Replacing Plug-in Units and Other Hardware Units DN70216177 Issue 1-0 en # Nokia Siemens Networks 1 (179) 3GNDOCU3CNEDAC.20 Nokia Multimedia Gateway, Rel. U3C, Product Documentation
Replacing Plug-in Units and OtherHardware Units
DN70216177Issue 1-0 en
# Nokia Siemens Networks 1 (179)
3GNDOCU3CNEDAC.20Nokia Multimedia Gateway, Rel. U3C, ProductDocumentation
The information in this document is subject to change without notice and describes only theproduct defined in the introduction of this documentation. This documentation is intended for theuse of Nokia Siemens Networks customers only for the purposes of the agreement under whichthe document is submitted, and no part of it may be used, reproduced, modified or transmitted inany form or means without the prior written permission of Nokia Siemens Networks. Thedocumentation has been prepared to be used by professional and properly trained personnel,and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomescustomer comments as part of the process of continuous development and improvement of thedocumentation.
The information or statements given in this documentation concerning the suitability, capacity, orperformance of the mentioned hardware or software products are given “as is” and all liabilityarising in connection with such hardware or software products shall be defined conclusively andfinally in a separate agreement between Nokia Siemens Networks and the customer. However,Nokia Siemens Networks has made all reasonable efforts to ensure that the instructionscontained in the document are adequate and free of material errors and omissions. NokiaSiemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues whichmay not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NOEVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THISDOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL,DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUTNOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESSOPPORTUNITY OR DATA, THAT MAYARISE FROM THE USE OF THIS DOCUMENT OR THEINFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights andother intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark ofNokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective owners,and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2007. All rights reserved.
2 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Contents
Contents 3
1 Plug-in unit is faulty 5
2 Taking unit out of use 9
3 Replacing plug-in unit with the same variant 15
4 Replacing plug-in unit with newer variant 23
5 Replacing CCPC2–A plug-in unit with CCP10 (OMU) 31
6 Replacing ESA12 plug-in unit with ESA24 41
7 Replacing MCPC2 plug-in unit with MCP18(-B) 49
8 Replacing MCPC2-A plug-in unit with MCP18(-B) 57
9 Replacing interface units 63
10 MCPC2(-A) plug-in unit is faulty 71
11 MCP18(-B) plug-in unit is faulty 75
12 PD20 plug-in unit is faulty 79
13 Fuse in PD20 plug-in unit is faulty 85
14 PD30 plug-in unit is faulty 87
15 Fuse in PD30 plug-in unit is faulty 93
16 ESA12 plug-in unit is faulty 95
17 ESA24 plug-in unit is faulty 103
18 BIE1C/T back interface unit is faulty 109
19 Fan tray is faulty 115
20 Fan tray (FTRA-B) is faulty 127
21 Hard disk is faulty 135
22 NEMU hard disk fails 141
23 MCPC2(-A), Primary operating system disk has failed, disk 0 143
DN70216177Issue 1-0 en
# Nokia Siemens Networks 3 (179)
Contents
24 MCPC2(-A), Secondary operating system disk has failed, disk 1 147
25 MCP18(-B), Primary operating system disk has failed, disk 0 151
26 MCP18(-B), Secondary operating system disk has failed, disk 1 155
27 Hard disk (HDS-B) is faulty 159
Related Topics 175
4 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
1 Plug-in unit is faultyDescription
When a plug-in unit is faulty, you must replace it with a plug-in unit of thesame or newer variant.
For more information on plug-in units, see either Nokia WCDMA RadioNetwork Controller Plug-in Unit Descriptions or Nokia Multimedia GatewayPlug-in Unit Descriptions in PDF format in NOLS.
Symptoms
A plug-in unit is faulty and needs to be replaced.
Recoveryprocedures
Replacing plug-in unit with the same variant
If you are replacing a plug-in unit with the same variant, follow theinstructions in Replacing plug-in unit with the same variant.
Some plug-in units cannot be replaced by using those instructions. TableInstructions for replacing plug-in units with the same variant gives a list ofthe plug-in units that must be replaced according to instructions specifiedin the latter column.
Table 1. Instructions for replacing plug-in units with the same variant
Plug-in unit See instructions in
MCP18 or MCP18-B (NEMU) MCP18(-B) plug-in unit is faulty
MCPC2 or MCPC2-A (NEMU) MCPC2(-A) plug-in unit is faulty
PD20 (subrack power supply) PD20 plug-in unit is faulty
PD30 (subrack power supply) PD30 plug-in unit is faulty
DN70216177Issue 1-0 en
# Nokia Siemens Networks 5 (179)
Plug-in unit is faulty
Table 1. Instructions for replacing plug-in units with the same variant (cont.)
Plug-in unit See instructions in
ESA12 (Ethernet switch) ESA12 plug-in unit is faulty
ESA24 (Ethernet switch) ESA24 plug-in unit is faulty
Replacing plug-in unit with a newer variant
If you are replacing a plug-in unit with a newer variant, follow theinstructions in Replacing plug-in unit with newer variant.
Some plug-in units cannot be replaced by using those instructions. TableReplacing plug-in units with newer variants gives a list of the plug-in unitsthat must be replaced according to instructions specified in the lattercolumn.
Table 2. Replacing plug-in units with newer variants
Old plug-in unit New plug-in unit See instructions in
CCPC2-A (OMU) CCP10 (OMU) Replacing CCPC2–A plug-in unit withCCP10 (OMU)
ESA12 ESA24 Replacing ESA12 plug-in unit withESA24
MCPC2 (NEMU) MCP18 or MCP18-B (NEMU) Replacing MCPC2 plug-in unit withMCP18(-B) plug-in unit
MCPC2-A (NEMU) MCP18 or MCP18-B (NEMU) Replacing MCPC2-A plug-in unit withMCP18(-B)
Replacing other hardware equipment
If you are replacing other hardware equipment, see Table Instructions forreplacing other hardware equipment for which instructions to follow.
Table 3. Instructions for replacing other hardware equipment
Hardware equipment See instructions in
BIE1C or BIE1T back interface unit BIE1C/T back interface unit is faulty
Fan tray Fan tray is faulty
Fan tray (FTRA-B) Fan tray (FTRA-B) is faulty
6 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Table 3. Instructions for replacing other hardware equipment (cont.)
Hardware equipment See instructions in
Fuse in PD20 plug-in unit Fuse in PD20 plug-in unit is faulty
Fuse in PD30 plug-in unit Fuse in PD30 plug-in unit is faulty
OMU hard disk (HDS9/HDS-A) Hard disk is faulty
NEMU hard disk (HDS9/HDS-A) NEMU hard disk fails
HDS-B NEMU and OMU hard disks HDS-B is faulty
MCPC2 or MCPC2-A (NEMU) primary operatingsystem disk
MCPC2(-A), Primary operating system disk has failed,disk 0
MCPC2 or MCPC2-A (NEMU) secondaryoperating system disk
MCPC2(-A), Secondary operating system disk has failed,disk 1
MCP18 or MCP18-B (NEMU) primary operatingsystem disk
MCP18(-B), Primary operating system disk has failed,disk 0
MCP18 or MCP18-B (NEMU) secondaryoperating system disk
MCP18(-B), Secondary operating system disk has failed,disk 1
DN70216177Issue 1-0 en
# Nokia Siemens Networks 7 (179)
Plug-in unit is faulty
8 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
2 Taking unit out of usePurpose
Note
Note that the equipment database does not recognise MCPC2,MCPC2-A, MCP18 or MCP18-B plug-in units, and they do not haveworking states.
If you want to diagnose a unit, for example, first change the unit workingstate to TE-EX, then diagnose it and after the diagnosis take the unit backinto use.
If you need to take a unit out of use, the unit working state has to bechanged from WO to TE or SP and then to SE.
If the unit has ongoing tasks (for example, it is currently loading someinformation to disk) which cannot be interrupted in a controlled way, onlyuse the FCD parameter if you have to. It is recommended to wait a whileand try taking the unit out of use again later.
Table 4. The plug-in unit's LED display with different working states
Working state LED display
WO-EX Green
WO-RE Green blink
BL-EX Green
BL-ID Green
BL-RE Green blink
SP-EX Orange
SP-UP Green blink
DN70216177Issue 1-0 en
# Nokia Siemens Networks 9 (179)
Taking unit out of use
Table 4. The plug-in unit's LED display with different working states (cont.)
Working state LED display
SP-RE Green blink
TE-EX Red blink
TE-RE Red blink
SE-OU Red
SE-NH None
TR-OU Undefined
Before you start
If you want to remove a plug-in unit, change the state of the unit to SE-NHby following the procedure below.
The following figures describe working state transitions from normalworking state, WO-EX or SP-EX, to SE-NH.
If the unit whose working state you are changing is not redundant or isredundant by the load-sharing principle, change the state of the unitdirectly to TE, or first to BL state and then to TE state.
Figure 1. Taking an SN+ or non-redundant unit out of use using the BLworking state
WO-EX
SE-NH
BL-EX
SE-OU
BL-ID
TE-EX
(by user
(by user
(by system
(by user
(by user
) )
)
))
10 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Figure 2. Taking an SN+ or non-redundant unit out of use, when the unit doesnot have a BL working state
If the unit whose working state you are changing is a 2N or N+1 replacableredundant unit, change the state of the unit first to SP and then to TE.
Figure 3. Taking an active 2N or N+1 redundant unit out of use
Steps
1. Check the unit working state (USI)
ZUSI:<unit type>;
When replacing a plug-in unit, the functional units of the plug-in unitmust be in SE-NH state.
Expected outcome
When the working state of a plug-in unit's functional unit is SE-NH,the LED display is off. In this working state you can continuereplacing the plug-in unit if needed.
Unexpected outcome
If the working state of a plug-in unit's functional unit is other than SE-NH, go to step 2 or 3.
WO-EX(by user
TE-EX(by user
SE-OU(by user
SE-NH) ) )
WO-EX SP-EX
SE-NH
TE-EX
SE-OU
(by user (by user
(by user
(by user
) )
)
)
DN70216177Issue 1-0 en
# Nokia Siemens Networks 11 (179)
Taking unit out of use
2. If the working state of the unit you are taking out of use is WO-EX
Then
Change the state of the unit to SP or BL-EX (USC)
ZUSC:<unit type>,<unit index>:SP;
or
ZUSC:<unit type>,<unit index>:BL;
Note
Not all units have BL state.
If the unit has a long-running resource, it will stay in the BL-EX state.In that case, follow the instructions in Working state change fails.
Else
If the unit working state is other than WO-EX, go to the next step
3. Change the unit working state to TE (USC)
ZUSC:<unit type>,<unit index>:TE;
4. Change the unit working state to SE-OU (USC)
ZUSC:<unit type>,<unit index>:SE;
5. Change the unit working state to SE-NH (USC)
Note
A plug-in unit can only be removed when its functional units are in theSE-NH state. Also, a functional unit can only be removed from thesystem after it has been set to the SE-NH state (separated, nohardware) using the USC command.
ZUSC:<unit type>,<unit index>:SE;
Example Changing the state of the unit directly to TE
12 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Change the state of A2SU directly from WO to TE, using the FCDparameter.
ZUSC:A2SU,0:TE::FCD;
When you change the state of the unit, the following prompt appearsasking you to confirm the command execution:
FORCED STATE TRANSITION REQUESTED
WO-EX -> TE
CONFIRM COMMAND EXECUTION: Y/N? Y
STATE OF SOME CHILD UNITS MAY ALSO BE CHANGED
CONFIRM COMMAND EXECUTION: Y/N? Y
Example Changing the state of the unit first to BL, then TE and SE
1. Change the working state of the DMCU unit from working state WOto BL-EX.
ZUSC:DMCU,<index>:BL;
When the unit is in working state BL-EX, the system changes it toBL-ID. When the working state is BL-ID, you can proceed andchange it to TE.
2. Change the working state from BL to TE.
ZUSC:DMCU,<index>:TE::;
3. Change the working state from TE to SE-OU.
ZUSC:DMCU,<index>:SE::;
4. Change the working state from SE-OU to SE-NH.
ZUSC:DMCU,<index>:SE::;
Example Changing the state of A2SU unit first to BL, then TE and SE
Change the state of A2SU fromWO to BL, then to TE and SE. Note that forA2SU units you always need to perform a forced state transition usingparameter state transition control.
1. Change the working state of the A2SU unit from WO-EX to BL-ID.
Use the value FCD for the state transition control parameter toset the A2SU from WO-EX to BL-ID.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 13 (179)
Taking unit out of use
Note
This command causes disturbances in network traffic.
ZUSC:A2SU,<index>:BL::FCD:;
2. Change the working state from BL-ID to TE-EX.
ZUSC:A2SU,<index>:TE::;
3. Change the working state from TE-EX to SE-OU.
ZUSC:A2SU,<index>:SE::;
4. Change the working state from SE-OU to SE-NH.
ZUSC:A2SU,<index>:SE::;
Example Changing the state of the unit first to SP and then to TE
Change the working state of OMU-1 from WO-EX to TE. Both OMUs are innormal working state
This command activates OMU's switchover. The working state of OMU-1changes to SP-EX and the working state of OMU-0 changes to WO-EX.
ZUSC:OMU,1:SP;
ZUSC:OMU,1:TE;
Example Changing the state of the unit from TE to SE-OU and then toSE-NH
Change the working state of OMU-1 from TE-EX to SE-NH
1. First, change the working state from TE-EX to SE-OU.
ZUSC:OMU,1:SE;
2. Then, change the working state from SE-OU to SE-NH.
ZUSC:OMU,1:SE;
14 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
3 Replacing plug-in unit with the samevariant
Purpose
This procedure describes how to replace a plug-in unit with the samevariant. A plug-in unit needs to be replaced if it is faulty or sometimes whenthe network element configuration is changed.
Some plug-in units or hardware equipment cannot be replaced by usingthese instructions. Table Instructions for replacing plug-in units andhardware equipment gives a list of the plug-in units and hardwareequipment that must be replaced according to instructions specified in thelatter column.
Note
When replacing the ESA12 and ESA24 plug-ins with the same variant,first take a backup of the configuration file of the old switch beforeinstalling the new switch.
Table 5. Instructions for replacing plug-in units and hardware equipment
Plug-in unit or hardware equipment See instructions in
MCP18 or MCP18-B (NEMU) MCP18(-B) plug-in unit is faulty
MCPC2 or MCPC2-A (NEMU) MCPC2(-A) plug-in unit is faulty
PD20 (subrack power supply) PD20 plug-in unit is faulty
ESA12 (Ethernet switch) ESA12 plug-in unit is faulty
ESA24 (Ethernet switch) ESA24 plug-in unit is faulty
BIE1C or BIE1T back interface unit BIE1C/T back interface unit is faulty
Fuse in PD20 plug-in unit Fuse in PD20 plug-in unit is faulty
DN70216177Issue 1-0 en
# Nokia Siemens Networks 15 (179)
Replacing plug-in unit with the same variant
Table 5. Instructions for replacing plug-in units and hardware equipment(cont.)
Plug-in unit or hardware equipment See instructions in
Fan tray Fan tray is faulty
OMU hard disk Hard disk is faulty
NEMU hard disk NEMU hard disk fails
MCPC2 or MCPC2-A (NEMU) primary operatingsystem disk
MCPC2(-A), Primary operating system disk has failed,disk 0
MCPC2 or MCPC2-A (NEMU) secondaryoperating system disk
MCPC2(-A), Secondary operating system disk has failed,disk 1
MCP18 or MCP18-B (NEMU) primary operatingsystem disk
MCP18(-B), Primary operating system disk has failed,disk 0
MCP18 or MCP18-B (NEMU) secondaryoperating system disk
MCP18(-B), Secondary operating system disk has failed,disk 1
Interface unit Replacing interface units
For more information on plug-in units, see Nokia Multimedia GatewayPlug-in Unit Descriptions or Nokia WCDMA Radio Network ControllerPlug-in Unit Descriptions in PDF format in NOLS. For general instructionson how to install plug-in units, see Installing plug-in units in Installing therMGW and RNC.
Caution
Electrostatic discharge and incorrect installation and uninstallation candamage circuits or shorten their lifetime. To ensure proper functioning ofthe plug-in units during their usual lifetime, take the followingprecautions before handling them:
. Before touching integrated circuits, ensure that you are working in anelectrostatic-free environment.
. Wear an ESD wrist strap or use another corresponding method todischarge static electricity in your body.
NI4S0, NI4S1-B, IPFGE and MDS-A plug-in units include CLASS 1LASER PRODUCT.
For more information on general environmental requirements, seeInstallation Site Requirements for MGW and RNC.
16 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Insert the plug-in unit carefully. It is important to check that the lockingscrews are closed properly, and that the plug-in unit is well in its place.
Before you start
Always check the interchangeability of the spare plug-in unit beforechanging the unit. You can check the interchangeability against theRevision List. The interchangeability sticker is located in the front panel ofthe plug-in unit after the C number. The interchangeability code of the newplug-in unit must be the same as or newer than the old plug-in unit's code.If the interchangeability code of the new plug-in unit is newer than the oldunit's code, check the effects on the interchangeability of the subrack andthe other plug-in units.
It is recommended that you maintain a log of spares so that you can traceany plug-in unit at any time.
Before removing or inserting a plug-in unit, all the functional units of theplug-in unit must be in the SE-NH state. For instructions, see Taking unitout of use.
Steps
1. Remove the faulty plug-in unit from the subrack
Note
The functional units of the plug-in unit must be in SE-NH state before aplug-in unit can be removed.
a. Remove the cable(s) from the front panel of the plug-in unit ifthere are any.
Some plug-in units have LAN or STM-1 cable(s) in the frontpanel.
b. Unscrew locking screws on the front panel of the plug-in unit.
Locking screws keep the plug-in unit in its place. The numberof locking screws depends on the type of the plug-in unit.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 17 (179)
Replacing plug-in unit with the same variant
Figure 4. Unscrewing locking screws
c. Open the two insertion/extraction levers on the front panel ofthe plug-in unit.
Insertion/extraction levers are locking clamps which securethe plug-in unit to the rack. Insertion/extraction levers arelocated on the upper and lower edge of the plug-in unit.
AllenkeyM2.5
DN02220548
18 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Figure 5. Opening locking clamps and removing plug-in unit
d. Remove the plug-in unit from the subrack.
1
1
2
DN70216177Issue 1-0 en
# Nokia Siemens Networks 19 (179)
Replacing plug-in unit with the same variant
2. Install the new plug-in unit into the subrack
If you are replacing a CCPC2–A plug-in unit, check the HMSMjumper block. Only the OMU unit can act as an HMS master. Formore information, see Jumper settings of CCPC2-A C100575 inNokia Multimedia Gateway Plug-in Unit Descriptions and NokiaRadio Network Controller Plug-in Unit Descriptions in PDF format inNOLS.
a. Close the insertion/extraction levers on the front panel of theplug-in unit.
Insertion/extraction levers are locking clamps which securethe plug-in unit to the rack. Insertion/extraction levers arelocated on the upper and lower edge of the plug-in unit.
b. Close the locking screws carefully.
Locking screws keep the plug-in unit in its place. The numberof locking screws depends on the type of the plug-in unit.
c. Insert cable(s) to the front panel of the plug-in unit if there areany.
Some plug-in units have LAN or STM-1 cable(s) in the frontpanel.
3. Check the compatibility of the HMS node SW version of theplug-in unit
See instructions in Checking the software version of the HMS node.
4. Check the data on the installed plug-in unit (WFL)
ZWFL:P:<cabinet hms number>,<subrack hms number>,<ppa>;
Verify that plug-in unit data is correct.
5. Set the functional units into SE-OU working state (USC)
ZUSC:<unit type>,<unit index>:SE;
6. Set the functional units into TE working state (USC)
ZUSC:<unit type>,<unit index>:TE;
Wait until all functional units have restarted.
Expected outcome
20 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
All the units in the hierarchy should now be in TE-EX working state.
Unexpected outcome
If the unit restart fails, contact your local Nokia Customer ServiceCenter.
7. Check the version of the flash memory boot package of theplug-in unit against the SW package (WDI)
You can check the boot package versions of all functional units of acertain type by giving the name of the functional unit (for example,NIWU) as the value for the unit type parameter.
ZWDI:UT=<unit type>,UI=<unit index>;
For more information on the boot package compatibility andexamples, see Checking and updating the boot package of acomputer unit in Software Configuration Management.
Expected outcome
If the flash memory boot packages are compatible, you cancontinue.
Unexpected outcome
If the flash memory boot packages are not compatible, you mustupdate the boot package. Follow the instructions in Checking andupdating the boot package of a computer unit in SoftwareConfiguration Management.
8. Check that the repair operation was successful by starting totaldiagnosis of the unit (UDU)
ZUDU:<unit type>,<unit index>;
For more information, see Diagnostics and testing.
9. Set the unit to normal working state (USC)
Depending on the redundancy principle of the unit, the normalworking state of the unit is SP-EX or WO-EX.
ZUSC:<unit type>,<unit index>:WO|SP;
DN70216177Issue 1-0 en
# Nokia Siemens Networks 21 (179)
Replacing plug-in unit with the same variant
10. Check that there are no on-state alarms for the functional unit(AAP)
ZAAP;
22 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
4 Replacing plug-in unit with newer variantPurpose
This procedure provides instructions for replacing a plug-in unit with anewer variant of the same plug-in unit.
Some plug-in units cannot be replaced using these instructions. TableReplacing plug-in units with newer variants gives a list of the plug-in unitsthat must be replaced according to instructions specified in the lattercolumn.
Tip
This procedure includes instructions for replacing CCPC2-A plug-inunits with CCP10. There are separate instructions for replacing OMUCCPC2-A plug-in units with OMU CCP10. For more information, seetable Replacing plug-in units with newer variants.
Table 6. Replacing plug-in units with newer variants
Old plug-in unit New plug-in unit See instructions in
CCPC2-A (OMU) CCP10 (OMU) Replacing CCPC2–A plug-in unit withCCP10 (OMU)
ESA12 ESA24 Replacing ESA12 plug-in unit withESA24
MCPC2 (NEMU) MCP18 or MCP18-B (NEMU) Replacing MCPC2 plug-in unit withMCP18(-B)
MCPC2-A (NEMU) MCP18 or MCP18-B (NEMU) Replacing MCPC2-A plug-in unit withMCP18(-B)
DN70216177Issue 1-0 en
# Nokia Siemens Networks 23 (179)
Replacing plug-in unit with newer variant
For more information on plug-in units, see either Nokia MultimediaGateway Plug-in Unit Descriptions or Nokia WCDMA Radio NetworkController Plug-in Unit Descriptions in PDF format in NOLS. For generalinstructions on how to install plug-in units, see Installing plug-in units inInstalling the MGW and RNC.
