8/12/2019 Optimizer Introduction Setup
1/30
1 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Optimizer Introduction
8/12/2019 Optimizer Introduction Setup
2/30
2 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Contents
Optimizer Overview
Optimizer Interfaces
Optimisation workflow in NetAct
8/12/2019 Optimizer Introduction Setup
3/30
Configuring
ServiceManagement
Security & SystemManagement
Planning
SubscriptionManagement
Reporting
Adaptation
Multitechnology & MultivendorNetworks
Multiservice,
OptimisingMonitoring
NokiaNetAct
Functionality areas of NetAct
Functionality area
8/12/2019 Optimizer Introduction Setup
4/30
4 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Optimizer target is to provide GSM/GPRS/WCDMA functionality for maximising NW capacity utilisation rate
optimising the service performance with minimum manual effortThe application combines means for NW analysis and optimisation:
Geographical NW visualisation and analysisActual and planned configuration on a map Performance measurements with elements from GSM and WCDMA
networks Manual optimisation
GIS based adjacency management Browser based parameter management Synchronised with CM Editor
Automated optimisation Seamless integration with
optimisation solutions
Optimizer Features
NW wide optimisation
Map data
Cell cov erages
Graphical map
KPI dataConfiguration
data
Rules
Consistency checks
CellParameters
8/12/2019 Optimizer Introduction Setup
5/305 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Optimizer Interfaces
Interfaces overview
Interfaces with RAC
Interfaces with Reporter
Preliminary tasks
8/12/2019 Optimizer Introduction Setup
6/306 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Optimizer - Interfaces and Data Flow
Optimizer
PM Data
CM Data
SITE and ANTE
RACUpload ACTUALsProvision Plans
xml
Q.3
Planner
ReporterAdministration of
Measurements, e.g.
Channel FinderDefined Adjacencies
OSS Database
OptimizerDatabase
8/12/2019 Optimizer Introduction Setup
7/307 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Network Data and Non-Network Data
Optimizer
PM Data
RAC DatabaseCM Data
SITE and ANTE
OSS Database
OptimizerDatabase
RAC Database
Non-network Data
e.g. Antenna data(bearing, tilt, height)
Network Data
Reporter Database
Antenna data:
Radiation patternImport
8/12/2019 Optimizer Introduction Setup
8/308 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Interworking with RAC and Reporter
Optimizer obtains the actual or planned GSM configuration datafrom Radio Access Developer part of RAC
Actual: e.g. frequency allocation Planned: e.g. adjacencies for new BTSs
Performance statistics are retrieved from Reporter
Internal access to PM database
Selected set of KPIs for optimisation needs
The same KPIs as in Reporter
Optimizer combines the selected CM & PM information together with optimisation specific data
User input for guiding the algorithms
optimisation targets
User specific map and browser view customisation
optimisation results are stored as plans in RAC DB Common RAC functionality for plan management and provisioning
Further plan processing in CM Editor, CM Analyser and CMProvisioner
8/12/2019 Optimizer Introduction Setup
9/309 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
CM Data
BSC
RNC
CM Plan Manager
CM Editor
CM Analyser
CM Provisioner
Upload ManagedObjects
Topology
Browser
Optimizer
Adminstrationof Measurements
PM Data
RAC
Reporter
Interworking with RAC and Reporter
BSC
8/12/2019 Optimizer Introduction Setup
10/30
10 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Actual configuration data is presented in Navigator each time when Optimizer isopened
Regularly synchronised with RAC database Object parameters identical in Optimizer and CM Editor
GSM network objects
BSC
BCF
BTS, ADCE, TRX, ANTE Site
HOC
POC
RAN objects RNC
WBTS WCell ADJW, ADJG, ADJS, ADJI Site
Configuration data for Optimizer 1.1
8/12/2019 Optimizer Introduction Setup
11/30
11 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
KPIs from PM database
Reporter collects the data from network and stores the counters
Dedicated KPIs provided in Reporter for different purposesOptimizer Report defined containing KPIs needed for optimisation
KPIs are calculated based on scripts defined in Report Builder
Selected KPIs from yesterday and last week are copied automatically toOptimizer database over night
Fixed set of GSM, GPRS and WCMDA RAN KPIsCommon KPI formula in all Reports and Optimizer keeps the
consistency
Interference measurement data as an exception
CF and DAC measurements are activated in BSC only when needed
Results are retrieved from PM database to Optimizer by request via aseparate interface (IM creation)
Possible to provide the data also from an external tool (IM import)
8/12/2019 Optimizer Introduction Setup
12/30
12 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Why Mobile Measurement Based OptimisationFeatures?
In most of the planning tools the radio environment (interference
matrix etc) is estimated with predictions Predictions can be made quiteaccurate if all models are very
accurate and tuned
Propagation model, map data, antenna model
Optimizer uses predictions mainly for visualisation andanalysis. The decisions are made based on measurements
However the best accuracy and the best coverage of themeasurements can be done with Mobile Measurements
Coverage: the interference data is reported where the
mobiles really are
Standard MMRs (Mobile Measurement Reports) are used
8/12/2019 Optimizer Introduction Setup
13/30
13 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Preliminary tasks
8/12/2019 Optimizer Introduction Setup
14/30
14 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Contents
Check the Network Configuration Data
Create Parameter Templates
Managing Measurement Data
O ti i i N t k U i O ti i
8/12/2019 Optimizer Introduction Setup
15/30
15 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Optimising a Network Using OptimizerOverview of the preliminary tasks
Start
Check the network configuration dataCM Editor
Create parameter templatesCM Editor
EndManaging Measurement DataOptimizer
8/12/2019 Optimizer Introduction Setup
16/30
16 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Checking the network configurationdata
Importing Site and Antenna data
Check co-ordinate settings of SITE objects
Check the settings for the ANTE objects
8/12/2019 Optimizer Introduction Setup
17/30
17 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Import SITE and ANTE objects
Site import(using Plan Manager)
Antenna import(using Plan Manager)
Merge non NW data(using Plan Manager)
SITE XML file Antenna XML file
Coordinates
LogitudeLatitude
AntennaBearing
TiltHeight
Import Type:SITE information
Import Type:Plans
Note: The radiation patterns need to beimported separately to Optimizer from theplanning tool.
