Installing the Cisco ONS 15216 FBG DCU This document explains how to install the Cisco ONS 15216 fiber Bragg grating dispersion compensation unit (FBG DCU). In this document, the terms "Cisco ONS 15216 FBG DCU" and "FBG DCU" have been used interchangeably. Note Overview of the Cisco ONS 15216 FBG DCU , page 1 Safety Information, page 3 Installing the FBG DCU in the Chassis, page 4 Uninstalling the FBG DCU , page 12 Cleaning and Maintaining Fiber-Optic Connectors, page 13 FBG DCU Technical Specifications, page 15 Additional References, page 17 Trademark Notice, page 17 Obtaining Documentation and Submitting a Service Request, page 18 Overview of the Cisco ONS 15216 FBG DCU A DCU is placed in an optical network when the accumulated chromatic dispersion exceeds the maximum allowed dispersion tolerance. The DCU compensates for chromatic dispersion generated in the optical fiber, thus avoiding the need of dropping and regenerating the degraded optical signal. There are different types of DCUs and the fiber Bragg grating dispersion compensation unit is one of them. In an FBG DCU, the dispersion compensation is achieved by using a short segment of optical fiber having periodic variation in its refractive index. Installing the Cisco ONS 15216 FBG DCU 78-20751-01 1
18

Installing the Cisco ONS 15216 FBG DCU€¦ · Installing the FBG DCU Module in the DCU Chassis Procedure Step 1 AligntheFBGDCUmodulewiththeopeningonthefront-faceoftheDCUchassis.

Oct 13, 2018

Download

Documents

buithien
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Installing the Cisco ONS 15216 FBG DCU€¦ · Installing the FBG DCU Module in the DCU Chassis Procedure Step 1 AligntheFBGDCUmodulewiththeopeningonthefront-faceoftheDCUchassis.

Installing the Cisco ONS 15216 FBG DCU

This document explains how to install the Cisco ONS 15216 fiber Bragg grating dispersion compensationunit (FBG DCU).

In this document, the terms "Cisco ONS 15216 FBG DCU" and "FBG DCU" have been usedinterchangeably.

Note

• Overview of the Cisco ONS 15216 FBG DCU , page 1

• Safety Information, page 3

• Installing the FBG DCU in the Chassis, page 4

• Uninstalling the FBG DCU , page 12

• Cleaning and Maintaining Fiber-Optic Connectors, page 13

• FBG DCU Technical Specifications, page 15

• Additional References, page 17

• Trademark Notice, page 17

• Obtaining Documentation and Submitting a Service Request, page 18

Overview of the Cisco ONS 15216 FBG DCUA DCU is placed in an optical network when the accumulated chromatic dispersion exceeds the maximumallowed dispersion tolerance. The DCU compensates for chromatic dispersion generated in the optical fiber,thus avoiding the need of dropping and regenerating the degraded optical signal. There are different types ofDCUs and the fiber Bragg grating dispersion compensation unit is one of them. In an FBGDCU, the dispersioncompensation is achieved by using a short segment of optical fiber having periodic variation in its refractiveindex.

Installing the Cisco ONS 15216 FBG DCU 78-20751-01 1

Page 2: Installing the Cisco ONS 15216 FBG DCU€¦ · Installing the FBG DCU Module in the DCU Chassis Procedure Step 1 AligntheFBGDCUmodulewiththeopeningonthefront-faceoftheDCUchassis.

Product DescriptionThe Cisco ONS 15216 FBG DCU is a low latency dispersion compensation unit (DCU) that uses the FiberBragg Grating (FBG) technology. It has a very low insertion loss when compared to a standard DCU. TheCisco ONS 15216 FBG DCU complements the Cisco ONS 15216 platform and can interoperate with theONS 15454, ONS 155xx, and ONS 15600 products.