Insert the plug-in unit carefully. It is important to check that the lockingscrews are closed properly, and that the plug-in unit is well in its place.
Caution
Electrostatic discharge and incorrect installation and uninstallation candamage circuits or shorten their lifetime. To ensure proper functioning ofthe plug-in units during their usual lifetime, take the followingprecautions before handling them:
. Before touching integrated circuits, ensure that you are working in anelectrostatic-free environment.
. Wear an ESD wrist strap or use another corresponding method todischarge static electricity in your body.
For more information on general environmental requirements, seeInstallation Site Requirements for MGW and RNC.
When replacing a 2N redundant unit, you must replace both units. A mixed2N redundant unit configuration with an older and a newer variant of aplug-in unit is only allowed as a temporary solution during the replacementprocedure.
When replacing an N+1 redundant unit, you do not need to replace all theN+1 redundant units of the same plug-in unit variant. However, thecapacity of the more powerful plug-in unit variants in the unit group isalways limited to the level of the weakest plug-in unit variant.
Before you start
Check the interchangeability of the plug-in units from the Revision List. Ifyou are not sure about the interchangeability of the plug-in unit variants,please refer to the latest RNC or MGW HW Revision List available inNOLS.
24 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
It is recommended that you maintain a log of spares so that you can traceany plug-in unit at any time.
Before removing or inserting a plug-in unit, all the functional units of theplug-in unit must be in the SE-NH state. For instructions, see Taking unitout of use.
Steps
1. Remove the plug-in unit from the subrack
a. Remove the cable(s) from the front panel of the plug-in unit ifthere are any.
Some plug-in units have LAN or STM-1 cable(s) in the frontpanel.
b. Unscrew locking screws on the front panel of the plug-in unit.
Locking screws keep the plug-in unit in its place. The numberof locking screws depends on the type of the plug-in unit.
Figure 6. Unscrewing locking screws
AllenkeyM2.5
DN02220548
DN70216177Issue 1-0 en
# Nokia Siemens Networks 25 (179)
Replacing plug-in unit with newer variant
c. Open the two insertion/extraction levers on the front panel ofthe plug-in unit.
Insertion/extraction levers are locking clamps which securethe plug-in unit to the rack. Insertion/extraction levers arelocated on the upper and lower edge of the plug-in unit.
26 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Figure 7. Opening locking clamps and removing plug-in unit
d. Remove the plug-in unit from the subrack.
1
1
2
DN70216177Issue 1-0 en
# Nokia Siemens Networks 27 (179)
Replacing plug-in unit with newer variant
2. Delete the HW description data on the old plug-in unit
Follow the instructions in Deleting HW description data whenreplacing plug-in units.
3. Create the HW description data on the new plug-in unit
Follow the instructions in Creating HW description data whenreplacing plug-in units.
4. Install the plug-in unit into the subrack
a. If you are replacing a CCPC2-A plug-in unit with a CCP10 unit,remove the HMS jumpering if that is in place. HMS jumper isnot needed in CCP10.
b. Close the insertion/extraction levers on the front panel of theplug-in unit.
Insertion/extraction levers are locking clamps which securethe plug-in unit to the rack. Insertion/extraction levers arelocated on the upper and lower edge of the plug-in unit.
c. Close the locking screws carefully.
Locking screws keep the plug-in unit in its place. The numberof locking screws depends on the type of the plug-in unit.
d. Insert cable(s) to the front panel of the plug-in unit if there areany.
Some plug-in units have LAN or STM-1 cable(s) in the frontpanel.
5. Set the functional units into SE-OU working state (USC)
ZUSC:<unit type>,<unit index>:SE;
6. Set the functional units into TE working state (USC)
ZUSC:<unit type>,<unit index>:TE;
Wait until all functional units have restarted.
Expected outcome
All the units in the hierarchy should now be in TE-EX working state.
Unexpected outcome
If the unit restart fails, contact your local Nokia Customer ServiceCenter.
28 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
7. Check the version of the flash memory boot package of theplug-in unit against the SW package (WDI)
You can check the boot package versions of all functional units of acertain type by giving the name of the functional unit (for example,NIWU) as the value for the unit type parameter.
ZWDI:UT=<unit type>,UI=<unit index>;
For more information on the boot package compatibility andexamples, see Checking and updating the boot package of acomputer unit in Software Configuration Management.
Expected outcome
If the flash memory boot packages are compatible, you cancontinue.
Unexpected outcome
If the flash memory boot packages are not compatible, you mustupdate the boot package. Follow the instructions in Checking andupdating the boot package of a computer unit in SoftwareConfiguration Management.
8. Check that the repair operation was successful by starting totaldiagnosis of the unit (UDU)
ZUDU:<unit type>,<unit index>;
For more information, see Diagnostics and testing.
9. Set the unit to WO or SP working state (USC)
Depending on the redundancy principle of the unit, set the unitworking state to WO-EX (SN+ units) or SP-EX (2N or N+1 units).
ZUSC:<unit type>,<unit index>:WO|SP;
10. Check that there are no on-state alarms for the functional unit(AAP)
ZAAP;
11. If the unit you are replacing is 2N redundant, or if you want to changeall the N+1 units at the same time
DN70216177Issue 1-0 en
# Nokia Siemens Networks 29 (179)
Replacing plug-in unit with newer variant
Then
Make a unit switchover and replace the spare unit (USC)
Note
A mixed 2N pair with an older and newer variant does not maintain fullinput synchronism. For this reason new calls may fail but ongoing callsshould remain during the switchover.
. When replacing a 2N unit, change the working state of thespare unit to WO-EX.
ZUSC:<unit type>,<unit index>:WO;. When replacing an N+1 unit, change the working state of the
next unit in WO-EX state to SP. The N+1 unit in SP-EX statemust be a newer variant.
ZUSC:<unit type>,<unit index>:SP;
Replace the spare unit of the 2N redundant unit or, in case of an N+1redundant unit, the other N+1 units with newer variants.
30 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
5 Replacing CCPC2–A plug-in unit withCCP10 (OMU)
Purpose
This procedure provides instructions for replacing a CCPC2–A plug-in unitwith CCP10 when that unit is OMU. Because OMU is a 2N redundant unit,you must replace both the active and the spare unit. A mixed CCPC2–Aand CCP10 2N redundant unit configuration is only allowed as atemporary solution.
For replacing another CCPC2-A unit than OMU, see instructions inReplacing plug-in unit with newer variant.
For more information on plug-in units, see either Nokia MultimediaGateway Plug-in Unit Descriptions or Nokia WCDMA Radio NetworkController Plug-in Unit Descriptions in PDF format in NOLS. For generalinstructions on how to install plug-in units, see Installing plug-in units inInstalling the MGW and RNC.
Caution
Electrostatic discharge and incorrect installation and uninstallation candamage circuits or shorten their lifetime. To ensure proper functioning ofthe plug-in units during their usual lifetime, take the followingprecautions before handling them:
. Before touching integrated circuits, ensure that you are working in anelectrostatic-free environment.
. Wear an ESD wrist strap or use another corresponding method todischarge static electricity in your body.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 31 (179)
Replacing CCPC2–A plug-in unit with CCP10 (OMU)
For more information on general environmental requirements, seeInstallation Site Requirements for MGW and RNC.
Insert the plug-in unit carefully. It is important to check that the lockingscrews are closed properly, and that the plug-in unit is well in its place.
Before you start
Check the interchangeability of the plug-in units from the Revision List. Ifyou are not sure about the interchangeability of the plug-in unit variants,please refer to the latest RNC or MGW HW Revision List available inNOLS.
The upgrade set includes the hardware needed in the upgrade. Check thatyou have the following:
. one temporary cable for the upgrade (CJGA), needed because ofswitching between I/O devices
. one MDS-A plug-in unit and adapter
. two CCP10 plug-in units and 1-4 GB memory
Both units need 512 MB - 2 GB of memory. Both units must have thesame amount of memory.
. two HDS-A plug-in units and adapters
. two LAN cables for both OMU units (CA_130, CA_131, CA_138, andCA_139), type CHUS for ESA12 and CHES for ESA24
. 15 SCSI cables (CA_075 - CA_089), type CHS
Also create a fallback copy of the software build before starting theupgrade.
Note
Returning to the previously used HW/SW level is not possible after thesuccessful completion of the upgrade.
32 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Note
Before removing or inserting a plug-in unit, both CCPC2-As and all theother units which are connected to the OMU must be in the SE-NHstate. For instructions, see Taking unit out of use.
Steps
1. Set SCSI bus 0 to SE-NH state (IHE)
a. Set SCSI bus 0 to TE-EX state.
ZIHE:OMU:SCSI,0:TE;
b. Set SCSI bus 0 to SE-OU state.
ZIHE:OMU:SCSI,0:SE;
c. Set SCSI bus 0 to SE-NH state.
ZIHE:OMU:SCSI,0:SE;
2. Remove the CCPC2-A plug-in unit (OMU-1) from the subrack
a. Remove the LAN cables from the front panel of the plug-inunit.
b. Unscrew locking screws on the front panel of the plug-in unit.
Locking screws keep the plug-in unit in its place. The numberof locking screws depends on the type of the plug-in unit. SeeFigure Unscrewing locking screws in Replacing plug-in unitwith newer variant.
c. Open the two insertion/extraction levers on the front panel ofthe plug-in unit.
Insertion/extraction levers are locking clamps which securethe plug-in unit to the rack. Insertion/extraction levers arelocated on the upper and lower edge of the plug-in unit. SeeFigure Opening locking clamps and removing plug-in unit inReplacing plug-in unit with newer variant.
d. Remove the plug-in unit from the subrack.
3. Delete the HW description data on CCPC2-A (OMU-1)
Delete the functional unit description for OMU-1 and the portconnections and plug-in unit description of CCPC2-A. Follow theinstructions in Deleting HW description data when replacing plug-inunits.
4. Delete the HW description data on the old disk drives
Perform the following actions for both MDS-0 and WDU-0:
DN70216177Issue 1-0 en
# Nokia Siemens Networks 33 (179)
Replacing CCPC2–A plug-in unit with CCP10 (OMU)
a. Delete and detach the functional unit description. Forinstructions, see Deleting and detaching functional unitdescription.
b. Delete the plug-in unit description. For instructions, seeDeleting plug-in unit description.
5. Remove the old SCSI components
Note
Remove the CCPC2-A plug-in unit (OMU-1) from the subrack beforeremoving the SCSI components.
Remove the following:. WDU-0. MDS-0. All SCSI cables of bus 0. The SCSI cable between OMU-1 and WDU-1
For detailed information, see Cable Lists in Site documents.
6. Install the temporary SCSI cable (CJGA) between OMU-1 andWDU-1
The following tables shows the cable locations:
Table 7. CJGA cable between OMU-1 and WDU-1
OMU-1 Connector WDU-1 Connector
1.0 2.0B 16.5H 3 1.0 2.0B 3W 1
1.0 2.0B 16.5O 4 1.0 2.0B 4C 2
1.0 2.0B 16.5U 5
7. Create the HW description data on the new disk drives
Perform the following actions for MDS-0:
34 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
a. Create plug in unit description for MDS-A. For instructions, seeCreating plug-in unit description.
b. Create and attach the functional unit description. Forinstructions, see Creating and attaching functional unitdescription.
Perform the following actions for WDU-0:
a. Create plug in unit description for HDS-A. For instructions, seeCreating plug-in unit description.
b. Create and attach the functional unit description. Forinstructions, see Creating and attaching Hard Disk Drive(WDU) description.
Perform the following actions for WDU-1:
a. Create plug in unit description for HDS-A. For instructions, seeCreating plug-in unit description.
b. Create and attach the functional unit description. Forinstructions, see Creating and attaching Hard Disk Drive(WDU) description.
8. Create the HW description data on CCP10
Create the plug-in unit description for CCP10, connect the ports forCCP10, and create and attach the OMU-1 functional unit. Note thatyou cannot check the software version of the HMS node before youhave installed the plug-in unit.
Note that the SCSI port locations are different in CCP10 and inCCPC2-A.
Follow the instructions in Creating HW description data whenreplacing plug-in units.
9. Install the CCP10 plug-in unit into the subrack
Note
Create the HW description data on CCP10 plug-in unit before installingit.
a. Before inserting CCP10 into to the subrack, install the HMSmaster net cables to the new position.
b. Remove the HMS jumpering if that is in place. HMS jumper isnot needed in CCP10.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 35 (179)
Replacing CCPC2–A plug-in unit with CCP10 (OMU)
c. Close the insertion/extraction levers on the front panel of theplug-in unit.
Insertion/extraction levers are locking clamps which securethe plug-in unit to the rack. Insertion/extraction levers arelocated on the upper and lower edge of the plug-in unit.
d. Close the locking screws carefully.
Locking screws keep the plug-in unit in its place. The numberof locking screws depends on the type of the plug-in unit.
e. Insert LAN cables to the back panel of the plug-in unit.
10. Check the software version of the HMS node of CCP10
For instructions, see Checking the software version of the HMSnode.
11. Set OMU-1 into SE-OU working state (USC)
ZUSC:OMU,1:SE;
12. Set OMU-1 into TE working state (USC)
ZUSC:OMU,1:TE;
Wait until the unit has restarted. If the restart fails, contact your localNokia Customer Service Center.
13. Check the version of the CCP10 flash memory boot packageagainst the software package (WDI)
ZWDI:UT=OMU,UI=1;
For more information on the boot package compatibility andexamples, see Checking and updating the boot package of acomputer unit in Software Configuration Management.
Expected outcome
If the flash memory boot packages are compatible, you cancontinue.
Unexpected outcome
If the flash memory boot packages are not compatible, you mustupdate the boot package. Follow the instructions in Checking andupdating the boot package of a computer unit in SoftwareConfiguration Management.
36 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
14. Check that the repair operation was successful by starting totaldiagnosis of OMU-1 (UDU)
ZUDU:OMU,1;
For more information, see Diagnostics and testing.
15. Set OMU-1 to SP working state (USC)
ZUSC:OMU,1:SP;
16. Check that there are no on-state alarms for OMU-1 (AAP)
ZAAP;
17. Make the unit switchover (USC)
Only one switchover is allowed for OMU units.
Note
A mixed 2N pair with an older and newer variant does not maintain fullinput synchronism. For this reason new calls may fail but ongoing callsshould remain during the switchover.
ZUSC:OMU,1:WO;
18. Repeat steps 2-4 for OMU-0
Remove the OMU-0 CCPC2-A from the subrack. Delete the HWdescription data for the CCPC2-A and OMU-0.
19. Remove the SCSI cable between OMU-0 and WDU-1
20. Install the new SCSI cables for bus 0
Install the SCSI cables between OMU-0, WDU-0, MDS-0, and OMU-1.
21. Move the disk drive and the FDU drive into the new plug-in units
Move the disk drive of WDU-0 into the HDS-A plug-in unit and theMDS-0 into the MDS-A plug-in unit. Insert the new plug-in units intothe subrack.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 37 (179)
Replacing CCPC2–A plug-in unit with CCP10 (OMU)
22. Set SCSI bus 0 to WO-EX state (IHE)
a. Set SCSI bus 0 to SE-OU state.
ZIHE:OMU:SCSI,0:SE;
b. Set SCSI bus 0 to TE-EX state.
ZIHE:OMU:SCSI,0:TE;
c. Set SCSI bus 0 to WO-EX state.
ZIHE:OMU:SCSI,0:WO;
Wait until both WDU-0 and MDS-0 on SCSI bus 0 also change intoWO-EX and the mirroring completes. You can check the states withthe following command:
ZIHI:OMU:WDU;
If the mirroring is not complete, the states show the MIR and LCKflags.
If the states of WDU-0 and MDS-0 do not change to WO-EX, changethe states manually.
23. Set SCSI bus 1 to SE-NH state (IHE)
a. Set SCSI bus 0 to TE-EX state.
ZIHE:OMU:SCSI,1:TE;
b. Set SCSI bus 0 to SE-OU state.
ZIHE:OMU:SCSI,1:SE;
c. Set SCSI bus 0 to SE-NH state.
ZIHE:OMU:SCSI,1:SE;
24. Remove the temporary SCSI cable (CJGA) and the WDU-1 plug-in unit
25. Install the new SCSI cables for SCSI bus 1
Install the SCSI cables between OMU-0, WDU-1, and OMU-1.
26. Move the disk drive into the new plug-in unit
Move the disk drive of WDU-1 into the HDS-A plug-in unit. Insert thenew plug-in units into the subrack.
27. Set SCSI bus 1 to WO-EX state (IHE)
a. Set SCSI bus 1 to SE-OU state.
ZIHE:OMU:SCSI,1:SE;
38 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
b. Set SCSI bus 1 to TE-EX state.
ZIHE:OMU:SCSI,1:TE;
c. Set SCSI bus 1 to WO-EX state.
ZIHE:OMU:SCSI,1:WO;
Wait until WDU-1 on SCSI bus 1 also changes into WO-EX and themirroring completes. You can check the state with the followingcommand:
ZIHI:OMU:WDU;
If the mirroring is not complete, the state shows the MIR and LCKflags.
If the state of WDU-1 does not change to WO-EX, change the statemanually.
28. Repeat steps 8 - 15 for the other CCP10 plug-in unit (OMU-0)
29. Delete the old software packages
Delete the SW packages that are not needed anymore. Switchingover to the previously used HW/SW level is not possible after theupgrade.
30. Create a fallback copy of the new software package
DN70216177Issue 1-0 en
# Nokia Siemens Networks 39 (179)
Replacing CCPC2–A plug-in unit with CCP10 (OMU)
40 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
6 Replacing ESA12 plug-in unit withESA24
Purpose
This procedure shows how to replace an ESA12 plug-in unit with ESA24.
For more information on plug-in units and cables and general instructionson how to install plug-in units, see Installing the MGW and RNC.
Note that the equipment database does not recognise ESA12 or ESA24,and it does not have working states.
Caution
Electrostatic discharge and incorrect installation and uninstallation candamage circuits or shorten their lifetime. To ensure proper functioning ofthe plug-in units during their usual lifetime, take the followingprecautions before handling them.
. Before touching integrated circuits, ensure that you are working in anelectrostatic-free environment.
. Wear an ESD wrist strap or use another corresponding method todischarge static electricity in your body.
For more information on general environmental requirements, seeInstallation Site Requirements for MGW and RNC.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 41 (179)
Replacing ESA12 plug-in unit with ESA24
Note
Insert the plug-in unit carefully. It is important to check that the lockingscrews are closed properly, and that the plug-in unit is well in its place.
Before you start
If you are not sure about the interchangeability of the plug-in unit variants,please refer to the latest MGW HW Revision List available in NOLS.
It is recommended that you maintain a log of spares so that you can traceany plug-in unit at any time.
You need to block the alarm 3053 (ETHERNET INTERFACE FAILURE)before replacing the unit and unblock it after you have replaced the unit.
1. Block the alarm 3053.
AFB:3053::RES::;
2. Change the plug-in unit as described in the steps 1-13.
3. After changing the plug-in unit, unblock the alarm 3053.
ZAFU:3053::;.
Steps
1. Remove the LAN cable(s) from the front panel of ESA12
Table 8. LAN cables to be removed from ESA12 when plug-in unit for OMU isCCP10 in MGW
Equip.
No
CABLE FROM CABLE TO Type Use
FU Position/Conn.
FU Position/Conn.
CA_130 ESA12 1.0F 12.ETH 3 OMU 0 1.0B 16.3B CHUS012 LAN 1)
CA_131 ESA12 1.0F 12.ETH 4 OMU 1 2.0B 16.3B CHUS012 LAN 1)
CA_132 ESA12 1.0F 12.ETH 5 NEMU/
MCP18(-B)
1.0B 13.3B CHUS048 LAN
NEMU/
MCPC2(-A)
1.0F 13.ETH 1 CNI006
1) Cabling from bottom
42 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Table 9. LAN cables to be removed from ESA12 when plug-in unit for OMU isCCPC2–A in MGW
Equip.
No
CABLE FROM CABLE TO Type Use
FU Position/Conn.
FU Position/Conn.
CA_130 ESA12 1.0F 12.ETH3 OMU 0 1.0F 16.ETH CNI007 LAN
CA_131 ESA12 1.0F 12.ETH4 OMU 1 2.0F 16.ETH CNI012 LAN
CA_132 ESA12 1.0F 12.ETH5 NEMU/
MCP18(-B)
1.0B 13.3B CHUS048 LAN
NEMU/
MCPC2(-A)
1.0F 13.ETH1 CNI006
2. Unscrew the locking screws on the front panel of ESA12
Table 10. ESA12 to be removed
Position ID Name FU
Subrack 1
F12 C72490 ESA12 (NEMU)
Locking screws keep the plug-in unit in its place. Locking screws arelocated on top of the insertion/extraction levers. See FigureUnscrewing locking screws in Replacing plug-in unit with newervariant.
3. Open insertion/extraction levers on the front panel of ESA12
Insertion/extraction levers are locking clamps which secure the plug-in unit to the rack. Insertion/extraction levers are located on theupper and lower edge of the plug-in unit. See Figure Opening lockingclamps and removing plug-in unit in Replacing plug-in unit withnewer variant.
4. Double-click (within two seconds) the reset switch in the frontpanel of ESA12
DN70216177Issue 1-0 en
# Nokia Siemens Networks 43 (179)
Replacing ESA12 plug-in unit with ESA24
The electricity switches off from the unit. There is no light in the LEDlight which is in the front panel of the ESA12 plug-in unit.
The electricity will be off for 20 seconds.
5. Remove ESA12 from the subrack within 20 seconds
If you do not remove the unit within 20 seconds, the unit willautomatically restart itself.
6. Install new cabling for ESA24
ESA24 has cables in the back side of the subrack.
Table 11. ESA24 LAN cables for ISU use (in MGW)
Equip.
No
CABLE FROM CABLE TO Type Use
FU Conn. FU Conn.
