STRUCTURAL NOTES A. BUILDING CODE 1. THE STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE 2012 VIRGINIA UNIFORM STATEWIDE BUILDING CODE WITH LOCAL AMENDMENTS. B. GENERAL 1. FOR LOADING CRITERIA SEE ADJACENT TABLE. 2. THE STRUCTURE HAS BEEN DESIGNED TO WITHSTAND THE WIND PRESSURES SPECIFIED IN SECTION 1609.0 OF THE INTERNATIONAL BUILDING CODE. SEE THE ATTACHED LOAD TABLE. 3. THE STRUCTURE HAS BEEN DESIGNED TO WITHSTAND THE SNOW LOADS SPECIFIED IN SECTION 1608.0 OF THE INTERNATIONAL BUILDING CODE AND SECTION 7 OF ASCE 7. SEE THE ATTACHED DESIGN DATA TABLE ON THIS SHEET. 4. IN ADDITION TO THE FLAT ROOF SNOW LOAD STATED ABOVE, A SNOW LOAD PROVISION FOR DRIFTING SNOW HAS BEEN PROVIDED IN ACCORDANCE WITH THE REQUIREMENTS OF ASCE 7, SECTIONS 7.7 AND 7.8. 5. THE STRUCTURE HAS BEEN DESIGNED TO WITHSTAND THE SEISMIC FORCES SPECIFIED IN SECTION 1613.0 OF THE INTERNATIONAL BUILDING CODE. SEE THE SEISMIC DESIGN LOAD AND DATA TABLE ON THIS SHEET. 6. METHODS, PROCEDURES, AND SEQUENCES OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO MAINTAIN AND INSURE THE INTEGRITY OF THE STRUCTURE AT ALL STAGES OF CONSTRUCTION. 7. CONTRACTOR MUST FABRICATE AND ERECT STEEL IN ACCORDANCE WITH OSHA'S SAFETY REQUIREMENTS, 29 CFR PART 1926 SAFETY STANDARDS FOR STEEL ERECTION; FINAL RULE. 8. STRUCTURAL MEMBERS HAVE BEEN LOCATED AND DESIGNED TO ACCOMMODATE THE MECHANICAL EQUIPMENT AND OPENINGS SPECIFIED BY THE MECHANICAL CONSULTANT. ANY SUBSTITUTIONS RESULTING IN REVISIONS TO THE STRUCTURE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE STRUCTURAL ENGINEER. 9. THE GENERAL CONTRACTOR AND SUB(CONTRACTORS SHALL DETERMINE THE SCOPE OF THE STRUCTURAL WORK FROM THE CONTRACT DOCUMENTS TAKEN AS A WHOLE. THE STRUCTURAL DRAWINGS SHALL NOT BE CONSIDERED SEPARATELY FOR PURPOSES OF BIDDING THE STRUCTURAL WORK. DUE CONSIDERATION SHALL BE GIVEN TO OTHER STRUCTURAL WORK OR WORK RELATED TO THE STRUCTURE, INCLUDING NECESSARY COORDINATION DESCRIBED OR IMPLIED BY THE ARCHITECTURAL AND MECHANICAL DRAWINGS. 10. WRITTEN PERMISSION MUST BE OBTAINED FROM BEI STRUCTURAL ENGINEERS, INC., PRIOR TO THE REPRODUCTIVE USE OF THE STRUCTURAL CONTRACT DOCUMENTS IN ANY FASHION AS STRUCTURAL SHOP DRAWING DOCUMENTS. 11. SCALES NOTED ON THE DRAWINGS ARE FOR GENERAL INFORMATION ONLY. NO DIMENSIONAL INFORMATION SHALL BE OBTAINED BY DIRECT SCALING OF THE DRAWINGS. 12. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF ALL RESULTING REVISIONS TO THE STRUCTURAL SYSTEM AS A RESULT OF ACCEPTANCE OF CONTRACTOR PROPOSED ALTERNATIVES OR SUBSTITUTIONS. 13. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR FITTING NEW WORK WITH EXISTING CONSTRUCTION. INFORMATION ON EXISTING BUILDINGS SHOWN IN THESE DRAWINGS WAS BASED UPON THE INFORMATION SUPPLIED TO THE STRUCTURAL ENGINEER. THIS INFORMATION IS NOT AS(BUILT DATA AND THE ACTUAL AS(BUILT CONSTRUCTION MAY DIFFER FROM THAT REPRESENTED IN THE DRAWINGS. CONTRACTOR SHALL VERIFY ALL INFORMATION. VARIATIONS FROM THE DIMENSIONS INDICATED ON THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND/OR THE STRUCTURAL ENGINEER. 14. SHORING OF THE EXISTING STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PROVIDE TEMPORARY SHORING WHERE MODIFICATIONS/ALTERATIONS TO EXISTING STRUCTURE IS REQUIRED. THE SHORING DRAWINGS/CALCULATIONS SHALL BE SIGNED AND STAMPED BY A REGISTERED STRUCTURAL ENGINEER IN THE STATE OF JURISDICTION AND SUBMITTED FOR APPROVAL PRIOR TO START OF DEMO WORK. 15. PRINCIPAL OPENINGS IN THE STRUCTURE ARE INDICATED ON THE CONTRACT DOCUMENTS. REFER TO THE ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR SLEEVES, CURBS, INSERTS, ETC. NOT HEREIN INDICATED. OPENINGS IN SLABS WITH A MAXIMUM SIDE DIMENSION OR DIAMETER OF 12 INCHES OR LESS SHALL NOT REQUIRE ADDITIONAL FRAMING OR REINFORCEMENT, UNLESS NOTED OTHERWISE. THE LOCATION OF SLEEVES OR OPENINGS IN STRUCTURAL MEMBERS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW. 16. ALL NON(PRIMARY STRUCTURAL ELEMENTS SUCH AS STAIRS, RAILINGS, LADDERS, METAL STUDS, STOREFRONTS, MULLIONS, ETC. SHALL BE DESIGNED BY A REGISTERED ENGINEER TO MEET THE MINIMUM REQUIREMENTS OF THE LOCAL BUILDING CODES. SUBMIT CALCULATIONS AND SHOP DRAWINGS WITH A SIGNED SEAL OF THE RESPONSIBLE REGISTERED ENGINEER FOR THE LOCAL JURISDICTION. C. FOUNDATION AND SLAB ON GRADE 1. SOIL BEARING VALUE ASSUMED TO BE 1500 PSF FOR FOOTINGS FOUNDED ON UNDISTURBED NATURAL SOIL OR CONTROLLED STRUCTURAL FILL IN ACCORDANCE WITH SUBSURFACE INVESTIGATION AND GEOTECHNICAL ENGINEERING REPORT . SOIL BEARING CAPACITY SHALL BE FIELD VERIFIED BY A SOILS ENGINEER REGISTERED IN THE STATE OF JURISDICTION. 2. BOTTOMS OF ALL FOOTINGS SHALL EXTEND A MINIMUM OF ONE FOOT INTO UNDISTURBED SOIL OR CONTROLLED COMPACTED FILL AND WHERE SUBJECT TO FROST ACTION, AT LEAST TWO FEET SIX INCHES BELOW FINISHED GRADE. ELEVATIONS SHOWN ARE TO TOPS OF FOOTINGS, AND ARE FOR ESTIMATING PURPOSES ONLY. FOOTING ELEVATIONS SHALL BE ADJUSTED AS REQUIRED TO SUIT FIELD CONDITIONS. BORING LOGS ARE ON FILE AT THE ARCHITECT'S OFFICE FOR REVIEW BY THE CONTRACTOR. ALL FOUNDATION WORK TO BE DONE IN STRICT ACCORDANCE WITH THE GEOTECHNICAL REPORT AND BE INSPECTED AND APPROVED BY A SOILS ENGINEER PRIOR TO POURING CONCRETE. ALL CONTROLLED COMPACTED FILL SHALL BE PLACED UNDER THE SUPERVISION OF A SOILS ENGINEER. 3. THE FOUNDATION FOR THE STRUCTURE HAS BEEN DESIGNED FOR THE FOLLOWING LATERAL EARTH PRESSURES: CANTILEVER RETAINING WALLS 65 PCF 4. EXCAVATIONS FOR SPREAD FOOTINGS, COMBINED FOOTINGS, CONTINUOUS FOOTINGS AND/OR MAT FOUNDATIONS SHALL BE CLEANED AND HAND TAMPED TO A UNIFORM SURFACE. FOOTING EXCAVATIONS SHALL HAVE THE SIDES AND BOTTOMS TEMPORARILY LINED WITH 6 MIL VISQUEEN IF PLACEMENT OF CONCRETE DOES NOT OCCUR WITHIN 24 HOURS OF THE EXCAVATION OF THE FOOTING. 5. FOUNDATION CONDITIONS NOTED DURING CONSTRUCTION, WHICH DIFFER FROM THOSE DESCRIBED IN THE GEOTECHNICAL REPORT SHALL BE REPORTED TO THE ARCHITECT, STRUCTURAL ENGINEER AND GEOTECHNICAL ENGINEER BEFORE FURTHER CONSTRUCTION IS ATTEMPTED. 6. REINFORCEMENT PLACEMENT SEQUENCE FOR FOOTINGS IS NOTED ONLY FOR MAJOR REINFORCEMENT BAR LAYERS. IN SPREAD FOOTINGS AND MATS THE CONTRACTOR SHALL SEQUENCE ALL OTHER BAR PLACEMENTS AS REQUIRED TO CONFORM TO THE CONTRACT DOCUMENTS. 7. WALLS RETAINING BACKFILL HAVE BEEN DESIGNED FOR IN SERVICE LOADS ONLY. THE CONTRACTOR SHALL PROVIDE TEMPORARY SHORING DURING CONSTRUCTION. THE SHORING SHALL NOT BE REMOVED UNTIL THE SUPPORTING ELEMENTS ARE IN PLACE, THE CONCRETE IN THE WALLS AND SUPPORTING ELEMENTS HAS ATTAINED THE SPECIFIED 28 DAY COMPRESSIVE STRENGTH (FC') AND COMPACTION OF THE BACKFILL HAS BEEN COMPLETED. 8. RETAINING WALLS AND/OR EXPOSED CONCRETE WALLS SHALL HAVE CONTROL JOINTS AT 10 FEET AND EXPANSION JOINTS AT 30 FEET MAXIMUM ON CENTERS UNLESS NOTED OTHERWISE. WALLS WITH INTEGRAL COLUMN PIERS OR PILASTERS SHALL HAVE A FORMED CONTROL JOINT ON ONE SIDE OF EACH PIER ON THE EXPOSED FACE OF THE WALL. JOINTS SHALL BE FILLED WITH AN APPROVED SEALANT. 9. EXCEPT WHERE OTHERWISE NOTED, SHALL BE 4" THICK CONCRETE REINFORCED WITH 6X6 W1.4XW1.4WELDED WIRE FABRIC. LAP MESH 6" IN EACH DIRECTION. PLACING, LAP, ETC. TO CONFORM TO WRI STANDARDS. SLAB ON GRADE SHALL BE UNDERLAID BY A MINIMUM OF 4 INCHES OF GRANULAR MATERIAL HAVING A MAXIMUM AGGREGATE SIZE OF 1.5 INCHES AND NOT MORE THAN 10% OF MATERIAL PASSING THROUGH A NO. 4 SIEVE. PRIOR TO PLACING THE GRANULAR MATERIAL, THE FLOOR SUBGRADE SHALL BE PROPERLY COMPACTED, PROOFROLLED, FREE OF STANDING WATER, MUD AND FROZEN SOIL. BEFORE PLACEMENT OF THE CONCRETE, A 10 MIL POLYETHYLENE VAPOR BARRIER SHALL BE PLACED ON TOP OF THE GRANULAR MATERIAL. FOR ALL EXTERIOR SLABS ON GRADE, AIR ENTRAINED CEMENT WITH ENTRAINED AIR OF 6%±1.5% OR EQUIVALENT AIR ENTRAINING AGENT SHALL BE USED. PROVIDE 1/2" PERIMETER EXPANSION JOINT FILLED WITH COMPRESSIVE MATERIAL WHERE SLABS ABUT VERTICAL SURFACES. 10. SLABS ON GRADE SHALL HAVE CONSTRUCTION JOINTS OR CRACK CONTROL JOINTS AT EACH COLUMN LINE IN EACH DIRECTION. PROVIDE ADDITIONAL JOINTS WITH A MAXIMUM SPACING NOT TO EXCEED 36 TIMES THE SLAB THICKNESS. ARRANGE JOINTS SUCH THAT PANEL LENGTH TO WIDTH RATIOS DOES NOT EXCEED 1.5. PROVIDE 3/4" DIAMETER X 1'(4" SMOOTH DOWELS AT 12 INCHES ON CENTER AT SLAB ON GRADE CONSTRUCTION JOINTS. 13. WHERE THE SLAB IS TO RECEIVE SENSITIVE ARCHITECTURAL FLOOR FINISHES, SUCH AS CERAMIC TILE, ALL JOINTS IN THE SLAB CONSTRUCTION SHALL BE PLACED TO ALIGN WITH JOINTS IN THE FINISHED MATERIAL. D. CONCRETE 1. CONCRETE SHALL HAVE NATURAL SAND FINE AGGREGATE AND NORMAL WEIGHT COARSE AGGREGATES CONFORMING TO ASTM C33, TYPE I PORTLAND CEMENT CONFORMING TO ASTM C150, AND SHALL HAVE A COMPRESSIVE STRENGTH (FC') OF 3000 PSI AT 28 DAYS, EXCEPT SLAB ON GRADE TO BE 3,500 PSI. ALL CONCRETE EXPOSED TO WEATHER SHALL BE AIR ENTRAINED 6%±1.5%. ALL STRUCTURAL CONCRETE HAS BEEN DESIGNED BY THE ULTIMATE STRENGTH METHOD AND IN ACCORDANCE WITH THE PROVISIONS OF ACI 318. 2. GROUND GRANULATED BLAST(FURNACE SLAG MAY BE USED AS A POZZOLAN TO REPLACE A PROTION OF THE PORTLAND CEMENT IN A CONCRETE MIX, SUBJECT TO THE APPROVAL OF THE STRUCTURAL ENGINEER. GROUND GRANULATED BLAST(FURNACE SLAG WHEN USED, SHALL CONFORM TO ASTM C989. CONCRETE MIXES USING GROUND GRANULATED BLAST(FURNACE SLAG SHALL BE PROPORTIONED TO ACCOUNT FOR THE PROPERTIES OF THE SPECIFIC GROUND GRANULATED BLAST(FURNACE SLAG USED. THE RATIO OF THE AMOUNT OF THE GROUND GRANULATED BLAST(FURNACE SLAG TO THE TOTAL AMOUNT OF GROUND GRANULATED BLAST(FURNACE SLAB AND CEMENT IN THE MIX SHALL NOT EXCEED 40 PERCENT. 3. GROUT FOR BASE PLATES SHOULD BE NON(SHRINKABLE, NON(METALLIC CONFORMING TO ASTM C827 AND SHALL HAVE A SPECIFIED COMPRESSIVE STRENGTH AT 28 DAYS OF 5,000 PSI. PRE(GROUTING OF BASE PLATES WILL NOT BE PERMITTED. 4. ALL CONCRETE WORK AND SHALL COMPLY WITH THE REQUIREMENTS OF THE ACI BUILDING CODE (ACI 318), AND THE SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301). 5. DETAILING OF CONCRETE REINFORCEMENT BARS AND ACCESSORIES SHALL CONFORM TO THE RECOMMENDATIONS OF ACI 315 "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT" AND ACI SP(66 "DETAILING MANUAL". PLACING OF REINFORCING BARS SHALL CONFORM TO THE RECOMMENDATIONS OF ACI 315R "MANUAL OF ENGINEERING AND PLACING DRAWINGS FOR REINFORCED CONCRETE STRUCTURES" AND CRSI "MANUAL OF STANDARD PRACTICE". 6. MIXING, TRANSPORTING, AND PLACING OF CONCRETE SHALL CONFORM TO ACI 301. 7. MINIMUM CONCRETE COVER PROTECTION FOR REINFORCEMENT BARS SHALL BE AS FOLLOWS: (SEE ACI 318 SECTION 7.7 FOR CONDITIONS NOT NOTED) FOOTINGS 2222222222222222222 .3 INCHES SLABS ON GRADE 2222222222....2.2 INCHES (TOP) WALLS BELOW GRADE (BACKFILLED SIDE) 2.....2.2 INCHES WALLS BELOW GRADE (NO BACKFILL) 2..........2 ...3/4 INCHES 8. PROVIDE STANDARD BAR CHAIRS AND SPACERS AS REQUIRED TO MAINTAIN CONCRETE PROTECTION SPECIFIED. 9. CONCRETE REINFORCEMENT BARS SHALL CONFORM TO ASTM A615, GRADE 60. REINFORCEMENT BARS SHALL NOT BE TACK WELDED, WELDED, HEATED OR CUT UNLESS INDICATED ON THE CONTRACT DOCUMENTS OR REVIEWED BY THE STRUCTURAL ENGINEER. 10. WELDED WIRE FABRIC SHALL CONFORM TO ATSM A185. FABRIC SHALL BE SUPPLIED IN FLAT SHEETS. FABRIC SHALL BE LAPPED A MINIMUM OF 6 INCHES. 11. WELDING OF REINFORCEMENT BARS, WHEN ACCEPTED BY THE STRUCTURAL ENGINEER, SHALL CONFORM TO THE AMERICAN WELDING SOCIETY STANDARD D1.4. ELECTRODES FOR SHOP AND FIELD WELDING OF REINFORCEMENT BARS SHALL CONFORM TO ASTM A233, CLASS E90XX. 12. REINFORCEMENT DESIGNATED AS "CONTINUOUS" SHALL LAP 48 BAR DIAMETERS AT SPLICES UNLESS NOTED OTHERWISE. REINFORCEMENT BAR SPLICES IN GRADE BEAMS SHALL BE LOCATED AT THE CENTERLINE OF SUPPORTS FOR BOTTOM BARS AND AT MIDSPAN FOR TOP BARS. PROVIDE STANDARD ACI HOOKS FOR TOP AND BOTTOM BARS AT DISCONTINUOUS ENDS OF ALL GRADE BEAMS. 13. HORIZONTAL FOOTING AND HORIZONTAL WALL REINFORCEMENT SHALL BE CONTINUOUS AND SHALL HAVE 90(DEGREE BENDS AND EXTENSIONS, OR CORNER BARS OF EQUIVALENT SIZE LAPPED 36 BAR DIAMETERS, AT CORNERS AND INTERSECTIONS. 14. HORIZONTAL JOINTS WILL NOT BE PERMITTED IN CONCRETE CONSTRUCTION EXCEPT AS SHOWN ON THE CONTRACT DOCUMENTS. VERTICAL JOINTS SHALL OCCUR AT CENTER OF SPANS AT LOCATIONS REVIEWED BY THE STRUCTURAL ENGINEER. 15. CONSTRUCTION JOINTS BETWEEN PIERS AND PIER CAPS, FOOTINGS AND WALLS OR COLUMNS, OR WALLS, COLUMNS, BEAMS AND THE FLOOR SYSTEM THEY SUPPORT SHALL BE PREPARED BY ROUGHENING THE CONTACT SURFACE TO A FULL AMPLITUDE OF APPROXIMATELY 1/4 INCH LEAVING THE CONTACT SURFACE CLEAN AND FREE OF LAITANCE. 16. CONCRETE STRENGTH, PROPORTIONS AND TESTING SHALL MEET THE FOLLOWING REQUIREMENTS: a. CONCRETE STRENGTH SHALL NOT BE LESS THAN STRENGTHS LISTED ABOVE AT 28 DAYS. b. THE MIX DESIGN SHALL BE PREPARED BY AN INDEPENDENT TESTING LABORATORY APPROVED BY THE OWNER USING MATERIALS TO BE USED ON THE JOB. THE LABORATORY MIX DESIGN SHALL EXCEED THE DESIRED JOB STRENGTH OF CONCRETE BY 1,200 PSI. FOUR COPIES OF MIX DESIGN SHALL BE SUBMITTED TO THE OWNER BEFORE CONCRETE WORK HAS BEGUN. C. SLUMP SHALL NOT EXCEED 4 INCHES. D. ALL COSTS OF CONCRETE TESTING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. TESTING OF CONCRETE SHALL BE ACCOMPLISHED BY TAKING FOUR STANDARD TEST CYLINDERS OF THE CONCRETE FOR EACH DAY CONCRETE IS POURED. ONE SET OF TEST CYLINDERS MAY REPRESENT NO MORE THAN 55 CUBIC YARDS OF CONCRETE NOR ONE DAY'S POUR. CYLINDERS SHALL BE BROKEN TWO AT 7 DAYS AND TWO AT 28 DAYS IN ACCORDANCE WITH ASTM SPECIFICATIONS. FOR ALL CONCRETE, SLUMP CONE TEST SHALL BE RUN AT THE JOB SITE ON EACH TRUCK DELIVERY. CONCRETE USED FOR SLUMP CONE TEST SHALL NOT BE TAKEN FROM FIRST OR LAST 15% OF EACH LOAD. ALL TEST CYLINDERS AND SLUMP CONE TESTS SHALL BE PERFORMED BY A QUALIFIED TECHNICIAN FROM AN APPROVED TESTING FIRM IF DIFFERENT FROM GEOTECHNICAL ENGINEERS USED TO MONITOR SITE GRADING. 31. THE FOLLOWING ENVIRONMENTAL REQUIREMENTS SHALL BE MET AND MAINTAINED: A. PROVIDE COLD WEATHER AND/OR HOT WEATHER PROTECTION AS RECOMMENDED IN ACI 306 AND ACI 305. B. UNLESS ADEQUATE PROTECTION IS PROVIDED, CONCRETE SHALL NOT BE PLACED DURING RAIN, SLEET OR SNOW. PROTECT CONCRETE FROM RAIN WATER, MAINTAIN CONCRETE WATER RATIO AND PROTECT CONCRETE SURFACE. C. ALL CONCRETE SHALL BE ADEQUATELY PROTECTED AFTER POURING TO PREVENT DAMAGE FROM FREEZING, BY THE USE OF SUITABLE COVERS AND ADEQUATE HEATING EQUIPMENT. FROZEN AND DAMAGED CONCRETE MUST BE REMOVED AND REPLACED AT THE CONTRACTOR'S EXPENSE. DO NOT PLACE CONCRETE ON FROZEN EARTH. D. ADMIXTURES TO RETARD OR ACCELERATE SETTING, REDUCE WATER RATIO OR PREVENT FREEZING SHALL NOT BE USED WITHOUT PRIOR APPROVAL FROM TENANT. NO ADMIXTURES CONTAINING CALCIUM CHLORIDE MAY BE USED. E. DO NOT PLACE CONCRETE WHEN TEMPERATURE IS 40 DEGREES F. AND FALLING OR WHEN FREEZING WEATHER IS PREDICTED WITHIN 24 HOURS. "RECOMMENDED PRACTICE FOR WINTER CONCRETING", ACI 604, MAY BE FOLLOWED FOR PLACING CONCRETE IN COLD WEATHER. F. NO CALCIUM CHLORIDE OR OTHER ACCELERATORS OR ANTI(FREEZES SHALL BE USED. E. ROOF DECK 1. ROOF DECK SHALL BE RIGID INSULATION BOARD ON PAINTED TYPE B ROOF DECK. TYPE B DECK SHALL BE 22 GAGE COLD FORMED STEEL CONFORMING TO ASTM A653 SQ GRADE 33. METAL DECK SHALL BE 1(1/2 INCHES DEEP WITH A MINIMUM SECTION MODULUS (SP) OF 0.186 INCHES CUBED PER FOOT OF WIDTH. 2. PROPERTIES AND ALLOWABLE STRESSES OF STEEL ROOF DECKS SHALL BE BASED ON THE AISI "SPECIFICATION FOR THE DESIGN OF COLD(FORMED STEEL STRUCTURAL MEMBERS". 3. PLUG WELD DECK TO SUPPORTING STEEL AND ADJOINING DECK SHEETS IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE AMERICAN WELDING SOCIETY STANDARD D1.3. 