There are multiple FBG DCU modules, each designed to operate at a specific compensation level. Individualmodules can be cascaded to provide higher level of compensation. The Cisco ONS 15216 FBGDCUmodulesoperate in the C-band within the wavelength range of 1528.77 nm to 1566.31 nm at a 100 GHz grid spacing.

The Cisco ONS 15216 FBGDCU should be used only in networks carrying traffic at 100 GHz grid spacing.Note

The FBG DCU consists of the following components:

• FBGDCUmodule—This unit performs the dispersion compensation process. It consists of optical fibergrating, optical connectors, and optical mating adapters for optical input and output connections. Theoptical mating adapter has a shutter that provides protection from laser radiation. The shutter also protectsagainst dirt and dust, which can cause equipment failure.

The FBG DCU module has a USB port, which is used only when the FBG DCU is placed in anONS 15454 M6 shelf. The USB connection between the FBG DCU module and the ONS 15454 M6shelf is used for retrieving inventory data.

The FBG DCU module is a passive unit and therefore, does not need any electrical power supply.

The various parts of the FBG DCU module are shown in the following figure.

Figure 1: Parts of the FBG DCU Module

Pull handle2Cable holder clip1

USB port4USB cable holder3

Optical mating adapter6Locking latch5

Installing the Cisco ONS 15216 FBG DCU2 78-20751-01

Installing the Cisco ONS 15216 FBG DCUProduct Description

Page 3: Installing the Cisco ONS 15216 FBG DCU€¦ · Installing the FBG DCU Module in the DCU Chassis Procedure Step 1 AligntheFBGDCUmodulewiththeopeningonthefront-faceoftheDCUchassis.

For various Cisco ONS 15216 FBG DCU product IDs (PIDs) and the corresponding dispersioncompensation values, see Optical Specifications, on page 15.

• DCU chassis (Product ID: 15216-DCU-SA=)—This is a passive mechanical chassis that is used to housethe FBG DCU modules. Inside the chassis, two independent FBG DCU modules are placed, as shownin the following figure. TheDCU chassis can bemounted on a 19-inch (482.6-mm) or 23-inch (584.2-mm)rack using suitable brackets. It occupies one rack-unit (RU) space.

Figure 2: DCU Chassis

Second FBG DCU module2First FBG DCU module1

FeaturesThe Cisco ONS 15216 FBG DCU has the following features:

• Latency lower than 25 ns.

• Low insertion loss values (4.5 dB maximum).

• Optical connectivity, using the LC-UPC connector.

• USB connectivity with Cisco ONS 15454 M6 shelf for retrieving inventory data.

• Installation supported in standard Cisco ONS 15216 DCU SA chassis.

Safety InformationBefore you install, operate, or service this product, you must read the Regulatory Compliance and SafetyInformation for Cisco Optical Transport Products document for important safety information and warningtranslations.

This product is compliant with the GR 1089, UL60950 /CSA 22.2 No. 60950-00, and IEC 60950 standards.

Installing the Cisco ONS 15216 FBG DCU 78-20751-01 3

Installing the Cisco ONS 15216 FBG DCUFeatures

Page 4: Installing the Cisco ONS 15216 FBG DCU€¦ · Installing the FBG DCU Module in the DCU Chassis Procedure Step 1 AligntheFBGDCUmodulewiththeopeningonthefront-faceoftheDCUchassis.

Laser Radiation Emission RestrictionsThe Class 1M Laser safety and warning label is affixed to this product and indicates that the product shouldnever be used or installed in an optical network with emissions higher than Class 1M.

Class 1M laser radiation when open. Do not view directly with optical instruments. Statement 281Warning

Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into beamsor view directly with optical instruments. Statement 1051

Warning

Electrical SafetyThis product is optically and electrically passive and requires no electrical connections. No electrostaticdischarge (ESD) or other electrical safety considerations apply.

Installing the FBG DCU in the ChassisInstall the FBG DCU by sequentially following these procedures.

