  • BSC parameters

    Logical name A_ECNO_HO HMI name A_ECNO_HO B8 No B9 Yes TRX nb No Definition Window size for Ec/No level averages for 2G to 3G handover Cell Type Yes Sub-syste BSC RMS No Instance cell Rec None Application 2G-3G Categor Site (CAE) reference domain y Spec Radio measurements data processing OMC-R Changeable Type Number Unit Samfr reference access Coding rules -- Min value 1 Coded 1 Mandatory -- Max 31 Coded 31 rulesRecommended -- Coded Def 8 Recommended -- Def value 8 Coded Def 8 rules External -- comment Internal This parameter is a MR4 parameter. comment CT: Depends on Cell Type and BTS Type

    Logical name A_LEV_HO HMI name A_LEV_HO B8 Yes B9 Yes TRX nb No Definition Window size for level averages for handover. Cell Type Yes Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Radio measurements data processing OMC-R Changeable Type Number Unit Samfr reference access Coding rules -- Min value 1 Coded 1 Mandatory A_LEV_HO + W_LEV_HO < 32 Max 31 Coded 31 rulesRecommended A_LEV_HO = 2 x A_LEV_PC. A_PBGT_HO = 2 x A_LEV_HO Coded Def 8 Recommended A_LEV_HO = 2 x A_LEV_PC. A_PBGT_HO = 2 x A_LEV_HO Def value 8 Coded Def 8 rules External -- comment Internal CT: Depends on Cell Type and BTS Type comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 2

  • Logical name A_LEV_MCHO HMI name A_LEV_MCHO B8 Yes B9 Yes TRX nb No Definition Window size for level averages for microcell handover. Cell Type Yes Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Radio measurements data processing OMC-R Changeable Type Number Unit Samfr reference access Coding rules -- Min value 1 Coded 1 Mandatory A_LEV_MCHO + W_LEV_MCHO < 16 Max 15 Coded 15 rulesRecommended -- Coded Def 2 Recommended -- Def value 2 Coded Def 2 rules External -- comment Internal Meaningful only for cells where: Cell_type = Microcell comment

    Logical name A_LEV_PC HMI name A_LEV_PC B8 Yes B9 Yes TRX nb No Definition Window size for level averages for power control. Cell Type No Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Radio measurements data processing OMC-R Changeable Type Number Unit Samfr reference access Coding rules -- Min value 1 Coded 1 Mandatory A_LEV_PC + W_LEV_PC < 32 Max 31 Coded 31 rulesRecommended A_LEV_HO = 2 x A_LEV_PC Coded Def 4 Recommended A_LEV_HO = 2 x A_LEV_PC Def value 4 Coded Def 4 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 3

  • Logical name A_PBGT_DR HMI name A_PBGT_DR B8 Yes B9 Yes TRX nb No Definition Window size for neighbour cell level averages for forced directed retry. Cell Type No Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Radio measurements data processing OMC-R Changeable Type Number Unit Samfr reference access Coding rules -- Min value 1 Coded 1 Mandatory -- Max 15 Coded 15 rulesRecommended -- Coded Def 4 Recommended -- Def value 4 Coded Def 4 rules External -- comment Internal -- comment

    Logical name A_PBGT_HO HMI name A_PBGT_HO B8 Yes B9 Yes TRX nb No Definition Window size for averaging neighbour cell levels and averaging current cell levels for power Cell Type Yes budget calculation. Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Radio measurements data processing OMC-R Changeable Type Number Unit Samfr reference access Coding rules -- Min value 1 Coded 1 Mandatory A_PBGT_HO + W_PBGT_HO < 32 Max 31 Coded 31 rulesRecommended A_PBGT_HO = 2 x A_LEV_HO Coded Def 16 Recommended A_PBGT_HO = 2 x A_LEV_HO Def value 16 Coded Def 16 rules External should be set to 6 in suburban area, to 8 in urban area and to 12 in rural area comment Internal CT: Depends on Cell Type and BTS Type comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 4

  • Logical name A_QUAL_CA_FR_HR HMI name A_QUAL_CA_FR_HR B8 Yes B9 Yes TRX nb No Definition Quality averaging window size for AMR FR-to-HR channel adaptation. Cell Type No Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Radio measurements data processing OMC-R Changeable Type Number Unit Samfr reference access Coding rules step size = 1 Samfr Min value 1 Coded 1 Mandatory A_QUAL_CA_FR_HR >= A_QUAL_CA_HR_FR Max 61 Coded 61 rulesRecommended -- Coded Def 61 Recommended -- Def value 61 Coded Def 61 rules External -- comment Internal -- comment

    Logical name A_QUAL_CA_HR_FR HMI name A_QUAL_CA_HR_FR B8 Yes B9 Yes TRX nb No Definition Quality averaging window size for AMR HR-to-FR channel adaptation. Cell Type No Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Radio measurements data processing OMC-R Changeable Type Number Unit Samfr reference access Coding rules step size = 1 Samfr Min value 1 Coded 1 Mandatory A_QUAL_CA_FR_HR >= A_QUAL_CA_HR_FR Max 61 Coded 61 rulesRecommended -- Coded Def 8 Recommended -- Def value 8 Coded Def 8 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 5

  • Logical name A_QUAL_HO HMI name A_QUAL_HO B8 Yes B9 Yes TRX nb No Definition Window size for quality averages for handover. Cell Type Yes Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Radio measurements data processing OMC-R Changeable Type Number Unit Samfr reference access Coding rules -- Min value 1 Coded 1 Mandatory A_QUAL_HO + W_QUAL_HO < 32 Max 31 Coded 31 rulesRecommended A_QUAL_HO = 2 x A_QUAL_PC Coded Def 8 Recommended A_QUAL_HO = 2 x A_QUAL_PC Def value 8 Coded Def 8 rules External -- comment Internal CT: Depends on Cell Type and BTS Type comment

    Logical name A_QUAL_PC HMI name A_QUAL_PC B8 Yes B9 Yes TRX nb No Definition Window size for quality averages for power control. Cell Type No Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Radio measurements data processing OMC-R Changeable Type Number Unit Samfr reference access Coding rules -- Min value 1 Coded 1 Mandatory A_QUAL_PC + W_QUAL_PC < 32 Max 31 Coded 31 rulesRecommended A_QUAL_HO = 2 x A_QUAL_PC Coded Def 4 Recommended A_QUAL_HO = 2 x A_QUAL_PC Def value 4 Coded Def 4 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 6

  • Logical name A_RANGE_HO HMI name A_RANGE_HO B8 Yes B9 Yes TRX nb No Definition Window size for distance averages. Cell Type No Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Radio measurements data processing OMC-R Changeable Type Number Unit Samfr reference access Coding rules -- Min value 1 Coded 1 Mandatory -- Max 31 Coded 31 rulesRecommended -- Coded Def 8 Recommended -- Def value 8 Coded Def 8 rules External -- comment Internal -- comment

    Logical name A_TRAFFIC_LOAD HMI name A_TRAFFIC_LOAD B8 Yes B9 Yes TRX nb Yes Definition Window size for load averages. Cell Type No Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Resource allocation & management OMC-R Changeable Type Number Unit None reference access Coding rules -- Min value 1 Coded 1 Mandatory -- Max 16 Coded 16 rulesRecommended -- Coded Def 12 Recommended -- Def value 12 Coded Def 12 rules External -- comment Internal TRXnb: Depends on TRX number comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 7

  • Logical name AC_0 HMI name AC 0 B8 Yes B9 Yes TRX nb No Definition Indicates if Access Class 0 is barred. Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 04.08 Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Flag Unit None reference access Coding rules 0: not barred, 1: barred Min value 0 Coded 0 Mandatory -- Max 1 Coded 1 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal -- comment

    Logical name AC_1 HMI name AC 1 B8 Yes B9 Yes TRX nb No Definition Indicates if Access Class 1 is barred. Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 04.08 Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Flag Unit None reference access Coding rules 0: not barred, 1: barred Min value 0 Coded 0 Mandatory -- Max 1 Coded 1 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 8

