MAGNETIC FLUORESCENT BALLAST ELECTRONIC FLUORESCENT BALLAST Our LAMP/BALLAST CROSS REFERENCE helps customers identify which Inter-Global ballast operates which specific lamps. A1 For
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
LAMPS
CFT5W/G23 X X X
CFT7W/G23 X X X X X
CFT9W/G23 X X X X X X X
CFT13W/GX23 X X X X X X X X X
CFQ13W/GX23 X
CFQ13W/GX23 X X X X X X X X
CFQ22W/GX32d X
CFQ28W/GX32d X
FT18W/2G11 X X X
CFT5W/2G7 X
CFT7W/2G7 X
CFT9W/2G7 X
CFT13W/2GX7 X X X
CFTR13W/GX24q X
CFTR18W/GX24q X X X
CFTR26W/GX24q X X
CFTR32W/G24q X X X
CFM18W/2G10 X
CFQ13W/G24q X X X
CFQ18W/G24q X X X
CFQ26W/G24q X X X
CFQ32W/G24q X
IG8
OR
IG8
OP
IG9
O
IG9
OP
IG13
OP
IG13
OS
IG22O
P
IG28
0P
IG12O
22O
IG12O
22O
B
IG13
OSN
F
IG13
CP
IG9
CP
IG9
C
IG13
C
IG13
ML
PS2/80
9M
L120
PS2/813
ML1
20
PS2/83
2EL120
IG5
13
ELS
IG13
20
ELSXH
IG13
20
ELSX
IG25
32ELSX
IG213
20
ELSX
IG226
32ELSX
COMPACT FLUORESCENT LAMP/BALLAST CROSS REFERENCE
MAGNETIC FLUORESCENT BALLAST ELECTRONIC FLUORESCENT BALLAST
Our LAMP/BALLAST CROSS REFERENCE helps customers identify which Inter-Global ballast operates which specific lamps.
A1For more information contact our sales department at 1-800-325-7364 or visit www.interglobal-inc.com 1709.1
Catalog Circuit Input Type Power Ballast Input SoundNumber Volts Wattage Number Factor Factor Current Rating
IG220N-120P 120 36 MAG. N .70 .75 A
LINEAR FLUORESCENT BALLAST
• Automatic reset able thermal disconnect• Standard leads 105˚C 18AWG wire (customer specified lengths)• Normal Power Factor• Suitable for (2) F15T8 15W, (2) F15T12 15W, or
(2) F20T12 20W lamps• Contains no PCBs
UL and CUL listed
LAMP
LAMP
REDRED
BLUEBLUE
YELLOWYELLOW
BLACKWHITE
LINE
BALLAST
Lamps must be mountedWithin 1/2" of grounded
metal reflector
For warranty information refer to Inter-Global’s BALLAST LIMITED WARRANTY in the back of the Ballast section of this catalog.
Wattage Circuit Catalog Type Power Ballast Input Sound Min. StartVolts Number Factor Factor Current Rating Temp
13 120 IG13ML-120 MAG. 0.67 (NPF) 85.1 0.30 A 32˚F
BALLAST SINGLE LAMP
• A reset able thermal disconnect from Texas Instruments• Standard lead length 13” 105˚C 18AWG wire.• Suitable for PLC Quad 13W lamp.• Contains no PCBs
UL and CUL listed
A7
For warranty information refer to Inter-Global’s BALLAST LIMITED WARRANTY in the back of the Ballast section of this catalog.