Unpacking and Verifying the Unit

Procedure

Step 1 After receiving the FBG DCU package, unpack and verify that it includes the following:

• FBG DCU module

• Job aid card

• Warranty sheet

• Packing slip

Step 2 Compare the equipment received with the equipment list that the customer service representative provided.If there are any discrepancies, notify the Customer Service Center.

Step 3 Visually check all components for external damage. Look out for the following damages:

• Bent or broken cable holder clip

• Dent on the outer case

• Damaged USB connector

• Broken shutters for optical mating adapters

Installing the Cisco ONS 15216 FBG DCU4 78-20751-01

Installing the Cisco ONS 15216 FBG DCULaser Radiation Emission Restrictions

Page 5: Installing the Cisco ONS 15216 FBG DCU€¦ · Installing the FBG DCU Module in the DCU Chassis Procedure Step 1 AligntheFBGDCUmodulewiththeopeningonthefront-faceoftheDCUchassis.

• Jammed or broken locking latch

• Scratched paint

• Missed labels

Step 4 Immediately report any shipping damage to the customer service representative. Keep the following informationhandy while contacting the customer service.

• Invoice number of shipper (see packing slip)

• Model and serial number of the damaged unit (printed on the front panel)

• Description of damage

• Effect of damage on the installation

• Packing slip

Installing the DCU Chassis on the Rack

The DCU chassis should be procured separately; product ID: 15216-DCU-SA=.Note

Installing the Cisco ONS 15216 FBG DCU 78-20751-01 5

Installing the Cisco ONS 15216 FBG DCUInstalling the DCU Chassis on the Rack

Page 6: Installing the Cisco ONS 15216 FBG DCU€¦ · Installing the FBG DCU Module in the DCU Chassis Procedure Step 1 AligntheFBGDCUmodulewiththeopeningonthefront-faceoftheDCUchassis.

Procedure

Step 1 Screw the mounting brackets onto the DCU chassis, as shown in the following figure.

Figure 3: Installing Mounting Brackets on the DCU chassis

Mounting bracket2Bracket screws1

Installing the Cisco ONS 15216 FBG DCU6 78-20751-01

Installing the Cisco ONS 15216 FBG DCUInstalling the DCU Chassis on the Rack

Page 7: Installing the Cisco ONS 15216 FBG DCU€¦ · Installing the FBG DCU Module in the DCU Chassis Procedure Step 1 AligntheFBGDCUmodulewiththeopeningonthefront-faceoftheDCUchassis.

Step 2 Position the DCU chassis on the rack such that the rear face of the mounting bracket is flush against the frontface of rack.

Step 3 Align the mounting bracket screw holes with that of the rack.Step 4 Insert the rack mounting screws into the screw holes and tighten them, as shown in the following figure.

Figure 4: Mounting the DCU Chassis on the Rack

Mounting screws2DCU chassis1

Mounting bracket4Washer3

Rack5

Grounding the DCU Chassis

This equipment must be grounded. Never defeat the ground conductor or operate the equipment in theabsence of a suitably installed ground conductor. Contact the appropriate electrical inspection authorityor an electrician if you are uncertain that suitable grounding is available. Statement 1024

Warning

Installing the Cisco ONS 15216 FBG DCU 78-20751-01 7

Installing the Cisco ONS 15216 FBG DCUGrounding the DCU Chassis

Page 8: Installing the Cisco ONS 15216 FBG DCU€¦ · Installing the FBG DCU Module in the DCU Chassis Procedure Step 1 AligntheFBGDCUmodulewiththeopeningonthefront-faceoftheDCUchassis.

Procedure

Step 1 Crimp a #14 AWG ground cable to the ground lug.Step 2 Connect one end of the ground cable to the DCU chassis. The screw holes to fix the grounding lug is present

on the right side of the DCU chassis, as shown in the following figure.

Figure 5: Installing the Grounding Lug

Lug screws2Grounding lug1

Step 3 Terminate the other end of the ground strap either at the office ground point or the rack ground point.