  • Logical name AC_11 HMI name AC 11 B8 Yes B9 Yes TRX nb No Definition Indicates if Access Class 11 is barred. Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 04.08 Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Flag Unit None reference access Coding rules 0: not barred, 1: barred Min value 0 Coded 0 Mandatory -- Max 1 Coded 1 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal -- comment

    Logical name AC_12 HMI name AC 12 B8 Yes B9 Yes TRX nb No Definition Indicates if Access Class 12 is barred. Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 04.08 Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Flag Unit None reference access Coding rules 0: not barred, 1: barred Min value 0 Coded 0 Mandatory -- Max 1 Coded 1 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 9

  • Logical name AC_13 HMI name AC 13 B8 Yes B9 Yes TRX nb No Definition Indicates if Access Class 13 is barred. Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 04.08 Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Flag Unit None reference access Coding rules 0: not barred, 1: barred Min value 0 Coded 0 Mandatory -- Max 1 Coded 1 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal -- comment

    Logical name AC_14 HMI name AC 14 B8 Yes B9 Yes TRX nb No Definition Indicates if Access Class 14 is barred. Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 04.08 Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Flag Unit None reference access Coding rules 0: not barred, 1: barred Min value 0 Coded 0 Mandatory -- Max 1 Coded 1 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 10

  • Logical name AC_15 HMI name AC 15 B8 Yes B9 Yes TRX nb No Definition Indicates if Access Class 15 is barred. Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 04.08 Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Flag Unit None reference access Coding rules 0: not barred, 1: barred Min value 0 Coded 0 Mandatory -- Max 1 Coded 1 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal -- comment

    Logical name AC_2 HMI name AC 2 B8 Yes B9 Yes TRX nb No Definition Indicates if Access Class 2 is barred. Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 04.08 Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Flag Unit None reference access Coding rules 0: not barred, 1: barred Min value 0 Coded 0 Mandatory -- Max 1 Coded 1 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 11

  • Logical name AC_3 HMI name AC 3 B8 Yes B9 Yes TRX nb No Definition Indicates if Access Class 3 is barred. Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 04.08 Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Flag Unit None reference access Coding rules 0: not barred, 1: barred Min value 0 Coded 0 Mandatory -- Max 1 Coded 1 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal -- comment

    Logical name AC_4 HMI name AC 4 B8 Yes B9 Yes TRX nb No Definition Indicates if Access Class 4 is barred. Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 04.08 Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Flag Unit None reference access Coding rules 0: not barred, 1: barred Min value 0 Coded 0 Mandatory -- Max 1 Coded 1 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 12

  • Logical name AC_5 HMI name AC 5 B8 Yes B9 Yes TRX nb No Definition Indicates if Access Class 5 is barred. Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 04.08 Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Flag Unit None reference access Coding rules 0: not barred, 1: barred Min value 0 Coded 0 Mandatory -- Max 1 Coded 1 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal -- comment

    Logical name AC_6 HMI name AC 6 B8 Yes B9 Yes TRX nb No Definition Indicates if Access Class 6 is barred. Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 04.08 Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Flag Unit None reference access Coding rules 0: not barred, 1: barred Min value 0 Coded 0 Mandatory -- Max 1 Coded 1 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 13

  • Logical name AC_7 HMI name AC 7 B8 Yes B9 Yes TRX nb No Definition Indicates if Access Class 7 is barred. Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 04.08 Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Flag Unit None reference access Coding rules 0: not barred, 1: barred Min value 0 Coded 0 Mandatory -- Max 1 Coded 1 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal -- comment

    Logical name AC_8 HMI name AC 8 B8 Yes B9 Yes TRX nb No Definition Indicates if Access Class 8 is barred. Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 04.08 Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Flag Unit None reference access Coding rules 0: not barred, 1: barred Min value 0 Coded 0 Mandatory -- Max 1 Coded 1 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 14

  • Logical name AC_9 HMI name AC 9 B8 Yes B9 Yes TRX nb No Definition Indicates if Access Class 9 is barred. Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 04.08 Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Flag Unit None reference access Coding rules 0: not barred, 1: barred Min value 0 Coded 0 Mandatory -- Max 1 Coded 1 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal -- comment

    Logical name AC_PRIORITY_LIST(priority=1) HMI name High Priority Access Class B8 Yes B9 Yes TRX nb No Definition List of access classes 11..15 and EC (=10) in their priority order. Ordering P1 Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Number Unit None reference access Coding rules Priority 1 is the highest priority, Priority 6 is the lowest priority, 10 (EC) is coded as 5, 11 Min value 10 Coded 5 (access class 11) is coded as 0, 12 (access class 12) is coded as 1, 13 (access class 13) is coded as 2, 14 (access class 14) is coded as 3, 15 (access class 15) is coded as 4. Mandatory -- Max 15 Coded 4 rulesRecommended -- Coded Def 5 Recommended -- Def value 10 Coded Def 5 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 15

  • Logical name AC_PRIORITY_LIST(priority=2) HMI name High Priority Access Class B8 Yes B9 Yes TRX nb No Definition List of access classes 11..15 and EC (=10) in their priority order. Ordering P2 Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Number Unit None reference access Coding rules Priority 1 is the highest priority, Priority 6 is the lowest priority Min value 10 Coded 5 10 (EC) is coded as 5, 11 (access class 11) is coded as 0, 12 (access class 12) is coded as 1, 13 (access class 13) is coded as 2, 14 (access class 14) is coded as 3, 15 (access class 15) is coded as 4. Mandatory -- Max 15 Coded 4 rulesRecommended -- Coded Def 4 Recommended -- Def value 15 Coded Def 4 rules External -- comment Internal -- comment

    Logical name AC_PRIORITY_LIST(priority=3) HMI name High Priority Access Class B8 Yes B9 Yes TRX nb No Definition List of access classes 11..15 and EC (=10) in their priority order. Ordering P3 Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Number Unit None reference access Coding rules Priority 1 is the highest priority, Priority 6 is the lowest priority Min value 10 Coded 5 10 (EC) is coded as 5, 11 (access class 11) is coded as 0, 12 (access class 12) is coded as 1, 13 (access class 13) is coded as 2, 14 (access class 14) is coded as 3, 15 (access class 15) is coded as 4. Mandatory -- Max 15 Coded 4 rulesRecommended -- Coded Def 3 Recommended -- Def value 14 Coded Def 3 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 16

  • Logical name AC_PRIORITY_LIST(priority=4) HMI name High Priority Access Class B8 Yes B9 Yes TRX nb No Definition List of access classes 11..15 and EC (=10) in their priority order. Ordering P4 Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Number Unit None reference access Coding rules Priority 1 is the highest priority, Priority 6 is the lowest priority Min value 10 Coded 5 10 (EC) is coded as 5, 11 (access class 11) is coded as 0, 12 (access class 12) is coded as 1, 13 (access class 13) is coded as 2, 14 (access class 14) is coded as 3, 15 (access class 15) is coded as 4. Mandatory -- Max 15 Coded 4 rulesRecommended -- Coded Def 2 Recommended -- Def value 13 Coded Def 2 rules External -- comment Internal -- comment

    Logical name AC_PRIORITY_LIST(priority=5) HMI name High Priority Access Class B8 Yes B9 Yes TRX nb No Definition List of access classes 11..15 and EC (=10) in their priority order. Ordering P5 Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Number Unit None reference access Coding rules Priority 1 is the highest priority, Priority 6 is the lowest priority Min value 10 Coded 5 10 (EC) is coded as 5, 11 (access class 11) is coded as 0, 12 (access class 12) is coded as 1, 13 (access class 13) is coded as 2, 14 (access class 14) is coded as 3, 15 (access class 15) is coded as 4. Mandatory -- Max 15 Coded 4 rulesRecommended -- Coded Def 1 Recommended -- Def value 12 Coded Def 1 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 17