CA_135 ESA24 0 1.0B 12.4J ISU 0 2.0B 3.3B CHES015 LAN
CA_136 ESA24 0 1.0B 12.4P ISU 1 3.0B 16.3B CHES013 LAN
CA_137 ESA24 0 1.0B 12.4R ISU 2 4.0B 16.3B CHES023 LAN
CB0_135 ISU 3 1.0B 16.3 B ESA24 0 1.0B 12.4T CHES020 LAN
CB0_136 ISU 4 2.0B 16.3 B ESA24 0 1.0B 12.4V CHES022 LAN
CB0_137 ISU 5 3.0B 16.3 B ESA24 0 1.0B 12.4X CHES026 LAN
CB0_138 ISU 6 4.0B 16.3 B ESA24 0 1.0B 12.4Z CHES030 LAN
CC0_135 ISU 7 1.0B 16.3 B ESA24 0 1.0B 12.5B CHES032 LAN
CC0_136 ISU 8 2.0B 16.3 B ESA24 0 1.0B 12.5D CHES034 LAN
CC0_137 ISU 9 3.0B 16.3 B ESA24 0 1.0B 12.5F CHES038 LAN
CC0_138 ISU 10 4.0B 16.3 B ESA24 0 1.0B 12.5H CHES042 LAN
CA_140 ESA24 1 3.0B 13.4J ISU 0 2.0B 3.3D CHES006 LAN
CA_141 ESA24 1 3.0B 13.4P ISU 1 3.0B 16.3D CHES006 LAN
CA_142 ESA24 1 3.0B 13.4R ISU 2 4.0B 16.3D CHES013 LAN
CB0_139 ISU 3 1.0B 16.3D ESA24 1 3.0B 13.4T CHES026 LAN
CB0_140 ISU 4 2.0B 16.3D ESA24 1 3.0B 13.4V CHES022 LAN
CB0_141 ISU 5 3.0B 16.3D ESA24 1 3.0B 13.4X CHES018 LAN
44 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Table 11. ESA24 LAN cables for ISU use (in MGW) (cont.)
Equip.
No
CABLE FROM CABLE TO Type Use
FU Conn. FU Conn.
CB0_142 ISU 6 4.0B 16.3D ESA24 1 3.0B 13.4Z CHES022 LAN
CC0_139 ISU 7 1.0B 16.3D ESA24 1 3.0B 13.5B CHES036 LAN
CC0_140 ISU 8 2.0B 16.3D ESA24 1 3.0B 13.5D CHES032 LAN
CC0_141 ISU 9 3.0B 16.3D ESA24 1 3.0B 13.5F CHES028 LAN
CC0_142 ISU 10 4.0B 16.3D ESA24 1 3.0B 13.5H CHES032 LAN
Table 12. ESA24 LAN cables to be installed when plug-in unit for OMU isCCP10 (in MGW)
Equip.
No
CABLE FROM CABLE TO Type Use
FU Conn. FU Conn.
CA_130 ESA24 0 1.0B 12.4C OMU 0 1.0B 16.3B CHES006 LAN
CA_131 ESA24 0 1.0B 12.4E OMU 1 2.0B 16.3B CHES012 LAN
CA_138 ESA24 1 3.0B 13.4C OMU 0 1.0B 16.3D CHES018 LAN
CA_139 ESA24 1 3.0B 13.4E OMU 1 2.0B 16.3D CHES012 LAN
CA_132 ESA24 0 1.0B 12.4G NEMU/
MCP18
1.0B 13.3B CHES006 LAN
NEMU 0/
MCP2(-A)
1.0F 13.ETH1 CHUS048
CA_133 ESA24 1 3.0B 13.4G NEMU/
MCP18
1.0B 13.3D CHES014 LAN
NEMU/
MCP2(-A)
1.0F 13.ETH2 CHUS040
DN70216177Issue 1-0 en
# Nokia Siemens Networks 45 (179)
Replacing ESA12 plug-in unit with ESA24
Table 13. ESA24 LAN cables to be installed when plug-in unit for OMU isCCPC2–A (in MGW)
Equip.
No
CABLE FROM CABLE TO Type Use
FU Conn. FU Conn.
CA_130 ESA 24 0 1.0B 12.4C OMU 0 1.0F 16.ETH1 CHUS012 LAN
CA_131 ESA 24 0 1.0B 12.4E OMU 1 2.0F 16.ETH1 CHUS012 LAN
CA_132 ESA 24 0 1.0B 12.4G NEMU/
MCP18
1.0B 13.3B CHES006 LAN
NEMU/
MCP2(-A)
1.0F 13.ETH1 CHUS048
CA_133 ESA 24 1 3.0B 13.4G NEMU/
MCP18
1.0B 13.3D CHES014 LAN
NEMU/
MCP2(-A)
1.0F 13.ETH2 CHUS040
Note
Before cabling, remember to activate STP/RSTP/MSTP according tothe planned resiliency method. Alternatively, remove the factoryattached cable. See IP connection configuration documentation formore information.
Table 14. ESA24 LAN cable between Ethernet switches (in MGW)
Equip.
No
CABLE FROM CABLE TO Type Use
FU Conn. FU Conn.
CA_134 ESA 24 1 3.0B 13.5K ESA24 0 1.0B 12.5K CHES018 LAN (MGW)
7. Install terminators (ADMOD address modules) for ESA24
46 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Table 15. Address setting modules to be installed for ESA24 (in MGW)
Position ID Name FU Use
1.0B 12.1S C108585 ADMOD01 ESA24 Cabinet address settingmodule
1.0B 12.1U C108585 ADMOD01 ESA24 Subrack address settingmodule
3.0B 13.1S C108585 ADMOD01 ESA24 Cabinet address settingmodule
3.0B 13.1U C108690 ADMOD03 ESA24 Subrack address settingmodule
8. Insert ESA24 in its location
Table 16. ESA24 to be installed
Position ID Name FU
Subrack 1
F12 C108427 ESA24 (NEMU)
9. Close the insertion/extraction levers on the front panel ofESA24
10. Close the locking screws carefully
11. Configure ESA24
You have to configure the ESA24 unit before taking it into use. Forinstructions, see Configuring ESA24 in IP Connection Configurationfor MGW.
12. Insert the LAN cable(s) to the front panel of ESA24
13. Configure or upgrade the ESA24 software
For more information, see section Upgrading ESA24 software inSoftware Configuration Management and the ESA24 User Guide.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 47 (179)
Replacing ESA12 plug-in unit with ESA24
48 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
7 Replacing MCPC2 plug-in unit withMCP18(-B)
Purpose
This procedure provides instructions for replacing an MCPC2 plug-in unit(NEMU) that is used with HDS/HDS9/HDS-A plug-in units with MCP18 orMCP18-B (NEMU) that is used with HDS-A plug-in units.
Note
NEMU software must be re-installed after replacing the MCPC2 plug-inunit with MCP18(-B), because of new hardware architecture in the newNEMU plug-in unit. Instructions are available from the SoftwareDelivery service in NOLS or from your local Nokia Customer ServiceCenter.
For more information on plug-in units and cables, see either NokiaMultimedia Gateway Plug-in Unit Descriptions and Cable Lists for MGW orNokia WCDMA Radio Network Controller Plug-in Unit Descriptions andCable Lists for RNC in PDF format in NOLS. For general instructions onhow to install plug-in units, see Installing plug-in units in Installing theMGW and RNC.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 49 (179)
Replacing MCPC2 plug-in unit with MCP18(-B)
Caution
Electrostatic discharge and incorrect installation and uninstallation candamage circuits or shorten their lifetime. To ensure proper functioning ofthe plug-in units during their usual lifetime, take the followingprecautions before handling them.
. Before touching integrated circuits, ensure that you are working in anelectrostatic-free environment.
. Wear an ESD wrist strap or use another corresponding method todischarge static electricity in your body.
For more information on general environmental requirements, seeInstallation Site Requirements for MGW and RNC.
Note that the equipment database does not recognise MCPC2, MCP18 orMCP18-B, and they do not have working states.
Before you start
If you are not sure about the interchangeability of the plug-in unit variants,please refer to the latest RNC or MGW HW Revision List available inNOLS.
It is recommended that you maintain a log of spares so that you can traceany plug-in unit at any time.
When replacing the MCPC2 (NEMU) plug-in unit with the MCP18 orMCP18-B plug-in unit, you must also replace the two HDS plug-in units(HDD 0 and HDD 1) with HDS-A plug-in units.
Steps
1. Shut down NEMU by selecting Shut down from the Start menu
When the Shut Down Windows message appears, select Shut downand confirm this by clicking OK in the dialog box.
2. Wait until the message appears that it is now safe to turn offyour computer
50 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
3. Remove the LAN cable(s) from the front panel of the MCPC2(NEMU) and the front panel of ESA12 or the back panel of theESA24 plug-in units and, if necessary, tie the cable(s) to thecable-shelf
Table 17. LAN cables to remove when MCPC2 is in use
Equip.No
CABLE FROM CABLE TO Type Use
FU Position/Conn. FU Position/Conn.
RNC:
CA_132 ESA 12 1.0F 12.ETH 5 NEMU/MCPC2
1.0F 13 ETH 1 CNI006 LAN(RNC)
ESA 24 1.0B 12.4G NEMU/MCPC2
1.0F 13 ETH 1 CHUX048 LAN 1)(RNC)
MGW:
CA_132 ESA 12 1.0F 12.ETH 5 NEMU/MCPC2
1.0F 13 ETH 1 CNI006 LAN(MGW)
ESA 24 0 1.0B 12.4G NEMU/MCPC2
1.0F 13 ETH 1 CHUS048 LAN 1)(MGW)
CA_133 ESA 24 1 3.0B 13.4G NEMU/MCPC2
1.0F 13 ETH 2 CHUS040 LAN 1)(MGW)
1) Cabling from the bottom, tie the cable(s) to the cable shelf
4. Remove the MCPC2 (NEMU) plug-in unit
a. Unscrew locking screws on the front panel of the plug-in unit.
Locking screws keep the plug-in unit in its place. The numberof locking screws depends on the type of the plug-in unit. SeeFigure Unscrewing locking screws in Replacing plug-in unitwith newer variant.
b. Open the two insertion/extraction levers on the front panel ofthe plug-in unit.
Insertion/extraction levers are locking clamps which securethe plug-in unit to the rack. Insertion/extraction levers arelocated on the upper and lower edge of the plug-in unit. SeeFigure Opening locking clamps and removing plug-in unit inReplacing plug-in unit with newer variant.
c. Double click (within two seconds) the reset switch in the frontpanel of MCPC2.
The electricity switches off. There is no light in the LED lightwhich is in the front panel of the plug-in unit.
The electricity will be off for 20 seconds.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 51 (179)
Replacing MCPC2 plug-in unit with MCP18(-B)
d. Remove the plug-in unit from the subrack.
The MCPC2 plug-in unit must be removed from the subrackwithin 20 seconds, or it will automatically restart itself.
5. Remove SCSI cabling between the MCPC2 (NEMU) and the HDS(HDD) plug-in units
The cables are located in the back panel of the subrack.
Table 18. SCSI cables to remove when MCPC2 (NEMU) and HDS are in use(RNC and MGW)
Equip.No.
CABLE FROM CABLE TO Type Use
FU Conn. FU Conn.
CA_030 NEMU 1.0B 13.4P HDD 0 (NEMU) 1.0B 14.3Q CJA002 SCSI bus
CA_031 NEMU 1.0B 13.4C HDD 0 (NEMU) 1.0B 14.3H CJB002 SCSI bus
CA_032 HDD 0 (NEMU) 1.0B 14.3W HDD 1 (NEMU) 2.0B 14.3H CJA005 SCSI bus
CA_033 HDD 0 (NEMU) 1.0B 14.4C HDD 1 (NEMU) 2.0B 14.3O CJB005 SCSI bus
6. Insert LAN cable(s) to the back panel of the MCP18(-B) (NEMU)and the front panel of ESA12 or the back panel of the ESA24plug-in units
For information on the routing of the cables, see Cable List for RNCand Cable Lists for MGW in site documents.
Table 19. LAN cables to install with MCP18(-B)
Equip.No
CABLE FROM CABLE TO Type Use
FU Position/Conn.
FU Position/Conn.
RNC:
CA_132 ESA 12 1.0F 12.ETH 5 NEMU/MCP18-B
1.0B 13.3B CHUS048 LAN(RNC)
ESA 24 1.0B 12.4G NEMU/MCP18-B
1.0B 13.3B CHES006 LAN(RNC)
MGW:
52 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Table 19. LAN cables to install with MCP18(-B) (cont.)
Equip.No
CABLE FROM CABLE TO Type Use
FU Position/Conn.
FU Position/Conn.
CA_132 ESA 12 1.0F 12.ETH 5 NEMU/MCP18 1.0B 13.3B CHUS048 LAN(MGW)
ESA 24 0 1.0B 12.4G NEMU/MCP18 1.0B 13.3B CHES006 LAN(MGW)
CA_133 ESA 24 1 3.0B 13.4G NEMU/MCP18 1.0B 13.3D CHES018 LAN(MGW)
7. Install the new SCSI cabling between MCP18(-B) (NEMU) andthe HDS-A (HDD) plug-in units
Table 20. SCSI cables to install when MCP18(-B) (NEMU) and HDS-A are inuse (RNC and MGW)
Equip.No.
CABLE FROM CABLE TO Type Use
FU Conn. FU Conn.
RNC and MGW:
CA_090 NEMU 1.0B 13.4P HDD 0(NEMU)
1.0B 14.3F CHS004 SCSI bus 0
CA_091 NEMU 1.0B 13.4V HDD 0(NEMU)
1.0B 14.3M CHS004 SCSI bus 0
CA_092 NEMU 1.0B 13.5B HDD 0(NEMU)
1.0B 14.3S CHS004 SCSI bus 0
CA_093 NEMU 1.0B 13.5H HDD 1(NEMU)
2.0B 14.3F CHS010 SCSI bus 1
CA_094 NEMU 1.0B 13.5O HDD 1(NEMU)
2.0B 14.3M CHS010 SCSI bus 1
CA_095 NEMU 1.0B 13.5U HDD 1(NEMU)
2.0B 14.3S CHS010 SCSI bus 1
8. Remove the two HDS (HDD 0 and HDD 1) plug-in units from thesubrack
DN70216177Issue 1-0 en
# Nokia Siemens Networks 53 (179)
Replacing MCPC2 plug-in unit with MCP18(-B)
Note
Mark the plug-in units so that you know which is HDD 0 and which isHDD 1.
a. Unscrew locking screws on the front panel of the plug-in units.Locking screws keep the plug-in unit in its place. The numberof locking screws depends on the type of the plug-in unit. Formore information see figure Unscrewing locking screws inReplacing plug-in unit with newer variant.
b. Open the two insertion/extraction levers on the front panel ofthe plug-in units. Insertion/extraction levers are locking clampswhich secure the plug-in unit to the rack. Insertion/extractionlevers are located on the upper and lower edge of the plug-inunit. For more information see figure Opening locking clampsand removing plug-in unit in Replacing plug-in unit with newervariant.
c. Remove the plug-in units from the subrack.
9. Remove hard disks from the HDS plug-in units
a. Remove the power cables and SCSI cables from the HDSplug-in unit.
b. Open the cross-point screws. The hard disk is attached to theHDS with four recessed head screws.
10. Install hard disks to the HDS-A plug-in units
a. Attach the hard disks to the HDS-A plug-in units with cross-point screws.
b. Insert the power cables and SCSI cables to the HDS-A plug-inunit.
11. Install the MCP18 or MCP18-B (NEMU) plug-in unit and the twoHDS-A (HDD) plug-in units into the subrack
Note
Insert the plug-in unit carefully. It is important to check that the lockingscrews are closed properly, and that the plug-in unit is well in its place.
54 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Note
Do not reverse the position of the HDD 0 and HDD 1. Keep the disks inthe same order as they were when using the MCPC2 plug-in unit.
a. Close the insertion/extraction levers on the front panel of theplug-in units.
Insertion/extraction levers are locking clamps which securethe plug-in units to the rack. Insertion/extraction levers arelocated on the upper and lower edge of the plug-in unit.
b. Close the locking screws carefully.
Locking screws keep the plug-in units in its place. The numberof locking screws depends on the type of the plug-in unit.
12. Re-install NEMU software
For instructions on installing NEMU software, see the SoftwareDelivery service in NOLS or contact your local Nokia CustomerService Center.
13. Note down the change of the plug-in unit variant
Note down in Equipment Lists in Site Documentation when you havereplaced a plug-in unit with a newer variant.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 55 (179)
Replacing MCPC2 plug-in unit with MCP18(-B)
56 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
8 Replacing MCPC2-A plug-in unit withMCP18(-B)
Purpose
This procedure provides instructions for replacing an MCPC2-A plug-inunit (NEMU) that is used with HDS/HDS9/HDS-A plug-in units with MCP18or MCP18-B (NEMU) that is used with HDS-A plug-in units.
Note
NEMU software must be re-installed after replacing the MCPC2-A plug-in unit with MCP18(-B), because of new hardware architecture in thenew NEMU plug-in unit. Instructions are available from the SoftwareDelivery service in NOLS or from your local Nokia Customer ServiceCenter.
For more information on plug-in units and cables, see either NokiaMultimedia Gateway Plug-in Unit Descriptions and Cable Lists for MGW orNokia WCDMA Radio Network Controller Plug-in Unit Descriptions andCable Lists for RNC in PDF format in NOLS. For general instructions onhow to install plug-in units, see Installing plug-in units in Installing theMGW and RNC.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 57 (179)
Replacing MCPC2-A plug-in unit with MCP18(-B)
Caution
Electrostatic discharge and incorrect installation and uninstallation candamage circuits or shorten their lifetime. To ensure proper functioning ofthe plug-in units during their usual lifetime, take the followingprecautions before handling them.
. Before touching integrated circuits, ensure that you are working in anelectrostatic-free environment.
. Wear an ESD wrist strap or use another corresponding method todischarge static electricity in your body.
For more information on general environmental requirements, seeInstallation Site Requirements for MGW and RNC.
Note that the equipment database does not recognise MCPC2-A, MCP18or MCP18-B, and they do not have working states.
Before you start
If you are not sure about the interchangeability of the plug-in unit variants,please refer to the latest RNC or MGW HW Revision List available inNOLS.
It is recommended that you maintain a log of spares so that you can traceany plug-in unit at any time.
Steps
1. Shut down NEMU by selecting Shut down from the Start menu
When the Shut Down Windows message appears, select Shut downand confirm this by clicking OK in the dialog box.
2. Wait until the message appears that it is now safe to turn offyour computer
3. Remove the LAN cable(s) from the front panel of the MCPC2-A(NEMU) and the front panel of ESA12 or the back panel ofESA24 plug-in units, and, if necessary, tie the cable(s) to thecable-shelf
58 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Table 21. LAN cables to remove when MCPC2-A is in use
Equip.No
CABLE FROM CABLE TO Type Use
FU Position/Conn. FU Position/Conn.
RNC:
CA_132 ESA 12 1.0F 12.ETH 5 NEMU/MCPC2-A
1.0F 13 ETH 1 CNI006 LAN(RNC)
ESA 24 1.0B 12.4G NEMU/MCPC2-A
1.0F 13 ETH 1 CHUX048 LAN 1)(RNC)
MGW:
CA_132 ESA 12 1.0F 12.ETH 5 NEMU/MCPC2-A
1.0F 13 ETH 1 CNI006 LAN(MGW)
ESA 24 0 1.0B 12.4G NEMU/MCPC2-A
1.0F 13 ETH 1 CHUS048 LAN 1)(MGW)
CA_133 ESA 24 1 3.0B 13.4G NEMU/MCPC2-A
1.0F 13 ETH 2 CHUS040 LAN 1)(MGW)
1) Cabling from the bottom, tie the cable(s) to the cable shelf
4. Remove serial interface cables CA_306 and CA_307 (MGW only)
Table 22. Serial interface cables to remove when MCPC2-A is in use (MGWonly)
Equip.No
CABLE FROM CABLE TO Type Use
FU Position/Conn. FU Position/Conn.
CA_306 NEMU 1.0B 13U CM 0 1.0F 6.SER1 CHUR045 Serialinterface
CA_307 NEMU 1.0B 13.1Y OMU 0 1.0F 16.SER1 CHUR044 Serialinterface
5. Remove the MCPC2-A (NEMU) plug-in unit from the subrack
a. Unscrew locking screws on the front panel of the plug-in unit.
Locking screws keep the plug-in unit in its place. The numberof locking screws depends on the type of the plug-in unit. SeeFigure Unscrewing locking screws in Replacing plug-in unitwith newer variant.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 59 (179)
Replacing MCPC2-A plug-in unit with MCP18(-B)
b. Open the two insertion/extraction levers on the front panel ofthe plug-in unit.
Insertion/extraction levers are locking clamps which securethe plug-in unit to the rack. Insertion/extraction levers arelocated on the upper and lower edge of the plug-in unit. SeeFigure Opening locking clamps and removing plug-in unit inReplacing plug-in unit with newer variant.
c. Double click (within two seconds) the reset switch in the frontpanel of MCPC2-A.
The electricity switches off. There is no light in the LED lightwhich is in the front panel of the plug-in unit.
The electricity will be off for 20 seconds.
d. Remove the plug-in unit from the subrack.
The MCPC2-A plug-in unit must be removed from the subrackwithin 20 seconds, or it will automatically restart itself.
6. Update the SCSI cabling from hard disk 0 - hard disk 1 to NEMU– hard disk 1
Remove the hard disk 0 ends of the cables CA_093, CA_094 andCA_095 between hard disk 0 and hard disk 1 and install them toNEMU.
Table 23. Removed WDU 0 ends of the CA_093, CA_094 and CA_095 cables
Equip.No
CABLE FROM
FU Position/Conn.
CA_093 hard disk 0(NEMU)
1.0B 14.3Y
CA_094 hard disk 0(NEMU)
1.0B 14.4E
CA_095 hard disk 0(NEMU)
1.0B 14.4P
Table 24. Updated SCSI cabling between NEMU and WDU 1 when MCP18(-B) is in use
Equip.No
CABLE FROM CABLE TO Type Use
FU Position/Conn. FU Position/Conn.
60 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Table 24. Updated SCSI cabling between NEMU and WDU 1 when MCP18(-B) is in use (cont.)
Equip.No
CABLE FROM CABLE TO Type Use
FU Position/Conn. FU Position/Conn.
CA_093 NEMU 1.0B 13.5H hard disk 1(NEMU)
2.0B 14.3F CHS010 SCSI bus1
CA_094 NEMU 1.0B 13.5O hard disk 1(NEMU)
2.0B 14.3M CHS010 SCSI bus1
CA_095 NEMU 1.0B 13.5U hard disk 1(NEMU)
2.0B 14.3S CHS010 SCSI bus1
7. Install the MCP18 or MCP18-B plug-in unit into the subrack
Note
Insert the plug-in unit carefully. It is important to check that the lockingscrews are closed properly, and that the plug-in unit is well in its place.
a. Close the insertion/extraction levers on the front panel of theplug-in units.
Insertion/extraction levers are locking clamps which securethe plug-in units to the rack. Insertion/extraction levers arelocated on the upper and lower edge of the plug-in unit.
b. Close the locking screws carefully.
Locking screws keep the plug-in units in its place. The numberof locking screws depends on the type of the plug-in unit.
