Density Sensor Adapter Inlet Inlet Tube Thermowell Shown with pipe plugs inserted Outlet Slipstream™ Density Measurement System Direct Density Measurement System Slipstream™ Density Measurement System General Information Components The Slipstream™ Density Measurement System (SDMS) is an add-on density measurement system for the Liquid Controls and Avery-Hardoll Flowmeters. The SDMS re-routes fuel from the outlet side of the meter through the densitometer and back into the outlet side of the meter. The Densitometer measures the density of the fuel throughout the duration of a fueling and sends real- time density measurements to the LectroCount® LCR 600 electronic or MASTERLOAD III registers. The registers display the real-time fuel density during fueling. The average density and the total weight of fueling are printed on the fueling ticket. M-80 flowmeters with the SDMS typically include a POD pulser, a LectroCount LCR 600 electronic register, and an ETVC (electronic temperature volume compensation). A density sensor adapter kit is available separately. The adapter kit allows SDMS installation at a later date without removing any piping from the system. There are four major components in the Slipstream Density Measurement System: the Densitometer, the Density Sensor Adapter, the Fuel Sample Valve, and the Shut Off Valve. www.lcmeter.com Density Sensor Adapter LCMass Densitometer Shut Off Valve Test Sample Valve
2

Slipstream™ Density Measurement System

Jul 25, 2016

Download

Documents

Liquid Controls

The Slipstream™ Density Measurement System (SDMS) is an add-on density measurement system for Liquid Controls and Avery-Hardoll Flowmeters. The SDMS re-routes fuel from the outlet side of the meter through the densitometer and back into the outlet side of the meter. The Densitometer measures the density of the fuel throughout the duration of a fueling and sends realtime density measurements to the LectroCount® LCR 600 electronic or MASTERLOAD III registers. • The registers display the real-time fuel density during fueling. • The average density and the total weight of fueling are printed on the fueling ticket.
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Slipstream™ Density Measurement System

Density Sensor Adapter

Inlet

Inlet TubeThermowell

Shown with pipe plugs inserted

Outlet

Slipstream™ Density Measurement System

Direct Density Measurement System

Slip

stre

am

™ D

ensity

Measure

ment S

yste

m

General Information

Components

The Slipstream™ Density Measurement System (SDMS) is an add-on density measurement system for the Liquid Controls and Avery-Hardoll Flowmeters. The SDMS re-routes fuel from the outlet side of the meter through the densitometer and back into the outlet side of the meter.The Densitometer measures the density of the fuel throughout the duration of a fueling and sends real-time density measurements to the LectroCount® LCR 600 electronic or MASTERLOAD III registers.• The registers display the real-time fuel density during fueling.• The average density and the total weight of fueling are printed on the fueling ticket.M-80 flowmeters with the SDMS typically include a POD pulser, a LectroCount LCR 600 electronic register, and an ETVC (electronic temperature volume compensation).A density sensor adapter kit is available separately. The adapter kit allows SDMS installation at a later date without removing any piping from the system.There are four major components in the Slipstream Density Measurement System: the Densitometer, the Density Sensor Adapter, the Fuel Sample Valve, and the Shut Off Valve.

www.lcmeter.com

Density Sensor Adapter

LCMass Densitometer

Shut Off ValveTest Sample Valve

Page 2: Slipstream™ Density Measurement System

Slipstream™ Density Measurement SystemSlipstr

eam

™ D

ensit

y M

easure

ment

Syste

m

Liquid Controls105 Albrecht Dr.

Lake Bluff, IL 60044www.lcmeter.comCopyright © 2015 Liquid Controls Pub. 500000 (10/15) MS500-10

Average Density Monitoring

Sample Ticket Densitometer Specs

Accuracy Digital Density: 0.0001 g/ccAnalog Density: +/- 0.1% of full scaleTemperature: 0.6 °F (0.3 °C)Repeatability: 0.00003 max g/cc

Max Pressure 300 psig (21.7 bar) standard

Operating Temperature -4 to 140 F (-20 to 60 C)

Sample Rate 100 mS

Power Supply 5 VDC, 500 mW USB or 8-30 VDC

Consumption 400 mW

Outputs (2) 4-20mA analog, optional

Communication USB, standard RS-232, optional RS-485, optional

ApprovalsEX IIC, AEx, CUL, UL (Class 1 Div 1, Group

Current Average Density Reading