Checking the ANTE objects in CM
8/12/2019 Optimizer Introduction Setup
18/30
21 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Checking the ANTE-objects in CMEditor
8/12/2019 Optimizer Introduction Setup
19/30
23 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Checking the SITE-objects in CM Editor
8/12/2019 Optimizer Introduction Setup
20/30
24 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Checking ANTE-objects in Optimizer
8/12/2019 Optimizer Introduction Setup
21/30
25 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Creating parameter templates fornew adjacencies
Template Management in CM Editor
Create a new template in CM Editor
Assign different templates to managed objects in CM Editor
8/12/2019 Optimizer Introduction Setup
22/30
26 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Template Management in CM Editor
8/12/2019 Optimizer Introduction Setup
23/30
30 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Managing measurement data
Process of preparing and activating measurements
Concepts and purpose of BA list
Configuring a BA list using MML and CM Editor
Required measurements in BSC for frequency plan creation
Checking the prerequisites in BSC for starting themeasurements
Starting measurements with Administration of Measurements
Preparation & Measurements activation
8/12/2019 Optimizer Introduction Setup
24/30
31 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Preparation & Measurements activation
Benchmark the NW for comparison(KPIs)
Obtain BCCH allocation listsinformation from the NW area to be
optimized
Create new BA Lists
Activate CF and DAC measurementsand ensure that traffic and HO
measurements are running
Schedule provisioning theconfiguration Plans to RNW
START
Create configuration Plans to attach
and activate BA lists to BSCs
Retrieve Measurement reports andgenerate Interference Matrix
CM
Editor
CMProvisioner
Administration ofmeasurements
Optimizer1.1
Covered in chapterCreating frequency
Plan with Optimizer
C t d f BA Li t
8/12/2019 Optimizer Introduction Setup
25/30
32 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Concept and purpose of BA List
Obtain the exiting BA-list (e.g. using Network Doctor) to
investigate how the adjacencies are defined for each serving cell.*)The existing BA lists contain only the BCCHs of the definedadjacency cells.The reason for creating new BCCH Allocation lists is to retrievealso measurement data from surrounding cells which are notdefined as adjacency cells.These new defined BA lists are used only during the Measuringperiod and should be removed after the measurements arecompleted.A new BA list can be created using MML or CM Editor (plan
based).
*)Note: This is only important if the total amount of used BCCHsin the NW to be optimized exceeds 32. If less than 32 BCCHsare used then there is no need for this process step
Measurements for NetAct Optimizer
8/12/2019 Optimizer Introduction Setup
26/30
43 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
ADJACENCY OPTIMIZATION
HO PERFORMANCE
TRAFFIC
DEFINED ACJACENCY CELL MEASUREMENTS *
CHANNEL FINDER MEASUREMENTS *
INTERFERENCE MATRIX GENERATIONDEFINED ACJACENCY CELL MEASUREMENTS *
CHANNEL FINDER MEASUREMENTS *
* DAC and CF measurements have to be explicit activated duringthe optimization process
Measurements for NetAct Optimizer
Undefined and Defined Adjacent Cell
8/12/2019 Optimizer Introduction Setup
27/30
44 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
BSC
X
B (f11, f25, f31)C (f7, f15)D (f1, f5, f12)
E (f9, f15, f6)
G (f3, f29, f8, f25)
H ( f22, f28, f2) A (f24, f33)
defined
defined
defined
defineddefined
BCCH
Un-defined
Un-definedReporter
MSs scan the whole BCCH block
Cell identifiers are BCC, NCC, BCCH
Reports collected to BSCData analysis and thresholds provide adjacent cell rankings for each measuredcell
Undefined and Defined Adjacent CellMeasurement
Adjacency Creation/Deletion
8/12/2019 Optimizer Introduction Setup
28/30
45 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Adjacency Creation/DeletionMeasurements
BSC
BTS BAL BAL BAL
BAL = All BCCH
BCCH of undefinedcells
...and definedadjacent cells
Active MS
In additiontoDefined/Undefined AdjacentCell MeasurementsAdjacency Creation andDeletion uses:
1. Handover traffic percentage2. Handover attempts to
adjacent cell
3. Handover success toadjacent cell
St t Ad i i t ti f M t
8/12/2019 Optimizer Introduction Setup
29/30
47 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Start Administration of Measurements
Preliminary Tasks Summary
8/12/2019 Optimizer Introduction Setup
30/30
54 NOKIA / Preliminary tasks in Optimizer / 6-137228 / version 2.0 en / 05.05.2004 / Bettina Baacke
Preliminary Tasks Summary
Import sites and antennas (CM Plan Manager)
or create sites and antennas (CM Editor)
Assign sites to network elements (CM Editor)
Create Cell Antenna Links GCAL and WCAL (CM Editor)
Create templates for cells and adjacencies (CM Editor)
Plan BA lists for measurements (CM Editor)
Define and activate CF and DAC measurements(Top Level UI -> Utils -> Administration of measurements)
Reset BA lists (CM Editor)