Top Banner
Fire Fighting Systems and Equipments Fire Fighting Systems and Equipments http://www.sea-plus.co.kr
24
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Seaplus Fire Fighting Systems

Fire Fighting Systems and Equipments

Fire Fighting Systems and Equipments

http://www.sea-plus.co.kr

Page 2: Seaplus Fire Fighting Systems

Go with SEAPLUS for your safety offire extinguishing systems,

equipments, and others

G o w i t h SEAPLUS f o r y o u r s a f e t y o f f i r e e x t i n g u i s h i n g s y s t e m s , e q u i p m e n t s , a n d o t h e r s

SEAPLUS for your safety life - 2Page

Page 3: Seaplus Fire Fighting Systems

Introduction 04PageCompany history 05Page

External fire fighting system 06~07PageWater mist fire extinguishing system 08~09Page

High expansion foam fire extinguishing system 10PageDeck foam fire extinguishing system 11Page

High pressure CO2 fire extinguishing system 12PageLow pressure CO2 fire extinguishing system 13Page

Dry chemical powder fire extinguishing system 14PageAutomatic sprinkler fire extinguishing system 15Page

Fire detection & alarm system 16PageLoose fire fighting equipment 17PageQuality certification 18PageTotal fire test shop 19PageWorld wide a/s net work 20~21PagePlant project team 22~23Page

Index

Fire Fighting Systems and Equipments

SEAPLUS for your safety life - 3Page

Page 4: Seaplus Fire Fighting Systems

SEAPLUS for your safety life - 4Page

GO with SEAPLUS for your safety of fire extinguishing systems and equipments.

Page 5: Seaplus Fire Fighting Systems

Company history

Introduction

1994 7 Established DAE KYEONG Engineering Co.1997 4 Incorporated as "SEAPLUS CO., LTD."1999 7 Acquisition for license of Fire protection system construction by Busan city1999 9 Certified ISO 9001 by KOREAN REGISTER of SHIPPING2000 4 Moved the factory & office to NOKSAN industrial complex2001 4 Technical R & D Lab. Approved by KITA2001 6 Established Total fire test shop2002 5 Designated as Venture Business2002 6 Developed Local fire fighting system in According with MSC Circ.9132002 7 Certified as technology-innovating SME (INNO-BIZ) business by

Small & Medium Business Administration2003 9 Awarded Presidential citation2004 12 Awarded Advance Idea Man (New Knowledge Man)2006 10 Developed Total Application Water mist fire extinguishing system in

According with MSC Circ.11652006 12 Selected as "Leading Enterprise in Strategic Industry" by Busan city2007 8 Chosen as Promising Enterprise by WOORI BANK2007 10 Developed Self-rotation type high expansion foam generator2008 7 Established 2nd manufacturing factory2008 7 Superiority Business man Awarding by Busan city2008 10 Awarded the Prime Minister2008 11 Acquisition for license of Fire protection system design by Busan city2008 12 Awarded "Commendation for Genuine S/W User" by Minister of Culture, Sports and Tourism

SEAPLU

S for your safety life

SEAPLUS for your safety life - 5Page

SEAPLUS CO., LTD. is one of leaders and manufacturers for fire fightingsystems & safety equipment in Korea and we have taken our expertise &experience into the world wide market to establish a reputation forexcellence and customer support.We are confident that you will find our presentation of interest and assureyou of our competence and desire to realize your contract in away totallysatisfactory to you, our prospective client.

Page 6: Seaplus Fire Fighting Systems

External Fire Fighting System

In fire fighting system, the external fire fighting system is to extinguish and suppressfires against external vessel. It is equipped with fire monitor, fire fighting pump,electric motor, portable controller and fire monitor and so on. Fire fighting pump canbe driven by transmission power from driven-engine or dedicated motor.According to mounting location of fire monitor, there are sliding tower, folding towerand platform on wheel house. Tower's characteristic is to be folded and storaged in a low and compact size. Itwould significant facilitate handling on fire suppression and extinguishing using dualmonitor of foam liquid and dry powder.

