OBJECTIVE

To demonstrate how the M-I PC Scale Dissolver Range can assist in

restoring well productivity impaired by scale deposition

Page 2: Scale Dissolution

AgendaAgenda

• M-I Swaco Organisation

• Calcium Carbonate dissolvers

• Sulphate dissolvers

• Case history – well stimulation

Page 3: Scale Dissolution

M-I Swaco OrganisationM-I Swaco Organisation

• M-I Swaco 60:40 JV company of Smith & Schlumberger

• Global market leaders in Drilling, Completion Fluids & Waste Management

• World Class Technology, Support & Logistics delivering value to customer

Integrated Fluids

Engineering

Integrated Fluids

EngineeringDrilling FluidsDrilling Fluids

Completion Fluids

Completion Fluids

Drilling Waste Management

Drilling Waste Management

Federal Wholesale &

Industrial

Federal Wholesale &

Industrial

PRODUCTION CHEMICALS

PRODUCTION CHEMICALS

Production Chemicals provides ‘Cradle to Grave’ portfolio

Page 4: Scale Dissolution

Engineering & Technical Support Engineering & Technical Support LeadershipLeadership

• World Class experienced and trained engineers

• Proprietary software packages to optimise drilling, production and environmental performance

• Research centres, technical support operations strategically located worldwide

• Leader in developing drilling fluids, production chemicals and waste management technologies that deliver value-added performance with environmental acceptability

Page 5: Scale Dissolution

Technology FocusTechnology Focus

• Commitment to R&D- Significant reinvestment of

revenues in R&D programs

• Strong focus on joint customer research efforts- Develop practical, fit-for-market

technologies - Shorten development cycles

• Schlumberger offers M-I world’s most comprehensive reservoir expertise- Opportunity to generate

technologies that complement “fluid and production chemicals disciplines”

Page 6: Scale Dissolution

World Class Infrastructure, Distribution & World Class Infrastructure, Distribution & LogisticsLogistics

• Integrated procurement, manufacturing, inventory management and transportation system

• Blending and storage facilities in close proximity to customers

• Comprehensive network of centralised warehouses and dock facilities

• Exclusive deepwater port participation

Page 7: Scale Dissolution

Global Service OrganisationGlobal Service Organisation

Page 8: Scale Dissolution

M-I Production ChemicalsM-I Production Chemicals

Corporate Capabilities

Page 9: Scale Dissolution

Health Safety and EnvironmentHealth Safety and Environment

• Health and Safety is our first priority

• Operating to ISO 9001/2000 and ISO 14001 standards

• In-house ecotoxicology laboratory operating to GLP. Capable of performing all OSPARCOM approved tests

• R & D focus on more environmentally friendly chemistry

• Environmental management capability

Page 10: Scale Dissolution

• Corrosion Inhibitors

• Scale Inhibitors / Dissolvers

• Bactericides

• Demulsifiers

• Wax Inhibitors

• Water Treating Chemicals

• Antifoams

• Hydrate Inhibitors

• Hydrogen Sulphide Scavengers

• Drag Reducers/Flow Improvers

• Cleaning Compounds

• Commodities

Comprehensive Product OfferingComprehensive Product Offering

Page 11: Scale Dissolution

Research & TechnologyResearch & Technology

• 30% of technical professionals are lab-based

• Main laboratories in Bergen, Aberdeen, Dubai and Perth

• Long-term, client focused projects oriented toward novel chemistries

• Emphasis on more environmentally friendly chemistry- In-house ecotoxicology

laboratory

Page 12: Scale Dissolution

Scale DissolversScale Dissolvers

Page 13: Scale Dissolution

Mineral Scale Dissolution

Carbonate scale - CAL-Acid

Barium/Strontium Sulphate scale - BaSOL

Calcium Sulphate - Gypsol

Iron Sulphide - Pyrisol

Iron deposits/rust - R-Sol

MIPC Scale Dissolver Product LineMIPC Scale Dissolver Product Line

Page 14: Scale Dissolution

What is Scale?What is Scale?

• An adherent mineral deposit precipitated from solution

• Commonly found in conjunction with other fouling deposits- e.g. iron hydroxides and

sulphides, waxes, asphaltenes, etc..

• Once deposited, crystal growth can lead to the development of severe scaling problems

• Mineral scale deposition cuts oil production by plugging payzones and blocking tubing and topsides.

