Page 1
Revision Record
Course Code ProductProduct
VersionCourse Version ISSUE
ONU101102 iManager U2000-
T
V100R001
V100R002
1.00
Developer/Modifier Time Approver New/Update
Don’t Print This Page
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page0
Developer/Modifier Time Approver New/Update
Wang Ruilin 2010-8 Zhou jinjun New development
Page 2
iManager U2000System Introduction
www.huawei.com
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved.
Page 3
Objectives
Upon completion of this course, you will be able to:
Describe the architecture and main features of U2000
Describe the directory structure of U2000
List the main functions of U2000 for transmission domain
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page2
Page 4
Contents
1. Architecture and Main Features of U2000
2. Directory Structure of U2000
3. Main Functions of U2000
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page3
Page 5
Contents
1. Architecture and Main Features of U2000
1.1 Telecommunications Management Network Concept
1.2 Network Management Layer of U2000
1.3 U2000 System Architecture
1.4 Interfaces of U2000
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page4
1.4 Interfaces of U2000
1.5 Managed Equipment of U2000
1.6 Hardware and Software Requirement
1.7 The User Interface of U2000
1.8 Processes of U2000
1.9 NMS Maintenance Suite: MSuite
1.10 License Introduction
Page 6
1.1 TMN Framework
OS
Tele
com
munic
atio
ns
Net
wo
rk
TMN
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page5
OS
OS
Data Communications Network
Tele
com
munic
atio
ns
Net
wo
rk
Page 7
Service Management Layer
Business Management Layer
SMS
NMS
BMS
Network Management Layer
1.1 Position of U2000 in TMN
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page6
Network Element Layer
Network Element Management Layer
NMS
EMS EMS EMS
Access
Transmission
Data
U2000 LCT
Network Management LayerHuawei
iManagerU2000
Page 8
1.2 Network Management Layer
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page7
Page 9
1.3 U2000 Server Architecture
Fullfillment
TDME2E
WDME2E
Assurance
Value-Added
FaultTest
Diagnosis
Unified NBI Framework
MTOSI CORBA SNMP …
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page8
U2000
Access Data
Transmission iMap Platform
Distributive NE Management Module
Transmission ……DataAccess
Packet E2E
E2E E2E
…
Added
Performance …
Page 10
1.3 Software Structure of U2000
U2000 server
XML/CORBA/SNMP/TL1/Text/…
XM
L
CO
RB
A
SNM
P
Text
NBI subsystem
Client Client Client … …
ClientOSS systemOSS system
Desktop server
... ...
Desktop server supports multiple instance
deploymentNE Explorer
supports multiple instance
V100R002
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page9
iMAP message bus (iMAP V3)
Alarm
To
po
log
y
Security
EAM
Common application (platform)
PT
N
MSAN
RouterTransport
Metro Ethernet
SNMP/TL1/MML/Qx/…Sw
itch
Ro
uter
Access
RT
N
SDH
OT
N
... ...NE Explorer
Inven
tory
DC
PM
S
IP C
om
mo
n
Common application (U2000)
SDH
E2E
WD
M E2
E
IP E2
E
... ...
E2E service management
PMS collector supports multiple
instance deployment
... ...
instance deployment
Page 11
MDP
Max. 100 Client OSS
1.3 Software Structure of U2000V100R001
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page10
IP
Max. 15k Physical NE, 22k equivalent NE
Access OTN
Database Server
E2ECommon
NBI
Physical Disk
PMsCollectors
PMCollectors
DC
Page 12
1.3 Software Structure of SingleServer
V100R001
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page11
Page 13
1.4 Interfaces of U2000
OSSOSSSyslog Server
Network SecurityAdministration
Syslog XML/CORBA/SNMP/ASCII
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page12
Access networkData network
AAA Server
Huawei iManagerU2000
Administration
Radius
Transmission network
CLI/SNMP/TL1
Qx/TL1
CLI/SNMP
Page 14
1.4 U2000 External InterfacesInventory Service
ProvisionPerformance
Syslog Server
CORBAXML/MTOSI
Alarm Server
NMS log
NMS alarm trap(SNMP)
Other
Text/TL1
Script
OSS
iManager T2100Transmission network
TransmissionOSS
Software
Network
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page13
BRAS
BRAS
EPE
NPE
VPLS/MPLS
NPE
MSE
MSE
EPE
EPE
IP/MPLS
VDSL2
IP MSAN
IPTV
IMS Core
Internet/SP
Business
ONT
OLT
UPE
EPE
AG
VC12/VC4 WDM
WDM
MSTP
MSTP
MSTP
MSTP MSTP
Radius server
AAA Server
Huawei iManagerU2000
NE alarm trap(SNMP)
NE log(Syslog)
NE configuration(CLI/TL1/Qx)
NE performance(FTP)
Radius
NMS log(Syslog)
CEAS
iManager T2100
Device Information(Script/XML)
Transmission network(MML)
Network Security
Administration
Page 15
1.5 Managed Equipment of U2000
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page14
Datacom Transmission Access