CFT5W/G23 7CFT7W/G23 **PS2/809ML-120 120 MAGNETIC 0.20 .864 7 32˚F White A UL(IFFX), CUL(IFFX7)CFT9W/G23 10
CFT13W/GX23 **PS2/813ML-120CFQ13W/GX23 •PS213ML-120 120 MAGNETIC 0.30 .851 8 32˚F Black B UL(IFFX), CUL(IFFX7)
CFQ26W/G24 106.5CFQ32W/G24
PS2/832EL-120 120 ELECTRONIC 0.45 .920104.8
0˚F Orange C UR(IFFX2), CUR(IFFX8)
POWERSOCKET
• Operating Voltage: 120 VAC ± 10%• Frequency: 60Hz (Electronic 50/60Hz)• Protection: Class P Thermal Protection• Over Current: Fuse (Electronic)
• Min. Starting Temp: 0˚F (-17.78˚C)* 32˚F Min. Starting Temp
• Max. Case Temp: 158˚F (75˚C)• FCC, 47 CFR, Part 18 Consumer Limits (Electronic)
• Power Factor: Normal (MH Models - High)• Lamp Current Crest Factor: <1.7 (Electronic)• End of Lamp Life Protection (Electronic)
• Mounting bracket for Powersocket• Made of steel• Available in white only• FIts all Powersocket models• Solves mounting issues
The Powersocket™ was designed to meet the need of fixturemanufacturers to build competitive compact fluorescent fixtures.Making a high quality, compact fluorescent fixture is no moredifficult or time consuming than building an incandescent fixture.
Suitable for one CFT5W/G23, CFT7W/G23, CFT9W/G23, CFT13W/GX23,CFQ13W/GX23, CFQ26W/G24*, or CFTR32W/G24* lampClass A Sound RatingMagnetic and Electronic Models AvailableSmall compact size
Electronic models are more efficient compared to standard magneticballasts, have end of life lamp protection, and eliminate strobingContains No PCBsRapid Start (Electronic)
Features & Benefits
Lamp Catalog Line Type Line Ballast THD Min Start Color Case ULNumber Volts Current Factor Percent Temp Code Size
8 Series
SPECIFICATIONS
M002PT
** High Power Factor available as special order. • Leads extend from side
2”(5
1mm
)
2.24
”(5
7mm
)
1.85
”(4
7mm
)
1.69
”(4
3mm
)
2.36
”(6
0mm
)
2.69” (68mm)
2.69” (68mm)2.69” (68mm)
1.96
”(5
0mm
)
1.77
”(4
5mm
)
1.69
”(4
3mm
)
1.38
”(3
5mm
)
Leads extended from sideLeads extended
through Bottom Hole
2”(5
1mm
)
2.24
”(5
7mm
)
1.85
”(4
7mm
)
1.69
”(4
3mm
)
2.36
”(6
0mm
)
2.69” (68mm)
2.69” (68mm)2.69” (68mm)
1.96
”(5
0mm
)
1.77
”(4
5mm
)
1.69
”(4
3mm
)
1.38
”(3
5mm
)
Leads extended from sideLeads extended
through Bottom Hole
US Patent DES 415,103
For warranty information refer to Inter-Global’s BALLAST LIMITED WARRANTYin the back of the Ballast section of this catalog.
• Operating Voltage: 120 VAC ± 10%• Frequency: 50/60Hz• Protection: Class P Inherent Thermal Protection
• Regulatory Approvals: UL, CUL Listed• Over Current: Fuse• Min. Starting Temp: 0˚F (-17.78˚C)
• Max. Case Temp: 158˚F (75˚C)• FCC, 47 CFR, Part 18 Consumer Limits• Type 1 Outdoor, Normal Power Factor
SPECIFICATIONS
Wide lamp versatility, suitable for one F14T8, F14T12, F15T8, F15T12, F17T8, F18T8, F20T8, F20T12, or FC8T9(22W)G10q lamp.Optional pre-wired plug for CIRCLINE lamps (IG13-20EL/T9)Class A Sound RatingMore efficient compared to standard magnetic ballastsLead wires do not interfere with mounting holes
Contains No PCBsEliminates strobingThermal pottingMetal enclosureRapid Start
• One Lamp• Multi-Watt• Small Case Size• Lightweight• Versatile• Energy Saving
Wide lamp versatility, suitable for one CFQ13W/G24q, CFT13W/2GX7,CFM13W/G24q, F14T8, F14T12, F15T8, F15T12, F17T8, F18T8, CFTR18W/GX24,CFQ18W/G24q, FT18W/2G11, F20T8, F20T12, or FC8T9(22W)G10q lampClass A Sound RatingEnd of Lamp Life ProtectionMore efficient compared to standard magnetic ballastsLead wires do not interfere with mounting holes
• One Lamp• Multi-Watt• Small Case Size• High Heat• Lightweight• Energy Saving
Wide lamp versatility, suitable for one CFQ13W/G24q, CFT13W/2GX7,CFM13W/G24q, F14T8, F14T12, F15T8, F15T12, F17T8, F18T8, CFTR18W/GX24,CFQ18W/G24q, FT18W/2G11, F20T8, F20T12, or FC8T9(22W)G10q lampClass A Sound RatingEnd of Lamp Life ProtectionMore efficient compared to standard magnetic ballastsLead wires do not interfere with mounting holes
