Top Banner
2 3 4 Press [programming setting] for 3 seconds, enter into setting status, LED light on. Choose remote control channel, press [chan- nel setting] button, LED flash quickly. Programming setting Method twoChange direction by programming button Press programming button, setting done, LED light off. Attention: Repeat this operation for max 16 channel remote control channel setting. Direction change Delete limit and remote control channel Press programming button for 3 seconds, en- ter into setting status, LED light on. Press programming button for 7 seconds, delete all setted channel to EXW mode. LED light off. Short time press twice+ long time press [programming button] twice: short time press ( light flash) + short time press(light flash) + long time press for 3 seconds ( led light on) + long time press for 3 seconds ( led light off, motor indicate by vibration ) direction change done Method onePress [programming] button for 3 seconds, e- nter into setting status, LED light on. Press [ ] + [stop] button, LED light flash quickly. Channel Choose Left Press [programming button], direction change done, LED light off. YR2118B transmitter function Remote control setting Basic remote control setting Before using transmitter, user must set “ remote control channel”, save the transmit cha- nnel in motor. If you need to set all previous remote channel invalid, please do “delete remote control” setting Transmitter’s open and close function is corresponding with curtain’s open and close dir- ection. If it’s opposite operation, please do “ direction change” setting. 1.Max 16 channels can be recorded in each motor. The motor will response to setted r- emote channel when receive signal. 2.When two motor are used in one track, set same channel for those two motors and re- mote control them on that channel. This setting doesn’t affect those two motor’s single co- ntrol function. 3.Each RAEX motor is compatible with Raex transmitter. YR2188B with more function, li- ke intermediate stop position function. So YR2188B is strongly recommened on installation and setting. 3V CR2032 Remote control function Press transmitter [open] button, open the cur- tain, motor will move to the open position, st- op by locked -rotor or stop automatically after 3 minutes running. Press [close] button, close the curtain, motor move to the close limit position, stop by locked -rotor or stop automatically after 3 minutes ru- nning Press [stop] button during the process of open or close, motor stop immediately. Set 3 stop positions Press [channel setting]+ [intermediate stop 1 button] or [channel setting]+ [up tilting/ 75%] button, motor vibrate one time.Set the current position as stop position 1, stop position 1 will be 75% limit position. Press [channel setting] + [intermediate stop 3 button] or [channel setting] +[horizontal tilt- ing/ 50%],motor vibrate one time.Set the current position as stop position 3, stop pos- ition 3 will be 50% limit position. Press [channel setting] + [intermediate stop 2 button] or [channel setting] + [down tilting/ 25%] button, motor vibrate one time.Set the current position as stop position 2, stop position 2 will be 25% limit position. 3 equal line stop position Press [intermediate stop position 1 button] or [up tilting/75%] button for 0.5 seconds at the motor stopped status, motor move to interme- diate stop position 1 and stop automatically. In- termediate stop 1 position is 75% of limit position. Press [intermediate stop 3 button] or [horizo- ntal tilting /50%] for 0.5 second, motor move to intermediate stop 3 position. Intermediate stop 3 position is 50% of limit position. Press [intermediate stop 2 button] or [down ti- lting/25%] for 0.5 second, motor move to inte- rmediate stop 2 position. Intermediate stop 2 position is 25% of limit position. 0.5S 0.5S 0.5S Resume limit position Press [channel setting] + [stop] button for 4 seconds, resume limit and intermediate stop position, LED flash one time, motor vibrate one time,and then resume limit done. 4S 4S Limit setting 1 .After power connection,first time to open or close the curtain, the motor will stop by locked -rotor at 0mm- 10mm to the close position. (if the track’s direction is wrong the automatic limit tolerance will be bigger after direction change, the tolerance resume normal level. ) 2.At stop status, power off and then connected , if no pulling curtain during power off, motor limit status no any change, the motor won’t crash to the end of track. If the pulling the cur- tain too big distance, after power connection , the motor may crash to the end of track and then resume limit. Power off during the motor’s moving process, the motor will resume li- mit after crash to end of track for the first time running. Adjust the close limit position ( adjust the limit position after automatic limit ) Long press [channel setting] and [close] button for 4s,enter into close limit adjustment status, motor vibrate one time,LED light on. Within 30 seconds, repeat pressing [open], [stop] or [close] button, move to the position wanted. Press [channel setting button] for 4 seconds or press programming button, set the current position as close limit position, out of the st- atus of adjust close limit position, motor vibr- ate one time, LED light off. 4S 4S 4S Adjust open limit position (adjust the limit after automatic limit ) 5 Long press [channel setting] and open button for 4s,enter into open limit adjustment status, motor vibrate one time,LED light on. Within 30 seconds, repeat press [open], [stop] and [close] button, move to the posit- ion wanted. Press channel setting for 4 seconds or press programming button,set the current position as open limit position, out of the status of a- djust open limit position, motor vibrate one time,LED light off. 4S 4S 4S + + + + + + + + + 3S 3S 3S 3S 3S Limit setting automatically 7S (back) (back) (back) (back) (back) (back) (back) (back) (back) Channel Choose Left Channel Channel Choose Right Up/Open Stop Down/Close Up tilt/75% Horizontal position/50% Down tilt/25% Channel setting
2

Remote control setting Delete limit and remote control ...

