Top Banner
Scale Project No. Date BATSON & BROWN, INC. CONSULTING ENGINEERS GEORGE COUNTY DISTRICT 4 VOTING PRECINCT TITLE SHEET 46136-00 JANUARY 20, 2019 1"=10' Sheet No. 1 of 11 REV. 0 SCALE TITLE N.T.S. INDEX TITLE SHEET 1 NOTES & SCHEDULES 2 SITE LAYOUT 3 FLOOR PLAN 4 ELEVATION PLAN 5 FOUNDATION & PLUMBING 6 FOUNDATION DETAILS & NOTES 7 HVAC PLAN 8 ELECTRICAL PLAN 9 LIGHTING PLAN 10 TYPICAL DETAILS 11
11

GEORGE COUNTY DISTRICT 4 VOTING PRECINCTTITLE SHEET · a.contractor provided pre-engineered building & foundation plans b.concrete stained slab with plumbing stub-ups c.shop fabrication

Aug 10, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: GEORGE COUNTY DISTRICT 4 VOTING PRECINCTTITLE SHEET · a.contractor provided pre-engineered building & foundation plans b.concrete stained slab with plumbing stub-ups c.shop fabrication

Scale

Project N

o.

Date

BATS

ON

& B

ROW

N, I

NC.

CON

SULT

ING

ENGI

NEE

RSG

EO

RG

E C

OU

NT

Y D

IS

TR

IC

T 4

V

OT

IN

G P

RE

CIN

CT

TIT

LE

S

HE

ET

46

13

6-0

0

JA

NU

AR

Y 2

0, 2

01

9

1"=

10

'

Sheet N

o.

1 o

f 1

1

RE

V. 0

SCALE

TITLEN.T.S.

INDEX

TITLE SHEET 1

NOTES & SCHEDULES 2

SITE LAYOUT 3

FLOOR PLAN 4

ELEVATION PLAN 5

FOUNDATION & PLUMBING 6

FOUNDATION DETAILS & NOTES 7

HVAC PLAN 8

ELECTRICAL PLAN 9

LIGHTING PLAN 10

TYPICAL DETAILS 11

AutoCAD SHX Text
11267 OLD 63 SOUTH
AutoCAD SHX Text
LUCEDALE, MISSISSIPPI 39452
AutoCAD SHX Text
PHONE: (601) 947-8619
AutoCAD SHX Text
CONSTRUCTION PLANS OF PROPOSED
AutoCAD SHX Text
VOTING PRECINCT
AutoCAD SHX Text
GEORGE COUNTY BOARD OF SUPERVISORS
AutoCAD SHX Text
STATE OF MISSISSIPPI
AutoCAD SHX Text
DISTRICT 4, GEORGE COUNTY, MS
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
PROPOSED SITE LOCATION FOR VOTING PRECINCT
Page 2: GEORGE COUNTY DISTRICT 4 VOTING PRECINCTTITLE SHEET · a.contractor provided pre-engineered building & foundation plans b.concrete stained slab with plumbing stub-ups c.shop fabrication

GENERAL NOTES:

1. WORK REQUIRED UNDER THIS CONTRACT SHALL CONSIST OF THE CONTRACTOR PROVIDING A PRE-FABRICATED ENGINEERED METAL

BUILING, (DESIGNED BY A MISS. LICENSED PROFESSIONAL ENGINEER), TO INCLUDE ALL CONCRETE SLAB AND FOUNDATION WORK

NECESSARY FOR THE ERECTION OF THE METAL BUILDING.

2. ALL WORK SHALL BE IN ACCORDANCE WITH THE 2006 INTERNATIONAL BUILDING CODE (IBC) AND THE AMERICAN INSTITUTE OF STEEL

CONSTRUCTION (AISC, LATEST EDITION) AND SHALL BE MANUFACTURED TO THE FOLLOWING MINIMUM DESIGN REQUIREMENTS:

WIDTH (ft) = 40

LENGTH (ft) = 60

EAVE HEIGHT (ft) = 12

ROOF SLOPE (rise/12) = 2

DEAD LOAD (psf) = 2.5 + METAL BUILDING

COLLATERAL LOAD (psf) = 1.0

ROOF LIVE LOAD (psf) = 20.0

FRAME LIVE LOAD (psf) = 12.0

SNOW LOAD (psf) = 3.5

WIND SPEED (mph) = 125

WIND CODE = IBC 06

EXPOSURE = B

CLOSED/OPEN = C

IMPORTANCE WIND = 1.15

IMPORTANCE SEISMIC = 1.15

SEISMIC ZONE/DESIGN CATEGORY = B

SEISMIC COEFF (Fa*Ss) = 0.25

BASIC STRUCTURAL SYSTEM:

BUILDING FRAME SYSTEM WITH BRACED BENTS AND MOMENT RESISTING FRAMES

METAL BUILDING FOUNDATIONS AND SLAB IS TO BE DESIGNED NOT TO EXCEED A SOIL BEARING PRESSURE OF 1500 POUNDS

PER SQUARE FOOT.

3. SITE PREPARATION AND SLAB-ON-GRADE FILL MATERIAL WILL BE PROVIDED BY OWNER AND IS NOT A REQUIRED WORK ITEM.

4. CONTRACTOR WILL BE RESPONSIBLE FOR ANY EXCAVATION AND OR SHAPING OF MATERIAL IN CONSTRUCTION OF BUILDING

FOUNDATIONS, FOOTERS, AND SLABS ETC.