Contains No PCBs
Eliminates strobing
Thermal potting
Metal enclosure
Rapid Start
Features & Benefits
IG1320ELSXH
0.19"(5mm) 0.19"
(5mm)
3.095" (79mm)
1.2"
(30m
m)
1.87
"(4
7mm
)
• Operating Voltage: 120 VAC ± 10%• Frequency: 50/60Hz• Protection: Class P Inherent Thermal Protection
• Regulatory Approvals: UL, CUL Listed• Over Current: Fuse• Min. Starting Temp: 0˚F (-17.78˚C)
• Max. Case Temp: 194˚F (90˚C)• FCC, 47 CFR, Part 18 Consumer Limits• Type 1 Outdoor, Normal Power Factor
SPECIFICATIONS• Operating Voltage: 120 VAC• Frequency: 50/60Hz• Protection: Class P Inherent Thermal Protection
• Regulatory Approvals: UL, CUL Listed• Over Current: Fuse• Min. Starting Temp: 0˚F (-17.78˚C)
• Max. Case Temp: 158˚F (75˚C)• FCC, 47 CFR, Part 18 Consumer Limits• Type 1 Outdoor, Normal Power Factor
• One or Two Lamp• Multi-Watt• Energy Saving
Wide lamp versatility, suitable for one or two F14T8, F15T8, F17T8,F21T8, F25T8, F28T8, F30T8 or F32T8 lampsClass A Sound RatingMore efficient compared to standard magnetic ballasts
Contains No PCBsEliminates strobingThermal pottingMetal enclosureInstant Start
Features & Benefits
IG21432ELT8
1.22”
(31m
m)
1.77”
(45m
m)
9.57” (243.1mm)
black/white-24” red-50” blue-34”Weight: 20 oz. Case Quantity: 30pcs Case Weight: 38 lbs Standard Lead Length:
Inter-Global warrants that its fluorescent ballast shall be free from defects in material and workmanship and will be of the designated kind and quality for the
assigned period listed below from the date of manufacture.
Inter-Global makes no warranty whatsoever with respect to any ballast not installed and operated in accordance with the current edition of the National Electrical
Code, the standards of safety of Underwriters Laboratories, the standards of the American National Standards Institute and specific instructions provided by Inter-
Global for installation and operation of the ballast.
If it appears within the said warranty period that any Inter-Global ballast does not meet the warranty specified above, the purchaser must give written notice of
their warranty claim and return the ballast, at the purchaser's expense to Inter-Global or an authorized sales representative in purchaser's geographic area.. Within
sixty (60) days of receipt, Inter-Global shall at its expense and option correct any defects by either repairing or replacing the defective part(s) or the ballast. This war-
ranty is not applicable to any ballast subjected to abnormal stresses, operating conditions and operating conditions including lamp mismatch applications.
TEMPERATURE ON BALLAST CASE SHOULD NOT EXCEED THE MAXIMUM TEMPERATURE SPECIFIED ABOVE . Inter-Global cannot be responsible for
non Inter-Global equipment which is attached to or used in conjunction with the ballast and all such equipment is expressly excluded from Inter-Global's warranty.
The foregoing warranty is exclusive of all other statutory written or oral warranties and no other warranties of any kind, statutory or otherwise, are given or here-
in expressed. INTER-GLOBAL HEREBY DISCLAIMS ANY IMPLIED STATUTORY WARRANTY OR IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE.
Under no circumstances whether as a result of breach of contract, breach of warranty, tort strict liability or otherwise, will Inter-Global or any distributor or sales
representative be liable for consequential, incidental, special or exemplary damages, including but not limited to loss of profits, loss of use or damage to any property
or equipment, cost of capital, cost of substitutes, products facilities or services, down time cost or claims of purchaser's customers.