  • Logical name AC_PRIORITY_LIST(priority=6) HMI name High Priority Access Class B8 Yes B9 Yes TRX nb No Definition List of access classes 11..15 and EC (=10) in their priority order. Ordering P6 Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Number Unit None reference access Coding rules Priority 1 is the highest priority, Priority 6 is the lowest priority Min value 10 Coded 5 10 (EC) is coded as 5, 11 (access class 11) is coded as 0, 12 (access class 12) is coded as 1, 13 (access class 13) is coded as 2, 14 (access class 14) is coded as 3, 15 (access class 15) is coded as 4. Mandatory -- Max 15 Coded 4 rulesRecommended -- Coded Def 0 Recommended -- Def value 11 Coded Def 0 rules External -- comment Internal -- comment

    Logical name ADDITIONAL_RESELECT_PARAM HMI name ADDITIONAL_RESELECT_PARA B8 Yes B9 Yes TRX nb No Definition Indicates if C2 cell selection parameters are present in SYS_INFO_7&8 or SYS_INFO_4. M Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 04.08 Application GSM Categor Site (CAE) reference domain y Spec System information management OMC-R Displayed Type Flag Unit None reference access Coding rules 1bit; 0= the SI 4 rest octets, if present, are used to derive the value of PI and possibly C2 Min value 0 Coded 0 parameters. Mandatory -- Max 1 Coded 1 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal always set to 0 as SYS_INFO 7&8 are not used comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 18

  • Logical name ADDR_MON HMI name ADDR_MON B8 Yes B9 Yes TRX nb No Definition Time it takes to ADDR_TR to be reached to report an alarm. On timeout, the address error Cell Type No counter is reset. Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Network (CDE) reference domain y Spec LapD Management OMC-R None (DLS) Type Timer Unit sec reference access Coding rules step size = 0.1sec Min value 0 Coded 0 Mandatory -- Max 6553.5 Coded 65535 rulesRecommended -- Coded Def 150 Recommended -- Def value 15 Coded Def 150 rules External -- comment Internal -- comment

    Logical name ADDR_TR HMI name ADDR_TR B8 Yes B9 Yes TRX nb No Definition Address error threshold for alarm detection. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Network (CDE) reference domain y Spec LapD Management OMC-R None (DLS) Type Threshold Unit None reference access Coding rules -- Min value 1 Coded 1 Mandatory -- Max 255 Coded 255 rulesRecommended -- Coded Def 60 Recommended -- Def value 60 Coded Def 60 rules External -- comment Internal Internal BSS alarm, not OMC-R visualisation comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 19

  • Logical name AG_PREMPT_PCH HMI name AG_PREMPT_PCH B8 Yes B9 Yes TRX nb No Definition Flag to enable pre-emption of Paging sub-channels for Access Grant messages when there Cell Type No is one remaining free AGCH block. Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Paging and Access Grant Control OMC-R Changeable Type Flag Unit None reference access Coding rules 0 = disabled, 1 = enabled Min value 0 Coded 0 Mandatory Lets define the free AGCH blocks as the number of blocks remaining for the AGCH Max 1 Coded 1 rulesRecommended messages when the BCCH extended block and NCH blocks have been excluded. -- Recommended - If there is no free AGCH block then the flag is not used (pre-emption mandatory, default value -- rules 0 is not used by BTS ) - If there is only one free AGCH block then AG_PREMPT_PCH =1 or 0 (pre-emption allowed) - If there is more than one free AGCH then AG_PREMPT_PCH = 0 (pre-emption forbidden). Def value 0 Coded Def 0 External -- comment Internal When EN_VGCS is disabled : comment Free AGCH = BS_AG_BLKS_RES - BCCH_EXT

    When EN_VGCS is enabled Free AGCH = BS_AG_BLKS_RES - NUMBER_NCH_BLOCKS - BCCH_EXT

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 20

  • Logical name ALLOC_ANYWAY HMI name ALLOC_ANYWAY B8 Yes B9 Yes TRX nb No Definition Controls whether a queued request can be allocated on free resource at expiry of its queuing Cell Type No timer independently of the threshold NUM_TCH_EGNCY_HO. Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Resource allocation and management OMC-R Changeable Type Flag Unit None reference access Coding rules -- Min value 0 Coded 0 Mandatory -- Max 1 Coded 1 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External only relevant when NUM_TCH_EGNCY_HO > 0 comment Internal -- comment

    Logical name ALPHA (BSC) HMI name ALPHA B8 Yes B9 Yes TRX nb No Definition Alpha power control parameter. Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 04.08 Application GPRS Categor Site (CAE) reference domain y Spec System information management OMC-R Changeable Type Number Unit None reference access Coding rules Possible values are : 0.0 to 1.0 with step of 0.1respectively binary coded : 0000, 0001, 0010 Min value 0 Coded 0 1010 Mandatory Equal to ALPHA (MFS) Max 1 Coded 10 rulesRecommended -- Coded Def 10 Recommended -- Def value 1 Coded Def 10 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 21

  • Logical name AMR_FR_HYST HMI name AMR_FR_HYST B8 Yes B9 Yes TRX nb No Definition Hysteresis for AMR FR codec mode adaptation. Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 05.09 Application GSM Categor Site (CAE) reference domain y Spec Codec Adaptation OMC-R Changeable Type Number Unit dB reference access Coding rules step size=0.5 dB; 0 = 0.0 dB, 1 = 0.5 dB, , 15 = 7.5 dB Min value 0 Coded 0 Mandatory -- Max 7.5 Coded 15 rulesRecommended As the BTS is not able to compute C/I values higher than 16 dB, following rule is highly Coded Def 4 Recommended As the BTS is not able to compute C/I values higher than 16 dB, following rule is highly Def value 2 Coded Def 4 rules recommended : AMR_FR_HYST + AMR_FR_THR_i
  • Logical name AMR_FR_THR_1 HMI name AMR_FR_THR_1 B8 Yes B9 Yes TRX nb No Definition Threshold for AMR FR codec mode adaptation between lowest codec mode and second Cell Type No lowest codec mode. Sub-syste BSC RMS No Instance cell Rec GSM TS 05.09 Application GSM Categor Site (CAE) reference domain y Spec Codec Adaptation OMC-R Changeable Type Threshold Unit dB reference access Coding rules step size=0.5 dB; 0 = 0.0 dB, 1 = 0.5 dB, , 63 = 31.5 dB Min value 0 Coded 0 Mandatory AMR_FR_THR_1 = AMR_FR_THR_1 Max 31.5 Coded 63 rulesRecommended As the BTS is not able to compute C/I values higher than 16 dB, following rule is highly Coded Def 23 Recommended As the BTS is not able to compute C/I values higher than 16 dB, following rule is highly Def value 11.5 Coded Def 23 rules recommended : AMR_FR_HYST + AMR_FR_THR_2
  • Logical name AMR_FR_THR_3 HMI name AMR_FR_THR_3 B8 Yes B9 Yes TRX nb No Definition Threshold for AMR FR codec mode adaptation between third lowest codec mode and fourth Cell Type No lowest codec mode. Sub-syste BSC RMS No Instance cell Rec GSM TS 05.09 Application GSM Categor Site (CAE) reference domain y Spec Codec Adaptation OMC-R Changeable Type Threshold Unit dB reference access Coding rules step size=0.5 dB; 0 = 0.0 dB, 1 = 0.5 dB, , 63 = 31.5 dB Min value 0 Coded 0 Mandatory AMR_FR_THR_3 >= AMR_FR_THR_2 Max 31.5 Coded 63 rulesRecommended As the BTS is not able to compute C/I values higher than 16 dB, following rule is highly Coded Def 23 Recommended As the BTS is not able to compute C/I values higher than 16 dB, following rule is highly Def value 11.5 Coded Def 23 rules recommended : AMR_FR_HYST + AMR_FR_THR_3
  • Logical name AMR_HR_SUBSET HMI name AMR_HR_SUBSET B8 Yes B9 Yes TRX nb No Definition Bitmap (6 bits) defining the codec subset that shall be used for AMR HR calls (1 to 4 codecs). Cell Type No Sub-syste BSC RMS No Instance BSS Rec GSM TS 05.09 Application GSM Categor Site (CAE) reference domain y Spec Codec Adaptation OMC-R Changeable Type Reference Unit None reference access Coding rules Coded on 1 byte. Bit 8 (most significant) = Bit 7 = 0; bit 6 =1: 7,95 kbit/s is part of the subset; bit Min value 0 Coded 0 5=1: 7,40 kbit/s is part of the subset; bit 4=1: 6,70 kbit/s is part of the subset; bit 3=1: 5,90 kbit/s is part of the subset; bit 2=1: 5,15 kbit/s is part of the subset; bit 1 (least significant)=1: 4,75 kbit/s is part of the subset; Mandatory In one subset a maximum of 4 codec modes can be chosen (a maximum of 4 bits can be set Max 60 Coded 60 rulesRecommended to 1). The subset shall not contain only 7.4 kbit/s codec mode. The codec mode 7.95 kbit/s is -- Recommended not supported by Alcatel BSS. -- rules Def value 22 Coded Def 22 External Default value corresponds to the optimal default codec subset (7.4kbit/s, 5.9kbit/s, 5.15kbit/s). comment Internal -- comment

