Top Banner
NDT OF CONCRETE By: Bhaskar Joshi
32

Non Destructive Testing

Nov 25, 2014

Download

Documents

BHASKAR JOSHI

Brief description about what is NDT, why it is useful and the various tests it contains.
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Non Destructive Testing

NDT OF CONCRETE

By: Bhaskar Joshi

Page 2: Non Destructive Testing

What is Non Destructive Testing ??? According to the AMERICAN Standards of

Non Destructive Testing (ASNT), NDT is said to be comprising those test methods used to examine an object, material or system without impairing its future usefulness.

As per the INDIAN Standards of Non Destructive Testing (ISNT), NDT is a way of testing without destroying. This means that the component can continue to be used and that the non destructive testing method has done no harm.

Page 3: Non Destructive Testing

Why Non Destructive Testing ?????? Manner of preparation and use is poor, mainly

due to lack of proper quality control & supervision during the course of construction.

Often safety & durability of structures are given the go-by by permitting poor quality of construction.

At present the test used mainly as a basis of quality control is compression testing of cubes & it represents the potential strength of the concrete used.

Page 4: Non Destructive Testing

Why Compression testing of cubes is inadequate ?????????? Quality of concrete -- The three “C”

phenomenon.

Deliberate Deviation ?

Not a True Representation of the structure due to presence of Steel, Voids, Cracks.

Can only be performed during the construction stage.

All of the above reasons make NDT helpful as well as very useful.

Page 5: Non Destructive Testing

Objectives of Non Destructive Testing !!!!

To establish homogeneity of concrete. Detection of cracks, voids and other

imperfections. Monitoring changes in concrete with

passage of time. To establish quality of one element w.r.t.

another. Assessment of existing structure for

rehabilitation planning.

Page 6: Non Destructive Testing

Types of Non Destructive Testing as per the ISNT !!!!

Rebound Hammer test. Ultrasonic pulse velocity test. Electrical Resistivity test. Half cell potential test. Cover meter test Carbonation depth measurement Chloride determination test Core test ( Partially non destructive )

Page 7: Non Destructive Testing

Rebound Hammer test !!!!!!!!!!!

Page 8: Non Destructive Testing

About Rebound Hammer !!!!!!!!!!!!!!! This is basically a surface hardness test &

should be used only on concrete where the surface has not carbonated as the results tend to be very high & unrealistic on a carbonated surface.

Hence it should be used for younger concrete than for older one. In case of old concrete the carbonated layer should be chipped off or grounded to expose the core concrete & then the hammer test should be conducted.

The rebound is affected if the surface is moist.

Page 9: Non Destructive Testing

Cont…………………………………….. CONDUCT ON SMOOTH AND UNIFORM

FACE AVOID ROUGH SPOTS, HONEY COMBS AVOID TROWELLED SURFACES THIN SECTIONS (< 100 mm) SHOULD BE

BACKED UP TO AVOID DEFLECTIONS TAKE ATLEAST 15 REBOUND READINGS

IN ANY ONE TEST

Page 10: Non Destructive Testing

Ultrasonic Pulse Velocity Test !!!!!!!!!!

Page 11: Non Destructive Testing

About Ultrasonic Pulse Velocity !!!!!! TYPES OF TESTING METHOD

DIRECT TRANSMISSION SEMI DIRECT TRANSMISSION SURFACE TRANSMISSION

To assessing the quality & integrity of concrete by passing ultrasound waves through the specimen / RCC member under test.

This test can also be used to determine the presence of honeycombs, voids, cracks etc. The instrument consists of a transmitter & a receiver (two probes).

Page 12: Non Destructive Testing

Cont…………………………………………. The distance between the two probes

(path length) can be physically measured. The time of travel for the wave to pass

from the transmitter to the receiver is recorded in the ultrasonic instrument.

Hence Ultrasonic Pulse Velocity = Path length / Time

This velocity in concrete can then be related to the uniformity of concrete.

Page 13: Non Destructive Testing

Cont………………………………………

Quality Pulse Velocity ( Km/sec )

Excellent > 4.6

Good 4.6 – 3.7

Fair 3.7 - 3.0

Poor 3.0-2.1

Very Poor < 2.1

Page 14: Non Destructive Testing

Electrical Resistivity Test !!!!!!!!!!!!!!!!!

Page 15: Non Destructive Testing

About Electrical Resistivity Test !!!!!!! This test is carried out to assess the quality /

uniformity of concrete at various depths. The instrument consists of a four probe

device. Electrical current is passed through the outer probes & the potential drop is measured by the inner probes.

From the current & voltage drop measurements, the resistivity of concrete can be measured.

This resistivity can be related to quality of concrete.

Page 16: Non Destructive Testing

Cont……………………………..

Electrical resistivity = 2(pi)aE/i (in kilo-ohm cm) where pi = 22 / 7 = 3.14 a = distance between probes E = potential difference between inner two probes in

mV i = current passed through outer probes in microamp The penetration of current depends upon the

distance between the probes. Various sets of readings are taken.

The electrical resistivity for a homogeneous material is constant.

Page 17: Non Destructive Testing

Cont………………………………… When the RCC members to be tested are

covered with costly finishes like marble, granite etc. This test can be used without having to remove such finishes.

Finally, the values of the resistivity are compared againstCorrosion Rate Resistivity

Low > 20 Kilo ohm cm

Low to moderate 10 – 20 Kilo ohm cm

High 5 – 10 Kilo ohm cm

Very High < 5 Kilo ohm cm

Page 18: Non Destructive Testing

Half Cell Potential Test !!!!!!!!!!!!!!!!!!!!

