Click here to load reader
Sep 13, 2018
hidglobal.com
PLT-03331, Rev. A.2
INSTALLATION GUIDE
SpecificationsRKL40 RPKL40 RKLB40
BASE PART NUMBER 929N 929P 928N
INPUT VOLTAGE (VDC) 12VDC 12VDC 12VDC
CURRENT
STANDBY AVG1 170mA 170mA 195mA
MAX AVG2 185mA 185mA 255mA
PEAK3 250mA 250mA 320mA
OPERATING TEMPERATURE
-4F to 149F(-20C to 65C)
-4F to 149F(-20C to 65C)
14F to 122F(-10C to 50C)
CABLE LENGTH Communication LinesWiegand
500ft - 22 AWG (152m)300ft - 24 AWG (91m)
RS-485Max Bus Length: 4000ft (1,219m) - 24 AWG
Max Lenth Between Nodes: 1640ft (500m) - 24 AWG
UL REF NUMBER4 RKL40Ex1x2x3 RPKL40Ex1x2x3 RKLB40Ex1x2x3SRD MODEL RKCL40E RPKCL40E RKCLB40E
1Standby AVG - RMS current draw without a card in the RF field.Maximum AVG - RMS current draw during continuous card reads. Not evaluated by UL.3Peak - highest instantaneous current draw during RF communication.4UL Reference Number Deciphering
x1 Reader Colors K = Black, G = Gray
x2 Wiring N = Pigtail, T = Terminal
x3 Communications N = No Module, R = RS-485
Parts Reader and base plate assembly (1) Installation Guide (1) iCLASS SE Biometric Reader User Guide (RKCLB40 only) (1) Terminal connector (2) M3.5 mm x 12 mm Phillips machine screw (4) #6-32 x .375" Phillips self-tapping machine screw (4) #6 x 1.5" Phillips sheet metal screw (4) #6-32 x .4375" Spanner security screw, anti-tamper (black) (3) #6-32 x .4375" Phillips security screw (black) (3) Mounting Gasket (1) SE BIO Initial Setup Reset Card 1 (RKLB40 only) SE BIO Initial Setup Reset Card 2 (RKLB40 only)
Recommended Cable, 4 conductor, 22 or 24 AWG (65 mm or 51 mm) twisted pair, over-all shield and UL approved (Belden 3107A, or equivalent) - RS485 + power Cable, 6 to 9 conductor, 22 or 24 AWG (65 mm or 51 mm) over-all shield, (Alpha 1296C or equivalent) - Wiegand + power DC power supply Metal or plastic double-gang junction box Reader spacer when mounting on or near metal or metal junction boxes - see How to Order Guide Security tool (for spanner security screw, anti-tamper) HID 04-0001-03
iCLASS SE Biometric/iCLASS SE Display ReaderRKL40, RPKL40, RKLB40SRD MODEL: RKCL40E, RPKCL40E, RKCLB40E
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output are fictitious. Specifications are subject to change without notice.
2017 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID Brick Logo, the Chain Design, and iCLASS SE are trademarks or registered trademarks of HID Global in the U.S. and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.
RKL40, RPKL40, RKLB40SRD MODEL: RKCL40E, RPKCL40E, RKCLB40E
iCLASS SE Biometric/iCLASS SE Display Reader PLT-03331, Rev. A.2
2
PIGTAIL TERMINAL DESCRIPTIONYellow P1-1 Beeper Input
Orange P1-2 LED Input (GRN)
Black P1-3 Ground (RTN)
Red P1-4 +VDC
Drain P1-5 Unused
Brown P1-6 LED Input (RED)
Blue P1-7 Hold Input
Red/Green P2-7 GPIO1/OSDP (RS485-FDX/HDX-A)
Tan P2-6 GPIO2/OSDP (RS485-FDX/HDX-B)
Violet P2-5 *Open Collector Output / Tamper
White P2-4 **Wiegand Data 1 / Clock
Green P2-3 **Wiegand Data 0 / Data
Pink P2-2 GPIO3 (RS485-FDX-Z)
Gray P2-1 GPIO4 (RS485-FDX-Y)
Wall backplate
Install gasket
Junction box not included
ATTENTIONObserve precautions for handling ELECTROSTATIC SENSITIVE DEVICES
P1
P2
BeeperGRN LED
GND+VDC
DRAINRED
HOLD
GPIO1GP102OC/TMPRDATA1/CLKDATA2/DATAGPIO3GPIO4
BeeperGRN LED
GND+VDC
DRAINRED
HOLD
GPIO1GP102OC/TMPRDATA1/CLKDATA2/DATAGPIO3GPIO4
1 Mounting
2 Wiring
Mounting holes for US double-gang electrical boxes.
