Top Banner
Petrone Oleodinamica s.r.l. The Company was set up by Vito Petrone in Gravina in Puglia in 1953 as a workshop to repair farming and industrial vehicles. In 1968, the Company began to develop an interest in the world of hydraulics, specialising in the assembly of automatic and timed lubrication systems for transport company trucks. Then, in the 80’s, the Company started to dedicate itself to the assembly of lifting systems, automation and hydrostatic transmission. In March 2001, under the management of Cassandra and Vitantonio Petrone, Petrone Oleodinamica S.r.l. moved to a new, large structure in the industrial area of Gravina in Puglia, spread over 4000 square metres, with several, different service areas: a spare parts warehouse, a repair shop, a design area, a check and measurement area, a production area and a finished products warehouse, as well as a large area for the management, administrative and technical offices. In September 2003, Petrone Oleodinamica S.rl. presented the group 2 gear pump at the 67th “Fiera del Levante”. The pump was built at the Company, using a wide and modern range of advanced machinery in the sector. All of Petrone Oleodinamica S.r.l.’s pumps are tested thoroughly on a new generation test bed. Only those, which conform, are stamped and stored in the finished products warehouse. After 50 years of commitment in the field of hydraulics, it is now the only company in the south to produce gear pumps. In November 2003, the Company was certified ISO 9001/00 and ISO 14001/96, providing a further guarantee of the quality of its production cycle, and protection for the environment.
16

Petrone Oleodinamica s.r.l. · Petrone Oleodinamica THECHNICAL INFORMATION SERIES PNP 2 Pump Displacement: 4 – 6 – 8 – 11 – 14 – 16 – 20 – 26 cm3 / rev. Speed range

Aug 27, 2018

Download

Documents

ngokiet
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Petrone Oleodinamica s.r.l. · Petrone Oleodinamica THECHNICAL INFORMATION SERIES PNP 2 Pump Displacement: 4 – 6 – 8 – 11 – 14 – 16 – 20 – 26 cm3 / rev. Speed range

Petrone Oleodinamica s.r.l.

The Company was set up by Vito Petrone in Gravina in Puglia in 1953 as a workshop to

repair farming and industrial vehicles.

In 1968, the Company began to develop an interest in the world of hydraulics, specialising in

the assembly of automatic and timed lubrication systems for transport company trucks.

Then, in the 80’s, the Company started to dedicate itself to the assembly of lifting systems,

automation and hydrostatic transmission.

In March 2001, under the management of Cassandra and Vitantonio Petrone, Petrone

Oleodinamica S.r.l. moved to a new, large structure in the industrial area of Gravina in Puglia,

spread over 4000 square metres, with several, different service areas: a spare parts warehouse, a

repair shop, a design area, a check and measurement area, a production area and a finished products

warehouse, as well as a large area for the management, administrative and technical offices.

In September 2003, Petrone Oleodinamica S.rl. presented the group 2 gear pump at the 67th

“Fiera del Levante”. The pump was built at the Company, using a wide and modern range of

advanced machinery in the sector.

All of Petrone Oleodinamica S.r.l.’s pumps are tested thoroughly on a new generation test

bed. Only those, which conform, are stamped and stored in the finished products warehouse. After

50 years of commitment in the field of hydraulics, it is now the only company in the south to

produce gear pumps.

In November 2003, the Company was certified ISO 9001/00 and ISO 14001/96, providing a

further guarantee of the quality of its production cycle, and protection for the environment.

Page 2: Petrone Oleodinamica s.r.l. · Petrone Oleodinamica THECHNICAL INFORMATION SERIES PNP 2 Pump Displacement: 4 – 6 – 8 – 11 – 14 – 16 – 20 – 26 cm3 / rev. Speed range

Petrone Oleodinamica

THECHNICAL INFORMATION

SERIES PNP 2

Pump Displacement: 4 – 6 – 8 – 11 – 14 – 16 – 20 – 26 cm3 / rev. Speed range

400 – 4000 rpm Efficiency:

volumetric ηv>98%; mechanical ηm>95%; overall ηt>90% Suitable to run under severe conditions of:

pressure, speed and temperature. High pressure capability

Up to 270 bar maximum continuous operating pressure for capacities up to 11 cm3 (see performance table for further details).

