Top Banner
Little Black Box Plus K71 by Atomic.dave [email protected] This is a one of a kind custom hand-made Geiger Counter built by Atomic.Dave. It is based on a kit de- signed by John Giametti (username: Brohogan) All information for this kit is available at the developer’s web- site. As I have said before, this is more of a kit for someone who knows a little bit about electronics but doesn’t have the time or patience to build it, or would rather someone else do all the dirty work. Having been built by me, of course there will be some imperfections, although as minimal as possible. This unit is a slimmed down version of the other units I build running the version 10.1 of the DIY software. It has only three switches. Two of them are three position slides, and the middle is a momentary switch used for 2 reasons explained in detail below. DIY GEIGER COUNTER DEVELOPERS WEBSITE: http://www.sites.google.com/site/diygeigercounter/ OPERATION POWER SWITCH Three positions- Middle is OFF, Up is ON with LCD backlight on, and down is ON with backlight OFF. As soon as you power on, On Display you see the words: Atomic.Dave K71 LND712 v10.1 This customized first welcome window can easily be changed if you want, by doing a little programming in Arduino which is explained further in the ARDUINO SETTINGS section below. For detailed instructions, please refer to the DIY (link above) and go to the SOFTWARE section. In this first window, K71 refers to the 71st DIY kit built by me, LND712 refers to the tube, and v10.1 is the DIY software version the unit is running. The second window will show something like this: 100 CPM=1 uSv/hr Running at 5.07V The first line refers to the conversion rate of CPM to uSv/hr for your LND712 tube (100) this can be changed in the program sketch, with Arduino, but it is set so no change is necessary. The second line refers to the current voltage that your system is running at. This is a 5 volt system. The Nine volt battery are boosted down to 5v with a pololu Step up/down booster. Everytime you start up your GC (geiger counter) it will show you this so you will always know your current voltage. After that, the third window will look something like this: CPM 48 || ||| ||| || uSv/hr 0.13 On the first line is the current CPM and to the right of it is a graphical simulation of by the second CPM representation. On the second line is the converted uSv/hr. LEDS Right away, you will hear the beeping of the piezo as your LND712 GM tube picks up radiation events. There are 2 LEDs. The BLUE is for radiation events and coincides with the beeping piezo which can be muted with the SOUND switch on the right. Middle position is MUTED alarm and event click. Up is Event click only, and the Alarm only will light up RED on the LED. Bottom position, is to turn on the alarm and event beep as well as the RED Led when the alarm threshold is reached. More on that below. GREEN MENU MODE BUTTON 1. When you first turn on the unit, the third window will prompt you to set the Alarm. If you have not set it yet, it will say Alarm OFF. However if you hold the mode button down the alarm set amount will climb in incre- ments of 10 cpm till it gets to 100, then it climbs in sets of 50 until it reaches a max of 600 cpm, until you let go, and once you let go, that is what the alarm threshold will be until you reset it. As long as you don't reset it, that is the amount it will remain at. I have preset the alarm to 150 CPM. 2. The first display that comes up is the current CPM and below it is the level of uSv/hr. To the right of the CPM is a bar graphic representative of the level of Radiation occuring by the second. The CPM and uSv por- tion is updated every 4 seconds. 3. Press the mode button and a new display will come up. It is like a stopwatch and as soon as you press it for the first time it will start the timer process where it will give you average counts in a 1 minute and 10 minute period. Until it reaches 1 minute or 10 minutes it will show current total counts. After it reaches those points it will show the uSv conversion on the right column. 4. Press the mode button again and it will go back to the first menu. 3.5MM MULTIPORT At the left side middle is the output multi-port used for Safecast (with the included cable 3 to 4 band cable), and for Geiger Graph and RAD OSX (with the optional USB/FTDI cable) Just plug in the cable in with the 3 conductor plug, and the 4 conductor into your iphone or ipad. Or plug the optional FTDI 3.5mm to USB cable into the port, and into a USB on your mac or PC, then follow instructions to run those programs. It also serves as an mono audio output for silent listening with headphones. I have also supplied you with a audio cable that you can use to plug your unit into your mac or pc’s mic input, then you can run audio based geiger counter data logging software such as RAD OSX. However the prefered method is to use the optional cable that is listed below. Google FTDI/TTL-232R-3V3-AJ.
7