30 INCH WIDE DECK SHEETS SHALL BE WELDED AT END LAPS AND END SUPPORTS USING A 12(6(12 PATTERN (A WELD AT EACH SIDE LAP AND AT THE THIRD AND FOURTH FLUTES), AND WELDED AT INTERMEDIATE SUPPORTS USING A 12(18 STAGGERED PATTERN (A WELD AT EACH SIDE LAP AND AT THIRD OR FOURTH FLUTES). 36 INCH WIDE DECK SHEETS SHALL BE WELDED AT END LAPS, END SUPPORTS AND INTERMEDIATE SUPPORTS USING 4 WELDS PER SHEET (A WELD AT EACH SIDE LAP AND AT EVERY OTHER FLUTE). DECK SHEETS SHALL BE WELDED AT EACH VALLEY AND 12 INCHES O.C. ALONG SIDE LAPS TO ALL SUPPORTS WITHIN 6 FEET FROM THE INSIDE FACE OF THE PERIMETER WALL. SIDE LAPS BEYOND 6 FEET FROM THE INSIDE FACE OF THE PERIMETER WALL SHALL BE FASTENED TOGETHER WITH ATTACHMENTS AT MIDSPAN BETWEEN JOISTS. PROVIDE ADDITIONAL DECK WELDS AS SHOWN ON THE DRAWINGS. 4. USE WELDING WASHERS ON ALL CONNECTIONS OF STEEL DECK WITH METAL THICKNESS LESS THAN 22 GA. TO STRUCTURAL STEEL SUPPORTS CONCRETE. F. STRUCTURAL STEEL 1. ALL STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH THE LATEST AISC CODE. ALL WIDE FLANGE SHAPES SHALL BE ASTM A992/A572 GRADE 50. ALL OTHER STRUCTURAL STEEL SHALL BE ASTM A36 UNO. A. ALL STEEL RECTANGULAR/SQUARE HOLLOW STRUCTURAL SECTIONS SHALL BE ASTM A500 GRADE B, FY=46 KSI. B. ALL STEEL PIPE SECTIONS SHALL BE ASTM A501 OR ASTM A53, TYPE E OR S GRADE B. C. ALL STEEL SHALL HAVE A SHOP COAT OF RUST INHIBITIVE PAINT. D. ALL STEEL SHALL BE THOROUGHLY CLEANED IN ACCORDANCE WITH SSPC( SP3 PRIOR TO PAINTING. 2. ANCHOR BOLTS SHALL CONFORM TO ASTM F1554, GRADE 36, UNLESS NOTED OTHERWISE. 3. CONNECTION BOLTS FOR STRUCTURAL STEEL MEMBERS SHALL BE HIGH STRENGTH BOLTS WHICH MEET OR EXCEED THE REQUIREMENTS OF ASTM A325, TYPE N, X, OR F. BOLTS SHALL BE DESIGNED AS BEARING TYPE BOLTS, EXCEPT AS NOTED. BOLTS SHALL BE INSTALLED IN ACCORDANCE WITH THE "SNUG TIGHT" CONDITION AS OUTLINED IN THE "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS". BOLTS SHALL HAVE A HARDENED WASHER PLACED UNDER THE ELEMENT TO BE TIGHTENED. BOLTS IN BRACING CONNECTIONS, MOMENT CONNECTIONS OR OTHER CONNECTIONS NOTED ON THE DRAWINGS SHALL BE CONSIDERED TO BE "SLIP CRITICAL" BOLTS, AND SHALL BE DESIGNED AS FRICTION TYPE BOLTS. FRICTION TYPE CONNECTIONS SHALL BE TIGHTENED BY THE USE OF THE TURN(OF(THE(NUT METHOD OR THE USE OF LOAD INDICATING TYPE BOLTS, INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 4. STRUCTURAL STEEL DETAILING, FABRICATION AND ERECTION SHALL CONFORM TO THE AISC "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" AND THE AISC "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES". 5. TYPICAL CONNECTION DETAILS ARE INDICATED ON THE DRAWINGS. THE FABRICATOR SHALL PREPARE THE SHOP DRAWINGS FOR THE PROJECT BASED ON THIS CONNECTION DESIGN INFORMATION. IF ALTERNATE CONNECTION DESIGNS ARE USED, THE FABRICATOR SHALL HAVE A REGISTERED PROFESSIONAL ENGINEER PREPARE THE CONNECTION DESIGNS. SUCH DESIGNS SHALL BE SUBMITTED WITH THE SHOP DRAWINGS AND SHALL BEAR THE SEAL OF THIS RESPONSIBLE PROFESSIONAL ENGINEER. THE FABRICATOR IS RESPONSIBLE FOR THE SELECTION, DESIGN AND DETAILING OF ALL CONNECTIONS NOT FULLY DETAILED ON THE CONTRACT DRAWINGS. CONNECTIONS SHALL BE DESIGNED AND DETAILED IN ACCORDANCE WITH THE AISC "MANUAL OF STEEL CONSTRUCTION ", LATEST EDITION. TABLE II AND TABLE III OF PART 4 SHOULD BE USED. THE END REACTION OF THE CONNECTED BEAM SHALL BE DETERMINED FROM PART 2 "ALLOWABLE LOADS ON BEAMS" FOR THE MEMBER SIZE AND SPAN INDICATED, UNLESS A DESIGN REACTION IS INDICATED ON THE PLANS. IN NO CASE SHALL THE END REACTION BE TAKEN AS LESS THAN 12.0 KIPS. 6. STEEL FABRICATOR IS SOLELY RESPONSIBLE FOR SURVEYING AND VERIFICATION OF EXISTING CONDITIONS INCLUDING BUT NOT LIMITED TO THE LOCATION, ELEVATION, AND DIMENSIONS OF EXISTING WALLS AND FRAMING. 7. PRIOR TO DETAILING CONNECTIONS FOR STRUCTURAL STEEL, THE STEEL FABRICATOR SHALL SUBMIT FOR APPROVAL REPRESENTATIVE DETAILS AND CALCULATIONS FOR EACH TYPE OF STRUCTURAL STEEL CONNECTION TO BE UTILIZED. AFTER APPROVAL, THE CONNECTIONS MAY BE INCORPORATED INTO THE SHOP DRAWINGS, ALONG WITH A TABLE OF DESIGN CAPACITIES FOR THE RANGE OF CONNECTIONS TO BE USED. 8. WELDING SHALL CONFORM TO THE AMERICAN WELDING SOCIETY STANDARD D1.1. ELECTRODES FOR SHOP AND FIELD WELDS SHALL CONFORM TO AWS A5.1 OR AWS A5.5, CLASS E70XX, LOW HYDROGEN. 9. ALL SHOP AND FIELD WELDING SHALL BE PERFORMED BY WELDERS CERTIFIED, AS DESCRIBED IN "AMERICAN WELDING SOCIETY'S STANDARD QUALIFICATION PROCEDURE", AWS D1.1, TO PERFORM THE TYPE OF WORK REQUIRED. 10. SPLICING OF STRUCTURAL STEEL MEMBERS WHERE NOT DETAILED ON THE CONTRACT DOCUMENTS IS PROHIBITED WITHOUT THE PRIOR APPROVAL OF THE STRUCTURAL ENGINEER AS TO LOCATION, TYPE OF SPLICE AND CONNECTION TO BE MADE. 11. THE CONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER OF ANY MISFABRICATED STRUCTURAL STEEL PRIOR TO ERECTION OF SAME. 12. PENETRATIONS SHALL NOT BE CUT IN STRUCTURAL STEEL MEMBERS UNLESS SO INDICATED IN THE DRAWINGS OR AS REVIEWED BY THE ENGINEER. 13. HEADED CONCRETE ANCHORS SHALL BE NELSON OR KSM HEADED CONCRETE ANCHORS (OR ACCEPTABLE EQUAL), AND SHALL CONFORM TO ASTM A108, GRADES C(1010 THROUGH C(1020. ANCHORS SHALL BE AUTOMATICALLY END WELDED WITH SUITABLE STUD WELDING EQUIPMENT IN THE SHOP OR IN THE FIELD. WELDING SHALL BE IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE NELSON STUD WELDING COMPANY OR THE KSM WELDING SYSTEMS COMPANY. 14. STEEL MEMBERS, FABRICATIONS AND ASSEMBLIES INDICATED ON THE DRAWINGS TO BE GALVANIZED SHALL BE GALVANIZED AFTER FABRICATION BY HOT DIP PROCESS IN ACCORDANCE WITH ASTM A123. WEIGHT OF ZINC COATING TO CONFORM TO THE REQUIREMENTS SPECIFIED UNDER "WEIGHT OF COATING" IN ASTM A123 OR ASTM A386, AS APPLICABLE. 15. ALL LINTELS AND SHELF ANGLES SHALL BE HOT DIP GALVANIZED 16. ANY POINTS OF WELDING SHALL BE TOUCHED UP IN THE FIELD WITH A ZINC(RICH PAINT BY THE STEEL ERECTOR. G. JOISTS 1. OPEN WEB STEEL JOISTS AND BRIDGING FOR JOISTS SHALL CONFORM TO THE STEEL JOIST INSTITUTE "STANDARD SPECIFICATIONS FOR OPEN WEB STEEL JOISTS". ERECTION LAYOUT, CALCULATIONS, DETAILS, AND ANY OTHER INFORMATION DEEMED NECESSARY BY THE ENGINEER SHALL BE SUBMITTED FOR REVIEW PRIOR TO FABRICATION. TOP CHORDS SHALL BE ANGLES OR TEES. JOISTS SHALL BE WELDED TO SUPPORTING STEEL MEMBERS. WHERE COLUMNS ARE NOT FRAMED IN AT LEAST TWO DIRECTIONS WITH STEEL BEAMS OR JOIST GIRDERS, THE JOIST AT THE COLUMN LINE SHALL BE BOLTED TO SUPPORTING MEMBERS DURING ERECTION. BRIDGING SHALL BE CONTINUOUS THROUGH OPEN WEB STEEL JOISTS AND BE ANCHORED TO SPANDREL MEMBERS. PROVIDE DIAGONAL BRIDGING WITH BOLTED CONNECTIONS AT CHORDS AND INTERSECTIONS WHERE REQUIRED BY SJI. CAMBER ALL JOISTS THE AMOUNT RECOMMENDED BY THE SJI. OPEN WEB STEEL JOISTS MARKED "SPECIAL" OR "SP" SHALL BE DESIGNED BY THE JOIST MANUFACTURER TO SUPPORT THE DEAD AND LIVE UNIFORM AND CONCENTRATED LOADS AND/OR NET UPLIFT LOADS NOTED IN THE DRAWINGS. 2. DESIGN ALL JOISTS FOR NET UPLIFT OF 10 PSF, UNLESS NOTED OTHERWISE ON THE PLANS. 3. ALL JOISTS SHALL HAVE A SHOP COAT OF RUST INHIBITIVE NON(BITUMINOUS PAINT. 4. STEEL JOISTS SHALL BE DESIGNED, FABRICATED AND ERECTED TO THE REQUIREMENTS OF THE SPECIFICATIONS OF THE STEEL JOIST INSTITUTE FOR SERIES K JOISTS MANUFACTURER SHALL BE A MEMBER OF THE STEEL JOIST INSTITUTE. ALL BRIDGING SHALL BE IN ACCORDANCE WITH SJI STANDARDS UNLESS NOTED OTHERWISE IN THE DRAWINGS. H. MASONRY 1. MASONRY UNITS SHALL BE TYPE: A. ASTM C90 SOLID OR ASTM C90 HOLLOW GROUTED SOLID BELOW GRADE. B. ASTM C90 HOLLOW ABOVE GRADE C. WITH MINIMUM COMPRESSIVE STRENGTH OF 1900 PSI D. ALL CMU SHALL BE LAID IN A FULL BED OF MORTAR. 2. FOLLOWING ARE THE BLOCK STRENGTHS REQUIRED: A. ASTM C90 SOLID 1900 PSI ON GROSS AREA OF INDIVIDUAL UNITS. B. ASTM C90 HOLLOW 1900 PSI ON NET AREA OF INDIVIDUAL UNITS. 3. ALL MORTAR SHALL BE ASTM C270 TYPE S. 4. GROUT SHALL BE A HIGH SLUMP MIX A. IN ACCORDANCE WITH ASTM SPECIFICATION C476 B. HAVING A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI. C. FROM FIELD OBTAINED TEST CYLINDERS. 5. LAID UP MASONRY DESIGN F'M IS 1350 PSI FOR STANDARD CONCRETE MASONRY. 6. ALL CONCRETE MASONRY SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES ACI 530/ASCE 5/TMS 402" AND "SPECIFICATIONS FOR MASONRY STRUCTURES ACI 530.1/ASCE 6/TMS 602. A. AND INSPECTED BY A QUALIFIED ENGINEER. 7. ALL BRICK MASONRY UNITS SHALL BE GRADE SW IN ACCORDANCE WITH ASTM C216 WITH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AND BONDED TOGETHER WITH TYPE S MORTAR. 8. PROVIDE HOT(DIPPED GALVANIZED TRUSS TYPE HORIZONTAL JOINT REINFORCEMENT, MIN. 9 GA, AT 16" ON CENTER VERTICAL IN ALL MASONRY WALLS. SPACE HORIZONTAL JOINT REINFORCEMENT AT 8 INCHES ON CENTER IN ALL PARAPETS. USE SHOP FABRICATED SPECIAL PIECES AT ALL CORNERS AND TEES. 9. PROVIDE 1(#5 VERTICAL AT EACH END, CORNER AND INTERSECTION OF ALL WALLS. 10. PROVIDE MASONRY ACCESSORIES TO SECURE VERTICAL REINFORCEMENT IN PLACE AND CORRECTLY POSITIONED. VERTICAL REINFORCEMENT IS TO BE CENTERED IN THE MASONRY CELLS UNLESS INDICATED OTHERWISE. 11. CELLS TO BE GROUTED SHALL BE CLEAN AND FREE OF EXCESS MORTAR AND FOREIGN MATERIALS. 12. LINTELS SHALL BEAR ON MASONRY WALLS A MINIMUM OF 8" AT EACH END. FOR CMU WALLS, PROVIDE TWO GROUTED CORES EACH SIDE OF OPENING FULL HEIGHT OF WALL AND REINFORCE EACH OF THE TWO GROUTED CORES WITH 1(#5 VERTICAL EXTENDING FROM THE FOUNDATION TO THE POINT OF LATERAL SUPPORT FOR THE WALL ABOVE THE LINTEL LOCATION. UNLESS NOTED OTHERWISE, THE FOLLOWING LINTELS MAY BE USED WHEN THE HEAD OF THE MASONRY OPENING IS BELOW FLOOR OR ROOF BEARING ELEMENTS BY A MINIMUM DISTANCE OF 75% OF THE LINTEL SPAN: Galvanized Steel CMU Lintel Precast Concrete Lintel Span Angle Lintel per per 4" CMU wythe per 4" CMU Wythe 4" Masonry wythe (fm'= 1500 psi) (fc'= 3000 psi) 0 ( 4'(0" L3(1/2 x 3(1/2 x 1/4 8" Deep w/ (1) 1#4 8" Deep w/ (1) #4 Bottom Top & Bottom 4'(1" ( 6'(0" L5 x 3(1/2 x 5/16 8" Deep w/ (1) #5 8" Deep w/ (1) #4 Bottom Top & Bottom 6'(1" ( 8'(0" L5 x 3(1/2 x 3/8 16" Deep w/ (1) #4 8" Deep w/ (1) #4 Bottom Top & Bottom 8'(1" ( 12'(0" L6 x 3(1/2 x 1/2 16" Deep w/ (1) #5 8" Deep w/ (1) #5 Bottom Top & Bottom 13. TEMPORARY SHORING OF LINTELS MUST BE PROVIDED UNTIL MASONRY HAS CURED. CONTROL JOINTS IN MASONRY SHALL NOT BE LOCATED WITHIN A DISTANCE EQUAL TO 50% OF THE LINTEL SPAN ADJACENT TO EACH SIDE OF THE OPENING. 14. HORIZONTAL JOINT REINFORCEMENT SHALL BE USED IN THE MASONRY CONSTRUCTION. SUCH JOINT REINFORCEMENT SHALL BE PLACED AT 8 INCHES ON CENTER VERTICALLY IN WALLS BELOW GRADE AND AT 16 INCHES ON CENTER VERTICALLY IN WALLS THAT ARE ABOVE GRADE. HORIZONTAL JOINT REINFORCEMENT SHALL BE FABRICATED FROM GALVANIZED COLD(DRAWN STEEL WIRE CONFORMING TO ASTM A82. REINFORCEMENT SHALL CONSIST OF TWO OR MORE SMOOTH OR DEFORMED LONGITUDINAL WIRES NO. 9 GAGE OR LARGER, WELD CONNECTED WITH NO. 12 GAGE OR LARGER CROSS WIRES. GALVANIZE COATING SHALL CONFORM TO ASTM A116 AND SHALL BE APPLIED AT A WEIGHT OF NOT LESS THAN 1.5 OUNCES PER SQUARE FOOT OF UNCOATED WIRE SURFACE. THE OUT(TO(OUT SPACING OF THE LONGITUDINAL WIRES SHOULD BE 1(5/8 INCHES LESS THAN THE WIDTH OF THE MASONRY UNITS. THE DISTANCE BETWEEN THE WELDED CONTACTS OF THE CROSS WIRES WITH EACH LONGITUDINAL WIRE SHOULD NOT EXCEED 6 INCHES AND 16 INCHES FOR SMOOTH AND DEFORMED LONGITUDINAL WIRES RESPECTIVELY. 15. CONTROL JOINTS SHALL BE PLACED IN THE MASONRY CONSTRUCTION SUCH THAT THE PANEL LENGTH TO HEIGHT RATIO OF THE WALL DOES NOT EXCEED 2.5, AND THAT THE MAXIMUM PANEL LENGTH OF WALL DOES NOT EXCEED 25 FEET. ADDITIONAL JOINTS SHALL BE PLACE WHERE ABRUPT CHANGES IN WALL SECTIONS OCCUR. 16. MASONRY CONSTRUCTION SHALL BE INSPECTED DURING THE VARIOUS WORK STAGES BY A QUALIFIED INSPECTOR. INSPECTION SHALL INCLUDE CHECKING FOR COMPLIANCE WITH PROJECT DRAWINGS AND SPECIFICATIONS, INCLUDING RECORDING OF THE FOLLOWING: I. QUALITY AND TESTING OF MASONRY UNITS AND MATERIALS FOR MORTAR, GROUT, AND MAKING OF PRISMS WHEN REQUIRED. II. PROPORTIONING, MIXING, AND CONSISTENCY OF MORTAR AND GROUT. III. LAYING, MORTARING, AND GROUTING OF MASONRY UNITS AND ELEMENTS. IV. CONDITION, GRADE, SIZE, SPACING AND PLACEMENT OF REINFORCEMENT. V. SIGNIFICANT OR UNUSUAL CONSTRUCTION LOADS ON MASONRY STRUCTURAL ELEMENTS. VI. WHEN AMBIENT TEMPERATURE FALLS BELOW 40 DEGREES F OR RISES ABOVE 100 DEGREES F, A COMPLETE RECORD OF WEATHER CONDITIONS AND OF PRECONDITIONING AND PROTECTION GIVEN TO MASONRY MATERIALS, AND PROTECTION AND CURING OF COMPLETED WORK, SHALL BE MAINTAINED. VII. GENERAL PROGRESS OF WORK. 17. FOR MASONRY WALLS OVER EIGHT FEET IN HEIGHT, PROVIDE CONSTRUCTION BRACING SHOP DRAWINGS AND CALCULATIONS SIGNED AND SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE JURISDICTION OF CONSTRUCTION. I. DEMOLITION ALL WORK SHALL BE IN GENERAL COMPLIANCE WITH THE APLICABLE CODE. FURNISH ALL LABOR AND MATERIALS NECESSARY TO PERFORM THE DEMOLITION WORK IN A COMPLETED MANNER SUCH THAT NEW WORK CAN BE INSTALLED WITH MINIMUM PREPARATION CONTRACTOR SHALL INCLUDE IN THE SCOPE OF WORK ALL ASPECTS OF REQUIRED DEMOLITION, SHORING OF EXISTING STRUCTURE, STAGING THE REPAIR TASKS AND SCHEDULING THE WORK IN A MANNER APPROVED BY THE BUILDING MANAGEMENT, CLEAN UP AFTER PORTIONS OF WORK ARE PERFROMED AND CLEAN UP AFTER THE ENTIRE REPAIR IS COMPLETED. THE CONTRACTOR SHALL TAKE PRECAUTIONS TO PREVENT DAMAGE OF THE EXISTING STRUCTURE. IN THE EVENT OF DAMAGE, CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AND CONTACT THE STRUCTURAL ENGINEER FOR ASSESSMENT OF THE DAMAGE. SCHEDULE ALL WORK IN A CAREFUL MANNER WITH ALL NECESSARY CONSIDERATION FOR FACILITY OPERATIONS, AND FACILITY PERSONNEL. ANY DAMAGE TO PERSON OR PROPERTY AS A RESULT OF DEMOLITION AND RELATED WORK SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. ERECT BARRIER FENCES, GUARD RAILS, WARNING DEVICES AND SHORING TO PROTECT PERSONNEL WORKING IN THE AREA. SUBMIT PROCEDURES AND SCHEDULE PROPOSED FOR THE ACCOMPLISHMENT OF THE DEMOLITION WORK TO THE OWNER FOR APPROVAL. INCLUDE SAFE CONDUCT OF THE WORK, DISPOSITION OF MATERIALS, PROTECTION OF REMAINING PROPERTY AND COORDINATION WITH OTHER WORK. THE CONTRACTOR SHALL TAKE MEASURES TO COORDINATE THE CONSTRUCTION SUCH THAT INTERFERENCE OF EXISTING REINFORCING STEEL WITH PLACEMENT OF NEW ANCHORS (DOWELS, EXPANSION BOLTS, ADHESIVE ANCHORS) DOES NOT OCCUR. IF EXISTING REINFORCING STEEL IS ENCOUNTERED DURING DRILLING, ADJUST THE ANCHOR LOCATION IF POSSIBLE AND NOTIFY THE ENGINEER. ABANDONED HOLES SHALL BE FILLED WITH GROUT. ANCHORS SHALL BE SET WITHIN 3 INCHES OF THEIR SPECIFIED LOCATION, BUT AT LEAST 1 INCH FROM ANY ABANDONED HOLE. CARE SHALL BE TAKEN NOT TO BREAK OR DAMAGE REINFORCING STEEL DURING DRILLING, UNLESS OTHERWISE DIRECTED BY THE ENGINEER. Drawn: Checked: Scale: Construction Documents for: 1902 campus commons drive suite 101 reston, virginia 20191 Tel: 703.476.3900 Fax: 703.264.0733 www.archinc.com Issued All reproduction + intellectual property rights reserved by Architecture Incorporated © 2016 RENOVATION AND ADDITION AS NOTED 3930 Pender Drive, Suite175 Fairfax, VA 22030 (703) 890(5000 email: [email protected] Project No 16745.00 801 N. MAIN STREET, BRIDGEWATER, VA 22181 T:\2016 Drawings\Design Projects ( SK & DW\16745.00 John Wayland ES\16745_John Wayland ES Structural Model (Revit 16).rvt 1/31/2017 9:15:54 AM S0.1 STRUCTURAL NOTES Project: 16745.00 Author Checker ROCKINGHAM CO. PUBLIC SCHOOLS JOHN WAYLAND ES BID SET BID SET BID SET 02(01(2017 Revisions
11

