Top Banner
Hearty Welcome
31

Matrix Security Solutions: PROPAC

Apr 16, 2017

Download

Technology

Matrix Comsec
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Matrix Security Solutions: PROPAC

Hearty Welcome

Page 2: Matrix Security Solutions: PROPAC

PROPAC CFAP Conventional Fire Alarm Panel

Page 3: Matrix Security Solutions: PROPAC

Presentation Outline

Working of Fire Alarm System

PROPAC Introduction

PROPAC Architecture

Key Features of PROPAC

Applications of PROPAC

Page 4: Matrix Security Solutions: PROPAC

How does Fire Alarm System Works?

Receive Information from Sensors ,Detectors & MCPs

Unique Code Emergency Responders locate the

source of the alarm

After Fire is Extinguished, Panel will be reset to protect

the building continuously

Response through Sounders

or NACs

1

2

3

4

Page 5: Matrix Security Solutions: PROPAC

PROPAC INTRODUCTION

Page 6: Matrix Security Solutions: PROPAC

Introduction

Defining PROPAC CFAP

A Powerful and Protective Conventional Fire Alarm Panel

Continuously Monitor Smoke, Heat, Flame and Spark

Works on Real Time Response

Reduce the Risk of Equipment Damage and Loss of Life

Used for an Office, Building, Apartment, Home, Small Industrial

Plant etc

Page 7: Matrix Security Solutions: PROPAC

Feature Highlights

Built Using Latest Micro-Controllers and ADCs (Analog to Digital

Convertors)

Rapid and Accurate Response

Interface through LCD, Coloured Status Indicators and Touch Sense Keys

Easy to Setup and Operate

Rugged and Weather-Proof Enclosure

Supports Wide Range of Sensors and Detectors

Quick Configuration

Page 8: Matrix Security Solutions: PROPAC

PROPAC ARCHITECURE

Page 9: Matrix Security Solutions: PROPAC

PROPAC Architecture

Battery Backup

24V DC

Mimic Panel

Fire Relay

Aux IN Port Fault Relay RS-485

Bell

Strobe Sounder Strobe

EOL

ZONE 1

Sounder Circuit

MCP

ZONE 2

Smoke & Heat Detectors

ZONE 4

ZONE 3

32 Devices per Zone

Ethernet Port

COSEC

PC

Page 10: Matrix Security Solutions: PROPAC

PROPAC Architecture

PROPAC Family Consists of 2, 4 and 8 Zones

Allowing 32 Sensors and Detectors per Zone

Allowing 16 Mimic Panel on RS485

Integration with Fire Relay, Fault Relay, Auxiliary Input and RS485 Relay

Ports

Ethernet Port for Easy Setup and Events Download

IDC (Initiating Device Circuits): 2, 4 and 8 Style-Y (Class-B)

NAC (Notification Appliance Circuits): 2 and 4 Style-Y (Class-B)

Page 11: Matrix Security Solutions: PROPAC

KEY FEATURES OF PROPAC

Page 12: Matrix Security Solutions: PROPAC

Preventive Maintenance

Deactivation of Any Zone on Temporary Basis

Variety of Inspection Tests like; Sounder Test, Lamp Test, Walk

Test etc

Evaluation Functionality of the System Time-to-Time

Integration

Third Party Hardware Devices like; Water Sprinkler, PA/VA

System, Gas Release Panels

Key Features of PROPAC

Page 13: Matrix Security Solutions: PROPAC

Third Party Repeaters like; Mimic Panel and other Annunciators

through RS485, for up to 16 Devices in a Row

Third Party Relay Based Devices

Web Configuration Tool

User Friendly Web Configuration Tool called Jeeves

Easy to Program and Ready to Use within Few Minutes

Downloadable Events Log File in Readable Format

Key Features of PROPAC

Page 14: Matrix Security Solutions: PROPAC

Key Features of PROPAC

User Friendly Menu

User Friendly, Interactive, LCD Display Based Menu to Configure

and Activate Features

Menu can handles tasks like;

- Status Check - LAN Settings

- Setting default password - Reset

- Configuration - Maintenance

- Clear log events

Page 15: Matrix Security Solutions: PROPAC

Users Access Levels and Codes

Offers 4 Different Users Levels and Codes to Keep Panel Safe

and Secure

Level based Rights to Different Users to Access Different

Functions

User can View Zone Status, Battery Status, Event Logs, Mute

Buzzer, Silence Sounders, Reset Panel etc.