Page 15: Scale Dissolution

Causes of ScaleCauses of Scale

• The causes of scale and fouling deposits are many, varied and complex

• Oilfield waters contain a large number of potential scaling species

• These include soluble ions such as calcium, magnesium, barium, etc which precipitate when they encounter changes in water conditions- e.g. temperature, pH, concentration effects and

incompatibilities

• In addition, corrosion by-products, process contaminants and incompatible chemical treatments lead to fouling and scaling

Page 16: Scale Dissolution

Types of ScaleTypes of Scale

Scaling speciesScaling species

CaCO3CaCO3

FeO/OHFeO/OHFeCO3FeCO3

FeSFeS

BaSO4BaSO4SrSO4SrSO4

CaSO4CaSO4

Acid soluble scales

Acid insoluble scales

Page 17: Scale Dissolution

Scale RemovalScale Removal

CaCO3 + 2HCl CaCl2 + CO2 + H2O

BaSO4 + AEDTA BaEDTA + ASO4

(A - alkali metal)

Acid soluble scales

• Scale removed through reaction to generate new chemical species

Acid insoluble scales

• Much harder scale type to remove. Requires chelation chemistry

Page 18: Scale Dissolution

Calcium Carbonate DissolutionCalcium Carbonate Dissolution

Page 19: Scale Dissolution

Carbonate Scale DissolvingCarbonate Scale Dissolving

Ca2+ + CO3 CaCO3

Ca2+ + 2(HCO3) CaCO3 + CO2 + H2O

• Most common scale type found in oilfield production systems..

Calcium Carbonate• Formed by the combination of the calcium ion with either

carbonate or bicarbonate in water

Page 20: Scale Dissolution

Carbonate Scale – Deposition FactorsCarbonate Scale – Deposition Factors

pH

Increasing alkalinity leads to carbonate scale deposition

Pressure

Pressure drops lead to CaCO3 deposition, hence deposits at valve locations

Temperature

CaCO3 solubility decreases with increasing temperature

Page 21: Scale Dissolution

Carbonate Scale RemovalCarbonate Scale Removal

• Traditionally performed with Hydrochloric acid- Very reactive – quick dissolution time- Cheap- Readily available

• BUT……- Very corrosive- Hazardous- ‘Secondary’ scaling can occur- Possibility of formation damage

Page 22: Scale Dissolution

MIPC CAL-AcidMIPC CAL-Acid

• Developed as a viable alternative to HCl

• Low corrosivity

• ‘Sequesters’ scaling ions

• Loading capacity comparable to HCl

• Slower to react, but…- Allows better reaction control in contacting critical scale- Penetrates deeper into affected reservoir areas

Page 23: Scale Dissolution

MIPC CAL-AcidMIPC CAL-Acid

• Affords rapid, yet controlled reaction

• Loading capacity – 260 g/ltr (neat product)

• Typically applied as 50% solution- Maximises performance vs. concentration effects

• Inherent sequestering capacity ensures prevention of ‘secondary scaling’

Page 24: Scale Dissolution

Carbonate Dissolvers ComparedCarbonate Dissolvers Compared

0

10

20

30

40

50

60

70

80

90

100

% S

cale

dis

solv

ed

0 1 2 3 4 5 6Time (Hours)

Dissolution of Calcium Carbonateat 60 deg C, static, 260g/ltr CaCO3

EDTA

CAL-acid

15% HCl

Page 25: Scale Dissolution

Secondary ScalingSecondary Scaling

• Mineral acids liberate calcium and iron which can re-precipitate during the treatment

This can lead to formation damage

• MIPC CAL-Acid has an inherent sequestering capacity

• Scaling ions released by acid treatment are sequestered and held in solution

• No expensive additives are necessary!!

Page 26: Scale Dissolution

Corrosivity of MIPC CAL-AcidCorrosivity of MIPC CAL-Acid

• Mineral acids very corrosive – potential for tubular damage

• Central to low corrosivity of CAL-Acid is corrosion inhibitor package- Stable to 100oC

• Corrosivity against L80 & 13Cr steel presented

Page 27: Scale Dissolution

Corrosivity of MIPC CAL-AcidCorrosivity of MIPC CAL-Acid

0

10000

20000

30000

40000

50000

60000

70000

80000

90000

Cor

rosi

on r

ate

(mpy

)

4 8 24

Time (Hours)

Corrosion of L80 Steel100 deg C, static

CAL-acid 100% CAL-acid (uninhib) 15% HCl

0

10000

20000

30000

40000

50000

60000

70000

80000

90000

Cor

rosi

on r

ate

(mpy

)

4 8 24

Time (Hours)

Corrosion of 13Chrome Steel100 deg C, static

CAL-acid 100% CAL-acid (uninhib) 15% HCl

Page 28: Scale Dissolution

MIPC CAL-AcidMIPC CAL-Acid

Advantages

• Low corrosivity

• ‘Sequesters’ scaling ions

• Load capacity similar to HCl

• Better reaction control in contacting critical scale

• Penetrates deeper into affected reservoir areas

Disadvantages

• Longer contact time

Page 29: Scale Dissolution

Barium Sulphate DissolutionBarium Sulphate Dissolution

Page 30: Scale Dissolution

Sulphate Scale DissolutionSulphate Scale Dissolution

• Sulphate scales of barium, strontium and calcium present a complex dissolution problem