Installing the Cisco ONS 15216 FBG DCU8 78-20751-01

Installing the Cisco ONS 15216 FBG DCUGrounding the DCU Chassis

Page 9: Installing the Cisco ONS 15216 FBG DCU€¦ · Installing the FBG DCU Module in the DCU Chassis Procedure Step 1 AligntheFBGDCUmodulewiththeopeningonthefront-faceoftheDCUchassis.

Installing the FBG DCU Module in the DCU Chassis

Procedure

Step 1 Align the FBG DCU module with the opening on the front-face of the DCU chassis.Step 2 Use both hands to push the module all the way into the chassis until the locking latch, present on the right

side of the module, clicks into place (see the following figure).

Figure 6: Installing the FBG DCU Module

Step 3 Repeat the above steps to insert the second FBG DCU module in the DCU chassis.

Installing and Routing Fiber-Optic Cables

Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into beamsor view directly with optical instruments. Statement 1051

Warning

Before You Begin

Visually inspect the fiber-optic cable to check its physical integrity.

Installing the Cisco ONS 15216 FBG DCU 78-20751-01 9

Installing the Cisco ONS 15216 FBG DCUInstalling the FBG DCU Module in the DCU Chassis

Page 10: Installing the Cisco ONS 15216 FBG DCU€¦ · Installing the FBG DCU Module in the DCU Chassis Procedure Step 1 AligntheFBGDCUmodulewiththeopeningonthefront-faceoftheDCUchassis.

Always clean all fiber connectors thoroughly before making the connection with the optical mating adapter.Very small dust particles can permanently damage the end of the mating fiber inside the FBG DCU module.For cleaning instructions see Cleaning and Maintaining Fiber-Optic Connectors, on page 13.

Procedure

Step 1 Lift the shutter of the optical mating adapter present on the front panel of the FBG DCU module.Step 2 Place the LC/UPC cable connector in front of the optical mating adapter and align the cable connector with

the adapter slot.Step 3 Gently push the cable connector into the adapter until you hear a click, which indicates that the latching system

is engaged.Step 4 Route the optical fiber cables through the cable holder clip.Step 5 If required, bundle and secure the fibers using velcro strips.

Installing and Routing the USB CablePerform this procedure only if the FBG DCU is placed in a Cisco ONS 15454 M6 shelf.

Installing the Cisco ONS 15216 FBG DCU10 78-20751-01

Installing the Cisco ONS 15216 FBG DCUInstalling and Routing the USB Cable

Page 11: Installing the Cisco ONS 15216 FBG DCU€¦ · Installing the FBG DCU Module in the DCU Chassis Procedure Step 1 AligntheFBGDCUmodulewiththeopeningonthefront-faceoftheDCUchassis.

Procedure

Step 1 Correctly align the USB connector with the USB port present on the front panel of the FBG DCU module.Step 2 Push the USB connector into the USB port.Step 3 Unscrew and remove the USB cable holder provided on the pull handle, as shown in the following figure.

Figure 7: Installing USB Cable Holder

USB cable holder2Screws1

Pull handle3

Step 4 Route the USB cable through the groove present on the cable holder.Step 5 Screw the USB cable holder in place to secure the USB cable.Step 6 Connect the other end of the USB cable to the Cisco ONS 15454 M6 shelf.

What to Do Next

Retrieval of inventory data from the FBG DCU module is performed using the USB connection. For detailsabout using USB connectivity, see the "Connecting Passive Modules to a ONS 15454 M2 or ONS 15454 M6Node" section and the "NTP-G319 Connect a Passive Module to the Cisco ONS 15454 M2 or Cisco ONS15454M6Node" task in the "Node Reference" chapter of theCisco ONS 15454 DWDMConfiguration Guide.