S0 · 2017. 2. 7. · aci 315 "details and detailing of concrete reinforcement" and aci sp(66 "detailing manual". placing of reinforcing bars shall conform to the recommendations

Feb 13, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • STRUCTURAL NOTES

    A. BUILDING CODE

    1. THE STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE 2012 VIRGINIA UNIFORM STATEWIDE BUILDING CODE WITH

    LOCAL AMENDMENTS.

    B. GENERAL

    1. FOR LOADING CRITERIA SEE ADJACENT TABLE.

    2. THE STRUCTURE HAS BEEN DESIGNED TO WITHSTAND THE WIND PRESSURES SPECIFIED IN SECTION 1609.0 OF THE

    INTERNATIONAL BUILDING CODE. SEE THE ATTACHED LOAD TABLE.

    3. THE STRUCTURE HAS BEEN DESIGNED TO WITHSTAND THE SNOW LOADS SPECIFIED IN SECTION 1608.0 OF THE

    INTERNATIONAL BUILDING CODE AND SECTION 7 OF ASCE 7. SEE THE ATTACHED DESIGN DATA TABLE ON THIS SHEET.

    4. IN ADDITION TO THE FLAT ROOF SNOW LOAD STATED ABOVE, A SNOW LOAD PROVISION FOR DRIFTING SNOW HAS BEEN

    PROVIDED IN ACCORDANCE WITH THE REQUIREMENTS OF ASCE 7, SECTIONS 7.7 AND 7.8.

    5. THE STRUCTURE HAS BEEN DESIGNED TO WITHSTAND THE SEISMIC FORCES SPECIFIED IN SECTION 1613.0 OF THE

    INTERNATIONAL BUILDING CODE. SEE THE SEISMIC DESIGN LOAD AND DATA TABLE ON THIS SHEET.

    6. METHODS, PROCEDURES, AND SEQUENCES OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE

    CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO MAINTAIN AND INSURE THE INTEGRITY OF THE STRUCTURE AT

    ALL STAGES OF CONSTRUCTION.

    7. CONTRACTOR MUST FABRICATE AND ERECT STEEL IN ACCORDANCE WITH OSHA'S SAFETY REQUIREMENTS, 29 CFR

    PART 1926 SAFETY STANDARDS FOR STEEL ERECTION; FINAL RULE.

    8. STRUCTURAL MEMBERS HAVE BEEN LOCATED AND DESIGNED TO ACCOMMODATE THE MECHANICAL EQUIPMENT AND

    OPENINGS SPECIFIED BY THE MECHANICAL CONSULTANT. ANY SUBSTITUTIONS RESULTING IN REVISIONS TO THE

    STRUCTURE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE STRUCTURAL ENGINEER.

    9. THE GENERAL CONTRACTOR AND SUB(CONTRACTORS SHALL DETERMINE THE SCOPE OF THE STRUCTURAL WORK

    FROM THE CONTRACT DOCUMENTS TAKEN AS A WHOLE. THE STRUCTURAL DRAWINGS SHALL NOT BE CONSIDERED

    SEPARATELY FOR PURPOSES OF BIDDING THE STRUCTURAL WORK. DUE CONSIDERATION SHALL BE GIVEN TO OTHER

    STRUCTURAL WORK OR WORK RELATED TO THE STRUCTURE, INCLUDING NECESSARY COORDINATION DESCRIBED OR

    IMPLIED BY THE ARCHITECTURAL AND MECHANICAL DRAWINGS.

    10. WRITTEN PERMISSION MUST BE OBTAINED FROM BEI STRUCTURAL ENGINEERS, INC., PRIOR TO THE REPRODUCTIVE

    USE OF THE STRUCTURAL CONTRACT DOCUMENTS IN ANY FASHION AS STRUCTURAL SHOP DRAWING DOCUMENTS.

    11. SCALES NOTED ON THE DRAWINGS ARE FOR GENERAL INFORMATION ONLY. NO DIMENSIONAL INFORMATION SHALL BE

    OBTAINED BY DIRECT SCALING OF THE DRAWINGS.

    12. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF ALL RESULTING REVISIONS TO THE STRUCTURAL

    SYSTEM AS A RESULT OF ACCEPTANCE OF CONTRACTOR PROPOSED ALTERNATIVES OR SUBSTITUTIONS.

    13. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR FITTING NEW WORK WITH EXISTING CONSTRUCTION. INFORMATION

    ON EXISTING BUILDINGS SHOWN IN THESE DRAWINGS WAS BASED UPON THE INFORMATION SUPPLIED TO THE STRUCTURAL

    ENGINEER. THIS INFORMATION IS NOT AS(BUILT DATA AND THE ACTUAL AS(BUILT CONSTRUCTION MAY DIFFER FROM THAT

    REPRESENTED IN THE DRAWINGS. CONTRACTOR SHALL VERIFY ALL INFORMATION. VARIATIONS FROM THE DIMENSIONS

    INDICATED ON THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND/OR THE

    STRUCTURAL ENGINEER.

    14. SHORING OF THE EXISTING STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PROVIDE

    TEMPORARY SHORING WHERE MODIFICATIONS/ALTERATIONS TO EXISTING STRUCTURE IS REQUIRED. THE SHORING

    DRAWINGS/CALCULATIONS SHALL BE SIGNED AND STAMPED BY A REGISTERED STRUCTURAL ENGINEER IN THE STATE OF

    JURISDICTION AND SUBMITTED FOR APPROVAL PRIOR TO START OF DEMO WORK.

    15. PRINCIPAL OPENINGS IN THE STRUCTURE ARE INDICATED ON THE CONTRACT DOCUMENTS. REFER TO THE

    ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR SLEEVES, CURBS, INSERTS, ETC. NOT HEREIN

    INDICATED. OPENINGS IN SLABS WITH A MAXIMUM SIDE DIMENSION OR DIAMETER OF 12 INCHES OR LESS SHALL NOT

    REQUIRE ADDITIONAL FRAMING OR REINFORCEMENT, UNLESS NOTED OTHERWISE. THE LOCATION OF SLEEVES OR

    OPENINGS IN STRUCTURAL MEMBERS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW.

    16. ALL NON(PRIMARY STRUCTURAL ELEMENTS SUCH AS STAIRS, RAILINGS, LADDERS, METAL STUDS, STOREFRONTS,

    MULLIONS, ETC. SHALL BE DESIGNED BY A REGISTERED ENGINEER TO MEET THE MINIMUM REQUIREMENTS OF THE LOCAL

    BUILDING CODES. SUBMIT CALCULATIONS AND SHOP DRAWINGS WITH A SIGNED SEAL OF THE RESPONSIBLE REGISTERED

    ENGINEER FOR THE LOCAL JURISDICTION.

    C. FOUNDATION AND SLAB ON GRADE

    1. SOIL BEARING VALUE ASSUMED TO BE 1500 PSF FOR FOOTINGS FOUNDED ON UNDISTURBED NATURAL SOIL OR

    CONTROLLED STRUCTURAL FILL IN ACCORDANCE WITH SUBSURFACE INVESTIGATION AND GEOTECHNICAL ENGINEERING

    REPORT . SOIL BEARING CAPACITY SHALL BE FIELD VERIFIED BY A SOILS ENGINEER REGISTERED IN THE STATE OF

    JURISDICTION.

    2. BOTTOMS OF ALL FOOTINGS SHALL EXTEND A MINIMUM OF ONE FOOT INTO UNDISTURBED SOIL OR CONTROLLED

    COMPACTED FILL AND WHERE SUBJECT TO FROST ACTION, AT LEAST TWO FEET SIX INCHES BELOW FINISHED GRADE.

    ELEVATIONS SHOWN ARE TO TOPS OF FOOTINGS, AND ARE FOR ESTIMATING PURPOSES ONLY. FOOTING ELEVATIONS SHALL

    BE ADJUSTED AS REQUIRED TO SUIT FIELD CONDITIONS. BORING LOGS ARE ON FILE AT THE ARCHITECT'S OFFICE FOR

    REVIEW BY THE CONTRACTOR. ALL FOUNDATION WORK TO BE DONE IN STRICT ACCORDANCE WITH THE GEOTECHNICAL

    REPORT AND BE INSPECTED AND APPROVED BY A SOILS ENGINEER PRIOR TO POURING CONCRETE. ALL CONTROLLED

    COMPACTED FILL SHALL BE PLACED UNDER THE SUPERVISION OF A SOILS ENGINEER.

    3. THE FOUNDATION FOR THE STRUCTURE HAS BEEN DESIGNED FOR THE FOLLOWING LATERAL EARTH PRESSURES:

    CANTILEVER RETAINING WALLS 65 PCF

    4. EXCAVATIONS FOR SPREAD FOOTINGS, COMBINED FOOTINGS, CONTINUOUS FOOTINGS AND/OR MAT FOUNDATIONS

    SHALL BE CLEANED AND HAND TAMPED TO A UNIFORM SURFACE. FOOTING EXCAVATIONS SHALL HAVE THE SIDES AND

    BOTTOMS TEMPORARILY LINED WITH 6 MIL VISQUEEN IF PLACEMENT OF CONCRETE DOES NOT OCCUR WITHIN 24 HOURS OF

    THE EXCAVATION OF THE FOOTING.

    5. FOUNDATION CONDITIONS NOTED DURING CONSTRUCTION, WHICH DIFFER FROM THOSE DESCRIBED IN THE

    GEOTECHNICAL REPORT SHALL BE REPORTED TO THE ARCHITECT, STRUCTURAL ENGINEER AND GEOTECHNICAL ENGINEER

    BEFORE FURTHER CONSTRUCTION IS ATTEMPTED.

    6. REINFORCEMENT PLACEMENT SEQUENCE FOR FOOTINGS IS NOTED ONLY FOR MAJOR REINFORCEMENT BAR LAYERS.

    IN SPREAD FOOTINGS AND MATS THE CONTRACTOR SHALL SEQUENCE ALL OTHER BAR PLACEMENTS AS REQUIRED TO

    CONFORM TO THE CONTRACT DOCUMENTS.

    7. WALLS RETAINING BACKFILL HAVE BEEN DESIGNED FOR IN SERVICE LOADS ONLY. THE CONTRACTOR SHALL PROVIDE

    TEMPORARY SHORING DURING CONSTRUCTION. THE SHORING SHALL NOT BE REMOVED UNTIL THE SUPPORTING ELEMENTS

    ARE IN PLACE, THE CONCRETE IN THE WALLS AND SUPPORTING ELEMENTS HAS ATTAINED THE SPECIFIED 28 DAY

    COMPRESSIVE STRENGTH (FC') AND COMPACTION OF THE BACKFILL HAS BEEN COMPLETED.

    8. RETAINING WALLS AND/OR EXPOSED CONCRETE WALLS SHALL HAVE CONTROL JOINTS AT 10 FEET AND EXPANSION

    JOINTS AT 30 FEET MAXIMUM ON CENTERS UNLESS NOTED OTHERWISE. WALLS WITH INTEGRAL COLUMN PIERS OR

    PILASTERS SHALL HAVE A FORMED CONTROL JOINT ON ONE SIDE OF EACH PIER ON THE EXPOSED FACE OF THE WALL.

    JOINTS SHALL BE FILLED WITH AN APPROVED SEALANT.

    9. EXCEPT WHERE OTHERWISE NOTED, SHALL BE 4" THICK CONCRETE REINFORCED WITH 6X6 W1.4XW1.4WELDED WIRE

    FABRIC. LAP MESH 6" IN EACH DIRECTION. PLACING, LAP, ETC. TO CONFORM TO WRI STANDARDS. SLAB ON GRADE SHALL BE

    UNDERLAID BY A MINIMUM OF 4 INCHES OF GRANULAR MATERIAL HAVING A MAXIMUM AGGREGATE SIZE OF 1.5 INCHES AND

    NOT MORE THAN 10% OF MATERIAL PASSING THROUGH A NO. 4 SIEVE. PRIOR TO PLACING THE GRANULAR MATERIAL, THE

    FLOOR SUBGRADE SHALL BE PROPERLY COMPACTED, PROOFROLLED, FREE OF STANDING WATER, MUD AND FROZEN SOIL.

    BEFORE PLACEMENT OF THE CONCRETE, A 10 MIL POLYETHYLENE VAPOR BARRIER SHALL BE PLACED ON TOP OF THE

    GRANULAR MATERIAL.

    FOR ALL EXTERIOR SLABS ON GRADE, AIR ENTRAINED CEMENT WITH ENTRAINED AIR OF 6%±1.5% OR EQUIVALENT AIR

    ENTRAINING AGENT SHALL BE USED.

    PROVIDE 1/2" PERIMETER EXPANSION JOINT FILLED WITH COMPRESSIVE MATERIAL WHERE SLABS ABUT VERTICAL SURFACES.

    10. SLABS ON GRADE SHALL HAVE CONSTRUCTION JOINTS OR CRACK CONTROL JOINTS AT EACH COLUMN LINE IN EACH

    DIRECTION. PROVIDE ADDITIONAL JOINTS WITH A MAXIMUM SPACING NOT TO EXCEED 36 TIMES THE SLAB THICKNESS.

    ARRANGE JOINTS SUCH THAT PANEL LENGTH TO WIDTH RATIOS DOES NOT EXCEED 1.5. PROVIDE 3/4" DIAMETER X 1'(4"

    SMOOTH DOWELS AT 12 INCHES ON CENTER AT SLAB ON GRADE CONSTRUCTION JOINTS.

    13. WHERE THE SLAB IS TO RECEIVE SENSITIVE ARCHITECTURAL FLOOR FINISHES, SUCH AS CERAMIC TILE, ALL JOINTS IN

    THE SLAB CONSTRUCTION SHALL BE PLACED TO ALIGN WITH JOINTS IN THE FINISHED MATERIAL.

    D. CONCRETE

    1. CONCRETE SHALL HAVE NATURAL SAND FINE AGGREGATE AND NORMAL WEIGHT COARSE AGGREGATES CONFORMING

    TO ASTM C33, TYPE I PORTLAND CEMENT CONFORMING TO ASTM C150, AND SHALL HAVE A COMPRESSIVE STRENGTH (FC') OF

    3000 PSI AT 28 DAYS, EXCEPT SLAB ON GRADE TO BE 3,500 PSI. ALL CONCRETE EXPOSED TO WEATHER SHALL BE AIR

    ENTRAINED 6%±1.5%. ALL STRUCTURAL CONCRETE HAS BEEN DESIGNED BY THE ULTIMATE STRENGTH METHOD AND IN

    ACCORDANCE WITH THE PROVISIONS OF ACI 318.

