Top Banner
(c) Intelligent Gas Alarm India Pvt Ltd 1 Intelligent Gas Alarm India Pvt Ltd 69, Ramgali – 7, Raja Park Jaipur - 302 004 [email protected] www.gasalarm.co.in, www.automationindia.in Contact:
15

Smart Products for pressure, gas leakage, level, flow, temperature monitoring

May 15, 2015

Download

Business

GasAlarm India offers products and solutions for gas concentration monitoring in air & sample gas, pressure, differential pressure, temperature, flow, temperature, motion, brightness, lux, sound, radiation, humidity, moisture, smoke detection, process control and automation.
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Smart Products for pressure, gas leakage, level, flow, temperature monitoring

(c) Intelligent Gas Alarm India Pvt Ltd 1

Intelligent Gas Alarm India Pvt Ltd69, Ramgali – 7, Raja ParkJaipur - 302 [email protected], www.automationindia.in

Contact:

Page 2: Smart Products for pressure, gas leakage, level, flow, temperature monitoring

Gas Sensor product Range

•Sensors • MA series• ADT series (Analog , digital)• FT series• ADL series

•Standalone single point controller • Fixed type• Transportable (battery operated)

•ATEX Sensors - Explosion Proof

•Controllers (MGC03, SPC,

•Warning Devices

Page 3: Smart Products for pressure, gas leakage, level, flow, temperature monitoring

MA (uGard) Series:•Low cost yet effective measurement and monitoring•Building application orientation•Field-replaceable sensor cell and PCB (easy service)•Short circuit and reverse polarity protection•For CO, NO2 monitoring – in car parks, garage•For Combustible / Flammable in 0-100% LEL

• LPG, H2, CNG, Methane, propane, butane etc

•Other gases: O2, Ethylene, Freon, NH3 (EC), SO2•24 VDC, 4-20mA output, 2-10 VDC (optional)

Housing Options:IP44IP 65 IP54

Page 4: Smart Products for pressure, gas leakage, level, flow, temperature monitoring

ADT Series:•Plug-in sensor and PCB (easy service)•Short circuit and reverse polarity protection•For Toxic Gases - CO, NO2, SO2, H2S, Freon, Cl2, Ammonia etc•For Explosive / flammables gases in 0-100% LEL

• LPG, H2, CNG, Methane, propane, butane etc

•Other gases: O2, HCN, HCl, O3, PH3, Silane, SF6 etc.•24 VAC/DC•0-20mA output, 4-20mA, 0-10VDC 2-10 VDC•RS485, MODBUS, LON, BACnet (with Gateway)•Mounting – wall mount, duct mount, online•Housing Options:

• IP 65 (standard – as pictured)• Stainless Steel • Metal

•Certification – UL (USA), CE, VDI 2053, TUV

Page 5: Smart Products for pressure, gas leakage, level, flow, temperature monitoring

Freon Sensors• MA series (0-2000ppm, 4-20mA)• ADT-43-20xx (0-300 / 2000 ppmPPM, 4-20mA) • ADT-D3-20xx (0-2000ppm, multi-output, Infra-red cell)

NH3 Sensor• ADT-23-1120 / 25 (0-300/1000PPM, multi-output, -10oC - +40oC)• with heating ( -40oC - +10oC)

CO2 Sensor• ADT-D3-1164 (0-20,000 / 50,000ppm, multi-output, Infra-red cell)

Page 6: Smart Products for pressure, gas leakage, level, flow, temperature monitoring

ATEX Sensors (Explosion proof)•Available for Zone 1 & Zone 2•For all gases (O2, Methane, Ethylene, CO, CO2, H2S, CL2, NO, NO2 etc)•With or without LC Display•(DGMS, CoE)•Flameproof / Explosion proof

•For monitoring in ambient air, ground water contamination / soil contamination to meet EPA guidelines•For Oil/Gas, Petro-chemicals, Dangerous goods, Laboratories, Mining, Tunnels

Features:•With / without display•10-bit microprocessor based control unit for •Zero tracking, signal tracking•Reverse polarity, short circuit protected•RS485 modbus (optional)•Non-instrusive IR calibration (option)

Page 7: Smart Products for pressure, gas leakage, level, flow, temperature monitoring

Hazardous Area Installations:

America: Div 1, Zone 0 (Cont. hazard), Zone 1 (Intermittent Hazard), Div 2 or Zone 2 (Hazard under abnormal conditions)

CENELEC, BASSEFA, IEC Ex (Europe): Zone 0 (continuous), Zone 1 (Intermittent), Zone 2 (abnormal conditions)

India: Follows both ATEX, UL, FM, BASSEFA, IEC Ex (depends on the consultants)

Page 8: Smart Products for pressure, gas leakage, level, flow, temperature monitoring

Plastic IP65 (standard)

For low cost, buildings

Stainless Steel

(Vandal proof)

For corrosive places

IP 65 with splash guard

For out-doors, water splash

Duct Mount For Ducts

Heater For freezing temp.