8. Insert the LAN cable(s) to the back panel of the MCP18(-B)(NEMU) and the front panel of the ESA12 or the back panel ofthe ESA24 plug-in units
For information on the routing of the cables, see Cable List for RNCand Cable Lists for MGW in site documents.
Table 25. LAN cables to install with MCP18(-B)
Equip.No
CABLE FROM CABLE TO Type Use
FU Position/Conn. FU Position/Conn.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 61 (179)
Replacing MCPC2-A plug-in unit with MCP18(-B)
Table 25. LAN cables to install with MCP18(-B) (cont.)
Equip.No
CABLE FROM CABLE TO Type Use
FU Position/Conn. FU Position/Conn.
RNC:
CA_132 ESA 12 1.0F 12.ETH 5 NEMU/MCP18-B
1.0B 13.3B CHUS048 LAN (RNC)
ESA 24 1.0B 12.4G NEMU/MCP18-B
1.0B 13.3B CHES006 LAN (RNC)
MGW:
CA_132 ESA 12 1.0F 12.ETH 5 NEMU/MCP18
1.0B 13.3B CHUS048 LAN(MGW)
ESA 24 0 1.0B 12.4G NEMU/MCP18
1.0B 13.3B CHES006 LAN(MGW)
CA_133 ESA 24 1 3.0B 13.4G NEMU/MCP18
1.0B 13.3D CHES018 LAN(MGW)
9. Re-install NEMU software
For instructions on installing NEMU software, see the SoftwareDelivery service in NOLS or contact your local Nokia CustomerService Center.
62 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
9 Replacing interface unitsPurpose
This procedure provides instructions for replacing an interface unit with thesame or a newer variant.
This procedure can also be used for replacing the following interface unitswith a different type of an interface unit.
Table 26. Replacing interface units
Procedure Old unit New unit
Replacing NIWU with IWS1E/T(MGW)
IW16P1/A IW1S1
Replacing IWS1E/T with NIWU(MGW)
IW1S1 IW16P1/A
Replacing NIS1/NIS1P withNIP1 (RNC and MGW)
NI4S1-B NI16P1A
Replacing NIP1 with NIS1/NIS1P (RNC and MGW)
NI16P1A NI4S1-B
Note
When using these instructions for replacing an interface unit with thesame or a newer variant, it is not necessary to delete the interfaces,since the same interfaces will be applicable for the new unit.
For more information on plug-in units, see either Nokia MultimediaGateway Plug-in Unit Descriptions or Nokia WCDMA Radio NetworkController Plug-in Unit Descriptions in PDF format in NOLS. For generalinstructions on how to install plug-in units, see Installing plug-in units inInstalling the MGW and RNC.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 63 (179)
Replacing interface units
Insert the plug-in unit carefully. It is important to check that the lockingscrews are closed properly, and that the plug-in unit is well in its place.
Caution
Electrostatic discharge and incorrect installation and uninstallation candamage circuits or shorten their lifetime. To ensure proper functioning ofthe plug-in units during their usual lifetime, take the followingprecautions before handling them:
. Before touching integrated circuits, ensure that you are working in anelectrostatic-free environment.
. Wear an ESD wrist strap or use another corresponding method todischarge static electricity in your body.
For more information on general environmental requirements, seeInstallation Site Requirements for MGW and RNC.
When replacing a 2N redundant unit, you must replace both units. A mixed2N redundant unit configuration with an older and a newer variant of thesame plug-in unit is only allowed as a temporary solution.
Before you start
It is recommended that you maintain a log of spares so that you can traceany plug-in unit at any time.
Before removing or inserting a plug-in unit, all the functional units of theplug-in unit must be in the SE-NH state. For instructions, see Taking unitout of use.
Caution
Traffic related to the interface unit cannot get through during thereplacement of the network element. You should first block the affectedresources before changing the interface unit.
64 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Note
Before replacing an interface unit with a different type of an interfaceunit, all circuits related to the old unit must be deleted.
Steps
1. Change the old unit you want to replace into SE-NH state.
For instructions, see Taking unit out of use
2. If the interface unit is an ATM interface unit (i.e. NI4S1-B orNI16P1A)
Then
Proceed through the following the steps related to ATMinterface units
Note
Make a list of the interfaces of the old unit before deleting them.
a. Delete all ATM interfaces created for the old unit. Forinstructions, see Deleting ATM resources
i. Interrogate the exchange terminals belonging to the oldunit ZUSI:<unit type>,<unit index>::FULL;
ii. Interrogate the affected physical TTP by checking theexchange terminal configuration
ZYAI:PET;
ZYAI:SET;
iii. Interrogate the affected ATM interface by the physicalTTP
ZLAJ:<phyTTP number>;
iv. Delete the affected ATM interface and other resources.For instructions, see Deleting ATM resources.
v. Delete the physical TTP with the command ZYDD;
Else
Continue to step 3
3. Remove the plug-in unit from the subrack
DN70216177Issue 1-0 en
# Nokia Siemens Networks 65 (179)
Replacing interface units
a. Remove the cable(s) from the front panel of the plug-in unit ifthere are any.
Some plug-in units have LAN or STM-1 cable(s) in the frontpanel.
b. Unscrew locking screws on the front panel of the plug-in unit.
Locking screws keep the plug-in unit in its place. The numberof locking screws depends on the type of the plug-in unit.
Figure 8. Unscrewing locking screws
c. Open the two insertion/extraction levers on the front panel ofthe plug-in unit.
Insertion/extraction levers are locking clamps which securethe plug-in unit to the rack. Insertion/extraction levers arelocated on the upper and lower edge of the plug-in unit.
AllenkeyM2.5
DN02220548
66 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Figure 9. Opening locking clamps and removing plug-in unit
d. Remove the plug-in unit from the subrack.
1
1
2
DN70216177Issue 1-0 en
# Nokia Siemens Networks 67 (179)
Replacing interface units
4. Delete the HW description data on the old plug-in unit
Note
When replacing a TDM interface unit (i.e. IW1S1 or IW16P1-A), youneed to keep the same functional unit index number for the ET whenequipping the new unit or, if that is not possible, check the ET used forsignalling by using ZNEL;
Check also the ET used for user plane by using ZRCI; (This commandis used only for MGW.)
Remove the SS7 configuration by following the instrustions inRemoving an MTP singnalling point.
Remove the circuit group, route and digit analysis related to thisinterface unit by following the instructions in Removing circuits fromgroups in MGW.
Follow the instructions in Deleting HW description data whenreplacing plug-in units.
5. Create the HW description data on the new plug-in unit
Follow the instructions in Creating HW description data whenreplacing plug-in units.
6. Install the plug-in unit into the subrack
a. Close the insertion/extraction levers on the front panel of theplug-in unit.
Insertion/extraction levers are locking clamps which securethe plug-in unit to the rack. Insertion/extraction levers arelocated on the upper and lower edge of the plug-in unit.
b. Close the locking screws carefully.
Locking screws keep the plug-in unit in its place. The numberof locking screws depends on the type of the plug-in unit.
c. Insert cable(s) to the front panel of the plug-in unit if there areany.
Some plug-in units have LAN or STM-1 cable(s) in the frontpanel.
7. Check the software version of the HMS node of the interfacecard
68 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
For instructions, see Checking the software version of the HMSnode.
8. Set the functional units into SE-OU working state (USC)
ZUSC:<unit type>,<unit index>:SE;
9. Set the functional units into TE working state (USC)
ZUSC:<unit type>,<unit index>:TE;
Wait until all functional units have restarted.
Expected outcome
All the units in the hierarchy should now be in TE-EX working state.
Unexpected outcome
If the unit restart fails, contact your local Nokia Customer ServiceCenter.
10. Check the version of the flash memory boot package of theplug-in unit against the SW package (WDI)
You can check the boot package versions of all functional units of acertain type by giving the name of the functional unit (for example,NIWU) as the value for the unit type parameter.
ZWDI:UT=<unit type>,UI=<unit index>;
For more information on the boot package compatibility andexamples, see Checking and updating the boot package of acomputer unit in Software Configuration Management.
Expected outcome
If the flash memory boot packages are compatible, you cancontinue.
Unexpected outcome
If the flash memory boot packages are not compatible, you mustupdate the boot package. Follow the instructions in Checking andupdating the boot package of a computer unit in SoftwareConfiguration Management.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 69 (179)
Replacing interface units
11. Check that the repair operation was successful by starting totaldiagnosis of the unit (UDU)
ZUDU:<unit type>,<unit index>;
For more information, see Diagnostics and testing.
12. Set the unit to WO or SP working state (USC)
Depending on the redundancy principle of the unit, set the unitworking state to WO-EX or SP-EX (2N units).
ZUSC:<unit type>,<unit index>:WO|SP;
13. Create all the interfaces and links to the new unit
Note
If the interfaces of the old unit are applicable for the new unit, you canre-create the interfaces according to the list you made of the old unit'sinterfaces.
This step depends on the network planning. For instructions, seeIntergrate in RNC or MGW Product Documentation.
14. Check that there are no on-state alarms for the functional unit(AAP)
ZAAP;
15. Document update
Record unit type changes in corresponding site documents.
70 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
10 MCPC2(-A) plug-in unit is faultyDescription
When an MCPC2 or MCPC2-A (NEMU) plug-in unit is faulty, you mustreplace the faulty unit.
For more information on plug-in units, see either Nokia MultimediaGateway Plug-in Unit Descriptions or Nokia WCDMA Radio NetworkController Plug-in Unit Descriptions in PDF format in NOLS. For generalinstructions on how to install plug-in units, see Installing plug-in units in thesite document Installing the MGW and RNC.
Symptoms
If an MCPC2 or MCPC2-A plug-in unit is faulty, NEMU displays bluescreen during boot, or is in restart loop, or is otherwise non-functional.
Recoveryprocedures
Replacing MCPC2(-A) plug-in unit with the same variant
Purpose
Note that the equipment database does not recognise MCPC2 or MCPC2-A, and it does not have working states.
If you want to replace the plug-in unit with a newer variant, see ReplacingMCPC2 plug-in unit with MCP18(-B) or Replacing MCPC2-A plug-in unitwith MCP18(-B).
DN70216177Issue 1-0 en
# Nokia Siemens Networks 71 (179)
MCPC2(-A) plug-in unit is faulty
Caution
Electrostatic discharge and incorrect installation and uninstallation candamage circuits or shorten their lifetime. To ensure proper functioning ofthe plug-in units during their usual lifetime, take the followingprecautions before handling them.
. Before touching integrated circuits, ensure that you are working in anelectrostatic-free environment.
. Wear an ESD wrist strap or use another corresponding method todischarge static electricity in your body.
For more information on general environmental requirements, seeInstallation Site Requirements for Nokia IPA2800 Network Elements.
Note
Insert the plug-in unit carefully. It is important to check that the lockingscrews are closed properly, and that the plug-in unit is well in its place.
When replacing an MCPC2 and MCPC2-A plug-in unit, it is recommendedto perform NEMU shutdown using the Platform Manager UI tool (steps 1–4), if it is possible. For more detailed instructions, see NEMU PlatformManager User Interface.
Before you start
Always check the interchangeability of the spare plug-in unit beforechanging the unit. The interchangeability sticker is located in the frontpanel of the plug-in unit after the C number. The interchangeability code ofthe new plug-in unit must be the same as or newer than the old plug-inunit's code. If the interchangeability code of the new plug-in unit is newerthan the old unit's code, check the effects on the interchangeability of thesubrack and the other plug-in units.
It is recommended that you maintain a log of spares so that you can traceany plug-in unit at any time.
Steps
1. Log on to NEMU using Nemuadmin account (if possible)
72 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
If NEMU displays blue screen during boot, or is in restart loop, or isotherwise non-functional, please continue from step 5.
2. Start Platform Manager User Interface
Click Start > Programs > Nemu Platform Manager User Interface> PMUI.
3. Shut down the Platform Manager
Click the Stop PM button, or select Stop Platform Manager in thePlatform menu. The confirmation dialog opens. Click OK to confirmthis operation. Wait until the status is Platform Manager not running.
4. Shut down NEMU by selecting Shut down from the Start menu
When the Shut Down Windows message appears, select Shut downand confirm this by clicking OK in the dialog box.
5. Wait until the message appears that it is now safe to turn offyour computer
6. Remove the plug-in unit from the subrack
a. Remove the cables located on the front panel of the plug-inunit.
b. Unscrew the locking screws on the front panel of the plug-inunit.
Locking screws keep the plug-in unit in its place. Lockingscrews are located on top of the insertion/extraction levers.See Figure Unscrewing locking screws in Replacing plug-inunit with the same variant.
c. Open insertion/extraction levers on the front panel of the plug-in unit.
Insertion/extraction levers are locking clamps which securethe plug-in unit to the rack. Insertion/extraction levers arelocated on the upper and lower edge of the plug-in unit. SeeFigure Opening locking clamps and removing plug-in unit inReplacing plug-in unit with the same variant.
d. Double click (within two seconds) the reset switch in the frontpanel of MCPC2(-A).
The electricity switches off. There is no light in the LED lightwhich is in the front panel of the plug-in unit.
The electricity will be off for 20 seconds.
e. Remove the plug-in unit from the subrack within 20 seconds.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 73 (179)
MCPC2(-A) plug-in unit is faulty
If you do not remove the unit within 20 seconds, the unit willautomatically restart itself.
7. Check that the marking strip is correct
Insert the correct marking strip if you have received a new markingstrip, or if there is no marking strip inside the subrack where the plug-in unit was located.
8. Install the new plug-in unit in the subrack
a. Insert the spare plug-in unit in its location.
b. Close the insertion/extraction levers on the front panel of theplug-in unit.
c. Close the locking screws carefully.
d. Insert cables back to the front panel of the plug-in unit.
9. Log on to NEMU using Nemuadmin account
10. Start Platform Manager User Interface
Click Start > Programs > Nemu Platform Manager User Interface> PMUI.
11. Check that the Platform Manager is running
If it is not on, click the Start PM button or select Start PlatformManager from the Platform menu. The Platform Manager starts.
If it is on, the Start PM button and Start Platform Manager in thePlatform menu are inactive and the Status field has the text Nemusoftware running.
12. Check Windows Event Log for any error messages
Select Start > Programs > Administrative Tools > Event Viewerand then select Start Event Viewer. Check that there are noabnormal events since the last restart.
74 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
11 MCP18(-B) plug-in unit is faultyDescription
When an MCP18 or MCP18-B plug-in unit is faulty, you must replace thefaulty unit.
For more information on plug-in units, see either Nokia MultimediaGateway Plug-in Unit Descriptions or Nokia WCDMA Radio NetworkController Plug-in Unit Descriptions in PDF format in NOLS. For generalinstructions on how to install plug-in units, see Installing plug-in units in thesite document Installing the MGW and RNC.
Symptoms
If an MCP18 or MCP18-B plug-in unit is faulty, NEMU displays a bluescreen during boot, or is in restart loop, or is otherwise non-functional.
Recoveryprocedures
Replacing MCP18(-B) plug-in unit with the same variant
Purpose
An MCP18 and MCP18-B plug-in unit uses the Windows 2000 operatingsystem. Note that the equipment database does not recognise MCP18 orMCP18-B, and it does not have working states.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 75 (179)
MCP18(-B) plug-in unit is faulty
Caution
Electrostatic discharge and incorrect installation and uninstallation candamage circuits or shorten their lifetime. To ensure proper functioning ofthe plug-in units during their usual lifetime, take the followingprecautions before handling them.
. Before touching integrated circuits, ensure that you are working in anelectrostatic-free environment.
. Wear an ESD wrist strap or use another corresponding method todischarge static electricity in your body.
For more information on general environmental requirements, seeInstallation Site Requirements for MGW and RNC.
Note
Insert the plug-in unit carefully. It is important to check that the lockingscrews are closed properly, and that the plug-in unit is well in its place.
When replacing an MCP18 and MCP18-B plug-in unit, it is recommendedto perform NEMU shutdown using the Platform Manager UI tool (steps 1–4), if this is possible. For more detailed instructions, see NEMU PlatformManager User Interface.
Before you start
Always check the interchangeability of the spare plug-in unit beforechanging the unit. The interchangeability sticker is located in the frontpanel of the plug-in unit after the C number. The interchangeability code ofthe new plug-in unit must be the same as or newer than the old plug-inunit's code. If the interchangeability code of the new plug-in unit is newerthan the old unit's code, check the effects on the interchangeability of thesubrack and the other plug-in units.
It is recommended that you maintain a log of spares so that you can traceany plug-in unit at any time.
Steps
1. Log on to NEMU using Nemuadmin account (if possible)
76 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
If NEMU displays a blue screen during boot, or is in restart loop, or isotherwise non-functional, please continue from step 5.
2. Start Platform Manager User Interface
Click Start > Programs > Nemu Platform Manager User Interface> PMUI
3. Shut down NEMU by selecting Shut down from the Start menu
When the Shut Down Windows message appears, select Shut downand confirm this by clicking OK in the dialog box.
4. Wait until the message appears that it is now safe to turn offyour computer
5. Remove the plug-in unit from the subrack
a. Remove the cables located on the front panel of the plug-inunit.
b. Unscrew the locking screws on the front panel of the plug-inunit.
Locking screws keep the plug-in unit in its place. Lockingscrews are located on top of the insertion/extraction levers.See Figure Unscrewing locking screws in Replacing plug-inunit with the same variant.
c. Open insertion/extraction levers on the front panel of the plug-in unit.
Insertion/extraction levers are locking clamps which securethe plug-in unit to the rack. Insertion/extraction levers arelocated on the upper and lower edge of the plug-in unit. SeeFigure Opening locking clamps and removing plug-in unit inReplacing plug-in unit with the same variant.
d. Remove the plug-in unit from the subrack.
6. Install the new plug-in unit in the subrack
a. Insert the spare plug-in unit in its location.
b. Close the insertion/extraction levers on the front panel of theplug-in unit.
c. Close the locking screws carefully.
d. Insert cables back to the front panel of the plug-in unit.
7. Log on to NEMU using Nemuadmin account and start PlatformManager User Interface
DN70216177Issue 1-0 en
# Nokia Siemens Networks 77 (179)
MCP18(-B) plug-in unit is faulty
Click Start > Programs > Nemu Platform Manager User Interface> PMUI
8. Check that the Platform Manager is running
If it is running, the Start PM button and Start Platform Manager inthe Platform menu are inactive and Status field has text Nemusoftware running....
9. If the Platform Manager is not running
Then
Click the Start PM button or select Start Platform Manager inPlatform menu
The Platform Manager starts.
10. Check Windows Event Log for any error messages
Start Event Viewer from Start > Programs > Administrative Tools> Event Viewer. Check that there are no abnormal events since thelast restart.
78 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
12 PD20 plug-in unit is faultyDescription
When a PD20 plug-in unit (subrack power supply) is faulty, you mustreplace the faulty unit.
For more information on plug-in units, see either Nokia WCDMA RadioNetwork Controller Plug-in Unit Descriptions or Nokia Multimedia GatewayPlug-in Unit Descriptions in PDF format in NOLS. For general instructionson how to install plug-in units, see Installing plug-in units in Installing theMGW and RNC.
For instructions on how to replace a faulty fuse in PD20 plug-in unit, seeFuse in PD20 plug-in unit is faulty.
Symptoms
One or several alarms number 3000 are set when a PD20 plug-in unit isfaulty.
Recoveryprocedures
Replacing PD20 plug-in unit with the same variant
Purpose
The PD20 plug-in unit is a subrack power supply. A PD20 plug-in unit doesnot have working states.
Note that changing a PD20 plug-in unit might affect the grade of service.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 79 (179)
PD20 plug-in unit is faulty
Caution
Electrostatic discharge and incorrect installation and uninstallation candamage circuits or shorten their lifetime. To ensure proper functioning ofthe plug-in units during their usual lifetime, take the followingprecautions before handling them.
. Before touching integrated circuits, ensure that you are working in anelectrostatic-free environment.
. Wear an ESD wrist strap or use another corresponding method todischarge static electricity in your body.
For more information on general environmental requirements, seeInstallation Site Requirements for MGW and RNC.
Note
Insert the plug-in unit carefully. It is important to check that the lockingscrews are closed properly, and that the plug-in unit is well in its place.
Before you start
Always check the interchangeability of the spare plug-in unit from theRevision List before changing the unit. If you are not sure about theinterchangeability of the plug-in unit variants, please refer to the latestRNC or MGW HW Revision List available in NOLS.
The interchangeability sticker is located in the front panel of the plug-in unitafter the C number. The interchangeability code of the new plug-in unitmust be the same as or newer than the old plug-in unit's code. If theinterchangeability code of the new plug-in unit is newer than the old unit'scode, check the effects on the interchangeability of the subrack and theother plug-in units.
It is recommended that you maintain a log of spares so that you can traceany plug-in unit at any time.
Before removing or inserting the PD20 plug-in unit, all the functional unitsof the units in the subrack must be in the SE-NH state.
80 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
1. Check if any of the functional units is an N+1 redundant unit (ISU orICSU) and if its working state is other than WO-EX or WO-RE. WithN+1 redundant units, one unit is usually in SP-EX state.
2. If there is a functional unit of this kind, use the USI command todisplay its logical address.
ZUSI;
3. Write down the logical address.
4. Change the working state of all the functional units in the subrack toSE-NH. For instructions, see Taking unit out of use.
When changing the PD20 plug-in unit in the first subrack, whereTSS3 0 is located, TBU 0 must be in SE-NH state. When changingthe PD20 plug in unit in the second subrack, where TSS3 1 islocated, TBU 1 must be in SE-NH state.
When changing the PD20 plug-in unit, you must first block the alarm 3000(PLUG-IN UNIT POWER FAILURE). After changing the PD20 plug-in unit,you must unblock the alarm.
1. Block the alarm 3000.
AFB:3000::RES::;
2. Change the PD20 plug-in unit as described in the steps 1-11.
3. After changing the PD20 plug-in unit, unblock the alarm 3000.
ZAFU:3000::;.
Before changing the PD20 plug-in unit, you must block the alarm 1291(SUBRACK CONNECTIVITY FAILURE). After changing the PD20 plug-inunit, you must unblock the alarm.
1. Block the alarm 1291.
ZAFB:1291::TOT;
2. Change the PD20 plug-in unit as described in the steps 1-11.
3. After changing the PD20 plug-in unit, unblock the alarm 1291.
ZAFU:1291;
Switching the power off in the first subrack of the first cabinet may cause asevere corruption of the NEMU software, if the NEMU operating systemhas not been shut down in a controlled way before the power is switchedoff. To shut down NEMU:
DN70216177Issue 1-0 en
# Nokia Siemens Networks 81 (179)
PD20 plug-in unit is faulty
1. Log on to NEMU using Nemuadmin account.
2. Shut down the NEMU by selecting Shut down from the Start menu.When the Shut Down Windows message appears, select Shut downand confirm this by clicking OK in the dialog box.