ME, Router, Switch,
Securtiy, PTN, CX, SIG
SDH, WDM, RTN, MSTP+,
Submarine
BSL
MA
Page 16
1.6 Typical Hardware RequirementNetwork Scale
PC Server (Single-Server System)
Sun ServerBlade Machine
(Distributed Mode)
Small scale (less than
2,000 equivalent NE)
HP DL380G6 (CPU: 2 x Xeon quatri-core 2.0 GHz or later; memory: 8 GB; hard disk: 5 x 146 GB)
Sun T5220 (CPU: 4C x 1.2 GHz; memory: 16 GB; hard disk: 6 x 146 GB)
Blade server: 1 x blade
Medium scale (less than
6,000
HP DL580G5 (CPU: 4 x Xeon quatri-core 2.13 GHz or later; memory:
Sun T5220 (CPU: 8C x 1.4 GHz; memory: 32 GB; hard
Blade server: 3 x blade
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page15
6,000 equivalent NE)
GHz or later; memory: 16 GB; hard disk: 4 x
146 GB)
GHz; memory: 32 GB; hard disk: 6 x 146 GB) Disk array: 6 x 300 GB
Large scale (less than 15,000
equivalent NE)
-
Sun M4000 (CPU: 4CPU x
2.53GHz (quatri-core);
memory: 32 GB; hard disk:
2 x 146 GB) + disk array
Blade server: 5 x blade
Disk array: 6 x 300 GB
Super Large scale (less
than 20,000 equivalent NE)
-
Sun M5000 (CPU: 8CPU x
2.53GHz (quatri-core);
memory: 64 GB; hard disk:
2 x 146 GB) + disk array
Blade server: 6 x blade
Disk array: 6 x 300 GB
Page 17
1.6 Typical Software Requirement
OS& DB U2000 V1R1 U2000 V1R2 U2000 V1R3
Window
s
(32bit)
OS Windows Server 2003R2 + SP2Windows Server 2008R2 Enterprise
Windows 7
DB SQLServer 2000 Standard +SP4SQL Server2008 Standard
SQL Server 2008 Express
UNIX OS Solaris 10 (10/08)
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page16
ServerUNIX
(64bit)
OS Solaris 10 (10/08)
DB SYBASE 15.0.3 + EBF16476 + EBF 16548
Linux
(64bit)
OS SUSE Linux 10 SP2
DB
SYBASE 12.5.4
+ EBF 15447 +
EBF 16000
Oracle 11g Enterprise Edition Release 11.1.0.6.0
Client Window
s
(32bit)
OS Windows Vista Business + SP1 + JDK 1.6
LCT OS+DB Windows Vista Business + SP1 + MSSQL Server 2008 Express
Page 18
1.7 User Interface of U2000
Main Topology View
3 in 1 View Filter
ShortcutsFunction Menus Alarm Indicators
Abnormal Event Indicator
NM Tasks Management Progress Networkwide Maintenance Status
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page17
Topology Objects
Page 19
1.7 User Interface of U2000
Main Topology View
3 in 1 View FilterTopology Objects
ShortcutsFunction Menus Alarm Indicators
Abnormal Event Indicator
NM Tasks Management Progress
Networkwide Maintenance Status
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page18
Page 20
1.8 Processes of U2000
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page19
Page 21
1.8 Processes of U2000
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page20
Page 22
1.9 NMS Maintenance Suite: MSuiteV100R002
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page21
Page 23
1.9 NMS Maintenance Suite: MSuiteV100R001
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page22
Page 24
1.10 License IntroductionResource
Management scale
Number of manageable device
Number of collector
Number of PMS task
Number of client
……
Others
Customized interface
Customized reporter
License expiration control
Dynamical license load
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page23
……
Fundamental packets
Unified management engine
NE management software
Value-added function
Interface software
Software/Function
Page 25
Contents
1. Architecture and Main Features of U2000
2. Directory Structure of U2000
3. Main Functions of U2000
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page24
Page 26
2.1 Main Directory Structure of U2000V100R002
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page25
Page 27
2.1 Main Directory Structure of U2000V100R001
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page26
Page 28
2.2 U2000 Server Directory StructureV100R002
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page27
Page 29
2.2 U2000 Server Directory StructureV100R001
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page28
Page 30
Contents
1. Architecture and Main Features of U2000
2. Directory Structure of U2000
3. Main Functions of U2000
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page29
Page 31
U2000 Main Management FunctionsFunction Description
Topology Management
Unified topology object managementUnified topology operation
Network Management
Protection subnet managementClock network managementDCN management
E2E Management
E2E service deployment
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page30
Management
Fault Management
Unified fault managementUnified management of fault location, service alarm and fault experience
Performance Management
Unified historical and real-time performance monitoring Unified performance operation