K71_712_MAN

Sep 06, 2015

Download

Documents

David Kasai

Little Black Box Plus Geiger Counter with internal LND712 GM tube
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • Li ttle Black Box PlusK71 by Atomic.dave [email protected]

    This is a one of a kind custom hand-made Geiger Counter built by Atomic.Dave. It is based on a kit de-signed by John Giametti (username: Brohogan) All information for this kit is available at the developers web-site. As I have said before, this is more of a kit for someone who knows a little bit about electronics butdoesnt have the time or patience to build it, or would rather someone else do all the dirty work. Having beenbuilt by me, of course there will be some imperfections, although as minimal as possible. This unit is aslimmed down version of the other units I build running the version 10.1 of the DIY software. It has only threeswitches. Two of them are three position slides, and the middle is a momentary switch used for 2 reasonsexplained in detail below.

    DIY GEIGER COUNTER DEVELOPERS WEBSITE:http://www.sites.google.com/site/diygeigercounter/

    OPERATIONPOWER SWITCH Three positions- Middle is OFF, Up is ON with LCD backlight on, and down is ON withbacklight OFF. As soon as you power on, On Display you see the words:

    Atomic.Dave K71 LND712 v10.1

    This customized first welcome window can easily be changed if you want, by doing a little programmingin Arduino which is explained further in the ARDUINO SETTINGS section below. For detailed instructions,please refer to the DIY (link above) and go to the SOFTWARE section. In this first window, K71 refers to the71st DIY kit built by me, LND712 refers to the tube, and v10.1 is the DIY software version the unit is running.

    The second window will show something like this:100 CPM=1 uSv/hr Running at 5.07V

    The first line refers to the conversion rate of CPM to uSv/hr for your LND712 tube (100) this can bechanged in the program sketch, with Arduino, but it is set so no change is necessary. The second line refersto the current voltage that your system is running at. This is a 5 volt system. The Nine volt battery areboosted down to 5v with a pololu Step up/down booster. Everytime you start up your GC (geiger counter) itwill show you this so you will always know your current voltage.

    After that, the third window will look something like this:CPM 48 || ||| ||| ||uSv/hr 0.13

    On the first line is the current CPM and to the right of it is a graphical simulation of by the second CPMrepresentation. On the second line is the converted uSv/hr.

    LEDSRight away, you will hear the beeping of the piezo as your LND712 GM tube picks up radiation events. Thereare 2 LEDs. The BLUE is for radiation events and coincides with the beeping piezo which can be muted withthe SOUND switch on the right. Middle position is MUTED alarm and event click. Up is Event click only, andthe Alarm only will light up RED on the LED. Bottom position, is to turn on the alarm and event beep as wellas the RED Led when the alarm threshold is reached. More on that below.

    GREEN MENU MODE BUTTON1. When you first turn on the unit, the third window will prompt you to set the Alarm. If you have not set it

    yet, it will say Alarm OFF. However if you hold the mode button down the alarm set amount will climb in incre-ments of 10 cpm till it gets to 100, then it climbs in sets of 50 until it reaches a max of 600 cpm, until you letgo, and once you let go, that is what the alarm threshold will be until you reset it. As long as you don't resetit, that is the amount it will remain at. I have preset the alarm to 150 CPM.

    2. The first display that comes up is the current CPM and below it is the level of uSv/hr. To the right of theCPM is a bar graphic representative of the level of Radiation occuring by the second. The CPM and uSv por-tion is updated every 4 seconds.

    3. Press the mode button and a new display will come up. It is like a stopwatch and as soon as youpress it for the first time it will start the timer process where it will give you average counts in a 1 minute and10 minute period. Until it reaches 1 minute or 10 minutes it will show current total counts. After it reachesthose points it will show the uSv conversion on the right column.