    Logical name AMR_HR_THR_1 HMI name AMR_HR_THR_1 B8 Yes B9 Yes TRX nb No Definition Threshold for AMR HR codec mode adaptation between lowest codec mode and second Cell Type No lowest codec mode. Sub-syste BSC RMS No Instance cell Rec GSM TS 05.09 Application GSM Categor Site (CAE) reference domain y Spec Codec Adaptation OMC-R Changeable Type Threshold Unit dB reference access Coding rules step size=0.5 dB; 0 = 0.0 dB, 1 = 0.5 dB, , 63 = 31.5 dB Min value 0 Coded 0 Mandatory AMR_HR_THR_1

  • Logical name AMR_HR_THR_2 HMI name AMR_HR_THR_2 B8 Yes B9 Yes TRX nb No Definition Threshold for AMR HR codec mode adaptation between second lowest codec mode and third Cell Type No lowest codec mode. Sub-syste BSC RMS No Instance cell Rec GSM TS 05.09 Application GSM Categor Site (CAE) reference domain y Spec Codec Adaptation OMC-R Changeable Type Threshold Unit dB reference access Coding rules step size=0.5 dB; 0 = 0.0 dB, 1 = 0.5 dB, , 63 = 31.5 dB Min value 0 Coded 0 Mandatory AMR_HR_THR_3 >= AMR_HR_THR_2 >= AMR_HR_THR_1 Max 31.5 Coded 63 rulesRecommended As the BTS is not able to compute C/I values higher than 16 dB, following rule is highly Coded Def 25 Recommended As the BTS is not able to compute C/I values higher than 16 dB, following rule is highly Def value 12.5 Coded Def 25 rules recommended : AMR_HR_HYST + AMR_HR_THR_2 = AMR_HR_THR_2 Max 31.5 Coded 63 rulesRecommended As the BTS is not able to compute C/I values higher than 16 dB, following rule is highly Coded Def 25 Recommended As the BTS is not able to compute C/I values higher than 16 dB, following rule is highly Def value 12.5 Coded Def 25 rules recommended : AMR_HR_HYST + AMR_HR_THR_3
  • Logical name AMR_START_MODE_FR HMI name AMR_START_MODE_FR B8 Yes B9 Yes TRX nb No Definition Indicates the codec used at the beginning of a FR AMR call, until codec mode adaptation is Cell Type No started by the BTS. Sub-syste BSC RMS No Instance BSS Rec GSM TS 05.09 Application GSM Categor Site (CAE) reference domain y Spec Codec Adaptation OMC-R Changeable Type Reference Unit None reference access Coding rules 0: implicit rule is used for initial codec mode; 1: lowest codec mode of the subset; 2: second Min value 0 Coded 0 lowest codec mode (used if the subset contains more than one codec mode); 3: third lowest codec mode (used if the subset contains more than two codec modes); 4: highest codec mode (used if the subset contains four codec modes) Mandatory -- Max 4 Coded 4 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal -- comment

    Logical name AMR_START_MODE_HR HMI name AMR_START_MODE_HR B8 Yes B9 Yes TRX nb No Definition Indicates the codec used at the beginning of a HR AMR call, until codec mode adaptation is Cell Type No started by the BTS. Sub-syste BSC RMS No Instance BSS Rec GSM TS 05.09 Application GSM Categor Site (CAE) reference domain y Spec Codec Adaptation OMC-R Changeable Type Reference Unit None reference access Coding rules 0: implicit rule is used for initial codec mode; 1: lowest codec mode of the subset; 2: second Min value 0 Coded 0 lowest codec mode (used if the subset contains more than one codec mode); 3: third lowest codec mode (used if the subset contains more than two codec modes); 4: highest codec mode (used if the subset contains four codec modes) Mandatory If AMR_START_MODE_HR is explicit (I.e. not equal to 0), the chosen codec mode shall not Max 4 Coded 4 rulesRecommended correspond to 7.40 kbit/s. Use codec mode 6.7 kbit/s as start mode for AMR HR should be avoided. Coded Def 0 rules Def value 0 Coded Def 0 External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 27

  • Logical name ATT (BSC) HMI name IMSI Attach/Detach B8 Yes B9 Yes TRX nb No Definition This flag indicates to the MS if IMSI Attach/detach procedure is allowed in the cell. Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 04.08 Application GSM Categor Site (CAE) reference domain y Spec System information management OMC-R Changeable Type Flag Unit None reference access Coding rules 0: not allowed, 1: allowed Min value 0 Coded 0 Mandatory Equal to ATT (MFS) Max 1 Coded 1 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal -- comment

    Logical name AUT_BAR HMI name AUTO_BAR_CELL B8 Yes B9 Yes TRX nb No Definition This flag enables/inhibits automatic barring of cell. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Overload control OMC-R Changeable Type Flag Unit None reference access Coding rules 0: disabled, 1: enabled Min value 0 Coded 0 Mandatory -- Max 1 Coded 1 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 28

  • Logical name AUTO_DSC HMI name AUTO_DSC B8 Yes B9 Yes TRX nb No Definition This flag enables/disables auto disconnection of LAPD links. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor System (CST) reference domain y Spec LapD Management OMC-R None (DLS) Type Flag Unit None reference access Coding rules 0: disabled 1: enabled Min value 0 Coded 0 Mandatory -- Max 1 Coded 1 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal -- comment

    Logical name B_NUM HMI name B_NUM B8 Yes B9 Yes TRX nb No Definition Number of BLOCK/UNBLOCK messages sent in one burst. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Reset circuit, blocking & unequipped circuit OMC-R Changeable Type Number Unit None reference access Coding rules -- Min value 1 Coded 1 Mandatory -- Max 35 Coded 35 rulesRecommended -- Coded Def 5 Recommended -- Def value 5 Coded Def 5 rules External Default value depends on MSC type. comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 29

  • Logical name BCC (BSC) HMI name BCC B8 Yes B9 Yes TRX nb No Definition BTS colour code of the cell. Cell Type No Sub-syste BSC RMS No Instance cell Rec Application GSM Categor Site (CAE) reference domain y Spec Radio measurements data processing OMC-R Changeable Type Number Unit None reference access Coding rules coded over 3 bits Min value 0 Coded 0 Mandatory Equal to BCC (MFS) Max 7 Coded 7 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External Default value depends on configuration. The value indicated here is for implementation purposes. comment Internal Transmitted to the BTS in the BTS_CONF_DATA message comment

    Logical name BCCH_EXT HMI name BCCH_EXT B8 Yes B9 Yes TRX nb No Definition This flag enables / disables the use of extended BCCH. Cell Type No Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Paging and Access Grant control OMC-R Changeable Type Flag Unit None reference access Coding rules 0: false, 1:true Min value 0 Coded 0 Mandatory -BCCH_EXT cannot be set to true if the associated BTS is a non-Evolium one. Max 1 Coded 1 rulesRecommended -When EN_SOLSA is enabled, the BCCH_EXT shall be set to true. The support of extended BCCH (parameter BCCH_EXT) is HIGHLY recommended in cells Recommended -When EN_VGCS is disabled : The support of extended BCCH (parameter BCCH_EXT) is HIGHLY recommended in cells rules . if BCCH_EXT = true, then BS_AG_BLKS_RES >= 1 having adjacent cells in several frequency bands and at least 18 adjacent frequencies -When EN_VGCS is enabled : within the same band. . If BCCH_EXT = false, then BS_AG_BLKS_RES >= NUMBER_NCH_BLOCKS . if BCCH_EXT = true, then BS_AG_BLKS_RES > NUMBER_NCH_BLOCKS Def value 0 Coded Def 0 External -- comment Internal The recommended rule is linked to the fact that when the SI2bis message is sent, it is recommended to activate the extended BCCH comment i) for 2G to 2G cell reselection to reduce the cell reselection duration ii) for 2G to 3G cell reselection to reduce the acquisition of the system information on 3G cells.

