    BSS Telecom Parameters Catalogue: Release B9

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA

  • BSC parameters

    Logical name A_ECNO_HO HMI name A_ECNO_HO B8 No B9 Yes TRX nb No Definition Window size for Ec/No level averages for 2G to 3G handover Cell Type Yes Sub-syste BSC RMS No Instance cell Rec None Application 2G-3G Categor Site (CAE) reference domain y Spec Radio measurements data processing OMC-R Changeable Type Number Unit Samfr reference access Coding rules -- Min value 1 Coded 1 Mandatory -- Max 31 Coded 31 rulesRecommended -- Coded Def 8 Recommended -- Def value 8 Coded Def 8 rules External -- comment Internal This parameter is a MR4 parameter. comment CT: Depends on Cell Type and BTS Type

    Logical name A_LEV_HO HMI name A_LEV_HO B8 Yes B9 Yes TRX nb No Definition Window size for level averages for handover. Cell Type Yes Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Radio measurements data processing OMC-R Changeable Type Number Unit Samfr reference access Coding rules -- Min value 1 Coded 1 Mandatory A_LEV_HO + W_LEV_HO < 32 Max 31 Coded 31 rulesRecommended A_LEV_HO = 2 x A_LEV_PC. A_PBGT_HO = 2 x A_LEV_HO Coded Def 8 Recommended A_LEV_HO = 2 x A_LEV_PC. A_PBGT_HO = 2 x A_LEV_HO Def value 8 Coded Def 8 rules External -- comment Internal CT: Depends on Cell Type and BTS Type comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 2

  • Logical name A_LEV_MCHO HMI name A_LEV_MCHO B8 Yes B9 Yes TRX nb No Definition Window size for level averages for microcell handover. Cell Type Yes Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Radio measurements data processing OMC-R Changeable Type Number Unit Samfr reference access Coding rules -- Min value 1 Coded 1 Mandatory A_LEV_MCHO + W_LEV_MCHO < 16 Max 15 Coded 15 rulesRecommended -- Coded Def 2 Recommended -- Def value 2 Coded Def 2 rules External -- comment Internal Meaningful only for cells where: Cell_type = Microcell comment

    Logical name A_LEV_PC HMI name A_LEV_PC B8 Yes B9 Yes TRX nb No Definition Window size for level averages for power control. Cell Type No Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Radio measurements data processing OMC-R Changeable Type Number Unit Samfr reference access Coding rules -- Min value 1 Coded 1 Mandatory A_LEV_PC + W_LEV_PC < 32 Max 31 Coded 31 rulesRecommended A_LEV_HO = 2 x A_LEV_PC Coded Def 4 Recommended A_LEV_HO = 2 x A_LEV_PC Def value 4 Coded Def 4 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 3

  • Logical name A_PBGT_DR HMI name A_PBGT_DR B8 Yes B9 Yes TRX nb No Definition Window size for neighbour cell level averages for forced directed retry. Cell Type No Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Radio measurements data processing OMC-R Changeable Type Number Unit Samfr reference access Coding rules -- Min value 1 Coded 1 Mandatory -- Max 15 Coded 15 rulesRecommended -- Coded Def 4 Recommended -- Def value 4 Coded Def 4 rules External -- comment Internal -- comment

    Logical name A_PBGT_HO HMI name A_PBGT_HO B8 Yes B9 Yes TRX nb No Definition Window size for averaging neighbour cell levels and averaging current cell levels for power Cell Type Yes budget calculation. Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Radio measurements data processing OMC-R Changeable Type Number Unit Samfr reference access Coding rules -- Min value 1 Coded 1 Mandatory A_PBGT_HO + W_PBGT_HO < 32 Max 31 Coded 31 rulesRecommended A_PBGT_HO = 2 x A_LEV_HO Coded Def 16 Recommended A_PBGT_HO = 2 x A_LEV_HO Def value 16 Coded Def 16 rules External should be set to 6 in suburban area, to 8 in urban area and to 12 in rural area comment Internal CT: Depends on Cell Type and BTS Type comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 4

