Quick Guide Supra R22 / Supra R12 Cat. No. : SU-R22 / SU-R12 Display & Control Panel Pulse PULSE xg VIEW SETTINGS Start Stop Display Screen Status of RPM / RCF / Time / Temperature / Rotor ID / ACC / DEC / Program Setting Speed Press once : Setting RPM Press twice : Setting RCF Setting Time Up to < 100 hr Continuous run (00:00) Lid Open Program Save / Call Saving a program (up to 100) Calling up a program Setting the Rotor ID manually When rotor id is not identified automatically, enter the rotor ID. manually Max. RPM : 22,000 rpm Max. RCF : 57,358 xg Max. RPM : 12,000 rpm Max. RCF : 22,265 xg Supra R12 Supra R22 Press the Pulse button Enter the desired speed (See ‘Setting Run Parameters’) Serial No. Installation Date Saving / Calling Up a Program Press a parameter to be changed Press the Enter button Enter the desired values on the keypad Enter the desired program number on the keypad Press the Save or call button Setting Run Parameters (RPM / RCF / Time / Temperature / ACC / DEC) Press the Enter button Press the Temp. limit button Press the Enter button Temperature range that stops operation when the temperature is lower or higher than the set temperature. Enter the desired temperature range on the keypad Setting Temp. Limit View Settings Verifying the setting parameters during centrifugation Pulse After reaching the set speed, the centrifugation is decelated and stopped Setting ACC / DEC Rate ACC (0 ~ 9 steps, Max.9) DEC (0 ~ 9 steps, Natural DEC.0) Setting Temperature Setting temperature ( -10℃ ~ 40℃) Setting temp. limit 2 3 1 5 6 4 8 9 7 0 ±
2

Quick Guide Supra R22 / Supra R12...Supra R12 Supra R22 Press the Pulse button Enter the desired speed (See ‘Setting Run Parameters’) Serial No. Installation Date Saving / Calling

Mar 13, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Quick Guide Supra R22 / Supra R12...Supra R12 Supra R22 Press the Pulse button Enter the desired speed (See ‘Setting Run Parameters’) Serial No. Installation Date Saving / Calling

Quick Guide Supra R22 / Supra R12Cat. No. : SU-R22 / SU-R12

Display & Control Panel

Pulse

PULSE

xg

VIEWSETTINGS

Start Stop

Display ScreenStatus of RPM / RCF / Time / Temperature / Rotor ID / ACC / DEC / Program

Setting SpeedPress once : Setting RPMPress twice : Setting RCF

Setting TimeUp to < 100 hr Continuous run (00:00)

Lid Open

Program Save / Call Saving a program (up to 100)

Calling up a program

Setting the Rotor ID manually When rotor id is not identified automatically, enter the rotor ID. manually

Max. RPM : 22,000 rpm

Max. RCF : 57,358 xg

Max. RPM : 12,000 rpm

Max. RCF : 22,265 xg Supra R12

Supra R22

Press the Pulse button

Enter the desired speed (See ‘Setting Run

Parameters’)

Serial No. Installation Date

Saving / Calling Up a Program

Press a parameterto be changed

Press theEnter button

Enter the desired values on the keypad

Enter the desired program number on

the keypad

Press theSave or call button

Setting Run Parameters(RPM / RCF / Time / Temperature / ACC / DEC)

Press theEnter button

Press theTemp. limit button

Press theEnter button

Temperature range that stops operation when the temperature is lower or higher than the set temperature.

Enter the desired temperature range

on the keypad

Setting Temp. Limit

View SettingsVerifying the setting parameters during centrifugation

PulseAfter reaching the set speed, the centrifugation is decelated and stopped

Setting ACC / DEC Rate ACC (0 ~ 9 steps, Max.9)

DEC (0 ~ 9 steps, Natural DEC.0)

Setting Temperature Setting temperature ( -10℃ ~ 40℃)

Setting temp. limit

2 31

5 64

8 97

Page 2: Quick Guide Supra R22 / Supra R12...Supra R12 Supra R22 Press the Pulse button Enter the desired speed (See ‘Setting Run Parameters’) Serial No. Installation Date Saving / Calling

Connect the device to voltage

sources, which correspond to the

electrical requirements on the label

attached to the device.

Check the wall outlet is earth-

grounded, surge-protected and

can supply enough power.

Connect the power cable to the

distribution box, or install the plug

and socket that are packed with

the device.

Switch off the device after use.

Unplug the power plug before

cleaning or unused for a long

period of time.

Check the Line Voltage Grounded Outlet Power Connection Switch Off the Device

Quick Guide Supra R22 / Supra R12Cat. No. : SU-R22 / SU-R12

Maintenance

Electrical safety

A2.0-36

A10-12

A15-12

A15c-12

A50-6

A50c-6

36 x 1.5/2.0 mL / Max. 18k

12 x 10 mL / Max. 22k

12x 15 mL / Max. 22k

12 x 15 mL conical / Max. 17k

6 x 50 mL / Max. 22k

6 x 50 mLconical / Max. 17k

6 x 250 mL / Max. 12k

6 x 500 mL / Max. 10k

4 x 1,000 mL / Max. 8k

6 x 1,000 mL / Max. 7k

A250-6

A500-6

A1000-4

A1000-6

Rotors

Allow a safety clearance of 30 cm around the centrifuge during operation.

Remove Dust Empty the Condensation WaterAllow a Safety Clearance of 30 cmEmergency Lid Open

30 cm

30 cm30 cm

If the centrifuge lid cannot be opened, insert the provided T-wrench into the emergency release hole on the right side of the device and press it. (Before activating emergency open, switch off the device and wait for the rotor to stop.)

Remove any dust from the ventilation slits on the right sideof the device.

Empty the condensation water regularly by removing the drain cap on the left side of the device.

8 x 50 mL / Max. 20k

6 x 85 mL / Max. 20k

6 x 250 mL / Max. 12k

6 x 500 mL / Max. 9k

4 x 1,000 mL / Max. 8k

A50-8

A85-6

A250-6

A500-6

A1000-4

Supra R22 Supra R12

Cautions for Use

Inspect the rotor, chamber, rotor & accessories for foreign objects.

Check the Chamber & Accessories

Wipe up the moisture in the chamber with a dry cloth after use. Keep the lid open when not in use.

Clean the chamber and rotor by wiping with a cloth soaked in mild detergent and dry completely.

Keep the Chamber Dry

Cleaning

Load tubes symmetrically into the rotor with identical amount.

Load Tubes Symmetrically

Check the rotor, buckets and tubes are free of scratch and crack before operation.

Check the Accessories for Abnormalities

After relocating the device or loading the rotor, balance them by using a leveler. If necessary, level the device by adjusting the ‘Leveling foot’ on the bottom of the device.

Balancing the Centrifuge and Rotor

3.4KVA (Supra R22)

3.0KVA (Supra R12)

220~240V 50/60Hz

Rev.1

Proudly made by Jiyoung Shim, Hyewon Jeong

Order & Inquiry l +82-2-3472-0727 l [email protected] l www.ihanil.com

Service l +82-2-3452-8966 l [email protected]

Before Operation After Operation