    4. Press the mode button again and it will go back to the first menu.

    3.5MM MULTIPORTAt the left side middle is the output multi-port used for Safecast (with the included cable 3 to 4 band cable),and for Geiger Graph and RAD OSX (with the optional USB/FTDI cable) Just plug in the cable in with the 3conductor plug, and the 4 conductor into your iphone or ipad. Or plug the optional FTDI 3.5mm to USB cableinto the port, and into a USB on your mac or PC, then follow instructions to run those programs. It alsoserves as an mono audio output for silent listening with headphones. I have also supplied you with a audiocable that you can use to plug your unit into your mac or pcs mic input, then you can run audio based geigercounter data logging software such as RAD OSX. However the prefered method is to use the optional cablethat is listed below. Google FTDI/TTL-232R-3V3-AJ.

  • ARDUINO Software and Serial-USB connection information:ON the cd you will find the FTDI driver and Arduino program version 1. Install both and restart your mac.Copy the Geiger Sketch folder to the same folder as your Arduino program is and remember where that is asthat will be where you go to save your sketch everytime you make a change to it. There will also be a Libraryfolder that will also need to be in the same folder. Just remember that the folder has to be the same exactname as the sketch name is. And also within Arduino, you will have to go to preferences and show Arduinowhere your default sketch folder is.

    ARDUINO SETTINGS:1. Open Arduino2. Open the saved sketch .ino file, connect your Geiger counter to the USB with power switch off.3. Verify the file by clicking the little check mark icon.4. Click TOOLS, and Select Board type as Arduino UNO, and select serial port as the top tty choice.5. Click Serial Monitor (top right looking glass icon). Set Baud rate to 9600 and you should see the CPM, uSvand geiger counter voltage data coming up once per minute.For more info go to website under Software section on the DIY geiger counter website. Or go to Arduino.cc

    Safecast SUGGESTED SETTINGS: (You will probably have to play with it to get it just right- and I used touse Geiger Bot, but it seems that Safecast is more stable and works everytime.)https://itunes.apple.com/us/app/safecast/id571167450?mt=8

    RAD OSX free data logging for macs: (although you can use the included 3.5mm male to male 3 conduc-tor to 3 conductor audio cable from the multiport to your PC or Macs MIC input, it works best with theFTDI/TTL USB cable below)http://www.blackcatsystems.com/GM/download.html

    GEIGER GRAPH FOR PC NETWORKS: http://www.imagesco.com/geiger/geiger-graph.html(cost is around $60. Use the Optional FTDI 3.5mm to USB cable) This is a PC only software. To purchasethe optional cable go to: www.mouser.com, and do a search for: FTDI/TTL-232R-3V3-AJ

    HARDWARE1. DIY Geiger counter kit V4.0 by Brohogan

    http://www.sites.google.com/site/diygeigercounter/2. LND 712 Geiger Muller Tube3. Power System by Pololu

    A. You can power the Geiger in a couple different ways 1. With 9 volt batteries2. With USB cable plugged into data port on RIGHT side of geiger then plugged into:

    a. Computer or laptop USBb. 5V USB Wall charger block (included)c. Standard 5v USB Cigarette adapter (not included)d. To power and operate the unit this way make sure POWER SWITCH IS IN OFF POSITION

    - Its ok to have switch the on for a little while, but DAMAGE MIGHT OCCUR if left this wayfor long periods- best bet is NOT to do this.

    e. For long usage of geiger counter (constant on for long periods) the preferred way to power itwould be to use the USB cable plugged in right FTDI port and power OFF. And i would alsosuggest turning on the backlight only if you need it to save power.