The Liability of Inter-Global or any distributor or sales representative on all claims of any kind for any loss or damage arising out of, resulting from or concerning
any aspect of this limited warranty, from the ballast furnished, shall not exceed the price of the specific ballast which gives rise to the claims.
REPAIR OR REPLACEMENT FOR BALLAST UNDER WARRANTY
Step 1 Contact Inter-Global within 30 days of discovery to explain the nature of the defect:
BY MAIL - Inter-Global Warranties, 6333 Etzel Avenue, St. Louis, MO 63133-1998
Step 2 You may be instructed to send some or all of the units back for evaluation. In some cases a complete lighting fixture will be required for testing. You will
be given a Return Authorization (RGA) Number. This number must appear on all cartons, packaging slips, debit memos and other correspondence. No
merchandise will be accepted without a valid RGA number marking the shipment. The ballast must be returned freight prepaid-COLLECT
SHIPMENTS WILL BE REFUSED.
RETURN MERCHANDISE TO 6333 ETZEL AVE., ST. LOUIS, MO 63133-1998
Step 3 The returned ballast will be evaluated by Inter-Global to determine if it is covered under the Limited Warranty.
BALLAST UNDER WARRANTY - When all of the following conditions exist, the returned ballast will be considered under warranty
and will be repaired or replaced at the option of Inter-Global.
1. The ballast was manufactured less than the specific warranty period earlier than the date of return.
2. It is determined by Inter-Global that the ballast was installed and operated in accordance with the current edition of the National Electrical
Code, the standards for safety of Underwriter's Laboratories, Inc. the standards of the American National Standards Institute and the specific
inst ructions provided by Inter-Global for installation and operation of the ballast.
3. The ballast does not operate according to Inter-Global specifications, due to defects in material or workmanship.
4. The ballast manufacturing date code has not been altered or is not missing (DATE CODE - Each ballast is marked with a date code
in the form of a sticker or stamped into the case depending on the type of unit). The first two digits represent the year, and the next two digits represent
the month of the year of manufacture.
5. The ballast was not damaged due to physical abuse and was returned in adequate packaging to prevent damage to the ballast.
BALLAST NOT UNDER WARRANTY - Any ballast determined by Inter-Global not to be under warranty will be returned to the
customer (freight paid by customer), or destroyed, at the customer's option.
Part Number Warranted for this Period
IG9O 3 Years (maximum case temp. of 90°C)
IG9OP 3 Years (maximum case temp. of 90°C)
IG9CP 3 Years (maximum case temp. of 90°C)
PS2/809ML-120 3 Years (maximum case temp. of 75°C)
IG13OP 3 Years (maximum case temp. of 90°C)
IG13CPWH 3 Years (maximum case temp. of 90°C)
PS2/813ML-120 3 Years (maximum case temp. of 75°C)
PS213ML-120 3 Years (maximum case temp. of 75°C)
IG13ML-120 3 Years (maximum case temp. of 90°C)
IG13MH-120 3 Years (maximum case temp. of 90°C)
IG15-20 3 Years (maximum case temp. of 90°C)
IG28OP 3 Years (maximum case temp. of 90°C)
IG220N-120P 3 Years (maximum case temp. of 90°C)
BALLAST LIMITED WARRANTY
Part Number Warranted for this Period
IG5-13ELS 2 Years (maximum case temp. of 75°C)
IG13-20EL 2 Years (maximum case temp. of 75°C)
IG13-20EL/T9 2 Years (maximum case temp. of 75°C)
IG13-20ELSX 2 Years (maximum case temp. of 75°C)
IG13-20ELSXH 2 Years (maximum case temp. of 90°C)
IG130ELSX 2 Years (maximum case temp. of 75°C)
IG25-32ELSX 2 Years (maximum case temp. of 90°C)
IG213-20ELSX 2 Years (maximum case temp. of 90°C)
IG226-32ELSX 2 Years (maximum case temp. of 90°C)
IG230ELSX 2 Years (maximum case temp. of 75°C)
PS2/832EL-120 2 Years (maximum case temp. of 75°C)