    2. GROUND GRANULATED BLAST(FURNACE SLAG MAY BE USED AS A POZZOLAN TO REPLACE A PROTION OF THE

    PORTLAND CEMENT IN A CONCRETE MIX, SUBJECT TO THE APPROVAL OF THE STRUCTURAL ENGINEER. GROUND

    GRANULATED BLAST(FURNACE SLAG WHEN USED, SHALL CONFORM TO ASTM C989. CONCRETE MIXES USING GROUND

    GRANULATED BLAST(FURNACE SLAG SHALL BE PROPORTIONED TO ACCOUNT FOR THE PROPERTIES OF THE SPECIFIC

    GROUND GRANULATED BLAST(FURNACE SLAG USED. THE RATIO OF THE AMOUNT OF THE GROUND GRANULATED

    BLAST(FURNACE SLAG TO THE TOTAL AMOUNT OF GROUND GRANULATED BLAST(FURNACE SLAB AND CEMENT IN THE MIX

    SHALL NOT EXCEED 40 PERCENT.

    3. GROUT FOR BASE PLATES SHOULD BE NON(SHRINKABLE, NON(METALLIC CONFORMING TO ASTM C827 AND SHALL HAVE

    A SPECIFIED COMPRESSIVE STRENGTH AT 28 DAYS OF 5,000 PSI. PRE(GROUTING OF BASE PLATES WILL NOT BE PERMITTED.

    4. ALL CONCRETE WORK AND SHALL COMPLY WITH THE REQUIREMENTS OF THE ACI BUILDING CODE (ACI 318), AND THE

    SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301).

    5. DETAILING OF CONCRETE REINFORCEMENT BARS AND ACCESSORIES SHALL CONFORM TO THE RECOMMENDATIONS OF

    ACI 315 "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT" AND ACI SP(66 "DETAILING MANUAL". PLACING OF

    REINFORCING BARS SHALL CONFORM TO THE RECOMMENDATIONS OF ACI 315R "MANUAL OF ENGINEERING AND PLACING

    DRAWINGS FOR REINFORCED CONCRETE STRUCTURES" AND CRSI "MANUAL OF STANDARD PRACTICE".

    6. MIXING, TRANSPORTING, AND PLACING OF CONCRETE SHALL CONFORM TO ACI 301.

    7. MINIMUM CONCRETE COVER PROTECTION FOR REINFORCEMENT BARS SHALL BE AS FOLLOWS: (SEE ACI 318 SECTION

    7.7 FOR CONDITIONS NOT NOTED)

    FOOTINGS2222222222222222222 .3 INCHES

    SLABS ON GRADE 2222222222....2 .2 INCHES (TOP)

    WALLS BELOW GRADE (BACKFILLED SIDE) 2.....2.2 INCHES

    WALLS BELOW GRADE (NO BACKFILL) 2..........2...3/4 INCHES

    8. PROVIDE STANDARD BAR CHAIRS AND SPACERS AS REQUIRED TO MAINTAIN CONCRETE PROTECTION SPECIFIED.

    9. CONCRETE REINFORCEMENT BARS SHALL CONFORM TO ASTM A615, GRADE 60. REINFORCEMENT BARS SHALL NOT BE

    TACK WELDED, WELDED, HEATED OR CUT UNLESS INDICATED ON THE CONTRACT DOCUMENTS OR REVIEWED BY THE

    STRUCTURAL ENGINEER.

    10. WELDED WIRE FABRIC SHALL CONFORM TO ATSM A185. FABRIC SHALL BE SUPPLIED IN FLAT SHEETS. FABRIC SHALL BE

    LAPPED A MINIMUM OF 6 INCHES.

    11. WELDING OF REINFORCEMENT BARS, WHEN ACCEPTED BY THE STRUCTURAL ENGINEER, SHALL CONFORM TO THE

    AMERICAN WELDING SOCIETY STANDARD D1.4. ELECTRODES FOR SHOP AND FIELD WELDING OF REINFORCEMENT BARS

    SHALL CONFORM TO ASTM A233, CLASS E90XX.

    12. REINFORCEMENT DESIGNATED AS "CONTINUOUS" SHALL LAP 48 BAR DIAMETERS AT SPLICES UNLESS NOTED

    OTHERWISE. REINFORCEMENT BAR SPLICES IN GRADE BEAMS SHALL BE LOCATED AT THE CENTERLINE OF SUPPORTS FOR

    BOTTOM BARS AND AT MIDSPAN FOR TOP BARS. PROVIDE STANDARD ACI HOOKS FOR TOP AND BOTTOM BARS AT

    DISCONTINUOUS ENDS OF ALL GRADE BEAMS.

    13. HORIZONTAL FOOTING AND HORIZONTAL WALL REINFORCEMENT SHALL BE CONTINUOUS AND SHALL HAVE 90(DEGREE

    BENDS AND EXTENSIONS, OR CORNER BARS OF EQUIVALENT SIZE LAPPED 36 BAR DIAMETERS, AT CORNERS AND

    INTERSECTIONS.

    14. HORIZONTAL JOINTS WILL NOT BE PERMITTED IN CONCRETE CONSTRUCTION EXCEPT AS SHOWN ON THE CONTRACT

    DOCUMENTS. VERTICAL JOINTS SHALL OCCUR AT CENTER OF SPANS AT LOCATIONS REVIEWED BY THE STRUCTURAL

    ENGINEER.

    15. CONSTRUCTION JOINTS BETWEEN PIERS AND PIER CAPS, FOOTINGS AND WALLS OR COLUMNS, OR WALLS, COLUMNS,

    BEAMS AND THE FLOOR SYSTEM THEY SUPPORT SHALL BE PREPARED BY ROUGHENING THE CONTACT SURFACE TO A FULL

    AMPLITUDE OF APPROXIMATELY 1/4 INCH LEAVING THE CONTACT SURFACE CLEAN AND FREE OF LAITANCE.

    16. CONCRETE STRENGTH, PROPORTIONS AND TESTING SHALL MEET THE FOLLOWING REQUIREMENTS:

    a. CONCRETE STRENGTH SHALL NOT BE LESS THAN STRENGTHS LISTED ABOVE AT 28 DAYS.

    b. THE MIX DESIGN SHALL BE PREPARED BY AN INDEPENDENT TESTING LABORATORY APPROVED BY THE OWNER USING

    MATERIALS TO BE USED ON THE JOB. THE LABORATORY MIX DESIGN SHALL EXCEED THE DESIRED JOB STRENGTH OF

    CONCRETE BY 1,200 PSI. FOUR COPIES OF MIX DESIGN SHALL BE SUBMITTED TO THE OWNER BEFORE CONCRETE WORK HAS

    BEGUN.

    C. SLUMP SHALL NOT EXCEED 4 INCHES.

    D. ALL COSTS OF CONCRETE TESTING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. TESTING OF CONCRETE SHALL

    BE ACCOMPLISHED BY TAKING FOUR STANDARD TEST CYLINDERS OF THE CONCRETE FOR EACH DAY CONCRETE IS POURED.

    ONE SET OF TEST CYLINDERS MAY REPRESENT NO MORE THAN 55 CUBIC YARDS OF CONCRETE NOR ONE DAY'S POUR.

    CYLINDERS SHALL BE BROKEN TWO AT 7 DAYS AND TWO AT 28 DAYS IN ACCORDANCE WITH ASTM SPECIFICATIONS. FOR ALL

    CONCRETE, SLUMP CONE TEST SHALL BE RUN AT THE JOB SITE ON EACH TRUCK DELIVERY. CONCRETE USED FOR SLUMP

    CONE TEST SHALL NOT BE TAKEN FROM FIRST OR LAST 15% OF EACH LOAD. ALL TEST CYLINDERS AND SLUMP CONE TESTS

    SHALL BE PERFORMED BY A QUALIFIED TECHNICIAN FROM AN APPROVED TESTING FIRM IF DIFFERENT FROM GEOTECHNICAL

    ENGINEERS USED TO MONITOR SITE GRADING.

    31. THE FOLLOWING ENVIRONMENTAL REQUIREMENTS SHALL BE MET AND MAINTAINED:

    A. PROVIDE COLD WEATHER AND/OR HOT WEATHER PROTECTION AS RECOMMENDED IN ACI 306 AND ACI 305.

    B. UNLESS ADEQUATE PROTECTION IS PROVIDED, CONCRETE SHALL NOT BE PLACED DURING RAIN, SLEET OR SNOW.

    PROTECT CONCRETE FROM RAIN WATER, MAINTAIN CONCRETE WATER RATIO AND PROTECT CONCRETE SURFACE.

    C. ALL CONCRETE SHALL BE ADEQUATELY PROTECTED AFTER POURING TO PREVENT DAMAGE FROM FREEZING, BY THE USE

    OF SUITABLE COVERS AND ADEQUATE HEATING EQUIPMENT. FROZEN AND DAMAGED CONCRETE MUST BE REMOVED

    AND REPLACED AT THE CONTRACTOR'S EXPENSE. DO NOT PLACE CONCRETE ON FROZEN EARTH.

    D. ADMIXTURES TO RETARD OR ACCELERATE SETTING, REDUCE WATER RATIO OR PREVENT FREEZING SHALL NOT BE USED

    WITHOUT PRIOR APPROVAL FROM TENANT. NO ADMIXTURES CONTAINING CALCIUM CHLORIDE MAY BE USED.

    E. DO NOT PLACE CONCRETE WHEN TEMPERATURE IS 40 DEGREES F. AND FALLING OR WHEN FREEZING WEATHER IS

    PREDICTED WITHIN 24 HOURS. "RECOMMENDED PRACTICE FOR WINTER CONCRETING", ACI 604, MAY BE FOLLOWED FOR

    PLACING CONCRETE IN COLD WEATHER.

    F. NO CALCIUM CHLORIDE OR OTHER ACCELERATORS OR ANTI(FREEZES SHALL BE USED.

    E. ROOF DECK

    1. ROOF DECK SHALL BE RIGID INSULATION BOARD ON PAINTED TYPE B ROOF DECK. TYPE B DECK SHALL BE 22 GAGE

    COLD FORMED STEEL CONFORMING TO ASTM A653 SQ GRADE 33. METAL DECK SHALL BE 1(1/2 INCHES DEEP WITH A MINIMUM

    SECTION MODULUS (SP) OF 0.186 INCHES CUBED PER FOOT OF WIDTH.

    2. PROPERTIES AND ALLOWABLE STRESSES OF STEEL ROOF DECKS SHALL BE BASED ON THE AISI "SPECIFICATION FOR

    THE DESIGN OF COLD(FORMED STEEL STRUCTURAL MEMBERS".

    3. PLUG WELD DECK TO SUPPORTING STEEL AND ADJOINING DECK SHEETS IN ACCORDANCE WITH THE

    RECOMMENDATIONS OF THE AMERICAN WELDING SOCIETY STANDARD D1.3. 30 INCH WIDE DECK SHEETS SHALL BE WELDED

    AT END LAPS AND END SUPPORTS USING A 12(6(12 PATTERN (A WELD AT EACH SIDE LAP AND AT THE THIRD AND FOURTH

    FLUTES), AND WELDED AT INTERMEDIATE SUPPORTS USING A 12(18 STAGGERED PATTERN (A WELD AT EACH SIDE LAP AND AT

    THIRD OR FOURTH FLUTES). 36 INCH WIDE DECK SHEETS SHALL BE WELDED AT END LAPS, END SUPPORTS AND

    INTERMEDIATE SUPPORTS USING 4 WELDS PER SHEET (A WELD AT EACH SIDE LAP AND AT EVERY OTHER FLUTE). DECK

    SHEETS SHALL BE WELDED AT EACH VALLEY AND 12 INCHES O.C. ALONG SIDE LAPS TO ALL SUPPORTS WITHIN 6 FEET FROM

    THE INSIDE FACE OF THE PERIMETER WALL. SIDE LAPS BEYOND 6 FEET FROM THE INSIDE FACE OF THE PERIMETER WALL

    SHALL BE FASTENED TOGETHER WITH ATTACHMENTS AT MIDSPAN BETWEEN JOISTS. PROVIDE ADDITIONAL DECK WELDS AS

    SHOWN ON THE DRAWINGS.

    4. USE WELDING WASHERS ON ALL CONNECTIONS OF STEEL DECK WITH METAL THICKNESS LESS THAN 22 GA. TO

    STRUCTURAL STEEL SUPPORTS CONCRETE.

    F. STRUCTURAL STEEL

    1. ALL STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH THE LATEST AISC CODE. ALL

    WIDE FLANGE SHAPES SHALL BE ASTM A992/A572 GRADE 50. ALL OTHER STRUCTURAL STEEL SHALL BE ASTM A36 UNO.

    A. ALL STEEL RECTANGULAR/SQUARE HOLLOW STRUCTURAL SECTIONS SHALL BE ASTM A500 GRADE B, FY=46 KSI.

    B. ALL STEEL PIPE SECTIONS SHALL BE ASTM A501 OR ASTM A53, TYPE E OR S GRADE B.

    C. ALL STEEL SHALL HAVE A SHOP COAT OF RUST INHIBITIVE PAINT.

    D. ALL STEEL SHALL BE THOROUGHLY CLEANED IN ACCORDANCE WITH SSPC( SP3 PRIOR TO PAINTING.

    2. ANCHOR BOLTS SHALL CONFORM TO ASTM F1554, GRADE 36, UNLESS NOTED OTHERWISE.

    3. CONNECTION BOLTS FOR STRUCTURAL STEEL MEMBERS SHALL BE HIGH STRENGTH BOLTS WHICH MEET OR EXCEED

    THE REQUIREMENTS OF ASTM A325, TYPE N, X, OR F. BOLTS SHALL BE DESIGNED AS BEARING TYPE BOLTS, EXCEPT AS

    NOTED. BOLTS SHALL BE INSTALLED IN ACCORDANCE WITH THE "SNUG TIGHT" CONDITION AS OUTLINED IN THE

    "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS". BOLTS SHALL HAVE A HARDENED WASHER

    PLACED UNDER THE ELEMENT TO BE TIGHTENED. BOLTS IN BRACING CONNECTIONS, MOMENT CONNECTIONS OR OTHER

    CONNECTIONS NOTED ON THE DRAWINGS SHALL BE CONSIDERED TO BE "SLIP CRITICAL" BOLTS, AND SHALL BE DESIGNED AS

    FRICTION TYPE BOLTS. FRICTION TYPE CONNECTIONS SHALL BE TIGHTENED BY THE USE OF THE TURN(OF(THE(NUT METHOD

    OR THE USE OF LOAD INDICATING TYPE BOLTS, INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S

    RECOMMENDATIONS.

    4. STRUCTURAL STEEL DETAILING, FABRICATION AND ERECTION SHALL CONFORM TO THE AISC "SPECIFICATION FOR

    STRUCTURAL STEEL BUILDINGS" AND THE AISC "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES".

    5. TYPICAL CONNECTION DETAILS ARE INDICATED ON THE DRAWINGS. THE FABRICATOR SHALL PREPARE THE SHOP

    DRAWINGS FOR THE PROJECT BASED ON THIS CONNECTION DESIGN INFORMATION. IF ALTERNATE CONNECTION DESIGNS

    ARE USED, THE FABRICATOR SHALL HAVE A REGISTERED PROFESSIONAL ENGINEER PREPARE THE CONNECTION DESIGNS.

    SUCH DESIGNS SHALL BE SUBMITTED WITH THE SHOP DRAWINGS AND SHALL BEAR THE SEAL OF THIS RESPONSIBLE

    PROFESSIONAL ENGINEER. THE FABRICATOR IS RESPONSIBLE FOR THE SELECTION, DESIGN AND DETAILING OF ALL

    CONNECTIONS NOT FULLY DETAILED ON THE CONTRACT DRAWINGS. CONNECTIONS SHALL BE DESIGNED AND DETAILED IN

    ACCORDANCE WITH THE AISC "MANUAL OF STEEL CONSTRUCTION ", LATEST EDITION. TABLE II AND TABLE III OF PART 4

    SHOULD BE USED. THE END REACTION OF THE CONNECTED BEAM SHALL BE DETERMINED FROM PART 2 "ALLOWABLE LOADS

    ON BEAMS" FOR THE MEMBER SIZE AND SPAN INDICATED, UNLESS A DESIGN REACTION IS INDICATED ON THE PLANS. IN NO

    CASE SHALL THE END REACTION BE TAKEN AS LESS THAN 12.0 KIPS.

    6. STEEL FABRICATOR IS SOLELY RESPONSIBLE FOR SURVEYING AND VERIFICATION OF EXISTING CONDITIONS INCLUDING

    BUT NOT LIMITED TO THE LOCATION, ELEVATION, AND DIMENSIONS OF EXISTING WALLS AND FRAMING.

    7. PRIOR TO DETAILING CONNECTIONS FOR STRUCTURAL STEEL, THE STEEL FABRICATOR SHALL SUBMIT FOR APPROVAL

    REPRESENTATIVE DETAILS AND CALCULATIONS FOR EACH TYPE OF STRUCTURAL STEEL CONNECTION TO BE UTILIZED.

    AFTER APPROVAL, THE CONNECTIONS MAY BE INCORPORATED INTO THE SHOP DRAWINGS, ALONG WITH A TABLE OF DESIGN

    CAPACITIES FOR THE RANGE OF CONNECTIONS TO BE USED.

    8. WELDING SHALL CONFORM TO THE AMERICAN WELDING SOCIETY STANDARD D1.1. ELECTRODES FOR SHOP AND FIELD

    WELDS SHALL CONFORM TO AWS A5.1 OR AWS A5.5, CLASS E70XX, LOW HYDROGEN.

    9. ALL SHOP AND FIELD WELDING SHALL BE PERFORMED BY WELDERS CERTIFIED, AS DESCRIBED IN "AMERICAN WELDING

    SOCIETY'S STANDARD QUALIFICATION PROCEDURE", AWS D1.1, TO PERFORM THE TYPE OF WORK REQUIRED.

    10. SPLICING OF STRUCTURAL STEEL MEMBERS WHERE NOT DETAILED ON THE CONTRACT DOCUMENTS IS PROHIBITED

    WITHOUT THE PRIOR APPROVAL OF THE STRUCTURAL ENGINEER AS TO LOCATION, TYPE OF SPLICE AND CONNECTION TO BE

    MADE.

    11. THE CONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER OF ANY MISFABRICATED STRUCTURAL STEEL PRIOR TO

    ERECTION OF SAME.

    12. PENETRATIONS SHALL NOT BE CUT IN STRUCTURAL STEEL MEMBERS UNLESS SO INDICATED IN THE DRAWINGS OR AS

    REVIEWED BY THE ENGINEER.

    13. HEADED CONCRETE ANCHORS SHALL BE NELSON OR KSM HEADED CONCRETE ANCHORS (OR ACCEPTABLE EQUAL),

    AND SHALL CONFORM TO ASTM A108, GRADES C(1010 THROUGH C(1020. ANCHORS SHALL BE AUTOMATICALLY END WELDED

    WITH SUITABLE STUD WELDING EQUIPMENT IN THE SHOP OR IN THE FIELD. WELDING SHALL BE IN ACCORDANCE WITH THE

    RECOMMENDATIONS OF THE NELSON STUD WELDING COMPANY OR THE KSM WELDING SYSTEMS COMPANY.

    14. STEEL MEMBERS, FABRICATIONS AND ASSEMBLIES INDICATED ON THE DRAWINGS TO BE GALVANIZED SHALL BE

    GALVANIZED AFTER FABRICATION BY HOT DIP PROCESS IN ACCORDANCE WITH ASTM A123. WEIGHT OF ZINC COATING TO

    CONFORM TO THE REQUIREMENTS SPECIFIED UNDER "WEIGHT OF COATING" IN ASTM A123 OR ASTM A386, AS APPLICABLE.

    15. ALL LINTELS AND SHELF ANGLES SHALL BE HOT DIP GALVANIZED

    16. ANY POINTS OF WELDING SHALL BE TOUCHED UP IN THE FIELD WITH A ZINC(RICH PAINT BY THE STEEL ERECTOR.

    G. JOISTS

    1. OPEN WEB STEEL JOISTS AND BRIDGING FOR JOISTS SHALL CONFORM TO THE STEEL JOIST INSTITUTE "STANDARD

    SPECIFICATIONS FOR OPEN WEB STEEL JOISTS". ERECTION LAYOUT, CALCULATIONS, DETAILS, AND ANY OTHER

    INFORMATION DEEMED NECESSARY BY THE ENGINEER SHALL BE SUBMITTED FOR REVIEW PRIOR TO FABRICATION. TOP

    CHORDS SHALL BE ANGLES OR TEES. JOISTS SHALL BE WELDED TO SUPPORTING STEEL MEMBERS. WHERE COLUMNS ARE

    NOT FRAMED IN AT LEAST TWO DIRECTIONS WITH STEEL BEAMS OR JOIST GIRDERS, THE JOIST AT THE COLUMN LINE SHALL

    BE BOLTED TO SUPPORTING MEMBERS DURING ERECTION. BRIDGING SHALL BE CONTINUOUS THROUGH OPEN WEB STEEL

    JOISTS AND BE ANCHORED TO SPANDREL MEMBERS. PROVIDE DIAGONAL BRIDGING WITH BOLTED CONNECTIONS AT

    CHORDS AND INTERSECTIONS WHERE REQUIRED BY SJI. CAMBER ALL JOISTS THE AMOUNT RECOMMENDED BY THE SJI.

