    NEED FOR ENERGY CONSERVATION

    2

    Now the entire world is craving for new and long lasting energy resource.

    Fossil fuel resources are fast depleting and may not last more than few

    centuries, besides not being very eco friendly.

    Generation of heating, refrigerating and air conditioning utilities typically

    account for40 to 70% of the electrical power consumed in various domestic,

    commercial and industrial sectors.

    Meeting the peak demand of electricity with limited generation and

    transmission infrastructure has been a challenge.

  • 7/31/2019 Mwe Air 2 Water Hp

    3/23

    MWE AIR To Water / Steam Heat Pump

  • 7/31/2019 Mwe Air 2 Water Hp

    4/23

    What is MWE Air 2 Water HeatPump?

    1.Compressor: This increases the pressure of the refrigerant so that it will accept the

    maximum amount of heat from the air.

    2.Condenser: Patented Coils that move heat to or from the outside air.

    3.Evaporator: Patented Coils that move heat to or from the air inside the home.

    4.Air handler: Fan that blows the air into the ducts of the home.

    5.Reversing / Two way valve: Changes the heat pump from air conditioning to heating,

    and vice versa. This is not part of the thermostat.

  • 7/31/2019 Mwe Air 2 Water Hp

    5/23

    Value Proposition

    MWE in technical collaboration with IIT Bombay hasworked hard to build one of the best reliability records inthe industry and we want to help you make the most of

    the energy consumed. Its your best option for maximizingyour Utility year-round with comfort and economy

    MWE Air to Water / steam Heat Pump with all in one function

    Fresh Air Conditioning

    Hot or Chilled Water

    Hot Air

    Steam

  • 7/31/2019 Mwe Air 2 Water Hp

    6/23

    Excess heat used forcloth drying orrejected to ambientair Tap water being

    heatedBetween 45 to 55 0C

    Supply electricity

    Conditioned room air oroutlet to ambient

    Evaporator

    Expansiondevice

    Condenser

    Schematic For SimultaneousHeating and Cooling

  • 7/31/2019 Mwe Air 2 Water Hp

    7/23

    Line Diagram

    Water Storage

    Cold Water Header

    Chilled Air can

    be circulated

    through FCU or

    Radiant Panel

    Hot water out

    @ 55O C to the tank

    or directly to the

    desired applicaiton

    Hot water out

    @ 55O CWater in @ 30O C

    Evaporator

    Compressor

    Expansion Valve

    Condenser

  • 7/31/2019 Mwe Air 2 Water Hp

    8/23

    MWE Air To water Heat Pumps

    Compact Design: For 1.5 TR, space required is 1 m2 with height of about 1.8 m

    High Reliability: field-proven patented vented-double-wall Tube-Tube Heat Exchangers

    are used.

    Energy Efficient: can heat tap water from 10 oC to 55 oC with a heating Coefficient of

    Performance (C.O.P.) of 3 to 4; overall energy saving would be over 40%to 60% when

    compared with electric water heating and conventional water chilling or air conditioning

    Low Internal Volume: fast start-up; hot and cold Air generation in minutes

    Easy to Install and Commission: once through design - can generate hot or cold water

    streams without the use of re-circulating pumps in most cases

    Wide Selection Range: 1, 1.5, 2, 3, 4 and 5 TR and multiples heating and cooling

    capacities.

    Maintenance Friendly: Descaling can be done using clean-in-place system

    Durable: no worries about over pressurization

    Easy to Transport: can be transported as a single factory assembled unit

  • 7/31/2019 Mwe Air 2 Water Hp

    9/23

    MWE AIR To Water Heat Pump Cateringto Space Conditioning

    Reversing / Two way valve: Changes the heat pump from air conditioning to

    heating, and vice versa. With this you can maintain the temperature through out the

    year without considering

  • 7/31/2019 Mwe Air 2 Water Hp

    10/23

    Classificationas per customers requirement

    Cold Utility: comfort airconditioning, cold store operation

    Hot Utility: heating water, direct

    heating of process fluids likecleaning solutions in industrialwashing machines, drying agroproducts, regeneration ofdesiccants which can be used fortaking care of latent cooling load,

    etc

    air2water

  • 7/31/2019 Mwe Air 2 Water Hp

    11/23

    Air-Conditioning

    A pure Air Conditioning can be provided.

    Hot Air during low ambient temperature and Cold Air during high

    ambient temperature is possible.

    Space heating and Cooling is also possible by using Proprietarydesigned Radiant Panel or Fan coil units

    Every Radiant Panel will have flow control knob so that Individual can

    make himself comfortable.

    Unused capacity of hot or cold water can circulate through insulated

    pipe to other facility like office, Hostel, residential areas etc.

    The system uses a high performance, patented Tube 2 Tube

    technology to transfer the heat from Air to Water.

    11

  • 7/31/2019 Mwe Air 2 Water Hp

    12/23

    Radiant Cooling System

    A radiant cooling system utilizes large surfaces, such as the floor, wall or ceiling.