Page 19: Non Destructive Testing

About Half Cell Potential Test !!!!!!!!!! A Half cell is a piece of metal in a solution of its own

ions ( copper in copper sulphate). When connected to another half cell ( Silver ), a voltage is set up.

This test can give the probability of corrosion activity taking place at the point where the measurement of potentials are taken.

An electrical contact is established with the exposed steel & the half-cell is moved across the surface of concrete for measuring the potentials.

By convention, +ve end of voltmeter is connected to steel and –ve to half cell. Thus negative reading.

Page 20: Non Destructive Testing

Cont…………………………………………….

Copper/Copper sulphate

Silver / Silver chloride

Corrosion Condition

> -200 mV > -106 mV Low ( 10% chances )

-200 to -350 mV -106 to -256 mV Intermediate

< -350 mV < -256 mV High ( <90 % )

< -500 mV < -406 mV Severe Corrosion

Page 21: Non Destructive Testing

Cover Meter Test !!!!!!!!!!!!!!!!!!!!!!!!!!!!

Page 22: Non Destructive Testing

About Cover Meter !!!!!!!!!!!!!!!!!!!!!! This test is useful for the determination of

concrete cover, location of embedded rebars & estimation of size of embedded rebars.

The instrument is based on the magnetic technique & is calibrated for different purposes.

The cover thickness is important from the point of view of estimation of initiation of corrosion.

The location & estimation of bar diameter becomes useful in structures where there are no structural drawings available.

Page 23: Non Destructive Testing

Carbonation Depth Measurement !!! As concrete is exposed to air, some free water

content is lost and this pore water in replaced by air.

Air containing Carbon dioxide and other acidic gases can react with alkaline constituents of concrete, called Carbonation.

Hence, protection provided by concrete against corrosion is lost due to carbonation as moisture and oxygen can act relatively easily.

Thus water – cement ratio should never be excessive.

Page 24: Non Destructive Testing

Cont…………………………………….. Primary factor controlling the rate of

carbonation is the EXPOSURE CONDITIONS: Concrete saturated with water is effectively

free from carbonation. Concrete exposed to alternate dry and wet

atmosphere shows greatest depths of carbonation.

Concrete exposed to moist air periodically by precipitation shows intermediate depths of carbonation.

Page 25: Non Destructive Testing

Cont………………………………………… METHOD OF ASSESSMENT

DRILL INTO CONCRETE SPRAY PHENOLPHTHALEIN SOLUTION UNCARBONATED CONCRETE WILL SHOW

BRIGTH PINK STAIN CARBONATED CONCRETE WILL NOT

CHANGE COLOUR WITH THE ABOVE VISUAL INDICATION

DEPTH OF CARBONATION CAN BE EASILY MEASURED

Page 26: Non Destructive Testing

Chloride Determination Test !!!!!!!!! Apart from (or after) the carbonation of

concrete, the natural protection to steel is lost & thus the chlorine present in the atmosphere is free to attack the embedded steel.

Above a threshold value of chlorine ions along with degree of alkalinity of concrete, the rate of corrosion increases.

Hence it becomes important to estimate the chlorine ion content to comment on the corrosion of steel.

Page 27: Non Destructive Testing

Cont……………………………………….. There are two sources of chlorides: 1) either they enter the mix before casting

– cast in chlorides. Sources can be water or inadequately washed marine aggregates.

2) or after the concrete hardened – ingressed chlorides. Sources are the marine or industrial environment.

The cast in chlorides generally are chemically bound and it’s the ingressed chlorides which cause damage.

Page 28: Non Destructive Testing

Cont………………………………………… The concrete dust is to be collected by

drilling and is taken for testing. Generally the first 5 mm depth is neglected.

Depth increments of close to 25 mm are usually taken for collection of dust. Usually a minimum of 25 gm should be taken.

For accurate chloride determination, samples must be prepared for chemical analysis and analysed, using either Volhard's method or potentiometric titration.

Page 29: Non Destructive Testing

Core Test !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! This is a partially destructive test that is used to

co-relate the various other properties of the concrete viz. UPV, electrical resistivity, rebound number etc.

It is customary to take cores of 4 inch diameter for compressive strength determination.

Concrete core drilling for strength determination is again dependent upon various

factors for reliability. The conversion of concrete core (typically 3 or 4 inch diameter

core) strength into “150 mm saturated cube” strength depends upon :

Page 30: Non Destructive Testing

Cont……………………………………….. 1. effect of coring 2. shape factor 3. size effect 4. direction of coring w.r.t. placing of concrete 5. h/d ratio With so many factors contributing to the final “150

mm saturated cube” strength, the strength variation may be + / - 10% - 15%. However, it can be used to confirm the results of UPV differing largely in the values & also for co-relation. Hence the UPV & core results should be judiciously used, interpreted & co-related.

Page 31: Non Destructive Testing

Limitations of NDT !!!!!!!!!!!!!!!!!!!!!!!!! CORELATION BETWEEN MEASURED

PARAMETER AND CONCRETE STRENGTH IS NEVER EXACT.

EFFECTIVENESS OF NDT REDUCES WITH HETEROGENEITY OF THE MATERIAL

RESULTS ARE DEPENDENT ON TOO MANY PARAMETERS

NORMALLY ACHIEVEABLE LEVEL OF ACCURACY IS + 25%

INTERPRETATION OF RESULTS REQUIRE INTUITIVE JUDGEMENT

Page 32: Non Destructive Testing

THANK YOU