3. Wait until the message appears that it is now safe to turn off yourcomputer.
4. When the operating system is shut down, immediately disconnectthe MCPC2, MCPC2-A, MCP18 or MCP18-B plug-in unit from thesubrack.
Before you switch the power back on to the first subrack of the first cabinet,reconnect the MCPC2, MCPC2-A, MCP18 or MCP18-B plug-in unit to thesubrack.
Steps
1. Turn off the power from the subrack that belongs to the supplybranch with the faulty PD20
Turn off the subrack power only from the CPD80-B power unit(located in the upper part of the cabinet) that belongs to the supplybranch with the faulty PD20.
The units in the subrack must be in SE-NH state before you turn offthe switches.
When you turn the first switch off, there will be two alarms (3118 and3134). The alarms disappear when you turn the second switch off.
2. Remove the plug-in unit from the subrack
a. Unscrew the locking screws on the front panel of the plug-inunit.
Locking screws keep the plug-in unit in its place. Lockingscrews are located on top of the insertion/extraction levers.See Figure Unscrewing locking screws in Replacing plug-inunit with the same variant.
b. Open insertion/extraction levers on the front panel of the plug-in unit.
Insertion/extraction levers are locking clamps which securethe plug-in unit to the rack. Insertion/extraction levers arelocated on the upper and lower edge of the plug-in unit. SeeFigure Opening locking clamps and removing plug-in unit inReplacing plug-in unit with the same variant.
c. Remove the plug-in unit from the subrack.
82 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
3. Install the new plug-in unit in the subrack
a. Insert the spare plug-in unit in its location.
b. Close the insertion/extraction levers on the front panel of theplug-in unit.
c. Close the locking screws carefully.
4. Turn on the power to one of the switches that you turned off
Either the alarm 3118 or 3134 is set.
5. Turn on the power to the other switch that you turned off
6. Check the compatibility of the HMS node SW version of theplug-in unit
The HMS node SW version can only be checked with a serviceterminal command. The HMS node SW version information consistsof version, edition and repair number (X.Y-Z). HMS release level isdefined by X.Y. Nodes which have the same release level arecompatible. All HMS nodes within one network element must havethe same release level within the HMS hierarchy. For instance, allthe slave nodes must have the same release level which can,however, be different from the release level of the brigde nodes. Formore information on HMS node and HMS addressing, see Hardwareconfiguration data management in Hardware ConfigurationManagement for MGW or RNC.
a. Open a remote debugger session to the active OMU.
ZDDS:OMU,<index of the active unit>;
b. Load the HME service terminal extension.
0x-MAN>ZLP:1,HME
c. Display the HMS node SW version.
0x-MAN>Z1CO:<rack>,<subrack>,<ppa>
d. Check that the SW version is compatible.
e. Remove the HME service terminal extension.
0x-HME>ZL:1
f. Close the remote debugger session.
0x-MAN>ZE
If the HMS node SW version is incompatible, remove the plug-in unitand contact your local Nokia Customer Service Center.
7. Check data on the plug-in unit (WFL)
DN70216177Issue 1-0 en
# Nokia Siemens Networks 83 (179)
PD20 plug-in unit is faulty
ZWFL:P:<cabinet hms number>,<subrack hms number>,<ppa>;
Verify that plug-in unit data is correct.
8. Change the units back to normal working state (USC)
Change all the functional units back to normal working state.Depending on the redundancy principle of the unit, the normalworking state is WO-EX or SP-EX.
Note
If there was a spare N+1 redundant unit in the subrack, change it backto SP-EX state. You should have the logical address of the unit writtendown.
ZUSC:<unit type>,<unit index>:SP|WO;
9. Check that all functional units in the subrack are in normalworking state (WO or SP) (USI)
ZUSI:<unit type>;
10. If there are still functional units that are not in WO or SP state
Then
Change the unit to the SP or WO working state (USC)
ZUSC:<unit type>,<unit index>:SP|WO;
84 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
13 Fuse in PD20 plug-in unit is faultyDescription
When a fuse in a PD20 plug-in unit (subrack power supply) is faulty, youmust replace the faulty fuse.
For more information on the PD20 plug-in units and its fuses, see eitherNokia Multimedia Gateway Plug-in Unit Descriptions or Nokia WCDMARadio Network Controller Plug-in Unit Descriptions in PDF format inNOLS.
For instruction on how to replace a PD20 plug-in unit, see PD20 plug-inunit is faulty.
Symptoms
One or several alarms number 3000 are set when a fuse in PD20 plug-inunit is faulty.
Recoveryprocedures
Replacing a fuse in PD20 plug-in unit
Steps
1. Locate the faulty fuse
A red LED in the front panel of the PD20 indicates which fuse isfaulty.
2. Turn off the power from the subrack that belongs to the supplybranch with the faulty fuse
DN70216177Issue 1-0 en
# Nokia Siemens Networks 85 (179)
Fuse in PD20 plug-in unit is faulty
Turn off the subrack power only from the CPD80-B power unit(located in the upper part of the cabinet) that belongs to the supplybranch with the faulty fuse. From top to bottom, the first five fusesform one group for supplying the first branch (UB1) and the next fivefuses another group for supplying the second supply branch (UB2).
When you turn the switch off, the red LED indicating the fuse failuregoes out and the LED that indicates lack of supply voltage in thesupply branch in question is lit.
3. Remove the faulty fuse
a. Unscrew the cap of the fuse holder.
b. Remove the fuse.
4. Insert new fuse
a. Insert a new fuse.
b. Screw the cap back into the fuse holder.
5. Turn on the power switch
86 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
14 PD30 plug-in unit is faultyDescription
When a PD30 plug-in unit (subrack power supply) is faulty, you mustreplace the faulty unit.
For more information on plug-in units, see either Nokia WCDMA RadioNetwork Controller Plug-in Unit Descriptions or Nokia Multimedia GatewayPlug-in Unit Descriptions in PDF format in NOLS. For general instructionson how to install plug-in units, see Installing plug-in units in Installing theMGW and RNC.
For instructions on how to replace a faulty fuse in PD30 plug-in unit, seeFuse in PD30 plug-in unit is faulty.
Symptoms
One or several alarms number 3000 are set when a PD30 plug-in unit isfaulty.
Recoveryprocedures
Replacing PD30 plug-in unit with the same variant
Purpose
The PD30 plug-in unit is a subrack power supply. A PD30 plug-in unit doesnot have working states.
Note that changing a PD30 plug-in unit might affect the grade of service.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 87 (179)
PD30 plug-in unit is faulty
Caution
Electrostatic discharge and incorrect installation and uninstallation candamage circuits or shorten their lifetime. To ensure proper functioning ofthe plug-in units during their usual lifetime, take the followingprecautions before handling them.
. Before touching integrated circuits, ensure that you are working in anelectrostatic-free environment.
. Wear an ESD wrist strap or use another corresponding method todischarge static electricity in your body.
For more information on general environmental requirements, seeInstallation Site Requirements for MGW and RNC.
Note
Insert the plug-in unit carefully. It is important to check that the lockingscrews are closed properly, and that the plug-in unit is well in its place.
Before you start
Always check the interchangeability of the spare plug-in unit from theRevision List before changing the unit. If you are not sure about theinterchangeability of the plug-in unit variants, please refer to the latestRNC or MGW HW Revision List available in NOLS.
The interchangeability sticker is located in the front panel of the plug-in unitafter the C number. The interchangeability code of the new plug-in unitmust be the same as or newer than the old plug-in unit's code. If theinterchangeability code of the new plug-in unit is newer than the old unit'scode, check the effects on the interchangeability of the subrack and theother plug-in units.
It is recommended that you maintain a log of spares so that you can traceany plug-in unit at any time.
Before removing or inserting the PD30 plug-in unit, all the functional unitsof the units in the subrack must be in the SE-NH state.
88 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
1. Check if any of the functional units is an N+1 redundant unit (ISU orICSU) and if its working state is other than WO-EX or WO-RE. WithN+1 redundant units, one unit is usually in SP-EX state.
2. If there is a functional unit of this kind, use the USI command todisplay its logical address.
ZUSI;
3. Write down the logical address.
4. Change the working state of all the functional units in the subrack toSE-NH. For instructions, see Taking unit out of use.
When changing the PD30 plug in unit in the first subrack, whereTSS3 0 is located, TBU 0 must be in SE-NH state. When changingthe PD30 plug in unit in the second subrack, where TSS3 1 islocated, TBU 1 must be in SE-NH state.
Switching the power off in the first subrack of the first cabinet may cause asevere corruption of the NEMU software, if the NEMU operating systemhas not been shut down in a controlled way before the power is switchedoff. To shut down NEMU:
1. Log on to NEMU using Nemuadmin account.
2. Shut down the NEMU by selecting Shut down from the Start menu.When the Shut Down Windows message appears, select Shut downand confirm this by clicking OK in the dialog box.
3. Wait until the message appears that it is now safe to turn off yourcomputer.
4. When the operating system is shut down, immediately disconnectthe NEMU plug-in unit from the subrack.
Before you switch the power back on to the first subrack of the first cabinet,reconnect the NEMU plug-in unit to the subrack.
Steps
1. Block the alarm 1291 (SUBRACK CONNECTIVITY FAILURE)
ZAFB:1291::TOT;
2. Turn off the power from the subrack that belongs to the supplybranch with the faulty PD30
DN70216177Issue 1-0 en
# Nokia Siemens Networks 89 (179)
PD30 plug-in unit is faulty
Turn off the subrack power only from the CPD80-B/CPD120/CPD120-A power unit (located in the upper part of the cabinet) thatbelongs to the supply branch with the faulty PD30.
The units in the subrack must be in SE-NH state before you turn offboth the switches.
When you turn the first switch off, there will be two alarms (3118 and3134). The alarms disappear when you turn the second switch off.
3. Remove the plug-in unit from the subrack
a. Unscrew the locking screws on the front panel of the plug-inunit.
Locking screws keep the plug-in unit in its place. Lockingscrews are located on top of the insertion/extraction levers.See Figure Unscrewing locking screws in Replacing plug-inunit with the same variant.
b. Open insertion/extraction levers on the front panel of the plug-in unit.
Insertion/extraction levers are locking clamps which securethe plug-in unit to the rack. Insertion/extraction levers arelocated on the upper and lower edge of the plug-in unit. SeeFigure Opening locking clamps and removing plug-in unit inReplacing plug-in unit with the same variant.
c. Remove the plug-in unit from the subrack.
4. Install the new plug-in unit in the subrack
a. Insert the spare plug-in unit in its location.
b. Close the insertion/extraction levers on the front panel of theplug-in unit.
c. Close the locking screws carefully.
5. Turn on the power to one of the switches that you turned off
Either the alarm 3118 or 3134 is set.
6. Turn on the power to the other switch that you turned off
7. Check the compatibility of the HMS node SW version of theplug-in unit
The HMS node SW version can only be checked with a serviceterminal command. The HMS node SW version information consistsof version, edition and repair number (X.Y-Z). HMS release level isdefined by X.Y. Nodes which have the same release level are
90 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
compatible. All HMS nodes within one network element must havethe same release level within the HMS hierarchy. For instance, allthe slave nodes must have the same release level which can,however, be different from the release level of the brigde nodes. Formore information on HMS node and HMS addressing, see Hardwareconfiguration data management in Hardware ConfigurationManagement for MGW or RNC.
a. Open a remote debugger session to the active OMU.
ZDDS:OMU,<index of the active unit>;
b. Load the HME service terminal extension.
0x-MAN>ZLP:1,HME
c. Display the HMS node SW version.
0x-MAN>Z1CO:<rack>,<subrack>,<ppa>
d. Check that the SW version is compatible.
e. Remove the HME service terminal extension.
0x-HME>ZL:1
f. Close the remote debugger session.
0x-MAN>ZE
If the HMS node SW version is incompatible, remove the plug-in unitand contact your local Nokia Customer Service Center.
8. Check data on the plug-in unit (WFL)
ZWFL:P:<cabinet hms number>,<subrack hms number>,<ppa>;
Verify that plug-in unit data is correct.
9. Change the units back to normal working state (USC)
Change all the functional units back to normal working state.Depending on the redundancy principle of the unit, the normalworking state is WO-EX or SP-EX.
Note
If there was a spare N+1 redundant unit in the subrack, change it backto SP-EX state. You should have the logical address of the unit writtendown.
ZUSC:<unit type>,<unit index>:SP|WO;
DN70216177Issue 1-0 en
# Nokia Siemens Networks 91 (179)
PD30 plug-in unit is faulty
10. Check that all functional units in the subrack are in normalworking state (WO or SP) (USI)
ZUSI:<unit type>;
11. If there are still functional units that are not in WO or SP state
Then
Change the unit to the SP or WO working state (USC)
ZUSC:<unit type>,<unit index>:SP|WO;
12. Unblock the alarm 1291 (SUBRACK CONNECTIVITY FAILURE).
ZAFU:1291;
92 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
15 Fuse in PD30 plug-in unit is faultyDescription
When a fuse in a PD30 plug-in unit (subrack power supply) is faulty, youmust replace the faulty fuse. The fuses used with PD30 plug-in unit are10A 250V fast fuse (FA1...FA4, FB1...FB4) and 6.3A 250V slow fuse (FA5,FB5).
For more information on the PD30 plug-in unit and its fuses, see eitherNokia Multimedia Gateway Plug-in Unit Descriptions or Nokia WCDMARadio Network Controller Plug-in Unit Descriptions in PDF format inNOLS.
For instruction on how to replace a PD30 plug-in unit, see PD30 plug-inunit is faulty.
Symptoms
One or several alarms number 3000 are set when a fuse in PD30 plug-inunit is faulty.
Recoveryprocedures
Replacing a fuse in PD30 plug-in unit
Steps
1. Locate the faulty fuse
A red LED in the front panel of the PD30 indicates which fuse isfaulty.
2. Turn off the power from the subrack that belongs to the supplybranch with the faulty fuse
DN70216177Issue 1-0 en
# Nokia Siemens Networks 93 (179)
Fuse in PD30 plug-in unit is faulty
Turn off the subrack power only from the CPD80-B/CPD120/CPD120-A power unit (located in the upper part of the cabinet) thatbelongs to the supply branch with the faulty fuse. From top tobottom, the first five fuses form one group for supplying the firstbranch (UB1) and the next five fuses another group for supplying thesecond supply branch (UB2).
When you turn the switch off, the red LED indicating the fuse failuregoes out and the LED that indicates lack of supply voltage in thesupply branch in question is lit.
3. Remove the faulty fuse
a. Unscrew the cap of the fuse holder.
b. Remove the fuse.
4. Insert new fuse
a. Insert a new fuse.
b. Screw the cap back into the fuse holder.
5. Turn on the power switch
94 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
16 ESA12 plug-in unit is faultyDescription
When an ESA12 plug-in unit is faulty, you must replace the faulty unit.
Depending on the network element, see either Nokia WCDMA RadioNetwork Controller Plug-in Unit Descriptions or Nokia Multimedia GatewayPlug-in Unit Descriptions in PDF format in NOLS for more information onplug-in units. For general instructions on how to install plug-in units, seeInstalling plug-in units in Installing the MGW and RNC.
Symptoms
A red LED in the front panel of the ESA12 plug-in unit indicates that theplug-in unit has a fatal hardware failure.
Recoveryprocedures
Replacing ESA12 plug-in unit with the same variant
Purpose
Note that the equipment database does not recognise ESA12, and it doesnot have working states.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 95 (179)
ESA12 plug-in unit is faulty
Caution
Electrostatic discharge and incorrect installation and uninstallation candamage circuits or shorten their lifetime. To ensure proper functioning ofthe plug-in units during their usual lifetime, take the followingprecautions before handling them.
. Before touching integrated circuits, ensure that you are working in anelectrostatic-free environment.
. Wear an ESD wrist strap or use another corresponding method todischarge static electricity in your body.
For more information on general environmental requirements, seeInstallation Site Requirements fo MGW and RNC.
Note
Insert the plug-in unit carefully. It is important to check that the lockingscrews are closed properly, and that the plug-in unit is well in its place.
Before you start
Always check the interchangeability of the spare plug-in unit beforechanging the unit. The interchangeability sticker is located in the frontpanel of the plug-in unit after the C number. The interchangeability code ofthe new plug-in unit must be the same as or newer than the old plug-inunit's code. If the interchangeability code of the new plug-in unit is newerthan the old unit's code, check the effects on the interchangeability of thesubrack and the other plug-in units.
It is recommended that you maintain a log of spares so that you can traceany plug-in unit at any time.
The following is assumed in taking the backup of the configurationfile in this instruction:
. The IP address of the upgraded switch is 192.168.0.5.
. The IP address of the PC that is used as a TFTP client is in the samesubnetwork as the IP address of the ESA12.
96 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
If the IP address of the PC is not in the same subnetwork as the IPaddress of the ESA12, the TFTP transfer can only be done properlyif there is a router between the subnetworks directing the IP packetsto the correct subnetwork.
Check that you have the following:
. the ESA12 unit that needs to be upgraded
. a PC or a laptop with an Ethernet card installed in it
. TFTP client application installed on a PC or a laptop
The Windows 2000 and Linux operating systems include a TFTPclient application. If you have another operating system, you mustinstall the TFTP application separately on the PC or laptop. You canpurchase an commercial TFTP client application or download afreeware TFTP client application from the Internet.
. Telnet or service terminal program installed on a PC or a laptop
If you are updating the ESA12 software using only the Ethernetconnection, you need a Telnet program.
If you are updating ESA12 software using service terminal sessionand the Ethernet connection, you need a service terminal program.
. one straight-through Ethernet cable (RJ-45)
If the network element has only one ESA12 plug-in unit, you need to blockthe alarm 3053 (ETHERNET INTERFACE FAILURE) before replacing thenetwork element and unblock it after you have replaced the networkelement.
1. Block the alarm 3053.
AFB:3053::RES::;
2. Change the plug-in unit as described in the steps 1-13.
3. After changing the plug-in unit, unblock the alarm 3053.
ZAFU:3053::;.
Steps
1. Take a backup of the configuration file of the ESA12 switch
a. Connect the PC or laptop to one of the Ethernet ports of theESA12 switch with an Ethernet cable
b. Check that the Ethernet switch is powered up.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 97 (179)
ESA12 plug-in unit is faulty
When the ESA12 Ethernet switch is powered up, the LED onthe front panel of the switch is green.
c. If you are using service terminal session and Ethernetconnection
then
Connect the service terminal to ESA12 and start theterminal session:
i. Connect the service terminal to ESA12 with a serialcable.
ii. Start the service terminal session with the followingsettings:. Bitrate: 9600 bit/s. Parity: None. Data bits: 8. Stop bits: 1. Flow control: Xon/Xoff
d. If you are using only the Ethernet connection
then
Connect to the IP address of ESA12 via Telnet
i. Start a Telnet session by selecting Start -> Run on theWindows Taskbar.
ii. Connect to the IP address of ESA12:
telnet <IP address of ESA12>
For example: telnet 192.168.0.5
iii. Press Enter.
e. Log in to ESA12
Enter your login ID and password.
The default password is empty, that is, press Enter to continue.If the password has been changed, enter the new passwordand then press Enter.
NOKIA ESA-12.
Username:nokia
Password:********
The main menu of ESA12 opens:
ESA12 1.28 Aug 17 2000
Main Menu
1. General Configuration
2. SNMP Configuration
3. Ports Configuration
4. Ports Status
98 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
5. Load Factory Defaults
6. Software Upgrade
7. Reset
8. Logout
f. Enable the Upload/Download of the configuration file in theswitch:
i. Press 1 to enter the General Gonfiguration from the Mainmenu.
ii. Press 6 to enter the Advanced Features
iii. Press 7 for Enable Config Upload/Download
iv. Press Y in response to the prompt
g. Use the TFTP program to download and save the filenokia_cfg from the switch to your PC.
2. If the plug-in unit is completely faulty and you are unable to take abackup of the configuration file
Then
Configure ESA12 after you have followed the steps from 3 to 12
3. Remove the LAN cable(s) from the front panel
4. Unscrew the locking screws on the front panel of the plug-inunit
Locking screws keep the plug-in unit in its place. Locking screws arelocated on top of the insertion/extraction levers. See FigureUnscrewing locking screws in Replacing plug-in unit with the samevariant.
5. Open the insertion/extraction levers on the front panel of theplug-in unit
Insertion/extraction levers are locking clamps which secure the plug-in unit to the rack. Insertion/extraction levers are located on theupper and lower edge of the plug-in unit. See Figure Opening lockingclamps and removing plug-in unit in Replacing plug-in unit with thesame variant.
6. Double click (within two seconds) the reset switch in the frontpanel of ESA12
The electricity switches off from the unit. There is no light in the LEDlight which is in the front panel of the plug-in unit.
The electricity will be off for 20 seconds.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 99 (179)
ESA12 plug-in unit is faulty
7. Remove the plug-in unit from the subrack within 20 seconds
If you do not remove the unit within 20 seconds, the unit willautomatically restart itself.
8. Check that the marking strip is correct
Insert the correct marking strip if you have received a new markingstrip, or if there is no marking strip in the subrack where the plug-inunit was located.
9. Insert the spare plug-in unit in its location
10. Close the insertion/extraction levers on the front panel of theplug-in unit
11. Close the locking screws carefully
12. Insert cable(s) back to the front panel of the plug-in unit
13. If you were unable to take a backup of the configuration file (forinstance, because the ESA12 plug-in unit was completely faulty)
Then
Configure ESA12
For instructions, see Configuring ESA12 in IP ConnectionConfiguration for MGW or IP Connection Configuration for RNC.
Else
Follow the instructions below
14. Upload the configuration file to the ESA12 switch
Start the TFTP client program on the PC or laptop and enter therequired settings. Set the following settings in the TFTP program:. Host IP address: IP address of ESA12 (for example,
192.168.0.5). Port: 69. Local file name: the name of the configuration file you copied
to your hard drive. If the TFTP program cannot find the file,change the path settings in the program.
100 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
. Remote file name: the name of the remote configuration filethat will be written to the ESA12 flash memory. The file namefor the configuration file to be loaded into ESA12 shouldalways be 'nokia_cfg'. Note that the file extension is separatedfrom the file name with an underscore (_), not a period.
. Transfer type: Binary
15. Upgrade the ESA12 software
For instructions, see Upgrading ESA12 software in SoftwareConfiguration Management.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 101 (179)
ESA12 plug-in unit is faulty
102 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
17 ESA24 plug-in unit is faultyDescription
When an ESA24 plug-in unit is faulty, you must replace the faulty unit.