Installing the Cisco ONS 15216 FBG DCU 78-20751-01 11

Installing the Cisco ONS 15216 FBG DCUInstalling and Routing the USB Cable

Page 12: Installing the Cisco ONS 15216 FBG DCU€¦ · Installing the FBG DCU Module in the DCU Chassis Procedure Step 1 AligntheFBGDCUmodulewiththeopeningonthefront-faceoftheDCUchassis.

Uninstalling the FBG DCUIf the DCU unit is not functioning properly, it results in high insertion loss. When this insertion loss exceedsa threshold value, the DCU-LOSS-FAIL alarm is raised in CTC. For more information about theDCU-LOSS-FAIL alarm, see the Cisco ONS 15454 DWDM Troubleshooting Guide.

For the purpose of maintenance or replacement, you need to uninstall the FBGDCU by sequentially followingthese procedures.

Removing the FBG DCU Module from the DCU Chassis

Procedure

Step 1 Disconnect the optical and USB cables from the FBG DCU module.Step 2 Push the locking latch to the left and hold it. The locking latch is located on the right-side of the FBG DCU

module, as shown in the following figure.If the locking latch is jammed, apply more pressure to release it.

Step 3 Use the pull handle to pull the module until the locking latch comes out free, as shown in the following figure.The pull handle is provided on the center of the front panel.

Figure 8: Removing the FBG DCU Module from the DCU Chassis

Pull the handle2Push the locking latch1

Installing the Cisco ONS 15216 FBG DCU12 78-20751-01

Installing the Cisco ONS 15216 FBG DCUUninstalling the FBG DCU

Page 13: Installing the Cisco ONS 15216 FBG DCU€¦ · Installing the FBG DCU Module in the DCU Chassis Procedure Step 1 AligntheFBGDCUmodulewiththeopeningonthefront-faceoftheDCUchassis.

Step 4 Release the locking latch.Step 5 Use both hands to remove the FBG DCU module from the DCU chassis.

Removing the DCU Chassis Grounding

This procedure must be performed only after removing the FBG DCU module from the DCU chassis byperforming the steps listed in Removing the FBG DCU Module from the DCU Chassis, on page 12.

Note

Procedure

Step 1 Unscrew the lug screws from the grounding lug.Step 2 Disconnect the chassis ground strap from the FBG DCU chassis.Step 3 Disconnect the chassis ground strap from the office ground point or the rack ground point.

Removing the DCU Chassis from the Rack

Procedure

Step 1 Unscrew the rack mounting screws from the mounting brackets.Step 2 With both hands lift the DCU chassis out of the rack.Step 3 If required, unscrew the mounting brackets from the DCU chassis.

Cleaning and Maintaining Fiber-Optic ConnectorsConnector cleaning is required to maintain the performance of fiber-optic circuits. It is important that boththe LC/UPC connector at the end of the fiber-optic cable and the optical mating adapter on the front panel ofthe device are clean before the connection is made.

Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into beamsor view directly with optical instruments. Statement 1051

Warning

The following warning applies to disposal of chemicals and other materials used to clean connectors andadapters:

Installing the Cisco ONS 15216 FBG DCU 78-20751-01 13

Installing the Cisco ONS 15216 FBG DCURemoving the DCU Chassis Grounding

Page 14: Installing the Cisco ONS 15216 FBG DCU€¦ · Installing the FBG DCU Module in the DCU Chassis Procedure Step 1 AligntheFBGDCUmodulewiththeopeningonthefront-faceoftheDCUchassis.

Ultimate disposal of this product should be handled according to all national laws and regulations.Statement 1040

Warning

Before installing the fiber-optic cable, always perform the cleaning procedure for cable connectors describedin the following section. Whenever possible, inspect each connector before connecting it to the opticalmating adapter on the front panel.

Note

The LC optical mating adapter on the faceplate of the device is less likely to get dirty if it is capped whennot in use. On some devices, the optical mating adapter has a shutter. The shutter automatically closeswhen the LC/UPC connector is disconnected. This prevents entry of dirt.