Terminal Reader(Terminal block and
module position varies)
Notes Previous iCLASS readers had reversed RS-485 wiring (P2-7 & P2-6 - A & B). When upgrading to an iCLASS SE reader, ensure proper connections as defined below. It is possible to reuse existing Wiegand wiring for OSDP, however, using simple stranded cable typical of Wiegand access control readers is usually not meeting the RS485 twisted pair recommendations. For OSDP cable lengths greater than 200ft. (61M) or EMF interference, install 120 +/- 2 resistor across RS-485 termination ends. Wiring the reader incorrectly may permanently damage the reader.
Reverse ConfigurationRotating the backplate 180 allows for placing the LCD display on left and the reader on right.See PLT-02969 - Alternate Reader Assembly for instructions, before proceeding to Step 2: Wiring.Scan the QR Code or visit www.hidglobal.com/PLT-02969
RKL40, RPKL40, RKLB40SRD MODEL: RKCL40E, RPKCL40E, RKCLB40E
iCLASS SE Biometric/iCLASS SE Display Reader PLT-03331, Rev. A.2
3
3 Attach to Backplate
Mount the Reader Assembly (Reader, LCD Assembly, and reader backplate)
to the wall backplate.
Standard Configuration: Slide Reader Assembly towards the right to lock.
Alternate Configuration: Slide Reader Assembly to the left to lock.
Install Security screws.
4 Power and Testing
Notes With a keypad reader, operating as 26 bit emulation; upon power up you have five seconds to enter the Facility Code followed by #. If unsuccessful, the reader LED displays solid Red. Power-cycle the reader and retry entering the Facility Code. The Facility Code needs to be manually entered as three digits (i.e. a Facility Code of 10 is entered as 0-1-0-#). SE readers only use Facility Codes between 1-255, and there is no default Facility Code. Once the Facility Code has been entered, the LED will display Violet and then to Red. Power-cycle the reader to complete the Facility Code configuration. When using a keypad, if two short beeps are heard after entering your PIN, the reader does not have a Facility Code configured yet. In this event, an Admin will need to power-cycle the reader and enter the Facility Code before the reader will accept a PIN.