Depending on the network element, see either Nokia WCDMA RadioNetwork Controller Plug-in Unit Descriptions or Nokia Multimedia GatewayPlug-in Unit Descriptions in PDF format in NOLS for more information onplug-in units. For general instructions on how to install plug-in units, seeInstalling plug-in units in Installing the MGW and RNC.
Symptoms
A red LED in the front panel of the ESA24 plug-in unit indicates that theplug-in unit has a fatal hardware failure.
Recoveryprocedures
Replacing ESA24 plug-in unit with the same variant
Purpose
Note that the equipment database does not recognise ESA24, and it doesnot have working states.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 103 (179)
ESA24 plug-in unit is faulty
Caution
Electrostatic discharge and incorrect installation and uninstallation candamage circuits or shorten their lifetime. To ensure proper functioning ofthe plug-in units during their usual lifetime, take the followingprecautions before handling them.
. Before touching integrated circuits, ensure that you are working in anelectrostatic-free environment.
. Wear an ESD wrist strap or use another corresponding method todischarge static electricity in your body.
For more information on general environmental requirements, seeInstallation Site Requirements for MGW and RNC.
Note
Insert the plug-in unit carefully. It is important to check that the lockingscrews are closed properly, and that the plug-in unit is well in its place.
Before you start
Note
This procedure will cause disturbances in the H.248 traffic.
Always check the interchangeability of the spare plug-in unit beforechanging the unit. The interchangeability sticker is located in the frontpanel of the plug-in unit after the C number. The interchangeability code ofthe new plug-in unit must be the same as or newer than the old plug-inunit's code. If the interchangeability code of the new plug-in unit is newerthan the old unit's code, check the effects on the interchangeability of thesubrack and the other plug-in units.
It is recommended that you maintain a log of spares so that you can traceany plug-in unit at any time.
The following is assumed in taking the backup of the configurationfile in this instruction:
104 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
. The IP address of the upgraded switch is 192.168.0.5.
. The IP address of the PC that is used as a TFTP server is192.168.0.128.
The IP address of the PC that is used as a TFTP server is selectedfrom the same subnetwork as the IP address of ESA24. If the IPaddress of the PC is not in the same subnetwork as the IP addressof ESA24, the TFTP transfer can only be done properly if there is arouter between the subnetworks directing the IP packets to thecorrect subnetwork.
. The ESA24 unit already has the BiNOS operating system installed.The current version needs to be upgraded to a newer one.
Check that you have the following:
. the ESA24 unit that needs to be upgraded
. PC or a laptop with an Ethernet card installed in it
. TFTP server application installed on a PC or a laptop
Note that the TFTP server application is different from the TFTPclient application.
The Windows 2000 and Linux operating systems include a TFTPserver application. If you have another operating system, you mustinstall the TFTP application separately on the PC or laptop. You canpurchase a commercial TFTP server application or download afreeware TFTP server application from the Internet.
. service terminal program installed on a PC or a laptop
. one straight-through Ethernet cable (RJ-45)
Steps
1. Take a backup of the configuration file of the ESA24 switch
a. Connect the PC or laptop to one of the Ethernet ports of theESA24 switch with an Ethernet cable
b. Check that the Ethernet switch is powered up.
When the ESA24 Ethernet switch is powered up, the LED onthe front panel of the switch is green.
c. Connect to the IP address of ESA24 via Telnet
DN70216177Issue 1-0 en
# Nokia Siemens Networks 105 (179)
ESA24 plug-in unit is faulty
i. Start a Telnet session by selecting Start -> Run on theWindows Taskbar.
ii. Connect to the IP address of ESA24:
telnet <IP address of ESA24>
For example: telnet 192.168.0.5
iii. Press Enter.
d. Log in to ESA24
Enter the default password 'nokia' and press Enter. If thepassword has been changed, enter the new password andthen press Enter.
User Access Verification
Password:
After successful log in, the ESA24 prompt is displayed:
ESA24>
e. Start the TFTP server on the PC or laptop and enter therequired settings.
Set up the TFTP server so that ESA24 is allowed to upload afile to this PC.
There are many different TFTP server applications available.The server management varies between different products, sosee the instructions supplied with the TFTP server application.
f. Enable the privileged mode in BiNOS
Enable the privileged mode in ESA24 operating system withthe command
enable
The privileged mode allows advanced viewing andconfiguration capabilities for the unit.
Note
The command prompt in privileged mode is the number sign, "#".
g. Upload the configuration file of the switch to the TFTP serverto take a backup of the configuration. The TFTP server issupposed to be running on the PC that has the IP address192.168.0.128. The configuration file is copied to TFTP-serverroot directory on PC.
ESB20-A#copy running-config upload-to 192.168.0.128 config.cfg.
Building the configuration ...
Upload complete
106 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
2. If the plug-in unit is completely faulty and you are unable to take abackup of the configuration file
Then
Reconfigure ESA24 manually
You need to reconfigure the ESA24 manually because it is notpossible to upload existing configuration file to TFTP server.Reconfigure ESA24 after you have followed the steps from 3 to 12.
3. Block Alarm 3053 ETHERNET INTERFACE FAILURE
Block the alarm by entering the following MML command:
ZAFB:3053:;
4. Remove the LAN cable(s) from the front panel
5. Unscrew the locking screws on the front panel of the plug-inunit
Locking screws keep the plug-in unit in its place. Locking screws arelocated on top of the insertion/extraction levers. See FigureUnscrewing locking screws in Replacing plug-in unit with the samevariant.
6. Open the insertion/extraction levers on the front panel of theplug-in unit
Insertion/extraction levers are locking clamps which secure the plug-in unit to the rack. Insertion/extraction levers are located on theupper and lower edge of the plug-in unit. See Figure Opening lockingclamps and removing plug-in unit in Replacing plug-in unit with thesame variant.
7. Double click (within two seconds) the reset switch in the frontpanel of ESA24
The electricity switches off from the unit. There is no light in the LEDlight which is in the front panel of the plug-in unit.
The electricity will be off for 20 seconds.
8. Remove the plug-in unit from the subrack within 20 seconds
DN70216177Issue 1-0 en
# Nokia Siemens Networks 107 (179)
ESA24 plug-in unit is faulty
If you do not remove the unit within 20 seconds, the unit willautomatically restart itself.
9. Check that the marking strip is correct
Insert the correct marking strip if you have received a new markingstrip, or if there is no marking strip inside the subrack where the plug-in unit was located.
10. Insert the spare plug-in unit in its location
11. Close the insertion/extraction levers on the front panel of theplug-in unit
12. Close the locking screws carefully
13. If you were unable to take a backup of the configuration file (forinstance, if the plug-in unit is completely faulty)
Then
Reconfigure ESA24
For instructions, see Configuring ESA24 in IP ConnectionConfiguration for MGW or IP Connection Configuration for RNC.
Else
Follow the instructions below
14. Download the configuration file to ESA24
Use the TFTP server to download the configuration file to ESA24.
15. Insert cable(s) back to the front panel of the plug-in unit
16. Remove the alarm blocking of Alarm 3053 ETHERNETINTERFACE FAILURE
Unblock the alarm by entering the following MML command:
ZAFU:3053:;
17. Upgrade the ESA24 software
For instructions, see Upgrading ESA24 software in SoftwareConfiguration Management.
108 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
18 BIE1C/T back interface unit is faultyDescription
Depending on the network element, see either Nokia WCDMA RadioNetwork Controller Plug-in Unit Descriptions or Nokia Multimedia GatewayPlug-in Unit Descriptions in PDF format in NOLS for more information onplug-in units. For general instructions on how to install plug-in units, seeInstalling plug-in units in Installing the MGW and RNC.
Symptoms
BIE1C or BIE1T back interface unit is faulty.
Recoveryprocedures
Replacing a BIE1C or BIE1T back interface unit
Purpose
The following instructions explain how to replace BIE1C or BIE1T backinterface units.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 109 (179)
BIE1C/T back interface unit is faulty
Figure 10. BIE1C back interface unit
Locking
AllenkeyM2.5
AllenkeyM2.5
NIWU / NIP1SRBI-B
BIE1C
Front side
Rear side
DN02220536
110 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Figure 11. BIE1T back interface unit
Caution
Electrostatic discharge and incorrect installation and uninstallation candamage circuits or shorten their lifetime. To ensure proper functioning ofthe back interface units during their usual lifetime, take the followingprecautions before handling them.
. Before touching integrated circuits, ensure that you are working in anelectrostatic-free environment.
. Wear an ESD wrist strap or use another corresponding method todischarge static electricity in your body.
NIWU / NIP1AllenkeyM2.5
Locking
AllenkeyM2.5
SRBI-B
BIE1T
Front side
Rear side
DN02220575
DN70216177Issue 1-0 en
# Nokia Siemens Networks 111 (179)
BIE1C/T back interface unit is faulty
For more information on general environmental requirements, seeInstallation Site Requirements for MGW and RNC.
Note
Insert the back interface unit carefully. It is important to check that thelocking screws are closed properly, and that the back interface unit iswell in its place.
Before you start
Always check the interchangeability of the spare back interface unit beforechanging the unit. The interchangeability sticker is located in the frontpanel of the back interface unit after the C number. The interchangeabilitycode of the new back interface unit must be the same as or newer than theold back interface unit's code. If the interchangeability code of the newback interface unit is newer than the old unit's code, check the effects onthe interchangeability of the subrack and the other back interface units.
It is recommended that you maintain a log of spares so that you can traceany back interface unit at any time.
Note
Before removing or inserting a back interface unit, all the functionalunits in the plug-in unit (NI16P1) of the back interface unit must be inthe SE-NH state. For instructions, see Taking unit out of use.
Steps
1. Remove the cables from the front panel of the back interfaceunit
The functional units of the plug-in units must be in SE-NH statebefore removing the cables. The BIE1C unit has a coaxial cable andthe BIE1T a twisted pair cable on the front panel.
2. Unscrew locking screws on the front panel of the back interfaceunit
112 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Locking screws keep the back interface unit in its place. The lockingscrews are located on the upper and lower edge of the backinterface unit. See Figures BIE1C back interface unit and BIE1Tback interface unit.
3. Open the insertion/extraction lever on the front panel of theback interface unit
Insertion/extraction levers are locking clamps which secure the plug-in unit to the rack. The insertion/extraction lever is located on thelower edge of the back interface unit.
4. Carefully remove the back interface unit from the subrack
5. Carefully insert the spare back interface unit in its location
6. Close the insertion/extraction lever on the front panel of theback interface unit
7. Close the locking screws carefully
8. Insert cables back to the front panel of the back interface unit
The BIE1C unit has a coaxial cable and the BIE1T a twisted paircable on the front panel.
9. Set the functional units of the back interface unit to SE-OUworking state (USC)
ZUSC:<unit type>,<unit index>:SE;
10. Set the functional units of the back interface unit to TE workingstate (USC)
ZUSC:<unit type>,<unit index>:TE;
11. Check that the repair operation was successful by starting thetotal diagnosis of the unit (UDU)
ZUDU:<unit type>,<unit index>;
To output the results of the diagnostics.
ZUDH:<unit type>,<unit index>;
For more information, see Diagnostics and testing.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 113 (179)
BIE1C/T back interface unit is faulty
12. Set the unit to SP or WO working state, depending on theredundancy principle (USC)
ZUSC:<unit type>,<unit index>:SP|WO;
13. Check that the alarm disappears, if necessary (AAP)
ZAAP;
114 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
19 Fan tray is faultyDescription
An alarm is displayed if the fan tray (FTR) needs to be changed.
Depending on the network element, see either Nokia Multimedia GatewayPlug-in Unit Descriptions or Nokia WCDMA Radio Network ControllerPlug-in Unit Descriptions in PDF format in NOLS for information on fan tray(FTR/FTRA).
Symptoms
The alarm number 3013 is set when a fan tray is faulty.
Recoveryprocedures
Replacing fan tray
Purpose
Note that the equipment database does not recognise the fan tray, and itdoes not have working states.
The fan tray is located in a cabinet between subracks, see the figurebelow. See also Figure Co-ordinates of subracks and plug-in unit positionaddresses in Hardware Configuration Management.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 115 (179)
Fan tray is faulty
Figure 12. Fan tray
DN042269
Power supply unit
Fan tray and cable trough
116 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Caution
Electrostatic discharge and incorrect installation and uninstallation candamage circuits or shorten their lifetime. To ensure proper functioning ofthe fan trays during their usual lifetime, take the following precautionsbefore handling them.
. Before touching integrated circuits, ensure that you are working in anelectrostatic-free environment.
. Wear an ESD wrist strap or use another corresponding method todischarge static electricity in your body.
For more information on general environmental requirements, seeInstallation Site Requirements for MGW and RNC.
Note
Insert the fan tray carefully. It is important to check that the lockingscrews are closed properly, and that the fan tray is well in its place.
Before you start
You must change the fan tray within four minutes. The control cableattached to the fan tray can be removed only for four minutes at amaximum.
Caution
Pay special attention to removing and inserting the control cable.
The control cable is attached both to the subrack and to the FTR. Whenremoving the control cable, always remove it first from the subrack, andthen from the FTR. When inserting the control cable, always insert itfirst to the FTR, and then to the subrack.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 117 (179)
Fan tray is faulty
Always check the interchangeability of the spares before changing the fantray. The interchangeability sticker is located in the front panel of the fantray after the C number. The interchangeability code of the new fan traymust be the same as or newer than the old fan tray's code. If theinterchangeability code of the new fan tray is newer than the old unit'scode, check the effects on the interchangeability of the subrack and theplug-in units.
It is recommended that you maintain a log of spares so that you can traceany fan tray at any time.
Note
Replace the fan tray strictly in the order described in this procedure.Removing the control cable in the wrong order may cause a shortcircuit.
Steps
1. Remove the locking screws from the cable trough
2. Remove the locking screws from the fan tray
3. Remove the control cable from the subrack
The control cable is located behind the subrack, and it is attachedboth to the subrack and to the fan tray. Note that the control cablecan only be removed for four minutes at maximum.
After you have removed the cable from the subrack, the fan traystops. Note that the fan tray should not be stopped for more than fourminutes.
4. Remove the control cable from the fan tray
Note that the control cable can only be removed for four minutes atmaximum.
5. Pull the fan tray out of the subrack
For more information, see Figure Fan tray and Figure Co-ordinatesof subracks and plug-in unit position addresses in HardwareConfiguration Management.
6. Insert the new fan tray to the subrack
118 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
7. Connect the control cable behind the subrack to the fan tray
8. Connect the control cable behind the subrack to the subrack
9. Carefully close the locking screws in the front panel of the fantray
10. Carefully close the locking screws in the cable trough
11. Check that the alarm 3013 disappears and that there are no redLEDs on
Replacing fan tray during active traffic transfer
Purpose
Follow these instructions if you need to replace a fan tray while traffictransfer is active.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 119 (179)
Fan tray is faulty
Figure 13. Identification of fuses
FB5
FA5
DN042303
120 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Caution
Electrostatic discharge and incorrect installation and uninstallation candamage circuits or shorten their lifetime. To ensure proper functioning ofthe fan trays during their usual lifetime, take the following precautionsbefore handling them.
. Before touching integrated circuits, ensure that you are working in anelectrostatic-free environment.
. Wear an ESD wrist strap or use another corresponding method todischarge static electricity in your body.
For information on general environmental requirements, see InstallationSite Requirements for MGW and RNC.
Note
Insert the fan tray carefully. It is important to check that the lockingscrews are closed properly, and that the fan tray is well in its place.
Before you start
You must change the fan tray within four minutes. The control cableattached to the fan tray or fuses FA5 and FB5 can be removed only for fourminutes at maximum.
Caution
Pay special attention to removing and inserting the control cable. Thecontrol cable is attached to both the subrack and the FTR.
Always check the interchangeability of the spares before changing the fantray. The interchangeability sticker is located in the front panel of the fantray after the C number. The interchangeability code of the new fan traymust be the same as or newer than the old fan tray's code. If theinterchangeability code of the new fan tray is newer than the old unit'scode, check the effects on the interchangeability of the subrack and theplug-in units.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 121 (179)
Fan tray is faulty
It is recommended that you maintain a log of spares so that you can traceany fan tray at any time.
Note
Replace the fan tray strictly in the order described in this procedure.Removing the control cable in the wrong order may cause a shortcircuit.
Steps
1. Remove fuse FB5 of the PD20
Figure 14. Detaching fuse FB5
After the fuse FB5 is removed, the warning LED is lit. After the fuseis detached, alarm 3015 is displayed.
2. Move the cable trough
Remember to handle the cables carefully.
FB5FB5
DN042284
122 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Figure 15. Moving the cable trough
a. Remove the lower locking screws of the cable trough andloosen the upper ones. See insert 1 and 2 in Figure Moving thecable trough.
b. Loosen the locking screws of the subrack and move the cabletrough to the retaining screws of the subrack. See insert 3 inthe figure.
3. Remove the upper locking screws of the fan tray
4. Make sure that there is enough room to detach the control cableof the fan tray
5. Remove fuse FA5 of the PD20
DN042272
1
2
1
3
2
DN70216177Issue 1-0 en
# Nokia Siemens Networks 123 (179)
Fan tray is faulty
Figure 16. Detaching fuse FA5
Note
Detaching fuse FA5 shuts down the FTRA power supply. The newFTRA must be changed within four minutes at maximum (FTRA is shutdown during steps 5-10).
After removing the fuse, FTRA is shut down and the warning LED islit. Alarm 3013 is displayed.
6. Remove the control cable of the FTRA
The control cable is located behind the subrack and is attached toboth the subrack and the fan tray.
7. Pull the fan tray out of the subrack
Remove the rest of the bolts of the fan tray and pull the fan tray out.
8. Insert the new fan tray to the subrack
FA5
DN048669
124 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
9. Connect the control cable behind the subrack to the fan tray
10. Insert fuse FA5 back to its place
Figure 17. Inserting fuse FA5
After inserting fuse FA5, the warning LED is off and alarm 3015 isdisplayed.
After installing fuse FA5 back to its place, the FTRA is working again.
11. Carefully close the locking screws in the front panel of theFTRA
12. Move the cable trough back to its original place
13. Insert fuse FB5 back to its place
FA5FA5
DN048672
DN70216177Issue 1-0 en
# Nokia Siemens Networks 125 (179)
Fan tray is faulty
Figure 18. Inserting fuse FB5
After inserting fuse FB5, the warning LED is off and alarm 3013 isdisplayed.
14. Check that the alarm disappears and that there are no red LEDson
FB5
DN042296
126 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
20 Fan tray (FTRA-B) is faultyDescription
An alarm is displayed if the fan tray (FTRA-B) needs to be changed.
Depending on the network element, see either Nokia Multimedia GatewayPlug-in Unit Descriptions or Nokia WCDMA Radio Network ControllerPlug-in Unit Descriptions in PDF format in NOLS for information on fan tray(FTR/FTRA).
Symptoms
The alarm number 3013 is set when a fan tray is faulty.
Recoveryprocedures
Replacing fan tray
Purpose
Note that the equipment database does not recognise the fan tray, and itdoes not have working states.
The fan tray is located in a cabinet between subracks, see the figurebelow. See also Figure Co-ordinates of subracks and plug-in unit positionaddresses in Hardware Configuration Management.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 127 (179)
Fan tray (FTRA-B) is faulty
Figure 19. Fan tray
DN0629958
Fan tray and cable trough
128 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Caution
Electrostatic discharge and incorrect installation and uninstallation candamage circuits or shorten their lifetime. To ensure proper functioning ofthe fan trays during their usual lifetime, take the following precautionsbefore handling them.
. Before touching integrated circuits, ensure that you are working in anelectrostatic-free environment.
. Wear an ESD wrist strap or use another corresponding method todischarge static electricity in your body.
For more information on general environmental requirements, seeInstallation Site Requirements for MGW and RNC.
Note
Insert the fan tray carefully. It is important to check that the lockingscrews are closed properly, and that the fan tray is well in its place.
Before you start
You must change the fan tray within one minute. The control cableattached to the fan tray can be removed only for one minute at amaximum.
Always check the interchangeability of the spares before changing the fantray. The interchangeability sticker is located in the front panel of the fantray after the C number. The interchangeability code of the new fan traymust be the same as or newer than the old fan tray's code. If theinterchangeability code of the new fan tray is newer than the old unit'scode, check the effects on the interchangeability of the subrack and theplug-in units.
It is recommended that you maintain a log of spares so that you can traceany fan tray at any time.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 129 (179)
Fan tray (FTRA-B) is faulty
Caution
Do not remove the locking screws of the internal fan tray beforeremoving the control cable from the fan tray. The fan tray will fall outwhen the locking screws are opened.
Note
Replace the fan tray strictly in the order described in this procedure.
Steps
1. Open the front panel finger screw, pull the locking latches upand remove the front panel
Figure 20. Removing front panel
DN0629961
2
3
1
Locking latches
130 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
2. Loosen, but do not open fully, the locking screws of the internalfan tray
Figure 21. Loosening locking screws
3. Remove the control cable from the fan tray
Figure 22. Removing control cable
The control cable is located behind the subrack, and it is attachedboth to the subrack and to the fan tray. Note that the control cablecan only be removed for one minute at maximum.
DN0629973
DN0629985
DN70216177Issue 1-0 en
# Nokia Siemens Networks 131 (179)
Fan tray (FTRA-B) is faulty
After you have removed the cable from the subrack, the fan traystops. Note that the fan tray should not be stopped for more than oneminute.
4. Open the locking screws of the internal fan tray
5. Pull the internal fan tray out of the subrack
For more information, see Figure Fan tray and Figure Co-ordinatesof subracks and plug-in unit position addresses in HardwareConfiguration Management.
6. Insert the new internal fan tray to the subrack
7. Tighten the locking screws
8. Connect the control cable behind the subrack to the fan tray
9. Insert the front panel, close the locking latches and tighten thefront panel finger screw
10. Check that the alarm 3013 disappears and that there are no redLEDs on
Replacing air filter
Purpose
Follow these instructions if you need to replace the air filter of the fan tray.
Caution
Electrostatic discharge and incorrect installation and uninstallation candamage circuits or shorten their lifetime. To ensure proper functioning ofthe fan trays during their usual lifetime, take the following precautionsbefore handling them.
. Before touching integrated circuits, ensure that you are working in anelectrostatic-free environment.
. Wear an ESD wrist strap or use another corresponding method todischarge static electricity in your body.
132 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
For information on general environmental requirements, see InstallationSite Requirements for Nokia IPA2800 Network Elements.
Before you start
Note
Replace the air filter of the fan tray strictly in the order described in thisprocedure.