5. ALL COST IN PROVIDING FOUNDATIONS AND CONCRETE SLAB WORK AND PLUMBING AMENITIES (TO STUB UPS) SHALL BE AN

ABSORBED COST SUBSEQUENT TO PROVIDING THE 40'x60' PRE-ENGINEERED METAL BUILDING.

6. ALL DIMENSIONS SHOWN FOR THE OVERALL METAL BUILDING IS TO THE SHEETING STEEL LINE.

PROJECT DESCRIPTION/SCOPE OF WORK

Scale

Project N

o.

Date

BATS

ON

& B

ROW

N, I

NC.

CON

SULT

ING

ENGI

NEE

RSG

EO

RG

E C

OU

NT

Y D

IS

TR

IC

T 4

V

OT

IN

G P

RE

CIN

CT

NO

TE

S

46

13

6-0

0

JA

NU

AR

Y 2

0, 2

01

9

N.T

.S

.

Sheet N

o.

2 o

f 1

1

RE

V. 0

SCHEDULE OF WORK

I

BASE BID ITEM: 60' X40' PRE-ENGINEERED METAL BUILDING; 12' EAVE HEIGHT, 2:12 PITCH

WITH CONCRETE STAINED SLAB & APPURTENANCES

1 L.S.

APPURTENANCES TO INCLUDE

a. CONTRACTOR PROVIDED PRE-ENGINEERED BUILDING & FOUNDATION PLANS

b. CONCRETE STAINED SLAB WITH PLUMBING STUB-UPS

c. SHOP FABRICATION OF METAL BUILDING & DELIVERY

d. ON-SITE ERECTION & INSTALLATIONS

e.

INSULATION OF ROOF & SIDEWALLS (R-19 ROOF, R-13 SIDEWALLS)

f. ROOFING & SIDEWALL SHEETING

g.DOUBLE SWING, EXTERIOR DOORWAY & DOORS

h.SINGLE, EXTERIOR DOORWAY & DOORS

i.

SIDEWALL EXTERIOR WINDOW, INSULATED DOUBLE PANE (SIZED PER PLAN

LOCATION)

k. BRICK VENEER ON FRONT WALL

l. FLASHING & SOFFIT TRIM WORK

m. REAR PORCH SLAB & CANOPY

II

ALTERNATE BID ITEM: INTERIOR PARTITIONING WALLS, FRAMING, PLUMBING, &

FIXTURES

1 L.S.

APPURTENANCES TO INCLUDE

a.INTERIOR WALL FRAMING, INSULATION, FINISHES & TRIM WORK

b. PLUMBING & RESTROOM FIXTURES

c.CABINETS, COUNTERTOPS & KITCHEN FIXTURES

d.

INSULATED HANGING CEILING (EXCLUDING MECHANICAL ITEMS)

III

ALTERNATE BID ITEM: ELECTRICAL, LIGHTING, MECHANICAL & HVAC CLIMATE CONTROL

SYSTEM.

1 L.S.

APPURTENANCES TO INCLUDE

a.ELECTRICAL WIRING, PANELS, ENCLOSURES, SWITCHES & FIXTURES

b.

INTERIOIR LIGHTING (SWITCHES, LED FLUSH MOUNTED FIXTURES AND

APPURTENANCES)

c.

EXTERIOR LIGHTING (WALL PACKS), WEATHER PROOF 110 OUTLET & DISCONNECTS

d.

MECHANICAL- CENTRALIZED WATER HEATER (MIN. CAPACITY 40-GALLON), STOVE

HOOD TOP & VENTING

e.

TWO SINGLE-PHASE HEAT PUMP UNITS (TOTAL CAPICITY FOR 8 TONS BTU),

DUCTWORK, VENTING, RETURNS & APPURTENANCES.

AutoCAD SHX Text
THE FOLLOWING PLANS AND CONTRACT DOCUMENTS ARE INTENDED TO PRESENT WORK BEING REQUIRED FOR THE MANUFACTURE, DELIVERY, AND ERECTION OF A PREFABRICATED METAL BUILDING PROPOSED FOR THE OWNER’S USE AS A S USE AS A VOTING PRECINCT. THESE PLANS WILL SET FORTH THE OVERALL DIMENSIONS AND DESIRED FEATURES FOR THE BUILDING, FLOOR PLAN, AND INTERIOR PARTITIONING. (MINOR CHANGES MAY BE ALLOWED UPON APPROVAL BY THE OWNER). WHILE THE PLANS PRESENT AN OVERALL PLAN FOR EACH COMPONENT OF CONSTRUCTION, IT MAY NOT SET FORTH EXACT DETAILS AND/OR DIMENSIONS NECESSARY FOR THE CONSTRUCTION OF EACH ITEM. ALL WORK SET FORTH SHALL CONFORM TO THE GENERAL PRACTICES OF EACH TRADE REPRESENTED, INTERNATIONAL BUILDING CODE, 2006 VERSION, INTERNATIONAL MECHANICAL CODE, 2008 EDITION, AMERICAN INSTITUTION OF STEEL CONSTRUCTION, AND STATE/LOCAL CODE REQUIREMENTS. THE SCOPE OF WORK IS BEING SET FORTH AS THE FOLLOWING BID ITEMS: 1. BASE BID: 40'x60'x12' EAVE HEIGHT METAL BUILDING & APPURTENANCES – PROVIDE ALL MATERIALS, LABOR AND PROVIDE ALL MATERIALS, LABOR AND EQUIPMENT FOR A COMPLETED PRE-FABRICATED ENGINEERED METAL BUILDING ERECTED ON THE DESIGNATED SITE; INCLUDING CONCRETE FOUNDATIONS AND SLAB WITH APPURTENANCES AS SHOWN ON THE PLANS. 2. ALTERNATE BID ITEM: INTERIOR PARTITIONING WALLS, FRAMING, PLUMBING & FIXTURES – PROVIDE ALL PROVIDE ALL MATERIALS, LABOR AND EQUIPMENT FOR THE ERECTION OF ALL INTERIOR PARTITIONING WALLS, TO INCLUDE DOORWAYS, WINDOWS AND WALKWAY OPENINGS, INSULATION, AND FINISHES. CABINETS, COUNTERTOPS, AND BAR TOPS SHALL BE PROVIDED AS SHOWN ON THE PLANS FOR A COMPLETE KITCHEN AREA. RESTROOM STALLS, DOORWAYS AND LAVATORIES ARE TO BE INCLUDED UNDER THIS WORK ITEM AND SHALL COMPLY WITH ADA REQUIREMENTS. INSULATED HANGING CEILING SYSTEM SHALL BE MADE THROUGHOUT THE BUILDING'S INTERIOR WILL BE MADE UNDER THIS ITEM, WITH SUBSEQUENT HVAC ITEMS BEING INSTALLED UNDER SEPARATE WORK ITEMS. 3. ALTERNATE BID ITEM: ELECTRICAL, LIGHTING, MECHANICAL AND HVAC CLIMATE CONTROL SYSTEM – PROVIDE ALL PROVIDE ALL MATERIALS, LABOR AND EQUIPMENT FOR INSTALLATION OF THESE SYSTEMS IN CLOSE CONFORMANCE WITH PLAN (SCHEMATIC) LAYOUTS.
AutoCAD SHX Text
11267 OLD 63 SOUTH
AutoCAD SHX Text
LUCEDALE, MISSISSIPPI 39452
AutoCAD SHX Text
PHONE: (601) 947-8619
Page 3: GEORGE COUNTY DISTRICT 4 VOTING PRECINCTTITLE SHEET · a.contractor provided pre-engineered building & foundation plans b.concrete stained slab with plumbing stub-ups c.shop fabrication

