Top Banner
New construction project: Casa Passiva, Mariano Comense An avant garde low-energy house – with environment-friendly solar technology by ELCO Something completely new and innovative with regard to ecological technology and domestic comfort – that was the central idea around which the “passive house” in Mariano Comense, a small town near Lake Como in the region of Lombardy, was built. At the same time, this project was a great challenge to all those involved in its planning, because it was unique with regard to energy- efficiency and energy saving. At the start of the planning phase, there were as yet no buildings of this kind in Lombardy – and therefore no reference data. ELCO’s contributions to this low-energy house project were an AQUATOP T heat pump for heating and warm water processing, and a solar installation on the roof of the house to heat the swimming-pool and for warm water. For this Builder Frigerio Aldo, Pier Giovanni Loc. Rogeno (LC) Location Via Pio X n. 25 Mariano Comense I-22066 Como purpose, 5 SOLATRON flat collectors with a total area of 10 m² were installed. To optimally catch the sun’s rays, the collectors were installed at an angle of 30°. BENEFITS Efficiency Maximum yield, thanks to highly efficient full-surface copper absorbers Maximum energy efficiency – corresponds to Energy Class A • Long lifetime Convenience Self-supporting collector housing with closed aluminium tray Hydraulically optimised modules, mounted vertically or horizontally Simple transportation and easy installation through low weight of modules Long-lived and reliable, made of high-quality components Savings Energy requirement lowered to approx. 10 kWh per m² per year • Heavy reduction in general energy costs • Significant lowering of the CO 2 emissions • Short “running warm” time; no wastage of water Planning Studio Ingegneria Benfatto Enrico, Via Capolino 29 I-23900 Lecco (LC) Installation TERMOISOVER IND. s.r.l. Corso XXV Aprile 62 22036 Erba (CO) Frigerio Aldo, Pier Giovanni Via Provinciale 36 I-23849 Loc. Rogeno (LC)
2

New construction project: Casa Passiva, Mariano Comense An ...elco.net/referenzfilter/en/wp-content/uploads/sites/9/2013/11/casa... · New construction project: Casa Passiva, Mariano

Aug 29, 2019

Download

Documents

DinhThuy
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: New construction project: Casa Passiva, Mariano Comense An ...elco.net/referenzfilter/en/wp-content/uploads/sites/9/2013/11/casa... · New construction project: Casa Passiva, Mariano

New construction project: Casa Passiva, Mariano Comense

An avant garde low-energy house – with environment-friendly solar technology by ELCO

Something completely new and innovative with regard to ecological technology and domestic comfort – that was the central idea around which the “passive house” in Mariano Comense, a small town near Lake Como in the region of Lombardy, was built. At the same time, this project was a great challenge to all those involved in its planning, because it was unique with regard to energy-effi ciency and energy saving. At the start of the planning phase, there were as yet no buildings of this kind in Lombardy – and therefore no reference data.

ELCO’s contributions to this low-energy house project were an AQUATOP T heat pump for heating and warm water processing, and a solar installation on the roof of the house to heat the swimming-pool and for warm water. For this

Builder Frigerio Aldo, Pier Giovanni Loc. Rogeno (LC)

LocationVia Pio X n. 25 Mariano Comense I-22066 Como

purpose, 5 SOLATRON fl at collectors with a total area of 10 m² were installed. To optimally catch the sun’s rays, the collectors were installed at an angle of 30°.

BENEFITS Effi ciency• Maximum yield, thanks to highly effi cient

full-surface copper absorbers• Maximum energy effi ciency – corresponds

to Energy Class A • Long lifetime

Convenience • Self-supporting collector housing with

closed aluminium tray

• Hydraulically optimised modules, mounted vertically or horizontally

• Simple transportation and easy installation through low weight of modules

• Long-lived and reliable, made of high-quality components

Savings• Energy requirement lowered to approx.

10 kWh per m² per year • Heavy reduction in general energy costs • Signifi cant lowering of the CO2 emissions • Short “running warm” time; no wastage of water

PlanningStudio Ingegneria Benfatto Enrico, Via Capolino 29I-23900 Lecco (LC)

InstallationTERMOISOVER IND. s.r.l. Corso XXV Aprile 62 22036 Erba (CO) Frigerio Aldo, Pier Giovanni Via Provinciale 36 I-23849 Loc. Rogeno (LC)

elco_Ref_Casa_Passiva_EN 4c RZ.indd 1elco_Ref_Casa_Passiva_EN 4c RZ.indd 1 12.01.11 14:5512.01.11 14:55

Page 2: New construction project: Casa Passiva, Mariano Comense An ...elco.net/referenzfilter/en/wp-content/uploads/sites/9/2013/11/casa... · New construction project: Casa Passiva, Mariano

AQUATOP T heat pumps with free energy

The operating costs of the AQUATOP T heat pumps are well

below those of conventional heating systems. They exploit the

energy stored in the surroundings (e.g. in the ground water) to

generate warmth for heating. In addition, AQUATOP T heat

pumps relieve environmental stress, because they produce no

CO2 emissions. AQUATOP T heat pumps are characterised by

their top quality and reliability, and bear the “Geprüfte Qualität”

(“Certifi ed Quality”) heat pump seal of approval, which is re -

cognised in Germany, Austria and Switzerland.

ELCO Italia S.p.A.

Via Roma, 64

I-31023 Resana (TV)

Tel. +39 (0) 423 71 60

Fax +39 (0) 423 71 6380

www.elco.net

The new system

The upper limit for energy consumption in the villa was set

very low: 10 kWh per m² per annum. For sake of comparison,

90 to 110 kWh per m² per annum is the standard value accor-

ding to Italian legislation. The heating and warm water pro -

cessing are taken care of by an AQUATOP T heat pump – an

innovative solution for house-builders who want to make

themselves completely independent of fossil energies within

their own four walls. AQUATOP T heat pumps generate con-

venient heating warmth with free energy from the surrounding

air and from the soil.

An ELCO solar installation, consisting of 5 SOLATRON A 2.3

fl at collectors, is used to heat the swimming-pool and to supple -

ment the warm water processing. The fl at collectors deliver high

energy yields. This permits savings of up to 60 % in the amount

of energy needed for warm water in a single-family dwelling-

house in the course of a year. SOLATRON A 2.3 combines

quality components and effi cient technology with ease of use

and environmental acceptability.

New construction project: Casa Passiva, Mariano Comense

Energy saving on a large scale: with leading-edge ELCO technology

The project was born of the idea of a family who wanted to

develop something completely new and innovative in the way

of house and home comfort. The objective was to achieve

maximum comfort with environmentally friendly technologies,

both for those who live in the house and for the community.

The house has 3 storeys: a ground fl oor (130 m²) with kitchen,

living-room, 2 bathrooms and 1 bedroom; a 1st fl oor with

2 rooms and 2 bathrooms; and a basement with a garage

and an equipment-operating room.

The Casa Passiva – an exemplarylow-energy house

New system

SOLATRON A 2.3

2.0 m2

2.3 m2

1.7 litres vertical,

1.9 litres horizontal

1,097 x 2,097 x 103 mm vertical,

2,097 x 1,097 x 103 mm

horizontal

40 kg vertical,

41 kg horizontal

Equipment

Flat collector

Effective absorber area

Gross area

Volume of heat carrier

Dimensions

(W x H x D)

Weight of collector

module

elco_Ref_Casa_Passiva_EN 4c RZ.indd 2elco_Ref_Casa_Passiva_EN 4c RZ.indd 2 12.01.11 14:5512.01.11 14:55