Water monitor system capacity (ABS Rule 5-9-1/Table.1, 2006)

Class Notation

Number of water monitors

Discharge rate per monitor, m3/h

Number of pumps

Total capacity, m3/h

Monitor range, m

Height, monitor, m

Number of hose connection each side of vessel

Number of fireman's outfits

Fuel oil capacity

Class

2

1,200

1-2

2,400

120

45

4

4

24

Class

3 4

2,400 1,800

2-4

7,200

150

70

8

8

96

Class

4

2,400

2-4

9,600

150

70

10

10

96

1) Range : measured horizontally from the monitor outlet to the mean impact area.2) Height : minimum height of the trajectory of water monitor jet measured vertically from sea level assuming a mean impact area

located at a horizontal distance not less than 70m from the nearest part of the fire fighting vessel.3) Fuel oil capacity is to include provisions for continuous operation of all monitors in addition to the total capacity

of the vessel's fuel oil tanks required for continuous fire fighting operation. See also 5-9-2/5.

SEAPLU

S for your safety life

Controller Fire Pump Unit

SEAPLUS for your safety life - 6Page

Page 7: Seaplus Fire Fighting Systems

FE-65FE-80FE-100FE-125FE-150FE-200

FE-200DSFE-200

SFE-200SSFE-200D

SFE-200DSFEH-200

FEH-200DFEH-250FEH-300

500 ~ 1,5001,500 ~ 3,0003,000 ~ 5,0005,000 ~ 8,000 8,000 ~ 11,333

11,333 ~ 20,000

11,333 ~ 25,000

25,000 ~ 40,000 40,000 ~ 60,000

30 ~ 9090 ~ 180

180 ~ 300300 ~ 480 480 ~ 680

680 ~ 1,200

680 ~ 1,500

1,500 ~ 2,400 2,400 ~ 3,600

ElectricElectricElectricElectricElectricElectricElectricElectricElectricElectricElectric

Electro-HydraulicElectro-HydraulicElectro-HydraulicElectro-Hydraulic

Double Gun

Double GunDouble Gun

Double Gun

ModelCapacity

Actuating Method RemarkL/min m3/h

Discharge of Fire Monitor

Sliding Tower

Portable ControllerFolding Tower

SEAPLUS for your safety life - 7Page

Page 8: Seaplus Fire Fighting Systems

Water Mist Fire Extinguishing System

Using spraying water in all fires, the water mist system is to suppress and fight all fires inprotected areas. In this fire extinguishing system, water is sprayed in high or low pressureto make small water droplets. Using water droplets, vaporization effect gets increased asmuch as surface area expansion. Water mist is sprayed into flame so that to promotevaporization and decrease in oxygen concentration as suffocation. Extinguishing effectbecomes increased by cooling. The system has two types of local fire fighting system andtotal fire fighting system. Especially, in case of local application, it is designed andinstalled to cover main engine, aux. engine, boiler, incinerator and purifiers as protectedarea respectively. The arrangements of nozzle will be provided according to capacity ofnozzle in relevant protected area. In case UMA, after fire happens, using fire alarmsystem by detecting fire automatically, water mist pump shall be runned. And water isdischarged into fire area through nozzle to extinguish it. During spraying water, audibleand visible alarms are provided in the protected space.