High temperature seal kit available T>85° C

6 main different mounting configurations (01 – 02 – 03 – 04 – 05 – 06) Flange, shaft ends and porting are fully interchangeable with the main Standards of the market, and with all the other “range 2” Petrone Oleodinamica S.r.l. gear pumps.

Large standardization of components: Seal kit, cover, bearing, gears, are common to all the configurations.

Tandem options available Possibility to be mounted on all the rear pads of all the Petrone gear pumps.

All PNP 2 pumps may work as unidirectional motors (In the opposite sense of rotation compared to the one of a pump), without any change of components.

Easy to change sense of rotation, drive shaft, front flange, or from single to multiple pump stage.

Page 3: Petrone Oleodinamica s.r.l. · Petrone Oleodinamica THECHNICAL INFORMATION SERIES PNP 2 Pump Displacement: 4 – 6 – 8 – 11 – 14 – 16 – 20 – 26 cm3 / rev. Speed range

Petrone Oleodinamica

USEFUL FORMULAS

Flow: The calculate the output flow “Q” delivered by a pump at a certain speed “n”.:

V . n Q = 1000

. ηv [ l / min]

V = Pump capacity [ cm3 / rev ] n = Speed [ r.p.m.] ηv = Volumetric Efficiency (assume, for general calculations 0,93-0,97 from 1000 to

3000 r.p.m. Power-Efficiencies Hydraulic Power: the hydraulic power Wh transferred to an oil flow Q due to a pressure variation Δp is given by the: Mechanical Power: the mechanical power Wm absorbed from a pump shaft is given by the following: Torque To calculate the torque Mt necessary to run a pump under a differential pressure Δp è: Δp = Differential pressure between outlet and inlet [ bar ] Rm = Mechanical efficiency of the pump (assume, for general calculations 0.85 at cold

start, 0.9 on steady running).

Q . Δp _ Wh = 600 [kW]

Mt . n . π _ Wm =30 . 1000

[kW]

V . Δp _ Mt = 20 . π . ηm

[N . m]

Page 4: Petrone Oleodinamica s.r.l. · Petrone Oleodinamica THECHNICAL INFORMATION SERIES PNP 2 Pump Displacement: 4 – 6 – 8 – 11 – 14 – 16 – 20 – 26 cm3 / rev. Speed range

Petrone Oleodinamica

INSTRUCTIONS FOR USE

To achieve the best in terms of performance and life, it is necessary to meet the catalogue specifications, but it is also necessary to follow some general rules, and we would like to recommend the following : Put much care in designing the hydraulic circuit as a the whole, specially the suction

line, the choice and the position of the safety relief valves, of the filters, and dimensioning reservoir and heat exchangers.

Ensure a correct and frequent cleaning and maintenance of circuit and hydraulic

fluid. Equip the circuit with suitable alarm and safety devices, as well as reliable

instrumentations. Avoid as much as possible cold starting, under load, specially at low room-

temperatures, and after long standstills. Repeated starts under load are not recommended.

At low speeds, avoid to use the pump at high pressure for long periods, or in

excessively intermittent duties. In these cases a multiplier gearbox is recommended. A proper oil choice is a major factor, as well as a correct thermal protection.

Drive the pump whit a suitable power take off (PTO).

OPERATING REQUIREMENTS

Max. inlet vacuum: 0.3 bar Max inlet pressure: 3 bar

Environmenntal temperature range : - 15° C ÷ 80° C

Page 5: Petrone Oleodinamica s.r.l. · Petrone Oleodinamica THECHNICAL INFORMATION SERIES PNP 2 Pump Displacement: 4 – 6 – 8 – 11 – 14 – 16 – 20 – 26 cm3 / rev. Speed range

Petrone Oleodinamica

HYDRAULIC FLUID

Recommended: Mineral base hydraulic oils HLP HV (DIN 51514) Allowed engine oils with additives preventing from oxidation, wear and

foaming.