Steps
1. Open the front panel finger screw, pull the locking latches upand remove the front panel
Figure 23. Removing front panel
2. Pull the air filter out of the internal fan tray
DN0629961
2
3
1
Locking latches
DN70216177Issue 1-0 en
# Nokia Siemens Networks 133 (179)
Fan tray (FTRA-B) is faulty
Figure 24. Pulling air filter out
3. Insert the new air filter
4. Insert the front panel, close the locking latches and tighten thefront panel finger screw
DN0629997
134 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
21 Hard disk is faultyDescription
The following instructions explain how to replace a faulty hard disk so thatno data is lost. It is recommended to perform this task during low traffic.
Note
If both hard disks of OMU become faulty at the same time, you need torestore the data from the FDU drive. For detailed instructions, seeRestoring software from FDU if both OMU hard disks are faulty.
Symptoms
One of the following alarms is set when a hard disk is faulty: 1803 (SCSIMALFUNCTION), 2819 (SCSI DEFECT), 2823 (HARD DISK VERIFICATION
FAILURE), 2860 (DISK FAILURE), or 2861 (NO ACCESS TO DISK).
Recoveryprocedures
Checking if hard disk is faulty
Identifying hard disk failure in the booting phase of OMU or not in bootingphase.
1. In the booting phase of OMU
ZLP:P,POM
ZPKL
DN70216177Issue 1-0 en
# Nokia Siemens Networks 135 (179)
Hard disk is faulty
. Log starts with 'ncr' means problems with the SCSI driver(check at least the SCSI cabling to rule out the HW errors)
. Log with 'sense' text means problems with the SCSI device(meaning either hard disk or FDU drive)
. Logs with'discarding' texts means Shadows file system hasrejected the corresponding device and the disk is not includedin the mount
. Error code 0x3685 ENXIO: device does not exist
. Error code 0x3684 EIO: device is in catatonic state
. Any other error: please contact the Nokia Help Desk
Note
If the log states: 'SHF: TWO DIFFERENT DATABASE FOUND,UNABLE TO CONTINUE', there are two valid disks with differentcontents and the system cannot interpret which one to use. The otherhard disk is to be removed. You should check both disk file contentsand make decision accordingly.
2. Not in booting phase:
There are alarms set on the hard disk device. Hard disk is diagnosedand put to the state according the diagnostics result of phase:
SE = broken,
WO = OK,
TE = under diagnosis
Changing a hard disk
Before you start
If you have formatted disks at your disposal, performing this task is faster.For instructions on formatting the hard disks, see Initialising hard disks.
Steps
1. Change the state of the WDU into TE (IHE)
ZIHE::WDU,<device index>:TE;
136 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Note
When one of the hard disks is set to another state than WO-EX, thesystem locks the operating state of the remaining hard disk, thatmeans, additional working state flag LCK is displayed in the workingstate information of the other disk.
2. Change the state of the SCSI into SE (IHE)
The value for the SCSI bus index parameter is the same as theindex number of the faulty hard disk. If you changed WDU-0 to TEstate, then set SCSI-0 to SE state. If you changed WDU-1 to TEstate, then set SCSI-1 to SE state.
ZIHE::SCSI,<scsi bus index>:TE;
ZIHE::SCSI,<scsi bus index>:SE;
ZIHE::SCSI,<scsi bus index>:SE;
Note
If the disk is broken, the system has automatically separated the disk.
3. Remove the disk from its place
4. Check the strapping of the new disk
Make sure the strappings of the new disk correspond to those of thereplaced disk. For more information on strappings, see the SiteDocuments.
5. Put the new unit into its place and connect the power and signalcables
6. Change the state of SCSI into WO (IHE)
ZIHE::SCSI,<scsi bus index>:SE;
ZIHE::SCSI,<scsi bus index>:TE;
ZIHE::SCSI,<scsi bus index>:WO;
DN70216177Issue 1-0 en
# Nokia Siemens Networks 137 (179)
Hard disk is faulty
7. If the new disk is not formatted and initialised
Then
Format the disk (IWI)
Note
Formatting a disk is quite slow. It may take about 0.5 hours for a 9 GBWDU.
ZIWI::<disk device>;
Else
Initialise the WDU (IWK)
If you have a formatted disk at your disposal, initialise the disk.
ZIWK::<disk device>;
8. Diagnose the WDU in both OMU units (UDD)
Diagnosing the WDU in both OMUs
ZUDD:OMU,0:WDU,<device index>:<priority>;
ZUDD:OMU,1:WDU,:<device index>:<priority>;
ZUDD:<main unit identification>:<I/O device type>:<device index>:<priority>;
Expected outcome
Diagnosing takes maximum two minutes per unit.
Check the diagnostics result:
ZUDH:WDU,<device index>;
If the diagnosis result is OK, set the state of the WDU to WO-EX withthe following command:
ZIHE:OMU:WDU,<device index>:WO;
138 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Unexpected outcome
If the diagnosis result is not OK, the state of the WDU isautomatically changed to SE-OU.
9. Check if the mirroring update is proceeding (IHI)
Wait while the system updates the data from the other disk. You cancheck that updating is proceeding. The mirror updating (MIR)additional state flag shows this.
ZIHI::WDU;
Expected outcome
Mirroring takes several minutes.
When mirroring has been successfully completed, both the MIR andLCK flags are reset.
Unexpected outcome
If both disks are in the WO-EX state and the MIR flag is no longerdisplayed, but the LCK flag is still set, the mirroring was notsuccessfully completed, and the hard disk duplication is notfunctional. See Mirroring fails for further instructions.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 139 (179)
Hard disk is faulty
140 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
22 NEMU hard disk failsDescription
Because of the data duplication involved in mirror sets, the systemcontinues to function even when a member of the mirror set fails. If, for anyreason, either of hard disks fails or goes offline while in a raid level-1mirrored configuration, Windows 2000 continues to run from the mirroreddisk.
Recovering from hard disk failure when using software RAID1 is a verycomplicated process. Please follow the instructions carefully.
Note
Using OMU hard disks in NEMU is strictly forbidden, unless the disk iscompletely reformatted, including boot sector. OMU disk boot sector isincompatible with Windows 2000 file system and using OMU hard diskin NEMU will lead to failure in boot and loss of all data!
Symptoms
When either of the hard disks fail, a pop-up window with the text “Windows- FT Orphaning, a disk that is part of a fault-tolerant volume can no longerbe accessed” will appear to Windows desktop. Also, System Log will haveseveral events with event ID 15.
Recoveryprocedures
When you notice a disk failure, do the following:
1. Click OK in the pop-up window.
2. Log on to the system using an account with administrator privileges.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 141 (179)
NEMU hard disk fails
3. Open the Disk Management by clicking Start, Programs,Administrative Tools and then click Computer Management.
4. In the console tree under Storage, click Disk Management.
5. Check which disk has status Missing.
6. If Disk 0 is missing, proceed to the instruction: MCPC2(-A), Primaryoperating system disk has failed, disk 0 or MCP18(-B), Primaryoperating system disk has failed, disk 0, depending on the NEMUplug-in unit used.
7. If Disk 1 is missing, proceed to the instruction: MCPC2(-A),Secondary operating system disk has failed, disk 1 or MCP18(-B),Secondary operating system disk has failed, disk 1, depending onthe NEMU plug-in unit used.
142 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
23 MCPC2(-A), Primary operating systemdisk has failed, disk 0
Description
Primary operating system disk (disk 0) has failed. See the recoveryprocedure for recovering from this failure.
Note
Read the section NEMU hard disk fails before you start the recoveryprocedure.
This procedure provides instructions for troubleshooting the primaryoperating system disk of NEMU on the HDS/HDS9/HDS-A plug-in unit.
Symptoms
A pop-up window with the text “Windows - FT Orphaning, a disk that is partof a fault-tolerant volume can no longer be accessed” appears to theWindows desktop. Also, the System Log has several events with event ID15. In this case, disk 0 is missing.
Recoveryprocedures
Recovering from hard disk failure (primary operating system, disk 0)
Steps
1. Break mirrors using Disk Management
a. Right-click partition C on the missing disk (Disk 0).
b. Select the Remove Mirror option. Select Missing and click theRemove Mirror button. Then click the Yes button.
c. Right-click the partition E on the missing disk (Disk 0).
DN70216177Issue 1-0 en
# Nokia Siemens Networks 143 (179)
MCPC2(-A), Primary operating system disk has failed, disk 0
d. Select the Remove Mirror option. Select Missing and click theRemove Mirror button. Then click the Yes button.
e. Shut down the MCPC2/MCPC2-A by clicking the Start buttonand selecting the Shutdown option. From the drop downmenu, select the Shutdown option and click the OK button.
2. When NEMU has shut down (the text 'It is now safe to turn offyour computer' is displayed), remove the HDS/HDS9/HDS-Aplug-in unit with the WDU-0 (broken disk).
3. Remove the HDS/HDS9/HDS-A plug-in unit with the WDU-1(good disk).
4. Set the SCSI ID of WDU-1 (good disk) to the same place as therewas in theWDU-0 (broken disk).
5. Insert the HDS/HDS9/HDS-A plug-in unit with the old WDU-1 asWDU-0, that is, replace the WDU-0 with the WDU-1.
6. Replace the broken hard disk with the new one. Set the SCSI IDof the new hard disk to the same place as there was in the oldWDU-1 (broken disk).
7. Insert the HDS/HDS9/HDS-A plug-in unit with the replaced harddisk as WDU-1.
8. Restart the MCPC2/MCPC2-A by pressing the RST button in theMCPC2-A front panel.
9. When NEMU has started, log on to NEMU using an account withadministrator privileges.
10. Re-mirror the disks using Disk Management
a. Start Computer Management from Start, Programs,Administrative Tools.
b. In the console tree under Storage, click Disk Management.
c. If the Write Signature and Upgrade Disk wizard opens:
i. Click the Next button.
ii. Check disk 1 and click the Next button.
iii. If displayed again, check disk 1 and click the Nextbutton.
iv. Click the Finish button.
v. Go to step e).
144 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Note
Step e) is displayed online as step 5.
d. If the Write signature and Upgrade Disk wizard does not open:
i. Right-click Disk 1, and if Import Foreign Disks is visiblein the pop-up menu, select it. Click the OK button. Ifanother dialog opens, click the OK button.
ii. Right-click the Disk 1, and if Reactivate Disk is visible inthe pop-up menu, select it. Click the OK button. Wait forthe disk to go online.
iii. Delete all possible old partitions on Disk 1 by right-clicking the partition and selecting Delete Volume. Clickthe Yes button. Repeat this step as many times asneeded.
iv. Right-click Disk 1 and if Upgrade to Dynamic Disk optionis visible in the pop-up menu, select it. Click the OKbutton. Click Upgrade. Then click the Yes button twice.
e. Remove the missing hard disk by right-clicking Missing diskand selecting Remove Disk. In some cases, there can be twodisks identified as Disk 1. Ignore that, the extra Disk 1 willdisappear in the next reboot.
f. Right-click the C-partition on Disk 0, and then click Add Mirror.
g. In the Add Mirror window, select Disk 1 (if Disk 1 appearstwice, select the upper one) and click Add Mirror.
h. The Disk Management message box appears. Click the OKbutton. Regenerating of the C-drive begins.
i. Right-click the E-partition on Disk 0 and then click Add Mirror.
j. In the Add Mirror window, select Disk 1 and click Add Mirror.Regenerating of the E-drive begins.
k. Wait for the regenerating of both partitions to complete.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 145 (179)
MCPC2(-A), Primary operating system disk has failed, disk 0
146 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
24 MCPC2(-A), Secondary operating systemdisk has failed, disk 1
Description
Secondary operating system disk (disk 1) has failed. See the recoveryprocedure for recovering from this failure.
Note
Read the section NEMU hard disk fails before you start the recoveryprocedure.
This procedure provides instructions for troubleshooting the secondaryoperating system disk of NEMU on the HDS/HDS9/HDS-A plug-in unit.
Symptoms
A pop-up window with the text “Windows - FT Orphaning, a disk that is partof a fault-tolerant volume can no longer be accessed” appears to theWindows desktop. Also, the System Log has several events with event ID15. In this case, disk 1 is missing.
Recoveryprocedures
Recovering from hard disk failure (secondary operating system, disk 1)
Steps
1. Break mirrors using Disk Management:
a. Right-click partition C on the missing disk (Disk 1).
b. Select the Remove Mirror option. Select Missing and click theRemove Mirror button. Then click the Yes button.
c. Right-click partition E on the missing disk (Disk 1).
DN70216177Issue 1-0 en
# Nokia Siemens Networks 147 (179)
MCPC2(-A), Secondary operating system disk has failed, disk 1
d. Select the Remove Mirror option. Select Missing and click theRemove Mirror button. Then click the Yes button.
e. Shut down the MCPC2/MCPC2-A by clicking the Start buttonand selecting the Shut Down option. From the drop-downmenu, select Shut Down and click the OK button.
2. When NEMU has shut down (the text 'It is now safe to turn offyour computer' is displayed), remove the HDS/HDS9/HDS-Aplug-in unit with the WDU-1 (broken disk).
3. Replace the broken hard disk with a new one. Set the SCSI ID ofa new hard disk to the same place as there was in the old WDU-1 (broken disk).
4. Insert the HDS/HDS9/HDS-A plug-in unit with a replaced harddisk as WDU-1.
5. Restart the MCPC2/MCPC2-A by pressing the RST button in theMCPC2/MCPC2-A front panel.
6. When NEMU has started, log on to NEMU using an account withadministrator privileges.
7. Re-mirror the disks using Disk Management
a. Start Computer Management from Start, Programs,Administrative Tools.
b. In the console tree under Storage, click Disk Management.
c. If the Write Signature and Upgrade Disk wizard opens:
i. Click the Next button.
ii. Check disk 1 and click the Next button.
iii. If displayed again, check disk 1 and click the Nextbutton.
iv. Click the Finish button.
v. Go to step e).
Note
Step e) is displayed online as step 5.
d. If the Write Signature and Upgrade Disk wizard does not open:
148 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
i. Right-click Disk 1 and, if Import Foreign Disks is visiblein the pop-up menu, select it. Click the OK button. Ifanother dialog opens, click the OK button.
ii. Right-click Disk 1 and, if Reactivate Disk is visible in thepop-up menu, select it. Click the OK button. Wait for thedisk to go online.
iii. Delete all possible old partitions on Disk 1 by right-clicking the partition and selecting Delete Volume. Clickthe Yes button. Repeat this step as many times asneeded.
iv. Right-click Disk 1 and, if Upgrade to Dynamic Disk isvisible in the pop-up menu, select it. Click the OK button.Click Upgrade. Then click the Yes button twice.
e. Remove the missing hard disk by right-clicking Missing diskand selecting Remove Disk. In some cases, there can appeartwo disks identified as Disk 1. Ignore that, the extra Disk 1 willdisappear in the next reboot.
f. Right-click C-partition on Disk 0 and then click Add Mirror.
g. In the Add Mirror window, select Disk 1 (if Disk 1 appearstwice, select the upper one) and click Add Mirror.
h. The Disk Management message box appears. Click the OKbutton. Regenerating of C-drive begins.
i. Right-click E-partition on Disk 0 and then click Add Mirror.
j. In the Add Mirror window, select Disk 1 and click Add Mirror.Regenerating of E-drive begins.
k. Wait for the regenerating of both partitions to complete.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 149 (179)
MCPC2(-A), Secondary operating system disk has failed, disk 1
150 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
25 MCP18(-B), Primary operating systemdisk has failed, disk 0
Description
Primary operating system disk (disk 0) has failed. See the recoveryprocedure for recovering from this failure.
Note
Read the section NEMU hard disk fails before you start the recoveryprocedure.
This procedure provides instructions for troubleshooting the primaryoperating system disk of NEMU on the HDS-A plug-in unit.
Symptoms
A pop-up window with the text “Windows - FT Orphaning, a disk that is partof a fault-tolerant volume can no longer be accessed” appears to theWindows desktop. Also, the System Log has several events with event ID15. In this case, disk 0 is missing.
Recoveryprocedures
Recovering from hard disk failure (primary operating system, disk 0)
Steps
1. Break mirrors using Disk Management
a. Right-click partition C on the missing disk (Disk 0).
b. Select the Remove Mirror option. Select Missing and click theRemove Mirror button. Then click the Yes button.
c. Right-click the partition E on the missing disk (Disk 0).
DN70216177Issue 1-0 en
# Nokia Siemens Networks 151 (179)
MCP18(-B), Primary operating system disk has failed, disk 0
d. Select the Remove Mirror option. Select Missing and click theRemove Mirror button. Then click the Yes button.
e. Shut down the MCP18/-B by clicking the Start button andselecting the Shutdown option. From the drop down menu,select the Shutdown option and click the OK button.
2. When NEMU has shut down (the text 'It is now safe to turn offyour computer' is displayed), remove the HDS-A plug-in unitwith the WDU-0 (broken disk).
3. Remove the HDS-A plug-in unit with the WDU-1 (good disk).
4. Set the SCSI ID of WDU-1 (good disk) to the same place as therewas in the WDU-0 (broken disk).
5. Insert the HDS-A plug-in unit with the old WDU-1 as WDU-0, thatis, replace the WDU-0 with the WDU-1.
6. Replace the broken hard disk with the new one. Set the SCSI IDof the new hard disk to the same place as there was in the oldWDU-1 (broken disk).
7. Insert the HDS-A plug-in unit with the replaced hard disk asWDU-1.
8. Restart the MCP18/-B by pressing the RST button in theMCP18/-B front panel.
9. When NEMU has started, log on to NEMU using an account withadministrator privileges.
10. Re-mirror the disks using Disk Management
a. Start Computer Management from Start, Programs,Administrative Tools.
b. In the console tree under Storage, click Disk Management.
c. Right-click disk 1 and if Write Signature is visible in the pop-upmenu, select it. Click the OK button.
d. Delete all possible old partitions on disk 1 by right-clickingpartition and selecting Delete Volume or Delete Partition. Clickthe Yes button. Repeat this step as many times as needed.
e. Right-click disk 1 and if Upgrade to Dynamic Disk is visible inthe pop-up menu, select it. Click the OK button.
152 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
f. Remove the missing hard disk by right-clicking Missing diskand selecting Remove Disk. In some cases, there can be twodisks identified as Disk 1. Ignore that, the extra Disk 1 willdisappear in the next reboot.
g. Right-click the C-partition on Disk 0, and then click Add Mirror.
h. In the Add Mirror window, select Disk 1 (if Disk 1 appearstwice, select the upper one) and click Add Mirror.
i. The Disk Management message box appears. Click the OKbutton. Regenerating of the C-drive begins.
j. Right-click the E-partition on Disk 0 and then click Add Mirror.
k. In the Add Mirror window, select Disk 1 and click Add Mirror.Regenerating of the E-drive begins.
l. Wait for the regenerating of both partitions to complete.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 153 (179)
MCP18(-B), Primary operating system disk has failed, disk 0
154 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
26 MCP18(-B), Secondary operating systemdisk has failed, disk 1
Description
Secondary operating system disk (disk 1) has failed. See the recoveryprocedure for recovering from this failure.
Note
Read the section NEMU hard disk fails before you start the recoveryprocedure.
This procedure provides instructions for troubleshooting the secondaryoperating system disk of NEMU on the HDS-A plug-in unit.
Symptoms
A pop-up window with the text “Windows - FT Orphaning, a disk that is partof a fault-tolerant volume can no longer be accessed” appears to theWindows desktop. Also, the System Log has several events with event ID15. In this case, disk 1 is missing.
Recoveryprocedures
Recovering from hard disk failure (secondary operating system, disk 1)
Steps
1. Break mirrors using Disk Management:
a. Right-click partition C on the missing disk (Disk 1).
b. Select the Remove Mirror option. Select Missing and click theRemove Mirror button. Then click the Yes button.
c. Right-click partition E on the missing disk (Disk 1).
DN70216177Issue 1-0 en
# Nokia Siemens Networks 155 (179)
MCP18(-B), Secondary operating system disk has failed, disk 1
d. Select the Remove Mirror option. Select Missing and click theRemove Mirror button. Then click the Yes button.
e. Shut down the MCP18/-B by clicking the Start button andselecting the Shut Down option. From the drop-down menu,select Shut Down and click the OK button.
2. When NEMU has shut down (the text 'It is now safe to turn offyour computer' is displayed), remove the HDS-A plug-in unitwith the WDU-1 (broken disk).
3. Replace the broken hard disk with a new one. Set the SCSI ID ofa new hard disk to the same place as there was in the old WDU-1 (broken disk).
4. Insert the HDS-A plug-in unit with a replaced hard disk as WDU-1.
5. Restart the MCP18/-B by pressing the RST button in theMCP18/-B front panel.
6. When NEMU has started, log on to NEMU using an account withadministrator privileges.
7. Re-mirror the disks using Disk Management
a. Start Computer Management from Start, Programs,Administrative Tools.
b. In the console tree under Storage, click Disk Management.
c. Right-click Disk 1 and if Write Signature is visible in the pop-upmenu, select it. Click the OK button.
d. Delete all possible old partitions on Disk 1 by right-clickingpartition and selecting Delete Volume or Delete Partition. Clickthe Yes button. Repeat this step as many times as needed.
e. Right-click Disk 1 and if Upgrade to Dynamic Disk is visible inthe pop-up menu, select it. Click the OK button.
f. Remove the missing hard disk by right-clicking Missing diskand selecting Remove Disk. In some cases, there can appeartwo disks identified as Disk 1. Ignore that, the extra Disk 1 willdisappear in the next reboot.
g. Right-click C-partition on Disk 0 and then click Add Mirror.
h. In the Add Mirror window, select Disk 1 (if Disk 1 appearstwice, select the upper one) and click Add Mirror.
i. The Disk Management message box appears. Click the OKbutton. Regenerating of C-drive begins.
j. Right-click E-partition on Disk 0 and then click Add Mirror.
156 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
k. In the Add Mirror window, select Disk 1 and click Add Mirror.Regenerating of E-drive begins.
l. Wait for the regenerating of both partitions to complete.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 157 (179)
MCP18(-B), Secondary operating system disk has failed, disk 1
158 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
27 Hard disk (HDS-B) is faultyDescription
The following instructions explain how to replace a faulty OMU or NEMUhard disk on the HDS-B plug-in unit so that no data is lost. It isrecommended to perform this task during low traffic.