Water Mist Skid(Low)

Water Mist Skid(High)

SEAPLU

S for your safety life

Water Mist Controller

Water Mist Controller

Local Operating Box

SEAPLUS for your safety life - 8Page

Page 9: Seaplus Fire Fighting Systems

50 ~ 60

90 ~ 100

1.5 (10.6~11.6LPM)

1.5 (14.2~15.0LPM)

1.5

2.5

0.6

3.0

3.0

8.0

Vertical Downward

Vertical Downward

WorkingPressure (bar)

K-Factor(Flow rate)

Installation (m)Projection

Spacing Min. Height Max. Height

Model : SPF-1

40 ~ 90 1.65 (10.6~44LPM) 4.0 0.6 3.0 Vertical Downward

WorkingPressure (bar)

K-Factor(Flow rate)

Installation (m)Projection

Spacing Min. Height Max. Height

Model : HSN-510

Min. 7.5 4.76 (13LPM)4.0 0.5 17.0

8.0 0.5 5.0 Side Shooting

Vertical DownwardInclined angle

(30~60 form vertical)

WorkingPressure (bar)

K-Factor(Flow rate)

Installation (m)Projection

Spacing Min. Height Max. Height

Model : SPF-3

Celling nozzle

Bilge nozzle

Doorway nozzle

0.46 (3.56LPM)

0.46 (3.56LPM)

0.21 (1.62LPM)

SPF-2

SPF-2

SPF-2D

60

4.0 4.0

3.2 3.2

0.4(tip to tip)

Max. 1.5 below Celling

Bilge plate mounted

Max. 0.3 Above Doorway

2.0

-

-

VerticalDownward

WorkingPressure (bar)ModelNozzle K-Factor

(Flow rate)Installation (m)

ProjectionSpacing Location Max. distance to wall

Model : SPF-2 (Engine Room)

50 ~ 60

90 ~ 100

1.5 (10.6~11.6LPM)

1.5 (14.2~15.0LPM)

1.5

2.5

0.6

3.0

3.0

8.0

Vertical Downward

Vertical Downward

WorkingPressure (bar)

K-Factor(Flow rate)

Installation (m)Projection

Spacing Min. Height Max. Height

Model : SPF-1C (Accomodation)

Local Application System

Total Application System

SEAPLUS for your safety life -9Page

Page 10: Seaplus Fire Fighting Systems

High Expansion Foam Fire extinguishing system

High expansion foam system is used as alternative system of Halon extinguishing system.As halon replacement being phased out due to environmental reasons, high expansion foam system is goodreplacement. It is also excellent alternative system of CO2 and sprinkler systems. High expansion foam system issuitable for installation in engine room together with adjacent spaces as local and /or total flooding. The system ismanually operated but may be supplied upon request with remote operation.

High expansion foam system has been extensively full scale tested for fires in machinery spaces,class 1, 2&3, following IMO guidelines. High expansion foam system

extinguishes fires with a combination of water and foam. Foam fills allthe voids and seals the fire from the air supply, and steam absorbsheat energy when water is vaporized. An inert atmosphere is createdand the fire is extinguished. When a fire occurs, fire fighting canimmediately begin by the user of high expansion foam system and there

is a further advantage of reduced damage due to the cooling effectcreated by the water and the foam on surfaces.

When installing high expansion foam system there is no need for large airducts or unnatural hull opening to produce foam. simplified piping system and low

weight generators in combination with seaplus traditionally and well proven foamcentral unit makes the whole system easy to install.

SEAPLU

Sfor your safety life

High Expansion Foam Generator V : Vertical downward H : Horizontal

SPHG-30

SPHG-60

SPHG-90

32

75

110

16.0

37.5

55.0

4

7

10

>28

>65

>96

0.4JIS10K-25A

Flange

V 880 / H 877

V 877 / H 874

V 874 / H 877

Foam Generator

Model Foam SolutionFlow rate(LPM)

Foam Capacity(m3/min)

WorkingPressure(Mpa)

ExpansionRatio(Times)

ConnectionMethod K-Factor Weight

(kg)

Certification Proportioner

SPECIFICATION1) High Expansion Foam Concentrate : Meteor P +, Skum2) Mixing Ratio : 2% (Foam Concentrate) + 98% (Water)3) High Expansion Foam Generator

SEAPLUS for your safety life - 10Page

Page 11: Seaplus Fire Fighting Systems

Deck Foam Fire extinguishing system

Foam system for the protection of chemical and oil tank decks or heli-decks in accordance with classrequirements and IBC code. Calculated and designed in accordance with international regulations. The foam monitors may be delivered as manually operated (electric or hydraulic type).