    POWER and OTHER SYSTEM ITEMS:A. Pololu Step Up/Step Down Voltage Regulator S7V7F5http://www.pololu.com/catalog/product/2119

    C. Sparkfun 5V FTDI Basic Breakouthttps://www.sparkfun.com/products/9716

    Select options Select Geiger Counter Select LND712 CS137 Adjust Conversion factor to your tube:

    123 for LND712175 for SBM-20

    360 for LND7317Select I/O Settings

    Auto Adjust OFF(you may need to play

    with this setting) RMS Window 1

    Delay Window 30Volume Thresh 20000

    Ultrafast Rates ON

  • LND-712 GEIGER MULLER TUBEInstalled inside this nicely planned out kit is a LND 712 which senses Alpha, Beta, Gamma and Xray. The tube is vented in front of the Mica win-dow for Alpha particles, and also the bottom of the kit has a vent for beta and gamma.

    http://www.lndinc.com/products/711/

    ENCLOSUREDimensions: Hammond Enclosures- 1593Y - 5.5" x 2.6" x 1.1" http://users.ece.utexas.edu/~valvano/EE345L/Labs/Fall2011/Hammond1593Y.pdf

    REPAIRS:I will be more than happy to do any maintenance or calibration, if you need at no charge except shipping.

    PACKAGE CONTENTS:In your package you will find: Geiger Counter, Lead Pig w/ Samples, (3) Cables: Geiger bot 3 to 4 conductor, Audio 3 to 3 conductor, Mini USB tostandard USB2 and wall charger , CD with software and documents, Manual, stickers, extra silicon feet, and extra faceplate labels. FREE Battery.

  • BALP

    HA

    s BETA s GAMM

    A s

    XR

    AY

    LND 712

    atomic.davethe little black box+plusRADIATION DETECTOR

    POWERLT ONOFF

    LT OFF

    SOUNDCLICKMUTE

    ALARM

    SELECTALARMSCALER

  • 1593

    YBK

    1593

    YGY

    1593

    QS

    100

    (Silv

    er)

    1593

    QS

    100B

    K (B

    lack

    )

    1593

    ATS

    50 (P

    kg 5

    0)15

    93AT

    S10

    0 (P

    kg 1

    00)

    1599

    CLI

    P (B

    lack

    )15

    99C

    LIP

    GY

    (Gre

    y)15

    93D

    IR10

    Cov

    er S

    crew

    s (P

    kg 1

    00)

    [#4

    x 3/

    4" s

    elf-t

    appi

    ng o

    val h

    ead

    (19.

    1mm

    )]

    P.C

    . Boa

    rd S

    crew

    s[#

    4 x

    1/4"

    sel

    f-tap

    ping

    (6.4

    mm

    )]

    Bel

    t or P

    ocke

    t Clip

    Infra

    red

    Pan

    els

    (Pkg

    10)

    1593

    Y En

    clos

    ure

    AC

    CES

    SO

    RIE

    S

    Bla

    ck E

    nclo

    sure

    Gre

    y E

    nclo

    sure

    NO

    TEE

    nclo

    sure

    mol

    ded

    from

    GP

    AB

    S (U

    L94-

    HB

    ) pla

    stic

    .P

    urch

    ased

    ass

    embl

    y in

    clud

    es to

    p an

    d bo

    ttom

    cov

    er, f

    ront

    pan

    el

    (pla

    stic

    ), ba

    ttery

    doo

    r and

    4 c

    over

    scr

    ews.

    PA

    RT

    NU

    MB

    ER

    S

    1 1

    2 2

    AA

    BB

    B BA A

    40.5

    0[1

    .594

    ]31

    .00

    [1.2

    20]

    96.8

    9[3

    .815

    ]14.

    58[.5

    74]

    14.6

    1[.5

    75]

    28.0

    0[1

    .102

    ]

    57.2

    3[2

    .253

    ]

    5.66

    [.223

    ]

    6.73

    [.265

    ]

    R3.

    26[.1

    28]

    32.6

    4[1

    .285

    ]6.