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 30

  • Logical name BCCH_FREQUENCY HMI name BCCH_FREQUENCY B8 Yes B9 Yes TRX nb No Definition Indicates the frequency used as BCCH. Cell Type No Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Handover Preparation OMC-R Virtual changeable Type Number Unit None reference access Coding rules -- Min value 0 Coded 0 Mandatory In a cell where FREQUENCY_RANGE = EGSM or EGSM-DCS1800, the BCCH ARFCN Max 1023 Coded 1023 rulesRecommended belonging to the G1 band may be selected by the operator, only if -- Recommended EGSM_RR_ALLOC_STRATEGY0, and, for the concentric cells, only in the outer zone. These -- rules restrictions do not apply to external cells. Def value None Coded Def External -- comment Internal - The ARFCN of the G1 band are in the range {975, 976, , 1023, 0}. comment - For an own cell, the BCCH frequency is deduced from the radio TS description.

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 31

  • Logical name BCCH_FREQUENCY(n) HMI name BCCH_ARFCN B8 No B9 Yes TRX nb No Definition Indicates the frequency used as BCCH. Cell Type No Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Handover Preparation OMC-R Changeable Type Number Unit None reference access Coding rules -- Min value 0 Coded 0 Mandatory - BCCH_FREQUENCY(n) = BCCH_ARFCN(n) Max 1023 Coded 1023 rulesRecommended - In a cell where FREQUENCY_RANGE = EGSM or EGSM-DCS1800, the BCCH ARFCN -- Recommended belonging to the G1 band may be selected by the operator, only if -- rules EGSM_RR_ALLOC_STRATEGY0, and, for the concentric cells, only in the outer zone. These restrictions do not apply to external cells.

    - for serving cell handled by a pre-MR4 BSC: There shall be no more than 31 different BCCH frequencies for the set of all cells which are target for reselection of the same serving cell if EN_2G_TO_3G_CELL_RESELECTION(MFS) Disabled and FDD_ARFCN_LIST(BSC) is not empty. -for Non Evolium serving cell handled by a BSC from MR4 onwards : There shall be no more than 31 different BCCH frequencies for the set of all cells which are target for reselection of that same serving cell if EN_2G_TO_3G_CELL_RESELECTION Disabled and FDD_ARFCN_LIST(BSC) is not empty. - For Evolium serving cell handled by a BSC from MR4 onwards : There shall be no more than 32 different BCCH frequencies for the set of all target cells.

    Def value None Coded Def External -- comment Internal - The ARFCN of the G1 band are in the range {975, 976, , 1023, 0}. comment - The BCCH frequency of an adjacent external cell is directly editable in the HMI. To be consistent with the MFS related parameter, the OMC-R access is defined according to this case (changeable). The BCCH frequency of an adjacent internal cell is virtual changeable. - This parameter is not a new B9 parameter, it was already existing in the SW of previous release and has been introduced in the BTP in B9 for re-alignment (so not in CDE table)

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 32

  • Logical name BF_HI_RX HMI name BF_HI_RX B8 Yes B9 Yes TRX nb No Definition Threshold on LAPD RX buffers occupancy for transition from normal to busy condition. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Network (CDE) reference domain y Spec LapD Management OMC-R None (DLS) Type Threshold Unit % reference access Coding rules -- Min value 0 Coded 0 Mandatory -- Max 100 Coded 100 rulesRecommended BF_HI_RX > BF_LO_RX Coded Def 80 Recommended BF_HI_RX > BF_LO_RX Def value 80 Coded Def 80 rules External -- comment Internal -- comment

    Logical name BF_HI_TX HMI name BF_HI_TX B8 Yes B9 Yes TRX nb No Definition Threshold on LAPD TX buffers occupancy for transition from normal to busy condition. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Network (CDE) reference domain y Spec LapD Management OMC-R None (DLS) Type Threshold Unit None reference access Coding rules -- Min value 0 Coded 0 Mandatory -- Max 30 Coded 30 rulesRecommended BF_HI_TX > BF_LO_TX Coded Def 16 Recommended BF_HI_TX > BF_LO_TX Def value 16 Coded Def 16 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 33

  • Logical name BF_LO_RX HMI name BF_LO_RX B8 Yes B9 Yes TRX nb No Definition Threshold on LAPD RX buffers occupancy for transition from busy to normal condition. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Network (CDE) reference domain y Spec LapD Management OMC-R None (DLS) Type Threshold Unit % reference access Coding rules -- Min value 0 Coded 0 Mandatory -- Max 100 Coded 100 rulesRecommended BF_LO_RX < BF_HI_RX Coded Def 70 Recommended BF_LO_RX < BF_HI_RX Def value 70 Coded Def 70 rules External -- comment Internal -- comment

    Logical name BF_LO_TX HMI name BF_LO_TX B8 Yes B9 Yes TRX nb No Definition Threshold on LAPD TX buffers occupancy for transition from busy to normal condition. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Network (CDE) reference domain y Spec LapD Management OMC-R None (DLS) Type Threshold Unit None reference access Coding rules -- Min value 0 Coded 0 Mandatory -- Max 30 Coded 30 rulesRecommended BF_LO_TX < BF_HI_TX Coded Def 8 Recommended BF_LO_TX < BF_HI_TX Def value 8 Coded Def 8 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 34

  • Logical name BS_AG_BLKS_RES (BSC) HMI name BS_AG_BLKS_RES B8 Yes B9 Yes TRX nb No Definition Number of CCCH blocks reserved for the access grant channel (AGCH). Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 05.02 Application GSM Categor Site (CAE) reference domain y Spec Paging & access grant control OMC-R Changeable Type Number Unit None reference access Coding rules coded on 3 bits (000 : 0, ...111 : 7) Min value 0 Coded 0 Mandatory -BS_AG_BLKS_RES (MFS) = BS_AG_BLKS_RES (BSC) for a given cell Max 7 Coded 7 rulesRecommended -when CCCH_CONF=0 and CBCH is configured in the cell, BS_AG_BLKS_RES>0 -- Recommended -When EN_VGCS is disabled : -- rules . if BCCH_EXT = true, then BS_AG_BLKS_RES >= 1 -When EN_VGCS is enabled : . If BCCH_EXT = false , then BS_AG_BLKS_RES >= NUMBER_NCH_BLOCKS . if BCCH_EXT = true, then BS_AG_BLKS_RES > NUMBER_NCH_BLOCKS Def value 4 Coded Def 4 External Maximum and Default values given for CCCH_CONF=0 comment For CCCH_CONF=1, max=2, def=1 Internal At OMC, CBCH configured in the cell corresponds to channelCombination = CBH or SDH in the TRX attribute listOfRadioChannel. comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 35

