Top Banner
Handling Instruction For Solderless PCB mount Connectors HI_016 Rosenberger Hochfrequenztechnik GmbH & Co. KG P.O.Box 1260 D-84526 Tittmoning Germany www.rosenberger.de Tel. : +49 8684 18-0 Email : [email protected] Page 1 / 2 RF_35/09.14/6.2 Dieses Dokument ist urheberrechtlich geschützt This document is protected by copyright Rosenberger Hochfrequenztechnik GmbH & Co. KG 1) This handling instruction is valid for all Rosenberger solderless PCB mount connectors. Please note the recommended footprint in the technical datasheet of the used solderless PCB mount connector. Figure 1 shows for example the recommended footprint MB_389 for explanation. Please note the form and position tolerances of the 1.3 mm diameter holes. The more accurate the tolerances the better the prepositioning of the solderless connector. In optimal cases the positioning of the center contact on the contact area (see detail Z) should be ok due to the prepositioning through the dowel pins but it is still recommended to check the positioning of the center contact under a microscope. Figure 1: PCB Layout MB_389 2) Figure 2 shows the footprint MB_389 for one connector of the Test PCB for solderless PCB connectors (PCB-K2702) and Figure 3 shows the PCB side of a solderless PCB connector with the dowel pins. Place the solderless PCB connector on the PCB and tighten the screws slightly to the threaded plate on the bottom side of the PCB with the enclosed screws. Figure 2: detail of PCB-K2702 (Test PCB) Figure 3: PCB side of solderless connector with dowel pins
2

For Solderless PCB mount Connectors HI 016For Solderless PCB mount Connectors HI_016 F. Reiner Rosenberger Hochfrequenztechnik GmbH & Co. KG P.O.Box 1260 D-84526 Tittmoning Germany

Aug 13, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: For Solderless PCB mount Connectors HI 016For Solderless PCB mount Connectors HI_016 F. Reiner Rosenberger Hochfrequenztechnik GmbH & Co. KG P.O.Box 1260 D-84526 Tittmoning Germany

Handling Instruction

For Solderless PCB mount Connectors HI_016

Rosenberger Hochfrequenztechnik GmbH & Co. KG

P.O.Box 1260 D-84526 Tittmoning Germany

www.rosenberger.de

Tel. : +49 8684 18-0

Email : [email protected]

Page

1 / 2

RF

_35/0

9.1

4/6

.2

Die

ses D

okum

ent is

t urh

eberr

echtlic

h g

eschütz

t ●

Th

is d

ocum

ent is

pro

tecte

d b

y c

opyrig

ht

● R

osenberg

er

Hochfr

equenzte

chnik

Gm

bH

& C

o. K

G

1) This handling instruction is valid for all Rosenberger solderless PCB mount connectors. Please note the recommended footprint in the technical datasheet of the used solderless PCB mount connector.

Figure 1 shows for example the recommended footprint MB_389 for explanation. Please note the form and position tolerances of the 1.3 mm diameter holes. The more accurate the tolerances the better the prepositioning of the solderless connector. In optimal cases the positioning of the center contact on the contact area (see detail Z) should be ok due to the prepositioning through the dowel pins but it is still recommended to check the positioning of the center contact under a microscope.

Figure 1: PCB Layout MB_389

2) Figure 2 shows the footprint MB_389 for one connector of the Test PCB for solderless PCB connectors (PCB-K2702) and Figure 3 shows the PCB side of a solderless PCB connector with the dowel pins.

Place the solderless PCB connector on the PCB and tighten the screws slightly to the threaded plate on the bottom side of the PCB with the enclosed screws.

Figure 2: detail of PCB-K2702 (Test PCB)

Figure 3: PCB side of solderless connector with dowel

pins

Page 2: For Solderless PCB mount Connectors HI 016For Solderless PCB mount Connectors HI_016 F. Reiner Rosenberger Hochfrequenztechnik GmbH & Co. KG P.O.Box 1260 D-84526 Tittmoning Germany

Handling Instruction

For Solderless PCB mount Connectors HI_016

Rosenberger Hochfrequenztechnik GmbH & Co. KG

P.O.Box 1260 D-84526 Tittmoning Germany

www.rosenberger.de

Tel. : +49 8684 18-0

Email : [email protected]

Page

2 / 2

RF

_35/0

9.1

4/6

.2

Die

ses D

okum

ent is

t urh

eberr

echtlic

h g

eschütz

t ●

Th

is d

ocum

ent is

pro

tecte

d b

y c

opyrig

ht

● R

osenberg

er

Hochfr

equenzte

chnik

Gm

bH

& C

o. K

G

3) Figure 4 shows the mounted solderless PCB connector on the Test PCB. Check the positioning of the center contact on the contact are under a microscope. Figure 5, Figure 6 and Figure 7 shows the in

Figure 4 marked detail for different positioning of the solderless PCB connector.

Make sure that the center contact is positioned as centrally as possible (as shown in Figure 7, green frame) to get a good result.

If the positionig is bad (Figure 5, red frame) or moderate (Figure 6, orange frame), loosen the screws

slightly and reposition the solderless PCB connector to reach a position like shown in Figure 7 and thighten the screws slightly.

Figure 4: mounted solderless connector on PCB with marked detail

Figure 5: Detail - bad positioning

Figure 6: Detail - moderate

positioning

Figure 7: Detail - good positioning

4) Thighten the screws with a torque of 0.20 Nm to 0.30 Nm. Please note that it is possible to deviate from this recommendation depending on the PCB material.

Draft Date Approved Date Rev. Engineering change number Name Date

F. Reiner 27.11.18 H. Babinger 11.11.19 a01 19-0008 G. Schiele 11.11.19

While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our products, we reserve the right to make changes judged to be necessary.