In the case of the HDS-B plug-in unit, OMU and NEMU hard disks arelocated on the same hard disk adapter. The positions of OMU and NEMUhard disks on the HDS-B are shown in figure 1.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 159 (179)
Hard disk (HDS-B) is faulty
Figure 25. HDS-B
When one of the hard disks on HDS-B is faulty, both NEMU and OMU unitsare affected. To be able to replace a faulty disk with a new one, the wholeHDS-B must be removed. Both OMU and NEMU disks on that plug-in-unitmust be tested when HDS-B is plugged in containing a replaced disk.
BACKPLANECONNECTORS
POWERCONNECTORS
SCSI BUSFLAT CABLES
SCSICONNECTORS
FRONT PANEL
HARD DISK
1
CN2
SCSIINTERFACE
1
CN2
SCSIINTERFACE
B
NEMU
A
OMU
1
2
3
4
5
HARD DISK
1 1
3 3
2 2
1
2
3
DN0639472
160 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Note
In this release, NEMU's HDD (hard disk drive) and OMU's WDU areboth located in the HDS-B plug-in unit. As NEMU is not a functional unitof the network element, its components must not be created asfunctional units into the Equipment database. This means that NEMU(the MCP18 plug-in unit) and NEMU HDD (in the HDS-B plug-in unit)are created as plug-in units only.
However, OMU WDU, also located in the HDS-B plug-in unit, must becreated as a functional unit too.
For more information on plug-in units and functional units, seeHardware configuration data management in Hardware ConfigurationManagement for MGW or RNC.
Because of the data duplication involved in NEMU mirror sets, the systemcontinues to function even when a member of the mirror set fails. If, for anyreason, either one of the hard disks fails or goes offline while in a raidlevel-1 mirrored configuration, Windows 2000 continues to run from themirrored disk. Recovering from hard disk failure when using softwareRAID1 is a very complicated process. Please follow the instructions onreplacing a faulty NEMU hard disk carefully.
See the following procedures for each case:
. A. OMU hard disk is faulty (WDU 0 or WDU 1)
. B. NEMU hard disk (hard disk 0) is faulty
. C. NEMU hard disk (hard disk 1) is faulty
Symptoms
. An OMU hard disk is faulty: one of the following alarms is set: 1803(SCSI MALFUNCTION), 2819 (SCSI DEFECT), 2823 (HARD DISKVERIFICATION FAILURE), 2860 (DISK FAILURE), or 2861 (NOACCESS TO DISK).
. One of the NEMU hard disks is faulty: a pop-up window with the text“Windows - FT Orphaning, a disk that is part of a fault-tolerantvolume can no longer be accessed” will appear to Windows desktop,and System Log will have several events with event ID 15.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 161 (179)
Hard disk (HDS-B) is faulty
Recoveryprocedures
A. OMU hard disk is faulty
Before you start
Note
If both hard disks of OMU become faulty at the same time, you need torestore the data from the FDU drive. For detailed instructions, seeRestoring software from FDU if both OMU hard disks are faulty.
If you have formatted disks at your disposal, performing this task is faster.For instructions on formatting the hard disks, see Initialising hard disks.
Steps
1. Check if the OMU hard disk is faulty
a. In the booting phase of OMU
ZLP:P,POM
ZPKL
. Log starts with 'ncr' means problems with the SCSIdriver (check at least the SCSI cabling to rule out the HWerrors)
. Log with 'sense' text means problems with the SCSIdevice (meaning either hard disk or FDU drive)
. Logs with 'discarding' texts means Shadows file systemhas rejected the corresponding device and the disk isnot included in the mount
. Error code 0x3685 ENXIO: device does not exist
. Error code 0x3684 EIO: device is in catatonic state
. Any other error: please contact the Nokia Help Desk
Note
If the log states: 'SHF: TWO DIFFERENT DATABASE FOUND,UNABLE TO CONTINUE', there are two valid disks with differentcontents and the system cannot interpret which one to use. The otherhard disk is to be removed. You should check both disk file contentsand make decision accordingly.
162 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
b. Not in booting phase:
There are alarms set on the hard disk device. Hard disk isdiagnosed and put to the state according the diagnostics resultof phase. If the hard disk is broken, it is put to the state SE-OU:
SE = broken
Other possibilities are:
WO = OK,
TE = under diagnosis
2. Change the state of the faulty WDU into TE (IHE)
ZIHE::WDU,<deviceindex>:TE;
Note
When one of the hard disks is set to another state than WO-EX, thesystem locks the operating state of the remaining hard disk, thatmeans, additional working state flag LCK is displayed in the workingstate information of the other disk.
3. Change the state of the SCSI into SE (IHE)
The value for the SCSI bus index parameter is the same as theindex number of the faulty hard disk. If you changed WDU-0 to TEstate, then set SCSI-0 to SE state. If you changed WDU-1 to TEstate, then set SCSI-1 to SE-NH state.
ZIHE::SCSI,<scsi bus index>:TE;
ZIHE::SCSI,<scsi bus index>:SE;
ZIHE::SCSI,<scsi bus index>:SE;
Note
If the disk is broken, the system has automatically separated the disk.
4. Remove the HDS-B plug-in unit from the subrack
5. Remove the broken OMU hard disk
DN70216177Issue 1-0 en
# Nokia Siemens Networks 163 (179)
Hard disk (HDS-B) is faulty
6. Check the strappings of the new disk
Make sure the strappings of the new disk correspond to those of thereplaced disk. For more information on strappings, see the SiteDocuments.
7. Put the new hard disk into its place on the HDS-B and connectthe power and signal cables
8. Reinstall HDS-B plug-in unit
9. Re-mirror the NEMU hard disks
a. In the pop-up window Fault tolerant disk cannot be accessed,click OK.
b. If you have not logged in, log in using an account withadministrator privileges.
c. Sart Disk Management by selecting Computer Managementfrom Start, Settings, Control Panel, Administrative Tools.
d. Right-click the mouse on top of the disk with the status Missingand select Reactivate Disk.
e. Disk mirror regenerating will start.
10. Change the state of SCSI into WO (IHE)
ZIHE::SCSI,<scsi bus index>:TE;
ZIHE::SCSI,<scsi bus index>:SE;
ZIHE::SCSI,<scsi bus index>:WO;
11. If the new disk is not formatted and initialised
Then
Format the disk (IWI)
Note
Formatting a disk is quite slow. It may take about 0.5 hours for a 9 GBWDU.
ZIWI::<disk device>;
Else
164 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Initialise the WDU (IWK)
If you have a formatted disk at your disposal, initialise the disk.
ZIWK::<disk device>;
12. Diagnose the WDU in both OMU units (UDD)
Diagnosing the WDU in both OMUs
ZUDD:OMU,0:WDU,<device index>:<priority>;
ZUDD:OMU,1:WDU,:<device index>:<priority>;
Expected outcome
Diagnosing takes a maximum of two minutes per unit.
Check the diagnostics result:
ZUDH:WDU,<device index>;
If the diagnosis result is OK, set the state of the WDU to WO-EX withthe following command:
ZIHE:OMU:WDU,<device index>:WO;
Unexpected outcome
If the diagnosis result is not OK, the state of the WDU isautomatically changed to SE-OU.
13. Check if the mirroring update is proceeding (IHI)
Wait while the system updates the data from the other disk. You cancheck that updating is proceeding. The mirror updating (MIR)additional state flag shows this.
ZIHI::WDU;
Expected outcome
Mirroring takes several minutes.
When mirroring has been successfully completed, both the MIR andLCK flags are reset.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 165 (179)
Hard disk (HDS-B) is faulty
Unexpected outcome
If both disks are in the WO-EX state and the MIR flag is no longerdisplayed, but the LCK flag is still set, the mirroring was notsuccessfully completed, and the hard disk duplication is notfunctional. See Mirroring fails for further instructions.
14. Check that NEMU disk mirroring is proceeding or has beencompleted
B. NEMU hard disk (hard disk 0) is faulty
Before you start
NEMU hard disk changing procedure differs depending on whether thefaulty disk is the primary operating disk (hard disk 0) or the secondaryoperating disk (hard disk 1). Follow these instructions if the broken disk isthe primary operating disk (hard disk 0).
Note
Using OMU hard disks in NEMU is strictly forbidden, unless the disk iscompletely reformatted, including boot sector. OMU disk boot sector isincompatible with Windows 2000 file system and using OMU hard diskin NEMU will lead to failure in boot and loss of all data!
Steps
1. Click OK in the pop-up window
2. Log on to the system using an account with administratorprivileges
3. Open the Disk Management by clicking Start, Programs,Administrative Tools and then click Computer Management
4. In the console tree under Storage, click Disk Management
5. Break mirrors using Disk Management
a. Right-click partition C on the missing disk (Disk 0).
b. Select the Remove Mirror option. Select Missing and click theRemove Mirror button. Then click the Yes button.
c. Right-click the partition E on the missing disk.
166 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
d. Select the Remove Mirror option. Select Missing and click theRemove Mirror button. Then click the Yes button.
e. Shut down the MCP18(-B) by clicking the Start button andselecting the Shutdown option. From the drop down menu,select the Shutdown option and click the OK button.
6. Check the strappings of the new disk
Make sure the strappings of the new disk correspond to those of thereplaced disk. For more information on strappings, see the SiteDocuments.
7. Replace NEMU hard disk 1 (good disk) with a new disk
a. Change the state of the OMU WDU into TE (IHE).
Change the state of the WDU on the HDS-B with the brokenNEMU hard disk into TE.
ZIHE::WDU,1:TE;.
Note
When one of the hard disks is set to another state than WO-EX, thesystem locks the operating state of the remaining hard disk, thatmeans, additional working state flag LCK is displayed in the workingstate information of the other disk.
b. Change the state of the OMU SCSI into SE-NH (IHE)
ZIHE::SCSI,1:TE;
ZIHE::SCSI,1:SE;
ZIHE::SCSI,1:SE;
c. When NEMU has shut down (the text 'It is now safe to turn offyour computer' is displayed), remove the HDS-B plug-in unitwith hard disk 1 (good disk).
d. Replace NEMU's hard disk with a new disk and set the SCSIID of the new hard disk 1 to be the same as that of the previoushard disk 1.
8. Install the HDS-B plug-in unit with the new hard disk 1 (newdisk)
a. Insert the HDS-B plug-in unit in hard disk 1 position.
b. Change the state of OMU SCSI in WO (IHE)
ZIHE::SCSI,1:SE;
ZIHE::SCSI,1:TE;
ZIHE::SCSI,1:WO;
DN70216177Issue 1-0 en
# Nokia Siemens Networks 167 (179)
Hard disk (HDS-B) is faulty
c. Set the state of OMU WDU-1 to WO-EX
ZIHE:OMU:WDU,1:WO;
9. Check if the mirroring update is proceeding (IHI)
Wait while the system updates the other disk. OMU hard disks haveto mirrored before the other one of the HDS-B units can bedisconnected.
You can check that updating is proceeding, the mirror updating (MIR)flag shows this.
ZIHI::WDU;
Expected outcome
Diagnosing takes a maximum of two minutes. When mirroring hasbeen successfully completed, both the MIR an LCK flags are reset.
Unexpected outcome
If both disks are on the WO-EX state and the MIR flag is no longerdisplayed, but the LCK flag is still set, mirroring was not successfullycompleted, and the hard disk duplication is not functional. SeeMirroring fails for further instructions.
10. Replace NEMU hard disk 0 (broken disk) with the previous harddisk 1 (good disk)
a. Change the state of the OMU WDU-0 into TE (IHE)
ZIHE::WDU,0:TE;.
Note
When one of the hard disks is set to another state than WO-EX, thesystem locks the operating state of the remaining hard disk, thatmeans, additional working state flag LCK is displayed in the workingstate information of the other disk.
b. Change the state of the OMU SCSI into SE-NH (IHE)
ZIHE::SCSI,0:TE;
ZIHE::SCSI,0:SE;
ZIHE::SCSI,0:SE;
168 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
c. Remove the HDS-B plug-in unit with the hard disk 0 (brokendisk).
d. Replace the broken NEMU hard disk (hard disk 0) with theprevious hard disk 1 disk and set the SCSI ID of the hard diskto be the same as that of the old hard disk 0 (broken disk).
11. Install the HDS-B plug-in unit in hard disk 0 position (replacedwith the previous hard disk 1)
a. Insert the HDS-B plug-in unit in hard disk 0 position.
b. Change the state of OMU SCSI ID into WO (IHE)
ZIHE::SCSI,0:SE;
ZIHE::SCSI,0:TE;
ZIHE::SCSI,0:WO;
c. Set the state of OMU WDU-0 to WO-EX
ZIHE:OMU:WDU,0:WO;
12. Check if the mirroring update is proceeding (IHI)
Wait while the system updates the other disk. You can check thatupdating is proceeding, the mirror updating (MIR) flag shows this.
ZIHI::WDU;
Expected outcome
Mirroring takes several minutes. When mirroring has beensuccessfully completed, both the MIR an LCK flags are reset.
Unexpected outcome
If both disks are on the WO-EX state and the MIR flag is no longerdisplayed, but the LCK flag is still set, mirroring was not successfullycompleted, and the hard disk duplication is not functional. SeeMirroring fails for further instructions.
13. Restart the MCP18(-B) by pressing the RST button in the MCP18(-B) front panel
14. When NEMU has started, log on to NEMU using an account withadministrator privileges
15. Re-mirror the disks using Disk Management
a. Start Computer Management from Start, Programs,Administrative Tools.
b. In the console tree under Storage, click Disk Management.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 169 (179)
Hard disk (HDS-B) is faulty
c. If the Write Signature and Upgrade Disk wizard opens:
i. Click the Next button.
ii. Check Disk 1 and click the Next button.
iii. If displayed again, check Disk 1 and click the Nextbutton.
iv. Click the Finish button.
v. Go to step e).
d. If the Write signature and Upgrade Disk wizard does not open:
i. Right-click Disk 1, and if Import Foreign Disks is visiblein the pop-up menu, select it. Click the OK button. Ifanother dialog opens, click the OK button.
ii. Right-click the Disk 1, and if Reactivate Disk is visible inthe pop-up menu, select it. Click the OK button. Wait forthe disk to go online.
iii. Delete all possible old partitions on Disk 1 by right-clicking the partition and selecting Delete Volume. Clickthe Yes button. Repeat this step as many times asneeded.
iv. Right-click Disk 1 and if Upgrade to Dynamic Disk optionis visible in the pop-up menu, select it. Click the OKbutton. Click Upgrade. Then click the Yes button twice.
e. Remove the missing hard disk by right-clicking Missing diskand selecting Remove Disk. In some cases, there can be twodisks identified as Disk 1. Ignore that, the extra Disk 1 willdisappear in the next reboot.
f. Right-click the C-partition on Disk 0, and then click Add Mirror.
g. In the Add Mirror window, select Disk 1 (if Disk 1 appearstwice, select the upper one) and click Add Mirror.
h. The Disk Management message box appears. Click the OKbutton. Regenerating of the C-drive begins.
i. Right-click the E-partition on Disk 0 and then click Add Mirror.
j. In the Add Mirror window, select Disk 1 and click Add Mirror.Regenerating of the E-drive begins.
k. Wait for the regenerating of both partitions to complete.
C. NEMU hard disk (hard disk1) is faulty
Before you start
NEMU hard disk changing procedure differs depending on whether thefaulty disk is the primary operating disk (hard disk 0) or the secondaryoperating disk (hard disk 1). Follow these instructions if the broken disk isthe secondary operating disk (hard disk 1).
170 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Note
Using OMU hard disks in NEMU is strictly forbidden, unless the disk iscompletely reformatted, including boot sector. OMU disk boot sector isincompatible with Windows 2000 file system and using OMU hard diskin NEMU will lead to failure in boot and loss of all data!
Steps
1. Click OK in the pop-up window
2. Log on to the system using an account with administratorprivileges
3. Open the Disk Management by clicking Start, Programs,Administrative Tools and then click Computer Management
4. In the console tree under Storage, click Disk Management
5. Break mirrors using Disk Management
a. Right-click partition C on the missing disk (Disk 1).
b. Select the Remove Mirror option. Select Missing and click theRemove Mirror button. Then click the Yes button.
c. Right-click the partition E on the missing disk.
d. Select the Remove Mirror option. Select Missing and click theRemove Mirror button. Then click the Yes button.
e. Shut down the MCP18(-B) by clicking the Start button andselecting the Shut Down option. From the drop down menu,select the Shut Down option and click the OK button.
6. Check the strappings of the new disk
Make sure the strappings of the new disk correspond to those of thereplaced disk. For more information on strappings, see the SiteDocuments.
7. Replace NEMU hard disk 1 (broken disk) with a new disk
a. Change the state of the OMU WDU into TE (IHE)
ZIHE::WDU,1:TE;.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 171 (179)
Hard disk (HDS-B) is faulty
Note
When one of the hard disks is set to another state than WO-EX, thesystem locks the operating state of the remaining hard disk, thatmeans, additional working state flag LCK is displayed in the workingstate information of the other disk.
b. Change the state of the OMU SCSI into SE-NH (IHE)
ZIHE::SCSI,1:TE;
ZIHE::SCSI,1:SE;
ZIHE::SCSI,1:SE;
c. When NEMU has shut down (the text 'It is now safe to turn offyour computer' is displayed), remove the HDS-B plug-in unitwith hard disk 1 (broken disk).
d. Replace the broken hard disk with a new disk and set the SCSIID of the new hard disk 1 to be the same as that of the previoushard disk 1.
8. Install HDS-B plug-in unit with hard disk 1
a. Insert the HDS-B plug-in unit in with the new disk in hard disk 1position.
b. Change the state of OMU SCSI-1 in WO (IHE)
ZIHE::SCSI,1:SE;
ZIHE::SCSI,1:TE;
ZIHE::SCSI,1:WO;
c. Set the state of OMU WDU-1 to WO-EX
ZIHE:OMU:WDU,1:WO;
9. Check if the mirroring update is proceeding (IHI)
Wait while the system updates the other disk. You can check thatupdating is proceeding, the mirror updating (MIR) flag shows this.
ZIHI::WDU;
Expected outcome
Diagnosing takes a maximum of two minutes. When mirroring hasbeen successfully completed, both the MIR an LCK flags are reset.
Unexpected outcome
172 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
If both disks are on the WO-EX state and the MIR flag is no longerdisplayed, but the LCK flag is still set, mirroring was not successfullycompleted, and the hard disk duplication is not functional. SeeMirroring fails for further instructions.
10. Restart the MCP18(-B) by pressing the RST button in the MCP18(-B) front panel
11. When NEMU has started, log on to NEMU using an account withadministrator privileges
12. Re-mirror the disks using Disk Management
a. Start Computer Management from Start, Programs,Administrative Tools.
b. In the console tree under Storage, click Disk Management.
c. If the Write Signature and Upgrade Disk wizard opens:
i. Click the Next button.
ii. Check Disk 1 and click the Next button.
iii. If displayed again, check Disk 1 and click the Nextbutton.
iv. Click the Finish button.
v. Go to step e).
d. If the Write signature and Upgrade Disk wizard does not open:
i. Right-click Disk 1, and if Import Foreign Disks is visiblein the pop-up menu, select it. Click the OK button. Ifanother dialog opens, click the OK button.
ii. Right-click the Disk 1, and if Reactivate Disk is visible inthe pop-up menu, select it. Click the OK button. Wait forthe disk to go online.
iii. Delete all possible old partitions on Disk 1 by right-clicking the partition and selecting Delete Volume. Clickthe Yes button. Repeat this step as many times asneeded.
iv. Right-click Disk 1 and if Upgrade to Dynamic Disk optionis visible in the pop-up menu, select it. Click the OKbutton. Click Upgrade. Then click the Yes button twice.
e. Remove the missing hard disk by right-clicking Missing diskand selecting Remove Disk. In some cases, there can be twodisks identified as Disk 1. Ignore that, the extra Disk 1 willdisappear in the next reboot.
f. Right-click the C-partition on Disk 0, and then click Add Mirror.
g. In the Add Mirror window, select Disk 1 (if Disk 1 appearstwice, select the upper one) and click Add Mirror.
DN70216177Issue 1-0 en
# Nokia Siemens Networks 173 (179)
Hard disk (HDS-B) is faulty
h. The Disk Management message box appears. Click the OKbutton. Regenerating of the C-drive begins.
i. Right-click the E-partition on Disk 0 and then click Add Mirror.
j. In the Add Mirror window, select Disk 1 and click Add Mirror.Regenerating of the E-drive begins.
k. Wait for the regenerating of both partitions to complete.
174 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Related Topics
Taking unit out of use
Instructions
Taking unit back into use
Plug-in unit is faulty
Working state change fails
Descriptions
Possible working state transitions
Working state change
Replacing plug-in unit with the same variant
Instructions
Plug-in unit is faulty
Replacing plug-in unit with newer variant
Instructions
Plug-in unit is faulty
DN70216177Issue 1-0 en
# Nokia Siemens Networks 175 (179)
Related Topics
Replacing CCPC2–A plug-in unit with CCP10 (OMU)
Instructions
Plug-in unit is faulty
Replacing ESA12 plug-in unit with ESA24
Instructions
Plug-in unit is faulty
Replacing MCPC2 plug-in unit with MCP18(-B)
Instructions
Plug-in unit is faulty
MCP18(-B) plug-in unit is faulty
Replacing MCPC2-A plug-in unit with MCP18(-B)
Instructions
Plug-in unit is faulty
MCP18(-B) plug-in unit is faulty
176 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Replacing interface units
Instructions
Plug-in unit is faulty
MCPC2(-A) plug-in unit is faulty
Instructions
Plug-in unit is faulty
MCP18(-B) plug-in unit is faulty
Instructions
Plug-in unit is faulty
PD20 plug-in unit is faulty
Instructions
Plug-in unit is faulty
PD30 plug-in unit is faulty
Instructions
Plug-in unit is faulty
DN70216177Issue 1-0 en
# Nokia Siemens Networks 177 (179)
Related Topics
ESA12 plug-in unit is faulty
Instructions
Plug-in unit is faulty
Replacing ESA12 plug-in unit with ESA24
ESA24 plug-in unit is faulty
Instructions
Plug-in unit is faulty
BIE1C/T back interface unit is faulty
Instructions
Plug-in unit is faulty
Fan tray is faulty
Instructions
Plug-in unit is faulty
178 (179) # Nokia Siemens Networks DN70216177Issue 1-0 en
Replacing Plug-in Units and Other Hardware Units
Fan tray (FTRA-B) is faulty
Instructions
Plug-in unit is faulty
Hard disk is faulty
Instructions
Increasing capacity of hard disk
Descriptions
Hard disks
Operating states of I/O devices
Hard disk (HDS-B) is faulty
Instructions
Increasing capacity of hard disk
Descriptions
Hard disks
Operating states of I/O devices
DN70216177Issue 1-0 en
# Nokia Siemens Networks 179 (179)