  • Logical name BS_CV_MAX (BSC) HMI name BS_CV_MAX B8 Yes B9 Yes TRX nb No Definition Number of remaining RLC data blocks sent (per assigned PDCH) by the MS, below which the Cell Type No Count Down procedure is entered. Sub-syste BSC RMS No One third of the number of RLC data blocks per assigned PDCH before the MS checks if the resolution contention has failed. Instance cell Rec 3GPP TS 04.60 Application GPRS Categor Site (CAE) reference domain y Spec System information management OMC-R Changeable Type Number Unit None reference access Coding rules Coded on 4 bits (1==0001, 2 == 0010 .. 15 == 1111). Min value 1 Coded 1 Mandatory Equal to BS_CV_MAX (MFS) Max 15 Coded 15 rulesRecommended BS_CV_MAX should be set to a value equal to the "minimum" round trip delay to optimise Coded Def 9 Recommended BS_CV_MAX should be set to a value equal to the "minimum" round trip delay to optimise Def value 9 Coded Def 9 rules the uplink re-transmission of non-acknowledged blocks and minimise window-stalled situations. If BS_CV_MAX is set greater than round-trip-delay, uplink retransmissions of unacknowledged blocks may be delayed. It is recommended to set this parameter as follows depending whether or not GPRS traffic is carried through Abis or Ater satellite links: - BS_CV_MAX = 9 if GPRS traffic is carried through Abis and Ater terrestrial links in the serving cell, - BS_CV_MAX = 15 if GPRS traffic is carried either through Abis satellite links or Ater External Used by the MS to start the countdown value process (release of UL TBF) or to consider acknowledgement messages as valid for a given comment RLC data block. Lower values avoid too many TBF releases and reestablishments. Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 36

  • Logical name BS_P_CON_ACK HMI name BS_P_CON_ACK B8 Yes B9 Yes TRX nb No Definition Supervision of the BS Power Control procedure. Cell Type Yes Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Power control & radio link supervision OMC-R Changeable Type Timer Unit 2 x Samfr reference access Coding rules step size=1 (2 x Samfr) Min value 0 Coded 0 Mandatory -- Max 31 Coded 31 rulesRecommended -- Coded Def 3 Recommended -- Def value 3 Coded Def 3 rules External -- comment Internal CT: Depends on Cell Type and BTS Type comment

    Logical name BS_P_CON_INT HMI name BS_P_CON_INT B8 Yes B9 Yes TRX nb No Definition Minimum delay between two consecutive BS power commands. Cell Type Yes Sub-syste BSC RMS No Instance cell Rec GSM TS 05.08 Application GSM Categor Site (CAE) reference domain y Spec Power control & radio link supervision OMC-R Changeable Type Timer Unit 2 x Samfr reference access Coding rules step size=1 (2 x Samfr) Min value 0 Coded 0 Mandatory -- Max 31 Coded 31 rulesRecommended -- Coded Def 1 Recommended -- Def value 1 Coded Def 1 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 37

  • Logical name BS_PA_MFRMS (BSC) HMI name BS_PA_MFRMS B8 Yes B9 Yes TRX nb No Definition Number of 51 frame multiframes between consecutive occurrences of a Paging Group. Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 05.02 Application GSM Categor Site (CAE) reference domain y Spec Paging & access grant control OMC-R Changeable Type Number Unit None reference access Coding rules coded on 3 bits (000 : 2, ... 111: 9) Min value 2 Coded 0 Mandatory BS_PA_MFRMS (BSC) = BS_PA_MFRMS (MFS) for a given cell Max 9 Coded 7 rulesRecommended -- Coded Def 3 Recommended -- Def value 5 Coded Def 3 rules External The bigger this parameter is, the lesser the MS power consumption is. comment Internal -- comment

    Logical name BS_TXPWR_MAX (BSC) HMI name BS_TXPWR_MAX B8 Yes B9 Yes TRX nb No Definition This parameter defines the power reduction relative to the maximum GMSK output power of Cell Type No the BTS. Sub-syste BSC RMS No Instance cell Rec 3GPP TS 05.08 Application GSM Categor Site (CAE) reference domain y Spec Power control & radio link supervision OMC-R Changeable Type Number Unit dB reference access Coding rules step size = 2dB. 0: 0 dB, 1: -2dB, ..., 15: -30dB Min value -30 Coded 15 Mandatory BS_TXPWR_MAX >= BS_TXPWR_MIN Max 0 Coded 0 rulesRecommended Equal to BS_TXPWR_MAX (MFS) -- Coded Def 0 rules Def value 0 Coded Def 0 External The BTS maximum allowed transmit power is defined relatively to the BTS maximum RF transmit power in GMSK (due to hardware comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 38

  • Logical name BS_TXPWR_MAX_INNER (BSC) HMI name BS_TXPWR_MAX_INNER B8 Yes B9 Yes TRX nb No Definition This parameter defines the power reduction relative to the maximum GMSK output power of Cell Type Yes the TRX of the inner zone in a concentric or multi-band cell. Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Power control & radio link supervision OMC-R Changeable Type Number Unit dB reference access Coding rules step size = 2dB. 0: 0 dB, 1: -2dB, ..., 15: -30dB Min value -30 Coded 15 Mandatory Equal to BS_TXPWR_MAX_INNER (MFS) and BS_TXPWR_MAX_INNER >= BS_TXPWR_MIN Max 0 Coded 0 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External The BTS maximum allowed transmit power is defined relatively to the BTS maximum RF transmit power in GMSK (due to hardware comment limitation).

    Internal Meaningful only in cells where: CELL_PARTITION_TYPE = concentric. comment

    Logical name BS_TXPWR_MIN HMI name BS_TXPWR_MIN B8 Yes B9 Yes TRX nb No Definition BTS minimum allowed transmission power. Cell Type No Sub-syste BSC RMS No Instance cell Rec 3GPP TS 05.08 Application GSM Categor Site (CAE) reference domain y Spec Power control & radio link supervision OMC-R Changeable Type Number Unit dB reference access Coding rules step size = 2dB. 0: 0 dB, 1: -2dB, ..., 15: -30dB Min value -30 Coded 15 Mandatory BS_TXPWR_MIN = BS_TXPWR_MIN -- Coded Def 12 rules Def value -24 Coded Def 12 External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 39

  • Logical name BSC_EN_RF_RES_IND HMI name BSC_EN_RF_RES_IND B8 Yes B9 Yes TRX nb No Definition Enables/disables the RF RESOURCE INDICATION processing by the BSC. Cell Type No Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Resource allocation & management OMC-R None (DLS) Type Flag Unit None reference access Coding rules 0: disabled, 1: enabled Min value 0 Coded 0 Mandatory -- Max 1 Coded 1 rulesRecommended -- Coded Def 1 Recommended -- Def value 1 Coded Def 1 rules External -- comment Internal -- comment

    Logical name BSC_X25_primary_address_i [1] HMI name BSC Primary X25 Address [1] B8 Yes B9 Yes TRX nb No Definition First character of BSC X25 primary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 40

  • Logical name BSC_X25_primary_address_i [10] HMI name BSC Primary X25 Address [10] B8 Yes B9 Yes TRX nb No Definition Tenth character of BSC X25 primary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory -- Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Logical name BSC_X25_primary_address_i [11] HMI name BSC Primary X25 Address [11] B8 Yes B9 Yes TRX nb No Definition Eleventh character of BSC X25 primary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 41

  • Logical name BSC_X25_primary_address_i [12] HMI name BSC Primary X25 Address [12] B8 Yes B9 Yes TRX nb No Definition Twelfth character of BSC X25 primary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Logical name BSC_X25_primary_address_i [13] HMI name BSC Primary X25 Address [13] B8 Yes B9 Yes TRX nb No Definition Thirteenth character of BSC X25 primary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 42

  • Logical name BSC_X25_primary_address_i [14] HMI name BSC Primary X25 Address [14] B8 Yes B9 Yes TRX nb No Definition Fourteenth character of BSC X25 primary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Logical name BSC_X25_primary_address_i [15] HMI name BSC Primary X25 Address [15] B8 Yes B9 Yes TRX nb No Definition Fifteenth character of BSC X25 primary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 43

  • Logical name BSC_X25_primary_address_i [2] HMI name BSC Primary X25 Address [2] B8 Yes B9 Yes TRX nb No Definition Second character of BSC X25 primary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Logical name BSC_X25_primary_address_i [3] HMI name BSC Primary X25 Address [3] B8 Yes B9 Yes TRX nb No Definition Third character of BSC X25 primary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 44

