2 3 4 Press [programming setting] for 3 seconds, enter into setting status, LED light on. Choose remote control channel, press [chan- nel setting] button, LED flash quickly. Programming setting ◆Method two:Change direction by programming button Press programming button, setting done, LED light off. Attention: Repeat this operation for max 16 channel remote control channel setting. Direction change ◆Delete limit and remote control channel Press programming button for 3 seconds, en- ter into setting status, LED light on. Press programming button for 7 seconds, delete all setted channel to EXW mode. LED light off. Short time press twice+ long time press [programming button] twice: short time press ( light flash) + short time press(light flash) + long time press for 3 seconds ( led light on) + long time press for 3 seconds ( led light off, motor indicate by vibration ) direction change done ① ② ① ② ◆Method one: Press [programming] button for 3 seconds, e- nter into setting status, LED light on. Press [ ] + [stop] button, LED light flash quickly. Channel Choose Left Press [programming button], direction change done, LED light off. ③ ① ② YR2118B transmitter function Remote control setting Basic remote control setting Before using transmitter, user must set “ remote control channel”, save the transmit cha- nnel in motor. If you need to set all previous remote channel invalid, please do “delete remote control” setting Transmitter’s open and close function is corresponding with curtain’s open and close dir- ection. If it’s opposite operation, please do “ direction change” setting. 1.Max 16 channels can be recorded in each motor. The motor will response to setted r- emote channel when receive signal. 2.When two motor are used in one track, set same channel for those two motors and re- mote control them on that channel. This setting doesn’t affect those two motor’s single co- ntrol function. 3.Each RAEX motor is compatible with Raex transmitter. YR2188B with more function, li- ke intermediate stop position function. So YR2188B is strongly recommened on installation and setting. 3V CR2032 ◆Remote control function Press transmitter [open] button, open the cur- tain, motor will move to the open position, st- op by locked -rotor or stop automatically after 3 minutes running. Press [close] button, close the curtain, motor move to the close limit position, stop by locked -rotor or stop automatically after 3 minutes ru- nning Press [stop] button during the process of open or close, motor stop immediately. ③ ① ② ◆Set 3 stop positions Press [channel setting]+ [intermediate stop 1 button] or [channel setting]+ [up tilting/ 75%] button, motor vibrate one time.Set the current position as stop position 1, stop position 1 will be 75% limit position. Press [channel setting] + [intermediate stop 3 button] or [channel setting] +[horizontal tilt- ing/ 50%],motor vibrate one time.Set the current position as stop position 3, stop pos- ition 3 will be 50% limit position. Press [channel setting] + [intermediate stop 2 button] or [channel setting] + [down tilting/ 25%] button, motor vibrate one time.Set the current position as stop position 2, stop position 2 will be 25% limit position. ① ② ③ ◆3 equal line stop position Press [intermediate stop position 1 button] or [up tilting/75%] button for 0.5 seconds at the motor stopped status, motor move to interme- diate stop position 1 and stop automatically. In- termediate stop 1 position is 75% of limit position. Press [intermediate stop 3 button] or [horizo- ntal tilting /50%] for 0.5 second, motor move to intermediate stop 3 position. Intermediate stop 3 position is 50% of limit position. Press [intermediate stop 2 button] or [down ti- lting/25%] for 0.5 second, motor move to inte- rmediate stop 2 position. Intermediate stop 2 position is 25% of limit position. ① ② ③ 0.5S 0.5S 0.5S ◆Resume limit position Press [channel setting] + [stop] button for 4 seconds, resume limit and intermediate stop position, LED flash one time, motor vibrate one time,and then resume limit done. 4S 4S Limit setting 1 .After power connection,first time to open or close the curtain, the motor will stop by locked -rotor at 0mm- 10mm to the close position. (if the track’s direction is wrong the automatic limit tolerance will be bigger after direction change, the tolerance resume normal level. ) 2.At stop status, power off and then connected , if no pulling curtain during power off, motor limit status no any change, the motor won’t crash to the end of track. If the pulling the cur- tain too big distance, after power connection , the motor may crash to the end of track and then resume limit. Power off during the motor’s moving process, the motor will resume li- mit after crash to end of track for the first time running. ◆Adjust the close limit position ( adjust the limit position after automatic limit ) Long press [channel setting] and [close] button for 4s,enter into close limit adjustment status, motor vibrate one time,LED light on. Within 30 seconds, repeat pressing [open], [stop] or [close] button, move to the position wanted. Press [channel setting button] for 4 seconds or press programming button, set the current position as close limit position, out of the st- atus of adjust close limit position, motor vibr- ate one time, LED light off. ① ② ③ 4S 4S 4S ◆Adjust open limit position (adjust the limit after automatic limit ) 5 Long press [channel setting] and open button for 4s,enter into open limit adjustment status, motor vibrate one time,LED light on. Within 30 seconds, repeat press [open], [stop] and [close] button, move to the posit- ion wanted. Press channel setting for 4 seconds or press programming button,set the current position as open limit position, out of the status of a- djust open limit position, motor vibrate one time,LED light off. ① ② ③ 4S 4S 4S + + + + + + 或 或 + + + 3S 3S 3S 3S 3S ◆Limit setting automatically 7S (back) (back) (back) (back) (back) (back) (back) (back) (back) Channel Choose Left Channel Channel Choose Right Up/Open Stop Down/Close Up tilt/75% Horizontal position/50% Down tilt/25% Channel setting ③