Key Features of PROPAC

Page 16: Matrix Security Solutions: PROPAC

User Interface and Display

Provides Multiple Pathways between Panel and User like;

- Touch Sense Keypad - 2 x 24 Characters LCD

- 33 Status LEDs - Built-in Buzzer

Fire Detection and Notification

Multi Zone Fire Detection through Sensors, Detectors & Manual Call Points

Notification through Indicators, Zone Alarm, Panel Buzzer, Sounder and

Strobe

Key Features of PROPAC

Page 17: Matrix Security Solutions: PROPAC

Detectors

Sensors

Manual Call Point

Style-Y (Class-B) IDC

Style-Y (Class-B) NAC

Strobe

Hooter

Sounder Strobe

Fire Detection and Notification

Page 18: Matrix Security Solutions: PROPAC

Fire Relay and Integration

Integration to Access Control and Other Devices through Fire Relay

Whenever Fire is Detected in Any Zone, Access Control System Opens

All the Doors to Evacuate the Place.

Fault Detection and Reporting

Detection of Different Faults like General Faults, Sounder Faults, Zone

Faults

These Alerts are Reported to Admin via Audio Visual Indicators

Key Features of PROPAC

Page 19: Matrix Security Solutions: PROPAC

Delayed Mode

Postpone Activation of Sounders for Some Time (1 to 9 minutes) to

Avoid Panic

Helpful in Sensitive Areas like Hospitals, Server Rooms,

Pharmaceutical Companies

Evacuation or Fire Drill

Activate NACs (Sounders) for the Decided Period by User, Mainly for

the Purpose of Mock Drill

Key Features of PROPAC

Page 20: Matrix Security Solutions: PROPAC

Various Tests for Maintenance of PROPAC CFAP

Sounder Test: Monitor Proper Functioning of Sounders

Lamp Test: Monitor Proper Functioning of LEDs and Internal

Buzzers

Walk Test: For Fault Reactivation Maintenance Facility

Stop Test: Select Walk Test Inactivity Timer Ranges from 10 to

60 Minutes Using the Menu

Key Features of PROPAC

Page 21: Matrix Security Solutions: PROPAC

Events Log Download

PROPAC can Log up to 999 Events or Transactions

It Consist of Alarm, Fault And Enable/Disable Events

Download from Controller through Ethernet

Configuration through Ethernet

System Configuration through Ethernet

Upgrade the Firmware through Ethernet

Key Features of PROPAC

Page 22: Matrix Security Solutions: PROPAC

APPLICATIONS OF PROPAC

Page 23: Matrix Security Solutions: PROPAC

All Doors Opened Automatically

Fire Brigade

Fire Relay

Fire Relay

Fire

Rel

ay

CentralizedMonitoring

Station

Zone 1

Zone 2

Zone 3

Zone 4

Zone 2Alert

Access Control unrestricted

Fire Alarm

Fire Fighter

Fire Relay Applications

Page 24: Matrix Security Solutions: PROPAC

Fire Relay

Fire Sprinkler System

Fire Sprinkler

Corporate office

Sensors

Integration with Fire Sprinkler System

Page 25: Matrix Security Solutions: PROPAC

Auxiliary Input

Sounder Circuit

Class Change in School

Page 26: Matrix Security Solutions: PROPAC

Integration with Access Control System

Integration with Fire Sprinkler System, Gas Release Panel, Relay

based Devices etc.

Supervise and Monitor All IDC Circuits

Fire Detection and Notification

Fault Detection and Reporting

Regular Preventive Maintenance

Other Applications

Page 27: Matrix Security Solutions: PROPAC

Target Customers

Government Sectors

Shopping Malls

Hospitals

Industries & Mills

Corporate Offices

Large Enterprises

Financial Institutes

Hotels

Petrol Pumps

Page 28: Matrix Security Solutions: PROPAC

Advantages of PROPAC

Real Time Operation

Rapid and Accurate Response

Easy Interface through Interactive Front Panel

Easy Configuration and Set up of the System

Perpetual Fire Monitoring and Controlling

Page 29: Matrix Security Solutions: PROPAC

USPs of PROPAC

Ethernet Connectivity

Web based Configuration

Class Change Application

Preventive Maintenance Facility

Integration with Wide Range of Detectors

16 Mimic Panel Support through RS485

999 Events Log and Download through Ethernet

Page 30: Matrix Security Solutions: PROPAC

Thank You

Copyright © Matrix ComSec 2009-2010

Page 31: Matrix Security Solutions: PROPAC

For Further Information Please Contact: Email ID: [email protected]

Tel: +91 265 2630555

Visit us at www.MatrixComSec.com

Version: V1R2