    OPEN WEB STEEL JOISTS MARKED "SPECIAL" OR "SP" SHALL BE DESIGNED BY THE JOIST MANUFACTURER TO SUPPORT THE

    DEAD AND LIVE UNIFORM AND CONCENTRATED LOADS AND/OR NET UPLIFT LOADS NOTED IN THE DRAWINGS.

    2. DESIGN ALL JOISTS FOR NET UPLIFT OF 10 PSF, UNLESS NOTED OTHERWISE ON THE PLANS.

    3. ALL JOISTS SHALL HAVE A SHOP COAT OF RUST INHIBITIVE NON(BITUMINOUS PAINT.

    4. STEEL JOISTS SHALL BE DESIGNED, FABRICATED AND ERECTED TO THE REQUIREMENTS OF THE SPECIFICATIONS OF

    THE STEEL JOIST INSTITUTE FOR SERIES K JOISTS

    MANUFACTURER SHALL BE A MEMBER OF THE STEEL JOIST INSTITUTE. ALL BRIDGING SHALL BE IN ACCORDANCE WITH SJI

    STANDARDS UNLESS NOTED OTHERWISE IN THE DRAWINGS.

    H. MASONRY

    1. MASONRY UNITS SHALL BE TYPE:

    A. ASTM C90 SOLID OR ASTM C90 HOLLOW GROUTED SOLID BELOW GRADE.

    B. ASTM C90 HOLLOW ABOVE GRADE

    C. WITH MINIMUM COMPRESSIVE STRENGTH OF 1900 PSI

    D. ALL CMU SHALL BE LAID IN A FULL BED OF MORTAR.

    2. FOLLOWING ARE THE BLOCK STRENGTHS REQUIRED:

    A. ASTM C90 SOLID 1900 PSI ON GROSS AREA OF INDIVIDUAL UNITS.

    B. ASTM C90 HOLLOW 1900 PSI ON NET AREA OF INDIVIDUAL UNITS.

    3. ALL MORTAR SHALL BE ASTM C270 TYPE S.

    4. GROUT SHALL BE A HIGH SLUMP MIX

    A. IN ACCORDANCE WITH ASTM SPECIFICATION C476

    B. HAVING A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI.

    C. FROM FIELD OBTAINED TEST CYLINDERS.

    5. LAID UP MASONRY DESIGN F'M IS 1350 PSI FOR STANDARD CONCRETE MASONRY.

    6. ALL CONCRETE MASONRY SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE "BUILDING CODE REQUIREMENTS FOR

    MASONRY STRUCTURES ACI 530/ASCE 5/TMS 402" AND "SPECIFICATIONS FOR MASONRY STRUCTURES ACI 530.1/ASCE 6/TMS

    602.

    A. AND INSPECTED BY A QUALIFIED ENGINEER.

    7. ALL BRICK MASONRY UNITS SHALL BE GRADE SW IN ACCORDANCE WITH ASTM C216 WITH A MINIMUM COMPRESSIVE

    STRENGTH OF 3000 PSI AND BONDED TOGETHER WITH TYPE S MORTAR.

    8. PROVIDE HOT(DIPPED GALVANIZED TRUSS TYPE HORIZONTAL JOINT REINFORCEMENT, MIN. 9 GA, AT 16" ON CENTER

    VERTICAL IN ALL MASONRY WALLS. SPACE HORIZONTAL JOINT REINFORCEMENT AT 8 INCHES ON CENTER IN ALL PARAPETS.

    USE SHOP FABRICATED SPECIAL PIECES AT ALL CORNERS AND TEES.

    9. PROVIDE 1(#5 VERTICAL AT EACH END, CORNER AND INTERSECTION OF ALL WALLS.

    10. PROVIDE MASONRY ACCESSORIES TO SECURE VERTICAL REINFORCEMENT IN PLACE AND CORRECTLY POSITIONED.

    VERTICAL REINFORCEMENT IS TO BE CENTERED IN THE MASONRY CELLS UNLESS INDICATED OTHERWISE.

    11. CELLS TO BE GROUTED SHALL BE CLEAN AND FREE OF EXCESS MORTAR AND FOREIGN MATERIALS.

    12. LINTELS SHALL BEAR ON MASONRY WALLS A MINIMUM OF 8" AT EACH END. FOR CMU WALLS, PROVIDE TWO GROUTED

    CORES EACH SIDE OF OPENING FULL HEIGHT OF WALL AND REINFORCE EACH OF THE TWO GROUTED CORES WITH 1(#5

    VERTICAL EXTENDING FROM THE FOUNDATION TO THE POINT OF LATERAL SUPPORT FOR THE WALL ABOVE THE LINTEL

    LOCATION. UNLESS NOTED OTHERWISE, THE FOLLOWING LINTELS MAY BE USED WHEN THE HEAD OF THE MASONRY

    OPENING IS BELOW FLOOR OR ROOF BEARING ELEMENTS BY A MINIMUM DISTANCE OF 75% OF THE LINTEL SPAN:

    Galvanized Steel CMU Lintel Precast Concrete Lintel

    Span Angle Lintel per per 4" CMU wythe per 4" CMU Wythe

    4" Masonry wythe (fm'= 1500 psi) (fc'= 3000 psi)

    0 ( 4'(0" L3(1/2 x 3(1/2 x 1/4 8" Deep w/ (1) 1#4 8" Deep w/ (1) #4

    Bottom Top & Bottom

    4'(1" ( 6'(0" L5 x 3(1/2 x 5/16 8" Deep w/ (1) #5 8" Deep w/ (1) #4

    Bottom Top & Bottom

    6'(1" ( 8'(0" L5 x 3(1/2 x 3/8 16" Deep w/ (1) #4 8" Deep w/ (1) #4

    Bottom Top & Bottom

    8'(1" ( 12'(0" L6 x 3(1/2 x 1/2 16" Deep w/ (1) #5 8" Deep w/ (1) #5

    Bottom Top & Bottom

    13. TEMPORARY SHORING OF LINTELS MUST BE PROVIDED UNTIL MASONRY HAS CURED. CONTROL JOINTS IN MASONRY

    SHALL NOT BE LOCATED WITHIN A DISTANCE EQUAL TO 50% OF THE LINTEL SPAN ADJACENT TO EACH SIDE OF THE OPENING.

    14. HORIZONTAL JOINT REINFORCEMENT SHALL BE USED IN THE MASONRY CONSTRUCTION. SUCH JOINT REINFORCEMENT

    SHALL BE PLACED AT 8 INCHES ON CENTER VERTICALLY IN WALLS BELOW GRADE AND AT 16 INCHES ON CENTER VERTICALLY

    IN WALLS THAT ARE ABOVE GRADE. HORIZONTAL JOINT REINFORCEMENT SHALL BE FABRICATED FROM GALVANIZED

    COLD(DRAWN STEEL WIRE CONFORMING TO ASTM A82. REINFORCEMENT SHALL CONSIST OF TWO OR MORE SMOOTH OR

    DEFORMED LONGITUDINAL WIRES NO. 9 GAGE OR LARGER, WELD CONNECTED WITH NO. 12 GAGE OR LARGER CROSS WIRES.

    GALVANIZE COATING SHALL CONFORM TO ASTM A116 AND SHALL BE APPLIED AT A WEIGHT OF NOT LESS THAN 1.5 OUNCES

    PER SQUARE FOOT OF UNCOATED WIRE SURFACE. THE OUT(TO(OUT SPACING OF THE LONGITUDINAL WIRES SHOULD BE

    1(5/8 INCHES LESS THAN THE WIDTH OF THE MASONRY UNITS. THE DISTANCE BETWEEN THE WELDED CONTACTS OF THE

    CROSS WIRES WITH EACH LONGITUDINAL WIRE SHOULD NOT EXCEED 6 INCHES AND 16 INCHES FOR SMOOTH AND DEFORMED

    LONGITUDINAL WIRES RESPECTIVELY.

    15. CONTROL JOINTS SHALL BE PLACED IN THE MASONRY CONSTRUCTION SUCH THAT THE PANEL LENGTH TO HEIGHT

    RATIO OF THE WALL DOES NOT EXCEED 2.5, AND THAT THE MAXIMUM PANEL LENGTH OF WALL DOES NOT EXCEED 25 FEET.

    ADDITIONAL JOINTS SHALL BE PLACE WHERE ABRUPT CHANGES IN WALL SECTIONS OCCUR.

    16. MASONRY CONSTRUCTION SHALL BE INSPECTED DURING THE VARIOUS WORK STAGES BY A QUALIFIED INSPECTOR.

    INSPECTION SHALL INCLUDE CHECKING FOR COMPLIANCE WITH PROJECT DRAWINGS AND SPECIFICATIONS, INCLUDING

    RECORDING OF THE FOLLOWING:

    I. QUALITY AND TESTING OF MASONRY UNITS AND MATERIALS FOR MORTAR, GROUT, AND MAKING OF PRISMS WHEN

    REQUIRED.

    II. PROPORTIONING, MIXING, AND CONSISTENCY OF MORTAR AND GROUT.

    III. LAYING, MORTARING, AND GROUTING OF MASONRY UNITS AND ELEMENTS.

    IV. CONDITION, GRADE, SIZE, SPACING AND PLACEMENT OF REINFORCEMENT.

    V. SIGNIFICANT OR UNUSUAL CONSTRUCTION LOADS ON MASONRY STRUCTURAL ELEMENTS.

    VI. WHEN AMBIENT TEMPERATURE FALLS BELOW 40 DEGREES F OR RISES ABOVE 100 DEGREES F, A COMPLETE RECORD

    OF WEATHER CONDITIONS AND OF PRECONDITIONING AND PROTECTION GIVEN TO MASONRY MATERIALS, AND PROTECTION

    AND CURING OF COMPLETED WORK, SHALL BE MAINTAINED.

    VII. GENERAL PROGRESS OF WORK.

    17. FOR MASONRY WALLS OVER EIGHT FEET IN HEIGHT, PROVIDE CONSTRUCTION BRACING SHOP DRAWINGS AND

    CALCULATIONS SIGNED AND SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE JURISDICTION OF CONSTRUCTION.

    I. DEMOLITION

    ALL WORK SHALL BE IN GENERAL COMPLIANCE WITH THE APLICABLE CODE.

    FURNISH ALL LABOR AND MATERIALS NECESSARY TO PERFORM THE DEMOLITION WORK IN A COMPLETED MANNER SUCH

    THAT NEW WORK CAN BE INSTALLED WITH MINIMUM PREPARATION

    CONTRACTOR SHALL INCLUDE IN THE SCOPE OF WORK ALL ASPECTS OF REQUIRED DEMOLITION, SHORING OF EXISTING

    STRUCTURE, STAGING THE REPAIR TASKS AND SCHEDULING THE WORK IN A MANNER APPROVED BY THE BUILDING

    MANAGEMENT, CLEAN UP AFTER PORTIONS OF WORK ARE PERFROMED AND CLEAN UP AFTER THE ENTIRE REPAIR IS

    COMPLETED.

    THE CONTRACTOR SHALL TAKE PRECAUTIONS TO PREVENT DAMAGE OF THE EXISTING STRUCTURE. IN THE EVENT OF

    DAMAGE, CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AND CONTACT THE STRUCTURAL ENGINEER FOR

    ASSESSMENT OF THE DAMAGE.

    SCHEDULE ALL WORK IN A CAREFUL MANNER WITH ALL NECESSARY CONSIDERATION FOR FACILITY OPERATIONS, AND

    FACILITY PERSONNEL. ANY DAMAGE TO PERSON OR PROPERTY AS A RESULT OF DEMOLITION AND RELATED WORK SHALL BE

    THE RESPONSIBILITY OF THE CONTRACTOR.

    ERECT BARRIER FENCES, GUARD RAILS, WARNING DEVICES AND SHORING TO PROTECT PERSONNEL WORKING IN THE AREA.

    SUBMIT PROCEDURES AND SCHEDULE PROPOSED FOR THE ACCOMPLISHMENT OF THE DEMOLITION WORK TO THE OWNER

    FOR APPROVAL. INCLUDE SAFE CONDUCT OF THE WORK, DISPOSITION OF MATERIALS, PROTECTION OF REMAINING

    PROPERTY AND COORDINATION WITH OTHER WORK.

    THE CONTRACTOR SHALL TAKE MEASURES TO COORDINATE THE CONSTRUCTION SUCH THAT INTERFERENCE OF EXISTING

    REINFORCING STEEL WITH PLACEMENT OF NEW ANCHORS (DOWELS, EXPANSION BOLTS, ADHESIVE ANCHORS) DOES NOT

    OCCUR. IF EXISTING REINFORCING STEEL IS ENCOUNTERED DURING DRILLING, ADJUST THE ANCHOR LOCATION IF POSSIBLE

    AND NOTIFY THE ENGINEER. ABANDONED HOLES SHALL BE FILLED WITH GROUT. ANCHORS SHALL BE SET WITHIN 3 INCHES

    OF THEIR SPECIFIED LOCATION, BUT AT LEAST 1 INCH FROM ANY ABANDONED HOLE. CARE SHALL BE TAKEN NOT TO BREAK

    OR DAMAGE REINFORCING STEEL DURING DRILLING, UNLESS OTHERWISE DIRECTED BY THE ENGINEER.

    Drawn:

    Checked:

    Scale:

    Constr

    uction D

    ocum

    ents

    for:

    1902 campus commons drivesuite 101

    reston, virginia 20191Tel: 703.476.3900Fax: 703.264.0733www.archinc.com

    Issued

    All

    repro

    duction +

    inte

    llectu

    al pro

    pert

    y r

    ights

    reserv

    ed b

    y A

    rchitectu

    re Incorp

    ora

    ted ©

    2016

    RE

    NO

    VA

    TIO

    N A

    ND

    AD

    DIT

    ION

    AS NOTED

    3930 Pender Drive, Suite175Fairfax, VA 22030(703) 890(5000email: [email protected] No 16745.00

    801 N

    . M

    AIN

    ST

    RE

    ET

    ,B

    RID

    GE

    WA

    TE

    R, V

    A 2

    2181

    T:\

    2016 D

    raw

    ings\D

    esig

    n P

    roje

    cts

    ( S

    K &

    DW

    \16745.0

    0 J

    ohn W

    ayla

    nd E

    S\1

    6745_John W

    ayla

    nd E

    S S

    tructu

    ral M

    odel (R

    evit 1

    6).

    rvt

    1/3

    1/2

    017 9

    :15:5

    4 A

    M

    S0.1

    STRUCTURALNOTES

    Project: 16745.00

    Author

    Checker

    RO

    CK

    ING

    HA

    M C

    O. P

    UB

    LIC

    SC

    HO

    OLS

    JO

    HN

    WA

    YL

    AN

    D E

    S

    BID

    SE

    TB

    ID S

    ET

    BID SET

    02(01(2017

    Revisions

  • DESIGN LOAD SCHEDULE

    COMPONENT

    AR

    EA

    CONCRETE SLAB

    STEEL & JOIST

    CEILING

    COLLATERAL

    SL

    AB

    ON

    GR

    AD

    E

    TOTAL DEAD LOAD

    TOTAL LIVE LOAD

    TOTAL LOAD

    (ALL LOADS SHOWN ARE IN POUNDS PER SQ. FT.)

    ROOF & INSULATION

    65

    !

    !

    !

    15

    80

    180

    100

    WALL COMPONENTS & CLADDING: DESIGN WIND PRESSURES (LB/SQ. FT.)

    100502010

    CORNER (ZONE 5)

    MAIN FIELD (ZONE 4)

    TRIBUTARY AREA(SQ. FT.)

    (INTERNAL PRESSURE COEFFICIENTS, GCpi=±0.18)

    500

    +16.4/!17.4 +15.7/!17.4 +14.1/!15.7 +14.0/!14.1 +12.2/!14.0

    +12.2/!14.0+14.0/!17.2+14.1/!18.6+15.7/20.4+16.4/!21.8

    LATERAL LOAD DESIGN SCHEDULE

    SNOW DESIGN LOAD SCHEDULE

    INTERNATIONAL BUILDING CODE 2012/ASCE 7!10

    WIND LOAD

    SEISMIC LOAD

    INTERNATIONAL BUILDING CODE 2012/ASCE 7!10

    1.0TABLE

    7.3tCTHERMAL FACTOR

    SECTIONANALYSIS PROCEDURE12.8

    SECTION

    1.75

    2

    d

    D1

    DS

    SECTION26.7.3

    SECTION27.4

    FIGURE26.5(1A

    20 PSF

    B

    120

    (

    I

    V

    TABLE

    12.2(1

    12.2(1

    TABLE

    TABLE

    12.2(1

    20.3

    SECTION

    TABLE

    11.6(1 & 11.6(2

    SECTION

    11.4.4

    11.4.40.160g

    0.099g

    B

    D

    C

    R

    (

    S

    (

    S

    S

    DEFLECTION AMPLIFICATION FACTOR

    RESPONSE MODIFICATION FACTOR

    BASIC STRUCTURAL SYSTEM

    SITE CLASSIFICATION

    SEISMIC DESIGN CATEGORY

    (1) SECOND PERIOD SPECTRAL ACCELERATION

    SHORT PERIOD SPECTRAL ACCELERATION

    REFERENCEVALUESYMBOLITEM

    MAXIMUM DESIGN VALUE(WW+LW)

    BASIC WIND SPEED (3 SECOND GUST)

    REFERENCEVALUESYMBOLITEM

    Pg

    P f

    eC

    IMPORTANCE FACTORSNOW LOAD

    1.10TABLE1.5.2

    TABLE7.2

    SECTION7.3

    FIGURE7.1

    1.0

    32.7

    42.5

    I

    SNOW EXPOSURE FACTOR

    FLAT(ROOF SNOW LOAD

    GROUND SNOW LOAD

    REFERENCEVALUESYMBOLITEM

    s

    w

    TABLE

    1.5(2IMPORTANCE FACTOR

    EI

    FIGURE

    22(20.062g

    1.25

    BEARING WALLSYSTEM

    TYPICAL ABBREVIATIONS

    AB

    AFF

    ADDL

    ALT

    ARCH

    BCX

    BO

    BLDG

    BM

    BOT

    BRG

    BSMT

    BTWN

    CL

    CANT

    CMU

    COL

    CONC

    CONN

    CON.

    CTRD

    DIA

    DWG

    EF

    EOD

    EOS

    EW

    EA

    EL

    ELEV

    EMBED

    EQL

    EQUIP

    EWB

    EX

    EXIST

    EXP

    EXT

    FDN

    FIN

    FLR

    FT

    FTG

    GA

    GALV

    HP

    HORIZ

    IF

    IN

    INFO

    INT

    JT

    LP

    LW

    LLH

    LLV

    LWB

    MEP

    MST

    MAX

    MECH

    MEZZ

    MFR

    MIN

    MISC

    NTS

    NW

    o/c

    PL

    PC

    PSF

    PSI

    PTN

    REINF

    REQ'D

    RET'G

    SF

    SOG

    SCHED

    SECT

    SIM

    SPECS

    STIFF

    STRUCT

    SWB

    T&B

    T

    TO

    TOC

    TOS

    TS

    TCELE

    TCERE

    TDS

    THK

    TYP

    UNO

    VIF

    VERT

    WRT

    w/

    WWF

    ANCHOR BOLT

    ABOVE FINISH FLOOR

    ADDITIONAL

    ALTERNATE

    ARCHITECT

    BOTTOM CHORD EXTENSION

    BOTTOM OF

    BUILDING

    BEAM

    BOTTOM

    BEARING

    BASEMENT

    BETWEEN

    CENTERLINE

    CANTILEVER

    CONCRETE MASONRY UNIT

    COLUMN

    CONCRETE

    CONNECTION

    CONTINUOUS

    CENTERED

    DIAMETER

    DRAWING

    EACH FACE

    EDGE OF DECK

    EDGE OF SLAB

    EACH WAY

    EACH

    ELEVATION

    ELEVATOR

    EMBEDMENT

    EQUAL

    EQUIPMENT

    EACH WAY BOTTOM

    EXISTING

    EXISTING

    EXPANSION

    EXTERIOR

    FOUNDATION

    FINISH

    FLOOR

    FEET

    FOOTING

    GAGE

    GALVANIZED

    HIGH POINT

    HORIZONTAL

    INSIDE FACE

    INCHES

    INFORMATION

    INTERIOR

    JOINT

    LOW POINT

    LIGHT WEIGHT

    LONG LEG HORIZONTAL

    LONG LEG VERTICAL

    LONG WAY BOTTOM

    MECHANICAL ELECTRICAL PLUMBING

    METAL STUD TRUSS

    MAXIMUM

    MECHANICAL

    MEZZANINE

    MANUFACTURER

    MINIMUM

    MISCELLANEOUS

    NOT TO SCALE

    NORMAL WEIGHT

    ON CENTER

    PLATE

    PILE CAP

    POUNDS PER SQUARE FOOT

    POUNDS PER SQUARE INCH

    PARTITON

    REINFORCEMENT

    REQUIRED

    RETAINING

    STEP FOOTING

    SLAB ON GRADE

    SCHEDULE

    SECTION

    SIMILAR

    SPECIFICATIONS

    STIFFENER

    STRUCTURAL

    SHORT WAY BOTTOM

    TOP AND BOTTOM

    TOP

    TOP OF

    TOP OF CONCRETE

    TOP OF STEEL

    THICKENED SLAB

    TOP CHORD EXTENSION LEFT END

    TOP CHORD EXTENSION RIGHT END

    TURN DOWN SLAB

    THICK OR THICKENED

    TYPICAL

    UNLESS NOTED OTHERWISE

    VERIFY IN FIELD

    VERT.

