43/62

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Script Commands

    SANtricityStorage Manager CLI Quick Reference for Version 9.25 33

    reset

    reset controller [(a | b)]

    This command resets a controller.

    Important:

    When you reset a controller, the controller is not available for I/O operations

    until the reset is complete. If a host is using volumes owned by the controller

    being reset, the I/O directed to the controller will be rejected. Before resetting

    the controller, either verify that the volumes owned by the controller are not in

    use or ensure that a multi-path driver is installed on all hosts using these

    volumes.

    reset storageArray batteryInstallDate [controller=(a | b)]

    This command resets the age of the batteries in a storage array to zero days.

    You can reset the batteries for an entire storage array or the battery in a specificcontroller. The E6000 command module does not support this command.

    reset storageArray diagnosticData

    This command resets the NVSRAM that contains the storage array diagnostic

    data. This command, however, does not delete the diagnostic data. This

    command replaces the Needs Attention status with the Diagnostic Data

    Available status. The old diagnostic data is then automatically written over

    when new data is captured. The memory that contains the diagnostic data is

    also cleared when the controllers reboot. Before resetting the diagnostic data,

    use the save storageArray diagnosticDatacommand to save thediagnostic data to a file.

    reset storageArray RLSBaseline

    This command resets the Read Link Status (RLS) baseline for all devices.

    reset storageArray SOCBaseline

    This command resets the baseline for all switch-on-a-chip (SOC) devices

    accessed through the controllers. This command resets the baseline by setting

    all SOC counts to 0. This command is valid only for Fibre Channel devices in

    an Arbitrated Loop topology.

    reset storageArray volumeDistribution

    This command reassigns (moves) all volumes to their preferred controller.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    44/62

    Command Line Interface and Script Commands Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . .

    34 SANtricityStorage Manager CLI Quick Reference for Version 9.25

    resume

    resume remoteMirror (primary [volumeName] |primaries [volumeName1 ... volumeNamen])

    writeConsistency=(TRUE | FALSE)This command resumes a suspended Remote Volume Mirroring operation.

    revive

    revive drive [trayID,slotID]

    This command forces the specified physical disk to the Optimal state.

    revive volumeGroup [volumeGroupNumber]

    This command forces the specified volume group and associated failed

    physical disks to the Optimal state.

    Caution:

    Possible data corruption or data loss Correct use of this command depends

    on the data configuration on all physical disks in the volume group. Never

    attempt to revive a physical disk unless supervised by a Customer and

    Technical Support representative.

    save

    save controller [(a | b)] NVSRAM file=filename

    This command saves a copy of the controller NVSRAM values to a file. This

    command saves all regions.

    save allDrives logFile=filename

    This command saves the log sense data to a file. Log sense data is maintained

    by the storage array for each physical disk.

    save storageArray configuration file=filename[(allconfig | globalSettings=(TRUE | FALSE)volumeConfigAndSettings=(TRUE | FALSE)hostTopology=(TRUE | FALSE) lunMappings=(TRUE | FALSE))]

    This command creates a script file that you can use to create the current storage

    array volume configuration.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    45/62

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Script Commands

    SANtricityStorage Manager CLI Quick Reference for Version 9.25 35

    save storageArray diagnosticData [(controller | esm)]file=filename

    This command saves the storage array diagnostic data from either the

    controllers or the environmental service monitors (ESMs) to a file. You can

    review the file contents at a later time. You can also send the file to a Customer

    and Technical Support representative for further review. After you have saved

    the diagnostic data, you can reset the NVSRAM registers that contain the

    diagnostic data so that the old data can be overwritten. Use the resetstorageArray diagnosticDatacommand to reset the diagnostic dataregisters.

    save storageArray (allEvents | criticalEvents) file=filename[count=numberOfEvents]

    This command saves events from the Major Event Log (MEL) to a file. You

    can save either all the events or only the critical events.

    save storageArray performanceStats file=filename

    This command saves the performance statistics to a file. Before you use this

    command, issue the set session performanceMonitorIntervaland set session performanceMonitorIterationscommands tospecify how often statistics are collected.

    save storageArray RLSCounts file=filename

    This command saves the Read Link Status (RLS) counters to a file. Before

    using this command, issue the reset storageArray RLSBaselinecommand to get current data.

    save storageArray SOCCounts file=filename

    This command saves the SOC error statistics to a file. This command is valid

    only for Fibre Channel devices in an Arbitrated Loop topology.

    save storageArray stateCapture file=filename

    This command saves the state capture to a file.

    save storageArray supportData file=filename

    This command saves the support-related information to a file.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    46/62

    Command Line Interface and Script Commands Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . .

    36 SANtricityStorage Manager CLI Quick Reference for Version 9.25

    set

    set controller [(a | b)]availability=(online | offline | serviceMode) |

    bootp |ethernetPort [(1 | 2)] ipAddress=ipAddress|gatewayIPAddress=ipAddress|globalNVSRAMByte [nvsramOffset]=(nvsramByteSetting|nvsramBitSetting) |hostNVSRAMByte [hostType, nvsramOffset]=(nvsramByteSetting|nvsramBitSetting) |ipAddress=ipAddress|rloginEnabled=(TRUE | FALSE) |subnetMask=ipAddress

    This command defines the properties for the controllers.

    set controller=[(a | b)] serviceAllowedIndicator=(on | off)

    This command turns on or turns off the Service Action Allowed indicator light

    on an E6000 command module controller. This command is valid only for

    E6000 command modules. (To turn on or turn off the Service Action Allowed

    indicator light on the power-fan canister or interconnect-battery canister in an

    E6000 command module, use the set trayserviceAllowedIndicatorcommand.)

    set driveChannel [(1 | 2 | 3 | 4)] status=(optimal | degraded)

    This command defines how the physical disk channel performs.

    set (drive [trayID,slotID] |drives [trayID1,slotID1 ... trayIDn,slotIDn])hotSpare=(TRUE | FALSE)

    This command assigns or unassigns one or more physical disks as a hot spare.

    set drive [trayID,slotID] operationalState=failed

    This command sets a physical disk to the failed state. (To return a physical disk

    to the Optimal state, use the revive drivecommand.)

    set (drive [trayID,slotID] | drives [trayID1,slotID1 ...trayIDn,slotIDn]) serviceAllowedIndicator=(on | off)

    This command turns on or turns off the Service Action Allowed indicator lighton a physical disk in the FC-4 16x drive module. If the storage array does not

    support the Service Action Allowed indicator light feature, this command

    returns an error. If the storage array supports the command but is unable to turn

    on or turn off the indicator light, this command returns an error.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    47/62

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Script Commands

    SANtricityStorage Manager CLI Quick Reference for Version 9.25 37

    set host [hostName] hostGroup=(hostGroupName| none |defaultGroup) userLabel=newHostName

    This command assigns a host to a host group or moves a host to a different host

    group. You can also create a new host group and assign the host to the new host

    group with this command. The actions performed by this command depend on

    whether the host has individual volume-to-LUN mappings or does not have

    individual volume-to-LUN mappings.

    set hostChannel [(a1 | a2 | b1 | b2)] preferredID=portID

    This command defines the loop ID for the host channel. For the E6000

    command module, valid host channel values are a1, a2, a3, a4, b1, b2, b3,

    or b4.

    set hostGroup [hostGroupName] userLabel=newHostGroupName

    This command renames a host group.

    set hostPort [portLabel] host=hostNamehostType=(hostTypeIndexLabel| hostTypeIndexNumber)userLabel=newPortLabel

    This command changes the host type for a host port. You can also change a

    host port label with this command.

    set remoteMirror (localVolume [volumeName] |localVolumes [volumeName1 ... volumeNamen])role=(primary | secondary) [force=(TRUE | FALSE)]syncPriority=(highest | high | medium | low | lowest)

    writeOrder=(preserved | notPreserved)writeMode=(synchronous | asynchronous)

    This command defines the properties for a Remote Volume Mirror pair.

    set session errorAction=(stop | continue)password=storageArrayPasswordperformanceMonitorInterval=intervalValueperformanceMonitorIterations=iterationValue

    This command defines how you want the current script engine session to run.

    set (volume [volumeName] |volumes [volumeName1 ... volumeNamen])

    userLabel=snapshotVolumeNamewarningThresholdPercent=percentValuerepositoryFullPolicy=(failBaseWrites | failSnapShot)

    This command defines the properties for a snapshot volume and enables you to

    rename a snapshot volume.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    48/62

    Command Line Interface and Script Commands Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . .

    38 SANtricityStorage Manager CLI Quick Reference for Version 9.25

    set storageArray alarm=(enable |disable | mute)cacheBlockSize=cacheBlockSizeValuecacheFlushStart=cacheFlushStartSizecacheFlushStop=cacheFlushStopSize

    defaultHostType=(hostTypeName | hostTypeIdentifier)failoverAlertDelay=delayValuemediaScanRate=(disabled | 1-30)password=passworduserLabel=storageArrayName

    This command defines the properties of the storage array.

    set storageArray redundancyMode=(simplex | duplex)

    This command sets the storage array redundancy mode to either simplex or

    duplex. Use simplex mode when you have a single controller. Use duplex mode

    when you have two controllers.

    set storageArray time

    This command sets the clocks on both controllers in a storage array bysynchronizing the controller clocks with the clock of the host from which you

    issue this command.

    set storageArray trayPositions=(controller | 0-99)

    This command defines the position of the modules in a storage array. You must

    include all modules in the storage array when you enter this command.

    set (allTrays | tray [trayID] alarm=(enable |disable | mute))

    This command turns on, turns off, or mutes the audible alarm for a specific

    module or all modules in a storage array.

    set tray [serial-number] id=80-99

    This command sets the ID of an E6000 command module in a storage array.