Foam Monitor

50F - 100W50F - 150W80F - 200W80F - 250W

3,0006,000

13,00020,000

JIS10K-100AJIS10K-150AJIS10K-200AJIS10K-250A

JIS10K-50AJIS10K-50AJIS10K-80AJIS10K-80A

Model Capacity (LPM) Connection Size

Model Max. Water FlowRate (LPM)

Connection SizeWater Side Foam Side

Foam Tank Unit Balanced Pressure mixer

Foam Proportioner

500 ~ 1,5001,500 ~ 3,0003,000 ~ 5,0005,000 ~ 8,000

FM - 65FM - 80

FM - 100FM - 125

JIS10K-65AJIS10K-80A

JIS10K-100AJIS10K-125A

Foam Hose Box

Foam Monitor

SEAPLUS for your safety life - 11Page

Page 12: Seaplus Fire Fighting Systems

High Pressure CO2 Fire extinguishing system

Carbon Dioxide(CO2) Gas, the fastest and most efficient extinguishing agent against fires in protected spaces,suffocates the fire within designated time and minimize the damage in protected spaces.The Fire Extinguishing System extinguishes the fire by means of CO2 gas. The system consists essentially of CO2cylinders, main isolating valve(s), manifold, CO2 nozzles in compartment protected space, and pipe lines connectingthese main parts. The system is to be designed by the required discharging time, CO2 cylinders quantity and which arestored in a independent CO2 room. For further security in ship's cargo holds, a smoke detection system can becombined with the CO2 system. CO2 gas, the fastest and most efficient extinguishing agent against fires in protectedspaces, suffocates the fire within designated time and minimize the damage in protected spaces.

SEAPLU

Sfor your safety life

Master Control Cabinet

Cylinder Valve

Pressure Operating Distribution Valve(1”~6”)

SEAPLUS for your safety life - 12Page

Page 13: Seaplus Fire Fighting Systems

Low Pressure CO2 Fire extinguishing system

The required quantity of CO2 gas is stored in one or two large tank. The tank unit is furnished with its ownrefrigeration machinery to keep the temperature and also to adjust the pressure at the correct level.The system is designed and installed so that CO2 gas can be discharged into relevant protected area using valvecontrol cabinet. At that moment, the required quantity of CO2 gas is adjusted by timer which is installed at relevantvalve control cabinet.

Pressure CO2 Storage Tank

SEAPLUS for your safety life - 13Page

Instrument Control Panel

Safety Valve 15~25mm(1/2”~1”)

Safety Valve 3~300mm(1/8”~12”)

Double Stop Valve 15~32mm(1/2”~1-1/4”) Refrigerator

Page 14: Seaplus Fire Fighting Systems

Dry Chemical Powder Fire extinguishing system

The SEAPLUS dry powder system is designed specifically for marine application so thatcan be met with SOLAS requirements for LPG and LNG tankers.

SEAPLU

Sfor your safety life

Hose Station Box

SEAPLUS for your safety life - 14Page

10

16

20

25

3.5

10

18

23

30

5 ~ 10

Model Flow Rate (kg/sec) Shooting Length (m)

Hand Hose Gun

Monitor

Dry Chemical Powder Skid

Pneumatic Control CabinetDry Chemical Powder Gun

Page 15: Seaplus Fire Fighting Systems

Automatic Sprinkler Fire extinguishing system

This system is installed in accommodation spaces and other service on the vessels such as passenger ships and carferries. The sprinkler system is the most effective at its early stage in extinguishing fire. Statistics estimates that about 70% of all fires has been extinguishing by less than three sprinkler heads.