Scale

Project N

o.

Date

BATS

ON

& B

ROW

N, I

NC.

CON

SULT

ING

ENGI

NEE

RSG

EO

RG

E C

OU

NT

Y D

IS

TR

IC

T 4

V

OT

IN

G P

RE

CIN

CT

SIT

E L

AY

OU

T

46

13

6-0

0

JA

NU

AR

Y 2

0, 2

01

9

N.T

.S

.

Sheet N

o.

3 o

f 1

1

RE

V. 0

AutoCAD SHX Text
WES HAVARD ROAD
AutoCAD SHX Text
HWY 26
AutoCAD SHX Text
VOTING PRECINCT
AutoCAD SHX Text
EXISTING POWER POLE
AutoCAD SHX Text
PROPOSED ELECTRICAL
AutoCAD SHX Text
SERVICE POLE
AutoCAD SHX Text
11267 OLD 63 SOUTH
AutoCAD SHX Text
LUCEDALE, MISSISSIPPI 39452
AutoCAD SHX Text
PHONE: (601) 947-8619
AutoCAD SHX Text
NORTH
Page 4: GEORGE COUNTY DISTRICT 4 VOTING PRECINCTTITLE SHEET · a.contractor provided pre-engineered building & foundation plans b.concrete stained slab with plumbing stub-ups c.shop fabrication

Scale

Project N

o.

Date

BATS

ON

& B

ROW

N, I

NC.

CON

SULT

ING

ENGI

NEE

RSG

EO

RG

E C

OU

NT

Y D

IS

TR

IC

T 4

V

OT

IN

G P

RE

CIN

CT

FL

OO

R P

LA

N

46

13

6-0

0

JA

NU

AR

Y 2

0, 2

01

9

N.T

.S

.

Sheet N

o.

4 o

f 1

1

RE

V. 0

AutoCAD SHX Text
MENS RESTROOM
AutoCAD SHX Text
WH
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
TYP. PLUMBING WALL 2X6 STUDS @ 16" O.C. W/ 5/8" WATERPROOF DRYWALL EACH FACE
AutoCAD SHX Text
LADIES RESTROOM
AutoCAD SHX Text
CLOSET
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
REFIG.
AutoCAD SHX Text
SINK
AutoCAD SHX Text
TYP. INTERIOR WALL 2X4 STUDS @ 16" O.C. W/ 5/8" DRYWALL EACH FACE
AutoCAD SHX Text
3068
AutoCAD SHX Text
3068
AutoCAD SHX Text
3068
AutoCAD SHX Text
3070
AutoCAD SHX Text
3070
AutoCAD SHX Text
3050
AutoCAD SHX Text
3050
AutoCAD SHX Text
3050
AutoCAD SHX Text
3070
AutoCAD SHX Text
3070
AutoCAD SHX Text
3050
AutoCAD SHX Text
3050
AutoCAD SHX Text
FUR OUT AROUND COLUMNS AS REQ'D.
AutoCAD SHX Text
TYP. EXTERIOR WALL 2X4 STUDS @ 16" O.C. W/ 5/8" DRYWALL EACH FACE
AutoCAD SHX Text
METAL SIDING (TYP. 4 SIDES)
AutoCAD SHX Text
COVERED PORCH ALONG FRONT OF BUILDING
AutoCAD SHX Text
NOTES: 1. STRUCTURAL METAL BUILDING COLUMN LOCATIONS AND RIGID FRAMES TO BE DETERMINED BY METAL BUILDING MANUFACTURER. 2. ALL FILL DIRT TO BE PROVIDED BY THE COUNTY. 3. ALL INTERIOR FLOORS SHALL BE FINISHED SMOOTH AND STAINED CONCRETE WITH SAWN JOINTING. 4. PRIMARY ELECTRICAL SHALL BE MADE FOR UNDERGROUND SERVICE FROM SREPA.
AutoCAD SHX Text
%%UFLOOR PLAN
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
INTERIOR
AutoCAD SHX Text
OVERHEAD CABINETS
AutoCAD SHX Text
PANEL
AutoCAD SHX Text
ELEC. STOVE &
AutoCAD SHX Text
HOOD UNIT
AutoCAD SHX Text
COUNTERTOP
AutoCAD SHX Text
OPEN COUNTERTOP
AutoCAD SHX Text
CABINETS &
AutoCAD SHX Text
HB
AutoCAD SHX Text
HB
AutoCAD SHX Text
HB
AutoCAD SHX Text
11267 OLD 63 SOUTH
AutoCAD SHX Text
LUCEDALE, MISSISSIPPI 39452
AutoCAD SHX Text
PHONE: (601) 947-8619
Page 5: GEORGE COUNTY DISTRICT 4 VOTING PRECINCTTITLE SHEET · a.contractor provided pre-engineered building & foundation plans b.concrete stained slab with plumbing stub-ups c.shop fabrication