Nov 22, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Remote control setting Delete limit and remote control ...

2 3 4

Press [programming setting] for 3 seconds,

enter into setting status, LED light on.

Choose remote control channel, press [chan-

nel setting] button, LED flash quickly.

Programming setting

◆Method two:Change direction by programming button

Press programming button, setting done,

LED light off.

Attention: Repeat this operation for max 16 channel remote control channel setting.

Direction change

◆Delete limit and remote control channel

Press programming button for 3 seconds, en-

ter into setting status, LED light on.

Press programming button for 7 seconds,

delete all setted channel to EXW mode.

LED light off.

Short time press twice+ long time press [programming button] twice: short time press ( light

flash) + short time press(light flash) + long time press for 3 seconds ( led light on) + long

time press for 3 seconds ( led light off, motor indicate by vibration ) direction change done

① ②

① ②

◆Method one:

Press [programming] button for 3 seconds, e-

nter into setting status, LED light on.

Press [ ] + [stop] button,

LED light flash quickly.

Channel Choose Left

Press [programming button], direction change

done, LED light off.

① ②

YR2118B transmitter function

Remote control setting

Basic remote control setting

Before using transmitter, user must set “ remote control channel”, save the transmit cha-

nnel in motor.

If you need to set all previous remote channel invalid, please do “delete remote control”

setting

Transmitter’s open and close function is corresponding with curtain’s open and close dir-

ection. If it’s opposite operation, please do “ direction change” setting.

1.Max 16 channels can be recorded in each motor. The motor will response to setted r-

emote channel when receive signal.

2.When two motor are used in one track, set same channel for those two motors and re-

mote control them on that channel. This setting doesn’t affect those two motor’s single co-

ntrol function.

3.Each RAEX motor is compatible with Raex transmitter. YR2188B with more function, li-

ke intermediate stop position function. So YR2188B is strongly recommened on installation

and setting.

3V CR2032

◆Remote control function

Press transmitter [open] button, open the cur-

tain, motor will move to the open position, st-

op by locked -rotor or stop automatically after

3 minutes running.

Press [close] button, close the curtain, motor

move to the close limit position, stop by locked

-rotor or stop automatically after 3 minutes ru-

nning

Press [stop] button during the process of open

or close, motor stop immediately.

① ②

◆Set 3 stop positions

Press [channel setting]+ [intermediate stop 1 button] or [channel setting]+ [up tilting/ 75%]

button, motor vibrate one time.Set the current

position as stop position 1, stop position 1 will

be 75% limit position.

Press [channel setting] + [intermediate stop

3 button] or [channel setting] +[horizontal tilt-

ing/ 50%],motor vibrate one time.Set the

current position as stop position 3, stop pos-

ition 3 will be 50% limit position.

Press [channel setting] + [intermediate stop 2

button] or [channel setting] + [down tilting/ 25%]

button, motor vibrate one time.Set the current

position as stop position 2, stop position 2 will

be 25% limit position.

① ②

◆3 equal line stop position

Press [intermediate stop position 1 button] or

[up tilting/75%] button for 0.5 seconds at the

motor stopped status, motor move to interme-

diate stop position 1 and stop automatically. In-

termediate stop 1 position is 75% of limit

position.

Press [intermediate stop 3 button] or [horizo-

ntal tilting /50%] for 0.5 second, motor move

to intermediate stop 3 position. Intermediate

stop 3 position is 50% of limit position.

Press [intermediate stop 2 button] or [down ti-

lting/25%] for 0.5 second, motor move to inte-

rmediate stop 2 position. Intermediate stop 2

position is 25% of limit position.

① ②

0.5S

0.5S

0.5S

◆Resume limit position

Press [channel setting] + [stop] button for 4

seconds, resume limit and intermediate stop

position, LED flash one time, motor vibrate one time,and then resume limit done.

4S4S

Limit setting

1 .After power connection,first time to open or close the curtain, the motor will stop by locked

-rotor at 0mm- 10mm to the close position. (if the track’s direction is wrong the automatic

limit tolerance will be bigger after direction change, the tolerance resume normal level. )

2.At stop status, power off and then connected , if no pulling curtain during power off, motor

limit status no any change, the motor won’t crash to the end of track. If the pulling the cur-

tain too big distance, after power connection , the motor may crash to the end of track and

then resume limit. Power off during the motor’s moving process, the motor will resume li-

mit after crash to end of track for the first time running.

◆Adjust the close limit position

( adjust the limit position after automatic limit )

Long press [channel setting] and [close] button for 4s,enter into close limit adjustment status,

motor vibrate one time,LED light on.

Within 30 seconds, repeat pressing [open],

[stop] or [close] button, move to the position

wanted.

Press [channel setting button] for 4 seconds

or press programming button, set the current

position as close limit position, out of the st-

atus of adjust close limit position, motor vibr-

ate one time, LED light off.