    WOOD ROOF TRUSS

    WITH

    WELDED WIRE FABRIC

    EWT EACH WAY TOP

    P/C PRECAST

    PAF POWDER ACTUATED FASTENER

    BP_ BEARING PLATE

    GB_ GRADE BEAM

    K KIP

    K!ft KIP(FEET

    MP_ MASONRY PIER

    NBL NON BEARING LINTEL

    WP WALL PLATE

    WC WET COLUMN

    RO

    OF

    !

    5

    5

    5

    7

    22

    55

    33

    POSITIVE PRESSURE: ACTING TOWARD SURFACE.NEGATIVE PRESSURE: ACTING AWAY FROM SURFACE.CORNER ZONE: WITHIN ? FROM BUILDING CORNERS ALONG NORTH/SOUTH/EAST/WEST FACES.

    NOTE:

    1) ZONE DESIGNATIONS AS PER ASCE7.

    (BASIC SEISMIC RESISTING SYSTEM

    EQUIVALENT LATERAL

    FORCE PROCEDURE

    TABLE

    12.2(1

    MASONRY / CONCRETE LINTEL SCHEDULE

    REINFORCING

    TOP BOTTOM TIES MID BARSREMARKSMARK TTYPE

    TYPE A TYPE B TYPE C

    H

    ML1 7 5/8 (2) #4 (2) #4 NONE NONEA 7 5/8

    ML2 A 7 5/8 (2) #5 (2) #5 NONE NONE7 5/8

    3000 PSI CONCRETE(TYPICAL)

    BOTTOMBARS

    MASONRYUNIT

    TOPBARS

    TIES

    CONCRETEBEAM

    MIDBARS

    BOTTOMBARST T T

    BOTTOMBARS

    1'(

    3 1

    /4"

    2'(

    7 1

    /4"

    2'(

    7 1

    /4"

    2'(

    1 1

    /4"

    9 1

    /4"

    4 5

    /8"

    7 5

    /8" 1

    2 5

    /8"

    15 5

    /8"

    H

    ML3 B 7 5/8 (2) #3 (2) #3 NONE NONE15 5/8

    ML4 B 7 5/8 (2) #5 (2) #5 NONE NONE15 5/8

    33RE: DESIGN LOADSCHEDULE ABOVE!

    ! TABLE15(1I I I

    UNIFORM LOADMINIMUM EQUIVALENT

    OCCUPANCY CATEGORY

    TABLE1.5(1I I I(RISK CATEGORY

    TABLE1.5.2

    1.0(IMPORTANCE FACTOR

    WIND EXPOSURE CATEGORY

    BASE SHEARSECTION

    12.8V

    RISK CATEGORYTABLE

    1.5(1!

    MAPPED SHORT PERIODSPECTRAL ACCELERATIONMAPPED (1) SECOND PERIODSPECTRAL ACCELERATION

    sS

    1S

    0.150g

    I I I

    FIGURE

    22(1

    ORDINARY REINFORCEDMASONRY SHEAR WALLS

    CLASSROOM LL 60 !

    ASSEMBLY LL 100 !

    ADDITION9.2K ( KITCHEN

    Drawn:

    Checked:

    Scale:

    Constr

    uction D

    ocum

    ents

    for:

    1902 campus commons drivesuite 101

    reston, virginia 20191Tel: 703.476.3900Fax: 703.264.0733www.archinc.com

    Issued

    All

    repro

    duction +

    inte

    llectu

    al pro

    pert

    y r

    ights

    reserv

    ed b

    y A

    rchitectu

    re Incorp

    ora

    ted ©

    2016

    RE

    NO

    VA

    TIO

    N A

    ND

    AD

    DIT

    ION

    AS NOTED

    3930 Pender Drive, Suite175Fairfax, VA 22030(703) 890(5000email: [email protected] No 16745.00

    801 N

    . M

    AIN

    ST

    RE

    ET

    ,B

    RID

    GE

    WA

    TE

    R, V

    A 2

    2181

    T:\

    2016 D

    raw

    ings\D

    esig

    n P

    roje

    cts

    ( S

    K &

    DW

    \16745.0

    0 J

    ohn W

    ayla

    nd E

    S\1

    6745_John W

    ayla

    nd E

    S S

    tructu

    ral M

    odel (R

    evit 1

    6).

    rvt

    1/3

    1/2

    017 9

    :15:5

    7 A

    M

    S0.2

    DESIGN TABLES

    Project: 16745.00

    Author

    Checker

    RO

    CK

    ING

    HA

    M C

    O. P

    UB

    LIC

    SC

    HO

    OLS

    JO

    HN

    WA

    YL

    AN

    D E

    S

    BID

    SE

    TB

    ID S

    ET

    BID SET

    02(01(2017

    Revisions

  • INFILL EXISTING OPENINGw/ BRICK & 8" CMURE: ARCH DWGS

    INFILL EXISTINGSLAB DEPRESSION

    EXISTING BEARINGWALL TO BE REMOVEDAFTER ROOF JOISTSARE SHORED

    NEW LOADING DOCK SLABRE: CIVIL DWGS

    TRENCH DRAINRE: CIVIL DWGS

    NEW 5" SLAB

    NEW 5" SLABON GRADE

    EXISTING SLAB ON GRADE

    EXISTING SLAB ON GRADE

    EXISTING SLAB ON GRADE

    EXISTING BEARING WALLMEZZANINE JOISTS & SLABABOVE TO BE REMOVED

    LINE OF TEMPORARYSHORING FOR EXISTINGROOF JOISTS

    LINE OF TEMPORARYSHORING UP TOEXISTING ROOF JOISTS

    4 1/2" SLAB RECESSAT WALK(IN COOLERS

    11'(4"1

    2'(0 3

    /4"

    1" EXP JT 34'(0"

    30'(0"

    1"

    EX

    P J

    T

    1

    S2.1

    2

    S2.1

    2

    S2.1

    3

    S2.1

    4

    S2.1

    14'(4"

    (VIF)

    7'(10 3/8"

    NEW 16"x16" SMPw/ (4) #6 VERT &#2 TIES @ 8" o/c

    EXISTING 16"x16" PIER& CMU WALL TOREMAIN

    NEW 8" CMU WALL

    INFILL EXISTINGOPENINGS

    18'(2" (VIF)

    F26.12

    F26

    .12

    8" CMU w/#3 @ 32" o/c

    8" CMU w/#3 @ 32" o/c

    F50

    F40

    F40

    5

    S2.1

    6

    S2.1

    C1

    C1

    ( (1.00' )

    ( (1.00' )

    GROUT EXISTINGWALL SOLID(8"x24" MINIMUM)

    7

    S2.1

    NEW 5" SLAB ON GRADEREINF w/ 6x6(W1.4xW1.4INFILL PIT w/ STRUCTURALGRADE STYROFOAM (60psi)

    GROUT EXISTINGWALL SOLID(8"x24" MINIMUM)

    GROUT EXISTINGWALL SOLID(8"x24" MINIMUM)

    8

    S2.1

    EXISTING PIER TO BEREMOVED AFTERROOF IS SHORED

    5

    S2.1

    9

    S2.1

    NEW 4" SLAB ON GRADEREINF w/ 6x6(W1.4xW1.4

    10

    S2.1

    11

    S2.1

    NEW 6" DIAMETER CHILLER PIPESRE: MECH DWGSUNDERPIN EXISTING FOOTING

    UNDERPIN EXISTINGFOOTING PERDETAIL 11/S2.2

    AT EXISTING PADS TO BE REMOVEDPATCH SLAB AS REQUIRED w/SIKA TOP SEAL(107 OR APPROVED EQUAL(RE: ARCH DEMO DRAWINGS FORFOR LOCATION & EXTENT (VIF))

    5'(0

    " M

    IN

    ( (4.67' )

    EXISTING SANITARY (VIF)

    BOTTOM OF TANKEL (8'(2"COORDINATE w/ PLUMBING

    4" SANITARY LINEINVERT EL (4'(2"(RE: PLUMBING DWGS)

    ( (3.33' )

    STEP FOOTINGTO MATCH EXISTING

    STEP FOOTINGSTO MATCH EXISTING

    Drawn:

    Checked:

    Scale:

    Constr

    uction D

    ocum

    ents

    for:

    1902 campus commons drivesuite 101

    reston, virginia 20191Tel: 703.476.3900Fax: 703.264.0733www.archinc.com

    Issued

    All

    repro

    duction +

    inte

    llectu

    al pro

    pert

    y r

    ights

    reserv

    ed b

    y A

    rchitectu

    re Incorp

    ora

    ted ©

    2016

    RE

    NO

    VA

    TIO

    N A

    ND

    AD

    DIT

    ION

    AS NOTED

    3930 Pender Drive, Suite175Fairfax, VA 22030(703) 890(5000email: [email protected] No 16745.00

    801 N

    . M

    AIN

    ST

    RE

    ET

    ,B

    RID

    GE

    WA

    TE

    R, V

    A 2

    2181

    T:\

    2016 D

    raw

    ings\D

    esig

    n P

    roje

    cts

    ( S

    K &

    DW

    \16745.0

    0 J

    ohn W

    ayla

    nd E

    S\1

    6745_John W

    ayla

    nd E

    S S

    tructu

    ral M

    odel (R

    evit 1

    6).

    rvt

    1/3

    1/2

    017 9

    :16:0

    0 A

    M

    S1.1

    EXISTING &NEWFOUNDATION &FLOOR PLANAREA A

    Project: 16745.00

    DFW

    SPK

    RO

    CK

    ING

    HA

    M C

    O. P

    UB

    LIC

    SC

    HO

    OLS

    JO

    HN

    WA

    YL

    AN

    D E

    S

    BID

    SE

    TB

    ID S

    ET

    BID SET

    02(01(2017

    SCALE: 1/8" = 1'(0"

    LEVEL 1 ( FOUNDATION & FLOOR PLAN AREA A

    NOTES:

    1) FIRST FLOOR SHALL BE 5" SLAB ON GRADE REINFORCED w/ 6x6(W2.1xW2.1 OVER 15 MIL POLYETHYLENE VAPOR BARRIER AND MINIMUM 4" OF WASHED GRAVEL.2) TOP OF SLAB SHALL BE AT ELEVATION 1296.98' (+0'(0") UNLESS OTHERWISE NOTED ON PLAN.3) TOP OF FOOTING ELEVATIONS ARE SHOWN THUS (000.00) ON PLAN.4) DROP FOOTING ELEVATIONS AS REQUIRED TO OBTAIN DESIGN SOIL BEARING OR TO CLEAR UNDERGROUND PIPING. SEE PLUMBING DRAWINGS FOR INVERT ELEVATIONS.5) SEE SITE PLAN FOR ALL EXTERIOR WORK SUCH AS SIDEWALKS, PAVING, CURBS AND GUTTERS, ETC.6) CJ INDICATES SLAB CONTROL JOINT. SEE TYPICAL DETAIL ON SHEET S?.?.7) GENERAL CONTRACTOR TO COORDINATE ALL DIMENSIONS AND ELEVATIONS WITH THE ARCHITECTURAL DRAWINGS AND RESOLVE ALL DISCREPANCIES WITH THE ARCHITECT PRIOR TO PLACEMENT OF CONCRETE.

    KEY PLAN

    A

    B

    C1 C2

    COLUMN SCHEDULE

    MARK SIZE BASE PLATE ANCHOR RODS REMARKS

    C1 HSS4x4x1/4 3/4x12x1'(0" (4) 3/4"Ø

    C2 Pipe3(1/2STD 1/2x12x1'(0" (4) 5/8"Ø

    COLUMN FOOTING SCHEDULE (1500 psf SOIL BRG. PRESSURE)

    MARK

    DIMENSIONS REINFORCINGLENGTH WIDTH THICKNESS

    F40 4'(0" 4'(0" 1'(0" (5) #4 EWB

    F46 4'(6" 4'(6" 1'(0" (5) #4 EWB

    F50 5'(0" 5'(0" 1'(2" (4) #5 EWB

    Revisions

  • LINE OF TEMPORARYSHORING UP TOEXISTING ROOF JOISTS

    F46

    C1

    ( (1.00' )

    C1

    F46 ( (1.00' )

    8'(0" 22'(8 3/4" 5'(4"

    INFILL EXISTING TRENCHDRAINS w/ MIN 4" CONCRETERE: ARCH DWGS

    10

    S2.1TYP

    Drawn:

    Checked:

    Scale:

    Constr

    uction D

    ocum

    ents

    for:

    1902 campus commons drivesuite 101

    reston, virginia 20191Tel: 703.476.3900Fax: 703.264.0733www.archinc.com

    Issued

    All

    repro

    duction +

    inte

    llectu

    al pro

    pert

    y r

    ights

    reserv

    ed b

    y A

    rchitectu

    re Incorp

    ora

    ted ©

    2016

    RE

    NO

    VA

    TIO

    N A

    ND

    AD

    DIT

    ION

    AS NOTED

    3930 Pender Drive, Suite175Fairfax, VA 22030(703) 890(5000email: [email protected] No 16745.00

    801 N

    . M

    AIN

    ST

    RE

    ET

    ,B

    RID

    GE

    WA

    TE

    R, V

    A 2

    2181

    T:\

    2016 D

    raw

    ings\D

    esig

    n P

    roje

    cts

    ( S

    K &

    DW

    \16745.0

    0 J

    ohn W

    ayla

    nd E

    S\1

    6745_John W

    ayla

    nd E

    S S

    tructu

    ral M

    odel (R

    evit 1

    6).

    rvt

    1/3

    1/2

    017 9

    :16:0

    3 A

    M

    S1.2

    EXISTINGFOUNDATION &FLOOR PLANAREA B

    Project: 16745.00

    Author

    Checker

    RO

    CK

    ING

    HA

    M C

    O. P

    UB

    LIC

    SC

    HO

    OLS

    JO

    HN

    WA

    YL

    AN

    D E

    S

    BID

    SE

    TB

    ID S

    ET

    BID SET

    02(01(2017

    SCALE: 1/8" = 1'(0"

    LEVEL 1 ( FOUNDATION & FLOOR PLAN AREA BKEY PLAN

    A

    B

    C1 C2

    Revisions

  • 8W

    F17 (

    E)

    8WF17 (E)

    20K

    6

    16J5 (

    E)

    16J6 (

    E)

    16J5 (E)

    16J4 (

    E)

    16J4 (

    E)

    16J5 (E)

    10J3 (

    E)

    22J8 (

    E)

    8J2

    (E

    )

    16J4 (

    E)

    10WF25 (E) 8WF17 (E) 10WF25 (E)

    16J4 (E)

    8J2 (E)

    LINE OF TEMPORARYSHORING FOR EXISTINGROOF JOISTS

    W10x33

    W10x33

    8J2

    (E

    )

    16J6 (

    E)

    14H

    5 (

    E)

    TO BE REMOVED TO BE REMOVED

    W21x68 (NEW)

    EXISTING 3 1/2" DIAMETERPIPE COLUMN TO REMAIN

    EXISTING COLUMN TO BEREMOVED AFTER ROOFIS SHORED

    LINE OF TEMPORARYSHORING FOR EXISTINGROOF JOISTS

    EXISTING BEARING WALLTO BE REMOVED AFTERROOF JOISTS ARE SHORED

    EXISTING BEARING WALLTO BE REMOVED AFTERROOF JOISTS ARE SHORED

    NEW COLUMN

    NEW COLUMN

    RAH(515000 lbs MAX

    RAH(CAF7500 lbs MAX

    RAH(415000 lbs MAX

    RAH(KIT5000 lbs MAX

    (2)

    20

    K6

    (2)

    20

    K6

    20K

    6

    20K

    6

    8J2

    (E

    )

    8J2

    (E

    )

    8J2

    (E

    )

    8J2

    (E

    )

    8J2

    (E

    )

    8J2

    (E

    )

    8J2

    (E

    )

    8J2

    (E

    )

    8J2

    (E

    )

    8J2

    (E

    )

    8J2

    (E

    )

    EXISTING 10J3 JOISTS& MEZZANINE SLAB BELOWTO BE REMOVED

    6B

    8.5

    (E

    )

    10J2 (E)

    8W

    F17 (

    E)

    10J2 (E) 10J2 (E)

    8W

    F17 (

    E)

    8J2 (E)

    8B10 (E)

    8B10 (E)

    JR1

    JR1

    JR1

    JR1

    JR1

    JR1

    JR1

    JR1

    JR1

    JR1

    C6x8.2

    C6x8.2

    C6x8.2

    C6x8.2

    C6x8.2

    C6x8.2

    NEW (6) C6 TO BEARON EXISTING WALL w/PL 4x5/16x0'(6" ATEACH END (TYP)

    ANGLE FRAME PERTYP DETAIL ON S3.2

    ANGLE FRAME PERTYP DETAIL ON S3.2

    ANGLE FRAME PERTYP DETAIL ON S3.2

    ANGLE FRAME PERTYP DETAIL ON S3.2

    1

    S3.1

    2

    S3.1

    3

    S3.1

    5

    S3.1

    6

    S3.1

    7

    S3.1

    8

    S3.1

    9

    S3.1

    C2

    BOT OF EXISTING DECKEL +11'(1 1/8" (VIF)

    GROUT EXISTINGWALL SOLID(8"x24" MINIMUM)

    NEW BRG PL 3/8x10x6w/ (2) 12" DIA x 4" LONGHEADED STUDS

    NEW BRG PL 3/8x10x6w/ (2) 12" DIA x 4" LONGHEADED STUDS

    NEW BRG PL 3/8x10x6w/ (2) 12" DIA x 4" LONGHEADED STUDS

    (2)

    20

    K6

    (2)

    20

    K6

    MAU(11500 lbs MAX

    ANGLE FRAME PERTYP DETAIL ON S3.2

    JR5

    JR5

    JR5

    JR5

    JR

    4

    JR

    4

    JR

    4

    JR

    4

    JR

    4

    JR

    4

    NOTE: ONLY REINFORCEINSIDE FACE (USE HALF OFSCHEDULED REINFORCING

    KITCHEN HOODRE: ARCH/MECH DWGS

    JR1

    24J8 (E)24J8 (E)

    JR1

    W8x15w/ BOTT PL 5/16x11" (VIF)

    W8x15

    w/ B

    OT

    T P

    L 5

    /16x11

    " (V

    IF)

    Drawn:

    Checked:

    Scale:

    Constr

    uction D

    ocum

    ents

    for:

    1902 campus commons drivesuite 101

    reston, virginia 20191Tel: 703.476.3900Fax: 703.264.0733www.archinc.com

    Issued

    All

    repro

    duction +

    inte

    llectu

    al pro

    pert

    y r

    ights

    reserv

    ed b

    y A

    rchitectu

    re Incorp

    ora

    ted ©

    2016

    RE

    NO

    VA

    TIO

    N A

    ND

    AD

    DIT

    ION

    AS NOTED

    3930 Pender Drive, Suite175Fairfax, VA 22030(703) 890(5000email: [email protected] No 16745.00

    801 N

    . M

    AIN

    ST

    RE

    ET

    ,B

    RID

    GE

    WA

    TE

    R, V

    A 2

    2181

    T:\

    2016 D

    raw

    ings\D

    esig

    n P

    roje

    cts

    ( S

    K &

    DW

    \16745.0

    0 J

    ohn W

    ayla

    nd E

    S\1

    6745_John W

    ayla

    nd E

    S S

    tructu

    ral M

    odel (R

    evit 1

    6).

    rvt

    1/3

    1/2

    017 9

    :16:0

    6 A

    M

    S1.3

    ROOF FRAMINGPLAN AREA A

    Project: 16745.00

    DFW

    SPK

    RO

    CK

    ING

    HA

    M C

    O. P

    UB

    LIC

    SC

    HO

    OLS

    JO

    HN

    WA

    YL

    AN

    D E

    S

    BID

    SE

    TB

    ID S

    ET

    BID SET

    02(01(2017

    SCALE: 1/8" = 1'(0"

    ROOF FRAMING PLAN ( AREA A

    NOTES:

    1) SEE PLAN FOR JOIST BEARING ELEVATIONS.2) ROOF DECK TO BE 1 1/2"(22 GAGE WIDE RIB (TYPE B) PAINTED.3) SEE ARCHITECTURAL DRAWINGS FOR ALL ROOF SLOPES AND DRAINS.4) SEE ARCHITECTURAL/MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF ALL OPENINGS. PROVIDE FRAMING AROUND OPENINGS PER TYPICAL DETAIL ON S3.0 UNLESS OTHERWISE NOTED.5) ML ( INDICATES MASONRY LINTEL. SEE SCHEDULE AND DETAIL ON SHEET S0.2.6) PROVIDE STANDARD SJI BRIDGING UNLESS OTHERWISE NOTED IN SECTIONS. PROVIDE (1) ROW OF BRIDGING AT FIRST PANEL POINT (TYP). DESIGN FOR A NET UPLIFT OF 10PSF.