Scale

Project N

o.

Date

BATS

ON

& B

ROW

N, I

NC.

CON

SULT

ING

ENGI

NEE

RSG

EO

RG

E C

OU

NT

Y D

IS

TR

IC

T 4

V

OT

IN

G P

RE

CIN

CT

EL

EV

AT

IO

N P

LA

N

46

13

6-0

0

JA

NU

AR

Y 2

0, 2

01

9

N.T

.S

.

Sheet N

o.

5 o

f 1

1

RE

V. 0

AutoCAD SHX Text
%%UBUILDING LEFT SIDE
AutoCAD SHX Text
%%UBUILDING RIGHT SIDE
AutoCAD SHX Text
%%UBUILDING FRONT SIDE
AutoCAD SHX Text
%%UBUILDING REAR SIDE
AutoCAD SHX Text
%%UTYP. BUILDING SECTION
AutoCAD SHX Text
TYP. INTERIOR WALL 2X4 STUDS @ 16" O.C. W/ 3/8" PANELING EACH FACE
AutoCAD SHX Text
TYP. INTERIOR WALL 2X4 STUDS @ 16" O.C. W/ 3/8" PANELING EACH FACE
AutoCAD SHX Text
TYP. PLUMBING WALL 2X6 STUDS @ 16" O.C. W/ 3/8" PANELING EACH FACE
AutoCAD SHX Text
FINISH FLOOR
AutoCAD SHX Text
EAVE HEIGHT EL. 12'-0" AFF
AutoCAD SHX Text
12
AutoCAD SHX Text
2
AutoCAD SHX Text
SUSPENDED CEILING
AutoCAD SHX Text
EXTERIOR WALL 2X4 STUDS @ 16" O.C. W/ 3/8" PANELING EACH FACE
AutoCAD SHX Text
GUTTER & DOWNSPOUT
AutoCAD SHX Text
METAL SIDING
AutoCAD SHX Text
GUTTER & DOWNSPOUT
AutoCAD SHX Text
GUTTER & DOWNSPOUT
AutoCAD SHX Text
GUTTER & DOWNSPOUT
AutoCAD SHX Text
GUTTER & DOWNSPOUT
AutoCAD SHX Text
GUTTER & DOWNSPOUT
AutoCAD SHX Text
GUTTER & DOWNSPOUT
AutoCAD SHX Text
GUTTER & DOWNSPOUT
AutoCAD SHX Text
GUTTER & DOWNSPOUT
AutoCAD SHX Text
GUTTER & DOWNSPOUT
AutoCAD SHX Text
GUTTER & DOWNSPOUT
AutoCAD SHX Text
GUTTER & DOWNSPOUT
AutoCAD SHX Text
HOSE BIBB REQ'D
AutoCAD SHX Text
HOSE BIBB REQ'D
AutoCAD SHX Text
HOSE BIBB REQ'D
AutoCAD SHX Text
DRAIN LINE VENTING THRU WALL WITH SCREENED COVER
AutoCAD SHX Text
ELECTRICAL METER BASE FOR UNDERGROUND SERVICE
AutoCAD SHX Text
110V WEATHER PROOF OUTLET & AC UNIT DISCONNECTS.
AutoCAD SHX Text
EXT. LIGHTING (WALL-PACK)
AutoCAD SHX Text
EXT. LIGHTING (WALL-PACK)
AutoCAD SHX Text
EXT. LIGHTING (WALL-PACK)
AutoCAD SHX Text
EXT. LIGHTING (WALL-PACK)
AutoCAD SHX Text
11267 OLD 63 SOUTH
AutoCAD SHX Text
LUCEDALE, MISSISSIPPI 39452
AutoCAD SHX Text
PHONE: (601) 947-8619
Page 6: GEORGE COUNTY DISTRICT 4 VOTING PRECINCTTITLE SHEET · a.contractor provided pre-engineered building & foundation plans b.concrete stained slab with plumbing stub-ups c.shop fabrication

Scale

Project N

o.

Date

BATS

ON

& B

ROW

N, I

NC.

CON

SULT

ING

ENGI

NEE

RSG

EO

RG

E C

OU

NT

Y D

IS

TR

IC

T 4

V

OT

IN

G P

RE

CIN

CT

FO

UN

DA

TIO

N &

P

LU

MB

IN

G P

LA

N

46

13

6-0

0

JA

NU

AR

Y 2

0, 2

01

9

N.T

.S

.

Sheet N

o.