  • Logical name BSC_X25_primary_address_i [4] HMI name BSC Primary X25 Address [4] B8 Yes B9 Yes TRX nb No Definition Fourth character of BSC X25 primary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Logical name BSC_X25_primary_address_i [5] HMI name BSC Primary X25 Address [5] B8 Yes B9 Yes TRX nb No Definition Fifth character of BSC X25 primary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 45

  • Logical name BSC_X25_primary_address_i [6] HMI name BSC Primary X25 Address [6] B8 Yes B9 Yes TRX nb No Definition Sixth character of BSC X25 primary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Logical name BSC_X25_primary_address_i [7] HMI name BSC Primary X25 Address [7] B8 Yes B9 Yes TRX nb No Definition Seventh character of BSC X25 primary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 46

  • Logical name BSC_X25_primary_address_i [8] HMI name BSC Primary X25 Address [8] B8 Yes B9 Yes TRX nb No Definition Eighth character of BSC X25 primary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Logical name BSC_X25_primary_address_i [9] HMI name BSC Primary X25 Address [9] B8 Yes B9 Yes TRX nb No Definition Ninth character of BSC X25 primary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 47

  • Logical name BSC_X25_secondary_address_i [1] HMI name BSC Secondary X25 Address [1] B8 Yes B9 Yes TRX nb No Definition First character of BSC X25 secondary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory -- Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Logical name BSC_X25_secondary_address_i HMI name BSC Secondary X25 Address [10] B8 Yes B9 Yes TRX nb No Definition Tenth character of BSC X25 secondary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory -- Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 48

  • Logical name BSC_X25_secondary_address_i HMI name BSC Secondary X25 Address [11] B8 Yes B9 Yes TRX nb No Definition Eleventh character of BSC X25 secondary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory -- Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Logical name BSC_X25_secondary_address_i HMI name BSC Secondary X25 Address [12] B8 Yes B9 Yes TRX nb No Definition Twelfth character of BSC X25 secondary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 49

  • Logical name BSC_X25_secondary_address_i HMI name BSC Secondary X25 Address [13] B8 Yes B9 Yes TRX nb No Definition Thirteenth character of BSC X25 secondary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Logical name BSC_X25_secondary_address_i HMI name BSC Secondary X25 Address [14] B8 Yes B9 Yes TRX nb No Definition Fourteenth character of BSC X25 secondary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 50

  • Logical name BSC_X25_secondary_address_i HMI name BSC Secondary X25 Address [15] B8 Yes B9 Yes TRX nb No Definition Fifteenth character of BSC X25 secondary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Logical name BSC_X25_secondary_address_i [2] HMI name BSC Secondary X25 Address [2] B8 Yes B9 Yes TRX nb No Definition Second character of BSC X25 secondary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 51

  • Logical name BSC_X25_secondary_address_i [3] HMI name BSC Secondary X25 Address [3] B8 Yes B9 Yes TRX nb No Definition Third character of BSC X25 secondary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Logical name BSC_X25_secondary_address_i [4] HMI name BSC Secondary X25 Address [4] B8 Yes B9 Yes TRX nb No Definition Fourth character of BSC X25 secondary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 52

  • Logical name BSC_X25_secondary_address_i [5] HMI name BSC Secondary X25 Address [5] B8 Yes B9 Yes TRX nb No Definition Fifth character of BSC X25 secondary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Logical name BSC_X25_secondary_address_i [6] HMI name BSC Secondary X25 Address [6] B8 Yes B9 Yes TRX nb No Definition Sixth character of BSC X25 secondary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 53

  • Logical name BSC_X25_secondary_address_i [7] HMI name BSC Secondary X25 Address [7] B8 Yes B9 Yes TRX nb No Definition Seventh character of BSC X25 secondary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Logical name BSC_X25_secondary_address_i [8] HMI name BSC Secondary X25 Address [8] B8 Yes B9 Yes TRX nb No Definition Eighth character of BSC X25 secondary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 54

  • Logical name BSC_X25_secondary_address_i [9] HMI name BSC Secondary X25 Address [9] B8 Yes B9 Yes TRX nb No Definition Ninth character of BSC X25 secondary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 1character of a string. default = blank character Min value 0 Coded 0 Mandatory changeable if SMSCB_STATE=disabled Max 255 Coded 255 rulesRecommended -- Coded Def 20 Recommended -- Def value 20 Coded Def 20 rules External The minimum, maximum and default values indicated are only for implementation purposes. comment Internal -- comment

    Logical name BSIC (GSM) HMI name BSIC B8 Yes B9 Yes TRX nb No Definition Concatenation of the NCC and the BCC. Cell Type No Sub-syste BSC RMS No Instance cell Rec GSM TS 04.08 Application GSM Categor Site (CAE) reference domain y Spec Radio measurements data processing OMC-R Changeable Type Abstract Unit None reference access Coding rules -- Min value # Coded Mandatory -- Max # Coded rulesRecommended -- Coded Def Recommended -- Def value # Coded Def rules External -- comment Internal See BCC (BSC) and NCC (BSC) comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 55

  • Logical name BSS_CIPH_LIST (Priority 1) HMI name Ciphering Algorithms Priority 1 B8 Yes B9 Yes TRX nb No Definition List of encryption algorithms in their prioritized order. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Ciphering procedure OMC-R Changeable Type List of numbers Unit None reference access Coding rules coded as an array of 7 bytes. Each byte contains a reference to an encryption algorithm: 1 for Min value 1 Coded 1 A5/1, ... 7 for A5/7. Mandatory The same encryption algorithm reference cannot be used for two different priorities Max 2 Coded 2 rulesRecommended -- Coded Def 1 Recommended -- Def value 1 Coded Def 1 rules External -- comment Internal Only A5/1 and A5/2 algorithms are supported in this release. Only Priority 1 and Priority 2 fields are modifiable and displayed at the OMC-R. comment

    Logical name BSS_CIPH_LIST (Priority 2) HMI name Ciphering Algorithms Priority 2 B8 Yes B9 Yes TRX nb No Definition List of encryption algorithms in their prioritized order. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Ciphering procedure OMC-R Changeable Type List of numbers Unit None reference access Coding rules coded as an array of 7 bytes. Each byte contains a reference to an encryption algorithm: 1 for Min value 1 Coded 1 A5/1, ... 7 for A5/7. Mandatory The same encryption algorithm reference cannot be used for two different priorities Max 2 Coded 2 rulesRecommended -- Coded Def 2 Recommended -- Def value 2 Coded Def 2 rules External -- comment Internal Only A5/1 and A5/2 algorithms are supported in this release. Only Priority 1 and Priority 2 fields are modifiable and displayed at the OMC-R. comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 56

  • Logical name BSS_CIPH_LIST (Priority 3) HMI name Ciphering Algorithms Priority 3 B8 Yes B9 Yes TRX nb No Definition List of encryption algorithms in their prioritized order. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Not Used (NU) reference domain y Spec Ciphering procedure OMC-R None (DLS) Type List of numbers Unit None reference access Coding rules coded as an array of 7 bytes. Each byte contains a reference to an encryption algorithm: 1 for Min value 1 Coded 1 A5/1, ... 7 for A5/7. Mandatory The same encryption algorithm reference cannot be used for two different priorities Max 7 Coded 7 rulesRecommended -- Coded Def 3 Recommended -- Def value 3 Coded Def 3 rules External -- comment Internal Only A5/1 and A5/2 algorithms are supported in this release. Only Priority 1 and Priority 2 fields are modifiable and displayed at the OMC-R. comment