Fluid Temperature

Max. operating: 80° C

Recommended: 30° C ÷ 60° C Temperature over 80 °C are allowed but using FPM (Viton) seals.

Viscosity

Recommended range: 20 ÷ 65 cSt Max. at cold starting: 1000 cSt

Fluid cleanliness and filtering The recommended degrees of filtration are:

Inlet: 80 ÷ 100 µm Return the: up to 170 bar 25 µm over 170 bar 10 µm

Use quality filters, with indicators and alarm. Avoid as much as possible to use filter with by-pass valve.

Page 6: Petrone Oleodinamica s.r.l. · Petrone Oleodinamica THECHNICAL INFORMATION SERIES PNP 2 Pump Displacement: 4 – 6 – 8 – 11 – 14 – 16 – 20 – 26 cm3 / rev. Speed range

Petrone Oleodinamica

HYDRAULIC CIRCUIT AND INSTALLATION

Rules for dimensioning the circuit: Avoid sharp restrictions and small radium bends. Recommended fluid speed in inlet line: 0,5 ÷ 1,6 m / sec. Recommended fluid speed in delivery line: 2 ÷ 6 m / sec. Recommended fluid speed in return line: 1,5 ÷ 3 m / sec.

For further details and information regarding the applications of our pumps, please contacts PETRONE OLEODINAMICA S.r.l..

Page 7: Petrone Oleodinamica s.r.l. · Petrone Oleodinamica THECHNICAL INFORMATION SERIES PNP 2 Pump Displacement: 4 – 6 – 8 – 11 – 14 – 16 – 20 – 26 cm3 / rev. Speed range
Page 8: Petrone Oleodinamica s.r.l. · Petrone Oleodinamica THECHNICAL INFORMATION SERIES PNP 2 Pump Displacement: 4 – 6 – 8 – 11 – 14 – 16 – 20 – 26 cm3 / rev. Speed range
Page 9: Petrone Oleodinamica s.r.l. · Petrone Oleodinamica THECHNICAL INFORMATION SERIES PNP 2 Pump Displacement: 4 – 6 – 8 – 11 – 14 – 16 – 20 – 26 cm3 / rev. Speed range
Page 10: Petrone Oleodinamica s.r.l. · Petrone Oleodinamica THECHNICAL INFORMATION SERIES PNP 2 Pump Displacement: 4 – 6 – 8 – 11 – 14 – 16 – 20 – 26 cm3 / rev. Speed range
Page 11: Petrone Oleodinamica s.r.l. · Petrone Oleodinamica THECHNICAL INFORMATION SERIES PNP 2 Pump Displacement: 4 – 6 – 8 – 11 – 14 – 16 – 20 – 26 cm3 / rev. Speed range
Page 12: Petrone Oleodinamica s.r.l. · Petrone Oleodinamica THECHNICAL INFORMATION SERIES PNP 2 Pump Displacement: 4 – 6 – 8 – 11 – 14 – 16 – 20 – 26 cm3 / rev. Speed range
Page 13: Petrone Oleodinamica s.r.l. · Petrone Oleodinamica THECHNICAL INFORMATION SERIES PNP 2 Pump Displacement: 4 – 6 – 8 – 11 – 14 – 16 – 20 – 26 cm3 / rev. Speed range
Page 14: Petrone Oleodinamica s.r.l. · Petrone Oleodinamica THECHNICAL INFORMATION SERIES PNP 2 Pump Displacement: 4 – 6 – 8 – 11 – 14 – 16 – 20 – 26 cm3 / rev. Speed range
Page 15: Petrone Oleodinamica s.r.l. · Petrone Oleodinamica THECHNICAL INFORMATION SERIES PNP 2 Pump Displacement: 4 – 6 – 8 – 11 – 14 – 16 – 20 – 26 cm3 / rev. Speed range