6 o

f 1

1

RE

V. 0

AutoCAD SHX Text
MENS RESTROOM
AutoCAD SHX Text
LADIES RESTROOM
AutoCAD SHX Text
CLOSET
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
3068
AutoCAD SHX Text
3068
AutoCAD SHX Text
3068
AutoCAD SHX Text
3070
AutoCAD SHX Text
3070
AutoCAD SHX Text
3070
AutoCAD SHX Text
3070
AutoCAD SHX Text
COVERED PORCH ALONG FRONT OF BUILDING
AutoCAD SHX Text
%%UFOUNDATION & PLUMBING PLAN
AutoCAD SHX Text
CO
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text
2" STUB UP FOR LAVATORIES
AutoCAD SHX Text
2" PVC SCH-40 DRAIN
AutoCAD SHX Text
4" PVC CONDUIT FOR
AutoCAD SHX Text
COOLANT LINES
AutoCAD SHX Text
2" CLEAN-OUT
AutoCAD SHX Text
2" DRAIN
AutoCAD SHX Text
FOR SINK
AutoCAD SHX Text
2" FLOOR DRAIN
AutoCAD SHX Text
4" CLEAN-OUT
AutoCAD SHX Text
2" STUB UP FOR VENT
AutoCAD SHX Text
2" FLOOR DRAIN
AutoCAD SHX Text
4" STUB UP FOR TOILETS
AutoCAD SHX Text
2" STUB UP FOR URINAL
AutoCAD SHX Text
4" PVC SCH-40
AutoCAD SHX Text
SEWER DRAIN PIPE
AutoCAD SHX Text
1" PVC CONDENSATION DRAIN LINE
AutoCAD SHX Text
4" PVC CONDUIT FOR
AutoCAD SHX Text
COOLANT LINES
AutoCAD SHX Text
1" PVC CONDENSATION DRAIN LINE
AutoCAD SHX Text
HB
AutoCAD SHX Text
HB
AutoCAD SHX Text
HB
AutoCAD SHX Text
3/4" WATER
AutoCAD SHX Text
SUPPLY CONN.
AutoCAD SHX Text
FD
AutoCAD SHX Text
2" FLOOR DRAIN
AutoCAD SHX Text
11267 OLD 63 SOUTH
AutoCAD SHX Text
LUCEDALE, MISSISSIPPI 39452
AutoCAD SHX Text
PHONE: (601) 947-8619
Page 7: GEORGE COUNTY DISTRICT 4 VOTING PRECINCTTITLE SHEET · a.contractor provided pre-engineered building & foundation plans b.concrete stained slab with plumbing stub-ups c.shop fabrication

NOTE:

DRAIN DETAIL

TYPICAL ONE PER

RESTROOM

4 6

GENERAL NOTES:

PORCH GRADE

DETAIL

FOUNDATION TYPE "A"

INTERIOR COLUMNS

FOUNDATION TYPE "B"

END WALL & CORNERS

FOOTER SECTION "A"

TYPICAL PARAMETER WALLS

FOOTER SECTION "B"

TYPICAL COLUMN SUPPORTS

INTERIOR WALL FOOTER

TYPICAL ALL INTERIOR WALLS

Scale

Project N

o.

Date

BATS

ON

& B

ROW

N, I

NC.

CON

SULT

ING

ENGI

NEE

RSG

EO

RG

E C

OU

NT

Y D

IS

TR

IC

T 4

V

OT

IN

G P

RE

CIN

CT

FO

UN

DA

TIO

N D

ET

AIL

S &

N

OT

ES

46

13

6-0

0

JA

NU

AR

Y 2

0, 2

01

9

N.T

.S

.

Sheet N

o.