  • Logical name A_QUAL_CA_FR_HR HMI name A_QUAL_CA_FR_HR B8 Yes B9 Yes TRX nb No Definition Quality averaging window size for AMR FR-to-HR channel adaptation. Cell Type No Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Radio measurements data processing OMC-R Changeable Type Number Unit Samfr reference access Coding rules step size = 1 Samfr Min value 1 Coded 1 Mandatory A_QUAL_CA_FR_HR >= A_QUAL_CA_HR_FR Max 61 Coded 61 rulesRecommended -- Coded Def 61 Recommended -- Def value 61 Coded Def 61 rules External -- comment Internal -- comment

    Logical name A_QUAL_CA_HR_FR HMI name A_QUAL_CA_HR_FR B8 Yes B9 Yes TRX nb No Definition Quality averaging window size for AMR HR-to-FR channel adaptation. Cell Type No Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Radio measurements data processing OMC-R Changeable Type Number Unit Samfr reference access Coding rules step size = 1 Samfr Min value 1 Coded 1 Mandatory A_QUAL_CA_FR_HR >= A_QUAL_CA_HR_FR Max 61 Coded 61 rulesRecommended -- Coded Def 8 Recommended -- Def value 8 Coded Def 8 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 5

  • Logical name A_QUAL_HO HMI name A_QUAL_HO B8 Yes B9 Yes TRX nb No Definition Window size for quality averages for handover. Cell Type Yes Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Radio measurements data processing OMC-R Changeable Type Number Unit Samfr reference access Coding rules -- Min value 1 Coded 1 Mandatory A_QUAL_HO + W_QUAL_HO < 32 Max 31 Coded 31 rulesRecommended A_QUAL_HO = 2 x A_QUAL_PC Coded Def 8 Recommended A_QUAL_HO = 2 x A_QUAL_PC Def value 8 Coded Def 8 rules External -- comment Internal CT: Depends on Cell Type and BTS Type comment

    Logical name A_QUAL_PC HMI name A_QUAL_PC B8 Yes B9 Yes TRX nb No Definition Window size for quality averages for power control. Cell Type No Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Radio measurements data processing OMC-R Changeable Type Number Unit Samfr reference access Coding rules -- Min value 1 Coded 1 Mandatory A_QUAL_PC + W_QUAL_PC < 32 Max 31 Coded 31 rulesRecommended A_QUAL_HO = 2 x A_QUAL_PC Coded Def 4 Recommended A_QUAL_HO = 2 x A_QUAL_PC Def value 4 Coded Def 4 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 6

  • Logical name A_RANGE_HO HMI name A_RANGE_HO B8 Yes B9 Yes TRX nb No Definition Window size for distance averages. Cell Type No Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Radio measurements data processing OMC-R Changeable Type Number Unit Samfr reference access Coding rules -- Min value 1 Coded 1 Mandatory -- Max 31 Coded 31 rulesRecommended -- Coded Def 8 Recommended -- Def value 8 Coded Def 8 rules External -- comment Internal -- comment

    Logical name A_TRAFFIC_LOAD HMI name A_TRAFFIC_LOAD B8 Yes B9 Yes TRX nb Yes Definition Window size for load averages. Cell Type No Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Resource allocation & management OMC-R Changeable Type Number Unit None reference access Coding rules -- Min value 1 Coded 1 Mandatory -- Max 16 Coded 16 rulesRecommended -- Coded Def 12 Recommended -- Def value 12 Coded Def 12 rules External -- comment Internal TRXnb: Depends on TRX number comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 7

  • Logical name AC_0 HMI name AC 0 B8 Yes B9 Yes TRX nb No Definition Indicates if Access Class 0 is barred. Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 04.08 Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Flag Unit None reference access Coding rules 0: not barred, 1: barred Min value 0 Coded 0 Mandatory -- Max 1 Coded 1 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal -- comment

    Logical name AC_1 HMI name AC 1 B8 Yes B9 Yes TRX nb No Definition Indicates if Access Class 1 is barred. Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 04.08 Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Flag Unit None reference access Coding rules 0: not barred, 1: barred Min value 0 Coded 0 Mandatory -- Max 1 Coded 1 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 8

  • Logical name AC_11 HMI name AC 11 B8 Yes B9 Yes TRX nb No Definition Indicates if Access Class 11 is barred. Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 04.08 Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Flag Unit None reference access Coding rules 0: not barred, 1: barred Min value 0 Coded 0 Mandatory -- Max 1 Coded 1 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal -- comment

    Logical name AC_12 HMI name AC 12 B8 Yes B9 Yes TRX nb No Definition Indicates if Acces