    Rooms are cooled by circulating water through embedded plastic tubes, excess

    heat being absorbed by the surface.

    Air change rates can be reduced to a minimum.

    Radiant cooling system components can also be concealed, which enhances

    the architectural concept and improves the rooms aesthetics.

    Similarly to radiant heating, the temperature of the water circulating in the pipes

    and room temperature are always close to one another, creating gentle,

    comfortable cooling.

    Cooling energy consumption is reduced, a key factor in obtaining moderate

    energy bills.

    It is a genuine benefit of the system that it allows you to install both heating and

    cooling based on a single system 12

  • 7/31/2019 Mwe Air 2 Water Hp

    13/23

    ADVANTAGE

    Very Low Operating CostGeneration of multiple hot and/or cold utilities simultaneously give addedflexibility in matching the heating and cooling effects produced by MWE HeatPumps.

    Eliminates Conventional Fuel Boiler CostsIt completely eliminates all costs associated with boiler system such aschimneys, ducting, fans, fire-safety system and fuel piping system.

    Eliminates Hazards

    It completely eliminates the needs to handle any hazardous fuels Environment

    Eliminates CO2 emission and maintains cleaner environment

    Big Reduction in Maintenance CostsCompared to conventional systems, the maintenance costs is minimal. MWESystem only requires yearly checks and cleaning.

    Free Cooling

    Chilled fresh air at about 7C less than the ambient can be channelled to thedesired location for spot cooling' or ventilate an enclosed area. Hence,downsizing the air-conditioning equipment is also possible

    Attractive Pay-Back PeriodAttractive paybacks, in the range of 3 to 18 month, are achieved in most ofthe cases with proper application engineering.

  • 7/31/2019 Mwe Air 2 Water Hp

    14/23

    Comparative scenario with SWH

    14

    Particulars Solar Water Heater (SWH) MWe Air to Water Heat pump

    ENERGY CONSUMPTION

    Northern Hemisphere60% solar and 40% on ElectricHeater. In such conditions Solarwater heater are inefficient.

    Designed to Operate in extremefrom -15C to +48C.

    Lack of Solar Insolation / RadiationHigher Nos. of Panels / tubes arerequired to be installed

    Not depended on Sun but onambient air which is naturallyavailable.

    Frost IssueDoes not operate in sub ZeroTemperature

    Operates in Ambient temperaturethat is upto -15C. DeFrosting is notrequired upto -5C.

    Central and Southern Hemisphere

    80% solar and 20% on ElectricHeater

    As the ambient temperature iswarm, coefficient of Performancecan be 4.5 resulting is less powerconsumption.

    Chilled Dehumidified Fresh AirNo Chilled Air produced

    Chilled Dehumidified Fresh Air thatis normally by product can be re-circulated and be utilized inSummers.

    Energy Saving in comparison toDiesel, Wood, Electric Heater andLPG

    Depends upon Location butgenerally between 60% to 80%

    Saving is upto 75%.

  • 7/31/2019 Mwe Air 2 Water Hp

    15/23

    HEATING CONSISTENCYParticulars Solar Water Heater (SWH) MWe Air to Water Heat pump

    Winter

    Heating Consistency getseffected during winter As inletwater temperature drops to theextent of 10C.

    Heating at committedtemperature is consistentthroughout the year.

    Operation Hours

    Depending upon solar Insolation /Radiation.

    MWE Systems are Optimumdesigned to work in lessoperation hours. Monthly Ambienttemperature and Earth skintemperature is considered beforesuggesting the right system tocustomer.

    Constant Hot Water

    Once the 50% of Hot Water isdrawn especially during earlyhours of morning, watertemperature gets affected. As

    Solar radiation commences from9.00 AM, water heatingcommences late.

    Does not get affected.

    Seasonal conditions

    Seasonal conditions get affectedas Primary fuel is Solar. Andoperated for only 6 to 8 hours adays

    Does not get affected as heat isabsorbed from Ambient Air andthe system can operate24*7*365.

    Water FlowWater flow is required to becontrolled

    Water flow is not required to becontrolled. 15

    Comparative scenario with SWH

    C ti i ith SWH

  • 7/31/2019 Mwe Air 2 Water Hp

    16/23

    PRICINGParticulars Solar Water Heater (SWH) MWe Air to Water Heat pump

    Subsidy

    Available Not available at present

    Cost

    Small sized Solar Water heater arecompetitively priced. Larger size SolarWater heater are expensive and also callupon regular maintenance.

    Price of MWe Air 2 water heat pump arepriced at par with smaller solar waterheater. In comparison to larger lpdrequirement MWe heat pump are dearerby 30% to 45%.

    Saving on TankStorage tank with full capacity is requiredto be installed.

    Storage Tank of 50% of total liters per dayis required to be installed.

    Payback

    Early payback Early pack with all alternative fuels. In

    comparison to SWH depending upon thegeographical location payback maychange.