7 o

f 1

1

RE

V. 0

AutoCAD SHX Text
OF STEEL MAIN FRAME
AutoCAD SHX Text
8 - #6 BARS VERTICAL 42" X 9" L-BEND 16" X 16" DIA.
AutoCAD SHX Text
5 - #6 BARS 5' - 4" EA. @ 16" O.C. EA. WAY (TOP & BOTTOM)
AutoCAD SHX Text
SHEETING NOTCH AS REQ'D
AutoCAD SHX Text
POSITION OF ANCHOR BOLTS WITH OF FOOTER (SEE METAL BLDG. BASE PLATE DETAILS)
AutoCAD SHX Text
5 - #6 BARS 5' - 4" EA. @ 16" O.C. EACH WAY (TOP & BOTTOM)
AutoCAD SHX Text
FOOTER
AutoCAD SHX Text
FOOTER
AutoCAD SHX Text
2.67 CUBIC YARDS PER FOOTING
AutoCAD SHX Text
FOOTER
AutoCAD SHX Text
EDGE OF METAL BUILDING SIDE WALL
AutoCAD SHX Text
#6 - 10' HAIRPIN REQ'D
AutoCAD SHX Text
OF STEEL MAIN FRAME
AutoCAD SHX Text
8 - #6 BARS VERTICAL 42" X 9" L-BEND 16" X 16" DIA.
AutoCAD SHX Text
3 - #6 BARS 2' - 4" EA. @ 15" O.C. EA. WAY (TOP & BOTTOM)
AutoCAD SHX Text
SHEETING NOTCH AS REQ'D
AutoCAD SHX Text
POSITION OF ANCHOR BOLTS WITH OF FOOTER (SEE METAL BLDG. BASE PLATE DETAILS)
AutoCAD SHX Text
3 - #6 BARS 2' - 4" EA. @ 15" O.C. EACH WAY (TOP & BOTTOM)
AutoCAD SHX Text
FOOTER
AutoCAD SHX Text
FOOTER
AutoCAD SHX Text
0.67 CUBIC YARDS PER FOOTING
AutoCAD SHX Text
FOOTER
AutoCAD SHX Text
EDGE OF METAL BUILDING SIDE WALL
AutoCAD SHX Text
#6 - 10' HAIRPIN REQ'D
AutoCAD SHX Text
24"X24" CONT. GRADE BEAM AT PERIMETER OF SLAB FOR SLAB FOOTER REINF. W/ 3-#6 @ 9" SPACING TOP & 2-#6 @ 16" SPACING BOT.
AutoCAD SHX Text
24"X24" CONT. GRADE BEAM AT PERIMETER OF SLAB FOR SLAB FOOTER REINF. W/ 3-#6 @ 9" SPACING TOP & 2-#6 @ 16" SPACING BOT.
AutoCAD SHX Text
8" PERLIN OFFSET END WALL
AutoCAD SHX Text
POUR VOID AREA ABOVE SPREAD FOOTER AS PART OF SLAB.
AutoCAD SHX Text
STEEL FRAME LINE
AutoCAD SHX Text
STEEL FRAME LINE
AutoCAD SHX Text
POUR VOID AREA ABOVE SPREAD FOOTER AS PART OF SLAB.
AutoCAD SHX Text
1 1/2" SHEETING NOTCH
AutoCAD SHX Text
SIDING
AutoCAD SHX Text
18"
AutoCAD SHX Text
6" MIN.
AutoCAD SHX Text
COLUMN BEARING PAD
AutoCAD SHX Text
1 1/2" SHEETING NOTCH
AutoCAD SHX Text
SIDING
AutoCAD SHX Text
18" MIN.
AutoCAD SHX Text
18"
AutoCAD SHX Text
6" MIN.
AutoCAD SHX Text
8" Z GIRTS, A MINIMUM OF 5 REQ'D ON EACH WALL
AutoCAD SHX Text
2X4 WOOD STUD WALL & INSULATION
AutoCAD SHX Text
5" SLAB ON GRADE
AutoCAD SHX Text
COLUMN
AutoCAD SHX Text
3 - #4 CONT.
AutoCAD SHX Text
Z GIRTS, A MINIMUM OF 5 REQ'D ON EACH WALL
AutoCAD SHX Text
4 - #4 CONT.CONT.
AutoCAD SHX Text
ALL INTERIOR WALL FINISHES WILL INCLUDE DOORWAY AND WINDOW TRIMMING AND 4" BASE BOARD STAINED (COLOR TO BE DETERMINED BY OWNER.)
AutoCAD SHX Text
8"
AutoCAD SHX Text
2-#4 CONT.
AutoCAD SHX Text
5" SLAB ON GRADE REINF. W/6"x6" 10 GAUGE WIRE MESH & 6 MIL.VAPOR BARRIER.
AutoCAD SHX Text
2" SCHEDULE 40 PVC DRAIN PIPE
AutoCAD SHX Text
4" STRAINER
AutoCAD SHX Text
18" PER 1 FT. SLOPE TO DRAIN
AutoCAD SHX Text
1. SITE PREPARATION AND FILL MATERIAL FOR FOUNDATION PAD TO BE SITE PREPARATION AND FILL MATERIAL FOR FOUNDATION PAD TO BE PROVIDED BY OWNER. 2. ALL CONCRETE SHALL BE A MINIMUM OF 3000 PSI MIX. ALL CONCRETE SHALL BE A MINIMUM OF 3000 PSI MIX. 3. ALL PLUMBING TO BE SUPPLIED AND INSTALLED PRIOR TO POURING OF ALL PLUMBING TO BE SUPPLIED AND INSTALLED PRIOR TO POURING OF SLAB. 4. SEE SHEETS 4 AND 6 FOR SEWER AND WATER PLUMBING LOCATIONS SEE SHEETS 4 AND 6 FOR SEWER AND WATER PLUMBING LOCATIONS AND 6 FOR SEWER AND WATER PLUMBING LOCATIONS FOR SEWER AND WATER PLUMBING LOCATIONS REQUIRED UNDER "SLAB CONSTRUCTION WORK" 5. ALL FOUNDATIONS AND SLABS SHALL BE DESIGNED FOR A MAX SOIL ALL FOUNDATIONS AND SLABS SHALL BE DESIGNED FOR A MAX SOIL BEARING PRESSURE OF 1500 PSF.
AutoCAD SHX Text
18" PER 1 FT. SLOPE TO FRONT EDGE
AutoCAD SHX Text
11267 OLD 63 SOUTH
AutoCAD SHX Text
LUCEDALE, MISSISSIPPI 39452
AutoCAD SHX Text
PHONE: (601) 947-8619
Page 8: GEORGE COUNTY DISTRICT 4 VOTING PRECINCTTITLE SHEET · a.contractor provided pre-engineered building & foundation plans b.concrete stained slab with plumbing stub-ups c.shop fabrication

LEGEND

Scale

Project N

o.

Date

BATS

ON

& B

ROW

N, I

NC.

CON

SULT

ING

ENGI

NEE

RSG

EO

RG

E C

OU

NT

Y D

IS

TR

IC

T 4

V

OT

IN

G P

RE

CIN

CT

HV

AC

P

LA

N

46

13

6-0

0

JA

NU

AR

Y 2

0, 2

01

9

N.T

.S

.

Sheet N

o.