① ②

4S

4S

4S

◆Adjust open limit position

(adjust the limit after automatic limit )

5

Long press [channel setting] and open button for 4s,enter into open limit adjustment status,

motor vibrate one time,LED light on.

Within 30 seconds, repeat press [open],

[stop] and [close] button, move to the posit-

ion wanted.

Press channel setting for 4 seconds or press

programming button,set the current position

as open limit position, out of the status of a-

djust open limit position, motor vibrate one time,LED light off.

① ②

4S

4S

4S

+ +

+

+

+

+

+ + +3S

3S

3S

3S 3S

◆Limit setting automatically

7S

(back)

(back) (back)

(back)

(back)

(back)

(back)

(back)

(back)

Channel Choose Left

Channel

Channel Choose Right

Up/Open

Stop

Down/Close

Up tilt/75%

Horizontal position/50%

Down tilt/25%

Channel setting

Page 2: Remote control setting Delete limit and remote control ...

6 7 8

Press [stop] + [open] button for 4 seconds u-

ntil LED light on, motor vibrate shortly. Within

3 seconds, press channel setting of the tran-

smitter’s back , motor vibrate shortly, operati-

on done, switch on this function.

Press [stop]+ [close] button for 4 seconds un-

til LED light on, motor vibrate shortly. Within 3

seconds, press channel setting on the trans-

mitter’s back , motor vibrate shortly, operation

done, switch off this function.

Touch control function

◆Intelligent protocol operation

( it is valid when connect the intelligent module and exchange to current

protocol )

1.After motor stopping, motor reversal for 1-5 times, then pull the curtain manually.

2.When stop at any position , wait for 1-2 seconds, open or close the curtain by manual.

Intelligent protocol

① Allows manual activation ② ban manual activation

◆Release function

Press [SW1] button ,red LED light flash 1-5

times

Open the motor bottom, press [SW1] for 3 s-

econds, the blue light LED on, enter into ex-

change status.

Hotel management function

③.After the touch control function allowed , motor stop for 5 seconds, pull the

curtain on open or close direction, motor will open or close automatically.

④.Touch control function is allowed in EXW mode.

Press [programming button] to confirm, exch-

ange intelligent protocol done, blue light LED

off, according to the current protocol, the red

LED flash 1- 5 times.

◆Exchange intelligent protocol

Short time Press [programming button] for 4

times, and then long time press programming

button for 3 seconds, the red Led light flash 1 time.The blue LED flash for 10 times after

adding net successfully.

Short time Press programming button for 3 tim-

es, long time press programming button for 3

seconds, the red Led light flash 1 time.The red

and blue LED flash alternately after clearing

net successfully.

① Add net ② Clear net

③.Support open, stop, close control, percent control, response to open, stop,

close and percent status feedback.

④.Support manual operation, direction change and delete limit function.1.The third port which close to LED , from the high voltage to low voltage, close the curtain.

2.The third port which close to LED , from the low voltage to high voltage, open the curtain.

Press channel setting for 5 seconds, enter in-

to speed change status, LED light on.

Press [open] button for 5 seconds, choose

110 rpm;

Press [stop] button for 5 seconds, choose

90 rpm;

Press [close] button for 5 seconds, choose

70 rpm;

LED light flash 3 times and then light off.

Choose speed ( EXW speed is 70 rpm )

5S

5S

User instructions

MP60-2.0/70EA

5S

5S

4S

4S

4S

4S

Switch control

1.Brown and blue wire connected with 220V AC,black wire not connected,open the curtain.

Cut off the connection between brown wire and 220V AC,stop the curtain

2.Black and blue wire connected with 220V,black wire not connected,close the curtain.

Cut off the connection between brown wire and 220V AC,stop the curtain

Live L WhiteOpen L1 BlackClose L2 BrownNeutral N Blue

Connection diagram

Port definition

1.GND ( Ground)

2.External switch (open )

3.External switch (close )

4.Room card checking ( hotel management )

5.A+(485)

6.B- (485)

3SSW1

EXW status

Tuya wifi universal protocol , flash 1

time

RAEX RS485

protocol, baud rate

9600 flash twice.

Exchange intelligent protocol

RAEX RS485 protocol, baud rate

19200 flash 3 times.

Z wave protocol,

flash 4 times

SW1

Exchange intelligent protocol

Exchange intelligent protocol

RAEX universal

intelligent protocol,

flash 5 times

SW1

Exchange intelligent protocol

Exchange intelligent protocol

① ②

(back) (back)

(back)

Please read the specification carefully before installation or use.

Please insta l l and ad just the product by profess ionals .

RAEX MACHINERY LIMITED

GUANGDONG RAEX INTELLIGENT TECHNOLOGY CO.,LTD.

RAEX MACHINERY LIMITED

-Unit A,2/F,On Wah Industrial Building,41 43 Au Pui Street,Fo Tan,Shatin, N.T.,HongKong.

- -Tel: 00852 26909728 Fax: 00852 26900018

GUANGDONG RAEX INTELLIGENT TECHNOLOGY CO.,LTD.

XiLi Industrial Park,DongChong Town,Nansha district,

CuangZhou,China(Post Code:511475)

- -Tel: 008620 22916189 Fax: 008620 22916154