The procedure for a thorough cleaning of these adapters is complicated. Use a commercially availablecleaning kit and closely follow the instructions included with the kit.

Note

Customer-supplied Cleaning MaterialsThe Type A fiber optic connector cleaners (for example, CLETOP reel) are recommended to clean the cableconnectors, but are not supplied with the device.

If properly maintained (only used with clean, defect-free fiber connectors and capped when not in use), themating adapter would not require cleaning. However, if you suspect the adapter is dirty, clean it by using theCLETOP stick swab.

For multifiber cable assemblies, use specific cleaning tools or materials designed for the assembly type.Note

Cleaning the Optical Mating Adapter

Procedure

Step 1 Read the cartridge cleaning instructions (provided by the manufacturer) to insert the cartridge cleaning tipinto the optical mating adapter.

Step 2 Slide the lever on the cartridge to swipe the mating surface.Always keep unused adapter ports and fiber connectors capped with a clean dust cap. The opticalmating adapters that have shutter need not be capped.

Note

Installing the Cisco ONS 15216 FBG DCU14 78-20751-01

Installing the Cisco ONS 15216 FBG DCUCustomer-supplied Cleaning Materials

Page 15: Installing the Cisco ONS 15216 FBG DCU€¦ · Installing the FBG DCU Module in the DCU Chassis Procedure Step 1 AligntheFBGDCUmodulewiththeopeningonthefront-faceoftheDCUchassis.

Cleaning Fiber-Optic Cable ConnectorsThe tools required to clean fiber connectors are:

• Inspection microscope

• Type A Fiber Optic Connector Cleaner (CLETOP reel)

• Optical swab

• Optical receiver cleaning stick

Procedure

Step 1 Using an inspection microscope, inspect each fiber connector for dirt, cracks, or scratches.Step 2 Replace any damaged fiber connectors.

Replace all dust caps whenever the equipment is unused for 30 minutes ormore.

Note

Do not reuse optical swabs. Keep unused swabs off of work surfaces.Caution

Step 3 Clean the fiber connectors with CLETOP reel:a) If present, remove the dust cap from the fiber connector.b) Press the lever down to open the shutter door. Each time you press the lever, you expose a clean wiping

surface.c) Insert the connector into the CLETOP cleaning cassette slot, rotate one-quarter turn, and gently swipe

downwards.d) Use an inspection microscope to inspect each fiber connector for dirt, cracks, or scratches. If the connector

is not clean, repeat the above sub-steps.e) Insert the fiber connector into the applicable adapter or attach a dust cap to the fiber connector.

Before replacing a dust cap on a connector, verify that the dust cap is clean. To clean the dust cap,wipe the outside of the cap using a dry, lint-free wipe and the inside of the dust cap using a CLETOPstick swab (14100400).

Note

FBG DCU Technical SpecificationsThese are the technical specifications for the Cisco ONS 15216 FBG DCU.

Optical SpecificationsThe Cisco ONS 15216 FBG DCU modules operate in the C-band within the wavelength range of 1528.77nm to 1566.31 nm at a 100 GHz grid spacing. Each module is designed to operate at a specific compensationlevel as listed in the following table.

Installing the Cisco ONS 15216 FBG DCU 78-20751-01 15

Installing the Cisco ONS 15216 FBG DCUCleaning Fiber-Optic Cable Connectors

Page 16: Installing the Cisco ONS 15216 FBG DCU€¦ · Installing the FBG DCU Module in the DCU Chassis Procedure Step 1 AligntheFBGDCUmodulewiththeopeningonthefront-faceoftheDCUchassis.