8 o

f 1

1

RE

V. 0

AutoCAD SHX Text
WH
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
ACOUSTIC TILES @ 9'-0" A.F.F. (TYP.)
AutoCAD SHX Text
2'x4' LAY IN LIGHT FIXTURES TYP. IN SUSPENDED METAL GRID W/ 2'x2' ACOUSTIC CEILING TYLES, TYP.
AutoCAD SHX Text
NOTE: HVAC HARD CEILING @ 9'-0"
AutoCAD SHX Text
2'x2' LAY IN LIGHT FIXTURE SEE ELECTRICAL DWGS. TYP. IN TOILET ROOMS
AutoCAD SHX Text
2'x2' LAY IN LIGHT FIXTURE SEE ELECTRICAL DWGS. TYP. IN TOILET ROOMS
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
WH
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
AIR DIFFUSER
AutoCAD SHX Text
RETURN INTAKES
AutoCAD SHX Text
EF
AutoCAD SHX Text
EF
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
11267 OLD 63 SOUTH
AutoCAD SHX Text
LUCEDALE, MISSISSIPPI 39452
AutoCAD SHX Text
PHONE: (601) 947-8619
AutoCAD SHX Text
%%UHVAC / CLIMATE CONTROL SYSTEM LAYOUT PLAN
AutoCAD SHX Text
NOTE: HVAC PLAN SHOWN AS GENERAL CONCEPT ONLY. CONTRACTOR SHALL HAVE HVAC & CLIMATE CONTROL SYSTEM DESIGNED AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS TO PROVIDE AN ANTICIPATED CAPACITY FOR 8 TONS BTU FOR THE FINISHED BUILDING.
Page 9: GEORGE COUNTY DISTRICT 4 VOTING PRECINCTTITLE SHEET · a.contractor provided pre-engineered building & foundation plans b.concrete stained slab with plumbing stub-ups c.shop fabrication

Scale

Project N

o.

Date

BATS

ON

& B

ROW

N, I

NC.

CON

SULT

ING

ENGI

NEE

RSG

EO

RG

E C

OU

NT

Y D

IS

TR

IC

T 4

V

OT

IN

G P

RE

CIN

CT

EL

EC

TR

IC

AL

P

LA

N

46

13

6-0

0

JA

NU

AR

Y 2

0, 2

01

9

N.T

.S

.

Sheet N

o.

9 o

f 1

1

RE

V. 0

LEGEND

GENERAL NOTES

1. ALL DATA AND COMMUNICATION

CIRCUITS ARE SINGLE RUNS BACK

TO THE DATA AND

COMMUNICATIONS BOARD.

2. ALL GENERAL DUTY

RECEPTACLES NOT TO EXCEED 20

AMPS PER CIRCUIT.

3. NO MORE THAN 6 GENERAL DUTY

RECEPTACLES PER CIRCUIT.

4. ALL ELECTRICAL SHALL CONFORM

TO THE LATEST EDITION OF THE

NEC (NATIONAL ELECTRIC CODE).

AutoCAD SHX Text
MENS RESTROOM
AutoCAD SHX Text
TYP. PLUMBING WALL 2X6 STUDS @ 16" O.C. W/ 5/8" WATERPROOF DRYWALL EACH FACE
AutoCAD SHX Text
LADIES RESTROOM
AutoCAD SHX Text
CLOSET
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
TYP. INTERIOR WALL 2X4 STUDS @ 16" O.C. W/ 5/8" DRYWALL EACH FACE
AutoCAD SHX Text
3068
AutoCAD SHX Text
3068
AutoCAD SHX Text
3068
AutoCAD SHX Text
3070
AutoCAD SHX Text
3070
AutoCAD SHX Text
3050
AutoCAD SHX Text
3050
AutoCAD SHX Text
3050
AutoCAD SHX Text
3070
AutoCAD SHX Text
3070
AutoCAD SHX Text
3050
AutoCAD SHX Text
3050
AutoCAD SHX Text
FUR OUT AROUND COLUMNS AS REQ'D.
AutoCAD SHX Text
TYP. EXTERIOR WALL 2X4 STUDS @ 16" O.C. W/ 5/8" DRYWALL EACH FACE
AutoCAD SHX Text
METAL SIDING (TYP. 4 SIDES)
AutoCAD SHX Text
COVERED PORCH ALONG FRONT OF BUILDING
AutoCAD SHX Text
%%UFLOOR PLAN
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
INTERIOR
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
PANEL
AutoCAD SHX Text
GFCI
AutoCAD SHX Text
HB
AutoCAD SHX Text
HB
AutoCAD SHX Text
HB
AutoCAD SHX Text
11267 OLD 63 SOUTH
AutoCAD SHX Text
LUCEDALE, MISSISSIPPI 39452
AutoCAD SHX Text
PHONE: (601) 947-8619
AutoCAD SHX Text
4
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
3
AutoCAD SHX Text
S
AutoCAD SHX Text
LAY-IN LIGHTING FIXTURE (2x4 FLUORESCENT)
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
SINGLE POLE SWITCH
AutoCAD SHX Text
3-WAY SWITCH
AutoCAD SHX Text
4-WAY SWITCH
AutoCAD SHX Text
220v OUTLET
AutoCAD SHX Text
110v OUTLET
AutoCAD SHX Text
110v GFCI OUTLET
AutoCAD SHX Text
DATA / COMMUNICATIONS
AutoCAD SHX Text
FLOOR JACK DATA COMMUNICATIONS
AutoCAD SHX Text
110v FLOOR PLUG
AutoCAD SHX Text
GFCI
Page 10: GEORGE COUNTY DISTRICT 4 VOTING PRECINCTTITLE SHEET · a.contractor provided pre-engineered building & foundation plans b.concrete stained slab with plumbing stub-ups c.shop fabrication

LEGEND

Scale

Project N

o.