Nozzle Escutcheons

SEAPLUS for your safety life - 15Page

Operation of sprinkler-systemImmediately after fire breaks out in a protected area, the intense heat rises rapidly under ceiling zone.As soon as the ambient temperature has reached the set release temperature, the glass bulb bursts and the sprinkleris activated. The sprinkler pressure tank contains fresh water, which being discharged into protected area, at a

constant pressure level. When sprinkler nozzles are actuated,the sprinkler system is activated resulting in a pressure dropin the sprinkler storage tank.Water supply is provided with adequate pressure bydedicated pump set which is arranged to start automaticallywhen the pressure falls down below set point of the pump'sstart-up relay. The sea ensures an inexhaustible supply as fireextinguishing agents, posing no threat to passenger andcrew. For safety reasons, the sprinkler pumps can be operatedform the ship's main and emergency switchboard.

Sprinkler Heads

Sprinkler Nozzle Release

Sprinkler Central Panel

Page 16: Seaplus Fire Fighting Systems

Fire detection Alarm system

The fire detection and alarm system consists of fire detectors, manual call point, controlpanel, repeater and alarm device and so on.Upon the receipt of fire and fault signals, fire alarm system shall send relevant signals toalarm monitoring, alarm device and VDR with audible and visible alarm as well asindicate fire and fault signals on LCD of fire alarm panel with audible alarm.

Heat Detector

SEAPLU

S for your safety life

Flame Detector Manual Call Point

Smoke Detector Isolator

SEAPLUS for your safety life - 16Page

Fire Alarm Control Panet (JB-QB-4508)-4 Loops / 508 Addressable DetectorsFire Alarm Repeater (JB-QB-4508R)Heat DetectorSmoke DetectorInfra Red Type Flame DetectorManual Call PointIsolator

Fire Alarm Controller Fire Alarm Repeater

Page 17: Seaplus Fire Fighting Systems

Fire Man’s Outfit Equipments

SEAPLUS for your safety life - 17Page

Loose Fire Fighting Equipment

Fire Suit Air Breathing Apparatus Fire Axe With Beit and Life Line Safety Lamp

9L Foam 6.8kg CO2 6.5kg Dry PowderFire Extinguisher (Portable Type)

45L Foam 135L Foam Fire Extinguisher (Wheel Type)

Portable FoamApplicator Assembly

Fire Extinguisher

Sea water Fire Fighting Equipments

Fire Hose Rack Fire Hose Box Fire Hose Reel Spanner

International Shore Connection Fire Hose With Coupling Jet / Spray Nozzle

Page 18: Seaplus Fire Fighting Systems

SEAPLUS for your safety life - 18Page

Quality Certification

Page 19: Seaplus Fire Fighting Systems

SEAPLU

S for your safety life

SEAPLUS for your safety life - 19Page

Total Fire Test Shop

ScalesSpecification IMO Circ.668 CLASS III (Above 3,000 m3 for large ship)Length 35 mBreadth 11 mHeight 12 mVolume 3,750 m3

Material Anti-Fire Block & Anti-Fire FoamMajor Zone Division Total Fire Test Area : Machinery Area / Control & Monitoring Room

Control & Monitoring System

Remote Control for : Pump, ValvesMonitoring & Recording Agent Flow & Pressure

F.O. Flow, Pressure & TemperatureTest Shop Atmosphere TemperatureEngine Mock-Up Temperature

O2 Concentration F.O. Spray NozzleTest Shop Atmosphere

Analysis Equipment All Data Analysis SystemData Saving on Computer & Print

What Fi-Fi System can test ? What Kind of fire can test ?