Page 9: Smart Products for pressure, gas leakage, level, flow, temperature monitoring

• IP 65 Polycarbonate housing, Averaging, Mean-Value calculations• Option of 1 hour emergency back up with batteries, integral buzzer,

integral A-V Alarm• Fully Modular to build from 4 upto 98 Channel System

• Clear hinged door with option of lock• Password protected• Fail safe• Auto- diagnostic watch dog to meet critical system• RS485 Modbus, BACnet, LON Gateway• Datalogger (option)• Low / high alarm LEDs• Power on LEDs• Fault alarm LED (auto diagnostic watchdog - builds system error

codes)• Five alarm thresholds , assigning any alarm to any relay• Fully flexible, modular – 4,8,,12,16,20,24,28,32 channel

• Internal memory battery – facilitates pre-programming alarm configuration, alarm setting on lab bench-top

• Simple, Easy menu driven configuration (English)• Digital bus system (option)

Page 10: Smart Products for pressure, gas leakage, level, flow, temperature monitoring

PolyGard® Gas Controller MGC 04

Page 11: Smart Products for pressure, gas leakage, level, flow, temperature monitoring

PolyGard® Gas Controller MGC 03-02-02•1, 2 Measuring Point •2 Alarm relay•Low, high alarm LEDs•Integral buzzer•Power ON LED•Fault LED (auto diagnostic watch dog – builds error code, required for critical safety system•IP65 weather proof•Plug-in PCB for easy service and replacement•24V AC/DC power supply (220V AC option)•Analog output X 1 (4-20mA / 2-10V)•Easy simple programming configuration (English menu driven language)

Page 12: Smart Products for pressure, gas leakage, level, flow, temperature monitoring

SPC-X3•Integral built-in sensor cell (EC, Ex-Cat, NDIR, Semiconductor) •2 Alarm relay•Low, high alarm LEDs•Integral buzzer•Power ON LED•Fault LED (auto diagnostic watch dog – builds error code, required for critical safety system•IP65 weather proof•Plug-in PCB for easy service and replacement•24V AC/DC power supply (220V AC option)•Analog output X 1 (4-20mA / 2-10V)•Easy simple programming configuration (English menu driven language) •In-built battery (rechargeable for transportable application)(option)•Battery backup optional

Page 13: Smart Products for pressure, gas leakage, level, flow, temperature monitoring

ADL-X1•Integral built-in sensor cell (EC, Ex-Cat, NDIR, Semiconductor) •Integral memory size : 16,000 readpoints•Configurable recording interval: 2 sec to 5 hrs•Data readout by USB port•In-built battery (rechargeable for transportable application)(option)•Analog output X 1 (4-20mA / 2-10V)•Easy simple programming configuration (English menu driven language) •In-built battery (rechargeable for transportable application)(option)

Page 14: Smart Products for pressure, gas leakage, level, flow, temperature monitoring

GAS-HF

24VDC Combo siren/strobe

Lo Alarm: Flasher (Red)

Hi-Alarm: Siren (105dB)

Page 15: Smart Products for pressure, gas leakage, level, flow, temperature monitoring

Australian Exposure Standards for Atmospheric Contaminants in the Occupational Environment NOHSC: 3008 (1995) has set some TWA standards which are followed by various OH&S Statutory Bodies as well as referred by Standards (AS 1668.2 etc) – some typical TWA (for others refer to USA-ACGIH, OSHA, NIOSH)

NH3: TWA – 25 ppm, STEL – 35 ppmCO2: TWA – 5000 ppm, STEL – 30000 ppmCO: TWA – 30 ppm, STEL- 200 ppmH2S: TWA – 10 ppm, STEL- 15 ppmNO2: TWA – 3 ppm, STEL – 5 ppmNO (Nitric Oxide): TWA - 25 ppmN2O3 (Nitrous Oxide): TWA - 25 PPM (hospitals)Cl2 (Chlorine): TWA – 1 ppmO2 (Oxygen): 19 % Vol (minimum), Air has 20.9 % O2O3 (Ozone): TWA – 0.1 ppm