    KEY PLAN

    A

    B

    C1 C2

    MATCH LINE ( SEE SHEET S1.3

    Revisions

  • 8W

    F17 (

    E)

    8WF17 (E)

    10J3 (

    E)

    16J6 (

    E)

    16J5 (E)

    16J6 (

    E)

    16J5 (

    E)

    16J4 (

    E)

    8J2 (E)

    32LA10 (E)

    16J6 (

    E)

    14J3 (

    E)

    18H

    5 (

    E)

    24H

    7 (

    E)

    14H

    5 (

    E)

    8H3 (E)

    16J4 (E)

    LINE OF TEMPORARYSHORING FOR EXISTINGROOF JOISTS

    RAH(217000 lbs MAX

    RAH(317000 lbs MAX

    RAH(GYM12000 lbs MAX

    EXISTING 10J3 JOISTS& MEZZANINE SLAB BELOWTO BE REMOVED

    10J2 (E) 10J2 (E)

    8J2

    (E

    )

    8J2

    (E

    )

    6B

    8.5

    (E

    )

    10J2 (E)

    8W

    F17 (

    E)

    10J2 (E) 10J2 (E)

    8W

    F17 (

    E)

    8B

    10 (

    E)

    8B

    10 (

    E)

    8B

    10 (

    E)

    8B10 (E)

    8H

    3 (

    E)

    JR2

    JR2

    JR2

    JR2

    JR2

    ANGLE FRAME PERTYP DETAIL ON S3.2

    ANGLE FRAME PERTYP DETAIL ON S3.2

    ANGLE FRAME PERTYP DETAIL ON S3.1

    4

    S3.1

    1'(0" CANT 1'(0" CANT

    W10x33 W16x45 W10x33

    BOT OF EXISTING DECKEL +11'(1 1/8" (VIF)

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    16J5 (

    E)

    W8x24

    TOP OF BEAM ATJOIST BEARING (VIF)

    BOT OF EXISTING DECKEL = +11'(1 1/8"

    JR2

    Drawn:

    Checked:

    Scale:

    Constr

    uction D

    ocum

    ents

    for:

    1902 campus commons drivesuite 101

    reston, virginia 20191Tel: 703.476.3900Fax: 703.264.0733www.archinc.com

    Issued

    All

    repro

    duction +

    inte

    llectu

    al pro

    pert

    y r

    ights

    reserv

    ed b

    y A

    rchitectu

    re Incorp

    ora

    ted ©

    2016

    RE

    NO

    VA

    TIO

    N A

    ND

    AD

    DIT

    ION

    AS NOTED

    3930 Pender Drive, Suite175Fairfax, VA 22030(703) 890(5000email: [email protected] No 16745.00

    801 N

    . M

    AIN

    ST

    RE

    ET

    ,B

    RID

    GE

    WA

    TE

    R, V

    A 2

    2181

    T:\

    2016 D

    raw

    ings\D

    esig

    n P

    roje

    cts

    ( S

    K &

    DW

    \16745.0

    0 J

    ohn W

    ayla

    nd E

    S\1

    6745_John W

    ayla

    nd E

    S S

    tructu

    ral M

    odel (R

    evit 1

    6).

    rvt

    1/3

    1/2

    017 9

    :16:0

    9 A

    M

    S1.4

    ROOF FRAMINGPLAN AREA B

    Project: 16745.00

    DFW

    SPK

    RO

    CK

    ING

    HA

    M C

    O. P

    UB

    LIC

    SC

    HO

    OLS

    JO

    HN

    WA

    YL

    AN

    D E

    S

    BID

    SE

    TB

    ID S

    ET

    BID SET

    02(01(2017

    SCALE: 1/8" = 1'(0"

    ROOF FRAMING PLAN ( AREA B

    KEY PLAN

    A

    B

    C1 C2

    MATCH LINE ( SEE SHEET S1.4

    MATCH LINE ( SEE SHEET S1.2

    Revisions

  • 16J5 (

    E)

    16J6 (

    E)

    24J8 (

    E)

    24H9 (E)

    14J6 (E)

    8J2 (E)14J6 (E)

    18H5 (E)

    8H3 (E)

    18H5 (E)

    14WF30 (E)

    14WF30 (E)

    8B15 (E)

    RAH(115000 lbs MAX

    RAH(217000 lbs MAX

    RAH(317000 lbs MAX

    10J2 (E) 10J2 (E)

    8J2

    (E

    )

    8J2

    (E

    )

    8B

    10 (

    E)

    8B

    10 (

    E)

    8B

    10 (

    E)

    8B10 (E)

    8H

    3 (

    E)

    ANGLE FRAME PERTYP DETAIL ON S3.2

    ANGLE FRAME PERTYP DETAIL ON S3.1

    C6x8.2

    C6x8.2

    C6x8.2

    C6x8.2

    C6x8.2

    C6x8.2

    C6x8.2

    C6x8.2

    NEW (8) C6 TO BEARON EXISTING WALL w/PL 4x5/16x0'(6" ATEACH END (TYP)

    ANGLE FRAME PERTYP DETAIL ON S3.2

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    NEW (9) C8 TO BEARON EXISTING WALL w/PL 4x5/16x0'(6" ATEACH END (TYP)

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    16J5 (

    E)

    8B10 (E)6B8.5 (E)

    W8x24

    W8x24

    w/ TOP PL 11x5/16TOP PL AT JOIST BEARING

    TOP OF BEAM ATJOIST BEARING (VIF)

    LINE OF TEMPORARYSHORING FOR EXISTINGROOF JOISTS

    LINES OF TEMPORARYSHORING FOR EXISTINGROOF JOISTS

    BOT OF EXISTING DECKEL = +11'(1 1/8"

    BOT OF EXISTING DECKEL = +11'(1 1/8"

    (

    (((

    16J6 (

    E)

    16J5 (

    E)

    16J5 (

    E)

    16J5 (

    E)

    RAH(317000 lbs MAX

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    C8x1

    1.5

    Drawn:

    Checked:

    Scale:

    Constr

    uction D

    ocum

    ents

    for:

    1902 campus commons drivesuite 101

    reston, virginia 20191Tel: 703.476.3900Fax: 703.264.0733www.archinc.com

    Issued

    All

    repro

    duction +

    inte

    llectu

    al pro

    pert

    y r

    ights

    reserv

    ed b

    y A

    rchitectu

    re Incorp

    ora

    ted ©

    2016

    RE

    NO

    VA

    TIO

    N A

    ND

    AD

    DIT

    ION

    AS NOTED

    3930 Pender Drive, Suite175Fairfax, VA 22030(703) 890(5000email: [email protected] No 16745.00

    801 N

    . M

    AIN

    ST

    RE

    ET

    ,B

    RID

    GE

    WA

    TE

    R, V

    A 2

    2181

    T:\

    2016 D

    raw

    ings\D

    esig

    n P

    roje

    cts

    ( S

    K &

    DW

    \16745.0

    0 J

    ohn W

    ayla

    nd E

    S\1

    6745_John W

    ayla

    nd E

    S S

    tructu

    ral M

    odel (R

    evit 1

    6).

    rvt

    1/3

    1/2

    017 9

    :16:1

    2 A

    M

    S1.5

    ROOF FRAMINGPLAN AREAS C1& C2

    Project: 16745.00

    DFW

    SPK

    RO

    CK

    ING

    HA

    M C

    O. P

    UB

    LIC

    SC

    HO

    OLS

    JO

    HN

    WA

    YL

    AN

    D E

    S

    BID

    SE

    TB

    ID S

    ET

    BID SET

    02(01(2017

    SCALE: 1/8" = 1'(0"

    ROOF FRAMING PLAN ( AREA C1

    SCALE: 1/8" = 1'(0"

    ROOF FRAMING PLAN ( AREA C2

    KEY PLAN

    A

    B

    C1 C2

    MATCH LINE ( SEE SHEET S1.3

    MA

    TC

    H L

    INE

    ( S

    EE

    AR

    EA

    C1 (

    TH

    IS S

    HE

    ET

    MA

    TC

    H L

    INE

    ( S

    EE

    AR

    EA

    C2 (

    TH

    IS S

    HE

    ET

    Revisions

  • LEVEL 10"

    4 1

    /2"

    FOOTING SIZE& REINFORCINGRE: PLAN & SCHEDULE

    FINISH GRADERE: CIVIL DWGS

    ASPHALTSLIP SHEET

    8" CMUw/ #4 @ 16" o/c

    2'(6

    " (M

    IN)

    LEVEL 10"

    FOOTING SIZE& REINFORCINGRE: PLAN & SCHEDULE

    FINISH GRADERE: CIVIL DWGS

    ASPHALTSLIP SHEET

    8" CMUw/ #4 @ 16" o/c

    2'(6

    " (M

    IN)

    LEVEL 10"

    ASPHALTSLIP SHEET

    EXISTINGSLAB

    EXISTINGWALL

    EXISTINGFOOTING

    MIN

    1'(4"

    VIF

    1'(0"

    MIN8"

    #4 @ 24" x 1'!7" LONGDRILL & EPOXY GROUT6" INTO EXISTING FOOTING

    (2) #4 CONT

    (3) #4 CONT

    #4 @ 24" o/c

    1" GAP 7 5/8"

    8" CMURE: PLAN FORREINFORCING

    LEVEL 10"

    EXISTINGSLAB

    EXISTINGWALL

    EXISTINGFOOTING V

    IF

    1'(0"

    MIN8"

    #4 @ 24" x 1'!3" LONGDRILL & EPOXY GROUT6" INTO EXISTING FOOTING

    (2) #4 CONT

    (3) #4 CONT

    #4 @ 24" o/c

    MIN

    1'(0"

    4 1

    /2"

    11 1

    /2"

    #4 @ 12" o/c

    2'(0"

    8" CMUw/ #4 @ 16" o/c

    6" 8" 1'(8"

    2'(10"

    (4) #4 CONT #4 @ 24" o/c

    #5 @ 12" o/cVERT

    #4 @ 12" o/cHORIZ

    SIDEWALK/FINISH GRADERE: CIVIL DWGS

    LOADING DOCK SLABRE: CIVIL DWGS

    DOWELS TO MATCHVERT REINFORCING

    1'(0"

    2'(0

    " M

    AX

    1'(6

    " M

    IN

    LEVEL 10"

    2'(10"

    #5 @ 12" o/cVERT

    #4 @ 12" o/cHORIZ

    LOADING DOCKSLAB

    LOADING DOCK SLABRE: CIVIL DWGS

    #4 @ 12" o/c

    2'(0"

    (1) #4 CONT

    6" 8" 1'(8"

    EXISTING SLABON GRADE

    EXISTINGFOOTING

    EXISTINGWALL

    (4) #4 CONT #4 @ 24" o/c

    RE

    : C

    IVIL

    DW

    GS

    VA

    RIE

    S 2

    '(0

    " M

    AX

    1'(6

    " M

    IN1

    '(0"

    LEVEL 10"

    #3 @ 12" x 1'!4" LONGDRILL & EPOXY GROUT4" INTO EXISTING SLAB(2 SIDES)

    STRUCTURALSTYROFOAMFILL ENTIRE PITRE: PLAN

    EXISTINGFOOTINGEXISTING

    PIT SLABON GRADE

    EXISTINGFOOTING

    EXISTINGWALL

    EXISTINGWALL

    EXISTING SLABON GRADE

    LEVEL 10"

    #4 @ 12" x 3'!4" LONGDRILL & EPOXY GROUT4" INTO EXISTING SLAB(3 DOWELS MINIMUM)

    EXISTINGSLAB

    EXISTINGWALL

    EXISTINGFOOTING V

    IF

    1'(0"

    MIN8"

    #4 @ 24" x 1'!3" LONGDRILL & EPOXY GROUT6" INTO EXISTING FOOTING

    (2) #4 CONT

    (3) #4 CONT

    #4 @ 24" o/c

    MIN

    1'(0"

    8"

    8" CMUw/ #4 @ 16" o/c

    LEVEL 10"

    #3 @ 12" x 1'!4" LONGDRILL & EPOXY GROUT4" INTO EXISTING SLAB(2 SIDES)

    EXISTING SLABON GRADE

    LEVEL 10"

    EXISTINGSLAB

    #3 @ 18" x 1'!4" LONGDRILL & EPOXY GROUT4" INTO EXISTING SLAB

    REMOVE EXISTINGFOOTING AT NEWCOLUMN FOOTING

    FOOTING SIZE& REINFORCINGRE: PLAN & SCHEDULE

    REMOVE EXISTINGCMU WALL AFTERSHORING

    COLUMN SIZE& BASE PLATERE: PLAN & SCHEDULE

    SAW CUTEXISTING SLAB

    LEVEL 10"

    FOOTING SIZE& REINFORCINGRE: PLAN & SCHEDULE

    EXISTINGSLAB

    #3 @ 18" x 1'!4" LONGDRILL & EPOXY GROUT4" INTO EXISTING SLAB

    NEW MASONRY PIERRE: PLAN

    SAW CUTEXISTING SLAB

    Drawn:

    Checked:

    Scale:

    Constr

    uction D

    ocum

    ents

    for:

    1902 campus commons drivesuite 101

    reston, virginia 20191Tel: 703.476.3900Fax: 703.264.0733www.archinc.com

    Issued

    All

    repro

    duction +

    inte

    llectu

    al pro

    pert

    y r

    ights

    reserv

    ed b

    y A

    rchitectu

    re Incorp

    ora

    ted ©

    2016

    RE

    NO

    VA

    TIO

    N A

    ND

    AD

    DIT

    ION

    AS NOTED

    3930 Pender Drive, Suite175Fairfax, VA 22030(703) 890(5000email: [email protected] No 16745.00

    801 N

    . M

    AIN

    ST

    RE

    ET

    ,B

    RID

    GE

    WA

    TE

    R, V

    A 2

    2181

    T:\

    2016 D

    raw

    ings\D

    esig

    n P

    roje

    cts

    ( S

    K &

    DW

    \16745.0

    0 J

    ohn W

    ayla

    nd E

    S\1

    6745_John W

    ayla

    nd E

    S S

    tructu

    ral M

    odel (R

    evit 1

    6).

    rvt

    1/3

    1/2

    017 9

    :16:1

    5 A

    M

    S2.1

    FOUNDATIONSECTIONS &TYPICALDETAILS

    Project: 16745.00

    DFW

    SPK

    RO

    CK

    ING

    HA

    M C

    O. P

    UB

    LIC

    SC

    HO

    OLS

    JO

    HN

    WA

    YL

    AN

    D E

    S

    BID

    SE

    TB

    ID S

    ET

    BID SET

    02(01(2017

    Section 1/2" = 1'(0" S2.1

    1 Section 1/2" = 1'(0" S2.1

    2 Section 1/2" = 1'(0" S2.1

    3 Section 1/2" = 1'(0" S2.1

    4 Section 1/2" = 1'(0" S2.1

    5

    Section 1/2" = 1'(0" S2.1

    6 Section 1/2" = 1'(0" S2.1

    7 Section 1/2" = 1'(0" S2.1

    8 Section 3/4" = 1'(0" S2.1

    9

    Section 3/4" = 1'(0" S2.1

    10 Section 1/2" = 1'(0" S2.1

    11

    Revisions

  • 8"

    1'(

    0" T

    8"

    (MIN

    )

    1'!4"

    (MA

    X)

    1'(4" 1'(2"1'!4"

    2'!8"

    T

    8"

    (MIN

    )

    1'!4"

    (MA

    X)

    1'(

    0"

    8"

    T

    TYPICAL STEPPED FOOTING DETAIL TYPICAL SLAB ON GRADE DETAILS

    CONSTRUCTION JOINT CONTROL JOINT

    6"

    FINISH FLOOREL (SEE PLAN)

    TYPICAL DEPRESSED SLAB DETAIL

    1'(0"

    FINISH FLOOREL (SEE PLAN)

    6"

    1' (4"

    4"

    TYPICAL CONCRETE STAIR ON GRADE DETAIL

    2'(6"

    (MIN

    )

    3" CLR.

    8"

    MIN.

    4"

    1'(0"

    MIN.

    4"

    5"

    4'(0

    " M

    AX

    HE

    IGH

    T 11

    4"

    1' (0"

    6 1/ 2

    "

    1' (3 3

    /16"

    2 1/2"

    8" 5 7/8"

    4"

    3'(

    6 1

    /8"

    2'(

    11

    1/1

    6"

    TYPICAL HOUSEKEEPING PAD DETAIL

    6"

    6"

    NOTE: CONTROL JOINTS/CONSTRUCTIONJOINTS SHALL CREATE PANELS OF 225SQ. FEET (MAXIMUM), WITH PANELASPECT RATIOS NO GREATER THAN 1.5TO 1.

    3 1

    /4"

    2"

    (TY

    P.)

    TYPICAL TURNED DOWN SLAB DETAIL

    #4 @ 24"2'(6

    8"

    2'(6"

    (MIN

    )3

    '(0

    "

    5"

    8 5/16"

    FIN. FLR. EL. (SEE PLAN)

    SIZE & NUMBERTO MATCH FOOTINGREINFORCING

    SEE PLAN FORSLAB THICKNESS

    SAWCUT (GREATER OF 1" AND1/4 OF SLAB DEPTH) WITHIN12 HOURS OF POUR(DO NOT INTERRUPT MESHT)

    METAL KEY!FORM BY KEYFOLD, INCOR EQUAL (INTERRRUPT MESH ATJOINTOPTIONAL FOOTING

    CONFIGURATION

    #4 AT ALL CORNERSAND 2'!0" o/c MAXAT ALL EDGES

    CHAMFERCORNER

    SLAB ONGRADE

    #4 CONT

    6x6!W1.4xW1.4

    PRIME w/ EPOXYBONDING AGENT

    SLAB DEPRESSIONSEE PLAN (8" MAX)

    SEE PLAN FOR SLABTHICKNESS (TYP)

    FINISHED GRADESEE CIVIL DWGS

    #4 @ 12" CONT

    SEE PLAN FORSLAB THICKNESS

    NOTE: SEE ARCH DWGS FOR DIMENSIONS & RAILING INFORMATION

    SEE PLAN

    8" CONCRETE CHEEKWALL AT EXPOSED SIDEAS REQUIRED w/ #4 @12" EW

    #4 @12"

    #4 @ 12" EW

    #4 AT EACH RISERHOOK INTOCHEEK WALLS

    MINIMUM 4" OFCUSHED STONE

    FINISHEDGRADE

    2'!6"

    LAP

    (1) #3 NOSING BAR(TYPICAL)

    CONCRETE FOOTINGSEE PLAN/SCHEDULE

    CONC. FOUNDATIONWALL (TYP WALLREINFORCING NOTSHOWN FOR CLARITY)

    SEE TYPICAL WALLOPENING REINFORCINGDETAIL FOR MOREINFORMATION

    2" RIGID INSULATIONCOVER

    NOTE:DROP & STEP FOOTING ASREQUIRED FOR UTILITIES.COORDINATE w/ MEP FORALL CONDITIONS.

    TYPICAL DETAIL FOR UTILITIESRUNNING THRU FOUNDATION WALL

    (DETAIL ELEVATION)

    TYPICAL DETAIL FOR UTILITIESRUNNING BELOW FOOTINGS (DETAIL ELEVATION)

    CMU FOUNDATIONFOUNDATION WALL

    1

    11

    1

    MIN 2" RIGID INSULATIONALL AROUND

    (3) #4

    #4 SWBEACH SIDE

    (3) #4

    U.N

    .O.

    12

    " T

    HK

    . F

    TG

    .

    2'(0' MIN. AS REQ'D. 2'(0' MIN.

    3"

    MIN

    .

    Section

    TYPICAL DETAIL FOR UTILITIESRUNNING THRU FOUNDATION WALL

    DETAIL ELEVATION

    AAAA

    S�2.2S�2.2S�2.2S�2.2

    AAAA

    S�2.2S�2.2S�2.2S�2.2

    CMU FOUNDATIONWALL

    (1) 6x8 PRECASTCONCRETE LINTELw/ (1) #5 T&B (2) 4x8 PRECAST CONCRETE

    LINTEL w/ #5 T&B

    GRADE

    2" RIGIDINSULATION COVER

    SEE PLAN/SCHEDULEFOR FOOTING SIZEREINFORCING & ELEVATION

    CONCRETEFOOTING

    PRECAST CONCRETE LINTEL(8" MIN BRG EACH END)

    NOTE:DROP & STEP FOOTING ASREQUIRED FOR UTILITIES.COORDINATE w/ MPE FORALL CONDITIONS.