CO2 System Oil Spray Fire High Pressure (150 bar)Low Expansion Foam System Low Pressure (7 bar)High Expansion Foam System Engine Mock-UpDry Chemical Powder System Pool FireWater Mist System Class A FireWater Spray System Cabin, Corridor & Public Space Fire (Future)Smoke Sampling SystemFire Detection SystemSprinkler SystemPortable ExtinguisherOther Water Based Fi-Fi System

Page 20: Seaplus Fire Fighting Systems

WORLD WIDE A/S NET WORKSEAPLUS makes the future with the challenge to a new world and unswerving R & D efforts. You shall be assured of our efforts for the world-highest precision and quality.

VIKING LIFE-SAVING EQUIPMENT A/S (HEAD OFFICE)Saedding Ringvej 13 6710 Esbjerg V DenmarkCONTACT : Mr. Jan Nikolaj Jensen

TEL : +45 76 118100, FAX : +45 76 118101

[ SEAPLUS share the following world-wide service station with VIKING A/S]

USA - Miami, California, Cape Canaveral, WashingtonFRANCE - Montivilliers, VitrillesNORWAY - Straume, Oslo, Avladsnes, AlesundTURKEY - Tuzla/IstanbulFINLAND - LietoRUSSIA - PetersburgSWEDEN - StockholmESTONIA - TallinnUAE - DubaiSPAIN - Cadiz, Puxeiros-Mos-Vigo, BarcelonaSOUTH AFRICA - Cape Town, DurbanICELAND - HafnafjordurNETHERLANDS - LX Zwijndrecht, El Harlem, DelfzijlBELGIUM - LokerenITALY - Napoli, La Spezia, MessinaSINGAPOREMALAYSIA - Johor Darul TakzimDENMARK - Esbjerg GERMANY - Hamburg, BremerhavenHONG KONG - Kwai Chung, N.T.

SEAPLUS for your safety life - 20Page

Page 21: Seaplus Fire Fighting Systems

SINGAPORE W.H BRENNAN & CO PTE. LTD.47 Loyang Way, Singapore 508739CONTACT : Mr. Desmond Goh TEL : +65 6549 5111, FAX : +65 6542 5246E-MAIL : [email protected]

GERMANYMK-MARINE GMBHWerner Oltersdorf Westkai 50, D-27572, Bremerhaven, GermanyCONTACT : Mr. Werner OltersdorfTEL : +49 471 97227 13, FAX : +49 471 97227 27E-MAIL : [email protected]

FIREFLYAm Redder 122941 Bargteheide, GermanyCONTACT : Mr. Merijn StruijsTEL : +49 (0) 4352 20 48 911, FAX : +49 (0) 4352 20 48 920E-MAIL : [email protected]

NETHERLANDMK-MARINE GMBHInglasco Fire System B.V, Gounderakstraat 22,307 DB Rotterdam, NetherlandsCONTACT : Mr. John FongersTEL : +31 10 479 3611, FAX : +31 10 479 2355E-MAIL : [email protected]

U.A.E MAXELL INTERNATIONAL L.L.CP.O BOX 47620, DUBAI, U.A.ECONTACT : Mr. N.S. PAI TEL : +971 4 2676128, FAX : +971 4 2676129E-MAIL : [email protected]

TURKEY GANI SHIP SPARE LTDGumussuyu Mah, Kutlu Sok. No. 834437 Taksim Istanbul, TurkeyCONTACT : Ms. Sinem SANDIKCITEL : +90 212 293 4477, FAX : +90 212 293 4478E-MAIL : [email protected]

CHINAOCEAN MARINE SERVICE CO., LTDNo. 1100 Wuzhong Road, Minhang Qi, Shanghai, ChinaCONTACT : Mr. J.G.Choi TEL : +86 21 5422 4157, FAX : +86 21 5422 4156E-MAIL : [email protected]

HAI CHEUNG TRADING CO. (HK) LTDShanghai Representative office8/F, Ju Yang Tower, No. 1200 Pudong Avenue, Shanghai,China, 200135CONTACT : Mr. Gus HouTEL : +86 21 6888 9889, FAX : +86 21 6329 3888E-MAIL : [email protected]

