Top Banner

Click here to load reader

Lomb 14266 intelli flex

Jan 16, 2017

ReportDownload

salutaria

  • With its unique innovative technologies and proven best-in-class design, the Aorfix Endovascular Stent Graft with IntelliFlex Low Profile (LP) Delivery System brings exceptional conformability to the widest range of patient anatomies.

    The IntelliFlex LP Delivery System has been optimized for improved access, enhanced procedural control, and precise placement of the Aorfix Stent Graft.

    Low-profile 18F design to treat patients with narrow-access vessels

    Integrated sheath for fewer exchanges and reduced vessel trauma

    Intuitive deployment for ease of use

    New Y-Mec Deployment System for controlled and precise placement

    LOMB-14266 IntelliFLEX LP Sales Sheet r31.indd 6/30/16

    4/4 3

    8.5 x 11" .125"

    NEW IntelliFlex

    Low Profile Delivery SystemControlled Delivery, Predictable Placement.

  • The IntelliFlex Low Profile Delivery System is CE marked. The IntelliFlex Low Profile Delivery System is not available for distribution in the USA.

    2016 Lombard Medical, Inc. The Lombard Medical logo, the Aorfix Endovascular Stent Graft logo, the IntelliFlex Low Profile Delivery System logo, the IntelliFlex name, the Aorfix name, and the Y-Mec name are trademarks or registered trademarks of Lombard Medical, Inc. PN03857

    Improved Access Intuitive Delivery

    With its reduced profile, optimized ease of use, and ergonomic design, the new IntelliFlex Low Profile (LP) Delivery System brings control and confidence to AAA procedures.

    United Kingdom Lombard Medical, Inc.Lombard Medical House4 Trident ParkDidcot, OX11 7HJ | Tel: +44 (0) 1235 750800E-mail: [email protected]

    Corporate OfficeLombard Medical, Inc.Irvine, CA | Tel: 866 790 1447E-mail: [email protected]medical.com

    LombardMedical.com

    1. Shorter, flexible tip for agile maneuvering

    2. Smooth tip-to-sheath transition enhances delivery

    1 3

    24

    3. Double-braided kink-resistent sheath for improved trackability

    4. Easy-to-use handle with numbered steps and directional arrows

    Innovative Y-Mec Deployment System provides active expansion of proximal graft for confident placement

    Integrated 18F SheathNEW Y-Mec Deployment System

    Fewer exchanges

    Decreases procedure time

    Eliminates the need for additional sheaths, reducing procedure costs

    Optimal seal, from hemostatic valve

    Matching dilator included

Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.