    NOTE:SEE TYPICALSTEPPED FOOTINGDETAIL IF REQUIRED

    TYPICAL DETAIL FOR UTILITIESADJACENT TO FOOTINGS

    1

    1

    UTILITYLINE

    PR

    OV

    IDE

    AS

    RE

    Q'D

    PE

    R P

    RO

    XIM

    ITY

    &E

    LE

    VA

    TIO

    N O

    FU

    TIL

    ITY

    FINISH GRADE

    SEE PLAN/SCHEDULE FORFOOTING SIZE, REINF. & EL.

    CMU FOUNDATION WALL(TYP.WALL REINFORCING &DOWELSNOT SHOWN FOR CLARITY)

    3'(

    0"

    2 3

    6

    1

    4 5

    107 8 9

    NEW 3000 PSI CONCRETEUNDERPINNING. USE HI(EARLYSTRENGTH CONCRETE ONLY

    3" DRYPACK WITH"EMBECO" MORTAROR EQUAL

    EXISTING BUILDINGWALL & FOOTING

    NOTES:

    1) UNDERPIN IN 4'!0" WIDESECTIONSSEE PLAN FOR PLACING ORDER.

    2) ALLOW 72 HOURS CURING TIMEBETWEEN DRYPACK OF ONESECTION AND EXCAVATION OFADJACENT SECTION.

    3) DRYPACK 24 HOURS AFTERPOURING UNDERPINNING

    NOTE:

    INFORMATION SHOWN IS FOR CONCEPT ONLY. ACTUAL DESIGN/DETAILINGOF UNDERPINNING IS TO BE PERFORMED BY A REGISTEREDPROFESSIONALENGINEER IN THE STATE IN WHICH THE CONSTRUCTION IS TO BEPERFORMED HIRED BY THE CONTRACTOR AT CONTRCTOR'S EXPENSE.SIGNED AND SEALED DRAWINGS AND CALCULATIONS SHALL BESUBMITTED FOR REVIEW AND APPROVAL PRIOR TO START OF WORK.SEE PLANS FOR APPROXIMATE LOCATION AND EXTENT OFUNDERPINNING.

    PLACING ORDEROFUNDERPINNING

    EXISTING BUILDINGWALL & FOOTINGTO BE UNDERPINNEDAT NEW PIPES

    NEW UNDERPINNINGINDICATED BY HATCH

    TYPICAL PLAN

    NEW CHILLER PIPES

    #3 @ 12" x 1'(4" DOWELSDRILL & EPOXY GROUT4" INTO EXISTING SLAB

    TYPICAL UNDERPINNING DETAIL11

    11111111

    S2.2S2.2S2.2S2.2

    3"

    2'(4

    " (V

    IF)

    RE

    : M

    EC

    H D

    WG

    S

    3'(0"

    1'(0

    " M

    IN

    4'(0" TYP

    2nd

    1st

    SAW CUT NEW TRENCH

    NEW PIPECOORDINATE w/PLUMBING DWGS

    REPLACE SLAB ON GRADETO MATCH EXISTING SLABw/ 6x6(W1.4xW1.4 (MIN)

    #3@16" x 1'(4" LONGDRILL & EPOXY GROUT4" INTO EXISTING SLAB

    TYPICAL SLAB TRENCH FOR NEW PIPING DETAIL12

    Drawn:

    Checked:

    Scale:

    Constr

    uction D

    ocum

    ents

    for:

    1902 campus commons drivesuite 101

    reston, virginia 20191Tel: 703.476.3900Fax: 703.264.0733www.archinc.com

    Issued

    All

    repro

    duction +

    inte

    llectu

    al pro

    pert

    y r

    ights

    reserv

    ed b

    y A

    rchitectu

    re Incorp

    ora

    ted ©

    2016

    RE

    NO

    VA

    TIO

    N A

    ND

    AD

    DIT

    ION

    AS NOTED

    3930 Pender Drive, Suite175Fairfax, VA 22030(703) 890(5000email: [email protected] No 16745.00

    801 N

    . M

    AIN

    ST

    RE

    ET

    ,B

    RID

    GE

    WA

    TE

    R, V

    A 2

    2181

    T:\

    2016 D

    raw

    ings\D

    esig

    n P

    roje

    cts

    ( S

    K &

    DW

    \16745.0

    0 J

    ohn W

    ayla

    nd E

    S\1

    6745_John W

    ayla

    nd E

    S S

    tructu

    ral M

    odel (R

    evit 1

    6).

    rvt

    1/3

    1/2

    017 9

    :16:1

    7 A

    M

    S2.2

    FOUNDATIONTYPICALDETAILS

    Project: 16745.00

    Author

    Checker

    RO

    CK

    ING

    HA

    M C

    O. P

    UB

    LIC

    SC

    HO

    OLS

    JO

    HN

    WA

    YL

    AN

    D E

    S

    BID

    SE

    TB

    ID S

    ET

    BID SET

    02(01(2017

    Revisions

  • TEMPORARILY SHOREEXISTING JOISTS

    EXISTING22" JOISTS

    EXISTING22" JOISTS

    TEMPORARILY SHOREEXISTING JOISTS

    NEW W21RE: PLAN

    EXISTINGW10 & W8 BEAMSTO BE REMOVEDAFTER SHORINGEXISTING JOISTS

    EXISTINGROOF DECK

    LOWER ROOF10'(10 5/8"

    SHOP MEZANINE8'(11 1/4"

    TEMPORARILY SHOREEXISTING JOISTS

    EXISTING22" JOISTS

    EXISTING22" JOISTS

    TEMPORARILY SHOREEXISTING JOISTS

    NEW W21RE: PLAN

    EXISTINGW8 BEAMTO BE REMOVEDAFTER SHORINGEXISTING JOISTS

    EXISTINGROOF DECK

    NEW PIPE 3 1/2RE: PLAN

    EXISTING SHOP MEZZANINETO BE REMOVEDRE: ARCH DWGS

    NEW PIERRE: PLAN

    LOWER ROOF10'(10 5/8"

    SHOP MEZANINE8'(11 1/4"

    NEW W21RE: PLAN

    EXISTINGW10 BEAMTO REMAIN

    EXISTINGROOF DECK

    NEW PIPE 3 1/2RE: PLAN

    EXISTING SHOP MEZZANINETO BE REMOVEDRE: ARCH DWGS

    NEW PIERRE: PLAN

    EXISTING PIERRE: PLAN

    EXISTINGPIPE COLUMNTO REMAIN

    EXISTING W8TO BE REMOVEDAFTER SHORINGEXISTING ROOF JOISTS

    NEW BASE PLATERE: SCHEDULE

    NEW 3/4" CAP PLATE

    CUT BACKEXISTING W10AS REQUIRED

    NEW PL 5/8x6x6

    3/16

    LOWER ROOF10'(10 5/8"

    TEMPORARILY SHOREEXISTING JOISTS

    EXISTING14" JOISTSNEW W18

    RE: PLANTEMPORARILY SHOREEXISTING JOISTS

    EXISTING16" JOISTS

    EXISTING WALLTO BE REMOVED

    LOWER ROOF10'(10 5/8"

    JOISTRE: PLANMIN (2) COURSES OF

    CONT SOLID MASONRYUNDER JOIST BEARING

    PL 6 x 3/8 x 0'!8" w/(2) 1/2" DIA x 0'!6"HEADED STUDSAT EACH JOIST

    CONT BENT PL10x3x1/4 (LLH)WELDED TO JOISTSWELD DECK TO PLATE

    LOWER ROOF10'(10 5/8"

    JOISTRE: PLAN

    L2x2x1/4 X!BRACINGAT LINES OFBRIDGING& IN!BETWEEN

    CONT L4x3x5/16 w/VERT SLOTTED HOLES& 1/2" DIA BOLTS @ 32" o/cGROUTED IN CMU

    STANDARDSJI BRIDIGNG

    1'(2" 4"

    1'(6"

    CANTILEVERDECK

    LOWER ROOF10'(10 5/8"

    JOISTRE: PLANMIN (2) COURSES OF

    CONT SOLID MASONRYUNDER JOIST BEARING

    PL 6 x 3/8 x 0'!8" w/(2) 1/2" DIA x 0'!6"HEADED STUDSAT EACH JOIST

    CONT L4x3 1/2x5/16 (LLV)WELDED TO JOISTSWELD DECK TO ANGLE

    EXISTING JOISTRE: PLAN

    EXISTING WALLRE: PLAN

    1" EXP JT 7 5/8"

    LOWER ROOF10'(10 5/8"

    JOISTRE: PLAN

    L2x2x1/4 X!BRACINGAT LINES OFBRIDGING& IN!BETWEEN

    STANDARDSJI BRIDIGNG

    EXISTING JOISTRE: PLAN

    EXISTING WALLRE: PLAN

    LOWER ROOF10'(10 5/8"

    TEMPORARILY SHOREEXISTING JOISTS

    EXISTING8" JOISTS

    NEW W10RE: PLAN

    TEMPORARILY SHOREEXISTING JOISTS

    EXISTING16" JOISTS

    EXISTING WALLTO BE REMOVED

    Drawn:

    Checked:

    Scale:

    Constr

    uction D

    ocum

    ents

    for:

    1902 campus commons drivesuite 101

    reston, virginia 20191Tel: 703.476.3900Fax: 703.264.0733www.archinc.com

    Issued

    All

    repro

    duction +

    inte

    llectu

    al pro

    pert

    y r

    ights

    reserv

    ed b

    y A

    rchitectu

    re Incorp

    ora

    ted ©

    2016

    RE

    NO

    VA

    TIO

    N A

    ND

    AD

    DIT

    ION

    AS NOTED

    3930 Pender Drive, Suite175Fairfax, VA 22030(703) 890(5000email: [email protected] No 16745.00

    801 N

    . M

    AIN

    ST

    RE

    ET

    ,B

    RID

    GE

    WA

    TE

    R, V

    A 2

    2181

    T:\

    2016 D

    raw

    ings\D

    esig

    n P

    roje

    cts

    ( S

    K &

    DW

    \16745.0

    0 J

    ohn W

    ayla

    nd E

    S\1

    6745_John W

    ayla

    nd E

    S S

    tructu

    ral M

    odel (R

    evit 1

    6).

    rvt

    1/3

    1/2

    017 9

    :16:2

    0 A

    M

    S3.1

    ROOFSECTIONS

    Project: 16745.00

    Author

    Checker

    RO

    CK

    ING

    HA

    M C

    O. P

    UB

    LIC

    SC

    HO

    OLS

    JO

    HN

    WA

    YL

    AN

    D E

    S

    BID

    SE

    TB

    ID S

    ET

    BID SET

    02(01(2017

    Section 3/4" = 1'(0" S3.1

    1

    Section 3/4" = 1'(0" S3.1

    2 Section 3/4" = 1'(0" S3.1

    3

    Section 3/4" = 1'(0" S3.1

    4 Section 3/4" = 1'(0" S3.1

    5 Section 3/4" = 1'(0" S3.1

    6 Section 3/4" = 1'(0" S3.1

    7

    Section 3/4" = 1'(0" S3.1

    8 Section 3/4" = 1'(0" S3.1

    9

    Revisions

  • NOTES:

    ONE RIB REMOVED (6" DIAMETER) ! NO REINFORCING OR 0.045" PLATE (MIN)

    8" DIAMETER !!!!!!!!!!!!!!!!!!!!!!!!!!!! 0.045" PLATE (MIN)

    8" TO 13" DIAMETER !!!!!!!!!!!!!!!!!!! 0.057" PLATE (MIN)

    OVER 13" !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! USE ANGLE FRAME PER TYPICAL DETAIL

    TYPICAL ROOF DECK REINFORCING AT SMALL OPENINGS

    DUCTWORK INTERFERRINGWITH JOIST BRIDGING

    INSTALL NEW L2x2x1/4"X!BRACING PRIOR TOREMOVING BRIDGING

    INSTALL NEWL2x2x1/4"X!BRACING PRIOR TOREMOVING BRIDGING

    REMOVE BRIDGINGAFTER X!BRACINGIS INSTALLED

    ROOF OR FLOOR DECK

    JOIST (TYP)

    TYPICAL X!BRACING REQUIREMENTS ATDUCT BRIDGING INTERFERENCE DETAIL

    TYPICAL JOIST REINFORCEMENT

    NOTES:

    NUMBER OF MEMBERS

    T,B,BS15'!0"

    LOCATIONMIN. LENGTHMARK

    JR1 1/4" DIA

    SIZEL (ft) (NOTE 1) (NOTE 4)

    CHORD REINFORCING (V50) WEB REINFORCING

    1) "T" TOP, "B" BOTTOM, "NS" 1 SIDE, "BS" 2 SIDES.2) CENTER REINFORCEMENT ON CENTER OF JOIST SPAN AND EXTEND 3" PAST PANEL POINT.3) ALL WELDS TO BE E70 LOW HYDROGEN.4) NUMBER AND LOCATION OF DIAGONAL MEMBERS.

    MEASURED IN FIELD

    ACTUAL BOTTOM BAR LENGTH TO BE

    L/2 L/2

    EXTEND BAR 3" PASTNEXT PANEL POINT(TOP & BOTTOM)TYPICAL

    WEB REINFORCINGEACH SIDE

    EXISTING JOIST

    NEW ANGLESBOTH SIDES

    CENTERLINE OF JOIST

    MEASURED IN FIELD

    ACTUAL TOP BAR LENGTH TO BE

    L/2 L/2

    TYP3" MIN

    1/8 2

    AT PANEL POINTSAND MIDSPACING &12" AT ENDS

    .

    1/8TYP .

    NUMBER OF WEB MEMBERS

    .

    .

    (4) L1 1/2 x 1 1/2 x 3/16AT EACH END

    EXISTING JOIST REINFORCING DETAIL & SCHEDULE

    T,B,BS24'!0"JR2 5/8" DIA(6) L1 1/4 x 1 1/4 x 3/16AT EACH END

    T,B,BS18'!0"JR3 1/2" DIA(5) L1 x 1 x 1/8AT EACH END

    T,B,BS28'!0"JR4 3/4" DIA

    T,B,BS20'!0"JR5 1/2" DIA

    (6) L1 1/2 x 1 1/2 x 3/16AT EACH END(9) L1 1/2 x 1 1/2 x 3/16AT EACH END

    TYPICAL JOIST REINFORCING DETAILAT CONCENTRATED LOAD

    TYPICAL ROOF OPENING & RTUCURB SUPPORT DETAIL

    3/8

    "

    2'(1 1/8"

    1/2

    "

    L1 1/2x11/2x3/16 (TYP)(MIN WEB REINFORCINGFOR JOIST)

    HANGER ANGLE FORMECHANICAL EQUIPMENTOR ACCESSORY

    CL OF SUPPORT

    ADDITIONAL X!BRIDGINGAT CENTERLINE OFEQUIPMENT SUPPORT(EACH SIDE OF JOIST)

    *

    NOTES:1) PROVIDE AT PERIMETER OF ALL ROOFTOP MECHANICAL UNITS AND ROOF OPENINGS LARGER THAN 12" SQUARE AS REQUIRED.2) FOR OPENINGS LARGER THAN 6" UP TO 12",PROVIDE 2'!0"x2'!0"x0.071" STEEL PL WELDED TO DECK, OR SCREWED w/ SHEET METALSCREWS @ 6" o/c. (PROVIDE L3x3x5/16 AT ROOF SUMPS)

    METAL DECK(TYPICAL)

    SEE TYPICALJOIST REINFORCINGDETAIL AT MECHANICALUNITS

    L6x4x5/16 (LLV)(TYP 4 SIDES)

    CLIP L 6x4x3/8x0'!6" (LLV)(4 REQUIRED)

    SEE MECH DWGS &ARCH ROOF PLANFOR OPENING SIZESAND LOCATIONS

    TYPICAL ROOF OPENING & RTUCURB SUPPORT DETAIL AT EXISTING ROOF

    2'(1 1/8"

    NOTES:1) PROVIDE AT PERIMETER OF ALL ROOFTOP MECHANICAL UNITS AND ROOF OPENINGS LARGER THAN 12" SQUARE AS REQUIRED.2) FOR OPENINGS LARGER THAN 6" UP TO 12",PROVIDE 2'!0"x2'!0"x0.071" STEEL PL WELDED TO DECK, OR SCREWED w/ SHEET METALSCREWS @ 6" o/c. (PROVIDE L3x3x5/16 AT ROOF SUMPS)

    METAL DECK(TYPICAL)

    SEE TYPICALJOIST REINFORCINGDETAIL AT MECHANICALUNITS

    L6x4x5/16 (LLV)(TYP 4 SIDES)

    CLIP L 4x4x5/16x0'!4"(LLV)(4 REQUIRED)

    SEE MECH DWGS &ARCH ROOF PLANFOR OPENING SIZESAND LOCATIONS

    TYPICAL JOIST REINFORCING DETAILAT CONCENTRATED LOAD (> 250 lbs)

    L1 1/2x11/2x3/16 (TYP)(MIN WEB REINFORCINGFOR JOIST)

    HANGER ANGLE FORMECHANICAL EQUIPMENTOR ACCESSORY

    CL OF SUPPORT

    ADDITIONAL X!BRIDGINGAT CENTERLINE OFEQUIPMENT SUPPORT(EACH SIDE OF JOIST)

    *

    TYPICAL ROOF OPENING & RTUCURB SUPPORT DETAIL AT EXISTING ROOF

    2'(1 1/8"

    NOTES:1) PROVIDE AT PERIMETER OF ALL ROOFTOP MECHANICAL UNITS AND ROOF OPENINGS LARGER THAN 12" SQUARE AS REQUIRED.2) FOR OPENINGS LARGER THAN 6" UP TO 12",PROVIDE 2'!0"x2'!0"x0.071" STEEL PL WELDED TO DECK, OR SCREWED w/ SHEET METALSCREWS @ 6" o/c. (PROVIDE L3x3x5/16 AT ROOF SUMPS)

    METAL DECK(TYPICAL)

    SEE TYPICALJOIST REINFORCINGDETAIL AT MECHANICALUNITS

    L6x4x5/16 (LLV)(TYP 4 SIDES)

    CLIP L 4x4x5/16x0'!4"(LLV)(4 REQUIRED)

    SEE MECH DWGS &ARCH ROOF PLANFOR OPENING SIZESAND LOCATIONS

    Drawn:

    Checked:

    Scale:

    Constr

    uction D

    ocum

    ents

    for:

    1902 campus commons drivesuite 101

    reston, virginia 20191Tel: 703.476.3900Fax: 703.264.0733www.archinc.com

    Issued

    All

    repro

    duction +

    inte

    llectu

    al pro

    pert

    y r

    ights

    reserv

    ed b

    y A

    rchitectu

    re Incorp

    ora

    ted ©

    2016

    RE

    NO

    VA

    TIO

    N A

    ND

    AD

    DIT

    ION

    AS NOTED

    3930 Pender Drive, Suite175Fairfax, VA 22030(703) 890(5000email: [email protected] No 16745.00

    801 N

    . M

    AIN

    ST

    RE

    ET

    ,B

    RID

    GE

    WA

    TE

    R, V

    A 2

    2181

    T:\

    2016 D

    raw

    ings\D

    esig

    n P

    roje

    cts

    ( S

    K &

    DW

    \16745.0

    0 J

    ohn W

    ayla

    nd E

    S\1

    6745_John W

    ayla

    nd E

    S S

    tructu

    ral M

    odel (R

    evit 1

    6).

    rvt

    1/3

    1/2

    017 9

    :16:2

    1 A

    M

    S3.2

    ROOF FRAMINGTYPICALDETAILS

    Project: 16745.00

    Author

    Checker

    RO

    CK

    ING

    HA

    M C

    O. P

    UB

    LIC

    SC

    HO

    OLS

    JO

    HN

    WA

    YL

    AN

    D E

    S

    BID

    SE

    TB

    ID S

    ET

    BID SET

    02(01(2017

    Revisions

    SheetsS0.1 - STRUCTURAL NOTESS0.2 - DESIGN TABLESS1.1 - EXISTING & NEW FOUNDATION & FLOOR PLAN AREA AS1.2 - EXISTING FOUNDATION & FLOOR PLAN AREA BS1.3 - ROOF FRAMING PLAN AREA AS1.4 - ROOF FRAMING PLAN AREA BS1.5 - ROOF FRAMING PLAN AREAS C1 & C2S2.1 - FOUNDATION SECTIONS & TYPICAL DETAILSS2.2 - FOUNDATION TYPICAL DETAILSS3.1 - ROOF SECTIONSS3.2 - ROOF FRAMING TYPICAL DETAILS