JAPANPRO-TECH Co.,Ltd.1-6, Taisho-cho 6-Chome, 1 mabari, Ehime, 794-0025, JapanCONTACT : Mr. Hiroki KumazawaTEL : +81 898 23 2051, FAX : +81 898 23 2078E-Mail : [email protected]

TAIWAN PILOT MARINE TECHNOLOGY &ENGINEERING CO.,LTD.No.217, Hsing Sheng Road, Chuan Cheng Dist. Kaohsiung,Taiwan. R.O.C. CONTACT : Mr. Johny Wan TEL : +886 7 8211545, FAX : +866 7 8211571E-MAIL : [email protected]

SEAPLUS for your safety life - 21Page

G o w i t h SEAPLUS f o r y o u r s a f e t y o f f i r e e x t i n g u i s h i n h s y s t e m s , e g u i p m e n t s , a n d o t h e r s

Page 22: Seaplus Fire Fighting Systems

SEAPLU

S Plant Project Team Plant Project Team

SEAPLUS for your safety life -22Page

FIRE FIGHTING SYSTEM- CO2 SYSTEM- DRY CHEMICAL SYSTEM- WATER SPRAY SYSTEM- CLEAN AGENT SYSTEM- SPRINKLER SYSTEM- WATER SPRAY SYSTEM- FOAM SYSTEM- HYDRANT SYSTEM

FIRE ALARM & FIRE DETECTION SYSTEM KDX-III DELUGE & SPRINKLER SYSTEM

DESIGN & CONSTRUCTION for FIRE FIGHTING SYSTEM of PLANT PROJECTSeaplus’s Plant project team consists of specialists for mechanics, electronics, thermodynamicsand fluid mechanics based fire fighting system.Plant project team has delivered to all Korean thermal power plant a fire fighting system & firealarm and fire detection system for parts of bulk material handling system and boiler system after2003 year. We have licenses for fire fighting design and construction approved by Koreangovernment. We accepted an order for the fire fighting system of Cuba DPP project and the service gas supplysystem of Bahrain IWPP project recently.

Page 23: Seaplus Fire Fighting Systems

SEAPLUS for your safety life - 23Page

PLUS GUN DUST SUPPRESSION SYSTEM

WATER SPRAY SYSTEMWater spray system is designed to direct water at a required density, from nozzles having predetermined patterns tocompletely impinge water onto the hazard surface being protected. It is designed for use in a variety of specialhazards applications including flammable and combustible liquid hazards, transformers and turbines.

SERIVCE GAS SUPPLY SYSTEMService gas system applied to steam power generator. Nitrogen (N2) gas system shall be to blanket the steam andwater line in order to prevent corrosion during long term wet lay up. Carbon Dioxide (CO2) gas system is used forpurging the air and other gases in pipe system. Hydrogen (H2) gas system is used as a coolant for the main steamturbine or generators.

Seaplus plant project team plans, designs, manufactures and supplies a full range of proprietary products for dustsuppression, return belt washing and water spray system. Plusgun dust suppression system consists of the PLC basedcontrol system and a shooting gun which spray water on the ground uniformly. Plus dust suppression system isfocused on developing intelligent solutions for the flying ash at raw material storage area like as coal, coke and scrapiron etc or inside chute and skirt in transfer tower. Return belt washing system for protect to stack a raw material onthe floor in gallery or girder is applied to bulk material handling system.

PLC BASED CONTROL SYSTEM

Page 24: Seaplus Fire Fighting Systems

ADD 1575-3, SongJeong-Dong GangSeo-gu Busan KoreaTEL +82-51-831-0119FAX +82-51-831-1119E-mail Domestic /[email protected]

Overseas /[email protected] /[email protected]/S /[email protected]

http://www.sea-plus.co.kr

Rev. No. 200905 Vol. 1