    The range of valid command module IDs is from 80 through 99. This range

    avoids conflicts with existing drive module IDs used for attached drive

    modules.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    49/62

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Script Commands

    SANtricityStorage Manager CLI Quick Reference for Version 9.25 39

    set tray [trayID] (powerFan [(left | right)] |interconnect | esm [(left | right)]) serviceAllowedIndicator=(on| off)

    This command turns on or turns off the Service Action Allowed indicator light

    on a power-fan canister, an interconnect-battery canister, or an environmental

    services monitor (ESM) canister. If the storage array does not support the

    Service Action Allowed indicator light feature, this command returns an error.

    If the storage array supports the command but is unable to turn on or turn off

    the indicator light, this command returns an error. (To turn on or turn off the

    Service Action Allowed indicator light on a controller in an E6000 command

    module, use the set controller serviceAllowedIndicatorcommand.)

    set (allVolumes | volume [volumeName] |volumes [volumeName1 ... volumeNamen] | volume )cacheFlushModifier=cacheFlushModifierValuecacheWithoutBatteryEnabled=(TRUE | FALSE)

    mediaScanEnabled=(TRUE | FALSE)mirrorCacheEnabled=(TRUE | FALSE)modificationPriority=(highest | high | medium | low | lowest)owner=(a | b) readCacheEnabled=(TRUE | FALSE)

    writeCacheEnabled=(TRUE | FALSE)readAheadMultiplier=integer-literal

    This command defines the properties for a volume. This command is applicable

    to one or more volumes.

    set (volume [volumeName] | volume )

    addCapacity=volumeCapacity[addDrives=(trayID1,slotID1 ... trayIDn,slotIDn)]redundancyCheckEnabled=(TRUE | FALSE)segmentSize=segmentSizeValueuserLabel=volumeName

    This command defines the properties for a volume. This command is applicable

    to only one volume.

    set (volume [volumeName] | volume | accessVolume)logicalUnitNumber=LUN(host=hostName |hostGroup=(hostGroupName | defaultGroup)

    This command defines the properties for a volume. This command is applicable

    to volume mapping.

    set volumeCopy target [targetName] [source [sourceName]]copyPriority=(highest | high | medium | low | lowest)targetReadOnlyEnabled=(TRUE | FALSE)

    This command defines the properties for a volume copy pair.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    50/62

    Command Line Interface and Script Commands Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . .

    40 SANtricityStorage Manager CLI Quick Reference for Version 9.25

    set volumeGroup [volumeGroupNumber]addDrives=(trayID1,slotID1... trayIDn,slotIDn)raidLevel=(0 | 1 | 3 | 5) owner=(a | b)availability=(online | offline)

    This command defines the properties for a volume group.

    show

    show (allControllers | controller [(a | b)]) [summary]

    For each controller in a storage array, this command returns status, physical

    characteristics, and configuration information.

    show (allControllers | controller [(a | b)]) NVSRAM[hostType=(hostTypeIndexLabel| host=hostName)]

    This command returns the NVSRAM bytes for the specified host type. If users

    do not enter the optional parameters, this command returns the entireNVSRAM.

    show (allDrives [driveType=(fibre | SATA | PATA)] |drive [trayID,slotID] |drives [trayID1,slotID1... trayIDn,slotIDn]) [summary]

    For each physical disk in the storage array, this command returns total number

    of physical disks, type of physical disk (Fibre, serial advanced technology

    attachment [SATA], or parallel advanced technology attachment [PATA]),

    basic physical disk information, physical disk channel information, hot spare

    coverage, and details for each physical disk.

    show (driveChannel [(1 | 2 | 3 | 4)] |driveChannels [(1 | 2 | 3 | 4) ... (1n | 2n | 3n | 4n)] |allDriveChannels) stats

    This command displays cumulative physical disk channel I/O and error

    information. If the controller has automatically degraded a channel, this

    command also displays interval statistics. When using this command, you can

    display information about one specific physical disk channel, several physical

    disk channels, or all physical disk channels.

    show allDrives downloadProgress

    This command returns the status of firmware downloads for the physical disks

    targeted by the download drive firmwareor downloadstorageArray driveFirmwarecommand.

    show allHostPorts

    For all host ports connected to a storage array, this command returns host port

    identifier, host port name, and host type.

  • 7/24/2019 SMcli and Script Commands Quick Reference for SANtricity Ver 9.25 ES1790-0-E1

    51/62

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Script Commands

    SANtricityStorage Manager CLI Quick Reference for Version 9.25 41

    show remoteMirror candidates primary=volumeNameremoteStorag