Top Banner
Features Your Spectroscopy Partner Handheld LIBS Research & Development Platform Lightweight, Handheld & Portable Light Element Detection Safe (No X-Ray Exposure) Rastering Beam or Mapping Point and Shoot Battery Operation High Accuracy and Precision Quick Results (1-2 Seconds) Touch Screen with Glove Operation Detects All Elements 19 Shea Way, Newark, DE 19713 • Tel: (302) 368-7824 • Web: www.bwtek.com Laser Induced Breakdown Spectroscopy (LIBS) Mobile Spectroscopy Solutions This product is available for OEM customers for developing custom analyzers for mobile applications. As a total solution provider, B&W Tek is actively seeking strategic, channel and OEM partners to enable them to address their custom applications and vertical markets.
3

Handheld LIBS Research & Development Platformsolutions.bwtek.com/acton/attachment/8353/f-00d3/1/-/-/-/-/Datasheet_LIBS.pdfLaser Induced Breakdown . Spectroscopy (LIBS) Mobile Spectroscopy

May 31, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Handheld LIBS Research & Development Platformsolutions.bwtek.com/acton/attachment/8353/f-00d3/1/-/-/-/-/Datasheet_LIBS.pdfLaser Induced Breakdown . Spectroscopy (LIBS) Mobile Spectroscopy

Features

Your Spectroscopy PartnerYour Spectroscopy Partner

Handheld LIBS Research & Development Platform

Lightweight, Handheld & PortableLight Element DetectionSafe (No X-Ray Exposure)Rastering Beam or MappingPoint and Shoot

Battery OperationHigh Accuracy and PrecisionQuick Results (1-2 Seconds) Touch Screen with Glove OperationDetects All Elements

19 Shea Way, Newark, DE 19713 • Tel: (302) 368-7824 • Web: www.bwtek.com

Laser Induced Breakdown Spectroscopy (LIBS)

Mobile Spectroscopy Solutions

This product is available for OEM customers for developing custom analyzers for mobile applications. As a total solution provider, B&W Tek is actively seeking strategic, channel and OEM partners to enable them to address their custom applications and vertical markets.

Page 2: Handheld LIBS Research & Development Platformsolutions.bwtek.com/acton/attachment/8353/f-00d3/1/-/-/-/-/Datasheet_LIBS.pdfLaser Induced Breakdown . Spectroscopy (LIBS) Mobile Spectroscopy

Mobile LIBS Applications

Sample LIBS Spectra

Minerals

Pharmaceutical Polymer

Diagnosis

Your Spectroscopy Partner

Mobile LIBS Solution

ZIBI Peipei : Dark_Subtracted

200 250 300 350 400

Wavelength (nm)

0

10000

20000

30000

40000

Rel

ativ

e In

tens

ity

Dolomite Fingernail

Advil Rubber Band

Industrial Laboratory

Chemistry- Catalyst & Impurity Control

Conservation- Pigment Analysis

Electronics-Particulate Analysis

Environment - Particulate Analysis

Food Safety & Quality

Geology - Impurity Distribution

Glass - Impurity Control

Medical Diagnostics

Mineral Analysis & Identification

Nuclear - Radioactive Element Analysis

Petroleum & Lubricants

Pharmaceutical - API ID & Tablet Analysis

Polymer Analysis - Plastic Recycling, Flame Retardant ID

RoHS Compliance

Safety & Security - Hazardous Materials ID

Mobile LIBS Solution

Compact SpectrometerFor “Real Time” Spectroscopy

System Integration with In-house Capabilities

World Class Software

In-house Applications Team

Superior PerformanceHandheld Integration

Chemometrics

Chemometrics/Methods/Calibration/Applications

Custom-built solutions for identification or quantitative analysis of pure materials & mixtures with our patent-pending chemometric/calibration engine

Match box size with powerful and fast multi-GW/cm2

plasma generation at an extremely high repetition rate

Advanced MicroLIBS Laser

Capable of multiplexing and real time spectroscopy with <20ns trigger/jitter and <100 picometer resolution; multiplexing capability for

integrating up to 16 spectrometers

Integrate into a handheld system with battery operation under Linux, Android or Window OS

In-house Material Identification Software-BWIDIn-house Quantitative Analysis Software-BWIQ

Quality & ComplianceMedical Device Engineering and ManufacturingISO 9001/13485 Certified SystemsFDA & CDRH Registration and Compliance CE Compliant Application of Six Sigma Methodologies Mock FDA Quality Systems Inspections Technique (QSIT) Extensive Quality Control Check Points Including InstallationQualification (IQ), Operational Qualification (OQ),Performance Qualification (PQ) and Software Verificationand Validation

A Total Solution Provider & Enabler of Mobile LIBS

Page 3: Handheld LIBS Research & Development Platformsolutions.bwtek.com/acton/attachment/8353/f-00d3/1/-/-/-/-/Datasheet_LIBS.pdfLaser Induced Breakdown . Spectroscopy (LIBS) Mobile Spectroscopy

Your Spectroscopy Partner Copyright 2016 B&W Tek · Doc-Rev: 400000118-C

Specifications Handheld LIBSLOD (Element Dependent) 10ppm - 10,000ppm

Accuracy 5 - 15%Display LED Color, Touchscreen, Glove Operable

GUI IntuitiveOperation Point & Shoot

Time to Result 1-2 Seconds (Typical)PC Connection Wi-Fi/USB

Battery Life 4 - 8 HoursOperating Temperature 0 - 40°C

Weight 3.5 - 5.5lbs

Dimensions (Approx) 11 x 3.5 x 11 inches

*Subject to Change

Research Tool (Out of Box)

Custom Analyzer (Application Development)

An Open Mobile LIBS Platform to Enable Real World Applications in Collaboration with Our Customers

B&W Tek Chemometric & Application Support

B&W Tek Software Programming

Model & CalibrationCoding in LOSCustom GUI

Spectra Collection Export to PC

OED/OEM Process

Research & Data Analysis

B&W Tek Handheld & Portable LIBS Platform

Custom LIBS Analyzer

19 Shea Way, Newark, DE 19713 (302) 368-7824