    INSTALLATION AND COMMISSIONING

    MethodologyCritical Easy simple plug and play,

    SpaceLarge shadow free space required 2% to 5% of SWH space required. Can be

    installed at any convenient space.

    Water Tanks

    Insulated water Tanks of full capacity is

    mandatorily required

    Insulated water tank of SS304 of 50% of to

    total liters of hot water demand during theday is required. This amounts to saving inspace.

    Place of Installation Only on shadow free rooftop Can be installed anywhere.

    MobilityFixed Heat pump without water tank can be

    mobile as in summers cold air can bedirectly blown inside the premises.

    Direction and Position of installationSolar is required to installed on southfacing

    Independent of Direction.

    Installation limitationHigh rise buildings, Commercial places,Monuments, etc.

    No such limitations. 16

    Comparative scenario with SWH

  • 7/31/2019 Mwe Air 2 Water Hp

    17/23

    MWE Air to Water Heat Pump with Contacting

    Device

    17

  • 7/31/2019 Mwe Air 2 Water Hp

    18/23

    Introduction

    This is a Novel MU_HP with Adiabatic Contacting Devices, MWE MU_HPwCD,used as Evaporative Condensers using three section aluminium extrusion incorrosion resistant FRP structure.

    This sub-system will be integrated with the Air Conditioning.

    It will be used for DX Air Conditioning, Potable Water Heating and Potable Water

    Pre-Chilling.

    Mwe MU_HPwCD is based on the reliable and versatile Vented-Double-WallTube-Tube Heat Exchanger, Multi-Utility Vapour Compression SystemandContacting Device for Effective Heat and Mass Transfer designs

    This unit is developed in collaboration with the Heat Pump Laboratory IIT

    Bombay, HPL_IITB, Payback period for the MU_HPwCD is typically in the range of 6 to 12 month

    depending on the usage.

    18

  • 7/31/2019 Mwe Air 2 Water Hp

    19/23

    Energy Conservation using MultiUtility Heat Pump with ContactingDevice: MweMU_HPwCD Improve the Performance of Air Cooled Ductable Split Air Conditioners to Reduce

    Operating Cost

    Using Patented modular Contacting Device, CD

    Super Heat Recovery Water Heater, SHR_WH

    Novel Potable Water Instant Prechiller, PW_IPC

    Increase Cooling Coefficient of Performance, COPc 15 to 36%

    Saving would depend on outdoor weather condition

    Saving will be more in summer and less in monsoon

    Increase Cooling Capacity using the same Compressor , Qc 5 to 15%

    Overall Energy Saving Compared to DX Air Cooled Split AC 20 to 39%

    MU_HPwCD Module Size would be 1.5 TR

    Suitable for retrofitting with various capacity Air Cooled Split Air Conditioners

    19

  • 7/31/2019 Mwe Air 2 Water Hp

    20/23

    Tri generation of Air conditioning,Hot water and Steam

    20

  • 7/31/2019 Mwe Air 2 Water Hp

    21/23

    IMPACT OF SUCCESSFUL DEPLOYMENT OFVARIOUS TECHNOLOGIES

    Saving in fuel or electricity while co-generating hot utilities using will be in the range of12 to over 90%

    Saving in fuel or electricity to generate cooling effect will be 5 to 20%

    Saving in fuel or electricity while recovering waste heat using will be over 90%

    Peak electricity demand for electric water heating will be lowered by 95%

    Impact on energy usage will be as follows:

    Saving in fuel and electricity will lead to corresponding lowering of emissions

    Recovering waste heat will lead to reduced thermal pollution

    Environment and ecological benefits will be as follows:

    Direct employment generation to manufacture, retrofit and service along with

    substantial indirect employment generation in agro-processing units in rural areas foron-far and forest based products will take place.

    Additional employment will be generated by collection sorting/grading, cleaning,precooling/drying, packaging, activities associated with agro-processing.

    Social Benefits

  • 7/31/2019 Mwe Air 2 Water Hp

    22/23

    Conclusion

    Techno-economic benefits are very attractive and provideshigh saving.

    Generation of multiple hot and/or cold utilities simultaneouslygive added flexibility in matching the heating and coolingeffects

    Attractive paybacks, in the range of 3 to 18 month, are

    achieved in most of the cases with proper application

    engineering.

    Various opportunities for utilizing the surplus hot utility fordrying and dehumidifying using liquid desiccants

  • 7/31/2019 Mwe Air 2 Water Hp

    23/23

    Revenue generated through recovered heat can more thanpay for the cost of operating the cold utility generators!

    Increasing energy costs and raising concern forenvironmentheightens the need to go for heat recovery systems.

    Installations have been working satisfactorily for several years,

    in many cases without a service call.

    Co-production of multiple utilities using a single system helpsreducing space requirement, initial cost and maintenance.

    CO2 emissions are also reduced and electrical demand

    reductions are also realized. Proper application engineeringcan ensure a Win-Win situation of simultaneously reducinginitial and operating cost.

    Conclusion