• Characteristics- Insoluble in acid- Very low solubility in

water- Forms hard,

consolidated scales- Usually found as ‘mixed’

scale deposit

Page 31: Scale Dissolution

Barium SulphateBarium Sulphate

• Least soluble scale found in oilfield systems- 2.3 mg/l at 25oC

• Many formation waters contain high barium concentrations

• Not usually a problem until seawater breakthrough- High SO4 levels

Barite - naturally occurring BaSO4

Page 32: Scale Dissolution

Barium Sulphate Scale RemovalBarium Sulphate Scale Removal

• Low solubility yields a difficult dissolution problem

• Acid insoluble, thus we must employ a different chemical approach…....CHELATION

• Chelating agents complex with metal ions to return water soluble species - increasing solubility - e.g. EDTA - Ethylene Diamine Tetra-acetic Acid

Page 33: Scale Dissolution

Chelation ProcessChelation Process

• Divalent metal ions can form stable complexes with chelating agents

• Even with low solubility, barium ions solvate in water

BaSO4 Ba+ + SO42-

• Addition of a chelating agent (L) gives

Ba2+ + L BaL

• Effectively “removing” barium ions from solution

BaSO4 + L BaL + SO42-

• Driving solvation of more barium ions and thus scale

Page 34: Scale Dissolution

Dissolver FormulationDissolver Formulation

• Sulphate scale still has a low solubility even in the presence of some chelating agents

• To deliver effective dissolver chemistry we need to consider...

Chelation Conversion Catalysis

Sulphate scale dissolver

Page 35: Scale Dissolution

Dissolver FormulationDissolver Formulation

• Chelation- Must have high metal affinity – log K1

- Operate at optimum pH

• Conversion- Conversion agents assist in metal ion chelation eg

• Catalysis- Enables dissolution process to proceed more efficiently

Fe (II) Fe (III)

Favours chelation of ferric rather than ferrous ions

Page 36: Scale Dissolution

BaSOL and BaSOL 2000BaSOL and BaSOL 2000

Latest advance in the field of barium sulphate dissolution

Delivers optimum pH conditions for scale dissolution

Non-corrosive

Non-hazardous for handling

Affords rapid dissolution rates

High loading capacity - 120g/ltr possible

Page 37: Scale Dissolution

Relative Dissolution RateRelative Dissolution Rate

00.5

1.52.5

612

0

10

20

30

40

50

60

70

80

90

100S

cale

rem

aini

ng (

%)

Time (hours)

Relative dissolution rate of BaSOL and EDTA Barium sulphate, 85 deg C, 4% w/v

BaSOL

EDTA

Page 38: Scale Dissolution

Temperature EffectsTemperature Effects

0 0.5 1 1.5 2 2.5 3 4 6 10 12

120C

100C

80C

60C40C

20C

0

10

20

30

40

50

60

70

80

90

100S

cale

rem

aini

ng (

%)

Time (hours)

Dissolution of oilfield scale as a function of tem peratureBaSOL 5%w/v

Page 39: Scale Dissolution

WettabilityWettability

0 1 2 3 4 5 6 7 8 9 10

0

10

20

30

40

50

60

70

80

90

100

% S

cale

rem

aini

ng

Time (hours)

Dissolution of barium sulphate scale as a function of wettability80 deg C, static conditions

Water w et

Crude w et

Asphaltene w et

Page 40: Scale Dissolution

Progress in Barium Sulphate DissolutionProgress in Barium Sulphate Dissolution

Sequestering capacity in g/ltr @ 6 hrs @ 90oC

Analar BaSO4 Field scale Comments

High low Multi-stage

20 12 Very slow

30 30 Slow

40 80 Fast

120 120 Best so far

Converter + acid

EDTA

DTPA

BaSOL

BaSOL 2000

Page 41: Scale Dissolution

Calcium Sulphate DissolutionCalcium Sulphate Dissolution

Page 42: Scale Dissolution

Calcium SulphateCalcium Sulphate

• Formed in a similar way to Barium and Strontium Sulphates

• Often found as a co-deposit with Barium & Strontium

• Removal assured with chelation chemistry

Gypsum - naturally occurring CaSO4

Page 43: Scale Dissolution

MIPC GypsolMIPC Gypsol

• Gypsol dissolves calcium sulphate at ~2.8 times the speed of BaSOL

• Designed specifically for Calcium sulphate scale

• Outperforms EDTA - traditional calcium sulphate dissolver

• Non- corrosive

• Supplied as a pH 7-8 solution, thus low handling hazard

Page 44: Scale Dissolution

Comparative DissolutionComparative Dissolution

0

20

40

60

80

100%

Cal

cium

Sul

phat

e re

mai

ning

0 0.5 1 1.5 2

Time (Hours)