Date

BATS

ON

& B

ROW

N, I

NC.

CON

SULT

ING

ENGI

NEE

RSG

EO

RG

E C

OU

NT

Y D

IS

TR

IC

T 4

V

OT

IN

G P

RE

CIN

CT

LIG

HT

IN

G P

LA

N

46

13

6-0

0

JA

NU

AR

Y 2

0, 2

01

9

N.T

.S

.

Sheet N

o.

10

o

f 1

1

RE

V. 0

AutoCAD SHX Text
ACOUSTIC TILES @ 9'-0" A.F.F. (TYP.)
AutoCAD SHX Text
2'x4' LAY IN LIGHT FIXTURES TYP. IN SUSPENDED METAL GRID W/ 2'x2' ACOUSTIC CEILING TYLES, TYP.
AutoCAD SHX Text
NOTE: HVAC HARD CEILING @ 9'-0"
AutoCAD SHX Text
2'x2' LAY IN LIGHT FIXTURE SEE ELECTRICAL DWGS. TYP. IN TOILET ROOMS
AutoCAD SHX Text
2'x2' LAY IN LIGHT FIXTURE SEE ELECTRICAL DWGS. TYP. IN TOILET ROOMS
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
AIR DIFFUSER
AutoCAD SHX Text
RETURN INTAKES
AutoCAD SHX Text
EF
AutoCAD SHX Text
EF
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
11267 OLD 63 SOUTH
AutoCAD SHX Text
LUCEDALE, MISSISSIPPI 39452
AutoCAD SHX Text
PHONE: (601) 947-8619
AutoCAD SHX Text
%%UREFLECTED CEILING & LIGHTING PLAN
AutoCAD SHX Text
NOTE: LIGHTING PLAN SHOWN AS GENERAL CONCEPT ONLY. CONTRACTOR SHALL SUPPLY AND INSTALL ALL INTERIOR LIGHTING, EXIT LIGHTING AND EXTERIOR LIGHTS PER MANUFACTURER'S RECOMMENDATIONS FOR AREAS OF COVERAGE AND COMPLY WITH THE NEI CODE REQUIREMENTS.
AutoCAD SHX Text
EXT. LIGHTING (WALL-PACK)
AutoCAD SHX Text
EXT. LIGHTING (WALL-PACK)
AutoCAD SHX Text
EXT. LIGHTING (WALL-PACK)
AutoCAD SHX Text
EXT. LIGHTING (WALL-PACK)
Page 11: GEORGE COUNTY DISTRICT 4 VOTING PRECINCTTITLE SHEET · a.contractor provided pre-engineered building & foundation plans b.concrete stained slab with plumbing stub-ups c.shop fabrication

NOTE:

WALL TYPE "B"

TYPICAL EXTERIOR WALL

(SIDES AND BACK)

WALL TYPE "C"

TYPICAL INTERIOR 2X4

PARTITIONING WALL

WALL TYPE "D"

TYPICAL INTERIOR 2X6

PLUMBING WALL

WALL TYPE "A"

TYPICAL EXTERIOR FRONT WALL

WITH WAINSCOT (INCL. AS BASE BID ITEM)

Scale

Project N

o.

Date

BATS

ON

& B

ROW

N, I

NC.

CON

SULT

ING

ENGI

NEE

RSG

EO

RG

E C

OU

NT

Y D

IS

TR

IC

T 4

V

OT

IN

G P

RE

CIN

CT

TY

PIC

AL

D

ET

AIL

S

46

13

6-0

0

JA

NU

AR

Y 2

0, 2

01

9

N.T

.S

.

Sheet N

o.

11

o

f 1

1

RE

V. 0

AutoCAD SHX Text
ALL INTERIOR WALL FINISHES WILL INCLUDE DOORWAY AND WINDOW TRIMMING AND 4" BASE MOLDING (OMIT BASE MOLDING IN LINER PANELS AREAS.)
AutoCAD SHX Text
INSULATION
AutoCAD SHX Text
EXTERIOR SHEETING
AutoCAD SHX Text
58" GYPSUM BOARD
AutoCAD SHX Text
58" GYPSUM BOARD
AutoCAD SHX Text
SOUND BATT INSULATION
AutoCAD SHX Text
2"X4" WOOD STUDS @ 16" O.C.
AutoCAD SHX Text
2"X4" WOOD STUDS @ 16" O.C.
AutoCAD SHX Text
BRICK WAINSCOT SHOWN- MIN. 42" HEIGHT (BASE BID ITEM)
AutoCAD SHX Text
SOUND BATT INSULATION
AutoCAD SHX Text
2"X6" WOOD STUDS @ 16" O.C.
AutoCAD SHX Text
8" Z-GIRTERS
AutoCAD SHX Text
INTERIOR WALL FINISH 58" GYPSUM BOARD
AutoCAD SHX Text
INSULATION
AutoCAD SHX Text
EXTERIOR SHEETING
AutoCAD SHX Text
2"X4" WOOD STUDS @ 16" O.C.
AutoCAD SHX Text
8" Z-GIRTERS
AutoCAD SHX Text
58" GYPSUM BOARD (WATER PROOF)
AutoCAD SHX Text
58" GYPSUM BOARD (WATER PROOF)
AutoCAD SHX Text
BRICK ROWLOCK (BASE BID ITEM)
AutoCAD SHX Text
INTERIOR WALL FINISH 58" GYPSUM BOARD
AutoCAD SHX Text
11267 OLD 63 SOUTH
AutoCAD SHX Text
LUCEDALE, MISSISSIPPI 39452
AutoCAD SHX Text
PHONE: (601) 947-8619