Table 1: Cisco ONS 15216 FBG DCU Optical Specifications

Compensation Level (nominal dispersion at 1545.31 nm)PIDModule

-165 ps/nm15216-FBGDCU-165=FBGDCU-165

-331 ps/nm15216-FBGDCU-331=FBGDCU-331

-496 ps/nm15216-FBGDCU-496=FBGDCU-496

-661 ps/nm15216-FBGDCU-661=FBGDCU-661

-826 ps/nm15216-FBGDCU-826=FBGDCU-826

-992 ps/nm15216-FBGDCU-992=FBGDCU-992

-1157 ps/nm15216-FBGDCU-1157=FBGDCU-1157

-1322 ps/nm15216-FBGDCU-1322=FBGDCU-1322

-1653 ps/nm15216-FBGDCU-1653=FBGDCU-1653

-1983 ps/nm15216-FBGDCU-1983=FBGDCU-1983

Connector SpecificationsThere are no optical connectors on the DCU chassis. The connectors are present only on the FBG DCUmodules as listed in the following table.

Table 2: Cisco ONS 15216 FBG DCU Optical Connector Specifications

Receptor TypeConnector TypeFunction

LC-UPC or LC-PC connectorLC-UPC connectorOptical-input

LC-UPC or LC-PC connectorLC-UPC connectorOptical-output

USBUSBInventory retrieval

Mechanical SpecificationsAll the individual Cisco ONS 15216 FBG DCU modules are of identical dimensions, which is listed in thefollowing table.

Table 3: Cisco ONS 15216 FBG DCU Mechanical Specifications

SpecificationParameter

41.1 mm x 208.2 mm x 204.9 mm

1.62 in. x8.20 in. x 8.07 in.

Dimensions (height x width x depth)

Installing the Cisco ONS 15216 FBG DCU16 78-20751-01

Installing the Cisco ONS 15216 FBG DCUConnector Specifications

Page 17: Installing the Cisco ONS 15216 FBG DCU€¦ · Installing the FBG DCU Module in the DCU Chassis Procedure Step 1 AligntheFBGDCUmodulewiththeopeningonthefront-faceoftheDCUchassis.

SpecificationParameter

Minimum: 0.5 kg (1.1 lb)

Maximum: 0.8 kg (1.8 lb)

Weight

Environmental SpecificationsOperate the Cisco ONS 15216 FBGDCUwithin the environmental specifications listed in the following table.

Table 4: Cisco ONS 15216 FBG DCU Environmental Specifications

SpecificationsParameter

MaximumMinimum

50° C-5° COperating temperature

122° F23° F

70° C-40° CStorage temperature

158° F-40° F

85%5%Relative humidity

Additional ReferencesUse this document in conjunction with the other release-specific documentation:

• Cisco ONS 15454 DWDM Configuration Guide

• Cisco ONS 15454 DWDM Troubleshooting Guide

• Cisco ONS Documentation Roadmap

Trademark NoticeCisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. andother countries. To view a list of Cisco trademarks, go to this URL: http://www.cisco.com/go/trademarks.Third-party trademarks mentioned are the property of their respective owners. The use of the word partnerdoes not imply a partnership relationship between Cisco and any other company. (1110R)

Installing the Cisco ONS 15216 FBG DCU 78-20751-01 17

Installing the Cisco ONS 15216 FBG DCUEnvironmental Specifications

Page 18: Installing the Cisco ONS 15216 FBG DCU€¦ · Installing the FBG DCU Module in the DCU Chassis Procedure Step 1 AligntheFBGDCUmodulewiththeopeningonthefront-faceoftheDCUchassis.

Obtaining Documentation and Submitting a Service RequestFor information on obtaining documentation, submitting a service request, and gathering additional information,see the monthlyWhat's New in Cisco Product Documentation, which also lists all new and revised Ciscotechnical documentation, at:

http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html

Subscribe to theWhat's New in Cisco Product Documentation as a Really Simple Syndication (RSS) feedand set content to be delivered directly to your desktop using a reader application. The RSS feeds are a freeservice and Cisco currently supports RSS version 2.0.

Installing the Cisco ONS 15216 FBG DCU18 78-20751-01

Installing the Cisco ONS 15216 FBG DCUObtaining Documentation and Submitting a Service Request