Inventory Management
Unified physical inventory managementUnified fiber management
Security and data Management
Unified NMS, NE and user security managementUnified data backup and restoring
NBI Unified CORBA, SNMP, XML, TXT interface
Page 32
3.1 Topology Management
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page31
Page 33
3.1 Topology Management
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page32
Page 34
3.1 NE PanelNE Status Tool Bar Alarm Indicator
Slots
Slots Layout
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page33
Board Port Alarm Indicator
Board Description
Page 35
3.1 NE ExplorerNE Name
Board
Function Tree
NE PanelSwitch NE Backup NE Database to SCC
Help
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page34
Function Tree Control Keys
Function Title
Page 36
3.1 NE Explorer: Service Conf.
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page35
Page 37
3.1 NE Explorer: Overhead Conf.
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page36
Page 38
3.1 NE Explorer: Parameter Conf.
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page37
Page 39
3.1 NE Explorer: Communication
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page38
Page 40
3.2 SDH Networking Protection
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page39
Page 41
3.2 SDH Network Protection Maintenance
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page40
Page 42
3.2 Clock Management
Clock Source Type
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page41
Page 43
3.2 Clock Management
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page42
Clock Source Priority
Page 44
3.2 DCN Management
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page43
Page 45
3.3 U2000 Service Management
Transmission E2E
PTN Tunnel Management
PWE3 Management
E-Line/E-Agg Management
PTN E2E
SDH/WDM Dual-plane
RTN, SDH Composite
Networking
RTNE2E
SDHE2E
ASON
WDME2E
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page44
IP E2E Management
Service Alarm
Service Management
L3VPN Management Intelligent Networking
MSTP+
Tunnel Management
PWE3 Management
VPLS Management
L3VPN Management
Composite Service
Management
SDH/WDM service
connectivity
Fault locating
LSP
Page 46
3.3 SDH Trail Configuration
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page45
Page 47
3.3 SDH Trail Management
Part A
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page46
Part B
Part C
Part D
Page 48
3.3 MSTP+ Tunnel E2EConfiguration
V100R002
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page47
Page 49
3.3 MSTP+ Tunnel E2EManagement
V100R002
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page48
Page 50
3.3 MSTP+ PWE3 E2EConfiguration
V100R002
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page49
Page 51
3.3 MSTP+ PWE3 E2EManagement
V100R002
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page50
Page 52
3.4 Fault Management
Alarm color
Alarm browsing Alarm sort Dynamic alarm board
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page51
Alarm filerAlarm details Alarm reason and advice
Alarm colorindication Alarm deal
with methods
Page 53
3.4 Alarm Attribute Template
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page52
Page 54
3.4 Alarm Attribute Template
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page53
Page 55
1. Alarm indicator is Blinking, new generated alarm
2. Click the alarm indicator
3.4 Alarm Allocation
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page54
3. Open NE Panel4.The failure board or port
Page 56
3.5 Performance Management
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page55
Page 57
3.5 Performance Management
Abundant service quality indicator
High efficiency management
In time problem Detection
Quick problem location
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page56
Stably Running Network
Page 58
3.6 Inventory Management
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page57
Page 59
3.6 Uniform Fiber/Cable Management
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page58
Page 60
3.6 Drawings and Reports
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page59
Page 61
3.7 Security Management
U2000 ClientU2000 Server
DCN
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page60
U2000 Client
U2000 Client
OSS
NetworkNetwork
DCN
Page 62
3.7 Security Management
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page61
Page 63
①Scheduled Backup
Backup
3.7 Database Backup & Restore
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page62
U2000
External Storage
②Manual Backup Restore...
Page 64
3.8 NBI Interface
OSS(Access)
OSS(Data)
OSS(Transmit)
OSS(Transmit)
OSS(Access)
OSS(Data)
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page63
SNMP CORBA XML TXT
iManager DMS Server
iManager BMS Server
iManager T2000 Server
iManager U2000 Server
Page 65
3.8 Northbound Interface
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page64
Page 66
Questions
Which layers are there in the TMN architecture by ITU_T?
How many types of interface are there for U2000? What are
they?
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page65
Where are the files of U2000 server, client, sysmonitor, MSuite
server and client?
Page 67
Summary
List Content Main Realization Means
1 Topology Management Main topology view/NE panel/NE Explorer
2 Network ManagementProtection Subnet/Clock View/DCN
Management
3 E2E Management Service Trail menu
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page66
3 E2E Management Service Trail menu
4 Fault Management Fault menu
5 Performance Management Performance menu
6 Inventory Management Inventory menu
7Security and data Management
Administration menu, NMS MSuite tool
8 NBI NMS MSuite tool
Page 68
Thank youwww.huawei.comwww.huawei.com