hidglobal.com
PLT-03331, Rev. A.2
GUIDE D'INSTALLATION
CaractristiquesRKL40 RPKL40 RKLB40
RFRENCE DE BASE 929N 929P 928N
TENSION D'ENTRE (Vcc) 12Vcc 12Vcc 12Vcc
COURANT
MOY VEILLE1 170mA 170mA 195mA
MOY MAX.2 185mA 185mA 255mA
CRTE3 250mA 250mA 320mA
TEMPRATURE DE FONCTIONNEMENT
-4F 149F(-20C 65C)
-4F 149F(-20C 65C)
14F 122F(-10C 50C)
LONGUEUR DE CBLE Lignes de communicationWiegand
500' - 22 AWG (152m)300' - 24 AWG (91m)
RS-485Long. max du bus : 4000' (1219m) - 24 AWG
Distance max. entre nuds : 1640' (500m) - 24 AWG
NUMRO DE RF. UL4 RKL40Ex1x2x3 RPKL40Ex1x2x3 RKLB40Ex1x2x3MODLE SRD RKCL40E RPKCL40E RKCLB40E
1 MOY veille: courant efficace sans carte dans le champ RF.MOY max.: courant efficace durant les lectures de carte continues. Non valu UL.3 Crte: courant instantan le plus lev durant une communication RF.4 Dcryptage du numro de rfrence UL
x1 Couleurs du lecteur:
K = Noir, G = Gris
x2 Cblage N = Pigtail, T = Borne
x3 Communications N = aucun module, R = RS-485
Pices Ensemble lecteur et socle (1) Guide d'installation (1) Guide de l'utilisateur du lecteur biomtrique iCLASS SE (RKCLB40 uniquement) (1) Connecteur de borne (2) Vis mtaux Phillips M3,5mm x 12mm (4) Vis autotaraudeuse Phillips n6-32 x 0,375 (4) Vis tle Phillips n6 x 1,5 (4) Vis de fixation entretoise n6-32 x 0,4375, inviolable (noire) (3) Vis de fixation Phillips n6-32 x 0,4375 (noire) (3) Support d'assemblage (1) Carte de rinitialisation 1 pour la configuration initiale du SE BIO (RKLB40 uniquement) Carte de rinitialisation 2 pour la configuration initiale du SE BIO (RKLB40 uniquement)
Pices recommandes Cble 4conducteurs 22 ou 24AWG [65mm ou 51mm] paires torsades, entirement blind et homologu UL (Belden 3107A ou quivalent) - RS-485 + alimentation Cble 6 9conducteurs 22 ou 24AWG [65mm ou 51mm] entirement blind (Alpha 1296C ou quivalent) - Wiegand + alimentation Alimentation cc Botier de raccordement double commande en mtal ou plastique Pice d'espacement pour le montage sur ou proximit de mtal ou de botiers de raccordement en mtal - voir le Guide des commandes Outil de scurit (pour vis de fixation entretoise inviolable) HID 04-0001-03
Lecteur biomtrique iCLASS SE/Lecteur iCLASS SERKL40, RPKL40, RKLB40MODLE SRD : RKCL40E, RPKCL40E, RKCLB40E
RKL40, RPKL40, RKLB40SRD MODEL: RKCL40E, RPKCL40E, RKCLB40E
iCLASS SE Biometric/iCLASS SE Display Reader PLT-03331, Rev. A.2
5
PIGTAIL BORNE DESCRIPTIONJaune P1-1 Entre bip
Orange P1-2 Entre LED (VERT)
Noir P1-3 Masse (RTN)
Rouge P1-4 +V cc
Drain P1-5 Non utilis
Marron P1-6 Entre LED (ROUGE)
Bleu P1-7 Entre Hold
Rouge/Vert P2-7 GPIO1/OSDP (RS485-FDX/HDX-A)
Brun P2-6 GPIO2/OSDP (RS485-FDX/HDX-B)
Violet P2-5 *Sortie collecteur ouvert/Scurit
Blanc P2-4 **Donnes Wiegand 1 / Clock
Vert P2-3 **Donnes Wiegand 0 / Data
Rose P2-2 GPIO3 (RS485-FDX-Z)
Gris P2-1 GPIO4 (RS485-FDX-Y)
Plaque murale
Installer le support
Botier de raccordement non inclus
ATTENTIONLes manipulations des APPAREILS SENSIBLES AUX DCHARGES LECTROSTATIQUES doivent tre effectues avec prcaution.
P1
P2
BeeperGRN LED
GND+VDC
DRAINRED
HOLD
GPIO1GP102OC/TMPRDATA1/CLKDATA2/DATAGPIO3GPIO4
BeeperGRN LED
GND+VDC
DRAINRED
HOLD
GPIO1GP102OC/TMPRDATA1/CLKDATA2/DATAGPIO3GPIO4
1 Montage
2 Cblage
Trous de fixation pour les coffrets lectriques double commande amricains.
Lecteur d