    52[.2

    57]

    6.73

    [.265

    ]

    3.20

    [.126

    ] x

    6

    SEC

    TIO

    N A

    -A(S

    ide

    View

    Insi

    de A

    ssem

    bly)

    Han

    d H

    eld

    Inst

    rum

    ent (

    1593

    Y)

    End

    View

    of A

    ssem

    bly

    SEC

    TIO

    N B

    -B(In

    side

    of B

    otto

    m C

    over

    )

    Max

    imum

    P.C

    . Boa

    rd S

    ize

    Fron

    t/Rea

    r Pan

    el(D

    ashe

    d Li

    ne In

    dica

    tes

    View

    ing

    Are

    a)

    57.1

    9[2

    .252

    ](V

    iew

    ing

    Are

    a)

    20.9

    0[.8

    23]

    (Vie

    win

    g A

    rea)

    22.5

    0[.8

    86]

    58.8

    0[2

    .315

    ]

    1.70

    [.067

    ]

    28.0

    0[1

    .102

    ]

    1.57

    [.062

    ](P

    CB

    dis

    t fro

    m in

    ner w

    all)

    .50

    [.020

    ](P

    CB

    dis

    t fro

    m

    end

    pane

    l)

    60.3

    7[2

    .377

    ](In

    ner B

    ox W

    idth

    )

    132.

    89[5

    .232

    ](In

    ner B

    ox L

    engt

    h)

    Bot

    tom

    Cov

    er

    Fron

    t Pan

    el

    P.C

    . Boa

    rd A

    ligne

    d on

    Bos

    ses

    Top

    View

    of A

    ssem

    bly

    Det

    ail V

    iew

    of P

    CB

    Bos

    s(L

    ocat

    ed o

    n To

    p an

    d B

    otto

    m C

    over

    )

    140.

    00[5

    .512

    ]

    66.0

    0[2

    .598

    ]

    5.60

    [.220

    ]

    (Top

    Ass

    em B

    oss

    )

    5.60

    [.220

    ]

    (Bot

    tom

    Ass

    em B

    oss

    )

    P.C

    . Boa

    rd

    21.9

    0[.8

    62]

    (Inne

    r Box

    Hei

    ght)4

    .90

    [.193

    ]

    4.50

    [.177

    ]

    50.3

    0[1

    .980

    ]

    1.00

    [.039

    ](In

    lay

    Dep

    th)

    Bot

    tom

    Cov

    erFr

    ont P

    anel

    P.C

    . Boa

    rd(N

    ot S

    uppl

    ied)

    1593

    Y

    Enc

    losu

    res

    can

    be F

    acto

    ry M

    odifi

    ed (

    Mill

    ing,

    Dril

    ling,

    Prin

    ting

    etc.

    )S

    olid

    mod

    els

    of th

    is e

    nclo

    sure

    ava

    ilabl

    e in

    STE

    P o

    r IG

    ES

    .C

    onta

    ct F

    acto

    ry

    m

    jm@

    ham

    mon

    dmfg

    .com

    55.0

    0[2

    .165

    ](In

    lay

    Wid

    th)

    128.

    50[5

    .059

    ](In

    lay

    Leng

    th)

  • 89

    7

    6

    4

    3

    2

    5

    +

    +

    14

    17

    18

    19

    16

    15

    12

    12

    34

    56

    1 3 5

    +_

    EVEN

    TLE

    D

    ALA

    RM LED

    In

    AB

    Out

    2 4 6

    POWER

    LT O

    NO

    FFLT

    OFF

    SELECT

    ALAR

    MSC

    ALERB

    SOUN

    D

    CLIC

    KM

    UTE

    ALAR

    M

    12

    10

    11

    5V U

    p/D

    own

    BOO

    ST

    ALA

    RMPI

    EZO

    FTD

    I

    1K O

    HM

    RESI

    STO

    R

    56K

    OH

    MRE

    SIST

    OR

    3.5m

    mSo

    cket

    MU

    LTI-S

    OFT

    WA

    REO

    UTP

    UT

    PORT

    .1 u

    F Ca

    p

    .1 u

    F Ca

    p

    270

    OH

    MRE

    SIST

    OR

    300

    OH

    MRE

    SIST

    OR

    13

    1N41

    48di

    ode

    to 5

    V

    New

    Hav

    enA

    dap

    ter b

    oard

    MD

    fly 2

    x 1

    6 m

    ini L

    CD

    10K

    Pot

    +

    24

    68

    1012

    1416

    13

    57

    911

    13 1

    5

    to g

    roun

    d

    2345678 9 10 11 12 13

    +