    Logical name BSS_CIPH_LIST (Priority 4) HMI name Ciphering Algorithms Priority 4 B8 Yes B9 Yes TRX nb No Definition List of encryption algorithms in their prioritized order. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Not Used (NU) reference domain y Spec Ciphering procedure OMC-R None (DLS) Type List of numbers Unit None reference access Coding rules coded as an array of 7 bytes. Each byte contains a reference to an encryption algorithm: 1 for Min value 1 Coded 1 A5/1, ... 7 for A5/7. Mandatory The same encryption algorithm reference cannot be used for two different priorities Max 7 Coded 7 rulesRecommended -- Coded Def 4 Recommended -- Def value 4 Coded Def 4 rules External -- comment Internal Only A5/1 and A5/2 algorithms are supported in this release. Only Priority 1 and Priority 2 fields are modifiable and displayed at the OMC-R. comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 57

  • Logical name BSS_CIPH_LIST (Priority 5) HMI name Ciphering Algorithms Priority 5 B8 Yes B9 Yes TRX nb No Definition List of encryption algorithms in their prioritized order. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Not Used (NU) reference domain y Spec Ciphering procedure OMC-R None (DLS) Type List of numbers Unit None reference access Coding rules coded as an array of 7 bytes. Each byte contains a reference to an encryption algorithm: 1 for Min value 1 Coded 1 A5/1, ... 7 for A5/7. Mandatory The same encryption algorithm reference cannot be used for two different priorities Max 7 Coded 7 rulesRecommended -- Coded Def 5 Recommended -- Def value 5 Coded Def 5 rules External -- comment Internal Only A5/1 and A5/2 algorithms are supported in this release. Only Priority 1 and Priority 2 fields are modifiable and displayed at the OMC-R. comment

    Logical name BSS_CIPH_LIST (Priority 6) HMI name Ciphering Algorithms Priority 6 B8 Yes B9 Yes TRX nb No Definition List of encryption algorithms in their prioritized order. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Not Used (NU) reference domain y Spec Ciphering procedure OMC-R None (DLS) Type List of numbers Unit None reference access Coding rules coded as an array of 7 bytes. Each byte contains a reference to an encryption algorithm: 1 for Min value 1 Coded 1 A5/1, ... 7 for A5/7. Mandatory The same encryption algorithm reference cannot be used for two different priorities Max 7 Coded 7 rulesRecommended -- Coded Def 6 Recommended -- Def value 6 Coded Def 6 rules External -- comment Internal Only A5/1 and A5/2 algorithms are supported in this release. Only Priority 1 and Priority 2 fields are modifiable and displayed at the OMC-R. comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 58

  • Logical name BSS_CIPH_LIST (Priority 7) HMI name Ciphering Algorithms Priority 7 B8 Yes B9 Yes TRX nb No Definition List of encryption algorithms in their prioritized order. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Not Used (NU) reference domain y Spec Ciphering procedure OMC-R None (DLS) Type List of numbers Unit None reference access Coding rules coded as an array of 7 bytes. Each byte contains a reference to an encryption algorithm: 1 for Min value 1 Coded 1 A5/1, ... 7 for A5/7. Mandatory The same encryption algorithm reference cannot be used for two different priorities Max 7 Coded 7 rulesRecommended -- Coded Def 7 Recommended -- Def value 7 Coded Def 7 rules External -- comment Internal Only A5/1 and A5/2 algorithms are supported in this release. Only Priority 1 and Priority 2 fields are modifiable and displayed at the OMC-R. comment

    Logical name BSS_SEND_CM_ENQUIRY HMI name Send_CM_Enquiry B8 Yes B9 Yes TRX nb No Definition Controls the trigger of Classmark Enquiry procedure at call establishment time. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Classmark handling OMC-R Changeable Type Flag Unit None reference access Coding rules 0: the classmark enquiry is never initiated by the BSC; Min value 0 Coded 0 1: on reception of a LOCATION UPDATING REQUEST message with ES IND flag set to 0, the BSC will always initiate a classmark enquiry; 2: on reception of a LOCATION UPDATING REQUEST message with ES IND flag set to 0, the BSC will initiate the classmark enquiry if algorithm A5/1 is not available (information available in MS classmark 1 IE sent in the LOCATION UPDATING REQUEST). Mandatory -- Max 2 Coded 2 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 59

  • Logical name BTS_CIPH_CAP HMI name ciphering capabilities B8 Yes B9 Yes TRX nb No Definition List of flags indicating what are the BTS ciphering capabilities. Cell Type No Sub-syste BSC RMS No Instance BTS Rec None Application GSM Categor Site (CAE) reference domain y Spec Ciphering procedure OMC-R Displayed Type Flag Unit None reference access Coding rules Coded as a 8 bits bitmap. Each bit indicates if corresponding encryption algorithm is Min value 0 Coded 0 supported. bit 1 (LSB) : no encryption. bit 2 : A5/1. bit 3 : A5/2...bit 8 : A5/7. bit x =0: encryption not Mandatory -- Max 255 Coded 255 rulesRecommended -- Coded Def 1 Recommended -- Def value 1 Coded Def 1 rules External Default value depends on configuration. The value indicated here is for implementation purposes. comment Internal Bit 1 = 1 (mandatory)Bit 4 to 8 = 0 (mandatory)Bits 1 and 4 to 8 shall not be displayed at the OMC-R.Transmitted to the BTS in the comment BTS_CONF_DATA message

    Logical name BTS_Q_LENGTH HMI name BTS_Queue_Length B8 Yes B9 Yes TRX nb Yes Definition Maximum number of Assignment Requests and Handover Requests that can be queued Cell Type No simultaneously. Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Resource allocation & management OMC-R Changeable Type Number Unit None reference access Coding rules -- Min value 0 Coded 0 Mandatory -- Max 64 Coded 64 rulesRecommended -- Coded Def 3 Recommended -- Def value 3 Coded Def 3 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 60

  • Logical name Call_user_data_sel HMI name Call_User_Data_Selector B8 Yes B9 Yes TRX nb No Definition Identifies the higher protocol selector for an outgoing connection. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Reference Unit None reference access Coding rules 0 to 16 bytes string Min value 0 Coded 0 Mandatory Can be changed only when SMSCB_State is disabled Max 255 Coded 255 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External Default value depends on configuration. The value indicated here is for implementation purposes. comment Each byte of the string can get a value in the range [0..255]. Internal OMC sends a string of a fixed length of 16bytes. comment The default string is an empty string. The right side of the string might be filled by zeros until 16 bytes are reached.

    Logical name CAPTURE_TRAFFIC_CONDITION HMI name CAPTURE_TRAFFIC_CONDITIO B8 Yes B9 Yes TRX nb No Definition This parameter determines the condition on traffic load in the serving cell to trigger a general N Cell Type No capture handover. Sub-syste BSC RMS No Instance cell Rec None Application GSM Categor Site (CAE) reference domain y Spec Handover preparation OMC-R Changeable Type Flag Unit None reference access Coding rules 0: Any load, 1: Not low, 2: High Min value 0 Coded 0 Mandatory -- Max 2 Coded 2 rulesRecommended -- Coded Def 0 Recommended -- Def value 0 Coded Def 0 rules External -- comment Internal -- comment

    Edition 20 Released BSS Telecom parameters 3BK 11203 0103 DSZZA Page 61

  • Logical name CBC_window HMI name CBC_Window B8 Yes B9 Yes TRX nb No Definition Maximum number of outstanding primitives on the BSC/CBC interface for both incoming and Cell Type No outgoing primitives. Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE) reference domain y Spec Short message service cell broadcast OMC-R Changeable Type Number Unit None reference access Coding rules -- Min value 1 Coded 1 Mandatory Can be changed only when SMSCB_State is disabled Max 3 Coded 3 rulesRecommended shall be set to "1" when SMSCB_FEATURE_SET="FS1" -- Coded Def 1 rules Def value 1 Coded Def 1 External Default value corresponds to SMSCB_FEATURE_SET = FS1. comment If SMSCB_FEATURE_SET = FS2, CBC_Window should be set to 3. Internal -- comment

    Logical name CBC_X25_primary_address HMI name CBC Primary X25 Address B8 Yes B9 Yes TRX nb No Definition CBC X25 primary address. Cell Type No Sub-syste BSC RMS No Instance BSC Rec None Application GSM Categor Site (CAE