Calcium sulphate dissolution[100 deg c, static conditions]

EDTA Gypsol

Page 45: Scale Dissolution

Temperature EffectsTemperature Effects

0 1 2 3 4 5 6 7

0

20

40

60

80

100%

Sca

le R

emai

ning

Time (hours)

Dissolution of Anhydrite scale

147 deg

95 deg

60 deg

Page 46: Scale Dissolution

Sulphate Scale Dissolvers - SummarySulphate Scale Dissolvers - Summary

BaSOL 2000

•Rapid dissolution rates

•High load capacity

•Non corrosive

•Safe to handle

Best Barium/Strontium sulphate de-scaling

solution

Gypsol

•Outperforms EDTA

•Non corrosive

Designed specifically for the removal of calcium

sulphate

Page 47: Scale Dissolution

BaSOL Scale DissolverBaSOL Scale Dissolver

CASE HISTORYCASE HISTORY

Page 48: Scale Dissolution

Case History – BaSOL Sulphate DissolverCase History – BaSOL Sulphate Dissolver

• North Sea well with severe decline in production- Sulphate scale across

perfs

• Tail pipe scale preventing access to perforating guns

• Scale analysis- 72% BaSO4

- 25% SrSO4

- 3% CaCO3

Page 49: Scale Dissolution

BaSOL Case History – Treatment BaSOL Case History – Treatment SummarySummary

• Bullhead application used

• Spearhead with KCl brine with demulsifiers

• Spot dissolver & allow to reach formation temperature

• Series of displacement & soak sequences- Maximise dissolution

• Total of 5 dissolver sequences carried out- First two across perforations- Last three in tailpipe- PI noted after each flowback

Page 50: Scale Dissolution

BaSOL Case History - ResultsBaSOL Case History - Results

• Production increased from 350 m3/day to 1975 m3/day- 464% increase over 5 treatments

• Total mass of 500 kg sulphate scale removed- 233.2 kg BaSO4

- 266.4 kg SrSO4

• 53 kg sulphate scale removed from perforations/near well bore- Represents greatest detrimental affect on production

• Success meant that well did not need re-perforation

- Represents added value benefit

Page 51: Scale Dissolution

BaSOL Case History - ResultsBaSOL Case History - Results

Dissolver sequence

Kg BaSO4 removed

Kg SrSO4 removed

Production rate

(m3/day)

Dissolver target zone

0 - - 350 -

1 20 19.5 1390 Perfs

2 4.5 9.1 1560 Perfs

3 100.9 110.9 1755 Tail Pipe

4 93.2 82.9 1800 Tail Pipe

5 14.6 44.0 1975 Well Bore

Page 52: Scale Dissolution

BaSOL Case History – Production ProfileBaSOL Case History – Production Profile

Production increase - Post Treatments

350

13901560

1755 18001975

0

500

1000

1500

2000

2500

0 1 2 3 4 5

Dissolver sequence

Pro

duct

ion r

ate

(m

3/d

ay)

Production Rate (M3/ day)

Page 53: Scale Dissolution

BaSOL Case History – Scale Removal BaSOL Case History – Scale Removal ProfileProfile

0

20

40

60

80

100

120

0 1 2 3 4 5

Dissolver sequence

BaSO4 removed (kg)

0

20

40

60

80

100

120

0 1 2 3 4 5

Dissolver sequence

SrSO4 removed (kg)

Page 54: Scale Dissolution

SummarySummary

Page 55: Scale Dissolution

SummarySummary

• The MIPC range of Scale Dissolvers represent leading edge technology in the market place- CAL-Acid for carbonate scales- BaSOL 2000 for barium & strontium sulphates- Gypsol for calcium sulphate

• Field experience in removal of barium & strontium sulphate scales from tubulars and formations- Significant increase in productivity

• Personnel in China with experience in scale dissolver and scale inhibitor squeeze treatments

Page 56: Scale Dissolution

M-I Production Chemicals has the chemical resourcesto remove any commonly encountered field scale

MIPC Expertise Innovative range

COMPREHENSIVE SCALE CONTROL PACKAGECOMPREHENSIVE SCALE CONTROL PACKAGE

Page 57: Scale Dissolution

MIPC Scale Dissolver Product LineMIPC Scale Dissolver Product Line

Mineral Scale Dissolution

Carbonate scale - CAL-Acid

Barium/Strontium Sulphate scale - BaSOL

Calcium Sulphate - Gypsol

Iron Sulphide - Pyrisol

Iron deposits/rust - R-Sol